Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 5 record trovati  La ricerca ha impiegato 0.52 secondi. 
1.
Determination of fission barrier height of $^{210}$Fr and $^{210}$Ra via neutron measurement / Veselský, M (IEAP CTU, Prague) ; Rubovič, P (IEAP CTU, Prague) ; Petousis, V (IEAP CTU, Prague) ; Natal da Luz, H (IEAP CTU, Prague) ; Burian, P (IEAP CTU, Prague) ; Mánek, P (IEAP CTU, Prague) ; Meduna, L (IEAP CTU, Prague) ; Smolyanskiy, P (IEAP CTU, Prague) ; Raabe, R (Leuven U.) ; Camaiani, A (Leuven U.) et al.
Fission barrier heights of short-lived nuclei away from line of β stability are not known reliably. Low-energy fission of Fr210 and Ra210, produced by (d,p) and (d,n) transfer reaction on the re-accelerated unstable beam Fr209 was investigated at HIE-ISOLDE. [...]
2024 - 6 p. - Published in : Phys. Rev. C 109 (2024) 014618 Fulltext: PDF;
2.
Timepix3 as solid-state time-projection chamber in particle and nuclear physics / MOEDAL Collaboration
Timepix3 devices are hybrid pixel detectors developed within the Medipix3 collaboration at CERN providing a simultaneous measurement of energy (ToT) and time of arrival (ToA) in each of its 256$\times$256 pixels (pixel pitch: 55 µm). The timestamp resolution below 2 ns allows a measurement of charge carrier drift times, so that particle trajectories can be reconstructed in 3D on a microscopic level ($z$-resolution: 30-60 µm). [...]
SISSA, 2021 - 8 p. - Published in : PoS ICHEP2020 (2021) 720 Fulltext: PDF;
In : 40th International Conference on High Energy Physics (ICHEP), Prague, Czech Republic, 28 Jul - 6 Aug 2020, pp.720
3.
Registration of the transition radiation with GaAs detector: Data/MC comparison / Alozy, J (CERN) ; Belyaev, N ; Bergmann, B L (IEAP CTU, Prague) ; Billoud, T R V (IEAP CTU, Prague) ; Broulim, P (Pilsen, Coll. Mech. Elect. Eng.) ; Burian, P (IEAP CTU, Prague ; Pilsen, Coll. Mech. Elect. Eng.) ; Campbell, M (CERN) ; Chelkov, G (Dubna, JINR) ; Cherry, M (Louisiana State U.) ; Dachs, F (CERN) et al.
New developments of pixel detectors based on GaAs sensors offer effective registration of the transition radiation (TR) X-rays and perform simultaneous measurements of their energies and emission angles. This unique feature opens new possibilities for particle identification on the basis of maximum available information about generated TR photons. [...]
2020 - 8 p. - Published in : J. Phys.: Conf. Ser. 1690 (2020) 012041 Fulltext: PDF;
In : 5th International Conference on Particle Physics and Astrophysics (ICPPA), Moscow, Russian Federation, 5 - 9 Oct 2020, pp.012041
4.
Particle tracking and radiation field characterization with Timepix3 in ATLAS / Bergmann, B (IEAP CTU, Prague) ; Billoud, T (IEAP CTU, Prague) ; Burian, P (IEAP CTU, Prague ; Pilsen U.) ; Leroy, C (Montreal U.) ; Mánek, P (IEAP CTU, Prague ; University Coll. London) ; Meduna, L (IEAP CTU, Prague ; Pilsen U.) ; Pospíšil, S (IEAP CTU, Prague) ; Suk, M (IEAP CTU, Prague) /ATLAS Collaboration
Four hybrid pixel detectors of Timepix3 technology, installed in the ATLAS experiment, were continuously taking data from April 2018 until the end of the Run-2 data taking period (December 2019). These detectors are synchronized with each other and the LHC orbit clock. [...]
2020 - 5 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 978 (2020) 164401
In : 12th international "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD), Hiroshima, Japan, 14 - 18 Dec 2019, pp.164401
5.
Transition radiation measurements with a Si and a GaAs pixel sensor on a Timepix3 chip / Dachs, F (CERN ; TU Vienna) ; Alozy, J (CERN) ; Belyaev, N (Moscow Phys. Eng. Inst.) ; Bergmann, B L (CTU, Prague) ; van Beuzekom, M (Nikhef, Amsterdam) ; Billoud, T R V (Montreal U.) ; Burian, P (CTU, Prague ; Pilsen, Coll. Mech. Elect. Eng.) ; Broulim, P (Pilsen, Coll. Mech. Elect. Eng.) ; Campbell, M (CERN) ; Chelkov, G (Dubna, JINR) et al.
Growing energies of particles at modern or planned particle accelerator experiments as well as cosmic ray experiments require particle identification at gamma-factors ($\gamma$) of up to ∼ 10$^5$ . At present there are no detectors capable of identifying charged particles with reliable efficiency in this range of $\gamma$ . [...]
Elsevier, 2020 - 4 p. - Published in : Nucl. Instrum. Methods Phys. Res., A 958 (2020) 162037
In : 15th Vienna Conference on Instrumentation, Vienna, Austria, 18 - 22 Feb 2019, pp.162037

Vedi anche: autori con nomi simili
1 Meduna, Lukas
Sei interessato ad essere notificato su nuovi risultati di questa ricerca?
Imposta un avviso via mail personale o iscriviti al feed RSS.
Non hai trovato quello che cercavi? Prova la ricerca su altri server:
Meduna, L in Amazon
Meduna, L in CERN EDMS
Meduna, L in CERN Intranet
Meduna, L in CiteSeer
Meduna, L in Google Books
Meduna, L in Google Scholar
Meduna, L in Google Web
Meduna, L in IEC
Meduna, L in IHS
Meduna, L in INSPIRE
Meduna, L in ISO
Meduna, L in KISS Books/Journals
Meduna, L in KISS Preprints
Meduna, L in NEBIS
Meduna, L in SLAC Library Catalog
Meduna, L in Scirus