Aluflam Fire-Rated Aluminum Full Vision Doors and Frames - 3-Part Specification
Aluflam Fire-Rated Aluminum Full Vision Doors and Frames - 3-Part Specification
Aluflam Fire-Rated Aluminum Full Vision Doors and Frames - 3-Part Specification
Notes to Specifier:
Section numbers are from MasterFormat 1995 Edition, with numbers from MasterFormat 2004
Edition in parentheses. Delete the version that is not required.
Notes to the specifier are contained in boxes and should be deleted from final copy. Optional
items requiring selection by the specifier are enclosed within brackets and highlighted in yellow.
Make appropriate selections and delete others.
When editing is complete, delete all text on this page, then remove the section break at the top
of the next page to remove this page from the document.
PART 1 - GENERAL
A. Fire-rated aluminum full vision Aluflam door system including pre-finished door, frame, glazing,
and hardware.
1.3 REFERENCES
A. Performance Requirements:
Project Name/Number/Date 08120 (08 11 16) - 1 Fire-Rated Aluminum Doors and Frames
Notes to Specifier: Select fire rating to meet building code requirements.
1. Fire Rating: [20] [45] [60] [90] minutes.
2. Certification: Doors and frames shall be tested in accordance with ASTM E 2074, NFPA
252, UBC 7-2, UL 10C, CAN4-S104.
3. Testing Laboratory: Fire tests shall be conducted by an approved independent testing
laboratory, similar to Underwriter’s Laboratories, Inc.
1.05 SUBMITTALS
A. Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal
Procedure Section.
1. Shop Drawings: Submit shop drawings showing layouts, profiles and product components.
2. Samples: Submit samples for finishes, colors and textures.
3. Technical Information: Submit latest edition of manufacturer’s product data providing
product description, technical data and installation instructions.
A. Ordering: Comply with manufacturer’s ordering instructions and lead-time requirements to avoid
construction delays.
C. Storage and Protection: Store off ground, under cover, protected from weather, direct sunlight,
construction activities and at temperature conditions recommended by manufacturer, +10°F to
+110°F.
D. Handling: Protect materials and finish during handling and installation to prevent damage.
A. Field Measurements: Verify actual measurements for openings by field measurements before
fabrication. Show recorded measurements on shop drawings. Coordinate field measurements and
fabrication schedule with construction progress to avoid construction delays.
PART 2 - PRODUCTS
Project Name/Number/Date 08120 (08 11 16) - 2 Fire-Rated Aluminum Doors and Frames
1. Contact: 16604 Edwards Road, Cerritos, CA 90703: Telephone 562.926.9520 Fax
562.404.1394. E-mail info@aluflam-usa.com Website www.aluflam-usa.com, or local
representative (www.aluflam-usa.com/contact/representatives.php).
A. Frame construction: Integral structure and glazing stops from extruded and
thermally broken aluminum profiles. Filled internally with cement composite material.
B. Dimensions:
1. Door framing face dimension: 2-½ inch
2. Depth of door framing: 3-7/16 inch (3-5/8 for 90 Min Door)
3. Door stile face dimension: 3-9/16 inch (3-3/4 for (90 Min Door)
4. Door cross rail (if applicable): 3-9/16 inch (N/A for 90 Min Door)
D. Sealing: Framing system shall insulate against effects of fire, smoke, and heat
transfer from either side. Perimeter of the framing system to the rough opening shall be firmly
packed with mineral wool insulation.
A. Fasteners: All fasteners, setting pads, and glazing clips, shall be stainless or zinc-plated steel.
B. Glazing Accessories: The glazing material perimeter shall be separated from the perimeter
framing system with approved flame retardant intumescent glazing tape. Ceramic setting blocks
shall be placed between the metal setting pads and the glazing material. Setting pads and blocks
provided by manufacturer.
Project Name/Number/Date 08120 (08 11 16) - 3 Fire-Rated Aluminum Doors and Frames
2.05 FABRICATION
A. Door frames and door leaves shall be furnished pre-assembled. Door assemblies shall be field
glazed.
