SG TL AND LHB 16-01-2025
SG TL AND LHB 16-01-2025
SG TL AND LHB 16-01-2025
BY
C.RAJA MOHAN
ESTC/LGD/SCR ADEE/M/KZJ
1
TYPES OF TRAIN LIGHTING SYSTEMS
2
Advantages of SG
3
Disadvantages of SG
• Bulky 120 Ah coach battery required as power is not generated during standby / slow
movement .
4
End On Generating System
Provided on Rajdhani, Shatabdi, Duronto, Garibeachrath type fully AC
trains with large power requirements.
5
End On Generating System
Power is fed through feeders to IV couplers, ZS couplers
400Amps either side of coaches one end power car to other
power car .
Garibrath and old rajadhani coaches Light & fans work on 110V
AC which is step down by 3 KVA transformer.
6
END ON GENERATING SYSTEM
FEEDER - I
ALT. ALT. ALT. ALT.
COACHES COACHES
FEEDER - II
GENERATOR GENERATOR
CAR CAR
COACH SUPPLY
750 V, 3 Ø AC
FEEDER LOAD
415 V, 3 Ø
50/60kVA TRANSFORMER 415 V, 3 Ø
LIGHTING TRANSFORMER
110 V, 3 Ø
LIGHTING LOAD
7
End on Generating System
8
Advantages EOG System
No restriction of Load due to high capacity power cars.
Standby DA sets.
10
Head On Generation
ESTC/LGD SC RLY 11
Head ON Generation(HOG)
is step towards Energy Efficiency
Indian Railways imported 22 no. of WAG-9 locomotives and 11 no. of WAP-5 locomotives from M/s.
ABB Switzerland in 1996-97.
Chittaranjan Loco Works stared the production of WAP-7 is actually a modified version of WAG-9
freight locomotive.
A hotel load winding in locomotive transformer of WAP-5 and WAP-7 has been provided to cater the
hotel load supply to the coaches through hotel load converter .
12
Head ON Generation(HOG)
is step towards Energy Efficiency
Implementation of HOG scheme as per Railway board letter no. 95/elect(G)/114/13 Ptdtd.25/10/07.
Manufacturing of 3 phase electric loco having minimum 2X500KVA hotel load converters with IGBT
technology.
First HOG loco NO: WAP-7 is 30277 is manufactured on July 2010 .
First train no:12005/06 Shatabdhi Exp NDLS to KLK run with M/s Siemens make 2X500 KVA converter
on 21-02-2011.
13
HOG
Indian railways has decided to adopt an energy efficient power supply to coaches.
Presently system is running with End on Generation (EOG) in LHB type coaches.
14
HOG
The out put voltage of hotel load winding is 960 Volts single phase 50 Hz.
15
MAJOR EQUIPMENTS IN SG TL COACHES
• ALTERNATOR (4.5KW)
• RRU/ERRU (4.5KW)
• V-BELT
• AXLE PULLEY
• BATTERIES
Purpose of ALT:
• Charging the coach battery on train run
DESIGN
17
Alternators- Key parameters
Feature 4.5 kW
Insulation class F
18
Alternators – Key parameters
Weight (max) NM
2)IR values of TL/AC coach should not be less than ---MΩ in fair weather ( )
A)1 B)2 C) 3 D)10
3) The voltage setting of Alt/RR unit is to be set in far with current and RPM for 4.5KW is ( )
A) Half rated capacity of the alt as load as 1500 RPM
B) ¼ rated capacity of the alt as load at 1000 RPM
C) Full rated capacity of alt as load at 2550 RPM
D) None of the above
20
Sample Questions
5)Rating of main fuses to be provided in 4.5kw MA type RR unit ()
A) 35A HRC B) 160A HRC C)Either A & B D)None
21
SAMPLE QUESTIONS
