KL08RF
Installation and Wiring Guide
GROUP 1 GROUP 2
BATTERY POWERED GROUP CONTROL GROUP 1 GROUP 1 GROUP 1 GROUP 2 GROUP 2 CONTROL STANDALONE
PROGRAMMABLE THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT PROGRAMMABLE
ROOM THERMOSTAT MAINS POWERED (VS20WRF) (VS10WRF) (VS20WRF) (VS10WRF) (VS20WRF) ROOM THERMOSTAT
(MODEL VS20WRF) (MODEL VS10WRF)
VS10W
WRF)
L N
Warning
This product must be fitted by a competent person, and
installation must comply with the guidance, standards and
regulations applicable to the country or state where the
product is installed. Failure to comply with the requirements
of the relevant guidance, standards and regulations could lead
to injury, death or prosecution.
SUPPLIED CABLES
Warning
Always isolate the AC mains supply before installing or working
N L on any components that require 230 V AC 50Hz supply.
External power supply
Warning
The earth terminals on the KL08RF are for earth parking only.
These terminals provide no earth protection.
1 Remove the plastic 4 Cut the power and 8 Push the thermal actuator wires into the 13 Attach the red strain-relieving strip 16 Plug in the CO10RF coordinator.
Zone 4 actuators
Zone 5 actuators
Demand from group 1, zone 4 thermostat: actuator open
Demand from group 2, zone 1 thermostat: actuator open
cover. Open (and
close) the four white
device cable to
length.
round holes at the bottom of the
KL08RF. You can connect up to three
using the three screws to secure the
pump, boiler, CO, and dew point wires Zone 6 actuators
Demand from group 2, zone 2 thermostat: actuator open
10mm
screws with a quarter actuators in each zone. to the bottom side of the KL08RF. Zone 7 actuators Demand from group 2, zone 3 thermostat: actuator open
turn only. Note that
screws on opposite sides Zone 8 actuators
Demand from group 2, zone 4 thermostat: actuator open
10mm
Pump Pump on
50mm
Power/Thermostat
direction.
Boiler
Boiler on
Device
CO Heating mode
Cooling mode
5 Replace the 9 Push in the Pump wires at the bottom 14 Set the boiler delay, wireless, and thermal 17 Replace the Connecting the KL08RF(s) to the ZigBee
Wireless Network
white terminal right of the KL08RF for volt-free pump actuator jumpers at the top right of the plastic cover.
connection board switching. 1. On powering up the KL08RF, all actuator
KL08RF.
LEDs light up green then go off, then the
Jumper Settings/Positions for Pump/Boiler On/Off Delay Network Status LED flashes green.
2. Press and hold the button on the
The pump/boiler on delay and the pump off
coordinator for five seconds. The button
delay are fixed at three minutes. The default
flashes red to indicate the coordinator is
setting for the boiler off delay is also three
ready to pair.
2 Remove the minutes, but can be changed to 15 minutes.
To do this, carefully remove the jumper and The Network Status LED on the KL08RF goes steady green when
white terminal
Switch on mains connected.
connection board re-insert it in the other position as shown below: 18 power supply to 3. Repeat the process for every KL08RF in the system. Note that one
the unit. The red coordinator can support up to nine KL08RFs.
LED comes on. 4. To identify your KL08RF (WC) number press Pair for one second. The
LED on the zone number lights green: Zone 1 = WC -1, Zone 2 = WC -
6 Push the power 10 Push in the Boiler wires at the bottom
2, and so on. The Network Status LED is used to identify WC-9.
wires into the round right of the KL08RF for volt-free boiler
power holes. switching. When a zone calls for heat, Wireless 5. To pair your VS10RF or VS20RF thermostats, see your thermostat
the boiler switch closes causing the manual.
The default setting for the wireless connection 6. Press the coordinator button for five seconds until the LED shines
boiler to run. is internal (INT). To change this setting to steady red.
external (EXT), carefully remove the jumper and
re-insert it in the other position as shown below:
19 If you need to install the optional Note: To restore the KL08RF back to factory default settings at any time,
external antenna and have set the using a suitable tool, press the Reset button to the right of the Pair
Wireless jumpers to EXT: button.
a. Disconnect power. Checking the System Configuration and Communication
Press and hold the coordinator button for one second. All devices
b. Remove the protective connected to the system flash. To stop checking, press and hold the
cap from the antenna coordinator button again for one second.
Type of Actuator connection on the Press and hold the Pair button on the WC for five seconds. All devices
The default setting for the type of actuator is underside of the connected to the KL08RF flash. To stop checking, press and hold the
3 Attach the back of 7 Attach the white 11 Push in the CO wires at the bottom normally closed (NC). To change this setting to KL08RF. Pair button again for five seconds.
the KL08RF to the strain-relief using right of the KL08RF for volt-free normally open (NO), carefully remove the
DIN rail or wall. the two screws to secure heating/cooling changeover switching. Deleting all Devices from the Wireless Network
jumper and re-insert it in the other position as c. Screw the antenna into
the power wires. An open switch is for heating (red LED). To delete all devices connected to the network, press and hold the
shown below. Note that the actuator setting and the KL08RF.
A closed switch is for cooling (blue LED). coordinator button for 15 seconds. The colour of the button changes
thermostat setting must be the same.
from red to amber.
d. Reconnect power. The
To delete all devices connected to the KL08RF, press and hold the
KL08RF will now use Network Status button on the KL08RF for 15 seconds. The G1 and G2
Heating mode the external antenna LEDs turn from flashing red to solid red then go off.
and not the internal
Cooling mode Note: After all devices have been deleted from the wireless network, they
antenna.
will need to be reinstalled. Refer to the instruction manuals.