Sew Movitrac 07 Manual
Sew Movitrac 07 Manual
Sew Movitrac 07 Manual
MOVITRAC 07 GA320000
Edition 07/2004
11299126 / EN Operating Instructions
SEW-EURODRIVE Driving the world
1 Important Notes................................................................................................. 4
2 Safety Notes ...................................................................................................... 6
3 Unit Design ........................................................................................................ 7
3.1 Unit design ............................................................................................... 7
3.2 Unit designation and scope of delivery ................................................... 11
4 Installation ....................................................................................................... 13
4.1 Installation notes ..................................................................................... 13
4.2 UL compliant installation ......................................................................... 18
4.3 Power shield clamp................................................................................. 19
4.4 Touch guard............................................................................................ 20
4.5 Wiring diagram 230 V 0.37 ... 2.2 kW / 400 V 0.55 ... 4.0 kW................. 21
4.6 Wiring diagram 230 V 3.7 ... 30 kW / 400 V 5.5 ... 45 kW....................... 22
4.7 Terminal assignment / Connection of the brake rectifier......................... 23
4.8 System bus (SBus) installation ............................................................... 24
5 Startup.............................................................................................................. 25
5.1 General startup instructions .................................................................... 25
5.2 Preliminary work and resources.............................................................. 25
5.3 Integrated operating panel ...................................................................... 26
5.4 Principles of operation with the integrated operating panel .................... 27
5.5 Manual Manual speed control module and external setpoint selection .. 29
5.6 Startup using the integrated operating panel .......................................... 32
5.7 Starting the motor ................................................................................... 34
5.8 Loading a LOGODrive program .............................................................. 35
5.9 Parameter list.......................................................................................... 36
6 Operation and Service .................................................................................... 44
6.1 Fault information ..................................................................................... 44
6.2 List of faults (F-00 ... F-97)...................................................................... 46
6.3 List of warnings (r-17 ... r-32).................................................................. 48
6.4 Status displays........................................................................................ 48
6.5 Unit status codes .................................................................................... 49
6.6 SEW-Electronics service......................................................................... 49
7 Technical Data................................................................................................. 50
7.1 CE marking, UL approval and C-Tick ..................................................... 50
7.2 General technical data ............................................................................ 51
7.3 Technical data of MOVITRAC 07 ......................................................... 52
8 Change Index................................................................................................... 82
9 Index................................................................................................................. 83
1 Important Notes
Betriebsanleitung
Safety and Always follow the safety and warning notes in this publication!
warning notes
Electrical hazard
Possible consequences: Severe or fatal injuries.
Hazard
Possible consequences: Severe or fatal injuries.
Hazardous situation
Possible consequences: Slight or minor injuries.
Harmful situation
Possible consequences: Damage to the unit and the environment.
Designated use MOVITRAC 07 frequency inverters operate AC asynchronous motors. These motors
must be suitable for operation with frequency inverters. Do not connect any other loads
to the frequency inverters.
Operational The following applications are forbidden unless measures are expressly taken to make
environment them possible:
Use in explosion-proof areas
Use in environments with harmful substances:
Oils
Acids
Gases
Vapors
Dust
Radiation
Other harmful environments
Use subject to mechanical vibration and shock loads in excess of the requirements
in EN 50178
If the inverter performs safety functions which have to guarantee the protection of
machinery and people
Waste disposal Please follow the latest instructions: Dispose of the following materials in accordance
with the regulations in force:
Electronics scrap (circuit boards)
Plastic (housing)
Sheet metal
Copper
2 Safety Notes
Installation and Never install damaged products or take them into operation. Please submit a
startup complaint to the transport company immediately in the event of damage.
Installation, startup and service work on the unit only by trained personnel. The
personnel must be trained in the relevant aspects of accident prevention and must
comply with the regulations in force (e.g. EN 60204, VBG 4, DIN-VDE
0100/0113/0160).
Follow the specific instructions during installation and startup of the motor and
the brake!
Make sure that preventive measures and protection devices correspond to the
applicable regulations (e.g. EN 60204 or EN 50178).
Grounding the unit is a necessary protective measure.
Overcurrent protection devices are a necessary protective measure.
The unit meets all requirements for reliable isolation of power and electronics
connections in accordance with EN 50178. All connected circuits must also satisfy
the requirements for reliable isolation so as to guarantee reliable isolation.
Take suitable measures to ensure that the connected motor does not start up au-
tomatically when the inverter is switched on. To do this, you can connect binary
inputs DI01 through DI03 to GND.
