Design and Realization of Portable Water Quality PH Detector

Published: 29 December 2018 Publication History

Abstract

At present, many PH value measuring instruments on the market have many problems, for example, the measurement accuracy is not high enough, the circuit wiring is too complicated, and the stability is not strong. Therefore, in order to improve the measurement accuracy of the detector, reduce the effect of temperature on the pH measurement of the solution, simplify the circuit layout, and enhance the stability of the measurement circuit, Developed a STC89C52 microcontroller as the core processor, using Raycore E-201-CPH composite electrode to collect analog voltage signal and transfer it to A/D converter to convert into digital signal after amplified by op amp, and input it into the single-chip microcomputer together with the digital signal collected by the temperature sensor. Finally, after processing by the SCM, it is transmitted to the LCD1602 liquid crystal display module, showing the measured pH value and temperature value. The whole design is made down, and after many debugging, it can be concluded that the PH detector can accurately detect the PH value of the solution. It also has the characteristics of cheaper, affordable, high precision, good stability, simple circuit, simple operation and so on, which is suitable for the needs of most of the current users.

References

[1]
Caldeira K, Wickett M. Oceanography: anthropogenic carbon and ocean pH.{J}. Nature, 2003, 425(6956):365.
[2]
Soetaert K, Hofmann A to F, Middelburg J J, et al. The effect of biogeochemical The processes on pH {J}. Journal of Marine Chemistry, 2007, 105 (1): 30--51.
[3]
Alice. real-time implementation of multi-linear model-based control strategies-an application to A bench pH neutralization reactor{J}, Journal of process control 14, 2004:571--579.
[4]
Sung S.W. Lee i. pH Control Using a Simple Set point Change{J}. Ind. Eng.Chem. Res. 1995, 34:1730.
[5]
Clayton J W, n. Tretiak D Amine - Citrate Buffers for pH Control in Starch Gel Electrophoresis {J}. Journal of Fisheries Research Board of Canada, 2011, 29 (8): 1169--1172.
[6]
Wright R.A. Kravaris c. Nonlinear control of pH processes using the strong acid equivalent{J}. Ind. Eng.Chem. Res. 1991, 30:1561--1572.
[7]
Qi jianguang, li baoying, li renqing. Design of ultra-low power consumption water pH meter {J}. Instrument technology and sensor, 2017(3):118--120.
[8]
liu hai, Yang huizhong. An intelligent online pH detector {J}. Journal of jiangnan university (natural science edition), 2012, 11(2):173--177

Cited By

View all
  • (2023)Alerting of Acid Rain Using Rain Sensor, pH Sensor and SO2 Sensor on Street Lights2023 4th International Conference on Electronics and Sustainable Communication Systems (ICESC)10.1109/ICESC57686.2023.10193391(497-502)Online publication date: 6-Jul-2023

Index Terms

  1. Design and Realization of Portable Water Quality PH Detector

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    ISBDAI '18: Proceedings of the International Symposium on Big Data and Artificial Intelligence
    December 2018
    365 pages
    ISBN:9781450365703
    DOI:10.1145/3305275
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    In-Cooperation

    • International Engineering and Technology Institute, Hong Kong: International Engineering and Technology Institute, Hong Kong

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 29 December 2018

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. Data Acquisition
    2. Monitoring
    3. PH Detection
    4. Temperature

    Qualifiers

    • Short-paper
    • Research
    • Refereed limited

    Conference

    ISBDAI '18

    Acceptance Rates

    ISBDAI '18 Paper Acceptance Rate 70 of 340 submissions, 21%;
    Overall Acceptance Rate 70 of 340 submissions, 21%

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • Downloads (Last 12 months)6
    • Downloads (Last 6 weeks)0
    Reflects downloads up to 10 Nov 2024

    Other Metrics

    Citations

    Cited By

    View all
    • (2023)Alerting of Acid Rain Using Rain Sensor, pH Sensor and SO2 Sensor on Street Lights2023 4th International Conference on Electronics and Sustainable Communication Systems (ICESC)10.1109/ICESC57686.2023.10193391(497-502)Online publication date: 6-Jul-2023

    View Options

    Get Access

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Media

    Figures

    Other

    Tables

    Share

    Share

    Share this Publication link

    Share on social media