22
SAMPLE QUESTIONS
4)The alternator of SG TL Coach leaving primary depot should have how many belts ( )
A) 4 B)3 C)
2 D)1
5) The capacity of alternator of 3Tier sleeper Coach is a ()
A)25kW B)18kW C) 4.5kW D)7.5kW
25
REGULATOR CUM RECTIFIER UNIT(RRU)
26
PULLEY
27
Sample Questions
A) 63 A B) 40 A C) 32 A D) 16 A
A) 63 A B) 40 A C) 32 A D) 16 A
A) 63 A B) 40 A C) 32 A D) 16 A
A) 19 B)18 C) 57 D) 54
A) 4 B) 12 C) 6 D)3
11)Battery Rating of ELU in SG TL Coach ()
A) 6V 120AH B)12V 12AH C)2V 1100 AH D) NONE OF THE ABOVE
29
AXLE PULLY
Description Particulars
4.5 KW Axle pulley – dia (pcd) width 572.6 ± 0.4 mm
200 ± 1 mm
30
V-BELT
Type: C-122
TOP RUBBER
BASE RUBBER
RUBBER IMPREGNATED
FABRIC JACKET
40º
INCLUDED ANGLE
V BELT KEY PARAMETERS
• Angle = 40 degrees
33
PROTECTIVE DEVICES in SG AC RMPU COACHES
34
REGULATOR CUM RECTIFIER UNIT(RRU)
35
Sample Questions
2)Expand ERRU ()
A) Electronic Rectifier cum Regulator unit
B) Electromagnetic Rectifier cum Regulator unit
C) Electro static Regulator Rectifier unit
D) None of the above
3) The voltage setting of Alt/RR unit is to be set in far with current and RPM for 4.5KW is
()
A) Half rated capacity of the alt as load as 1500 RPM
B) ¼ rated capacity of the alt as load at 1000 RPM
C) Full rated capacity of alt as load at 2550 RPM
D) None of the above
36
Sample Questions
5)Rating of main fuse to be provided in 4.5kw MA type RR unit ()
A) 35A HRC B) 160A HRC C)Either A & B D)None
9)IGBT is ()
A) Fast switching device B)Slow switching device 37
C) Very fast switching device D) None
RJB
• FUSES….6A,16A,40A.
• RSW(40A)…….L-I,L-II,FAN,SPM
• CIRCUITS…..L-I,L-II,FAN,EFT,PACIL,ELU.
38
RJB
L-I CIRCUIT
L-II CIRCUIT
DIFFERENT LIGHTS
COMPARTMENT LIGHTS
NIGHT LIGHTS
GANGWAY LIGHTS
TOILET LIGHTS
DOORWAY LIGHTS
39
ILLUMINATION LEVELS
40
FDB
The branch circuits for lights and fans shall be protected by re wirable tinned
copper fuses.
These re wirable fuses shall be located on a distribution fuse board and all branch
circuits shall be protected by fuses on both negative and positive sides.
Types of fans
2. Abbreviation of BLDC ( )
A. Brushless direct current B. Bearing less direct current C. Brushless dynamo current D. None
• Purpose is to feed emergency supply from one coach to another coach in case of
failure.
• Each coach has 4 EFTs.
• Provided on end body.
• EFT has positive and negative terminals.
ELU
MAKES
• AMARRAJA
• HBL
• EXIDE
• MICROTEX
• SOUTHERN
Sample Questions
8 Wheelset earthing
equipment for high Not provided Provided
life of axle bearing
Exterior view of LHB EOG NON Interior view of LHB EOG NON
AC 3 Tier Sleeper Coaches AC 3 Tier Sleeper Coaches
61
Friday 7 February 2025 ESTC/LGD/SCR
IV COUPLER WITH JUNCTION BOX
MAIN PINS
LIMIT SWITCH
(FOR CONTROL
PINS / SAFETY
LOOP)
RATCHET ASSY
FOR HOLDING
THE PLUG
END WALL
DUMMY
SOCKET
RATCHET
ASSEMBLY
IV COUPLER-500A IV COUPLER-400A
1. Phase sequence
2. Phase failure
3. Phase unbalance
4. Under voltage
5. Over voltage
Both types of the transformers are star- star-star connected, dry type and air cooled.