Connection to the frequency inverter output is only permitted in size 0S, 0M and 0L
when the output stage is inhibited.
Operation and Dangerous voltages are present at the output terminals and the cables and
servicing motor terminals connected to them when the unit is switched on. Dangerous
voltages may also be present when the unit is inhibited and the motor at a standstill.
The unit is not necessarily deenergized when the LEDs and the 7-segment
display are off.
Safety functions inside the unit or a mechanical blockage may cause the motor
to stop. The removal of the source of the malfunction or a reset can result in an
automatic restart of the drive. If, for safety reasons, this is not permissible for the
driven machine, disconnect the unit from the supply system before correcting the
fault.
3 Unit Design
3.1 Unit design
Sizes 0S, 0M, 0L
7
3 8
9
4
5 10
6
02978BXX
Figure 1: MOVITRAC 07 unit design, sizes 0S, 0M, 0L
Sizes 1, 2S, 2
05132AXX
Figure 2: MOVITRAC 07 unit design, sizes 1, 2S, 2
Size 3
05295AXX
Figure 3: MOVITRAC 07 unit design, size 3
1. PE connections
2. X1: Mains connection 3-phase: L1 (1) / L2 (2) / L3 (3)
3. X4: DC link circuit connection (not used)
4. PE connections (not visible)
5. X2: Motor connection U (4) / V (5) / W (6)
6. X3: Braking resistor connection R+ (8) / R (9)
7. Operating panel
8. DIP switch S11 changeover U-signal / I-signal
9. X11: RS-485 connection (only for service purposes)
10. DIP switch S12 for system bus terminating resistor
11. X10: Electronics terminal strip
12. Electronics shield clamp
Size 4
05296AXX
Figure 4: MOVITRAC 07 unit design, size 4
1. X2: PE connection
2. X1: Mains connection 3-phase: L1 (1) / L2 (2) / L3 (3)
3. X4: DC link circuit connection (not used)
4. X2: PE connection
5. X2: Motor connection U (4) / V (5) / W (6)
6. X3: Braking resistor connection R+ (8) / R (9) and PE connection
7. Operating panel
8. DIP switch S11 changeover U-signal / I-signal
9. X11: RS-485 connection (only for service purposes)
10. DIP switch S12 for system bus terminating resistor
11. X10: Electronics terminal strip
12. Electronics shield clamp
Type MC
Version A
Recommended motor
022 = 2.2 kW
power
00 = Standard
Type
10 = LOGODrive
MC 07 A 004- 2 B 1- 4- 00
Sample nameplate
02940FXX
Figure 5: Sample nameplate
5 6
3 1
4
2
03000AXX
Figure 6: Scope of delivery of loose items for size 0
4 Installation
Tightening Only use genuine connection elements. Note the permitted tightening torques
torques of MOVITRAC 07 power terminals.
Size 0S/M/L 0.5 Nm (4.4 lb.in)
Size 1 0.6 Nm (5.3 lb.in)
Size 2S/2 1.5 Nm (13.3 lb.in)
Size 3 3.5 Nm (31 lb.in)
Size 4 14 Nm (124 lb.in)
Nm (lb.in)!
02475AXX
Figure 7: Observe the tightening torques
Recommended Use a screwdriver with a 2.5 mm wide blade for connecting the electronics terminal
tools strip X10.
Minimum clear- Leave 100 mm (4 in) clearance at the top and bottom for optimum cooling. No
ance and mount- lateral clearance required; the units can be lined up side-by-side. Make sure that the
ing position circulation of air is not disrupted by cables or other installation materials. Prevent the
heated exhaust air from other units from blowing onto this unit. With sizes 4 and 5,
do not install any components which are sensitive to high temperatures within
300 mm (11.81 in) of the top of the unit. Only install the units vertically. You must
not install them horizontally, tilted or upside down.
Line choke When more than four 3-phase units or more than one 1-phase unit are
connected to an input contactor designed for the total current, insert a line choke
in the circuit to limit the inrush current.
Separate cable Route power cables and electronics cables in separate cable ducts.
ducts
Input fuses and Install input fuses at the start of the supply system lead after the supply bus
earth leakage junction. Use type D, DO, NH fuses or power circuit breakers.
circuit breakers Using an earth-leakage circuit breaker as the sole protection device is not
permitted. Earth-leakage currents > 3.5 mA can arise during normal operation of
the inverter.
PE input Connect the PE conductor according to the regulations of the country in question.
connection Connect the protective earth connector of the motor to the PE terminal of the
corresponding inverter.
