1.
A Family of Gas Ionization Chambers and SEM for Beam Loss Monitoring of LHC and Other Accelerators / Grishin, Viatcheslav (ESS, Lund) ; Dehning, Bernd (CERN) ; Effinger, Ewald (CERN) ; Emery, Jonathan (CERN) ; Holzer, Eva Barbara (CERN) ; Koshelev, Andrey (Serpukhov, IHEP) ; Larionov, Anatoly (Serpukhov, IHEP) ; Medvedeva, Tatiana (CERN) ; Seleznev, Vladimir (Serpukhov, IHEP) ; Sleptsov, Mikhail (Serpukhov, IHEP) et al.
A serious problem for high current accelerators is the high density of the beam, which is able to destroy the equipment and to make a quench of super conductive magnets. Loss of even a small fraction of this intense beam equipment. [...]
2018 - 5 p. - Published in : 10.18429/JACoW-RuPAC2018-TUZMH03 Fulltext: PDF;
In : 26th Russian Particle Accelerator Conference, Protvino, Russia, 1 - 5 Oct 2018, pp.TUZMH03
2.
Ionization Chambers as Beam Loss Monitors for ESS Linear Accelerator / Grishin, Viatcheslav (ESS, Lund) ; Dehning, Bernd (CERN) ; Koshelev, Andrey (Serpukhov, IHEP) ; Larionov, Anatoli (Serpukhov, IHEP) ; Seleznev, Vladimir (Serpukhov, IHEP) ; Sleptsov, Mikhail (Serpukhov, IHEP)
The European Spallation Source (ESS) to be under construction in Lund, Sweden, will provide a highest average intensity beam from a 5 MW superconducting proton linear accelerator to produce spallation neutrons. A serious problem for high current accelerators is the high density of the beam, which is able to destroy the equipment, to make a quench of super conductive magnets [...]
2018 - 4 p. - Published in : 10.18429/JACoW-IBIC2017-WEPWC03 Fulltext: PDF;
In : 6th International Beam Instrumentation Conference, Grand Rapids, MI, USA, 20 -24 Aug 2017, pp.WEPWC03
3.
Detector Response Studies of the ESS Ionization Chamber / Dolenc Kittelmann, Irena (ESS, Lund) ; Boutachkov, Plamen (Darmstadt, GSI) ; Effinger, Ewald (CERN) ; Grishin, Viatcheslav ; Lernevall, Anders ; Viganò, William ; Zamantzas, Christos
The European Spallation Source (ESS), currently under construction in Lund, Sweden, will be a pulsed neutron source based on a proton linac. The ESS linac is designed to deliver a 2GeV beam with peak current of 62.5mA at 14 Hz to a rotating tungsten target for neutron production. [...]
2023 - 4 p. - Published in : JACoW IBIC 2023 (2023) TUP004 Fulltext: PDF;
In : 12th International Beam Instrumentation Conference (IBIC 2023), Saskatoon, Canada, 10 - 14 Sep 2023, pp.TUP004
4.
Development, Production and Testing of 4500 Beam Loss Monitors / Holzer, E B (CERN) ; Chiggiato, P (CERN) ; Dehning, B (CERN) ; Ferioli, G (CERN) ; Grishin, V (Serpukhov, IHEP) ; Jimenez, T M (CERN) ; Koshelev, A (Serpukhov, IHEP) ; Kramer, Daniel (CERN) ; Larionov, A (Serpukhov, IHEP) ; Taborelli, M (CERN) et al.
Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. [...]
CERN-AB-2008-054.- Geneva : CERN, 2008 - 4 p. Fulltext: PDF; External link: Published version from JACoW
In : 11th European Particle Accelerator Conference, Genoa, Italy, 23 - 27 Jun 2008, pp.TUPC037
5.
Beam Loss Monitoring for Run 2 of the LHC / Kalliokoski, Matti (CERN) ; Auchmann, Bernhard (CERN) ; Dehning, Bernd (CERN) ; Domingues Sousa, Fernando (CERN) ; Effinger, Ewald (CERN) ; Emery, Jonathan (CERN) ; Grishin, Viatcheslav (CERN) ; Holzer, Eva Barbara (CERN) ; Jackson, Stephen (CERN) ; Kolad, Blazej (CERN) et al.
The Beam Loss Monitoring (BLM) system of the LHC consists of over 3600 ionization chambers. The main task of the system is to prevent the superconducting magnets from quenching and protect the machine components from damage, as a result of critical beam losses. [...]
CERN-ACC-2015-308.- 2015 - 4 p. - Published in : (2015) , pp. MOPTY055 Published version from JACoW: PDF; External link: JACOW
In : 6th International Particle Accelerator Conference, Richmond, VA, USA, 3 - 8 May 2015, pp.MOPTY055
6.
The Beam Loss Monitoring System after LHC Long Shutdown 2 at CERN / Saccani, Mathieu (CERN) ; Effinger, Ewald (CERN) ; Viganò, William (CERN) ; Zamantzas, Christos (CERN)
Most of the LHC systems at CERN were updated during the Long Shutdown 2, from December 2018 to July 2022, to prepare the accelerator for High-Luminosity. The Beam Loss Monitoring system is a key part of the LHC’s instrumentation for machine protection and beam optimisation by producing continuous and reliable measurements of beam losses along the accelerator. [...]
2022 - 5 p. - Published in : JACoW IBIC 2022 (2022) 220-224 Fulltext: PDF;
In : 11th International Beam Instrumentation Conference (IBIC 2022), Cracow, Poland, 11 - 15 Sep 2022, pp.220-224
7.
