WHAT IS A CONDOMINIUM?
A condominium (or condo) is a building complex containing a number of
individually owned apartments with shared facilities.

WHAT IS A CO-WORKING SPACE?


Coworking space is basically a type of workplace where we share the same
work environment, thus making a community in the same area.
 Coworking spaces are designed to provide a productive and collaborative
environment for their dynamic inhabitants, and created without corporate
constraints on what is perceived to be an “office” environment offering
flexible memberships to suit most needs.
Spatial analysis
USER DETAILS
Both males and females
Age group : 18-35 years

• REQUUIRMENT
1. Studio apartments
2. Condominium rooms
Living room
dining space
kitchen and pantry
bedroom
toilet
3. Co working space
lobby
workspace
meeting rooms
toilets
4. Recreation area
swimming pool, indoor and outdoor play area, café etc.
KITCHEN

• Every kitchen must have provision for washing


utensils, with proper connection to drainage.
• The kitchen must be provided with an impermeable
floor.
• The kitchen must open into an interior or exterior
open space and should not be less than one sq metre.
• The kitchen should not open into a shaft.
• No chutes to be used in buildings above 15 metres.
TOILET
• Bath and WC (combined): 1800mm X 1800mm to 1800mm X 2500mm
• Bathroom (separate): 1200mm X 1800mm
• WC (separate): 1200mm X 1200mm 

Every bathroom or water closet shall


a) Be so situated that atleast one of its walls shall open to external air
and shall have a minimum opening in the form of window or ventilation
to the extent of 0.37 sq m.
b) Not be directly over any room other than another latrine, washing
place, bath or terrace unless it has a watertight floor.
c) Have the platform or seat made of watertight non-absorbent
material.
d)Be provided with an impervious floor covering, sloping towards the
drain with a suitable grade and not towards verandah or any other
room.
e)All the sewage outlets shall be connected to the Municipal Sewerage
system. Where no such system exists, a septic tank shall be provided
within the plot conforming to the requirements.
RECREATION SPACES
GYM
• Swimming pool
• The area around the pool can be designed with wood or
stone decking, with either natural or synthetic wood or
natural or tiled stone depending on the preferred style
and maintenance.
WORKING SPACE
CONFERENCE ROOM
65-80cm for every chair when positioning the chairs around the
meeting table min/max
110-140cm between the meeting table and the wall min/max
40cm minimum between back of chair (when pushed-in) and the
wall
50-70cm between the back of the chair and the wall to walk
without having to turn sideways
PERSONAL WORKSPACE
Minimum workspace required for each person : 2.5 sq.m
• VERTICAL CIRCULATION
CIRCULATION • STAIRCASE:
min. width of stairs for residential flat: 1.25m
• An efficient floor plan of a multi-apartment building will
The minimum headroom in a passage under the landing of a staircase and
have a circulation area of 11 to 15% of Floor Plate area - under the staircase shall be 2.2 m.
circulation area, but should not exceed 20%. This
Interior stairs shall be constructed of non-combustible material
Includes area for Lift lobby and staircase. throughout.
• ELEVATORS
HORIZONTAL CIRCULATION 1. There should be one elevator for every 90 units. A maximum of 150
feet from
Includes corridors, entrance, lobby the elevators to the farthest elevator is a must.

etc 2. City apartments and really high priced units can require an elevator for
every 50 – 60 units.
3. Always have an elevator with higher ceilings (9 feet) and higher weight
capacity (3500 lbs) for moving furniture and heavy items. If you are
over 10 floors, a service elevator or small freight elevator should be
considered.
The NBC has guidelines for the entry, as well as exit points in
• DCR DETAILS buildings.
• Total site area: 13595 sq.m • An exit must be provided in every building, so as to permit
safe escape of residents in times of fire or earthquakes, etc.
• Open space reservation [OSR] :  1359.5 sq.m
• Exits are compulsory and these should be clearly visible to
• Plot coverage :  60% = 7342 sq.m all and must be illuminated. These cannot be reduced in
number, width or by any other means. The requisite
• Maximum FSI: 1.5 number is dependent on occupancy load, capacity, travel
• Maximum Build up area: 14274.75 sq.m distance, etc.

• Maximum height of the building:. 15m • Alarms are necessary to ensure those in danger are
evacuated promptly.
• Setback: minimum 3m • Exits should be continuous, leading to the exterior of the
• Corridor width: 1.25m (min) building.
• Exits can be horizontal or vertical.
• Lifts and revolving doors are not exits.
SERVICES
• Parking
• PARKING
• Electricity • the minimum size of a car
• Water supply and drainage parking space is 2.5 m (8'2”)
• Fire safety -  automatic fire detection and alarm wide and 5 m (16'4”) long.
facilities are a must and should be provided. Not just
this, buildings should be provided with and • minimum area required for car
protected by fire extinguishers, wet risers, automatic
sprinkler installations, etc.  parking: 12.5 sq.m
• Emergency exit
• Electric room
• Waste water treatment plant
• Elevators
• Ventilation shaft
• Lightning protection :  TheLightning Conductor
which is also known as Lightning Rod or Air Terminal
is one of the best known forms of shielding device
and has been in use in protecting buildings and
facilities where protection is mandatory.