Use grounding cables with a large cross section to ground all units to a common
earth connection point or grounding bar by the shortest possible route.
Make sure the connection between inverter and earthed metallic installation platform
is conductive (wide area metal-on-metal contact between the heat sink and ground,
e.g. unpainted control cabinet mounting panel). Use high-frequency compatible
earthing strips.
Establish an equipotential bonding between system / control cabinet and drive /
motor (e.g. through one-piece cable rack).
Earth-leakage currents > 3.5 mA can arise during normal operation of the inverter.
Shielding and Shield the control cables.
earthing Connect the shield by the shortest possible route and make sure it is earthed over a
wide area.
You can ground one end of the shield via a suppression capacitor (220 nF / 50 V) to
avoid ground loops.
If using double-shielded cables, ground the outer shield on the inverter end and the
inner shield on the other end.
Provide high frequency compatible earthing for MOVITRAC 07 and all additional
units (wide area metal-on-metal contact between the heat sink and ground, e.g.
unpainted control cabinet mounting panel).
00755BXX
Figure 8: Correct shield connection using metal clamp (shield clamp) or metal cable gland
If possible, control cables and supply cables should intersect at right angles.
You can also use earthed sheet-metal ducts or metal pipes to shield the cables.
IT systems SEW recommends using earth-leakage monitors with a pulse code measuring
process in voltage supply systems with a non-earthed star point (IT systems).
This avoids mis-tripping of the earth-leakage monitor due to the earth capacitance of
the inverter.
Contactor Only use contactors in utilization category AC-3 (IEC 158-1).
Cross sections Supply system lead: Cross section according to nominal input current Isystem at
rated load
Motor cable: Cross section according to rated output current IN
Electronics cables: Maximum 1.5 mm2 (AWG16) without conductor end sleeves
Maximum 1.0 mm2 (AWG17) with conductor end sleeves
Line lengths for The line lengths for size 0 are independent of the PWM frequency. The motor leads for
single drives sizes 1 through 4 depend on the frequency. The permitted motor cable lengths are listed
in Sec. "Project Planning" of the MOVITRAC 07 system manual.
Unit output Only connect an ohmic/inductive load (motor); do not connect a capacitive load!
ConnectionBrak- Shorten the cables to the required length.
ing resistor
Binary inputs / Binary outputs are short-circuit proof and interference-voltage-proof up to
binary outputs 35 V. They can suffer irreparable damage from higher external voltages!
Interference Use shielded motor cables or HD output chokes for EMC-compliant installation.
emission
Switched Use suppressors to suppress interference on contactors, relays, solenoid valves,
inductances etc.
The minimum distance to the inverter should be 150 mm.
Line filter MOVITRAC 07 frequency inverters have an integrated input filter as standard. They
comply with the following limit value class to EN 55011 on the line side without further
measures:
B: 1-phase connection
A: 3-phase connection
230 V: up to 7.5 kW
400/500 V: up to 11 kW
No EMC limits are specified for interference emission in voltage supply systems without
an earthed star point (IT systems). The effectiveness of input filters is severely limited.
Flat-type braking Insert the braking resistor into the back of the heat sink. Install the braking resistor in the
resistor BW for heat sink with the four screws provided.
size 0
03164AXX
Figure 9: Installing the braking resistor BW
HD output choke Install the output choke close to MOVITRAC 07 beyond the minimum clearance.
Always route all three phases (not the PE!) together through the output choke.
If the cable is shielded, the shield is not allowed to be routed through the output
choke.
02979BXX
Figure 10: Connecting HD output chokes
With the HD output choke, the cable must be wrapped around the choke 5 times.
Less than five loops are possible if the cable has a large diameter. To make up for this,
two or three output chokes should be connected in series. Two output chokes should be
connected in series if there are four loops, and three output chokes in series if there are
three loops.
400/500 V units
MOVITRAC 07 Max. supply Max. supply voltage Fuses
current
005/008/011 AC 5000 A AC 500 V 15 A / 600 V
015/022/030 AC 5000 A AC 500 V 35 A / 600 V
040 AC 5000 A AC 500 V 45 A / 600 V
055/075 AC 5000 A AC 500 V 60 A / 600 V
110 AC 5000 A AC 500 V 110 A / 600 V
150/220 AC 5000 A AC 500 V 175 A / 600 V
300 AC 5000 A AC 500 V 225 A / 600 V
370/450 AC 10 000 A AC 500 V 350 A / 600 V
1
2
02012BXX
Figure 11: Power shield clamp for MOVITRAC 07 size 1
1. Shield clamp
2. PE connection ()
Size 2S / 2 SEW-EURODRIVE supplies a power shield clamp with two retaining screws as
standard with MOVITRAC 07 size 2S / 2. Install this power shield clamp together with
the two retaining screws on X6.