Optical Beam Loss Monitor for RF Cavity Characterisation / Alexandrova, Alexandra (Cockcroft Inst. Accel. Sci. Tech.) ; Brynes, Alexander (Daresbury) ; Devlin, Lee (U. Liverpool (main) ; Cockcroft Inst. Accel. Sci. Tech.) ; Effinger, Ewald (CERN) ; Holzer, Eva Barbara (CERN) ; Jackson, Frank (Daresbury ; Cockcroft Inst. Accel. Sci. Tech.) ; Kastriotou, Maria (U. Liverpool (main) ; CERN) ; Scott, Duncan (Daresbury ; Cockcroft Inst. Accel. Sci. Tech.) ; Tzoganis, Vasilis (U. Liverpool (main) ; Cockcroft Inst. Accel. Sci. Tech.) ; Welsch, Carsten (U. Liverpool (main) ; Cockcroft Inst. Accel. Sci. Tech.) et al.
Beam Loss Monitors (BLMs) based on optical fibres have been under development for many years as an alternative solution to commonly used methods, such as ionisation chambers. Optical BLMs (oBLMs) maintain standard BLM functionality but can also be used for machine and personal protection. [...]
2018 - 4 p. - Published in : 10.18429/JACoW-IBIC2017-WEPWC01 Fulltext: PDF;
In : 6th International Beam Instrumentation Conference, Grand Rapids, MI, USA, 20 -24 Aug 2017, pp.WEPWC01
8.
BLM Crosstalk Studies on the CLIC Two-Beam Module / Kastriotou, Maria (CERN ; Liverpool U. ; Cockcroft Inst. Accel. Sci. Tech.) ; Döbert, Steffen (CERN) ; Domingues Sousa, Fernando (CERN) ; Effinger, Ewald (CERN) ; Farabolini, Wilfrid (CERN ; CEA, DSM, Saclay ; IRFU, Saclay) ; Holzer, Eva Barbara (CERN) ; Nebot Del Busto, Eduardo (CERN ; Liverpool U.) ; Viganò, William (CERN) ; Welsch, Carsten (Cockcroft Inst. Accel. Sci. Tech. ; Liverpool U.)
The Compact Linear Collider (CLIC) is a proposal for a future linear e⁺-e⁻ accelerator that can reach 3 TeV centre of mass energy. It is based on a two-beam acceleration scheme, with two accelerators operating in parallel. [...]
2016 - 4 p. - Published in : 10.18429/JACoW-IBIC2015-MOPB045 Fulltext: PDF;
In : International Beam Instrumentation Conference , Melbourne, Australia, 13 - 17 Sep 2015, pp.MOPB045
9.
The Beam Loss Monitoring System after LHC Injectors Upgrade at CERN / Saccani, Mathieu (CERN) ; Calvo Giraldo, Eva (CERN) ; Viganò, William (CERN) ; Zamantzas, Christos (CERN)
The LHC Injector Upgrade project aims to increase the brightness of the beams available and improve the efficiency of the whole accelerator chain. The Beam Loss Monitoring (BLM) system is a key element of CERN’s accelerator instrumentation for beam optimisation and machine protection by producing continuous and reliable beam loss measurements while ensuring safe operation. [...]
JACoW, 2021 - 5 p. - Published in : JACoW IBIC 2021 (2021) 285-289 Fulltext: PDF;
In : 10th International Beam Instrumentation Conference (IBIC 2021), Online, Korea, 13 - 17 Sep 2021, pp.285-289
10.
Linearity and Response Time of the LHC Diamond Beam Loss Monitors in the CLEAR Beam Test Facility at CERN / Morales Vigo, Sara (CERN ; Cockcroft Inst. Accel. Sci. Tech.) ; Calvo Giraldo, Eva (CERN) ; Dyks, Luke (CERN) ; Effinger, Ewald (CERN) ; Farabolini, Wilfrid (CERN) ; Korysko, Pierre (CERN) ; Lernevall, Anders (CERN) ; Salvachúa, Belen (CERN) ; Welsch, Carsten (Cockcroft Inst. Accel. Sci. Tech.) ; Wolfenden, Joseph (Cockcroft Inst. Accel. Sci. Tech.) et al.
Chemical Vapour Deposition (CVD) diamond detectors have been tested during the Run 2 operation period (2015-2018) as fast beam loss monitors for the Beam Loss Monitoring (BLM) system of the Large Hadron Collider (LHC) at CERN. However, the lack of raw data recorded during this operation period restrains our ability to perform a deep analysis of their signals. [...]
2022 - 4 p. - Published in : JACoW IPAC 2022 (2022) 355-358 Fulltext: PDF;
In : 13th International Particle Accelerator Conference (IPAC 2022), Bangkok, Thailand, 12 - 17 Jun 2022, pp.355-358

Fant du ikke det du lette etter? Gjenta søket på andre tjenere:
recid:2674355 i Amazon
recid:2674355 i CERN EDMS
recid:2674355 i CERN Intranet
recid:2674355 i CiteSeer
recid:2674355 i Google Books
recid:2674355 i Google Scholar
recid:2674355 i Google Web
recid:2674355 i IEC
recid:2674355 i IHS
recid:2674355 i INSPIRE
recid:2674355 i ISO
recid:2674355 i KISS Books/Journals
recid:2674355 i KISS Preprints
recid:2674355 i NEBIS
recid:2674355 i SLAC Library Catalog