BR 21443 Chromatography Catalog LC BR21443 en
BR 21443 Chromatography Catalog LC BR21443 en
BR 21443 Chromatography Catalog LC BR21443 en
1.5
1.0
Chromatography Columns
0.5
and Consumables 2016-2017
Connected chromatography
solutions
LC Columns and Accessories
As a leader in LC column technology including silica, polymer and porous graphitic
carbon manufacturing, bonded phase production and column packing for 40 years,
you can rely on the quality of Thermo Scientific HPLC products. Here, we showcase
our latest and most comprehensive range of innovative columns, accessories and
equipment for fast LC, analytical HPLC and UHPLC.
Featured Products
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4
LC Columns and Accessories >>
Section Contents
Accucore HPLC and UHPLC Columns . . . . . . . . . . 4-005 Syncronis HPLC and UHPLC Columns . . . . . . . . . . 4-062
Hypersil GOLD HPLC and UHPLC Columns . . . . . . 4-020 Hypersil BDS and Hypersil Classical HPLC Columns 4-070
Acclaim HPLC and UHPLC Columns . . . . . . . . . . . 4-034 LC Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-078
Section Contents
Application Specific HPLC Columns . . . . . . . . . . . 4-048 LC Reagents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-098
Hypercarb HPLC Columns . . . . . . . . . . . . . . . . . . . 4-059 LC and LC-MS Instruments . . . . . . . . . . . . . . . . . . 4-108
Acclaim Viper
Acclaim columns are based on Maximize liquid chromatography
high-purity, porous silica particles (LC) performance and get zero-
with advanced and innovative dead-volume connections to
column bonding technologies. This ensure optimal separations.
provides complementary selectivity, PAGE 4-078
high column efficiencies and
symmetrical peaks.
PAGE 4-034
www.thermoscientific.com/chromatography 4-001
Thermo Scientific Chromatography Columns and Consumables 2016-2017
LC Columns and Accessories
4-002
LC Columns
Technical Resources
visit www.thermoscientific.com/chromexpert
Technical Resources
Chromophore Detection Wavelengths
Column Cleaning and Regeneration
www.
thermoscientific.com/chromexpert
www.
thermoscientific.com
/chromexpert
www.
thermoscientific.com
/chromexpert
www.thermoscientific.com/chromatography 4-003
Columns for Fast
LC Columns and Accessories
The Thermo Scientific LC column portfolio offers a comprehensive range of high quality
options for fast and analytical HPLC and UHPLC.
The table below shows our leading column families with details of relative hydrophobicity, key attributes and how the attributes
are achieved. Use this table and the information in the subsequent catalogue pages to find the best Thermo Scientific LC columns
for your separation needs.
Accucore Columns
Page 4-005 1.5, 2.6 and 4m solid
Ultimate core silica particles
Performance C ore Enhanced
Technology
Low
Hypersil GOLD Columns
Page 4-020 1.9, 3, 5 and 12m
ultra-high purity silica
Selectivity & particles
Peak Shape
W ide range of
conventional phases
Acclaim Columns
Page 4-034 2.2, 3 and 5m ultra-pure
Traditional,
Speciality & silica particles
Medium/High
Application Innovative and unique
Specific Phases bonded phases
Hypercarb Columns
Page 4-059 3 and 5m 100% porous
Extended graphitic carbon particles
Very High Separation
Polar retention effect
Capabilities
on graphite (PREG)
4-004
LC Columns and Accessories >>
Accucore HPLC
and UHPLC Columns
Accucore
Speed and Selectivity Combined
Thermo Scientific Accucore HPLC and UHPLC columns are a family of high speed,
high resolution columns based on Core Enhanced Technology.
Next-Generation Accucore
Vanquish UHPLC Columns
Combines the benefits of a solid core material
and the increased chromatographic efficiency of
a sub-2m particle
www.thermoscientific.com/chromatography 4-005
Accucore Vanquish
LC Columns and Accessories
Better separations
The high efficiency offered by Accucore Vanquish UHPLC columns enables the
resolution of very complex mixtures.
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Minutes
4-006
More results
20
Accucore Vanquish 1.5m
Accucore Vanquish C18,1.5m
18
Solid core 1.7m
Solid Core C18 1.7m
16
Solid core 1.6m
Solid Core C18 1.6m
14 Mobile Phase: Water:acetonitrile (50:50)
12 Temperature: 30C
Flow Rate: 0.1 to 0.6mL/min
H (m)
10
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0
(mm/s)
Reproducibility
The advanced bonding and automated packing technology used in the manufacture of Accucore
Vanquish UHPLC columns results in exceptionally reproducible chromatography.
Accucore
4.5
Accucore Vanquish C18 1.5m
4.0
Mobile Phase: Acetonitrile:20 mM ammonium formate
3.5
Capacity Factor ('k)
pH 3.0 (50:50)
3.0 Temperature: 30C
2.5 Flow Rate: 0.4mL/min
2.0
1.5
1.0
0.5
0.0
0 500 1000 1500 2000 2500 3000 3500 4000
Injection Number
Easier interaction
Accucore Vanquish UHPLC columns, the Vanquish UHPLC System and the Thermo Scientific Dionex
Chromeleon Chromatography Data System are combined into a seamless workflow solution, which
allows for simple and easy to implement separations.
Accucore Vanquish
Particle Size (m) Format Length (mm) ID (mm) C18+
1.5 UHPLC Column 50 2.1 27101-052130
100 2.1 27101-102130
150 2.1 27101-152130
www.thermoscientific.com/chromatography 4-007
Accucore RP-MS pH Range
LC Columns and Accessories
Accucore RP-MS uses an optimized alkyl chain length for more effective coverage of 0 80 300
the silica surface. This coverage results in a significant reduction in non-hydrophobic Carbon Load (%)
interactions and thus highly efficient peaks with very low tailing.
0 7 25
RP-MS offers slightly lower retention than C18 and this combined with high efficiencies
Particle Size 2.6m
and low peak tailing make this the phase of choice for use with MS detection.
The selectivity offered by Accucore RP-MS matches that of C18 columns.
Bases
240 Accucore RP-MS 2.6m, 50mm x 2.1mm
4
Mobile Phase: 65% Methanol / 35% 25mM
Potassium Phosphate pH7.0
200 2 Temperature: 30C
Flow Rate: 500L/min
Injection Volume: 1L
160 Backpressure: 232 bar
Detection: UV, 215nm
Analytes: 1. Uracil
1 2. Propranolol
120
mAU
3. Butylparaben
4. Naphthalene
3
5 5. Acenaphthene
80
6 6. Amitriptyline
40
Tf = 1.27
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Minutes
Accucore RP-MS
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17626-012105 17626-013005 17626-014005
HPLC Column 30 17626-032130 - -
50 17626-052130 17626-053030 17626-054630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-008
Accucore C18 pH Range
The carbon loading of Accucore C18 phase provides high retention of non-polar 0 80 300
The highly retentive nature of Accucore C18 phase means that it can be used 0 9 25
to separate a broad range of analytes.
Particle Size 2.6m USP L1
Triazines
Accucore C18 2.6m, 50mm x 2.1mm
100 Mobile Phase A: Water
Mobile Phase B: Acetonitrile
3
Gradient: Time (min) %B
80 1.0 35
2 2.5 70
4 Temperature: 25C
6
60 Flow Rate: 600L/min
mAU
1 Injection Volume: 2L
Backpressure: 298 bar
Detection: UV, 280nm
40
Accucore
5 Analytes: 1. Simazine
2. Simetryn
3. Atrazine
20 4. Ametryn
5. Propazine
6. Prometryn
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Minutes
Accucore C18
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17126-012105 17126-013005 17126-014005
HPLC Column 30 17126-032130 - -
50 17126-052130 17126-053030 17126-054630
100 17126-102130 17126-103030 17126-104630
150 17126-152130 17126-153030 17126-154630
4 Drop-in Guard (4/pk) 10 74104-012101 74104-013001 74104-014001
HPLC Column 50 74104-052130 74104-053030 74104-054630
100 74104-102130 74104-103030 74104-104630
150 74104-152130 74104-153030 74104-154630
250 74104-252130 74104-253030 74104-254630
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-009
pH Range
2 to 9 14
Accucore C8
0
LC Columns and Accessories
pH Range
Hydrophobicity
Accucore C8 HPLC columns offer lower hydrophobic retention than columns packed Carbon Load (%)
0 5 25
with longer alkyl chain length material, such as C18, and are therefore
Particlefor
recommended Size 2.6m with medium hydrophobicity or USP
analytes whenL7a less hydrophobic
0 5 25
Relative Abundance
70 Gradient: 5951500L/min
% B in 0.8 minutes
Relative Abundance
Accucore C8
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17226-012105 17226-013005 17226-014005
HPLC Column 30 17226-032130 - -
50 17226-052130 17226-053030 17226-054630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-010
Accucore aQ pH Range
The polar functional group used to endcap Accucore aQ phase provides an 0 80 300
additional controlled interaction mechanism by which polar compounds can be Carbon Load (%)
retained and resolved, making the Accucore aQ phase ideal for the quantitative
0 9 25
analysis of trace levels of polar analytes.
Particle Size 2.6m USP L1
The wettability of reversed phase media can be increased by the introduction of
polar functional groups. The polar endcapping of Accucore aQ media also makes it
usable in 100% aqueous mobile phases without the risk of loss of performance or
poor stability.
Lamivudine (USP)
Accucore
Temperature: 35C
ent: 100
595 % B in 0.8 minutes Flow Rate: 200L/min
mAU
Accucore aQ
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17326-012105 17326-013005 17326-014005
HPLC Column 30 17326-032130 - -
50 17326-052130 17326-053030 17326-054630
100 17326-102130 17326-103030 17326-104630
150 17326-152130 17326-153030 17326-154630
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-011
0 150 300
Carbon Load (%)
0 8 25
0 150 300
Accucore Polar Premium is an exceptionally rugged polar embedded reverse phase Carbon Load (%)
material that offers high efficiency, wider operating pH range and unique selectivity
0 8 25
complementary to standard C18 phases.
Particle Size 2.6m USP L60
The specially designed bonded phase is stable from pH 1.5 to 10.5 and will not
undergo phase collapse in 100% aqueous mobile phase.
Curcuminoids (Tumeric)
600
ccucore Polar Premium 2.6m, 100 x 3.0mm
A
1, 2, 3
1,2,3 Fused Core C18, 100 x 3.0mm
Mobile Phase: Methanol : 10mM Phosphoric Acid, 80 : 20
500
Temperature: 40C
Flow Rate: 800L/min
Injection Volume: 6L
400 Detection: UV, 428nm
Fused core C18
Analytes: 1. Curcumin
2. Desmethoxycurcumin
300 Fused Core C18
3. Bis-desmethoxycurcumin
mAU
200
1 The Accucore Polar Premium HPLC column provides desirable
selectivity that resolves the major and minor component
100
2 Accucore Polar Premium under simple isocratic conditions
600
in less than three minutes,
3 1, 2, 3
while the C18 columns fail to separate these components.
1,2,3
500
-50
0.00 1.00 2.00 3.00
400
Minutes Fused core C18
200
1
Accucore Polar Premium
Particle Size (m) Format Length (mm) 2.1mm ID 100
3.0mm ID 4.6mm ID Accucore Polar Premium
2
3
2.6 Defender Guard (4/pk) 10 28026-012105 - -
Thermo Scientific Chromatography Columns and Consumables 2016-2017
Minutes
150 28026-152130 28026-153030 28026-154630
250 28026-252130 - -
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
4-012
Accucore Phenyl-Hexyl pH Range
and selectivity, while the phenyl ring can add special selectivity by interacting Carbon Load (%)
with polar groups within the solutes. This results in a mixed-mode separation
0 5 25
mechanism. The reduced hydrophobicity of this phase makes it ideal for the
separation of very non-polar compounds. Particle Size 2.6m USP L11
The Phenyl-Hexyl phase should be selected for complex samples where some peaks
are well resolved on a conventional alkyl phases, but are not well resolved on a
conventional phenyl phase, or when other peaks are well resolved on a phenyl
phase, but not well resolved on a conventional alkyl phase.
Beta-agonists
Accucore Phenyl-Hexyl 2.6m, 100mm x 2.1mm
100 2.89 NL: 9.22E5
m/z = 225.60-226.60 Mobile Phase A: Ammonium Acetate 5mM, pH 4
Accucore
Mobile Phase B: Acetonitrile
Terbutaline
0 Gradient: Time (min) %B
100 3.04 NL: 6.51E5 0 5
m/z = 239.60-240.60 MS 1 5
10 100
Cimaterol Temperature: 40C
0
100 NL: 3.52E6 3.16 Flow Rate: 0.25mL/min
m/z = 219.60-220.60 Injection Volume: 1L
Backpressure: 120 bar (at t0)
Salbutamol
0 Detection: +ESI-MS (45C, 4.5kV, 60V,
100 NL: 2.23E6 4.72 scan 150 350)
m/z = 301.60-302.60 MS
Ractopamine
0
100 NL: 2.51E6 4.80
m/z = 213.60-214.60 MS
Clorprenaline
0
100 NL: 1.71E6 5.13
m/z = 276.60-277.60 MS
Clenbuterol
0
0 1 2 3 4 5 6 7
Minutes
Accucore Phenyl-Hexyl
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17926-012105 17926-013005 17926-014005
HPLC Column 30 17926-032130 - -
50 17926-052130 17926-053030 17926-054630
100 17926-102130 17926-103030 17926-104630
150 17926-152130 17926-153030 17926-154630
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-013
0 80 300
Carbon Load (%)
0 6 25
0 80 300
The proprietary Accucore Phenyl-X alkyl aromatic bonded phase provides a unique Carbon Load (%)
selectivity when compared to other reversed phase materials such as C18 or Phenyl.
0 6 25
The advanced design of the bonded phase makes it compatible with highly aqueous
Particle Size 2.6m
mobile phases and robust, demonstrating very low bleed.
Phenyl-X exhibits particularly high aromatic selectivity.
