Model XTS 900-12 XTS 1200-24 XTS 1400-48 XTM 1500-12 XTM 2000-12 XTM 2400-24 XTM 2600-48 XTM 3500-24 XTM 4000-48 XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH 8000-48
Inverter
Nominal battery voltage 12Vdc 24Vdc 48Vdc 12Vdc 24Vdc 4 8 Vd c 24Vdc 48Vdc 12Vdc 24Vdc 48Vdc
Input voltage range 9.5 - 17Vdc 19 - 34Vdc 38 - 68Vdc 9.5 - 17Vdc 19 - 34Vdc 38 - 68Vdc 19 - 34Vdc 38 - 68Vdc 9.5 - 17Vdc 19 - 34Vdc 38 - 68Vdc
Continuous power @ 25°C 650**/500VA 800**/650VA 900**/750VA 1500VA 2000VA 2000VA 2000VA 3000VA 3500VA 2500VA 4500VA 5000VA 7000VA
Power 30 min. @ 25°C 900**/700VA 1200**/1000VA 1400**/1200VA 1500VA 2000VA 2400VA 2600VA 3500VA 4000VA 3000VA 5000VA 6000VA 8000VA
Power 5 sec. @ 25°C 2.3kVA 2.5kVA 2.8kVA 3.4kVA 4.8kVA 6kVA 6.5kVA 9kVA 10.5kVA 7.5kVA 12kVA 15kVA 21kVA
Maximum load Up to short-circuit
Maximum asymmetric load Up to Pcont.
Load detection (stand-by) * 2 to 25 W
Cos 0.1-1
Consumption OFF/Stand-by/ON 1.1W/1.4W/7W 1.2W/1.5W/8W 1.3W/1.6W/8W 1.2W/1.4W/8W 1.2W/1.4W/10W 1.4W/1.6W/9W 1.8W/2W/10W 1.4W/1.6W/12W 1.8W/2.1W/14W 1.2W/1.4W/14W 1.4W/1.8W/18W 1.8W/2.2W/22W 1.8W/2.4W/30W
Output voltage * Pure sine wave 230Vac (±2%) / 120Vac (1)
Output frequency * 45Hz - 60Hz (1) ± 0.05% (crystal controlled)
Harmonic distortion <2%
Overload and short-circuit protection Automatic disconnection with 3 time restart attempt
Overheat protection Warning before shut-off - with automatic restart
Battery charger
Charge Characteristic *
Number of steps, thresholds, end current and times completely adjustable with the RCC-02/-03
Maximum charging current * 35A 25A 12A 70A 100A 55A 30A 90A 50A 160A 140A 100A 120A
Temperature compensation * With BTS-01 or BSP 500/1200
Power Factor Correction (PFC) EN 61000-3-2
General data XTS 900-12 XTS 1200-24 XTS 1400-48 XTM 1500-12 XTM 2000-12 XTM 2400-24 XTM 2600-48 XTM 3500-24 XTM 4000-48 XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH 8000-48
Input voltage range * 150 to 265Vac / 50 to 140Vac (1)
Input frequency 45 to 65Hz
Input current max. (transfer relay) /
16Aac/20Aac 50Aac/56Aac 50Aac/80Aac
Output current max.
Transfer time <15ms
Multifunction contacts Module ARM-02 with 2 contacts, in option 2 independent contacts (potential free 3 points, 16Aac/5Adc)
Weight 8.2 kg 9 kg 9.3 kg 15 kg 18.5 kg 16.2 kg 21.2 kg 22.9 kg 34 kg 40 kg 42 kg 46 kg
Dimension hxwxl [mm] 110x210x310 133x322x466 230x300x500
Protection index IP54 IP20
Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2
Conformity
Low voltage directive 2006/95/EC : EN 62040-1-1, EN 50091-2, EN 60950-1
Operating temperature range -20 to 55°C
Relative humidity in operation 100% 95% without condensation
Ventilation Optional cooling module ECF-01 Forced from 55°C
Acoustic level <40dB / <45dB (without/with ventilation)
Warranty 5 years
Accessoires
Remote control RCC-02 or RCC-03 • • • • • • • • • • • • •
Module XCOM-232i • • • • • • • • • • • • •
Internet based communication sets
• • • • • • • • • • • • •
Xcom-LAN, Xcom-GSM
Remote Control Module RCM-10 (3 m) • • • • • • • • •
2 aux. contacts module ARM-02 • • •
Cooling Module ECF-01 • • •
v 1.2.0
Battery temp. sensor BTS-01 (3 m) • • • • • • • • • • • • •
Communication cable for 3ph and //
• • • • • • • • • • • • •
CAB-RJ45-8-2
Mounting frame X-Connect • • • •
(1)
* Adjustable with the RCC-02/-03 ** These features are valid only when using the cooling module ECF-01. With -01 at the end of the reference, means 120V/60Hz. Available for all Xtenders except XTH 8000-48 Data may change without any notice.