2.06 FINISHES
A. Framing shall be chemically cleaned and pretreated, then finished on all exposed areas with:
Notes to Specifier: Select finish and color.
[Anodized – Clear] [Anodized – Light Bronze] [Anodized – Medium Bronze] [Anodized – Dark
Bronze] [Powder Coated Epoxy – Color RAL#XXXX] [Fluropolymer Paint – Kynar/Duranar UC
Code XXXXX].
B. Protect finishes on exposed surfaces from damage by applying a strippable, temporary protective
covering before shipping.
Notes to Specifier: Select hardware schedule(s) based on door configuration. Consult with
Aluflam prior to specifying alternative hardware or hardware finishes. Hardware denoted with *)
is optional.
[B. Operating hardware for single doors. Each to have the following:
Quantity Description Manufacturer/Model Finish
1 Surface applied door closer Dorma TS93 series Aluminum
3 Surface applied hinges (Qty 4 Dr Hahn A901/951 series Aluminum
on 90 min door)
2 Lever handles FSB 1080 series Stainless
1 Narrow stile mortise lock Accurate 8600 series Stainless (front)
1 Cylinder lock Schlage compatible Satin chrome
1 *) Rim based exit device – Dorma 9700 Stainless
(Standard on 90 min door)
1 *) 10” bottom kickplate Aluflam Match door finish
1 *) Automatic floor seal Planet MF Aluminum
Project Name/Number/Date 08120 (08 11 16) - 4 Fire-Rated Aluminum Doors and Frames
Balance of hardware by others]
[C. Operating hardware for active/inactive pairs of doors (Not available in 90 Min rating. Each to have
the following:
Quantity Description Manufacturer/Model Finish
1 Surface applied door Dorma TS93-1GSR Aluminum
closer/coordinator series
6 Surface applied hinges Dr Hahn A901 series Aluminum
2 Lever handles FSB 1080 series Stainless
1 Narrow stile mortise lock Accurate 8600 series Stainless (front)
1 Automatic flush bolt BKS B1899/1895 Stainless
1 Cylinder lock Schlage compatible Satin chrome
1 Thumbturn FSB 1709 series Stainless
1 *) Rim based exit device Dorma 9700 Stainless
2 *) 10” bottom kickplate Aluflam Match door finish
2 *) Automatic floor seal Planet MF Aluminum
Balance of hardware by others]
[D. Operating hardware for active/active pairs of doors. Each to have the following:
Quantity Description Manufacturer/Model Finish
2 Surface applied door closers Dorma TS93 series Aluminum
6 Surface applied hinges (Qty 8 Dr Hahn A901/951 Aluminum
for 90 Min Doors) series
2 Vertical rod exit devices (top rod Dorma 9800 series Stainless
only for 60 min and lower rated,
90 min - top & bottom rods)
2 *) 10” bottom kickplate Aluflam Match door finish
2 *) Automatic floor seal Planet MF Aluminum
Balance of hardware by others]
PART 3 - EXECUTION
3.01 EXAMINATION
A. Examine area to receive doors. Openings shall be plumb, square and within allowable tolerances.
Notify Architect of conditions that would adversely affect installation or subsequent use. Do not
proceed with installation until unsatisfactory conditions are corrected.
3.02 INSTALLATION
A. Door installation shall be by a specialty contractor with appropriate experience qualifications; and
in strict accordance with the approved shop drawings.
3.03 CLEANING
A. Cleaning: Remove temporary coverings and protection of adjacent work areas. Glass and frame
should be cleaned using soft clean cloth, chamois leathers, sponges or soft paper. Use clean
Project Name/Number/Date 08120 (08 11 16) - 5 Fire-Rated Aluminum Doors and Frames
warm water with a mild detergent. Do not use detergent that contains either alkaline, acids or
fluoride! Abrasive cleaning methods can damage surfaces! Clean prior to owner’s acceptance.
Remove construction debris from project site and legally dispose of debris.
END OF SECTION
Project Name/Number/Date 08120 (08 11 16) - 6 Fire-Rated Aluminum Doors and Frames