Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 2,042 εγγραφές βρέθηκαν  1 - 10επόμενοτέλος  μετάβαση στην εγγραφή: Η έρευνα πήρε 0.63 δευτερόλεπτα. 
1.
Proton therapy treatment monitoring with the DoPET system: activity range, positron emitters evaluation and comparison with Monte Carlo predictions / Muraro, S (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Bisogni, M G (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Cristoforetti, L (Trento Hospital, Trento) ; Guerra, A Del (Pisa U. ; INFN, Pisa) ; Ferrari, A (CERN) ; Fracchiolla, F (Trento Hospital, Trento) ; Morrocchi, M (Pisa U. ; INFN, Pisa) et al.
Ion beam irradiations can deliver conformal dose distributions minimizing damage to healthy tissues thanks to their characteristic dose profiles. Nevertheless, the location of the Bragg peak can be affected by different sources of range uncertainties: a critical issue is the treatment verification. [...]
2017 - 10 p. - Published in : JINST 12 (2017) C12026
In : 19th International Workshop on Radiation Imaging Detectors, Krakow, Poland, 2 - 6 Jul 2017, pp.C12026
2.
Low statistics positron activity reconstruction methods for proton therapy / Muraro, S (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Bisogni, M G (INFN, Pisa ; Pisa U.) ; Cristoforetti, L (Unlisted, IT) ; Del Guerra, A (Pisa U. ; INFN, Pisa) ; Ferrari, A (CERN) ; Fracchiolla, F (Unlisted, IT) ; Kraan, A (Pisa U. ; INFN, Pisa) et al.
Positron emission tomography (PET) is one of the most mature techniques for monitoring in ion beam therapy. PET allows to reconstruct the β$^{+}$ activity generated in the patient by the nuclear interaction of the ions. [...]
2019 - 2 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 936 (2019) 52-53
In : Frontier Detectors for Frontier Physics: XIV Pisa Meeting on Advanced Detectors, La Biodola, Isola D'elba, Italy, 27 May - 2 Jun 2018, pp.52-53
3.
Monitoring Proton Therapy Through in-Beam PET: An Experimental Phantom Study / Topi, A (INFN, Pisa) ; Muraro, S (INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (INFN, Pisa ; Pisa U.) ; Bisogni, M G (INFN, Pisa ; Pisa U.) ; Camarlinghi, N (INFN, Pisa ; Pisa U.) ; Del Guerra, A (INFN, Pisa ; Pisa U.) ; Ferrari, A (CERN) ; Kopec, R (Cracow, INP) ; Kraan, A C (INFN, Pisa) et al.
In this paper, we investigate the use of a positron emission tomography (PET) system to monitor the proton therapy. The monitoring procedure is based on the comparison between the β+ activity generated in the irradiated volume during the treatment, with the β+ activity distribution obtained with Monte Carlo (MC) simulation. [...]
2020 - 8 p. - Published in : IEEE Trans. Rad. Plasma Med. Sci. 4 (2020) 194-201
4.
Online monitoring for proton therapy: A real-time procedure using a planar PET system / Kraan, A C (Pisa U. ; INFN, Pisa) ; Battistoni, G (INFN, Milan) ; Belcari, N (Pisa U. ; INFN, Pisa) ; Camarlinghi, N (Pisa U. ; INFN, Pisa) ; Ciocca, M (CNAO, Pavia) ; Ferrari, A (CERN) ; Ferretti, S (Pisa U. ; INFN, Pisa) ; Mairani, A (CNAO, Pavia) ; Molinelli, S (CNAO, Pavia) ; Pullia, M (CNAO, Pavia) et al.
In this study a procedure for range verification in proton therapy by means of a planar in-beam PET system is presented. The procedure consists of two steps: the measurement of the β+-activity induced in the irradiated body by the proton beam and the comparison of these distributions with simulations. [...]
2015 - Published in : Nucl. Instrum. Methods Phys. Res., A 786 (2015) 120-126 Elsevier Open Access article: PDF;
5.
Measurement of PET isotope production cross sections for protons and carbon ions on carbon and oxygen targets for applications in particle therapy range verification / Horst, Felix (Darmstadt, GSI ; Mittelhessen U., Giessen) ; Adi, Wihan (Mittelhessen U., Giessen ; Giessen U.) ; Aricò, Giulia (CERN) ; Brinkmann, Kai-Thomas (Giessen U.) ; Durante, Marco (Darmstadt, GSI ; Darmstadt, Tech. U.) ; Reidel, Claire-Anne (Darmstadt, GSI ; Strasbourg, IPHC) ; Rovituso, Marta (TIFPA-INFN, Trento ; Unlisted, NL) ; Weber, Uli (Darmstadt, GSI) ; Zaunick, Hans-Georg (Giessen U.) ; Zink, Klemens (Frankfurt U., FIAS ; Mittelhessen U., Giessen ; U. Hospital, Giessen-Marburg) et al.
Measured cross sections for the production of the PET isotopes , and from carbon and oxygen targets induced by protons (40–220 ) and carbon ions (65–430 ) are presented. These data were obtained via activation measurements of irradiated graphite and beryllium oxide targets using a set of three scintillators coupled by a coincidence logic. [...]
2019 - 16 p. - Published in : Phys. Med. Biol. 64 (2019) 205012 Fulltext: PDF;
6.
