Analysis of Negative Current Caused by Three-phase Four-Wire Electric Energy Meter under Normal Wiring

Published: 10 April 2023 Publication History

Abstract

Three-phase four-wire is one of the widely used wiring methods for electric energy meters. The electric energy meter of non-power customers should have a positive current under normal wiring conditions, but in the actual field, it is found that the current is case of negative values. This paper statistically analyzes the load situation and time law of normal wiring users when the outgoing line negative current, and analyzes the phase relationship between voltage and current by vector diagram. It has been confirmed in the on-site actual inspection, which provides an important reference for the remote accurate judgment of measurement error wiring.

References

[1]
Yuerong Wang, Xiaoqun Zhao. An auxiliary wiring tool for high-voltage metering devices [J]. Rural Electrician 2021, 29(12): 27-28.
[2]
Bo Liang, Fengxiang Wang, Wei Xu. Analysis of the installation and connection of the meter (Continued 1) [J]. Rural Electrician, 2021, 29(02): 56-57.
[3]
Luo Luo. Discussion on the calculation method of missing electricity in electric energy metering management system [J]. Science and Technology Innovation, 2021(01):191-192.
[4]
Mingzhu Li, Weiting Sun, Mengyao Zhang. Measurement analysis of several misconnections of three-phase four-wire active energy meters [J]. Electrical Technology, 2020(22):126-128.
[5]
Daiguo Yuan. Analysis of device with three-phase four-wire electric energy metering [J]. Electromechanical Information, 2020(33):54-55.
[6]
Jiangteng Li, Fei Wang. Detection of abnormal power consumption of industrial and commercial users based on knowledge embedding and DNN [J]. Electric Power Engineering Technology, 2020, 39(03):158-165.
[7]
Hongwei Jia, Yixuan Yang, Qiyin Han. Three-phase four-wire electric energy measurement error wiring training software design [J]. Journal of Guangdong Water Conservancy and Electric Power Vocational and Technical College, 2020, 18(01): 40-43.
[8]
Xiaoqun Zhao, Lei Cao, Wu Zhang. Application of modularization + big data processing technology to improve the wiring rate of new metering [J]. Electronic Measurement Technology, 2020,43(05):150-155.
[9]
Zhenna Li, Kun Cai, Rulan Lin. Analysis of the influence of wrong wiring of three-phase four-wire electric energy meter on electric energy measurement [J]. Measurement and Testing Technology, 2019,46(08):69-72.
[10]
Guosheng Li, Jianwu Tao, Xue Zheng, Ying Wang, Nianqun Yu, Jun Wang. The influence of the three-phase four-wire electric energy metering device on the electric energy measurement after the neutral line of the meter is disconnected [J]. Instrument Standardization and Measurement, 2019 (04):39-41.
[11]
Jing Fan. Judgment of wrong wiring of three-phase four-wire electric energy metering device based on hexagonal diagram method [J]. Electromechanical Information, 2019(03):1-2.

Recommendations

Comments

Please enable JavaScript to view thecomments powered by Disqus.

Information & Contributors

Information

Published In

cover image ACM Other conferences
ICITEE '22: Proceedings of the 5th International Conference on Information Technologies and Electrical Engineering
November 2022
739 pages
ISBN:9781450396806
DOI:10.1145/3582935
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than the author(s) must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected].

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 10 April 2023

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. Electric energy metering
  2. Meter
  3. Negative current
  4. Three-phase four-wire
  5. Wrong wiring

Qualifiers

  • Research-article
  • Research
  • Refereed limited

Conference

ICITEE 2022

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 15
    Total Downloads
  • Downloads (Last 12 months)3
  • Downloads (Last 6 weeks)0
Reflects downloads up to 22 Nov 2024

Other Metrics

Citations

View Options

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

HTML Format

View this article in HTML Format.

HTML Format

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media