Nothing Special   »   [go: up one dir, main page]

skip to main content
10.1145/3326172.3326197acmotherconferencesArticle/Chapter ViewAbstractPublication PagesicbetConference Proceedingsconference-collections
research-article

Assessment of Line-of-Response Probability Density Function System Matrix for PET

Published: 28 March 2019 Publication History

Abstract

System matrix is an essential element to build the iterative PET image reconstruction algorithm. In this paper, the analytical calculation method and Monte Carlo method are respectively used to generate the system matrices. The obtained system matrices are verified in GATE with the simulation model according to the actual PET. The reconstructed images obtained by these two methods are compared according to image quality evaluation parameters of PSNR and SSIM. Simulation results show that the quality of the reconstructed image by Monte Carlo method is much better. But it takes much long time to build the Monte Carlo system matrix, and the reconstructed image by Monte Carlo method degenerates greatly with the iteration time increasing.

References

[1]
Lecomte R, Schmitt D and Lamoureux G, 1984. Geometry study of a high-resolution PET detection system using small detectors. IEEE Transactions on Nuclear Science. 31: 556--61.
[2]
Selivanov V, Picard Y, Cadorette J, Rodrigue S and Lecomte R. 2000. Detector response models for statistical iterative image reconstruction in high resolution PET. IEEE Transactions on Nuclear Science. 47: 1168--75.
[3]
Strul D, Slates R B, Dahlbom M, Cherry S R and Marsden P K. 2003. An improved analytical detector response function model for multilayer small-diameter PET scanners. Physics in Medicine and Biology. 48: 979--94.
[4]
SIDDON R L. Fast calculation of the exact radiological path for a three dimensional CT array. Medical Physics. 1985.
[5]
Rafecas M et al. 2004. Use of a Monte Carlo-based probability matrix for 3-D iterative reconstruction of MADPET-II data. IEEE Transactions on Nuclear Science 51:2597--605.
[6]
Rutao Yao et al. 2012. Assessment of a three-dimensional line-of response probability density function system matrix for PET. Physics in Medicine and Biology. 57: 682.
[7]
Rafecas M, Boning G, Pichler B J, Lorenz E, Schwaiger M and Ziegler S I. 2004. Effect of noise in the probability matrix used for statistical reconstruction of PET data. IEEE Transactions on Nuclear Science. 51: 149--56.
[8]
Qi J Y, Leahy R M, Cherry S R, Chatziioannou A and Farquhar T H. 1998. High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. Physics in Medicine and Biology. 43: 1001--13.
[9]
Buvat I and Castiglioni I. 2002. Monte Carlo simulations in SPET and PET. Q. J. Nucl. Med. 46: 48--61.
[10]
Jan S et al. 2004. GATE: a simulation toolkit for PET and SPECT. Physics in Medicine and Biology. 49: 4543--61.
[11]
Conias P, Bertsekas N, Karakatsanis N et al. 2007.Validation of a GATE model for the simulation of the Siemens biographTM 6 PET scanner. Nuclear Instruments and Methods in Physics Research. 57(1-2): 263--266.

Index Terms

  1. Assessment of Line-of-Response Probability Density Function System Matrix for PET

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    ICBET '19: Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology
    March 2019
    327 pages
    ISBN:9781450361309
    DOI:10.1145/3326172
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 28 March 2019

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. Iterative algorithms
    2. PET
    3. Reconstruction image
    4. Sinogram
    5. System matrix

    Qualifiers

    • Research-article
    • Research
    • Refereed limited

    Conference

    ICBET ' 19

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • 0
      Total Citations
    • 37
      Total Downloads
    • Downloads (Last 12 months)2
    • Downloads (Last 6 weeks)0
    Reflects downloads up to 18 Nov 2024

    Other Metrics

    Citations

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Media

    Figures

    Other

    Tables

    Share

    Share

    Share this Publication link

    Share on social media