Nothing Special   »   [go: up one dir, main page]

skip to main content
10.1145/3379174.3392317acmconferencesArticle/Chapter ViewAbstractPublication PagesicdarConference Proceedingsconference-collections
research-article

Microwave Doppler Radar Sensing System for Vital Sign Detection: From Evaluated Accuracy Models to the Intelligent System

Published: 08 June 2020 Publication History

Abstract

The development of microwave radar vital sign sensing system brings many benefits to mankind. This system can be used to detect the location of living people buried under debris. Other important applications of microwave radar sensor are smart home, health care and defense. There are several main blocks in the radar sensor such as a transmitter, a receiver, a signal processing circuit and a display block. The transmitter propagates radio frequency signals toward the human and collects the reflected signals from the human chest. By analyzing transmitted and received signals, useful information like breathing rate, heartbeat, and people's location are taken. This work focuses on the studying mathematical model to evaluate the accuracy of radar vital sign sensing system when the operating frequency and distance change. Moreover, the integration between AI technique and radar sensor is also considered carefully in this study. The combination makes this system smarter, enables more applications and brings more benefits to users.

References

[1]
CG Caro and JA Bloice. 1971. Contactless apnoea detector based on radar. The Lancet 298, 7731 (1971), 959--961.
[2]
Kun-Mu Chen, Yong Huang, Jianping Zhang, and Adam Norman. 2000. Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. IEEE transactions on biomedical engineering 47, 1 (2000), 105--114.
[3]
Minh-Son Dao, Tuan-Anh Nguyen-Gia, and Van-Cuong Mai. 2017. Daily human activities recognition using heterogeneous sensors from smartphones. Procedia computer science 111 (2017), 323--328.
[4]
Massimo Donelli. 2011. A rescue radar system for the detection of victims trapped under rubble based on the independent component analysis algorithm. Progress In Electromagnetics Research 19 (2011), 173--181.
[5]
Amy D Droitcour, Olga Boric-Lubecke, and Gregory TA Kovacs. 2009. Signal-tonoise ratio in Doppler radar system for heart and respiratory rate measurements. IEEE transactions on microwave theory and techniques 57, 10 (2009), 2498--2507.
[6]
Sefa Erdogan, Sener Yilmaz, and Ahmet Öncü. 2019. Microwave Noncontact Vital Sign Measurements for Medical Applications. In 2019 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, 1--5.
[7]
Changzhan Gu, Guochao Wang, Takao Inoue, and Changzhi Li. 2013. Doppler radar vital sign detection with random body movement cancellation based on adaptive phase compensation. In 2013 IEEE MTT-S International Microwave Symposium Digest (MTT). IEEE, 1--3.
[8]
Laleh Jalali, Minh-Son Dao, Ramesh Jain, and Koiji Zettsu. 2015. Complex asthma risk factor recognition from heterogeneous data streams. In 2015 IEEE International Conference on Multimedia & Expo Workshops (ICMEW). IEEE, 1--6.
[9]
Byung-Jun Jang, Sang-Hyuk Wi, Jong-Gwan Yook, Moon-Que Lee, and Kyoung- Joung Lee. 2008. Wireless bio-radar sensor for heartbeat and respiration detection. Progress In Electromagnetics Research 5 (2008), 149--168.
[10]
Hsin-Chih Kuo, Chien-Chih Lin, Chun-Han Yu, Pei-Hua Lo, Jhin-Ying Lyu, Chien- Chang Chou, and Huey-Ru Chuang. 2016. A fully integrated 60-GHz CMOS direct-conversion Doppler radar RF sensor with clutter canceller for single antenna noncontact human vital-signs detection. IEEE transactions on Microwave Theory and Techniques 64, 4 (2016), 1018--1028.
[11]
Antonio Lazaro, David Girbau, and Ramon Villarino. 2014. Techniques for clutter suppression in the presence of body movements during the detection of respiratory activity through UWB radars. Sensors 14, 2 (2014), 2595--2618.
[12]
Xiaolin Liang, Jianqin Deng, Hao Zhang, and Thomas Aaron Gulliver. 2018. Ultrawide band impulse radar through-wall detection of vital signs. Scientific reports 8, 1 (2018), 1--21.
[13]
Stefano Pisa, Erika Pittella, and Emanuele Piuzzi. 2016. A survey of radar systems for medical applications. IEEE Aerospace and Electronic Systems Magazine 31, 11 (2016), 64--81.
[14]
Tomohiro Sato, Minh-Son Dao, Kota Kuribayashi, and Koji Zettsu. 2019. SEPHLA: challenges and opportunities within environment-personal health archives. In International Conference on Multimedia Modeling. Springer, 325--337.
[15]
Enrico M Staderini. 2002. UWB radars in medicine. IEEE aerospace and electronic systems magazine 17, 1 (2002), 13--18.
[16]
Nguyen Thi Phuoc Van, Liqiong Tang, Veysel Demir, Syed Faraz Hasan, Nguyen Duc Minh, and Subhas Mukhopadhyay. 2019. Microwave Radar Sensing Systems for Search and Rescue Purposes. Sensors 19, 13 (2019), 2879.
[17]
Nguyen Thi Phuoc Van, Liqiong Tang, Nguyen Duc Minh, Faraz Hasan, and Subhas Mukhopadhyay. 2017. Extra wide band 3D patch antennae system design for remote vital sign Doppler radar sensor detection. In 2017 Eleventh International Conference on Sensing Technology (ICST). IEEE, 1--5.
[18]
Nguyen Thi Phuoc Van, Liqiong Tang, Amardeep Singh, Nguyen Duc Minh, Subhas Chandra Mukhopadhyay, and Syed Faraz Hasan. 2019. Self-identification respiratory disorder based on continuous wave radar sensor system. IEEE Access 7 (2019), 40019--40026.
[19]
Phuoc Van, Nguyen Thi, Liqiong Tang, Subhas Chandra Mukhopadhyay, Duc Minh Nguyen, and Faraz Hasan. 2018. Probabilities of false alarm for vital sign detection on the basis of a Doppler radar system. Sensors 18, 3 (2018), 694.
[20]
Thi Phuoc Van Nguyen, Liqiong Tang, Faraz Hasan, Nguyen Duc Minh, and Subhas Mukhopadhyay. 2018. Nature-inspired sensor system for vital signs detection. Sensors and Actuators A: Physical 281 (2018), 76--83.
[21]
M Varanini, PC Berardi, F Conforti, M Micalizzi, D Neglia, and ALBERTO Macerata. 2008. Cardiac and respiratory monitoring through non-invasive and contactless radar technique. In 2008 Computers in Cardiology. IEEE, 149--152.
[22]
Zhao Wang, Eng Gee Lim, Yujun Tang, and Mark Leach. 2014. Medical applications of microwave imaging. The Scientific World Journal 2014 (2014).
[23]
Yang Zhang, Teng Jiao, Hao Lv, Sheng Li, Changzhi Li, Guohua Lu, Xiao Yu, Zhao Li, and Jianqi Wang. 2014. An interference suppression technique for life detection using 5.75-and 35-GHz dual-frequency continuous-wave radar. IEEE Geoscience and Remote Sensing Letters 12, 3 (2014), 482--486.

