Nothing Special   »   [go: up one dir, main page]

LANGER-logo

Sistema de desenvolvemento de inmunidade LANGER E1 Set

LANGER-E1-Set-Immunity-Development-System

Breve descrición

The E1 is a set of EMC tools used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes ofburst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness ofthe measures taken. The E1 test set-up is small and fits easily on a developer’s desk. The E1 set user manual describes EMC mechanisms and provides detailed descriptions of basic measuring strategies for interference suppression in printed circuit boards. The E1 set includes a generator to generate burst and ESD disturbances.

Alcance de entrega

  • 1x SGZ 21, xerador de explosión
  • 1x BS 02, fonte de campo magnético
  • 1x BS 05D, fonte de campo magnético
  • 1x ES 00, fonte E-Field
  • 1x ES 02, fonte E-Field
  • 1x ES 08D, fonte E-Field
  • 1x E1 acc, accesorios
  • 1x caso E1, carcasa do sistema
  • 1x S21, sensor óptico (10 Mbps)
  • 1x BS 04DB, fonte de campo magnético
  • 1x BS 05DU, fonte de campo magnético
  • 1x ES 01, fonte E-Field
  • 1x ES 05D, fonte E-Field
  • 1x MS 02, sonda de campo magnético
  • 1x NT FRI EU, Unidade de alimentación
  • 1x E1 m, E1 Set Manual de usuario

Parámetros técnicos

S21 óptica sensor  
Rango de transmisión DC…10 Mbps
Optical fibre connector Ø 2.2 mm
Vol. Subministracióntage (3-5) V
Entrada actual 10 mA
SGZ 21 rebentar Xerador  
Pulse parameter  
Tempo de subida ca. 2 ns
Tail time ca. 10 ns
Valores pico ca. 0…1500 V
Entrada óptica  
Fibra óptica 2.2 mm
Máx. frecuencia 5 MHz
Min. pulse width 100 ns
Vol. Subministracióntage 12 V / 200 mA
Sizes (L x W x H) (154 x 100 x 62) mm

Principios de medición

LANGER-E1-Set-Immunity-Development-System-fig-1

Application with BS 04 DB

LANGER-E1-Set-Immunity-Development-System-fig-2

Ámbito de entrega E1

LANGER-E1-Set-Immunity-Development-System-fig-3

Explotou view debuxo E1

LANGER-E1-Set-Immunity-Development-System-fig-4

Application with MSA 02 magnetic field probe from the S2 set

LANGER-E1-Set-Immunity-Development-System-fig-5

Langer EMV-Technik GmbH
www.langer-emv.com
+49 351 430093 0
sales@langer-emv.de

Documentos/Recursos

Sistema de desenvolvemento de inmunidade LANGER E1 Set [pdf] Guía de instalación
SGZ 21, BS 02, BS 05D, ES 00, ES 02, ES 08D, S21, BS 04DB, BS 05DU, ES 01, ES 05D, MS 02, NT FRI EU, E1 Set Sistema de desenvolvemento de inmunidade, Set E1, Sistema de desenvolvemento de inmunidade, Sistema de desenvolvemento

Referencias

Deixa un comentario

O teu enderezo de correo electrónico non será publicado. Os campos obrigatorios están marcados *