01469BXX
Figure 12: Power shield clamp for MOVITRAC 07 size 2S / 2
1. Shield clamp
2. PE connection ()
Power shield clamps provide you with a very convenient way of installing the shield for
the motor and brake cables. Install the shield and PE conductor as shown in the figures.
IP10
X4
-UZ +UZ PE
IP20
X4
-UZ +UZ PE
IP10
X3
8/+R 9/-R PE
IP20
X3
8/+R 9/-R PE
54447AXX
Figure 13: Touch guard for MOVITRAC 07 size 2S
Size 4 SEW-EURODRIVE supplies two touch guards with eight retaining screws as standard
with MOVITRAC 07 size 4. Install the touch guard on both covers of the power section
terminals.
01470BXX
Figure 14: Touch guard for MOVITRAC 07 size 4
When the touch guard is installed, MOVITRAC 07 size 4 has enclosure IP10. The units
have IP00 without touch guard.
4.5 Wiring diagram 230 V 0.37 ... 2.2 kW / 400 V 0.55 ... 4.0 kW
L1 L1
3 x 230 VAC / PE L2
L3 N 1 x 230 VAC / N / PE
3 x 400/500 VAC / PE
PE PE
F11/F12/F13 F11
K11 K11
(AC-3) (AC-3)
3-phase X1 L1 L2 L3 PE 1-phase X1 L N PE
AI11
AI12
DO2 Brake*
DI04 n11/n21*
DI05 n12/n22*
DI01 CW/Stop
DI03 Enable*
VOTF
VO24
SC11
SC12
SC21
SC22
Fault*
GND
GND
GND
GND
- +
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 X10
VAC
F14/F15
K11
on K12
0...+10V
(AC-3)
System bus Low
System bus Low
V
1
0(4)...20mA
2
3 DO2 Control
4 GND
BMK
RD
13 I
14 WH
15 BU
DC and AC
disconnect
X2 U V W PE PE +R -R X3
VAC VAC
F14/F15 F14/F15 = Shield clamp
DO2 DO2
* = Factory setting
K12 K12
(AC-3) (AC-3) F16
GND GND
Affects
1 WH 1
WH K11 BW...
BG 2 RD BG 2 RD M
3 3
BGE 4 BGE 4 3-phase
BU BU
5 5 P820
DC and AC AC = ON!
disconnection disconnection
02943LEN
Figure 15: Wiring diagram for size 0
3-phase X1 L1 L2 L3 PE
V* ON System bus
Toggle switch
RS-485 terminating
I signal V signal*
mA X11 OFF* resistor
S 11 S 12
DO1-NO
DO1-NC
DO1-C
DI02 CCW/Stop*
AI11
AI12
DO2 Brake*
DI01 CW/Stop
DI04 n11/n21*
DI05 n12/n22*
DI03 Enable*
Strung*
VOTF
VO24
SC11
SC12
SC21
SC22
GND
GND
GND
GND
- +
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 X10
VAC
F14/F15
K11
on K12
0...+10V
System bus High
V
1
0(4)...20mA
2
3 DO2 Control
4 GND
BMK
RD
13 I
14 WH
15 BU
AC and DC
disconnection
X2 U V W PE +R -R PE X3
VAC VAC
F14/F15 F14/F15 = Shield clamp
DO2 DO2
* = Factory setting
K12 K12
(AC-3) (AC-3) F16
GND GND
Affects
WH WH K11
1 1 BW...
BG 2 RD BG 2 RD M
3 3
BGE 4 BGE 4 3-phase
BU BU
5 5 P820
DC and AC AC = ON!
disconnection disconnection
05134CXX
Figure 16: Wiring diagram for sizes 1 ... 4
A separate supply system lead is required for connecting the brake rectifier;
supply from the motor voltage is not permitted!
Only use contactors in utilization category AC-3 (IEC 158-1) for K11 and K12.
Always switch off the brake on the DC and AC sides under the following conditions:
All hoist applications
Drives which require a rapid brake reaction time.
If the brake rectifier is installed in the control cabinet, route the connecting leads
between the brake rectifier and the brake separately from other power cables. Routing
together with other cables is only permitted if the other cables are shielded.
