3031 PDF
3031 PDF
3031 PDF
1 Adjustment conditions
CAT Designation Unit Set value min. max. Actual values OT
Test oil ISO4113orSAEJ967
d
1404 Test oil
P Test oil temperature degC 45 45 50
Nozzle 105780-0060
Bosch type code NP-DN0SD1510
Nozzle holder 105780-2150
P Opening pressure MPa 13 13 13.3
P Opening pressure kgf/cm2 133 133 136
Injection pipe 157805-7320
P Injection pipe mm 2-6-450
Inside diameter - outside diameter - length (mm)
Joint assembly 157641-4720
Tube assembly 157641-4020
P Transfer pump pressure kPa 20 20 20
P Transfer pump pressure kgf/cm2 0.2 0.2 0.2
Direction of rotation (viewed from drive side) R
Right
2 Adjustment specification
2.1 Full load delivery
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 1000 1000 1000
S Average injection quantity mm3/st. 46.7 46.2 47.2
S Difference in delivery mm3/st. 4 4
P Basic *
P Oil temperature degC 50 48 52
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 400 400 400
C Average injection quantity mm3/st. 42.2 38.2 46.2
About
P Oil temperature degC 48 46 50
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 600 600 600
C Average injection quantity mm3/st. 44.2 40.2 48.2
About
P Oil temperature degC 50 48 52
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 1000 1000 1000
C Average injection quantity mm3/st. 46.7 45.7 47.7
C Difference in delivery mm3/st. 4.5 4.5
P Basic *
P Oil temperature degC 50 48 52
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 1100 1100 1100
C Average injection quantity mm3/st. 45.3 35.3 48.8
About
P Oil temperature degC 50 48 52
2.2 Governing
CAT Designation Unit Set value min. max. Actual values OT
P Pump speed r/min 1225 1225 1225
S Average injection quantity mm3/st. 9 7 11
S Difference in delivery mm3/st. 3 3
P Basic *
3 Assembly dimension
CAT Designation Unit Set value min. max. Actual values OT
S K dimension mm 3.3 3.2 3.4
S KF dimension mm 5.8 5.7 5.9
S MS dimension mm 2.5 2.4 2.6
S Control lever angle alpha deg. 25 21 29
S Control lever angle beta deg. 24 19 29
About
S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)