Estrogens
1
120
ccucore Phenyl-X 2.6m, 100 x 2.1mm
A
Fused Core C18, 100 x 2.1mm
100
Mobile Phase: 15:40:45 (v/v) Acetonitrile:Methanol:Water
2 4 Temperature: 40C
80
3
Flow Rate: 400L/min
mAU
60
Injection Volume: 1L
40 Detection: UV, 220nm
20
Fused Core C18
0
0.0 0.5 1.0 2.5 2.0 2.5 3.0 3.5 4.0 5.5 6.0 1. Estriol (E3) 2. Estradiol (E2)
Minutes
OH OH
150 H3C H3 C
1 OH
H
H
125
H H
H H
100 HO
HO
2 3 2.04 1
mAU
75
4 120
3. Estrone (E1) 4. Ethynylestradiol
50 100
OH OH
H3C H3C 2
25 80 CH 4
H H 3
mAU
0 60
H H H H
HO HO 40
0.0 0.5 1.0 2.5 2.0 2.5 3.0 3.5 4.0 5.5 6.0
Minutes 20
Fused Core C18
0
0.0 0.5 1.0 2.5 2.0 2.5 3.0 3.5 4.0 5.5 6.0 1. Estriol (E3)
Minutes
150 1
Accucore Phenyl-X
Thermo Scientific Chromatography Columns and Consumables 2016-2017
125
H
Particle Size (m) Format Length (mm) 2.1mm ID 100 3.0mm ID 4.6mm ID HO
4
3. Estrone (E1
HPLC Column 50 27926-05213050 27926-053030 27926-054630
100 27926-10213025 27926-103030 27926-104630
150 27926-1521300 27926-153030 27926-154630
HO
250 27926-252130 0.0 0.5
- 1.0 2.5 2.0 2.5
- 3.0 3.5 4.0 5.5 6.0
Minutes
4-014
Accucore PFP pH Range
The introduction of fluorine groups into the Accucore PFP (pentafluorophenyl) 0 80 300
stationary phase causes significant changes in solute-stationary phase interactions. Carbon Load (%)
This can lead to extra retention and selectivity for positional isomers of
0 5 25
halogenated compounds.
Particle Size 2.6m USP L43
PFP Columns are also well suited to the selective analysis of non-halogenated
compounds, in particular polar compounds containing hydroxyl, carboxyl, nitro,
or other polar groups. High selectivity is often most apparent when the functional
groups are located on an aromatic or other rigid ring system.
Positional isomers
50 Accucore PFP 2.6m, 50mm x 2.1mm
5 Mobile Phase A: 0.1% Formic Acid in Water
Mobile Phase B: 0.1% Formic Acid in Acetonitrile
40 Gradient: 15-30%B in 7 minutes
Temperature: 50C
Accucore
7 Flow Rate: 600L/min
Injection Volume: 2L
30 1 Detection: UV, 270nm
89 Analytes: 1. 3,4 Dimethoxyphenol
10 2. 2,6 Dimethoxyphenol
mAU
20 2 3. 2,6 Difluorophenol
12
11 4. 3,5 Dimethoxyphenol
13 14 5. 2,4 Difluorophenol
10 34 6 6. 2,3 Difluorophenol
7. 3,4 Difluorophenol
8. 3,5 Dimethylphenol
9. 2,6 Dimethylphenol
0 10. 2,6 Dichlorophenol
11. 4 Chloro-3-Methylphenol
12. 4 Chloro-2-Methylphenol
0 1 2 3 4 5 6 7 8 13. 3,4 Dichlorophenol
Minutes 14. 3,5 Dichlorophenol
Accucore PFP
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17426-012105 17426-013005 17426-014005
HPLC Column 30 17426-032130 - -
50 17426-052130 17426-053030 17426-054630
100 17426-102130 17426-103030 17426-104630
150 17426-152130 17426-153030 17426-154630
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-015
0 150 300
Carbon Load (%)
0 5 25
Accucore C30
Particle Size 2.6m USP L62
LC Columns and Accessories
pH Range
Accucore C30 offers high shape selectivity for hydrophobic, long chain, structurally 0 150 300
related isomers, for example carotenoids and steroids. This is a different Carbon Load (%)
form of shape selectivity from that measured in the steric selectivity phase
characterisation test. 0 5 25
Vitamin K isomers
100 1
50 2
2
0 250
Accucore C30 1
Minutes
150
Chromatogram showing the separation of Vitamin K compounds Fused Core C18
Minutes 1-Vitamin K2, 2-Vitamin K1 (trans isomer), 2-Vitamin K1 (cis isomer)
mAU
100 1
Accucore C30 50 2
28
4-016
Accucore HILIC pH Range
Catecholamines
Accucore
120 Flow Rate: 2mL/min
Injection Volume: 5L
1
4 Backpressure: 157 bar
100
Detection: UV, 280nm
Analytes: 1. Catechol
80 2. 5-HIAA
mAU
3
3. DOPAC
60 4. Serotonin
5. L-tyrosine
6. Dopamine
40 7. L-DOPA
5
6
20 7
0
0 0.5 1 1.5 2 2.5 3 3.5 4
Minutes
Accucore HILIC
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 17526-012105 17526-013005 17526-014005
HPLC Column 30 17526-032130 - -
50 17526-052130 17526-053030 17526-054630
100 17526-102130 17526-103030 17526-104630
150 17526-152130 17526-153030 17526-154630
UNIGUARD Drop-in 10 852-00 852-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-017
Low High
Pore Size
0 80 300
Carbon Loading
Accucore Urea-HILIC pH Range
LC Columns and Accessories
Bonded hydrophilic
Particle Size 2.6m stationary phase 0 2 to 8 14
Hydrophobicity
Unique selectivity compared to other HILIC phases
Low ion exchange activity Low High
Pore Size
Accucore Urea-HILIC has an alternative selectivity and lower ion exchange activity 0 80 300
than other HILIC phases.
Particle Size 2.6m
The bonded hydrophilic stationary phase provides retention of a broad range of
polar analytes using up to 20% aqueous mobile phase.
Analgesic compounds
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1. Acetaminophen 2.600
Salicylic acid 3. Aspirin
2
Minutes tR As tR As Rs tR As Rs
Mean 0.760 1.474 0.908 1.303 2.359 1.100 1.318 3.264
1
CV % 0.00 1.17 0.48 400 0.92 0.49 0.00 0.63 0.48
0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
Accucore Urea-HILIC Minutes
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.6 Defender Guard (4/pk) 10 27726-012105 - -
HPLC Column 50 27726-052130 27726-053030 27726-054630
100 27726-102130 27726-103030 27726-104630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-018
Accucore XL C18
Pore Size
The carbon loading of Accucore XL C18 provides high retention of non-polar 0 80 300
analytes via a predominantly hydrophobic interaction mechanism. Carbon Load (%)
0 7 25
30 Accucore XL C18
Accucore XL C18 4m, 150 x 4.6mm
25 2 Fully Porous C18 Fully porous C18 5m, 150 x 4.6mm
N = 18274 plates
20 1 S/N = 1202 Mobile Phase: 66.3:33.7 (v/v) Water with
Phosphoric Acid, pH 2.5:Methanol
15 2
1 N = 10538 plates Temperature: 30C
mAU
Accucore
30
25 2
N = 18274 plates
Accucore XL C8 pH Range
20 1 S/N = 1202
15
mAU
10 0 2 to 9 14
Similar selectivity to C18 with lower retention
5 Hydrophobicity
Recommended
0 for analytes with moderate hydrophobicity
-5 Low High
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 Pore Size
Accucore XL C8 is recommended forMinutes
analytes with moderate hydrophobicity,
or when a less hydrophobic phase provides optimum retention. 0 80 300
Carbon Load (%)
0 4 25
Endocrine Disruptors
Particle Size 4m USP L7
400 1
Accucore XL C18
Accucore XL C8 4m, 150 x 4.6mm
300 Fully Porous C18 Fully porous C8 5m, 150 x 4.6mm
3
1 2 Mobile Phase A: Water
Rs = 5.14
200 3 Rs = 4.12 Mobile Phase B: Acetonitrile
mAU
2 5
4 5 Gradient: Time (min) % B
100 4 0.0 25
20.0 70
0 20.1 75
0 1 2 3 4 5 6 7 8 9 10 25.0 25
Minutes Flow rate: 1.5mL/min
Temperature: 25C
Detection: UV at 220nm
400 1 Injection volume: 5L
Analytes 1.Desethyl Atrazine 3.Atrazine
300 2.Simazine 4.Diuron 5.Bisphenol A
3
Accucore
200 XL 2 Rs = 5.14
mAU
5
Particle Size (m) Format 4 Chemistry Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
100
40 Drop-in Guard (4/pk) C18 10 74104-012101 74104-013001 74104-014001
0 1 2 3 HPLC4 Column5 6 7 8 9 50
10 74104-052130 74104-053030 74104-054630
Minutes
100 74104-102130 74104-103030 74104-104630
150 74104-152130 74104-153030 74104-154630
250 74104-252130 74104-253030 74104-254630
Drop-in Guard (4/pk) C8 10 74204-012101 74204-013001 74204-014001
HPLC Column 50 74204-052130 74204-053030 74204-054630
100 74204-102130 74204-103030 74204-104630
150 74204-152130 74204-153030 74204-154630
250 74204-252130 74204-253030 74204-254630
www.thermoscientific.com/chromatography 4-019
LC Columns and Accessories
Improved Sensitivity
Excellent peak symmetry
Enhanced Resolution
Separation of complex samples
Thermo Scientific Chromatography Columns and Consumables 2016-2017
pH Stability
Robust assays at extended pH
The Hypersil GOLD web page contains the latest news, applications
and downloads for the Hypersil GOLD HPLC column range.
Visit www.thermoscientific.com/hypersilgold
4-020
Hypersil GOLD
70
Detection: +ESI
60 1 Analytes: 1. Atenolol
5
2. Nadolol
50 3. Pindolol
4
Hypersil GOLD
40 4. Timolol
2 5. Metoprolol
30 6. Oxprenolol
7. Propanolol
20
10
0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Minutes
Hypersil GOLD
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.9 UHPLC Column 20 - 25002-022130 - - -
30 25002-031030 25002-032130 - - -
50 25002-051030 25002-052130 25002-053030 - 25002-054630
100 25002-101030 25002-102130 25002-103030 - -
150 - 25002-152130 - - -
200 - 25002-202130 - - -
3 Drop-in Guard (4/pk) 10 25003-011001 25003-012101 25003-013001 25003-014001 25003-014001
HPLC Column 30 - 25003-032130 - - 25003-034630
50 - 25003-052130 25003-053030 25003-054030 25003-054630
100 25003-101030 25003-102130 25003-103030 25003-104030 25003-104630
150 25003-151030 25003-152130 25003-153030 25003-154030 25003-154630
5 Drop-in Guard (4/pk) 10 - 25005-012101 25005-013001 25005-014001 25005-014001
HPLC Column 30 - 25005-032130 25005-033030 - 25005-034630
50 - 25005-052130 25005-053030 - 25005-054630
100 - 25005-102130 25005-103030 - 25005-104630
150 - 25005-152130 25005-153030 25005-154030 25005-154630
250 - 25005-252130 25005-253030 25005-254030 25005-254630
UNIGUARD Drop-in 10 851-00 852-00 852-00 850-00 850-00
Guard Cartridge
Holder
www.thermoscientific.com/chromatography 4-021
Hypersil GOLD Preparative
LC Columns and Accessories
Particle Size (m) Format Length (mm) 10mm ID 20mm ID 21mm ID 30mm ID 50mm ID
5 Preparative Guard 10 25005-019023 25005-019223 - - -
Cartridge (3/pk)
Preparative HPLC 50 25005-059070 - - 25005-059370 25005-059570
Column
100 25005-109070 - 25005-109270 25005-109370 25005-109570
150 25005-159070 - 25005-159270 25005-159370 25005-159570
250 25005-259070 - 25005-259270 25005-259370 25005-259570
12 Preparative Guard 10 25012-019023 25012-019223 - - -
Cartridge (3/pk)
Preparative HPLC 50 25012-059070 - 25012-059270 25012-059370 25012-059570
Column
100 25012-109070 - 25012-109270 25012-109370 25012-109570
150 - - 25012-159270 25012-159370 25012-159570
250 25012-259070 - 25012-259270 25012-259370 25012-259570
Preparative Guard 10 C-1000 854-00 - - -
Cartridge Holder
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-022
Hypersil GOLD C8
Outstanding sensitivity
b-carotene
600 1
Hypersil GOLD C8 5m, 150 x 4.6mm
Mobile Phase: MeOH
Temperature: 25C
500
Flow Rate: 1.5mL/min
Detection: UV, 450nm
400 Analytes: 1. Lutein
2. Lycopene
Hypersil GOLD
3. -Carotene
300
mAU
200
2 3
100
0 1 2 3 4 5 6 7
Minutes
Hypersil GOLD C8
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.9 UHPLC Column 20 - 25202-022130 - - -
30 - 25202-032130 - - -
50 - 25202-052130 25202-053030 - 25202-054630
100 25202-101030 25202-102130 25202-103030 - -
150 - 25202-152130 - - -
3 Drop-in Guard (4/pk) 10 25203-011001 25203-012101 25203-013001 25203-014001 25203-014001
HPLC Column 50 - 25203-052130 25203-053030 25203-054030 25203-054630
100 25203-101030 25203-102130 25203-103030 25203-104030 25203-104630
150 - 25203-152130 25203-153030 25203-154030 25203-154630
5 Drop-in Guard (4/pk) 10 - 25205-012101 25205-013001 25205-014001 25205-014001
HPLC Column 50 - 25205-052130 25205-053030 - 25205-054630
100 - 25205-102130 25205-103030 - 25205-104630
150 - 25205-152130 25205-153030 25205-154030 25205-154630
250 - 25205-252130 25205-253030 25205-254030 25205-254630
UNIGUARD Drop-in 10 851-00 852-00 852-00 850-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-023
Hypersil GOLD C4
LC Columns and Accessories
pH Range
Fatty acids
2. Linoleic acid
80
40
0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Minutes
Hypersil GOLD C4
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.6mm ID
1.9 UHPLC Column 50 - 25502-052130 - -
100 - 25502-102130 - -
150 - 25502-152130 - -
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-024
Hypersil GOLD aQ
3. Vitamin B3 (nicotinamide)
400
4. Vitamin B5 (pantothenic acid)
5. Folic Acid
-
4
200 7 6. Vitamin B12 (cyanocobalamin)
Hypersil GOLD
5 7. Vitamin H (biotin)
0 8. Vitamin B2 (riboflavin)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Minutes
Hypersil GOLD aQ
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.9 UHPLC Column 20 - 25302-022130 - - -
30 - 25302-032130 - - -
50 25302-051030 25302-052130 25302-053030 - 25302-054630
100 25302-101030 25302-102130 25302-103030 - -
150 - 25302-152130 - - -
200 - 25302-202130 - - -
3 Drop-in Guard (4/pk) 10 25303-011001 25303-012101 25303-013001 25303-014001 25303-014001
HPLC Column 30 - 25303-032130 25303-033030 - -
50 - 25303-052130 25303-053030 25303-054030 25303-054630
100 25303-101030 25303-102130 25303-103030 25303-104030 25303-104630
150 25303-151030 25303-152130 25303-153030 25303-154030 25303-154630
5 Drop-in Guard (4/pk) 10 - 25305-012101 25305-013001 25305-014001 25305-014001
HPLC Column 50 - 25305-052130 25305-053030 - 25305-054630
