GEAR-FLEX COUPLING
R-II-G-04/00-03/09
Amendments
Sr.No. Description Old NO. Rev. NO. Nature of change Effective Date
1
R-II-G-04/00-03/09
TABLE OF CONTENTS
R-II-G-04/00-03/09
GEAR - FLEX COUPLING INSTALLATION PROCEDURE
The performance and the life of the gear coupling depend on how you install and service
them.
1. Remove the coupling from packing & thoroughly inspect for signs of damage.
2. Disassemble the coupling by removing nuts & bolts. Clean all the parts carefully.
1. Slide the sleeves with internal teeth with rubber O ring on shafts before mounting the
hubs.
2. Mount the hubs with external teeth on their respective shafts flushed with the faces of
hubs as shown in Fig. 1.
Fig. 1
3. With one machine firmly bolted down, set the equipments at a distance ‘G’ (refer table A
& B) between shaft ends by using a spacer bar equal in thickness to the required gap ‘G’ as
shown in Fig. 2.
Fig. 2
Deviation in standard DBSE is defined as axial misalignment (end float). For normal
applications the shaft end should be flushed with inner face of the adapter. In some special
cases the shaft ends may protrude beyond the inner face of the adapter or may remain
inside, if required. The distance between two faces of adapter flanges is to be maintained
as specified. The variation in this distance should not exceed the permissible initial axial
misalignment given in table A.
R-II-G-04/00-03/09
(C) ALIGNMENT PROCEDURE:-
Alignment procedure is given separately for each type of alignment, for simplicity. However
all 3 types of misalignments may be present at the same time.
Fig. 3
(II) CHECKING ANGULAR ALIGNMENT:-
Check the angular misalignment with the
help of slip gauges by inserting in the gap
at 4 places 90° apart. The deviation in the
values of standard gap ‘G’ is Total
Indicated Reading (TIR). The angular
misalignment ‘X’ in mm is half the Total
Indicated Reading. The values of angular
misalignment should not exceed
permissible initial misalignments
mentioned in table A. (Refer Fig. 4).
Fig. 4
IMPORTANT: If the coupling is dynamically balanced, ensure that the match marks are in
straight line & unidirectional before bolting the assembly.
IMPORTANT: The necessity for shields & guards varies with individual installations. The
owner or user must provide the required safety guards. Safety guards or shields are not
furnished by us with these equipments.
R-II-G-04/00-03/09
TABLE ‘A’
TABLE ‘B’
PERMISSIBLE MAXIMUM MISALIGNMENTS FOR GEAR COUPLINGS
R-II-G-04/00-03/09
TABLE ‘C’
TABLE ‘D’
FLANGE BOLT
Sr. No. COUPLING SIZE
TORQUE (Nm)
1 10 28
2 15 28
3 20 97
4 25 132
5 30 132
6 35 244
7 40 244
8 45 244
9 50 477
10 55 477
11 60 477
12 70 576
R-II-G-04/00-03/09