Materi Trouble Shooting
Materi Trouble Shooting
Materi Trouble Shooting
NIS : 70218105
RI 1999
TTG : BLITAR,17 JANUA
KELAS : G
RTA
ASAL : UT SCHOOL JAKA
MATERI
TROUBLE SHOOTING
* Sebagai salah satu syarat kelulusan Ut School
* Karena pentingnya menemukan apa penyebab
trouble
N G
L A KA
R BE
TA Memahami cara troubleshooting pada suatu unit
AN
JU
TU
PREPARE TOOLS AND SAFETY PROSEDUR
DATA UNIT
Site
Site :: BINUNGAN
BINUNGAN BLOK
BLOK 8
8
Model
Model Unit
Unit :: HD
HD 785-7
785-7
Machine
Machine S/N
S/N :: 32338
32338
Code
Code Number
Number Unit
Unit :: DT
DT 4896
4896
Model
Model Engine/ESN
Engine/ESN :: SAA12V140-3
SAA12V140-3 // 510531
510531
Costumer
Costumer :: PT.
PT. Pama
Pama Persada
Persada Nusantara
Nusantara
Trouble
Trouble :: CB1552
CB1552
Trouble
Trouble Date
Date :: 24
24 JANUARI
JANUARI 2019
2019 12:00
12:00
Correted
Correted Date
Date :: 24
24 JANUARI
JANUARI 2019
2019 17:00
17:00
POSSIBILITIES CAUSES
Wiring injector
Defective injector
Defective engine controller
Ground foult wiring harnes
Connector broken
OBSERVE & DIAGNOSTIC
46 60
60
M
Child j1 Controller
Conector
CHECK DISCONNECTION WIRING
Female child j1 46 Ground foult wiring
dengan CN5 L 1.3 Ω 46-CN5 1 :ol (ok)
(Not ok)
Female child 60
dengan CN5 M : 0 Ω Ground foult wiring 60-
ok) CN5 2 : ol (ok)
Pengecekan visual
terdapat connector pin
tenggelam
CHECK DEVECTIVE ENGINE CONTROLLER AND
DEFECTIVE INJECTOR
Dari data pengukuran yang sesuai standart ditemukan salah satu pengukuran yang tidak
sesuai, dan pada saat pengecekan visual terdapat connector pin yang tenggelam.
CONCLUSION
CB1552
SUSPECTED CAUSE
REFERENSI
Shop manual HD 785-7 SN 30001 UP
Parts book
TE R I
MA K
ASIH