Note the corresponding connection regulations for brakes without BG/BGE or BME.
Please refer to the publication "Drive Engineering - Practical Implementation, Vol. 4" for
detailed information about SEW brakes.
05817AXX
Figure 17: MOVITRAC 07 system bus connection
GND = System bus reference
SC22 = System bus low
SC21 = System bus high
SC12 = System bus low
SC11 = System bus high
S12 = System bus terminating resistor
5 Startup
Using the IN/OUT key : Press the key once to go further down into the menu struc-
ture (to select functions). To change to higher levels in the menu structure, press the key
twice or make a long keypress.
Prerequisite Correct project planning of the drive is the prerequisite for successful startup.
MOVITRAC 07 frequency inverters are factory set to be taken into operation with the SEW
motor which is adapted to the correct power level (4-pole, 50 Hz).
You can connect the motor and start the drive immediately.
The startup functions described in this section are used to set the inverter so it is opti-
mally adapted to the connected motor and to the given boundary conditions.
The inverter automatically changes parameter values once you perform a startup.
Functions of the The UP, DOWN and IN/OUT keys are used for navigating through the menu. The RUN
operating panel and STOP/RESET keys are used for controlling the drive. The setpoint potentiometer is
used for selecting setpoints.
STOP
"STOP/RESET" to reset faults and stop the drive.
RESET
Stopping the drive with the STOP/RESET key is not a safety function. Switching the
power off unlocks the inverter again and you can enable the inverter.
[rpm] [rpm]
2x
[A] 1x
[s/rpm]
02968DXX
Figure 18: Principles of operation using the integrated operating panel (2x = press twice)
Available sym- You can select the following symbols using the keys and :
bols
Symbol Function
rpm Displays the inverter status or (in "drive enabled" status) the calculated actual speed
in [rpm]
Menu system The LED integrated in the symbol lights up when you select a symbol. If a symbol only
represents display values, the current display value appears immediately on the 7-seg-
ment display.
Editing parameters After selecting the symbol Par (display: P---), you can select the required parameter
by pressing and den gewnschten Parameter anwhlen.
Pressing the key once displays the number of the required parameter. To edit the
parameter value, press the key again. You can alter the value when the LED in the
corresponding symbol flashes. The value takes effect when you exit edit mode by press-
ing the key twice, or about 1 s after your last keypress.
Display For the terminal assignment parameters (601 ... 604, 620, 621) you can select from pre-
set combinations using parameters 60- and 62-. If you set a different combination with
MOVITOOLS, the display shows ----.
Status displays To display the status, select the rpm symbol. If the status is "Drive enabled", the calcu-
lated actual speed will be displayed.
Drive "Controller inhibit": dIS (disable)
Drive "No enable": StoP (Stop)
Drive "Enabled": 8888 (actual speed)
Factory settings being reactivated: SEt (Set)
Current at standstill: dc
Fault indication If a fault occurs, the display changes to the rpm symbol and shows the flashing fault
code, e. g. F-11 (list of faults, see Sec. Operation and servicing).
Warnings Some parameters are not allowed to be altered in all operating states. If you try to do so,
the following display appears:r-19 ... r-32. The display shows a code depending on
the action, e.g.r-28 (controller inhibit necessary). See Sec. Operation and servicing for
a list of warnings.
5.5 Manual Manual speed control module and external setpoint selection
Manual speed control module of the operating panel (local manual operation): LED
flashes
External setpoint selection
Control via:
Terminals
Serial interface
Setpoint potentiometer on AI11/AI12
03158BXX
Figure 19: Manual setpoint adjustment (2x = press twice)
The only relevant parameters in "manual speed control module" operating mode are
P122 local potentiometer mode
"RUN" and "STOP/RESET" keys
Setpoint potentiometer
An activated manual speed control module is indicated by flashing LEDs rpm and .
You can limit the speed by setting the parameters P301 Minimum speed and P302 Max-
imum speed.
After a fault, you can perform a reset via terminal or interface by pressing the "STOP/RE-
SET" key. After a reset, the "Manual speed control module" operating mode is active
again. The drive remains stopped.
The Stop display flashes to indicate that you have to re-enable the drive by pressing
the "RUN" key.
The P760 Locking RUN/STOP keys parameter does not have any effect in "manual
speed control module" operating mode.
External setpoint To enable the inverter, press the "RUN" key. To stop the inverter, press the "STOP/RE-
selection SET" key. You can switch off the function of both keys using P760 Locking RUN/STOP
keys.
