Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 找到 2,046 筆記錄  1 - 10下一個最後  跳到記錄: 檢索需時 0.77 秒. 
1.
The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control and Safety Systems during the Second Long Shutdown of the Large Hadron Collider at CERN / CMS Collaboration
The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detectors integrity since the CMS commissioning phase, more than 10 years ago. [...]
CMS-CR-2020-011.- Geneva : CERN, 2020 - 9 p. - Published in : EPJ Web Conf. 245 (2020) 01009 Fulltext: PDF;
In : 24th International Conference on Computing in High Energy and Nuclear Physics, Adelaide, Australia, 4 - 8 Nov 2019, pp.01009
2.
CMS ECAL Detector Control System Upgrade Plan for the CERN Large Hadron Collider Long Shutdown II / Jimenez Estupinan, Raul (Zurich, ETH) /CMS Collaboration
The Electromagnetic Calorimeter (ECAL) is one of the detectors of the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC). The ECAL Detector Control System (DCS) software has been implemented using the WinCC Open Architecture (OA) platform. [...]
CMS-CR-2018-230.- Geneva : CERN, 2018 - 5 p. - Published in : 10.18429/JACoW-PCaPAC2018-WEP16 Fulltext: PDF;
In : 12th International Workshop on Personal Computers and Particle Accelerator Controls (PCaPAC), Hsinchu, Taiwan, 16 - 19 Oct 2018, pp.WEP16
3.
Software migration of the CMS ECAL Detector Control System during the CERN Large Hadron Collider Long Shutdown II / CMS Collaboration
During the second long shutdown (LS2) of the CERN Large Hadron Collider (LHC), the Detector Control System (DCS) of the CMS Electromagnetic Calorimeter (ECAL) is undergoing a large software upgrade at various levels. The supervisory software has been reviewed, extended and migrated to use the latest versions of the underlying software technologies. [...]
CMS-CR-2021-102.- Geneva : CERN, 2021 - 9 p. - Published in : EPJ Web Conf. 251 (2021) 04007 Fulltext: PDF;
In : 25th International Conference on Computing in High-Energy and Nuclear Physics (CHEP), Online, Online, 17 - 21 May 2021, pp.04007
4.
Phase-II Upgrade of the CMS Electromagnetic Calorimeter Detector Control and Safety Systems for the High Luminosity Large Hadron Collider / Jimenez Estupinan, Raul (Zurich, ETH) /CMS Collaboration
The Electromagnetic Calorimeter (ECAL) is a subdetector of the CMS experiment. Composed of a barrel and two endcaps, ECAL uses lead tungstate scintillating crystals to measure the energy of electrons and photons produced in high-energy collisions at the Large Hadron Collider (LHC). [...]
CMS-CR-2023-175.- Geneva : CERN, 2023 - 7 p. - Published in : JACoW ICALEPS2023 (2023) 1516-1521 Fulltext: PDF;
In : 19th International Conference on Accelerator and Large Experimental Physics Control Systems (ICALEPCS 2023), Cape Town, South Africa, 7 - 13 Oct 2023, pp.1516-1521
5.
Improving the safety and protective automatic actions of the CMS electromagnetic calorimeter detector control system / Jimenez Estupinan, Raul (Zurich, ETH) ; Adzic, Peter (Belgrade U.) ; Cirkovic, Predrag (Belgrade U.) ; Di Calafiori, Diogo Raphael (ETH, Zurich (main)) ; Dissertori, Guenther (ETH, Zurich (main)) ; Djambazov, Lubomir (ETH, Zurich (main)) ; Jovanovic, Dragoslav (Belgrade U.) ; Lustermann, Werner (ETH, Zurich (main)) ; Milenovic, Predrag (Belgrade U.) ; Zelepoukine, Serguei (ETH, Zurich (main) ; Wisconsin U., Madison) /CMS Collaboration
The CMS ECAL Detector Control System (DCS) features several monitoring mechanisms able to react and perform automatic actions based on pre-defined action matrices. The DCS is capable of early detection of anomalies inside the ECAL and on its off-detector support systems, triggering automatic actions to mitigate the impact of these events and preventing them from escalating to the safety system. [...]
CMS-CR-2017-310.- Geneva : CERN, 2018 - 4 p. - Published in : 10.18429/JACoW-ICALEPCS2017-THPHA109 Fulltext: PDF; External link: Fulltext
In : 16th International Conference on Accelerator and Large Experimental Physics Control Systems, Barcelona, Spain, 8 - 13 Oct 2017, pp.THPHA109
6.
Extending the remote control capabilities in the CMS Detector Control System with Remote Procedure Call Services / Jimenez Estupinan, Raul (Zurich, ETH) /CMS Collaboration
The CMS Detector Control System (DCS) is implemented as a large distributed and redundant system, with applications interacting and sharing data in multiple ways. The CMS XML-RPC is a software toolkit implementing the standard Remote Procedure Call (RPC) protocol, using the Extensible Mark-up Language (XML) and a custom lightweight variant using the JavaScript Object Notation (JSON) to model, encode and expose resources through the Hypertext Transfer Protocol (HTTP). [...]