Output current -------- (1) 6.26 A for 4.5 KVA winding at 415V.
(2) 13.67 A for 4.5KVA winding at 190V.
Output current -------- (1) 14.60 A for 10.5 KVA winding at 415V.
(2) 13.67 A for 4.5KVA winding at 190V.
9 KVA Transformer:
15 KVA Transformer:
There are 2 No.s of 100 VA Control transformers available in LHB Non AC coach.
Technical specification:
Input voltage…….750 V AC
Output voltage…..110 V AC
Class of Insulation….. H class
Weight……..4.5 Kg (max.)
Fuse ratings:
Input fuses…. 2A, 1.2 KV (2 No.s)
Output fuses... 2A, 500V (2 No.s)
Technical specifications:
Input voltage------ 3- phase,4-wire, 415 V AC (Min.350V- Max.480 V)
During normal operation of battery charging , the output voltage setting is 122 V ±2%
Technical specifications:
Input voltage------ Single phase, 240 V ± 15% AC
Output voltage--110V ± 5% DC
Output current------22 A
or VL=Vph x
ALT_1 ALT_3
BC
BC
FJB IV COUPLER FJB FJB IV COUPLER FJB FJB IV COUPLER FJB
ALT_2 ALT_4
1 PHASE
1 PHASE
INTERLOCKING 750V/110V AC
750V/110V AC
MMR MMR 100VA HOG
100VA HOG
K-03 K-04 TRANSFORMER
TRANSFORMER
K-01 K-02
CONTACTOR CONTACTOR
Y-Y
3 PHASE
750V/190V+415V AC
SERIES RESISTOR 9KVA POWER SERIES RESISTOR
TRANSFORMER
CAPACITOR FILTER CAPACITOR FILTER
FOR HOG FOR HOG
16A HRC 3 PHASE 190V 3 PHASE 415V 25A HRC
FUSES AC SUPPLY FUSES
RC
AC SUPPLY
. RC
FILTER FILTER
LAVATORTY PUMP
FOR MCS-MOBILE URBC MOTOR
EXHAUST FANS AEL-ACCIDENTAL EMERGENCY LIGHTS
CHARGING 1&2
SOCKETS PUMP CONTROLLER
BETWEEN ONE
ANTI SKID DEVICE
PHASE AND 40A HRC
NEUTRAL 110V AC FUSE COACH LIGHTS
DC BRUSHLESS FANS
CONTROL
TOWARDS 9 TRANSFORMER
2A MMR
2A
KVA NET-1 K-03
TRANSFORMER
NET-1 CONTACTOR K-01 FEEDER-1
25A
CONTACTOR 25A
K-01 25A
S
D&ED
NET-2 CONTACTOR K-02
HRC FUSES 750 V
25A
CONTACTOR 25A
K-02 25A
N FEEDER-2
CONTROL 2A MMR
TRANSFORMER
NET-2
2A K-04
16A
25A
16A
16A
25A
25A
20A FUSE Y
20A FUSE B
TO ROTARY
TO BATTERY
JUNCTION
CHARGER
BOX
N
POWER CIRCUIT DIAGRAM
NC – NORMALLY CLOSE
NO – NORMALLY OPEN
POWER ON/OFF NET-1/2 SELECTOR
ROTARY ROTARY
NO
P A-2 A-1
25A
I/P (750V) O/P (110V) 25A A NC 1
2A
K-01_COIL 25A
N D&D AUXILIARY
CONTACT
NET_1 CONTACTOR K-01
2A
2A
• Rail Madad is a mobile app to register complaints by passengers through mobile phone.
• Rail Madad is linked with Railways existing ticketing system like PRS
• Rail Madad is a single portal for grievance inquiry and assistance for all railway costumers.
• Electrical Complaints registered the following cases in Rail Madad Portal
126
LIST OF MUST CHANGE ITEMS FOR NON AC LHB COACHES