Direction of rota- You can specify the direction of rotation setpoint:
tion setpoint "CW/STOP" and "CCW/STOP" in P101 Control signal source = TERMINALS or
P101 Control signal source = 3 WIRE-CONTROL
The polarity of the setpoint in the process data word in P101 Control signal source =
RS485 or SBus and P100 Setpoint source = RS485 or SBus
Setpoint speed You can assign the setpoint speed:
The setpoint potentiometer (if P121 Addition Setpoint Potentiom. is set to ON)
P100 Setpoint source
Fixed setpoints
Fixed setpoints with analog input
Process data word from SBus or RS-485 (RS-485 only for service purposes)
Motor potentiometer
Enable direction of The direction of rotation is determined by the setpoint if you set P101 Control signal
rotation with RS- source and P100 Setpoint source to RS485 or SBus (RS4-85 only for service purposes).
485 or SBus You must enable the setpoint via SBus or RS-485 using the "CW/STOP" or
"CCW/STOP" terminal. SEW-EURODRIVE recommends to enable the setpoint us-
ing the "CW/STOP" terminal, which has a fixed program setting, rather than with the
programmable "CCW/STOP" terminal.
"CW/STOP" "CCW/STOP" Direction of rotation enable
terminal terminal
0 0 Drive inhibited
1 0 CCW and CW (direction of rotation depends on the set-
point)
0 1 CCW and CW (direction of rotation depends on the set-
point)
1 1 Drive inhibited
STOP/RESET The STOP/RESET key has priority over enable via terminal or interface. If you stop a
drive using the STOP/RESET key, you have to enable it again using the RUN key.
STOP
RESET
Switching the power supply system off and on re-enables the inverter!
You can perform a reset after a fault has occurred with a programmed fault response by
pressing the STOP/RESET key. The drive is then inhibited and must be enabled using
the RUN key.
RUN If you stop the drive with the STOP/RESET key, the Stop display flashes. This
indicates you have to enable the drive using the "RUN" key.
RUN
02975GXX
Figure 20: Startup using the integrated operating panel (2x = press twice / * = factory setting)
P-01 = Operating mode P-03 = Rated motor speed P-05 = Rated motor voltage
P-02 = Rated motor power P-04 = Rated motor frequency
General If you do not connect the motor indicated in the motor selection table: Enter parameters
information P-01 through P-05 correctly according to the nameplate (access via ):
No. Name Range / factory setting
P-01 Operating mode 0 VFC or VFC & HOIST (can only be set in MOVI-
TOOLS)
3 VFC & DC BRAKE
4 VFC & FLYING START
21 V/f CHARACTER.
22 V/f CHARACTER.& DC BRAKING
P-02 Rated motor power 0.25 [kW]
0.37 Factory setting: Rated motor power in kW corre-
0.55 sponding to the rated inverter power
...
If a smaller or a larger motor is connected (maximum
difference one frame size), then a value must be
selected which is as close as possible to the rated
motor power.
P-03 Rated motor speed 10 ... Rated motor speed ... 5500 [rpm]
P-04 Rated motor frequency 50 [Hz]
60
P-05 Rated motor voltage 50 ... 700 [V]
Startup automatically sets the maximum speed P302 to the transition speed.
VFC The default operating mode setting is V/f. You must start up the inverter in VFC or VFC
+ DC BRAK. operating mode for:
High torque
Continuous duty at low frequencies
Accurate slip compensation
More dynamic properties
To choose VFC or VFC + DC BRAK. operating mode, select the symbol in item P-
01 to choose VFC or VFC & DC BRAK. operating mode.
Startup of group V/f CHARACTER. operating mode allows for operating a group of asynchronous motors
drives on one inverter. Please note:
Select V/f operating mode
Set the power of the largest motor
Disable automatic adjustment P320
Set IxR compensation P322 to zero
Set slip compensation P324 to zero
Set the current limitation to 1.5 times the total current of the motors
In this operating mode, the inverter operates without slip compensation and with a con-
stant V/f ratio.
The following travel cycle shows by way of example how you start the drive with the wir-
ing of terminals X10:2 ... X10:6 and the internal fixed setpoints.
02981ADE
Figure 21: Travel cycle with internal fixed setpoints
131 8808 Ramp t11 down 0.1 ... 2 ... 2000 [s]
Send in for repair Please contact the SEW electronics service if a fault cannot be rectified (
"Customer and spare parts service").