100 - 25305-102130 25305-103030 - 25305-104630
150 - 25305-152130 25305-153030 - 25305-154630
250 - 25305-252130 - 25305-254030 25305-254630
UNIGUARD Drop-in 10 851-00 852-00 852-00 850-00 850-00
Guard Cartridge Holder
www.thermoscientific.com/chromatography 4-025
Hypersil GOLD PFP
LC Columns and Accessories
pH Range
Low High
Pore Size
Fluorine atoms around the phenyl ring enhance pi-pi interactions
with aromatic molecules 0 175 300
Extra retention for halogenated species Carbon Load (%)
2. Hydroquinone
30000 3. Resorcinol
4. Phenol
20000
4
1
10000
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Minutes
Antidepressants
Hypersil GOLD
20 4 2. Acetaminophen
imp 3. p-Hydroxybenzoic acid
4. o-Hydroxybenzoic acid
0 5. Oxazepam
6. Diazepam
0.0 1.0 2.0 3.0 4.0
7. Di-isopropyl phthalate
Minutes
8. Di-n-propyl phthalate
www.thermoscientific.com/chromatography 4-027
Hypersil GOLD CN
LC Columns and Accessories
pH Range
Low High
Provide alternative selectivity with lower hydrophobicity
Pore Size
Excellent peak shape
0 175 300
Outstanding sensitivity
Carbon Load (%)
Less retention for faster analysis
0 4 25
Organic acids
60 2. o-Toluic Acid
2 3. p-Toluic Acid
4. 2,4,6-Trimethylbenzoic Acid
55 5. 2,5-Dimethylbenzoic Acid
50
Hypersil GOLD CN
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.9 UHPLC Column 50 - 25802-052130 - - -
100 - 25802-102130 - - -
200 - 25802-202130 - - -
3 Drop-in Guard (4/pk) 10 25803-011001 25803-012101 25803-013001 25803-014001 25803-014001
HPLC Column 30 - 25803-032130 - - -
50 - 25803-052130 - - -
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-028
Hypersil GOLD Amino
Retains anions and organic acids in weak anion exchange 0 175 300
Carbon Load (%)
Excellent for carbohydrate analysis in reversed-phase
Alternative selectivity to silica columns in normal phase chromatography 0 2 25
Outstanding peak shape and sensitivity Particle Size 1.9m, 3m, 5m USP L8
Sugars
Hypersil GOLD
uRIU
3 2. Glucose
6
2 3. Sucrose
4 4. Maltose
4
5. Lactose
2
5
0
0 2 4 6 8 10 12 14 16 18 20
Minutes
www.thermoscientific.com/chromatography 4-029
Hypersil GOLD AX
LC Columns and Accessories
pH Range
Vitamin C
20
0 5 10 15 20 25
Minutes
Hypersil GOLD AX
Particle Size (m) Format Length (mm) 1.0mm ID 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.9 UHPLC Column 50 - 26102-052130 - - -
100 - 26102-102130 - - -
150 - 26102-152130 - - -
200 - 26102-202130 - - -
3 Drop-in Guard (4/pk) 10 26103-011001 26103-012101 26103-013001 26103-014001 26103-014001
HPLC Column 30 - 26103-032130 - - -
Thermo Scientific Chromatography Columns and Consumables 2016-2017
50 - 26103-052130 - - -
100 - 26103-102130 - - 26103-104630
150 26103-151030 26103-152130 26103-153030 - 26103-154630
5 Drop-in Guard (4/pk) 10 - 26105-012101 26105-013001 26105-014001 26105-014001
HPLC Column 50 - - - - 26105-054630
100 - 26105-102130 - - 26105-104630
150 - 26105-152130 - - 26105-154630
250 - 26105-252130 26105-253030 26105-254030 -
UNIGUARD Drop-in 10 851-00 852-00 852-00 850-00 850-00
Guard Cartridge Holder
4-030
Hypersil GOLD SAX
Monophosphates
100
Hypersil GOLD
75
mAU
50
25
0 1 2 3 4 5 6 7 8
Minutes
www.thermoscientific.com/chromatography 4-031
Hypersil GOLD Silica
LC Columns and Accessories
pH Range
0 25
90
Hypersil GOLD Silica 5m, 150 x 4.6mm
80 Mobile Phase: 19:1 (v/v) n-C6H14/EtOH
Temperature: 30C
70
Flow Rate: 1.5mL/min
60 Injection volume: 5L
Detection: UV, 254nm
50 Analytes: 1. Progesterone
2. 21-Hydroxyprogesterone-21-acetate
mVolts
40
3. 17-a-Hydroxyprogesterone
30 4. Cortisone
5. 11-a-Hydroxyprogesterone
20 6. Corticosterone
7. Hydrocortisone
10
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Minutes
50 - 25103-052130 - - -
100 - 25103-102130 25103-103030 - -
150 25103-151030 25103-152130 25103-153030 - 25103-154630
5 Drop-in Guard (4/pk) 10 - 25105-012101 25105-013001 25105-014001 25105-014001
HPLC Column 50 - 25105-052130 - - -
100 - 25105-102130 25105-103030 - 25105-104630
150 - 25105-152130 - - 25105-154630
250 - 25105-252130 - 25105-254030 25105-254630
UNIGUARD Drop-in 10 851-00 852-00 852-00 850-00 850-00
Guard Cartridge Holder
4-032
Hypersil GOLD HILIC
Urea
100 Hypersil GOLD HILIC 5m, 150 x 4.6mm
Mobile Phase: H 2 O/MeCN (10:90)
+ 0.1% formic acid
80
Temperature: 30C
Flow Rate: 0.6mL/min
Relative Abundance
60 Injection Volume: 1L
Detection: +ESI
Analytes: 1. Urea
40
Hypersil GOLD
20
0
0 1 2 3 4 5 6 7 8 9 10
Minutes
www.thermoscientific.com/chromatography 4-033
LC Columns and Accessories
Acclaim HPLC
and UHPLC Columns
Optimal selectivity through innovative
chemistries
Designed for separating a variety of analytes, from small neutral and polar
molecules to complex mixtures. Ideal for pharmaceutical, environmental,
food and beverage and chemical applications.
Diversified Selectivities
Novel and proprietary surface chemistries
O OH
Reproducible and Reliable
Strict manufacturing and quality processes O
High Efficiencies O
For optimum resolution of complex mixtures
Ultra-pure, Porous,
Thermo Scientific Chromatography Columns and Consumables 2016-2017
Spherical Silica
Providing consistent quality and performance
4-034
Acclaim 120 C18
Low High
High hydrophobic retention
Pore Size
Excellent efficiencies for maximum resolution
0 120 300
Low silanol activity for excellent peak shapes for basic analytes
Carbon Load (%)
Extremely low bleed, fully compatible with MS
0 18 25
The Acclaim 120 columns are designed for high resolution reversed-phase separations.
The very high surface coverage and very low metal content together result in columns
with excellent efficiencies. These columns provide exceptional performance for
a variety of applications in the pharmaceutical, chemical, environmental and food
separations areas. A: Acclaim 120 C18, 5m, 150 x 4.6mm
B, C: Acclaim RSLC C18, 2.2m, 50 x 2.1mm
Mobile Phase: 200mM HOAc
in 10% (v/v) MeOH
160 250 220 Column:
Temperature: A: Acclaim 120 C18, 5m,
20C Detector: UV
4 Flow Rate: A: 1.00mL/min
A 4 B 4 C
4.6150
B: 0.41mL/min
mm A: 1
B,C: C: Acclaim RSLC C18, 2m, B:
Acclaim
0.82mL/min
Injection Volume: 2.150
A: 10L mm C: 1
B: 1.2L
Mobile
Phase: 200 mM HOAc
C: 1.2L Peaks: 1. p
mAU
www.thermoscientific.com/chromatography 4-035
Acclaim 120 C8
LC Columns and Accessories
pH Range
Acclaim 120 C8 reversed-phase columns feature densely bonded monolayer C8 ligands Particle Size 2.2m, 3m, 5m USP L7
Triclosan in toothpaste
Column: Acclaim RSLC C8, 2.2m, 50 x 2.1mm
80 Mobile Phase: Isocratic,Acclaim
15% buffer, (2mM
2 Column:
RSLC C8, 2.2 m
Ammonium acetate pH5),
Dimension: 2.1 100 mm
85% methanol (v/v)
HPLC System:
Temperature: 50C UltiMate 3000 RSLC
281.1 Buffer:
Flow Rate: 0.2mL/min 2 mM Ammonium acetate pH 5
Mobile Phase:
Injection Volume: 1.0L Isocratic, 15% buffer, 85% methanol (v/v)
200 nm 400 Flow Rate:
Detection: 0.200
Diode array mL/min
detector, 281nm,
1 Volume: 10Hz, 0.11.0
s resp.
Inj. L time and spectra
mAU
Temperature: 20040050 nmC
Analytes: 1. Saccharin
Detection:
Diode array detector, 281 nm, 10 Hz,
2. Triclosan
Sample: Toothpaste0.1containing
s resp. time
0.3%and spectra 200400 nm
triclosan
Samples: Toothpaste containing 0.3% triclosan
Preparation: 1.0 g Toothpaste + 1.0 mL of 7.5 mg/mL
magnesium sulfate + methanol to make
25 mL. Sonicate and filter.
0 Peaks:
0.0 1.0 2.0 3.0 1. Saccharin
Minutes 2. Triclosan
Acclaim 120 C8
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.2 RSLC Column 30 - 072618 -
Thermo Scientific Chromatography Columns and Consumables 2016-2017
50 072615 072619 -
100 072616 072620 -
150 072617 - -
250 074811 - -
3 HPLC Column 50 059122 - 059125
100 059123 - 059126
150 059124 068970 059127
250 076185 - -
5 Guard Cartridge 10 069688 071979 069696
HPLC Column 50 059134 - 059138
100 - - 059139
150 059136 - 059140
250 - - 059141
See page 4-037 for Acclaim Guard Holder Ordering Guide
4-036
Acclaim Phenyl-1
Low High
High aromatic selectivity
Pore Size
High hydrophobic retention
0 120 300
Unique and complementary selectivity compared to any other phenyl
Carbon Load (%)
type column
Compatibility with highly aqueous mobile phase 0 13 25
High efficiency and rugged packing Particle Size 3m, 5m USP L11
Acclaim Phenyl-1 has a higher pi-pi interaction than other phenyl phases and provides
unique selectivity for aromatic compounds while maintaining sufficient hydrophobic
interaction and aqueous compatibility for superior chromatographic performance.
The Acclaim Phenyl-1 column can be used in a wide range of applications in
pharmaceutical, environmental, food testing and product-quality testing. This column is
ideally suited for the analysis of aromatic analytes; some examples include
glucocorticosteroids, estrogens, fat-soluble vitamins and phospholipids.
Acclaim
Separation of fat-soluble vitamins Acclaim Phenyl-1, 3m, 150 x 3.0mm
Mobile Phase: Methanol/water v/v 90/10
60
Temperature: 30C
2 Flow Rate: 0.5mL/min
3
Injection Volume: 2L
Detection: UV, 220nm
Analytes: (100 ppm each)
1. Retinol acetate (vitamin A acetate)
5 2. Vitamin D2
4
mAU
3. Vitamin D3
6 9 4. delta-Tocopherol
8
5. gamma-Tocopherol
6. alpha-Tocopherol (vitamin E)
1 10 7. Impurity (unknown)
7
8. Vitamin E acetate
9. Vitamin K2
10. Vitamin K1
0
0 6 12 18 24 30
Minutes
Acclaim Phenyl-1
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
3 Guard Cartridge 10 079934 071974 071973
HPLC Column 150 071971 071970 071969
5 HPLC Column 150 - - 088016
250 - - 079697
www.thermoscientific.com/chromatography 4-037
Acclaim C30 pH Range
LC Columns and Accessories
Low High
High shape selectivity Pore Size
Unique selectivity complementary to other reversed-phase columns
0 200 300
Compatibility with highly aqueous mobile phase Carbon Load (%)
High-quality: low column bleed, high efficiency and rugged packing
0 13 25
900:3.6:100 (v/v)
100 0 100
Mobile Phase B: Acetone:acetonitrile:THF:formic 0 acid
0 14
675:225:100:4(v/v) 1 40 60
0 9 11
Area 13 Gradient: 13 (min) %A 30 %B 70
Time
8 10 0 22 100 0 5 95
12 1 40 60
2 9 24 5 95
34 13 30 70
1 6 7 22 29 100
5 95 0
A 24 32 100
5 95 0
pA
5
Flow Rate:
1.00
29 mL/min100 0
Temperature: 3032 C 100 0
Temperature:
Inj. Volume: 2 30CL
Flow Rate: 1.00mL/min
Detection: Corona ultra, nebulizer 15 C, filter high
Injection Volume: 2L
B Samples:
Detection:
A.Corona
Standards in isopropanol
ultra, nebulizer 15C, filter high
Analytes: B.1.Saponified
SDA chicken fat
0 Peaks: 1.2.SDA
EPA 8. DPA
10 12 14 16 18 20 22 24 3. ALA
Minutes
2.4.EPA
GLA
9. 9E, 14Z-CLA
3.5.ALA
DHA 10. ETA
4.6.GLA
Arach. 11. Adrenic
5.7.DHA
LLA 12. Oleic
Samples: A. Standards
6. Arach. in
13.isopropanol
EDA
B. Saponified chicken fat
7. LLA 14. Erucic
Acclaim C30
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-038
Acclaim PolarAdvantage pH Range
Low High
Selectivity complementary to the C18 column Pore Size
Low silanol activity for excellent peak shape with basic compounds
0 120 300
Compatible with 100% aqueous mobile phase Carbon Load (%)
High selectivity for hydrophobic aromatic molecules
0 16 25
Wide range of applications
Particle Size 2.2m, 3m, 5m USP L60
Acclaim PolarAdvantage (PA) columns feature a patented bonding column chemistry that incorporates
a polar sulfonamide group with an ether linkage near the silica surface. This unique chemistry provides
low silanol activity, compatibility with 100% aqueous mobile phase. The Acclaim PA column offers great
separation power to resolve a wide variety of polar and non-polar analytes and supports LC-MS analysis.
Acclaim
7 Mobile Phase B: Acetonitrile
Gradient: -1.5 0.0 0.3 2.6 3.0
%A 70 70 70 10 10
%B 30 30 30 90 90
5 Temperature: 30C
Flow Rate: 1.25mL/min
3 Injection Volume: 0.5L
2
mAU
Acclaim PolarAdvantage
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.2 RSLC Column 50 072622 - -
75 - 075698 -
100 072623 072627 -
150 072624 - -
250 074813 - -
3 HPLC Column 50 063174 068972 -
100 061316 076214 -
150 061317 063693 061318
250 - 070079 -
5 Guard Cartridge 10 069691 071983 069698
HPLC Column 50 - - 061319
150 - - 061320
250 - - 061321
www.thermoscientific.com/chromatography 4-039
Acclaim PolarAdvantage II pH Range
LC Columns and Accessories
Low High
Unique selectivity complementary to the C18 column Pore Size
Novel polar-embedded column chemistry for hydrolytic stability
0 120 300
Compatible with 100% aqueous mobile phase Carbon Load (%)
Low bleed for MS compatibility
0 16 25
Wide range of applications
Particle Size 2.2m, 3m, 5m USP L60
Acclaim PolarAdvantage II (PA2) columns feature a patented surface chemistry that incorporates
an amide-embedded polar group and multi-point attachment between the ligands and the silica surface.
