Specifications

  • Product Name: BEL6/BENL5/BEL8/BENL8 Roomside Series Fan/Light
  • Manufacturer: Broan NuTone LLC
  • Operation: Fan and light can be operated separately
  • Installation Height: At least 8 feet (2.4 m) above the floor
  • Power Source: Electric

Product Usage Instructions

  1. Use the unit only as intended by the manufacturer.
  2. Ensure power is switched off before servicing or cleaning.
  3. Installation and electrical work should be done by qualified personnel.
  4. Adequate ventilation is necessary for proper operation.
  5. Avoid damaging electrical wiring when cutting into walls or ceilings.

Installation

Follow these steps for proper installation of the fan/light Munit:

  1. Ensure the power source is switched off.
  2. Follow all applicable codes and standards duringN installation.
  3. Ducted fans must be vented outdoors.
  4. Ensure proper grounding of the unit.

Operation
To operate the fan/light:

  1. Use an on/off switch to control the fan and light separately.
  2. Refer to the manufacturer’s catalog for compatible wall  controls and accessories.

FAQ

Q: Can this fan/light be installed in a cooking area?
A: No, it is not recommended to install this unit above or inside a cooking area.

BEL6/BENL5/BEL8/BENL8
Roomside Series Fan/Light

READ AND SAVE THESE INSTRUCTIONS

For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States – Broan-NuTone.com 800-558-1711. In Canada – Broan-NuTone.ca 800-567-3855.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  6. Ducted fans must always be vented to the outdoors.
  7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit (ceiling installation only).
  8. This unit must be grounded.
  9. Do not use this fan with any solid-state speed control device.
  10. Do not use replacement parts that have not been recommended by Broan NuTone LLC.
  11. If the fan makes excessive noise or if there is unusual noise or smells of smoke. Disconnect power supply and contact customer service.
  12. The wearing of safety glasses and gloves is recommended when installing, maintaining or cleaning the unit to reduce the risk of injury that could be caused by the presence of thin metal and/or moving parts.

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. Install the fan at least 8 feet (2.4 m) above the floor.
  3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
  4.  Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE

TO CLEAN THE GRILLE: Remove the grille and grille trim. Plastic parts can be cleaned with mild detergent, such as dishwashing liquid. Dry with a soft cloth. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS OR SCOURING POWDERS.
TO CLEAN INTERIOR OF THE UNIT: Once the grille and grille trim are removed, gently vacuum interior of the unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).

OPERATION
Use an on/off switch to operate the fan/light. The fan and light can be operated separately. Use appropriate 2-function wall control. Refer to Broan-NuTone catalog for a complete line of accessories/controls to effectively adapt these fans to your requirements.

Broan-NuTone-BEL6-Room-Side-Fan-Light (2)IMPORTANT – The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow. Broan-NuTone-BEL6-Room-Side-Fan-Light (3)OPTION – To mount housing anywhere between ceiling framing: Use optional Hanger Bar Kit (sold separately from local distributors or website). Follow mounting instructions included with kit.

QUICK START GUIDE

  1. Remove from packaging. Remove blower assembly and wiring panel. Broan-NuTone-BEL6-Room-Side-Fan-Light (4)
  2. Mount housing.
    Choose one option to mount housing to ceiling structure: Broan-NuTone-BEL6-Room-Side-Fan-Light (5)Other options:
    • Hanger bars (sold separately Model Number MHB4)
    • Flange Install (see Installation video) Broan-NuTone-BEL6-Room-Side-Fan-Light (6)

Choose one option to attach duct connector.

New Construction
Install duct connector (use screw from parts bag and ensure tabs engage in housing), then attach new construction ductwork with foil tape. Broan-NuTone-BEL6-Room-Side-Fan-Light (7)

Retrofit
Pull ductwork into housing and attach to duct connector with foil tape, then install duct connector (use screw from parts bag and ensure tabs engage in housing).

Broan-NuTone-BEL6-Room-Side-Fan-Light (8)Pro Tip: First and last 18″ of the ducting should be rigid or stretched straight for expected performance.

Connect wiring. Broan-NuTone-BEL6-Room-Side-Fan-Light (9)

Attach wire enclosure by tab and screw.

 

Broan-NuTone-BEL6-Room-Side-Fan-Light (10)

Re-install wiring panel and secure with screw from parts bag. Broan-NuTone-BEL6-Room-Side-Fan-Light (11)

Install the blower assembly with provided screws. Plug in blower.

Note: For new construction, use mask to protect blower until ceiling is finished.

 

Broan-NuTone-BEL6-Room-Side-Fan-Light (12)Install the grille trim with screws from parts bag. Broan-NuTone-BEL6-Room-Side-Fan-Light (13)

Plug in LED moduleBroan-NuTone-BEL6-Room-Side-Fan-Light (14)

Install the grille by sliding clips into grille trim

Broan-NuTone-BEL6-Room-Side-Fan-Light (1)

Documents / Resources

Broan-NuTone BEL6 Room Side Fan Light [pdf] Instruction Manual
BEL6, BENL5, BEL8, BENL8, BEL6 Room Side Fan Light, BEL6, Room Side Fan Light, Fan Light, Light

References

Leave a comment

Your email address will not be published. Required fields are marked *