When contacting the SEW electronics service, always quote the digits of the service
code so that our service personnel can assist you more effectively.
Please provide the following information when sending the unit in for repair:
Serial number ( nameplate)
Unit designation
Brief description of the application (application, control via terminals or serial)
Connected motor (motor voltage, star or delta connection)
Nature of the fault
Accompanying circumstances
Your own presumption of what has happened
Unusual events which preceded the fault
7 Technical Data
7.1 CE marking, UL approval and C-Tick
CE marking
Low Voltage MOVITRAC 07 frequency inverters comply with the regulations of the Low Voltage
Directive Directive 73/23/EEC.
Electromagnetic MOVITRAC 07 frequency inverters are components of machines and systems. They
compatibility EMC comply with the EMC product standard EN 61800-3 Variable-speed electrical drives. If
you want to apply the CE mark to the machine/system equipped with frequency inverters
in accordance with the EMC Directive 89/336/EEC, observe the instructions regarding
EMC compliant installation.
MOVITRAC 07 frequency inverters have an integrated line filter as standard. They
comply with the following limit value class to EN 55011 on the line side without further
measures:
B: 1-phase connection
A: 3-phase connection
230 V: 0,37 ... 7.5 kW
400/500 V: 0,55 ... 11 kW
The CE mark on the nameplate shows that the product meets the requirements of the
following directives:
Low Voltage Directive 73/23/EEC
EMC Directive 89/336/EEC
SEW-EURODRIVE provides a declaration of conformity if requested.
UL approval UL and cUL approval has been granted for the entire MOVITRAC 07 series. cUL is
equivalent to CSA approval.
C-Tick C-Tick approval has been granted for the entire MOVITRAC 07 series. C-Tick certifies
conformity with the requirements of the ACA (Australian Communications Authority).
The inverter must at least comply with class A limit to obtain approval to use the C-Tick
mark. See Sec. [Installation] / [Installation notes.]
51115AXX
Figure 22: MOVITRAC 07 230 V units
Size 0S 0L 1 2 3 4
Power [kW / HP] 0.37 / 0.5 1.1 / 1.5
5.5 / 7.5 11 / 15 22 / 30
0.55 / 0.75 1.5 / 2.0 3.7 / 5
7.5 / 10 15 / 20 30 / 40
0.75 / 1.0 2.2 / 3.0
Mains connection 230 V / 1-phase
230 V / 3-phase
230 V / 3-phase
400/500 V
51116AXX
Figure 23: MOVITRAC 07 400/500-V units
Size 0M 0L 2S 2 3 4
Power [kW / HP] 1.5 / 1.0
0.55 / 0.75 15 / 20
2.2 / 3.0 5.5 / 7.5 37 / 50
0.75 / 1.0 11 / 15 22 / 30
3.0 / 4.0 7.5 / 10 45 / 60
1.1 / 1.5 30 / 40
4.0 / 5.0
Mains connection 400/500 V / 3-phase
51105AXX
Figure 24: MOVITRAC 07 / size 0S / 1-phase AC 230 V
05804AXX
Figure 25: Dimensions, MOVITRAC 07 size 0S
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
150 (5.9)
295 (11.6)
306 (12.1) / M5
330 (13.0)
90 (3.5)
54559AXX
Figure 27: Dimensions, MOVITRAC 07 size 0L
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
51105AXX
Figure 28: MOVITRAC 07 / size 0S / 3-phase AC 230 V
05804AXX
Figure 29: Dimensions, MOVITRAC 07 size 0S
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
150 (5.9)
295 (11.6)
306 (12.1) / M5
330 (13.0)
90 (3.5)
54559AXX
Figure 31: Dimensions, MOVITRAC 07 size 0L
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05806AXX
Figure 33: Dimensions, MOVITRAC 07 size 1
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05807AXX
Figure 35: Dimensions, MOVITRAC 07 size 2
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05808AXX
Figure 37: Dimensions, MOVITRAC 07 size 3
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05809AXX
Figure 39: Dimensions, MOVITRAC 07 size 4
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
150 (5.9)
245 (9.6)
256 (10.1) / M5
280 (11.0)
90 (3.5)
54560AXX
Figure 41: Dimensions, MOVITRAC 07 size 0M
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
150 (5.9)
295 (11.6)
306 (12.1) / M5
330 (13.0)
90 (3.5)
54559AXX
Figure 43: Dimensions, MOVITRAC 07 size 0L
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05811AXX
Figure 45: Dimensions, MOVITRAC 07 size 2S
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05807AXX
Figure 47: Dimensions, MOVITRAC 07 size 2
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05808AXX
Figure 49: Dimensions, MOVITRAC 07 size 3
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
05809AXX
Figure 51: Dimensions, MOVITRAC 07 size 4
Provide 100 mm (4 in) clearance above and below the unit to ensure adequate cooling!