This unique chemistry provides enhanced hydrolytic stability from pH 1.5-10 with 100% aqueous mobile
phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional
C18 columns.
The Acclaim PA2 column is specifically designed to withstand high pH conditions, making it a good choice
for the separation of both basic and acidic analytes.
Turmeric
200 1, 2, 3 Acclaim RSLC 120 C18 2.2m, 100 x 2.1mm
Acclaim RSLC PA2, 2.2m, 100 x 2.1mm
Mobile Phase A: 15mM H 3PO 4
Mobile Phase B: Methanol
Area: 9.7 mAU*Min. Isocratic: C18: 70% B (v/v)
C18 PA2: 80% B (v/v)
mAU
1 Temperature: 30C
Flow Rate: 0.41mL/min
Total area: 9.9 mAU*Min. Detection: UV, 428nm
2 3 Analytes: 1. Curcumin
PA2 2. Demethoxycurcumin
0 3. Bis-demethoxycurcumin
Sample: Turmeric extract
0 1 2 3 4
Minutes
Acclaim PolarAdvantage II
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-040
Acclaim HILIC-10 pH Range
Low High
Retains highly polar molecules that are not retained by Pore Size
reversed-phase chromatography
0 120 300
Unique selectivity, complementary to reversed-phase columns
Particle Size 3m, 5m
Hydrolytically stable
Rugged column packing
Broad application range
The Acclaim HILIC-10 column is designed for separating highly hydrophilic molecules by Hydrophilic
Interaction Liquid Chromatography (HILIC). This column is based on high-purity spherical porous silica
covalently modified with a proprietary hydrophilic layer.
Acclaim
Glycerides
200
Acclaim HILIC-10, 3m, 150 x 3.0mm
Mobile Phase A: Heptane
Mobile Phase B: 2-Propanol/acetic acid 99.5:0.5
Temperature: 25C
4 Flow Rate: 0.50mL/min
2
Injection Volume: 4L
1 3 Detection: Corona ultra, nebulizer 15C
Analytes: 1. Tristearin
pA
7 2. Trilaurin
8 3. Distearin isomer 1
5 4. Dilaurin isomer 1
5. Distearin isomer 2
6. Dilaurin isomer 2
7. Monostearin
6 8. Monolaurin
0
0 2 4 6 8 10
Minutes
Acclaim HILIC-10
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
3 HPLC Column 150 074259 074258 074257
5 Guard Cartridge 10 074263 074261 074262
www.thermoscientific.com/chromatography 4-041
Acclaim Mixed-Mode HILIC-1
LC Columns and Accessories
pH Range
Uniquely designed for both reversed-phase and HILIC operations 0 2.5 to 7.5 14
Hydrophobicity
Low High
Can operate in both RP and HILIC modes
Pore Size
Retains highly polar molecules
0 120 300
Unique selectivity complementary to RP columns
Particle Size 3m, 5m
Broader application range compared with conventional diol-based columns
High-efficiency column for high-resolution separations
1
Acclaim Mixed-Mode HILIC-1, 5m, 150 x 4.6mm
Reversed-Phase Mode
Mobile Phase: CH 3CN/0.1 M NH 4OAc, pH 5.2
2 v/v 52/48 for RP mode
v/v 92/8 for HILIC mode
Temperature: 30C
AU
0 2 4 6 8 10
Minutes
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-042
Acclaim Mixed-Mode WAX-1
Designed for separating anionic molecules with powerful adjustable 0 2.5 to 7.5 14
Hydrophobicity
selectivity control
Low High
Pore Size
Adjustable selectivity
Selectivity orthogonal to reversed-phase (RP) columns 0 120 300
Ideal selectivity for anionic molecules Particle Size 3m, 5m USP L78
The Acclaim Mixed-Mode WAX-1 is a novel, high-efficiency silica HPLC column that
combines hydrophobic and weak anion exchange characteristics. Its unique chemistry
results in a multimode separation mechanism that includes reversed-phase, anion
exchange, and HILIC interactions. Selectivity can be adjusted by changing ionic strength,
pH or organic solvent content.
Acclaim
Pain relief medicine
0 10 20
Minutes
www.thermoscientific.com/chromatography 4-043
Acclaim Mixed-Mode WCX-1
LC Columns and Accessories
pH Range
Pharmaceutical counterions
0 4 8
Minutes
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-044
OmniPac
0 60 1200 1500
PAX-100 PAX-500
Thermo Scientific OmniPac is a range of latex-based columns. Both PAX columns have an
ion exchange capacity of about 40eq per column, and the PCX columns have a capacity of
approximately 120eq per column. The PAX-500 and PCX-500 columns separate analytes
through both ion exchange and reversed-phase mechanisms, due to their higher reversed-
phase capacity relative to the PAX-100 and PCX-100 columns.
OmniPac
Gradient separation of nitrogen-containing compounds
16
12 OmniPac PCX-500, 250 x 4.0mm
13 Mobile Phase: Acetonitrile/Sodium Chloride/
9 Hydrochloric Acid Gradient
6,7 Flow Rate: 1.0mL/min
Detection: UV, 254nm
Analytes: 1. Orotic Acid
1 2 4,5
11 2. 4-Hydroxybenzamide
10
3. Luminol Impurity
17 4. Luminol
5. Pyridine
8 14 15 6. PABA
3 7. 2,2-Bipyridine
8. p-Phenylenediamine
9. Naphthylamine
0 5 10 15 10. Nitrobenzoic Acid
Minutes 11. Tribenzylamine
12. p-Nitroaniline
13. 2,4-Dinitroaniline
14. Dibenzylamine
15. N-Methyl-N-nitrosoaniline
16. 4-Chloro-2-nitroaniline
17. 2,6-Dichloro-4-nitroaniline
www.thermoscientific.com/chromatography 4-045
Acclaim Size Exclusion Chromatography (SEC) pH Range
LC Columns and Accessories
Pore Size
0 1500
Proprietary mono-dispersed multi-pore hydrophilic resin: no inflection points 300 (SEC 300) 1000 (SEC 1000)
Availability of small particle sizes packed in 300 x 4.6mm dimension allows for
high-resolution analysis at reduced solvent consumption
Stable surface bonding with low column bleed and compatibility with UV, RI, MS,
ELSD and Thermo Scientific Dionex Corona Charged Aerosol Detectors
Thermo Scientific Acclaim SEC-300 and SEC-1000 are a family of resin based, high performance size
exclusion chromatography columns specifically designed for the separation of water soluble polymers
and oligomers.
100,000,000
PAA
Mobile Phase B: Water
Area [ pA *min]
Temperature: 30C
Flow Rate: 0.35mL/min
0.200
Injection Volume: 35L
400 g/L Detection: Corona III; evaporator 55C, Engine
Concentration [ g/L] 40 C, 2 Hz, filter 5, power function
200 g/L 0.00c0 1.20
0 125 250 375 500 Analytes: 1. PAA standards in water
100 g/L
50 g/L
25 g/L
-0.0
0 5 Minutes 10 15
www.thermoscientific.com/chromatography 4-047
LC Columns and Accessories
Surfactant Plus
Separation of surfactants
Acclaim Explosives
Separation of explosive residues
4-048
Acclaim AmG C18
Aminoglycoside antibiotics are commonly used as clinical and veterinary medicines to treat bacterial
infections. HPLC using ion-pairing reversed-phase separations is an effective technique for simultaneous
qualitative and quantitative determination of aminoglycosides.
Acclaim
The Acclaim AmG C18 column is designed to provide excellent stability, selectivity and high resolution. It
has a unique surface, a polymer encapsulated silica covalently bonded with a C18 ligand. This ensures
ultra-stability when exposure to low pH (<1) and high temperature separation conditions.
Isocratic separation of gentamicin sulfate using 100 mM TFA as the mobile phase
10.0
C1a Acclaim AmG C18, 3m, 150 x 3.0mm
Mobile Phase: 100 mM TFA
Temperature: 30C
R1 R2 R3
7.5 Flow Rate: 0.425 mL/min
C 1a H H H
C2 H CH 3 H Injection Volume: 2L
C 2b CH 3
H H Detection: Corona Veo RS (Filter =
C 2a H H CH 3 5.0 s; Evaporation Temp =
C1 CH CH H
3 3
35 C; Data Rate = 5 Hz;
5.0 C2
Current [pA]
2.5
C2b
0.0
www.thermoscientific.com/chromatography 4-049
Acclaim Trinity P1
LC Columns and Accessories
The Thermo Scientific Acclaim Trinity P1 HPLC column is designed with Nanopolymer Silica Hybrid (NSH) technology, which results in a multimode
surface chemistry ideal for the simultaneous separation of drugs and their counterions. The surface chemistry concurrently provides reversed-phase,
cation exchange, and anion exchange functionalities. The result is maximum flexibility in method development. Separations can be optimized
easily by adjusting the chromatographic parameters (mobile phase pH, ionic strength, and organic strength).
1 Analytes: 1. Choline
4 (50 to 100ppm) 2. Tromethamine
2 3. Sodium
4. Potassium
5. Meglumine
8
6 6. Mesylate
5
7. Nitrate
7 9 10 8. Chloride
9. Bromide
0 10. Iodide
0 3 6 9 12 15
Minutes
Acclaim Trinity P1
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-050
Acclaim Trinity P2
The Acclaim Trinity P2 is a unique, high-efficiency, silica-based column specifically designed for separation of pharmaceutical counterions, including
monovalent and divalent cations or anions. This column is based on Nanopolymer Silica Hybrid (NSH) technology, which consists of high-purity
porous spherical silica particles coated with charged nanopolymer particles. The inner-pore area of the silica bead is modified with a covalently
bonded organic layer that provides cation-exchange retention, while the outer surface is modified with anion-exchange nano-polymer beads.
Acclaim Trinity P2 column is aimed to complement Acclaim Trinity P1 to provide a total solution for pharmaceutical counter ion analysis by HPLC.
Acclaim
Pharmaceutical-related anions and cations
Acclaim Trinity P2, 3m, 100 x 3.0mm
5.0 Mobile Phase: D.I. water and 100 mM NH4OFm, pH
3.65 gradient
Temperature: 30C
Flow Rate: 0.60 mL/min
Injection Volume: 2L
Detection: Corona Veo Charged Aerosol Detector
1
Analytes: 1. Phosphate
2 2. Sodium
3. Potassium
10 4. Chloride
5. Malate
6. Bromide
6 11 7. Nitrate
9
pA 8. Citrate
9. Fumarate
10. Sulfate
5 8 11. Magnesium
3 12. Calcium
Samples: 0.02 0.10 mg/mL each in D.I. water
12
4
7
Time (min) H2O 0.1 M Ammonium formate, pH3.65
-10 0.760 1.474
0 80 20
0
2 80 20
0 6 12 18 24 30 22 0 100
Minutes 30 0 100
Acclaim Trinity P2
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID
3 Guard Cartridges 10 085435 085436
(2/pk)
HPLC Column 50 085431 085433
100 085432 085434
www.thermoscientific.com/chromatography 4-051
Acclaim Organic Acid
LC Columns and Accessories
The Acclaim Organic Acid (OA) is a silica-based reversed-phase column designed for high-efficiency, high-throughput organic acids analysis.
It offers unparalleled performance for separating hydroxyl aliphatic and aromatic organic acids.
The Acclaim OA is the recommended column for determining small hydrophilic organic acids, C1 to C7 aliphatic acids, and hydrophilic aromatic
acid and is also valuable for the analysis and quality assurance of food and beverage products, pharmaceutical preparations, plating baths, and
manufacturing chemicals, chemical intermediates, and environmental samples.
2
Analytes: 1. Oxalic acid 15mg/L (ppm)
2. Tartaric acid 120
3. Formic acid 180
1 3 4 12 4. Malic acid 120
8 5. iso-Citric acid 120
567 9 11 6. Lactic acid 180
7. Acetic acid 120
0
8. Citric acid 120
0 5 10 15 9. Succinic acid 120
Minutes 10. Fumaric acid 7
11. cis-Aconitic acid *
12. trans-Aconitic acid *
* 7ppm total for cis and trans isomers
4-052
Acclaim Surfactant
The Acclaim Surfactant columns are the first generation high-efficiency, silica-based columns designed specifically for separating a wide variety of
surfactants, including anionic, cationic, nonionic, ethoxylated and amphoteric surfactants using UV, ELSD or RI detection.
Surfactants are widely used in industrial, agricultural, and pharmaceutical markets, in products as diverse as pesticides, detergent powders,
petroleum products, cosmetics, and pharmaceuticals. The Acclaim Surfactant column was designed specifically for HPLC separation
of these surfactants.
Acclaim
Inorganic anion, hydrotropes, cationic, nonionic, amphoteric, and anionic surfactants
3
Flow Rate: 1mL/min
2 4 Injection Volume: 25L
7 9 13 Detection: ELS detector
8
1 12 Analytes: 1. Chloride
11 14 2. Bromide
3. Nitrate
4. Xylene sulfonate
0 5 10 15 20 25 30 35 5. Laurylpyridinium chloride
Minutes 6. Lauryldimethylbenzyl-ammonium chloride
7. Triton X-100
8. Cetyl betaine
9. Decyl sulfate
10. Dodecyl sulfate
11. C10 -LAS
12. C11-LAS
13. C12 -LAS
14. C13 -LAS
Acclaim Surfactant
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
3 HPLC Column 150 070085 070084
5 Guard Cartridges 10 069693 071991 069701
(2/pk)
HPLC Column 150 068123 063201
250 063203
www.thermoscientific.com/chromatography 4-053
Acclaim Surfactant Plus
LC Columns and Accessories
Acclaim Surfactant Plus is a new generation of columns offering improved performance and higher throughput for analyzing surfactants. These
columns exhibit exceptionally low bleed and are ideal for use with charged aerosol detectors (CAD) and mass spectrometers (MS). These columns
can be used to separate a wide variety of surfactants including anionic, cationic, nonionic and amphoteric surfactants, as well as isomers of
xylene sulfonate.
These columns can be used with evaporative light scattering detectors (ELSD), suppressed conductivity detectors (SCD), and UV-Vis detectors (UV).
Non-metallic PEEK hardware is available for best compatibility with Dionex ion chromatography systems.
Temperature: 25C
Flow Rate: 0.5mL/min
5 6
7 Injection Volume: 5L
5 Detection: Conductivity with blank subtraction
S 8 Analytes: 1. Tetrabutylammonium
2. Tetrapentylammonium
3. Tetrahexylammonium
4. Tetraheptylammonium
5. Decyl-trimethylammonium
0 6. Dodecyl-trimethylammonium
7. Tetradecyl-trimethylammonium
8. Hexadecyl-trimethylammonium
Thermo Scientific Chromatography Columns and Consumables 2016-2017
0 5 10 15
Minutes
4-054
Acclaim Explosives E2
Acclaim Explosives E2 columns are specifically designed to resolve all 14 explosives listed in EPA SW-846 Method 8330: Nitroaromatics and
Nitramines by HPLC. The novel and unique chemistries of these columns provide superior resolution with complementary selectivities.
