Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server Encontrados 2,047 registros  1 - 10siguientefinal  ir al registro: La búsqueda tardó 0.39 segundos. 
1.
Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter / CMS Collaboration
Tests of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than 0 .6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. [...]
CERN-EP-98-020.- Geneva : CERN, 1998 - 9 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 412 (1998) 223 Fulltext: PDF; - CERN library copies
2.
Low dose-rate irradiation set-up for scintillating crystals / D'Ambrosio, C ; Ercoli, C ; Jääskeläinen, S ; Rosso, E ; Wicht, P
CERN-PPE-96-172.- Geneva : CERN, 1997 - 23 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 388 (1997) 119-126 Fulltext: TIF PDF; - CERN library copies
3.
Control of lead tungstate crystals radiation hardness through optical transmission measurements / Annenkov, A N ; Auffray, Etiennette (CERN) ; Chipaux, Rémi ; Drobychev, G Yu ; Fedorov, A A ; Géléoc, M ; Golubev, N A ; Korzhik, M V ; Lecoq, P ; Lednev, A A et al.
1998
In : 7th International Conference on Calorimetry in High-energy Physics, Tucson, AZ, USA, 9 - 14 Nov 1997, pp.484-491
4.
Studies of lead tungstate crystal matrices in high energy beams for the CMS electromagnetic calorimeter at the LHC / CMS Collaboration
Using matrices of lead tungstate crystals energy resolutions better than 0.6% at 100 GeV have been achieved in the test beam in 1995. It has been demonstrated that a lead tungstate electromagnetic calorimeter read out by avalanche photodiodes can consistently achieve the excellent energy resolutions necessary to justify its construction in the CMS detector. [...]
CERN-PPE-96-148.- Geneva : CERN, 1997 - 22 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 385 (1997) 425-434 Fulltext: PDF; - CERN library copies
5.
Beam Tests of Lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter ; 1997 ed. / Auffray, Etiennette (CERN)
Further tests of lead tungstate crystal matrices made in high energy electron beams in 1996, using new crystals, new APDs and an improved test setup confirm that an energy resolution of better than 0.6% at 100 GeV can be obtained when the longitudinal uni formity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. [...]
CMS-NOTE-1997-099.- Geneva : CERN, 1997 Fulltext: PDF PS.Z;
6.
Results from tests on matrices of lead tungstate crystals using high energy beams / Peigneux, J P ; Schneegans, M ; Bateman, E ; Burge, S R ; Cockerill, D J A ; Connolly, J ; Smith, B ; Stephenson, R ; Auffray, Etiennette (CERN) ; Barney, D et al.
CERN-PPE-95-197.- Geneva : CERN, 1996 - 35 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 378 (1996) 410-426 Fulltext: PDF TIF; - CERN library copies
7.
Systematic Study of the PbWO4 Crystal Short Term Instalibity Under Irradiation / Annenkov, Alexander (Bogoroditsk Techno-Chemical Plant, Bogoroditsk, Russia) ; Auffray, Etiennette (CERN) ; Chipaux, Rémi (DAPNIA, Saclay, France) ; Drobychev, Gleb (LAPP, Annecy le Vieux, France) ; Fedorov, Andrey (Institute for Nuclear Problems, Minsk, Belarus) ; Géléoc, Marie (DAPNIA, Saclay, France) ; Golubev, Nikolai (Institute for Nuclear Research, Moscow, Russia) ; Korzhik, Mikhail (Institute for Nuclear Problems, Minsk, Belarus) ; Lecoq, Paul (CERN) ; Ligun, A B (Bogoroditsk Techno-Chemical Plant, Bogoroditsk, Russia) et al.
The effect of the irradiation on the lead tungstate ( PWO) scintillator properties has been studied at different irradiation facilities. Lead tungstate crystals grown with the tuning of oxides content in the melt to the stoichiometry of pure sheelite or sheelite-like type crystals and doped with heterovalent, trivalent and pentavalent impurities have been studied in order to optimize their resistance to irradiation. [...]
CMS-NOTE-1997-055.- Geneva : CERN, 1997 Fulltext: PDF PS.Z;
8.
The CMS calorimeter trigger / Heath, G P ; Ozorio d'Almeida, Alfredo M ; Buiron, L ; Busson, P ; Dasu, S ; Heath, H F ; Jaworski, M ; Lackey, J R ; Lecouturier, D ; Matricon, P et al.
1997
In : 3rd Workshop on Electronics for LHC Experiments, London, UK, 22 - 26 Sep 1997, pp.393-397
9.
Book cover CMS experiment at LHC / Alexeev, G
Geneva : CERN, 1997. - 15 p.

10.
Book cover A compact solenoidal detector for LHC / Alexeev, G
Geneva : CERN, 1997. - 11 p.


¿No ha encontrado lo que estaba buscando? Intente su búsqueda en:
recid:351240 en Amazon
recid:351240 en CERN EDMS
recid:351240 en CERN Intranet
recid:351240 en CiteSeer
recid:351240 en Google Books
recid:351240 en Google Scholar
recid:351240 en Google Web
recid:351240 en IEC
recid:351240 en IHS
recid:351240 en INSPIRE
recid:351240 en ISO
recid:351240 en KISS Books/Journals
recid:351240 en KISS Preprints
recid:351240 en NEBIS
recid:351240 en SLAC Library Catalog