Cited By

View all
  • (2023)Identification of Humans in a Disaster using Radio Frequency Technique2023 Global Conference on Wireless and Optical Technologies (GCWOT)10.1109/GCWOT57803.2023.10064672(1-4)Online publication date: 24-Jan-2023
  • (2021)Multiple Time-Variant Targets Detection using MIMO Radar Framework for Cerebrovascular Monitoring2021 15th European Conference on Antennas and Propagation (EuCAP)10.23919/EuCAP51087.2021.9411329(1-5)Online publication date: 22-Mar-2021

Index Terms

  1. Microwave Doppler Radar Sensing System for Vital Sign Detection: From Evaluated Accuracy Models to the Intelligent System

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Conferences
    ICDAR '20: Proceedings of the 2020 ACM Workshop on Intelligent Cross-Data Analysis and Retrieval
    June 2020
    44 pages
    ISBN:9781450375092
    DOI:10.1145/3379174
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    Sponsors

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 08 June 2020

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. knn
    2. machine learning
    3. radar sensor
    4. smart sensing system
    5. svm

    Qualifiers

    • Research-article

    Conference

    ICMR '20
    Sponsor:

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • Downloads (Last 12 months)11
    • Downloads (Last 6 weeks)0
    Reflects downloads up to 28 Sep 2024

    Other Metrics

    Citations

    Cited By

    View all
    • (2023)Identification of Humans in a Disaster using Radio Frequency Technique2023 Global Conference on Wireless and Optical Technologies (GCWOT)10.1109/GCWOT57803.2023.10064672(1-4)Online publication date: 24-Jan-2023
    • (2021)Multiple Time-Variant Targets Detection using MIMO Radar Framework for Cerebrovascular Monitoring2021 15th European Conference on Antennas and Propagation (EuCAP)10.23919/EuCAP51087.2021.9411329(1-5)Online publication date: 22-Mar-2021

    View Options

    Get Access

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Media

    Figures

    Other

    Tables

    Share

    Share

    Share this Publication link

    Share on social media