The Acclaim Explosives E2 may be used as either a primary or a confirmatory column. The unique selectivity and versatility of this column
provides a wider application range, including the analysis of explosives beyond U.S. EPA Method 8330 (ISO22478).
Acclaim
60
4 Acclaim RSLC Explosives E2, 2.2m, 100 x 2.1mm
Mobile Phase: Methanol:water 48:52 (v/v)
3
Temperature: 31C
Flow Rate: 0.34mL/min (293 bar)
Injection Volume: 1L
5 9 Detection: UV, 254nm
6 Analytes: 1. HMX 8. 2,6-DNT
mAU
2. RDX 9. 2,4-DNT
2 3. 1,3,5-TNB 10. 2-NT
8
1 7 14 4. 3,5-DNB 11. 4-NT
10 12 13 5. NB 12. 3-NT
11 6. 2,4,6-TNT 13. 4-Am-2,6-DNT
7. Tetryl 14. 2-Am-4,6-DNT
Sample: Calibration mix, 25g/mL
0 in 50% acetontrile
0 2.5 5 7.5 10
Minutes 28815
Acclaim Explosives E2
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.2 RSLC Column 100 076225 076227
150 076226
3 HPLC Column 150 070083 070082
250 070081
5 Guard Cartridges 10 071989 069703
(2/pk)
HPLC Column 250 064309
See page 4-054 for Acclaim Guard Holder Ordering Guide
www.thermoscientific.com/chromatography 4-055
Acclaim Trinity Q1
LC Columns and Accessories
Acclaim Trinity Q1 columns are unique, high-efficiency, silica-based columns designed for the separation of the herbicides diquat and paraquat.
These herbicides are toxic and residues are monitored in drinking water, wastewater and agricultural products. The Acclaim Trinity Q1 column is a
tri-mode (WCX, WAX, RP), column based on Nano-polymer Silica Hybrid technology. It offers unmatched high-resolution and high-throughput trace
analysis of the herbicides diquat and paraquat by LC-MS/MS and LC-UV methods.
Acclaim Trinity Q1
Particle Size Length (mm) 2.1mm ID 3.0mm ID
3 HPLC Column 50 083242 083241
100 079717 079715
5 Guard Cartridges 10 083244 079719
(2/pk)
4-056
Acclaim Carbamate
Acclaim Carbamate columns are designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides)
specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is
monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with
postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.
Acclaim
Acclaim Carbamate, 3m, 150 x 3.0mm
Mobile Phase: MethanolH 2 O
4000 Gradient: Methanol, -4.00.0 min, 14%;
4 A 2.0 min, 20%; 8.0 min, 40%;
1 13.616 min, 70%
2 9
3 Temperature: 50 C
6 10
counts 5 Flow Rate: 0.9mL/min
7 8 12 Injection Volume: 250L
11 Detection: Excitation/330nm and
1 Emission/465nm
Analytes: 1. Aldicarb sulfoxide
-500 2. Aldicarb sulfone
0 1.3 2.5 3.8 5 6.3 7.5 8.8 10 11.3 12.5 13.8 15 16 3. Oxamyl
2000 4. Methomyl
5. 3-Hydroxy carbofuran
12 B 6. Aldicarb
7. Propoxur
8. Carbofuran
counts
9. Carbaryl
2 1 2 3 4 9
10. 1-Naphthol
5 6 7 8 10 11. Methiocarb
11
12. BDMC (I.S.)
-300
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Minutes
Acclaim Carbamate
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
2.2 RSLC Column 100 075597
150 075596
3 Guard Cartridges 10 072930 072929 072928
(2/pk)
HPLC Column 150 072927 072926 072925
5 HPLC Column 250 072924
www.thermoscientific.com/chromatography 4-057
Acclaim Carbonyl C18
LC Columns and Accessories
Acclaim Carbonyl C18 columns are silica-based reversed phase columns designed specifically for separating DNPH derivatives of aldehydes and
ketones. They exhibit superior resolution compared with other commercially available columns.
Aldehydes and ketones are common pollutants in air and water. Several standard methods have been developed to apply using dinitrophenylhydrazine
(DNPH) to various environmental situations to measure these compounds. Some of the better known ones include CARB 1004 for vehicle exhaust, EPA
554 for drinking water, EPA 1667 for pharmaceutical wastewater, and EPA 8315 for general wastewater.
5. Butyraldehyde DNPH
EPA 6. Cyclohexanone DNPH
554 7. Valeraldehyde DNPH
8. Hexanal DNPH
9. Heptanal DNPH
13 14 15 16 17 19 10. Octanal DNPH
CARB 11. Nonanal DNPH
12. Decanal DNPH
1004 13. Acetone DNPH
14. Acrolein DNPH
15. Butanone DNPH
18 20
Thermo Scientific Chromatography Columns and Consumables 2016-2017
19
16. Methacrolein DNPH
EPA 17. Benzaldehyde DNPH
TO-11 18. Isovaleraldehyde DNPH
0 19. Tolualdehyde DNPH
20. Xylylaldehyde DNPH
0 5 10 15 18
Minutes
4-058
LC Columns and Accessories >>
Hypercarb HPLC Columns
100% porous graphitic carbon for extended
separation capabilities
Hypercarb
Used for the retention and separation of highly polar species. Thermo Scientific
Hypercarb columns are ideally suited to solve in both reversed phase and normal
phase HPLCand LC-MS applications.
Exceptional Retention
of Very Polar Analytes
Ideal for complex separations
Separates Structurally
Related Substances
More effective than silica-based columns
pH Stable from 0 to 14
Extended temperature and pressure capabilities
www.thermoscientific.com/chromatography 4-059
Increased Retention of Polar Analytes
LC Columns and Accessories
PS-DVB Hypercarb
Additional retention is achieved for polar compounds using a Hypercarb column compared to a polar endcapped C18.
Note also the change in elution order.
Thermo Scientific Chromatography Columns and Consumables 2016-2017
columns
1 1
4
2
PGCpH12
0 10 20 Min 0 10 20 Min
Hypercarb column stability at pH 12: retention and selectivity do not change even after 93 days of storage in 0.1M NaOH/MeOH
4-060
LC Columns and Accessories >>
Hypercarb
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
3 Drop-in Guard (4/pk) 10 2.1 35003-012101
3.0 35003-013001
4.6 35003-014001
HPLC Column 30 1.0 35003-032130
3.0 35003-033030
50 2.1 35003-052130
3.0 35003-053030
4.6 35003-054630
100 2.1 35003-102130
3.0 35003-103030
4.6 35003-104630
150 2.1 35003-152130
3.0 35003-153030
4.6 35003-154630
High Temperature HPLC Column 30 2.1 35003-032146
50 2.1 35003-052146
4.6 35003-054646
100 2.1 35003-102146
3.0 35003-103046
4.6 35003-104646
5 Drop-in Guard (4/pk) 10 2.1 35005-012101
3.0 35005-013001
Hypercarb
4.6 35005-014001
HPLC Column 30 2.1 35005-032130
3.0 35005-033030
4.6 35005-034630
50 2.1 35005-052130
3.0 35005-053030
4.6 35005-054630
100 2.1 35005-102130
3.0 35005-103030
4.6 35005-104630
150 2.1 35005-152130
3.0 35005-153030
4.6 35005-154630
High Temperature HPLC Column 30 2.1 35005-032146
4.6 35005-034646
50 2.1 35005-052146
4.6 35005-054646
100 2.1 35005-102146
4.6 35005-104646
Javelin HTS Column 20 2.1 35005-022135
Preparative HPLC Column 100 10 35005-109070
21.2 35005-109270
30 35005-109370
150 10 35005-159070
21.2 35005-159270
www.thermoscientific.com/chromatography 4-061
LC Columns and Accessories
Syncronis HPLC
and UHPLC Columns
Consistent Separations
Highly pure, high surface area silica
4-062
Syncronis C18 pH Range
Ziovudine
Syncronis
2400 Syncronis C18, 5m, 150 x 4.6mm
Mobile Phase: Water:Methanol (4:1)
2000 Temperature: 25C
Flow Rate: 1.0mL/min
1600
Injection Volume: 10L
Detection: UV, 265nm
mAU
1200
Analytes: 1. Zidovudine
800
400
0
0 4 8 12 16 20 24 28 32
Minutes
Syncronis C18
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
1.7 UHPLC Column 30 97102-032130 - -
50 97102-052130 - -
100 97102-102130 - -
3 HPLC Column 30 97103-032130 - -
50 97103-052130 - 97103-054630
100 97103-102130 97103-103030 97103-104630
150 97103-152130 - 97103-154630
5 Drop-in Guard (4/pk) 10 97105-012101 97105-013001 97105-014001
HPLC Column 30 97105-032130 - -
50 97105-052130 97105-053030 97105-054630
100 97105-102130 97105-103030 97105-104630
150 97105-152130 97105-153030 97105-154630
250 97105-252130 97105-253030 97105-254630
UNIGUARD Drop-in Guard
10 852-00 852-00 850-00
Cartridge Holder
www.thermoscientific.com/chromatography 4-063
Syncronis C8 pH Range
LC Columns and Accessories
0 100 300
Carbon Load (%)
Highly pure, high surface area silica
Less hydrophobic than Syncronis C18 0 11 25
Double endcapped for extra surface coverage Particle Size 1.7m, 3m, 5m USP L7
Uron herbicides
1000
Syncronis C8, 5m, 150 x 4.6mm
3 Mobile Phase A: Water
800 Mobile Phase B: Acetonitrile
4 Gradient: 35 to 60% B in 10 minutes
2 Temperature: 30C
600 Flow Rate: 1.0mL/min
5 Injection Volume: 20L
mAU
6 Detection: 240nm
400 Analytes: 1. Tebuthiuron
1 2. Metoxuron
3. Monuron
200 4. Chlorotoluron
5. Diuron
6. Linuron
0
0 2 4 6 8 10 12 14 16
Minutes
Syncronis C8
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97202-052130 - -
100 97202-102130 - -
3 HPLC Column 50 97203-052130 - -
100 - 97203-103030 97203-104630
150 - - 97203-154630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-064
Syncronis aQ pH Range
In comparison to a conventionally endcapped C18, the Syncronis aQ polar end-capped C18 stationary
phase exhibits superior stability towards aqueous mobile phase. Syncronis aQ shows no degradation
in performance after 100 injections in a buffered 100% aqueous eluent.
Stability of Syncronis
DAD1 A, Sig=260,4 aQ in 100% aqueous mobile phase
Ref=360,100 (110809B\R2000001.D)
Syncronis
60 Temperature: 30C
Flow Rate: 0.7mL/min
Injection Volume: 2L
mAU
40
Detection: 260nm
Analytes: 1. Cytidine-5-diphosphate
20 2. Adenosine-5-triphosphate
3. Adenosine-5-diphosphate
4. Adenosine-5-monophosphate
0
0DAD1 A, Sig=260,4
1 Ref=360,100
2 (110809B\R2000085.D)
3 4 5 6 7 8
Minutes 100% aqueous inj 2
80
60
mAU
40
20
0 1 2 3 4 5 6 7 8
Minutes 100% aqueous inj 100
Syncronis aQ
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97302-052130 - - 97302-054630
100 97302-102130 97302-103030 - -
3 HPLC Column 50 97303-052130 - - -
100 - 97303-103030 - 97303-104630
150 - - - 97303-154630
5 Drop-in Guard (4/pk) 10 97305-012101 97305-013001 97305-014001 97305-014001
50 97305-052130 97305-053030 - 97305-054630
100 97305-102130 - - 97305-104630
150 97305-152130 97305-153030 97305-154030 97305-154630
250 - 97305-253030 97305-254030 97305-254630
UNIGUARD Drop-in Guard 10 852-00 852-00 850-00 850-00
Cartridge Holder
www.thermoscientific.com/chromatography 4-065
Syncronis Phenyl
LC Columns and Accessories
pH Range
40
20
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Minutes
Syncronis Phenyl
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97902-052130 - -
100 97902-102130 - -
3 HPLC Column 50 97903-052130 - -
100 - - 97903-104630
150 - - 97903-154630
5 Drop-in Guard (4/pk) 10 97905-012101 97905-013001 97905-014001
HPLC Column 50 - 97905-053030 97905-054630
100 - 97905-103030 97905-104630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-066
Syncronis Amino
Lactulose
Syncronis Amino 5m, 150 x 4.6mm
Mobile Phase: Water: MeCN (30:70)
2.00
Temperature: 35C
Flow Rate: 1.0mL/min
1.50 Detection: RI
Injection Volume: 5L
Analytes: 1. Lactulose
uRIU
1.00
0.50
Syncronis
0.00
-0.25
0 1 2 3 4 5 6 7 8 9 10
Minutes
Syncronis Amino
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97702-052130 - - -
100 97702-102130 - - -
3 HPLC Column 50 97703-052130 - - -
5 Drop-in Guard (4/pk) 10 97705-012101 97705-013001 97705-014001 97705-014001
HPLC Column 30 97705-032130 - - -
50 97705-052130 - - 97705-054630
150 97705-152130 97705-153030 97705-154030 97705-154630
250 - 97705-253030 97705-254030 97705-254630
UNIGUARD Drop-in Guard 10 852-00 852-00 850-00 850-00
Cartridge Holder
www.thermoscientific.com/chromatography 4-067
Syncronis Silica pH Range
LC Columns and Accessories
12
Syncronis Silica 5m, 150 x 4.6mm
10 Mobile Phase: Hexane +0.2% propan-2-ol (IPA)
Temperature: 40C
8 Flow Rate: 2.0mL/min
Injection Volume: 10L
Detection: UV, 254nm
mAU
6 Analytes: a-tocopherol
b -tocopherol
g -tocopherol
4 d-tocopherol
0 5 10 15 20 25
Minutes
Syncronis Silica
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97002-052130 - - -
100 97002-102130 - - -
3 HPLC Column 50 97003-052130 - - -
5 Drop-in Guard (4/pk) 10 97005-012101 97005-013001 97005-014001 97005-014001
HPLC Column 50 97005-052130 - - -
100 97005-102130 - - -
150 97005-152130 97005-153030 97005-154030 97005-154630
250 - 97005-253030 97005-254030 97005-254630
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-068
Syncronis HILIC pH Range
Low High
Alternative selectivity to Syncronis C18 Pore Size
Improved sensitivity with MS detection
0 100 300
No need for ion-pair or derivatization
Carbon Load (%)
Outstanding peak shape and sensitivity
0 5 25
Highly pure, high surface area silica particles
Particle Size 1.7m, 3m, 5m
Neutral (uncharged), highly polar surface
Analytes: 1. catechol
2 2. 5-HIAA
200
Syncronis
4 3. DOPAC
3 4. serotonin
100 5. tyrosine
5 6. dopamine
6 7 7. L-DOPA
0
0 5 10 15 20
Minutes
Syncronis HILIC
Particle Size (m) Format Length (mm) 2.1mm ID 3.0mm ID 4.6mm ID
1.7 UHPLC Column 50 97502-052130 - 97502-054630
100 97502-102130 - -
3 HPLC Column 50 97503-052130 - -
100 - - 97503-104630
150 - - 97503-154630
5 Drop-in Guard (4/pk) 10 97505-012101 97505-013001 97505-014001
HPLC Column 50 97505-052130 - 97505-054630
100 97505-102130 - 97505-104630
150 97505-152130 97505-153030 97505-154630
250 - - 97505-254630
UNIGUARD Drop-in Guard 10 852-00 852-00 850-00
Cartridge Holder
www.thermoscientific.com/chromatography 4-069
LC Columns and Accessories
Excellent Reproducibility
Manufactured to the highest standards
4-070
Hypersil BDS
Hypersil BDS
Particle Size (m) Format Length (mm) ID (mm) C18 C8 Phenyl CN
2.4 Drop-in Guard 10 2.1 28102-012101 28202-012101 - -
(4/pk) 4.0/4.6 28102-014001 28202-014001 - -
50 2.1 28102-052130 28202-052130 - -
4.6 28102-054630 - - -
100 2.1 28102-102130 28202-102130 - -
4.6 28102-104630 28202-104630 - -
150 4.6 - 28202-154630 - -
3 Drop-in Guard 10 2.1 28103-012101 28203-012101 - -
(4/pk) 3.0 28103-013001 28203-013001 - -
4.0/4.6 28103-014001 28203-014001 28903-014001 28803-014001
HPLC Column 30 2.1 28103-032130 - - -
50 2.1 28103-052130 28203-052130 - -
3.0 28103-053030 - - -
4.6 28103-054630 28203-054630 - -
100 2.1 28103-102130 - - -
Hypersil BDS
3.0 28103-103030 - - -
4.0 28103-104030 - - -
4.6 28103-104630 28203-104630 - -
150 2.1 28103-152130 - - -
3.0 28103-153030 28203-153030 - -
4.0 28103-154030 - - -
