Overview
ESA 4.4.8.249 has been released to production. This release includes support for P30-1011-134
CECU3 software, P30-1030-109 CECU3 software, and P30-1033-105 HVAC software. ICU and
CECU obsolescence support, Auto Start test updates, DLA support enhancements, and
Bayswater plant support are new features in this release.
Changes Implemented
New Features:
ICU and CECU obsolescence support
o ECAT files with an ICU or CECU baseline part number will not create a warning
message of 'Incorrect vehicle software' on connect
o ECAT files with an ICU or CECU baseline part number allow ESA to display the
appropriate baseline options within the flashing wizard for CECU3 units
o Programming of ECAT values from one baseline to another baseline that will
include default values that are not addressed by the ECAT file
o Programming of backup values from one baseline to another baseline that will
include default values that are not addressed by the backup file
o Set emulation parameter correctly based on origin of backup file or part number
in ECAT file
NEXIQ USB Link driver not detected warning message removed from ESA installation
wizard
NEXIQ USB Link 2 Wi-Fi DLA supported with a wired connection
o Wireless connectivity only supported with Bluetooth model
Auto Start test updates
o Backup alarm test included
o Displayed instructions updated for more clarity
o Updates included in P30-1011-129, P30-1011-130, and P30-1011-134 packages
P30-1032 emulator package added
Emulator packages updated to the latest software versions for NAMUX 2 and NAMUX 4
Electric over Air images updated for simulation function in P30-1030 software
o Old virtual images were replaced with images of Electric over Air gauge
Copyright dates updated in Help > About screen and during installation wizard
Able to download ECAT files for ICU units
Backup and restore functionality updated to reduce the number of failed attempts
Brake Vendor parameter description updated for P30-1011 software
o New parameter description: Brake System VDC1 SA
o New parameter values: 0x0B, 0x0E, Other
Bayswater added to plant locations within Internal tab of the Admin form
o New record added to ESA web service that will allow Bayswater to automatically
configure all ESA workstations at their location
P30-1011-134 NAMUX 4 CECU3 software supported
o Optional update
o New Features:
None
o Defect Fixes:
Pop-up message and audible sound suppressed during Auto Start
feature every time it goes back to standby state after checking the engine
oil temp and the engine does not need to start
Update the rate of cab controller unit sending J1939 Brakes message
from 50ms to 1000ms per message to prevent 2010 emission MX engine
logging active fault
P30-1030-109 NAMUX 2 CECU3 software supported
o Required update for all previous P30-1030 software versions
o New Features:
Dual Steer Safety Interlock added for Peterbilt Model 320
Operator must not be trying to simultaneously start the engine
and switch active sides of the cab.
Merged P30-1032-106 into P30-1030-109
P30-1030-XXX will still be used for Medium Duty models for both
divisions but will now also be used for the Peterbilt Model 320.
Variable Speed Coolant Pump for Peterbilt Model 320 w/MX-11
ICU/CECU Obsolescence Backwards Compatibility Updates for CECU3
MX Engine SOFT CI Message Display Update
This pertains to software version and chassis/truck information
shown to operator in menus.
Adjust MX Engine Overspeed Warning Thresholds
Surpassing 2000 RPM will no longer trigger a warning.
Timed Axle Temp Warning
Axle temperatures over 249.98F lasting over 1 hour will trigger
the same warning triggered immediately by axle temperatures
over 275F.
Support Brake Switch on V-CAN
Foot brake switch input into the CECU3 or foot brake analog
pressure input into the CECU3 will both be used to broadcast the
foot brake as being applied or not applied on V-CAN. Increases
reliability of foot brake status communication.
Remove Accelerator Pedal from Parked Condition
Holding increased engine speed with the accelerator pedal for 10
seconds while sitting still with park brake set will no longer trigger
a warning to the operator.
Ignore Accelerator when Park Brake is Active
Customer option (via ESA parameter) now available to disable
the accelerator while the park brake is active.
o Defect Fixes:
High Exhaust Temp warning invisible above 10 MPH
(no longer invisible)
Priority conflicts resolved for some warnings on Peterbilt trucks
Missing signal added to Vehicle Speed Limiter functionality
3-Position Engine Retarder Switch de-bounced in software
Prior to fix, switch was capable of causing the retarder to be
briefly inoperable.
Missing Spanish/French labels added for DEF Level and Diesel Fuel
Level virtual gauges on Model 320 Dual Steer configurations
P30-1033-105 HVAC software with limited support
o Ability to flash this software onto HVAC control units is not included
o ESA connections, diagnostics, and self-tests are available functions
o Low Charge Protection Calibrations – Unique values for four truck variants
KW Daycab and Sleeper
PB Daycab and Sleeper
o Functionality Updates
Added Semi-Automatic Mode Functionality
Defrost Mode revision
o DM1 message revision
o Shutdown Procedure reduced from 240 seconds to 100 seconds
o C-CAN Message update (Backward Compatible)
Blower Speed and Temperature Knob, currently message sends request
status
Updating to actual blower speed and temperature door position
Supports EPA 2017 operation with MX Engine Variable Speed Coolant
Pump
Defect fixes:
Overspeed Shutdown Low Air Threshold parameter programs successfully for P30-1030
software
NEXIQ USB Link 2, JPRO DLA+ 2.0, and JPRO DLA+Wireless 2.0 devices can read
mileage from 2016 engine control modules
Removed baud rate not found error message when connecting NEXIQ USB Link 2 to a
flashing station
Known Issues:
Restoring parameters to an ICU using an ECAT file with a Q21-1029 part number causes
ESA to crash
Replacing an ICU with a CECU3 and downloading an ECAT file with a Q21-1029 part
number will not limit the flashing options to P30-1030 as it should
JPRO DLA+ 2.0 and DLA+Wireless 2.0 will not detect PACCAR Display 1.0 on 2016
vehicles without the use of a crossover cable; not a significant concern since 2016
vehicles should not have PACCAR Display 1.0 devices installed
ESA occasionally will not read mileage on vehicles with 2016 MX engines
Update Instructions
1. Select Tools->Check for Updates
a. Follow prompts
2. Click Updates Available button
3. Download all software updates
4. Verify ESA is at version 4.4.8.249
Update Instructions
System pre-requisites:
1. Windows 7/8, Windows Vista
2. .NET 4.0 Full Framework version
3. Visual C++ runtimes
a. 2010
b. 2008
c. 2005 with ATL update
4. NEXIQ drivers 9.0 or greater
a. NEXIQ drivers 9.0.1.0 or greater required for Windows 8
5. PC with at least 600 MB free space
6. Internet access from the PC
7. Administrative Rights on the PC
8. ESA license key
9. An e-portal user account and password
Instructions:
For users with ESA already installed.
Please note if your system does not meet the pre-requisite requirements installation will fail.
1. You can download the latest build released by copying the following link into the address
bar of your web browser and clicking Go. (This process works better than using a link
from within this document).
http://paccar.httpsvc.vitalstreamcdn.com/paccar_vitalstream_com/Application/VpdSetup.zip