The FLUKA code for application of Monte Carlo methods to promote high precision ion beam therapy / Parodi, K (Heidelberg Ion Therapy Center) ; Brons, S (Heidelberg Ion Therapy Center) ; Cerutti, F (CERN) ; Ferrari, A (CERN) ; Mairani, A (Heidelberg Ion Therapy Center ; INFN, Milan) ; Paganetti, H (Massachusetts General Hospital) ; Sommerer, F (Heidelberg Ion Therapy Center ; CERN)
Monte Carlo (MC) methods are increasingly being utilized to support several aspects of commissioning and clinical operation of ion beam therapy facilities. In this contribution two emerging areas of MC applications are outlined. [...]
2010 Published version from CERN: PDF;
In : 12th International Conference on Nuclear Reaction Mechanisms, Villa Monastero, Varenna, Italy, 15 - 19 Jun 2009, pp.509-516
7.
INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy / Bisogni, Maria Giuseppina (U. Pisa (main)) ; Attili, Andrea (U. Turin (main)) ; Battistoni, Giuseppe (INFN, Italy) ; Belcari, Nicola (U. Pisa (main)) ; Camarlinghi, Niccoló (U. Pisa (main)) ; Cerello, Piergiorgio (INFN, Italy) ; Coli, Silvia (INFN, Italy) ; Del Guerra, Alberto (U. Pisa (main)) ; Ferrari, Alfredo (CERN) ; Ferrero, Veronica (U. Turin (main)) et al.
The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. [...]
2016 - 12 p. - Published in : Journal of Medical Imaging 4 (2016) 011005
8.
Ion charge separation with new generation of nuclear emulsion films / Montesi, M.C. (Naples U. ; INFN, Naples) ; Lauria, A. (Naples U. ; INFN, Naples) ; Alexandrov, A. (INFN, Naples ; Naples U. ; Natl. U. Sci. Tech., Moscow ; Lebedev Inst.) ; Solestizi, L. Alunni (INFN, Perugia ; Perugia U.) ; Giovanni, Ambrosi (INFN, Perugia) ; Argirò, S. (Turin U. ; INFN, Turin) ; Diaz, R. (Havana, CEADEN) ; Bartosik, N. (INFN, Turin) ; Battistoni, G. (INFN, Milan) ; Belcari, N. (Pisa U. ; INFN, Pisa) et al.
In hadron therapy, the accelerated ions, interacting with the body of the patient, cause the fragmentation of both projectile and target nuclei. The fragments interact with the human tissues depositing energy both in the entrance channel and in the volume surrounding the tumor. [...]
2019 - 8 p. - Published in : Open Physics 17 (2019) 233-240 Fulltext: PDF;
9.
The FOOT FragmentatiOn Of Target Experiment / Alexandrov, Andrey (INFN, Naples) ; Alpat, Behcet (INFN, Perugia) ; Ambrosi, Giovanni (INFN, Perugia) ; Argirò, Stefano (Turin U. ; INFN, Turin) ; Battistoni, Giuseppe (INFN, Milan) ; Bisogni, Maria Giuseppina (Pisa U. ; INFN, Pisa) ; Belcari, Nicola (Pisa U. ; INFN, Pisa) ; Biondi, Silvia (INFN, Bologna ; Bologna U.) ; Bruni, Graziano (INFN, Bologna) ; Camarlinghi, Niccolò (Pisa U. ; INFN, Pisa) et al.
In proton-therapy clinical practice a constant RBE equal to 1.1 is adopted, regardless of the demonstrated RBE variations, which depends on physical and biological parameters. Among other mechanisms, nuclear interactions might influence the proton-RBE due to secondary heavier particles produced by target fragmentation that can significantly contribute to the total dose: an un-wanted and undetermined increase of normal tissues complications probability may occur. [...]
Geneva : CERN, 2019 - 8 p. - Published in : CERN Proc.: 1 (2019) , pp. 305-312 Fulltext: PDF;
In : 15th International Conference on Nuclear Reaction Mechanisms, Varenna, Italy, 11 - 15 Jun 2018, pp.305-312
10.
Delivery, Beam and Range Monitoring in Particle Therapy in a Highly Innovative Integrated Design / Bottura, L (CERN) ; Felcini, E (CERN ; Ecole Polytechnique, Lausanne) ; Ferrero, V (INFN, Turin) ; Fiorina, E (INFN, Turin) ; Monaco, V (Turin U. ; INFN, Turin) ; Pennazio, F (INFN, Turin) ; de Rijk, G (CERN) ; Cerello, P (INFN, Turin)
The design of a particle therapy system that integrates an innovative beam delivery concept based on a static toroidal gantry and an imaging configuration suitable for beam and online range monitoring is proposed and discussed. Such approach would provide a compact and cost-effective layout, with a highly flexible and fast beam delivery, single particle counting capability for fast measurement of beam fluence and position and a precise real time verification of the compliance between the treatment delivery and its prescription. [...]
2020 - Published in : Front. Phys. 8 (2020) 566679 Fulltext: PDF;

Δεν βρήκατε αυτό που αναζητούσατε; Δοκιμάστε την έρευνά σας σε άλλους servers:
recid:2320584 σε Amazon
recid:2320584 σε CERN EDMS
recid:2320584 σε CERN Intranet
recid:2320584 σε CiteSeer
recid:2320584 σε Google Books
recid:2320584 σε Google Scholar
recid:2320584 σε Google Web
recid:2320584 σε IEC
recid:2320584 σε IHS
recid:2320584 σε INSPIRE
recid:2320584 σε ISO
recid:2320584 σε KISS Books/Journals
recid:2320584 σε KISS Preprints
recid:2320584 σε NEBIS
recid:2320584 σε SLAC Library Catalog