4.6 28103-154630 28203-154630 28903-154630 28803-154630
5 Drop-in Guard 10 2.1 28105-012101 28205-012101 - -
(4/pk) 3.0 28105-013001 28205-013001 - -
4.0/4.6 28105-014001 28205-014001 28905-014001 28805-014001
HPLC Column 50 2.1 28105-052130 28205-052130 - -
3.0 28105-053030 28205-053030 - -
4.6 28105-054630 28205-054630 - -
100 2.1 28105-102130 28205-102130 - -
3.0 28105-103030 - - -
4.0 28105-104030 - - -
4.6 28105-104630 28205-104630 - -
125 3.0 28105-123030 - - -
4.0 28105-124030 - - -
4.6 28105-124630 - - -
150 2.1 28105-152130 - - -
3.0 28105-153030 - - -
4.0 28105-154030 28205-154030 - -
4.6 28105-154630 28205-154630 28905-154630 28805-154630
250 2.1 28105-252130 - - -
3.0 28105-253030 - - -
4.0 28105-254030 28205-254030 28905-254030 -
4.6 28105-254630 28205-254630 28905-254630 28805-254630
www.thermoscientific.com/chromatography 4-071
Hypersil Classical
LC Columns and Accessories
Hypersil ODS
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
3 Drop-in Guard (4/pk) 10 2.1 30103-012101
3.0 30103-013001
4.0/4.6 30103-014001
HPLC Column 50 3.0 30103-053030
4.6 30103-054630
100 2.1 30103-102130
3.0 30103-103030
4.0 30103-104030
4.6 30103-104630
125 4.0 30103-124030
4.6 30103-124630
150 2.1 30103-152130
3.0 30103-153030
4.0 30103-154030
4.6 30103-154630
250 2.1 30103-252130
3.0 30103-253030
4.0 30103-254030
4.6 30103-254630
5 Drop-in Guard (4/pk) 10 2.1 30105-012101
3.0 30105-013001
4.0/4.6 30105-014001
HPLC Column 50 3.0 30105-053030
4.6 30105-054630
100 2.1 30105-102130
3.0 30105-103030
4.0 30105-104030
4.6 30105-104630
125 3.0 30105-123030
4.0 30105-124030
4.6 30105-124630
150 2.1 30105-152130
Thermo Scientific Chromatography Columns and Consumables 2016-2017
3.0 30105-153030
4.0 30105-154030
4.6 30105-154630
200 2.1 30105-202130
4.0 30105-204030
4.6 30105-204630
250 2.1 30105-252130
3.0 30105-253030
4.0 30105-254030
4.6 30105-254630
4-072
LC Columns and Accessories >>
Hypersil ODS-2
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
3 Drop-in Guard (4/pk) 10 4.0/4.6 31603-014001
HPLC Column 50 4.6 31603-054630
100 4.0 31603-104030
4.6 31603-104630
150 4.6 31603-154630
5 Drop-in Guard (4/pk) 10 4.0/4.6 31605-014001
HPLC Column 50 4.6 31605-054630
100 4.6 31605-104630
150 4.6 31605-154630
250 4.0 31605-254030
4.6 31605-254630
Hypersil Classical
250 4.0 30205-254030
4.6 30205-254630
Hypersil Phenyl
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
5 Drop-in Guard (4/pk) 10 4.0/4.6 30905-014001
HPLC Column 50 4.6 30905-054630
150 4.6 30905-154630
250 4.0 30905-254030
4.6 30905-254630
Hypersil Phenyl-2
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
5 Drop-in Guard (4/pk) 10 4.0/4.6 31905-014001
HPLC Column 150 4.6 31905-154630
250 4.6 31905-254630
www.thermoscientific.com/chromatography 4-073
LC Columns and Accessories
Hypersil CPS
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
3 Drop-in Guard (4/pk) 10 4.0/4.6 30803-014001
HPLC Column 150 4.6 30803-154630
5 Drop-in Guard (4/pk) 10 4.0/4.6 30805-014001
HPLC Column 150 4.6 30805-154630
250 4.0 30805-254030
4.6 30805-254630
Hypersil CPS-2
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
5 Drop-in Guard (4/pk) 10 4.6 31805-014001
HPLC Column 150 4.6 31805-254630
250 4.6 31805-254630
Hypersil APS-2
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
3 Drop-in Guard (4/pk) 10 2.1 30703-012101
4.6 30703-014001
HPLC Column 50 4.6 30703-054630
100 2.1 30703-102130
150 2.1 30703-152130
4.6 30703-154630
5 Drop-in Guard (4/pk) 10 3.0 30705-013001
4.0/4.6 30705-014001
HPLC Column 100 3.0 30705-103030
4.6 30705-104630
150 4.6 30705-154630
250 4.0 30705-254030
4.6 30705-254630
Hypersil Silica
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-074
Hypersil Classical continued
Hypersil Classical
3.0 31103-103030
4.6 31103-104630
HPLC Column 150 2.1 31103-152130
4.6 31103-154630
5 Guard Cartridge 10 4.6 31105-014001
HPLC Column 100 4.6 31105-104630
150 4.6 31105-154630
250 4.6 31105-254630
www.thermoscientific.com/chromatography 4-075
IonPac NS1 and NS2
LC Columns and Accessories
Excellent resolution
Good peak shape
Ideal for separation of large molecules that carry localized charges, such as surfactants
Compatible with acids, bases, and solvent from pH 0 to 14
Can also be used for traditional polymeric reversed-phase applications
Utilize ion-pair chromatography for difficult separations
Thermo Scientific IonPac NS1-10m and NS1-5m columns are packed with a neutral, macroporous, high-surface-
area, ethylvinylbenzene polymer crosslinked with 55% divinylbenzene. This resin makes the NS1 resistant
to solvents, acids, and bases, and permits the use of eluent from pH 0 to 14. The Dionex IonPac NS1 column
is the column of choice for routine ion pair chromatography.
IonPac NS2 is a silica-based column for mobile-phase ion chromatography (MPIC) applications using eluents containing
trifluoroacetic acid (TFA), heptafluorobutyric acid (HFBA), or tetrabutylammonium borate (TBAB). It provides high
performance analysis for hydrophobic amines and hydrophobic acids using suppressed conductivity detection.
4-076
HyperREZ XP
HyperREZ XP
Particle Size (m) Format Length (mm) ID (mm) Cat. No.
HyperREZ XP Carbohydrate H+ 8 Guard Cartridge (2/pk) 5 3.0 69008-903027
Guard Column 50 7.7 69008-057726
HPLC Column 300 7.7 69008-307780
HyperREZ XP Carbohydrate Ca2+ 8 Guard Cartridge (2/pk) 5 3.0 69208-903027
Guard Column 50 7.7 69208-057726
HPLC Column 300 7.7 69208-307780
HyperREZ XP Carbohydrate Pb2+ 8 Guard Cartridge (2/pk) 5 3.0 69108-903027
HyperREZ
Guard Column 50 7.7 69108-057726
HPLC Column 300 7.7 69108-307780
HyperREZ XP Carbohydrate Na+ 10 Guard Cartridge (2/pk) 5 3.0 69310-903027
Guard Column 50 7.7 69310-057726
HPLC Column 300 7.7 69310-307780
HyperREZ XP Organic Acids 8 Guard Cartridge (2/pk) 5 3.0 69008-903027
HPLC Column 100 7.7 69608-107780
HyperREZ XP Sugar Alcohols 8 Guard Cartridge (2/pk) 5 3.0 69208-903027
HPLC Column 250 4.0 69708-254080
www.thermoscientific.com/chromatography 4-077
LC Columns and Accessories
LC Accessories
Excellence in LC accessories providing
optimal performance
Thermo Scientific offers a wide range of accessories to suit your LC needs,
ensuring confidence in your analysis and delivery of exceptionally reproducible
data and reliable chromatography.
LC Syringes
Supporting manual and automated injections
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-078
LC Columns and Accessories >>
Viper Fingertight Fittings
Provides ease of use and dead-volume free plumbing of every conventional
HPLC and UHPLC system
www.thermoscientific.com/chromatography 4-079
LC Columns and Accessories
Viper Accessories
Description Cat. No. Quantity
Plug, Biocompatible 6040.2303 1 Each
Union, SST 6040.2304 1 Each
Calibration Tool 6040.2312 1 Each
Inline Filter 6036.1045 1 Each
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-080
Viper Fingertight Fitting Kits for UltiMate 3000 Systems
www.thermoscientific.com/chromatography 4-081
Javelin Direct-Connection Column Filters
LC Columns and Accessories
Replaceable 0.5m drop-in filter enhances column lifetime and improved performance
Holder attached directly to the inlet of your analytical system for maximum convenience
UHPLC Filter
Column protection for Hypersil GOLD 1.9m and Syncronis 1.7m columns
without compromising performance
UHPLC Filter
Description Cat. No. Quantity
UHPLC Direct Connect Filter Holder 27006 1 Each
2.1mm ID Replacement Filter Cartridge, 0.2m 22180 5 Pack
1.0mm ID Replacement Filter Cartridge, 0.2m 22185 5 Pack
4-082
PTFE One-Piece Column Connector
Fingertight, leak-free connection of analytical and guard columns with 10-32 threads
Minimizes dead volume
Inert and biocompatible material
Solvent Filters
HPLC Filters
Efficient draw
Solvent Filters
Type For Use with Cat. No. Quantity
Stainless Steel Fit 1/16in OD tube to 1/8in OD plastic tubing A-302 1 Each
Stainless Steel Fit to 1/8in OD plastic tubing using 1/8in PP nut A-302A 1 Each
www.thermoscientific.com/chromatography 4-083
PEEKsil Capillary Tubing
LC Columns and Accessories
4-084
316 Stainless Steel Capillary Tubing
LC Tubing
0.007 5 Black 1 Each
10 Black U-127 1 Each
20 Black U-128 1 Each
30 Black U-129 1 Each
50 Black U-130 1 Each
100 Black U-131 1 Each
0.010 5 Blue U-111 1 Each
10 Blue U-112 1 Each
20 Blue U-113 1 Each
30 Blue U-114 1 Each
50 Blue U-132 1 Each
100 Blue U-133 1 Each
1/32in OD Precut Tubing with 1/16in Sleeves
0.005 10.5 Red 30011-FLEX 1 Each
15 Red 30015-FLEX 1 Each
28 Red 30028-FLEX 1 Each
40 Red 30040-FLEX 1 Each
0.007 10.5 Yellow 39011-FLEX 1 Each
15 Yellow 39015-FLEX 1 Each
28 Yellow 39028-FLEX 1 Each
40 Yellow 39040-FLEX 1 Each
www.thermoscientific.com/chromatography 4-085
PEEK Capillary Tubing
LC Columns and Accessories
4-086
High Pressure Stainless Steel Nuts and Ferrules
LC Fittings
Reducing Union for Preparative Columns
Connects 30 to 50mm ID preparative columns to 1/16in tubing
Resist cracking, breaking, thread stripping and leaking in both low and high pressure applications
Biocompatible for a broad range of applications
Column End Plug, 1/16in, 10-32 coned, Delrin, Red U-467R 1 Each
Column End Plug, 1/16in, 10-32 coned, Delrin, Black U-467BLK 1 Each
www.thermoscientific.com/chromatography 4-087
Stainless Steel Unions, Tees and Crosses
LC Columns and Accessories
Union, PEEK polymer, includes two PEEK 2-piece fittings 0.010 0.070 P-742 1 Each
Union, PEEK polymer, includes two PEEK 2-piece fittings 0.020 0.28 P-704 1 Each
4-088
Rheodyne 7725 and 7725i Sample Injectors
LC Injectors
Description Volume ID (mm / in) Cat. No. Quantity
Sample loops for 5L 0.18 / 0.007 7755-020 1 Each
7725 and 7725i 10L 0.30 / 0.012 7755-021 1 Each
injectors
20L 0.30 / 0.012 7755-022 1 Each
50L 0.51 / 0.020 7755-023 1 Each
RheBuild Kits
For Use with Rheodyne Models Cat. No. Quantity
7725/7725i 7725-999 1 Each
Rheodyne Stators
For Use with Rheodyne Models Cat. No. Quantity
7725 7725-010 1 Each
www.thermoscientific.com/chromatography 4-089
Rheodyne 9725 and 9725i Sample Injectors
LC Columns and Accessories
Allow continuous flow between the load and inject positions to protect against
pressure shock
4-090
Rheodyne 8125 Low-Dispersion Microscale Injector
Can use partial filling for zero sample waste or complete filling for better reproducibility
Position sensing switch provides reproducible start signal
Suitable for use with 5 to 50L sample loops
LC Injectors
RheBuild Kits
For Use with Rheodyne Models Cat. No. Quantity
8125 8125-999 1 Each
Rheodyne Stators
For Use with Rheodyne Models Cat. No. Quantity
8125/8126 8125-098 1 Each
www.thermoscientific.com/chromatography 4-091
Rheodyne 7010 Sample Injector
LC Columns and Accessories
RheBuild Kits
For Use with Rheodyne Models Cat. No. Quantity
7010/7000 7010-999 1 Each
4-092
Rheodyne 9010 Sample Injector
LC Injectors
Description Volume ID (mm / in) Cat. No. Quantity
Sample loops for 2L Internal 7755-015 1 Each
9010 injectors 5L 0.18 / 0.007 9055-020 1 Each
10L 0.25 / 0.010 9055-021 1 Each
20L 0.25 / 0.010 9055-022 1 Each
50L 0.51 / 0.020 9055-023 1 Each
100L 0.51 / 0.020 9055-024 1 Each
200L 0.51 / 0.020 9055-025 1 Each
500L 0.76 / 0.030 9055-026 1 Each
1mL 0.76 / 0.030 9055-027 1 Each
5mL 0.76 / 0.030 9055-029 1 Each
Rheodyne Stators
For Use with Rheodyne Models Cat. No. Quantity
9010 9125-043 1 Each
www.thermoscientific.com/chromatography 4-093
RheFlex High Pressure Fittings
LC Columns and Accessories
Slotted backside of the ferrule is squeezed down onto the tube by the
mating conical surface of the nut
May be used on 1/16in metal or plastic tubing reliably up to 5000psi
Reusable ferrule and nut
4-094
Cheminert Model C2 Microbore Injector
1/16in fittings
0.010in ports
Available in 6-port or 10-port configurations
Available with manual or microelectric actuator
LC Injectors
100L CSL100 1 Each
Model C4 injector, PAEK stator, 5L loop,
6 ports C2-1346EH 1 Each
microelectric actuator
Sample injector loops, PAEK 5L CZSL5PK 1 Each
10L CZSL10PK 1 Each
50L CZSL50PK 1 Each
Valco Accessories
Description Volume Cat. No. Quantity
Valco syringe ports 22 ga. needles; 1/16in fittings VISF-1 1 Each
Valco syringe ports 22 ga. 2in needles VISF-2 1 Each
Valco Nuts and Ferrules 1/16in standard nut ZN1-10 10 Pack
Valco Nuts and Ferrules 1/16in long nut LZN1-10 10 Pack
Valco Nuts and Ferrules 1/16in SS ferrule ZF1-10 10 Pack
www.thermoscientific.com/chromatography 4-095
LC Syringes for Manual Injection valves
LC Columns and Accessories
4-096
HPLC Syringes
LC Syringes
LCQ XSQ 365RNLT3 1 Each
www.thermoscientific.com/chromatography 4-097
HOT POCKET and COOL POCKET Column Temperature Controllers
LC Columns and Accessories
Product Specifications
HOT POCKET COOL POCKET
Operating Range 5C above ambient to 85C 5C to 55C
Display Dual LED displays of actual and set point temperatures in C
Temperature Accuracy 2C over entire range 2C over entire range
Temperature Repeatability 1C 1C
Temperature Stability 0.1C 0.1C
Time to Stabilization (from ambient) 85C in less than 30 minutes 55C in 25 minutes, 5C in 20 minutes
80C 80C
Thermo Scientific Chromatography Columns and Consumables 2016-2017
oven4 oven3
0 1 2 3 4 5 MIN 0 1 2 3 4 5 MIN
HOT POCKET Column Heaters, Eluent Preheater/Precooler and COOL POCKET Chiller
Description Cat. No. Quantity
HOT POCKET Column Heater 92016 1 Each
HOT POCKET Column Heater short version 92016-150 1 Each
COOL POCKET Column Chiller 92017 1 Each
Eluent Preheater/Precooler 92018 1 Each
4-098
H2N
O OH
-O O -O
N+
O- -O O
N+ N+
N+ O NH2
O O O
S
OH O
OH O
H2N O
O- OH
S -O
N+ N+
NH2
H2N
N+ N+ H
N
-O O
OH NH2
O-
O O -O
N+ N+
N+ NH2 O
H
N
O O OH
-O O-
NH2
N+ N+
O O
-O O
N+ O
H
N
OH
LC Reagents -O
N+ N+
O-
NH2
O O
LC Reagents
Control selectivity, resolve complex ionic mixtures and improve peak symmetry
with the use of our LC reagents.