There is no need for clearance at the sides. You can line up the units directly next to one
another. Make sure that the circulation of air is not disrupted by cables or other installa-
tion materials. Prevent the heated exhaust air from other units from blowing onto this
unit.
MOVITRAC 07 size 0S, 0M, 0L for support rail mounting (optional accessory)
04329AXX
Figure 52: MOVITRAC 07 dimensions for DIN rail mounting (optional accessory)
MOVITRAC 07 400/500 VAC 005 008 011 015 022 030 040
Dimensions AxBxC 90 x 245 x 150 mm 90 x 295 x 150 mm
3.5 x 9.7 x 5.9 in 3.5 x 9.5 x 5.9 in
Mounting b/c/ 200 mm / 162 mm / 250 mm / 162 mm /
d/e 211 mm (M4) / 14.75 mm 261 mm (M4) / 14.75 mm
7.9 in / 8.7 in / 9.8 in / 6.4 in /
8.3 in (M4) / 0.6 in 10.3 in (M4) / 0.6 in
Size 0M 0L
8 Change Index
9 Index
Input fuses .......................................................... 14
Installation .......................................................... 13
A
Installation notes ................................................ 13
Acceleration ramp ...............................................28 Integrated operating panel ................................. 26
Activating startup ................................................33 Interference emission ......................................... 51
Actual speed .......................................................28 Inverter parameters ............................................ 28
Ambient temperature ..........................................51 Inverter status .................................................... 28
Analog setpoints .................................................34 IT system ............................................................ 15
Apparent output current ......................................28
L
B
Line choke .......................................................... 14
Brake rectifier ......................................................23 Line filter ............................................................. 15
Braking resistor ...................................................16 Line length .......................................................... 15
Braking resistors, connection ..............................15 List of faults ........................................................ 46
C List of warnings .................................................. 48
C-Tick ..................................................................50 Load ................................................................... 35
CE marking .........................................................50 LOGODrive ........................................................ 35
Class B limit ................................................. 15, 50 Loose items ........................................................ 12
CSA .....................................................................50 Low Voltage Directive ........................................ 50
cUL ......................................................................50 M
D Manual operation ............................................... 28
Deceleration ramp ...............................................28 Manual speed control menu ............................... 28
Designated use .....................................................4 Manual speed control module ............................ 29
Digital control ......................................................34 Maximum speed ................................................. 28
DIN rail mounting ................................................81 Menu system ...................................................... 28
Direction of rotation .............................................30 Motor lead .......................................................... 15
Direction of rotation setpoint ...............................30 O
E Operating mode ........................................... 32, 33
Earth leakage circuit-breaker ..............................14 Operating panel .................................................. 26
Earth-leakage monitors .......................................15 Operational environment ...................................... 5
Earthing ...............................................................14 Output choke ...................................................... 17
Editing parameters ..............................................28 P
Electromagnetic compatibility .............................50 Parameter list ..................................................... 36
Electronics service ..............................................49 PE input connection ........................................... 14
EMC ....................................................................50 Power reduction ................................................. 51
EMC limits ...........................................................15 Programming interface ....................................... 35
Enable direction of rotation .................................31
Enclosure ............................................................51 R
Explosion-proof areas ...........................................5 r-19 ... r-32 ......................................................... 48
External setpoint selection ........................... 29, 30 Rapid stop .......................................................... 44
Reset .................................................................. 45
F
RS-485 ............................................................... 31
F-00 ... F-97 ........................................................46 RUN key ............................................................. 31
Fault indication ....................................................29
Fault information .................................................44 S
Fault memory ......................................................44 Safety Notes ......................................................... 6
Fixed setpoint n11 ...............................................28 Safety notes ......................................................... 4
Fixed setpoint n12 ...............................................28 SBus ................................................................... 31
Functional description of the terminals ...............23 Scope of delivery ................................................ 12
Fuses, UL compliant installation .........................18 Setpoint selection, external .......................... 29, 30
Setpoint speed ................................................... 30
I
Shielding ............................................................ 14
Immediate switch-off ...........................................44 Speed ................................................................. 30
Input contactor ....................................................14 Speed control module, manual .......................... 29