CMS-CR-2018-218.- Geneva : CERN, 2018 - 5 p. - Published in : 10.18429/JACoW-PCaPAC2018-WEP17 Fulltext: CR2018_218 - PDF; Publication - PDF;
In : 12th International Workshop on Personal Computers and Particle Accelerator Controls (PCaPAC), Hsinchu, Taiwan, 16 - 19 Oct 2018, pp.WEP17
7.
The CMS Data Acquisition - Architectures for the Phase-2 Upgrade / Andre, Jean-Marc Olivier (Fermilab) ; Behrens, Ulf (DESY) ; Branson, James (UC, San Diego) ; Brummer, Philipp Maximilian (CERN) ; Chaze, Olivier (CERN) ; Cittolin, Sergio (UC, San Diego) ; Contescu, Cristian (Fermilab) ; Craigs, Benjamin Gordon (CERN) ; Darlea, Georgiana Lavinia (MIT) ; Deldicque, Christian (CERN) et al.
The upgraded High Luminosity LHC, after the third Long Shutdown (LS3), will provide an instantaneous luminosity of $7.5\times10^{34}$ cm$^{-2} s^{-1}$ (levelled), at the price of extreme pileup of up to 200 interactions per crossing. In LS3, the CMS Detector will also undergo a major upgrade to prepare for the phase-2 of the LHC physics program, starting around 2025. [...]
CMS-CR-2017-030.- Geneva : CERN, 2017 - 8 p. - Published in : J. Phys.: Conf. Ser. 898 (2017) 032019 Fulltext: PDF; External link: IOP Open Access Article
In : 22nd International Conference on Computing in High Energy and Nuclear Physics, CHEP 2016, San Francisco, Usa, 10 - 14 Oct 2016, pp.032019
8.
Performance of the CMS Event Builder / Andre, Jean-Marc Olivier (Fermilab) ; Behrens, Ulf (DESY) ; Branson, James (UC, San Diego) ; Brummer, Philipp Maximilian (CERN) ; Chaze, Olivier (CERN) ; Cittolin, Sergio (UC, San Diego) ; Contescu, Cristian (Fermilab) ; Craigs, Benjamin Gordon (CERN) ; Darlea, Georgiana Lavinia (MIT) ; Deldicque, Christian (CERN) et al.
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of to the high-level trigger farm. The DAQ architecture is based on state-of-the-art network technologies for the event building. [...]
CMS-CR-2017-034.- Geneva : CERN, 2017 - 8 p. - Published in : J. Phys.: Conf. Ser. 898 (2017) 032020 Fulltext: PDF; External link: IOP Open Access Article
In : 22nd International Conference on Computing in High Energy and Nuclear Physics, CHEP 2016, San Francisco, Usa, 10 - 14 Oct 2016, pp.032020
9.
The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System / Holme, Oliver (Zurich, ETH) ; Adzic, P (Belgrade U. ; VINCA Inst. Nucl. Sci., Belgrade) ; Calafiori, D Di (Zurich, ETH) ; Dissertori, G (Zurich, ETH) ; Djambazov, L (Zurich, ETH) ; Jovanovic, D (Belgrade U. ; VINCA Inst. Nucl. Sci., Belgrade) ; Lustermann, W (Zurich, ETH) ; Zelepoukine, S (Zurich, ETH)
The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that had been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. [...]
CMS-CR-2013-323.- Geneva : CERN, 2013 - 6 p. Fulltext: PDF;
In : 20th International Conference on Computing in High Energy and Nuclear Physics 2013, Amsterdam, Netherlands, 14 - 18 Oct 2013
10.
The CMS ECAL Control and Safety Systems Upgrades During the CERN LHC Long Shutdown 2 / Di Calafiori, Diogo Raphael (ETH, Zurich (main)) ; Dissertori, Guenther (ETH, Zurich (main)) ; Jiménez Estupinan, Raúl (ETH, Zurich (main)) ; Lustermann, Werner (ETH, Zurich (main)) ; Tsirou, Andromachi (CERN) ; Verdini, Piero Giorgio (INFN, Pisa ; Pisa, Scuola Normale Superiore) ; Zelepoukine, Serguei (Wisconsin U., Madison ; ETH, Zurich (main))
The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. [...]
2020 - 5 p. - Published in : 10.18429/JACoW-ICALEPCS2019-WEPHA041 Fulltext: PDF;
In : 17th Biennial International Conference on Accelerator and Large Experimental Physics Control Systems (ICALEPCS), New York, United States, 5 - 11 Oct 2019, pp.WEPHA041

沒有尋找到什麼? 嘗試在以下的服務器查尋:
recid:2798126 在 Amazon
recid:2798126 在 CERN EDMS
recid:2798126 在 CERN Intranet
recid:2798126 在 CiteSeer
recid:2798126 在 Google Books
recid:2798126 在 Google Scholar
recid:2798126 在 Google Web
recid:2798126 在 IEC
recid:2798126 在 IHS
recid:2798126 在 INSPIRE
recid:2798126 在 ISO
recid:2798126 在 KISS Books/Journals
recid:2798126 在 KISS Preprints
recid:2798126 在 NEBIS
recid:2798126 在 SLAC Library Catalog