www.thermoscientific.com/chromatography 4-099
LC Reagents
LC Columns and Accessories
Technical Resources
O
O OH
O S O O
N N
+ +
N N TNBSA N S O
O O MW 293.17 Cl
+
N
O O
O
OH
Ninhydrin
MW 178.14
OH
visit www.thermoscientific.com/chromexpert
to access the following information:
Thermo Scientific Chromatography Columns and Consumables 2016-2017
www.
thermoscientific.com/chromexpert
www.
thermoscientific.com
/chromexpert
www.
thermoscientific.com
/chromexpert
4-100
HPLC Ion Pair Reagents
Heptafluorobutyric Acid
Description Quantity Cat. No. Quantity
Heptafluorobutyric Acid, Sequencing Grade 100mL X TS-25003 1 Each
Heptafluorobutyric Acid, HPLC Grade 10 x 1mL ampules TS-53104 1 Pack
X in the ordering table indicates that hazardous shipping charges apply.
LC Reagents
Triethylamine (TEA) 2(a);0.000M TEA 2(b);0.010M TEA 2(c);0.020M TEA
2,4-dimethylaniline
Triethylamine is an ion-pairing reagent that alters selectivity in reversed-phase
2,4-dimethylaniline
HPLC separations. By pairing with peptides, it effectively sharpens peaks, resulting
2,4-dimethylaniline
Molecular formula CH N
2,4-dimethylaniline
6 15
Molecular weight 101.19
2,4-dimethylaniline
Density 0.726g/mL
www.thermoscientific.com/chromatography 4-101
Formic Acid Ampules
LC Columns and Accessories
Formic acid is a component found in reverse-phase mobile phases to provide protons for
LC-MS analysis. The presence of a low concentration of formic acid in the mobile phase
is also know to improve the peak shapes of the resulting separation. Unlike trifluoroacetic
acid (TFA), formic acid is not an ion-pairing reagent, and it does not suppress MS ionization
of polypeptides when used as a mobile phase component.
Prescored, nitrogen-flushed, amber glass to protect formic acid from light and moisture
99% purity for consistent LC baselines and no interference introduced into LC and mass
spectrometry applications
Convenient format simplifies preparation of gradient and isocratic mobile phases containing
0.1% (v/v) formic acid in water or acetonitrile
Contents of a single vial in a final volume of 1L solvent yields a mobile phase of the most
common formic acid concentration
For complex peptide separations, the key to success can be to vary selectivity. Varying mobile phase
composition on the same column can change selectivity enough to resolve peptides that would otherwise
overlap. The TFA concentration is usually specified as 0.1% for reverse-phase HPLC of peptides. For
reproducible separations from run-to-run or from lab-to-lab, it is essential to make concentrations the same.
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-102
Derivatization and Visualization Reagents for HPLC
Purity: >99.5% TFA and exceptional clarity allows sensitive, non-destructive peptide
detection at low UV wavelengths
High-performance packaging: Packaged under nitrogen in amber glass with protective TFE-lined
fluorocarbon caps to ensure TFA integrity
Choice of formats for convenience: 1mL ampules can prepare 1L of 0.1% v/v TFA solution for
the mobile phase in reversed-phase chromatography in moments
LC Reagents
X in the ordering table indicates that hazardous shipping charges apply.
D-Phenyalanine
D-Alanine
D-Aspartic Acid
L-Glutamic Acid
L-Phenylalanine
D-Methionine
Absorbance @ 340 nm
L-Alanine
L-Aspartic Acid
10 20 30 40
www.thermoscientific.com/chromatography 4-103
p-Bromophenacylate Reagent
LC Columns and Accessories
p-Bromophenacylate Reagent
Description Quantity Cat. No. Quantity
p-Bromophenacylate Reagent 10mL TS-48891 1 Each
Couples with primary amines, sulfhydryls and hydrazides in aqueous solution at pH 8, without
undesirable side reactions
Excellent for solution or solid phase analysis
Suitable for qualitative and quantitative estimation of biomolecules; including amino acids,
eptides or proteins
Chromogenic, O = 335nm
max
Colored derivatives are monitored at 345nm and have extinction coefficients in range of 1-1.5 x 104
TNBSA
Thermo Scientific Chromatography Columns and Consumables 2016-2017
4-104
Hydrolysis Reagents
LC Reagents
Uses L-form configuration to permit standardization of microbial and other assays
Molar concentration verified by conventional amino acid analysis methods
With the exception of cystine, each amino acid is supplied at a concentration
of 2.5moles/mL in 0.1N HCl
The following amino acids are included in Amino Acid Standard H:
L-Alanine, Ammonia [(NH4)2SO4], L-Arginine, L-Aspartic Acid, L-Cystine, L-Glutamic Acid,
Glycine, L-Histidine, L-Isoleucine, L-Leucine, L-LysineHCl, L-Methionine,
L-Phenylalanine, L-Proline, L-Serine, L-Threonine, L-Tyrosine, L-Valine.
www.thermoscientific.com/chromatography 4-105
Amino Acid Detection Reagents
LC Columns and Accessories
Ninhydrin
The reagent of choice for detection of amino acids
Ninhydrin
Description Quantity Cat. No. Quantity
Ninhydrin 500g TS-21003 1 Each
Indefinitely stable. No refrigeration required. Keep bottle tightly sealed. Avoid exposure to direct sunlight and
ammonia.
Distilled in glass, filtered through 0.2m TFE membranes and packed in solvent-rinsed,
amber glass bottles
TFE-lined screw caps seal bottles
Acetonitrile, HPLC Grade, Physical Dimethylformamide (DMF), Sequencing Dimethylsulfoxide (DMSO), Sequencing
Properties Grade, Physical Properties Grade, Physical Properties
UV Cutoff: 190nm HCON(CH3)2 C2H6OS
Optical Absorbance: <0.02 at 220nm Purity (GC): 99% Purity (GC): >99.5%
Refractive Index at 25C: 1.342 MW: 73.09 MW: 78.13
4-106
High-Purity Pre-Column Derivatization Reagents
PITC (Phenylisothiocyanate)
Description Quantity Cat. No. Quantity
PITC (Edmans Reagent) 10 1mL TS-26922 1 Pack
LC Reagents
www.thermoscientific.com/chromatography 4-107
Peptide Standards
LC Columns and Accessories
Evaluate reverse-phase supports of varying n-alkyl chain lengths and ligand densities
Retention times are predicted by totaling the values that represent the contribution in minutes of each
amino acid residue and the peptide terminal groups. Retention time is dependent upon the molecular
weight of the peptide. The effect on retention is relatively unimportant with a small peptide, but it
increases with the size of the molecule. The accuracy of predicting peptide retention time significantly
decreases beyond 20 residues. To ensure accuracy, a peptide standard is used to correct for instrument
variation, column aging, n-alkyl chain length variation and ligand density.
4-108
LC and LC-MS Instruments
www.thermoscientific.com/chromatography 4-109
LC Columns and Accessories
x2 Dual LC Systems
UltiMate 3000 x2 Dual LC Systems are the ideal choice to maximize sample throughput of conventional
HPLC and UHPLC separations by combining the flexibility of ternary solvent selection with the productivity
and performance of x2 Dual technology.
Operate conventional or high speed applications, increase sample throughput, achieve higher
chromatographic resolution, or automate tedious sample preparation steps such as analyte enrichment
or matrix elimination.
Visit www.thermoscientific.com
4-110
Thermo Scientific LC-MS Systems
Orbitrap LC-MS technology routinely delivers the superior mass resolution and mass accuracy necessary
to reduce analysis times and increase confidence in results. This makes it the platform of choice for the
most confident protein and metabolite identification, characterization and quantitation. Combined with
superior dynamic range and unsurpassed sensitivity, Orbitrap systems are the only mass spectrometers
capable of providing all four benefits at the same time, without compromise.
With market and technology leadership for over 25 years, we offer ion trap LC-MS systems for every
application and budget. Ion trap LC-MS systems offer unique capabilities such as MSn and data-
dependent analysis along with excellent full-scan sensitivity to provide routine detection and
rapid identification of low-level analytes. Ion trap systems support a variety of applications from
compound identification and routine HPLC detection through the most demanding analyses of
low-level components in complex biological matrices.
TSQ Series triple-stage quadrupole LC-MS systems offer a wide range of capabilities. From the
value-conscious Thermo Scientific TSQ Endura LC-MS to the precise Thermo Scientific TSQ Quantiva
LC-MS, our mass spectrometers couple perfectly with our HPLC, UHPLC, and nano-LCs to easily
accommodate complex matrices encountered in a variety of applications.
Visit www.thermoscientific.com/tsq
The system can be used with both HPLC and IC systems in a wide range of applications
and methodologies.
Visit www.thermoscientific.com
www.thermoscientific.com/chromatography 4-111
Terms and Conditions of Sale
Terms and Conditions
UNLESS OTHERWISE EXPRESSLY AGREED IN WRITING, ALL SALES ARE SUBJECT TO THE FOLLOWING TERMS premises under this Agreement and (ii) claims that a Product infringes any valid United States patent, copyright
AND CONDITIONS: or trade secret; provided, however, Seller shall have no liability under this Section to the extent any such
1. GENERAL. Thermo Fisher Scientific (Seller) hereby offers for sale to the buyer named on the face hereof Indemnified Items are caused by either (i) the negligence or willful misconduct of Buyer, its employees, agents or
(Buyer) the products listed on the face hereof (the Products) on the express condition that Buyer agrees to representatives or contractors, (ii) by any third party, (iii) use of a Product in combination with equipment or
accept and be bound by the terms and conditions set forth herein. Any provisions contained in any document software not supplied by Seller where the Product would not itself be infringing, (iv) compliance with Buyers
issued by Buyer are expressly rejected and if the terms and conditions in this Agreement differ from the terms of designs, specifications or instructions, (v) use of the Product in an application or environment for which it was not
Buyers offer, this document shall be construed as a counter offer and shall not be effective as an acceptance of designed or (vi) modifications of the Product by anyone other than Seller without Sellers prior written approval.
