Sulzer Pumps
Sulzer Pumps has a long history Sulzer Pumps offers products for Providing technical expertise in a
of providing innovative pumping all types of power plants-nuclear broad spectrum of pumping ap-
solutions to business partners in reactor, fossil fired, geothermal, plications benefits our customers.
the following industries: combined cycle, large and small Engineering and implementing
• Oil & Gas industrial power plants. reliable, cost effective pumping so-
• Hydrocarbon Processing We offer boiler feed pumps for lutions to meet the demands of a
• Pulp & Paper subcritical and supercritical fossil continually evolving power genera-
• Power Generation fuel plants, cooling water pumps, tion industry is our focus.
• Food, Metals & Fertilizers condensate extraction pumps and
• Water & Wastewater pumps for auxiliary services. We have a successful track record
of improving our customers’ profit-
ability by setting new standards in
efficiency in reliability. Millions of
people around the world are
benefiting from a more reliable
power supply as a result.
Design
Proven Technology
Shaft Seal
Single or double mechanical seal may
be installed. Cooled or uncooled design
according to specifications available.
Seal Housing
Can be cooled or uncooled
design; easy access to cool-
ing chamber; clearly arranged
connections; intensive, uniform
cooling.
Radial Bearing
Oil lubricated antifriction bearing
is standard; sleeve bearing also
available.
Shaft
Critical speed is higher than operat-
ing speed; small shaft deflection.
Areas subject to wear are protected.
Running speeds up to 4,000 rpm.
Impeller
In case of low NPSH available,
first stage double suction impel-
ler can be provided for selected
pump sizes.
Wear Rings
Maintain high efficiency during
pump life. Low maintenance cost,
high availability and short down
times. Impeller wear rings are
optional.
NDE Bearing Arrangement with Balance Drum
The balance drum device carries the major propor-
tion of the hydraulic thrust. The drum diameters are
chosen to minimize the thrust at normal operating
point. The residual and additional thrust loads occur-
ring above/below at the normal operating point are
carried by the thrust bearing, typically a taper roller
bearing.
MC 50 Hz
MC 60 Hz
Operating Data
MC 50 Hz MC 60 Hz
Pump sizes 40 to 200 mm 1.5 to 8 inches
Capacities 20 to 800 m /h
3
80 to 4,000 USgpm
Heads up to 1,600 m up to 5,500 feet
Pressures up to 180 bar up to 2,600 psi
Temperatures up to 180° C up to 355° F
Check our worldwide offices at
www.sulzerpumps.com
E-mail power.pumps@sulzer.com