In signal processing, specifically control theory, bounded-input, bounded-output (BIBO) stability is a form of stability for signals and systems that take inputs. If a system is BIBO stable, then the output will be bounded for every input to the system that is bounded.

A signal is bounded if there is a finite value such that the signal magnitude never exceeds , that is

For discrete-time signals:
For continuous-time signals:

Time-domain condition for linear time-invariant systems

edit

Continuous-time necessary and sufficient condition

edit

For a continuous time linear time-invariant (LTI) system, the condition for BIBO stability is that the impulse response,   , be absolutely integrable, i.e., its L1 norm exists.

 

Discrete-time sufficient condition

edit

For a discrete time LTI system, the condition for BIBO stability is that the impulse response be absolutely summable, i.e., its   norm exists.

 

Proof of sufficiency

edit

Given a discrete time LTI system with impulse response   the relationship between the input   and the output   is

 

where   denotes convolution. Then it follows by the definition of convolution

 

Let   be the maximum value of  , i.e., the  -norm.

 
  (by the triangle inequality)
 

If   is absolutely summable, then   and

 

So if   is absolutely summable and   is bounded, then   is bounded as well because  .

The proof for continuous-time follows the same arguments.

Frequency-domain condition for linear time-invariant systems

edit

Continuous-time signals

edit

For a rational and continuous-time system, the condition for stability is that the region of convergence (ROC) of the Laplace transform includes the imaginary axis. When the system is causal, the ROC is the open region to the right of a vertical line whose abscissa is the real part of the "largest pole", or the pole that has the greatest real part of any pole in the system. The real part of the largest pole defining the ROC is called the abscissa of convergence. Therefore, all poles of the system must be in the strict left half of the s-plane for BIBO stability.

This stability condition can be derived from the above time-domain condition as follows:

 

where   and  

The region of convergence must therefore include the imaginary axis.

Discrete-time signals

edit

For a rational and discrete time system, the condition for stability is that the region of convergence (ROC) of the z-transform includes the unit circle. When the system is causal, the ROC is the open region outside a circle whose radius is the magnitude of the pole with largest magnitude. Therefore, all poles of the system must be inside the unit circle in the z-plane for BIBO stability.

This stability condition can be derived in a similar fashion to the continuous-time derivation:

 

where   and  .

The region of convergence must therefore include the unit circle.

See also

edit

Further reading

edit
  • Gordon E. Carlson Signal and Linear Systems Analysis with Matlab second edition, Wiley, 1998, ISBN 0-471-12465-6
  • John G. Proakis and Dimitris G. Manolakis Digital Signal Processing Principals, Algorithms and Applications third edition, Prentice Hall, 1996, ISBN 0-13-373762-4
  • D. Ronald Fannin, William H. Tranter, and Rodger E. Ziemer Signals & Systems Continuous and Discrete fourth edition, Prentice Hall, 1998, ISBN 0-13-496456-X
  • Proof of the necessary conditions for BIBO stability.
  • Christophe Basso Designing Control Loops for Linear and Switching Power Supplies: A Tutorial Guide first edition, Artech House, 2012, 978-1608075577
  • Michael Unser (2020). "A Note on BIBO Stability". IEEE Transactions on Signal Processing. 68: 5904–5913. arXiv:2005.14428. Bibcode:2020ITSP...68.5904U. doi:10.1109/TSP.2020.3025029.

References

edit