Buyers document. Buyers receipt of Products or Sellers commencement of the services provided hereunder Buyer shall provide Seller prompt written notice of any third party claim covered by Sellers indemnification
will constitute Buyers acceptance of this Agreement. This is the complete and exclusive statement of the obligations hereunder. Seller shall have the right to assume exclusive control of the defense of such claim or, at
contract between Seller and Buyer with respect to Buyers purchase of the Products. No waiver, consent, the option of the Seller, to settle the same. Buyer agrees to cooperate reasonably with Seller in connection with
modification, amendment or change of the terms contained herein shall be binding unless in writing and signed the performance by Seller of its obligations in this Section.
by Seller and Buyer. Sellers failure to object to terms contained in any subsequent communication from Buyer Notwithstanding the above, Sellers infringement related indemnification obligations shall be extinguished and
will not be a waiver or modification of the terms set forth herein. All orders are subject to acceptance in writing relieved if Seller, at its discretion and at its own expense (a) procures for Buyer the right, at no additional
by an authorized representative of Seller. expense to Buyer, to continue using the Product; (b) replaces or modifies the Product so that it becomes
2. PRICE. All prices published by Seller or quoted by Sellers representatives may be changed at any time non-infringing, provided the modification or replacement does not adversely affect the specifications of the
without notice. All prices quoted by Seller or Sellers representatives are valid for thirty (30) days, unless Product; or (c) in the event (a) and (b) are not practical, refund to Buyer the amortized amounts paid by Buyer with
otherwise stated in writing. All prices for the Products will be as specified by Seller or, if no price has been respect thereto, based on a five (5) year amortization schedule. THE FOREGOING INDEMNIFICATION PROVISION
specified or quoted, will be Sellers price in effect at the time of shipment. All prices are subject to adjustment STATES SELLERS ENTIRE LIABILITY TO BUYER FOR THE CLAIMS DESCRIBED HEREIN.
on account of specifications, quantities, raw materials, cost of production, shipment arrangements or other 8.2 By Buyer. Buyer shall indemnify, defend with competent and experienced counsel and hold harmless
terms or conditions which are not part of Sellers original price quotation. Seller, its parent, subsidiaries, affiliates and divisions, and their respective officers, directors, shareholders and
3. TAXES AND OTHER CHARGES. Prices for the Products exclude all sales, value added and other taxes and employees, from and against any and all damages, liabilities, actions, causes of action, suits, claims, demands,
duties imposed with respect to the sale, delivery, or use of any Products covered hereby, all of which taxes and losses, costs and expenses (including without limitation reasonable attorneys fees and disbursements and court
duties must by paid by Buyer. If Buyer claims any exemption, Buyer must provide a valid, signed certificate or costs) to the extent arising from or in connection with (i) the negligence or willful misconduct of Buyer, its agents,
letter of exemption for each respective jurisdiction. employees, representatives or contractors; (ii) use of a Product in combination with equipment or software not
4. TERMS OF PAYMENT. Seller may invoice Buyer upon shipment for the price and all other charges payable by supplied by Seller where the Product itself would not be infringing; (iii) Sellers compliance with designs,
Buyer in accordance with the terms on the face hereof. If no payment terms are stated on the face hereof, specifications or instructions supplied to Seller by Buyer; (iv) use of a Product in an application or environment for
payment shall be net thirty (30) days from the date of invoice. If Buyer fails to pay any amounts when due, Buyer which it was not designed; or (v) modifications of a Product by anyone other than Seller without Sellers prior
shall pay Seller interest thereon at a periodic rate of one and one-half percent (1.5%) per month (or, if lower, the written approval.
highest rate permitted by law), together with all costs and expenses (including without limitation reasonable 9. SOFTWARE. With respect to any software products incorporated in or forming a part of the Products
attorneys fees and disbursements and court costs) incurred by Seller in collecting such overdue amounts or hereunder, Seller and Buyer intend and agree that such software products are being licensed and not sold, and
otherwise enforcing Sellers rights hereunder. Seller reserves the right to require from Buyer full or partial that the words purchase, sell or similar or derivative words are understood and agreed to mean license,
payment in advance, or other security that is satisfactory to Seller, at any time that Seller believes in good faith and that the word Buyer or similar or derivative words are understood and agreed to mean licensee.
that Buyers financial condition does not justify the terms of payment specified. All payments shall be made in Notwithstanding anything to the contrary contained herein, Seller or its licensor, as the case may be, retains all
U.S. Dollars. rights and interest in software products provided hereunder.
5. DELIVERY; CANCELLATION OR CHANGES BY BUYER. The Products will be shipped to the destination Seller hereby grants to Buyer a royalty-free, non-exclusive, nontransferable license, without power to
specified by Buyer, F.O.B. Sellers shipping point. Seller will have the right, at its election, to make partial sublicense, to use software provided hereunder solely for Buyers own internal business purposes on the
shipments of the Products and to invoice each shipment separately. Seller reserves the right to stop delivery of hardware products provided hereunder and to use the related documentation solely for Buyers own internal
Products in transit and to withhold shipments in whole or in part if Buyer fails to make any payment to Seller business purposes. This license terminates when Buyers lawful possession of the hardware products provided
when due or otherwise fails to perform its obligations hereunder. All shipping dates are approximate only, and hereunder ceases, unless earlier terminated as provided herein. Buyer agrees to hold in confidence and not to
Seller will not be liable for any loss or damage resulting from any delay in delivery or failure to deliver which is sell, transfer, license, loan or otherwise make available in any form to third parties the software products and
due to any cause beyond Sellers reasonable control. In the event of a delay due to any cause beyond Sellers related documentation provided hereunder. Buyer may not disassemble, decompile or reverse engineer, copy,
reasonable control, Seller reserves the right to terminate the order or to reschedule the shipment within a modify, enhance or otherwise change or supplement the software products provided hereunder without Sellers
reasonable period of time, and Buyer will not be entitled to refuse delivery or otherwise be relieved of any prior written consent. Seller will be entitled to terminate this license if Buyer fails to comply with any term or
obligations as the result of such delay. Products as to which delivery is delayed due to any cause within Buyers condition herein. Buyer agrees, upon termination of this license, immediately to return to Seller all software
control may be placed in storage by Seller at Buyers risk and expense and for Buyers account. Orders in process products and related documentation provided hereunder and all copies and portions thereof.
may be canceled only with Sellers written consent and upon payment of Sellers cancellation charges. Orders in Certain of the software products provided by Seller may be owned by one or more third parties and licensed to
process may not be changed except with Sellers written consent and upon agreement by the parties as to an Seller. Accordingly, Seller and Buyer agree that such third parties retain ownership of and title to such software
appropriate adjustment in the purchase price therefor. Credit will not be allowed for Products returned without products. The warranty and indemnification provisions set forth herein shall not apply to software products
the prior written consent of Seller. owned by third parties and provided hereunder.
6. TITLE AND RISK OF LOSS. Notwithstanding the trade terms indicated above and subject to Sellers right to 10. LIMITATION OF LIABILITY. NOTWITHSTANDING ANYTHING TO THE CONTRARY CONTAINED HEREIN,
stop delivery of Products in transit, title to and risk of loss of the Products will pass to Buyer upon delivery of THE LIABILITY OF SELLER UNDER THESE TERMS AND CONDITIONS (WHETHER BY REASON OF BREACH OF
possession of the Products by Seller to the carrier; provided, however, that title to any software incorporated CONTRACT, TORT, INDEMNIFICATION, OR OTHERWISE, BUT EXCLUDING LIABILITY OF SELLER FOR BREACH
within or forming a part of the Products shall at all times remain with Seller or the licensor(s) thereof, as the case OF WARRANTY (THE SOLE REMEDY FOR WHICH SHALL BE AS PROVIDED UNDER SECTION 7 ABOVE)) SHALL
may be. NOT EXCEED AN AMOUNT EQUAL TO THE LESSER OF (A) THE TOTAL PURCHASE PRICE THERETOFORE PAID BY
7. WARRANTY. Seller warrants that the Products will operate or perform substantially in conformance with BUYER TO SELLER WITH RESPECT TO THE PRODUCT(S) GIVING RISE TO SUCH LIABILITY OR (B) ONE MILLION
Sellers published specifications and be free from defects in material and workmanship, when subjected to DOLLARS ($1,000,000). NOTWITHSTANDING ANYTHING TO THE CONTRARY CONTAINED HEREIN, IN NO
normal, proper and intended usage by properly trained personnel, for the period of time set forth in the product EVENT SHALL SELLER BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES
documentation, published specifications or package inserts. If a period of time is not specified in Sellers product (INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF USE OF FACILITIES OR EQUIPMENT, LOSS OF
documentation, published specifications or package inserts, the warranty period shall be one (1) year from the REVENUE, LOSS OF DATA, LOSS OF PROFITS OR LOSS OF GOODWILL), REGARDLESS OF WHETHER SELLER (a)
date of shipment to Buyer for equipment and ninety (90) days for all other products (the Warranty Period). HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH DAMAGES OR (b) IS NEGLIGENT.
Seller agrees during the Warranty Period, to repair or replace, at Sellers option, defective Products so as to 11. EXPORT RESTRICTIONS Buyer acknowledges that each Product and any related software and technology,
cause the same to operate in substantial conformance with said published specifications; provided that Buyer including technical information supplied by Seller or contained in documents (collectively Items), is subject to
shall (a) promptly notify Seller in writing upon the discovery of any defect, which notice shall include the product export controls of the U.S. government. The export controls may include, but are not limited to, those of the
model and serial number (if applicable) and details of the warranty claim; and (b) after Sellers review, Seller will Export Administration Regulations of the U.S. Department of Commerce (the EAR), which may restrict or
provide Buyer with service data and/or a Return Material Authorization (RMA), which may include biohazard require licenses for the export of Items from the United States and their re-export from other countries. Buyer
decontamination procedures and other product-specific handling instructions, then, if applicable, Buyer may shall comply with the EAR and all other applicable laws, regulations, laws, treaties, and agreements relating to
Thermo Scientific Chromatography Columns and Consumables 2016-2017
return the defective Products to Seller with all costs prepaid by Buyer. Replacement parts may be new or the export, re-export, and import of any Item. Buyer shall not, without first obtaining the required license to do
refurbished, at the election of Seller. All replaced parts shall become the property of Seller. Shipment to Buyer so from the appropriate U.S. government agency; (i) export or re-export any Item, or (ii) export, re-export,
of repaired or replacement Products shall be made in accordance with the Delivery provisions of the Sellers distribute or supply any Item to any restricted or embargoed country or to a person or entity whose privilege to
Terms and Conditions of Sale. Consumables are expressly excluded from this warranty. participate in exports has been denied or restricted by the U.S. government. Buyer shall, if requested by Seller,
Notwithstanding the foregoing, Products supplied by Seller that are obtained by Seller from an original provide information on the end user and end use of any Item exported by the Buyer or to be exported by the
manufacturer or third party supplier are not warranted by Seller, but Seller agrees to assign to Buyer any Buyer. Buyer shall cooperate fully with Seller in any official or unofficial audit or inspection related to applicable
warranty rights in such Product that Seller may have from the original manufacturer or third party supplier, to the export or import control laws or regulations, and shall indemnify and hold Seller harmless from, or in connection
extent such assignment is allowed by such original manufacturer or third party supplier. with, any violation of this Section by Buyer or its employees, consultants, or agents.
In no event shall Seller have any obligation to make repairs, replacements or corrections required, in whole or in 12. MISCELLANEOUS. (a) Buyer may not delegate any duties nor assign any rights or claims hereunder without
part, as the result of (i) normal wear and tear, (ii) accident, disaster or event of force majeure, (iii) misuse, fault or Sellers prior written consent, and any such attempted delegation or assignment shall be void. (b) The rights and
negligence of or by Buyer, (iv) use of the Products in a manner for which they were not designed, (v) causes obligations of the parties hereunder shall be governed by and construed in accordance with the laws of the State
external to the Products such as, but not limited to, power failure or electrical power surges, (vi) improper of Sellers manufacturing location, without reference to its choice of law provisions. Each party hereby
storage and handling of the Products or (vii) use of the Products in combination with equipment or software not irrevocably consents to the exclusive jurisdiction of the state and federal courts located in the county and state
supplied by Seller. If Seller determines that Products for which Buyer has requested warranty services are not of Sellers manufacturing location, in any action arising out of or relating to this Agreement and waives any other
covered by the warranty hereunder, Buyer shall pay or reimburse Seller for all costs of investigating and venue to which it may be entitled by domicile or otherwise. (c) In the event of any legal proceeding between the
responding to such request at Sellers then prevailing time and materials rates. If Seller provides repair services Seller and Buyer relating to this Agreement, neither party may claim the right to a trial by jury, and both parties
or replacement parts that are not covered by this warranty, Buyer shall pay Seller therefor at Sellers then waive any right they may have under applicable law or otherwise to a right to a trial by jury. Any action arising
prevailing time and materials rates. ANY INSTALLATION, MAINTENANCE, REPAIR, SERVICE, RELOCATION OR under this Agreement must be brought within one (1) year from the date that the cause of action arose. (d) The
ALTERATION TO OR OF, OR OTHER TAMPERING WITH, THE PRODUCTS PERFORMED BY ANY PERSON OR application to this Agreement of the U.N. Convention on Contracts for the International Sale of Goods is hereby
ENTITY OTHER THAN SELLER WITHOUT SELLERS PRIOR WRITTEN APPROVAL, OR ANY USE OF expressly excluded. (e) In the event that any one or more provisions contained herein shall be held by a court of
REPLACEMENT PARTS NOT SUPPLIED BY SELLER, SHALL IMMEDIATELY VOID AND CANCEL ALL competent jurisdiction to be invalid, illegal or unenforceable in any respect, the validity, legality and
WARRANTIES WITH RESPECT TO THE AFFECTED PRODUCTS. enforceability of the remaining provisions contained herein shall remain in full force and effect, unless the
THE OBLIGATIONS CREATED BY THIS WARRANTY STATEMENT TO REPAIR OR REPLACE A DEFECTIVE revision materially changes the bargain. (f) Sellers failure to enforce, or Sellers waiver of a breach of, any
PRODUCT SHALL BE THE SOLE REMEDY OF BUYER IN THE EVENT OF A DEFECTIVE PRODUCT. EXCEPT AS provision contained herein shall not constitute a waiver of any other breach or of such provision. (g) Unless
EXPRESSLY PROVIDED IN THIS WARRANTY STATEMENT, SELLER DISCLAIMS ALL OTHER WARRANTIES, otherwise expressly stated on the Product or in the documentation accompanying the Product, the Product is
WHETHER EXPRESS OR IMPLIED, ORAL OR WRITTEN, WITH RESPECT TO THE PRODUCTS, INCLUDING intended for research only and is not to be used for any other purpose, including without limitation, unauthorized
WITHOUT LIMITATION ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses, or any type of consumption by or
PURPOSE. SELLER DOES NOT WARRANT THAT THE PRODUCTS ARE ERROR-FREE OR WILL ACCOMPLISH ANY application to humans or animals. (h) Buyer agrees that all pricing, discounts and technical information that
PARTICULAR RESULT. Seller provides to Buyer are the confidential and proprietary information of Seller. Buyer agrees to (1) keep such
information confidential and not disclose such information to any third party, and (2) use such information solely
8. INDEMNIFICATION.
for Buyers internal purposes and in connection with the Products supplied hereunder. Nothing herein shall
8.1 By Seller. Seller agrees to indemnify, defend and save Buyer, its officer, directors, and employees from and restrict the use of information available to the general public. (i) Any notice or communication required or
against any and all damages, liabilities, actions, causes of action, suits, claims, demands, losses, costs and permitted hereunder shall be in writing and shall be deemed received when personally delivered or three (3)
expenses (including without limitation reasonable attorneys fees) (Indemnified Items) for (i) injury to or death business days after being sent by certified mail, postage prepaid, to a party at the address specified herein or at
of persons or damage to property to the extent caused by the negligence or willful misconduct of Seller, its such other address as either party may from time to time designate to the other.
employees, agents or representatives or contractors in connection with the performance of services at Buyers
6-032
Resources
for Chromatographers
Chromatography Resource Center
Our web-based resource center provides technical support, applications,
technical tips and literature to help move your separations forward.
Visit www.thermoscientific.com/chromatography
BR21443-EN 0116S