Ameron PN220G
Ameron PN220G
Ameron PN220G
Amercoat 220 G
Water borne acrylic finish
Product Data/
Application Instructions Physical Data
Appearance when dry ........... glossy
Single pack water borne acrylic finish Colour .................................... RAL and BS*
EPA compliant (1998)
Components ........................... 1
Low volatile organic compounds content
Low odour Volume solids ........................ 40 2%
Non-flammable
VOC**
Good colour and gloss retention EC SED 1999/13/EC ........... 41 g/kg (50 g/l)
Compatible with most aged coatings UK PG6/23(92) Appendix 3 . 140 g/l
Quick and easy to apply by brush, roller and Curing mechanism ................. physical drying
spray
typical minimum maximum
Surface Preparation
Applied over surfaces primed with suitable primer. Application Data
The priming system and preparation will depend on Substrate ................................ primed substrates
the type and condition of the substrates. Consult your
PPG representative for detailed specifications. Application methods ............... airless spray, brush, roller
All surfaces must be dry and free of dust, salts, Potlife (at 20C/68F) ............ not applicable
grease and other contaminants immediately before
coating. Environmental Conditions
NOTE: drying and curing times are dependent on air and substrate
temperature, applied film thickness, ventilation and other
environmental conditions. Times are shorter at higher temperatures
and longer at lower temperatures
Application procedure
1. Flush equipment with recommended cleaner Shipping Data
before use. Pack size ...................... 5 litres
2. Stir the contents of the can to an even
consistency. Shipping weight ............ approx. 7 kg
3. Thinning is normally not required for airless spray.
4. Stir during application to maintain uniformity of Shelf life ....................... 1 year from shipment date
material. When spraying, apply a wet even coat in or as indicated on label when
parallel passes. Overlap each pass 50% to avoid stored indoors in unopened,
bare areas, pinholes or holidays. original containers at 5 to
5. Double coat all rough spots, sharp edges and 40C (41 to 104F)
corners, rivets, bolts, etc.
6. Application at 100 m wet film thickness will
normally provide 40 m dry film.
7. Check thickness of dry coating with a non-
destructive dry film thickness gauge, such as
Mikrotest or Elcometer. If less than specified
thickness, apply additional material as needed.
8. Small damaged or bare areas and random
pinholes or holidays can be touched up by brush.
Repair larger areas by spray.
9. In confined areas ventilate with clean air during
application and drying until all solvents are
removed. Temperature and humidity of ventilating
air must be such that moisture condensation will
not form on surface.
10.Clean all equipment with recommended cleaner
immediately after use or at least at the end of each
working day or shift
Condition of Sale
All our transactions are subject to our Terms and
Conditions of Sale.
www.ppgpmc.com