HMI and PLC Connecting Guide PDF
HMI and PLC Connecting Guide PDF
HMI and PLC Connecting Guide PDF
CONTENTS
MT5000/4000 SERIES HMI AND PLC CONNECTING GUIDE ............................................... 3
1
CORO VISION
2
CORO VISION
3
CORO VISION
HMItek Ltd. will continuously provide drivers for various brands of printers.
Note: The maximum distance of printer cable is 5m.
Pin Designations Pin assignment of 15-pin, D-SUB, female, parallel printer port
Pin# Signal Function Pin# Signal Function
1 GND Signal ground 10 BUSY Input
2 DATA7 Output 11 DATA8 Output
3 DATA4 Output 12 DATA5 Output
PRINTER(15-pin) 4 DATA1 Output 13 DATA2 Output
5 STB Output 14 INIT Output
7 DATA6 Output 15 nERROR Input
8 DATA3 Output
Pin assignment of 25-pin, D-SUB, female, parallel printer port
Pin# Signal Function Pin# Signal Function
1 STB Output 8 DATA7 Output
PRINTER(25-pin) 2 DATA1 Output 9 DATA8 Output
3 DATA2 Output 11 BUSY Input
4 DATA3 Output 15 ERROR Input
5 DATA4 Output 16 INIT Output
6 DATA5 Output 18-25 GND Signal ground
7 DATA6 Output
4
CORO VISION
STB
Printer 26 pin port 1 5 4300 series HMI
Notethe red line is the first pin 15 pin port
DATA1
3 4
DATA2
5 13
ERROR
4 15
7 DATA3 8
DATA4
9 3
DATA5
11 12
DATA6
13 7
DATA7
15 2
DATA8
17 11
BUSY
21 10
10 GND 1
5
CORO VISION
a. WH4008A31-053 Serial port printing mode, pulling up W1 short circuit block by RS232 level.
6
CORO VISION
7
CORO VISION
Printer series 25 pin convert to 15 pin of the MT4300 series touch screen
8
CORO VISION
9
CORO VISION
Download by USB
10
CORO VISION
ABB Corporation
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COMM Type Parameter Cable
ABB AC31 O7KR51-V3.6 RS232 on the CPU unit RS232 Setting Your owner cable
RS485 RS485-2 Setting Your owner cable
PM571
RS232 on the port 1 RS232 Setting Your owner cable
ABB AC500 PM581
PM591 RS232 on the port 2 RS232 Setting Your owner cable
Communication Settings
HMI
ABB AC31 Default communication parameters 9600, 8, none, 1; station No. :1
RS232
11
CORO VISION
RS485
12
CORO VISION
Supported Device
ABB AC31
Device Bit Address Word Address Format
Input bit I00.00-68.15 DD.DD
Output bit O00.00-68.15 DD.DD
Indirect Register
(Double words) KD0.00-7.15 D.DD
ABB AC500
Device Bit Address Word Address Format
PLC Register MB0.08191.7 DDDD.O
Internal Register MW0.01.32767 D.DDDDD
Internal Register (Double words) MD0.01.16383 D.DDDDD
Note
1Select MODBUS mode in the ABB AC500 programming software;
2 If selecting COM1 MODBUS, serial communication setting must be slave in the 15th
Operation mode. Other parameters match the touch-screen.
3Example: MB address: 0.0.1, please input 0.1 in the HMI.
Cable Diagram
ABB AC31 RS232
13
CORO VISION
Allen-Bradley
Serial Communication
Series CPU Link Module Driver
MicroLogix 1500
(1764-LRP) Channel 1 AB DF1
MicroLogix 1000 Channel 0
MicroLogix 1200 AIC+ Advanced Interface
MicroLogix
MicroLogix 1500 Converter
(1764-LSP,1764-LRP) 1761-NET-AIC
MicroLogix 1400 Channel 0
(1766-L32BWAA) Channel 2
SLC500 SLC 5/03 Channel 0
SLC 5/04
SLC 5/05
1770-KF3
2760-RB
1775-KA
14
CORO VISION
5130-RM
1771-KGM
PLC-5/11
PLC-5/20
PLC-5/30
PLC-5 PLC-5/40 Channel 0
PLC-5/40L
PLC-5/60
PLC-5/60L
1769-L20
1769-L30
CompactLogix 1769-L31 Channel 0
AB CompactLogix/ControlLogix
1769-L32E Channel 1
1769-L35E
ControlLogix 1756-L61
CPU Direct AB CompactLogix/ControlLogix
1756-L63
SLC500 SLC5/03
SLC5/04 1761-NET-ENI
SLC5/05
15
CORO VISION
16
CORO VISION
17
CORO VISION
18
CORO VISION
Note: Define the new device in the RSLogix5000 before using the register in the HMI.
(2) Define Tags and Data type: select controller tags right-click>edit tags, set up Tags:
Note: When the Data Type isnt defined data array, only one address is available to use; how to define the Tag
Number, you can refer to the RSLogix5000 manual.
(3) Assign the Tag Name created by RSLogix5000 to the optional File Name: select
logic--->map PLC/SLC messages.Note: the state of program software change to offline
Note: You can not assign different Tag Names to the same File Number.
Network configuration
19
CORO VISION
PLC configuration
Supported Device
MicroLogix 1200
Device Bit Address Word Address Format Notes
Bit data file B100.0-254.15 DDD.DD
Bit data file B30.0-254.15 DDD.DD
20
CORO VISION
Compactlogix L31
Device Bit Address Word Address Format
21
CORO VISION
Cable Diagram
MicroLogix 1200 RS232 cable diagram
1. Cable made by AB Corporation
22
CORO VISION
EtherNet cable
Connecting PC and HMI use cross-ruling; communicating with hub or switch use Cross-over cable or
cross-ruling.
a. cross-ruling cable diagram:
23
CORO VISION
Serial Communication
Series CPU Link Module Driver
SA2103 SB214SA RS232 on the CPU unit ACS-Tech80
System configuration
Series CPU Link Module COM Type Parameter Cable
SA2103 SB214SA RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
RS232 communication
Supported Device
24
CORO VISION
Cable Diagram
RS232 communication cable
HMI terminal
9pin D-SUB female/male
Controller terminal
com0/com1 com2 9 pin D-SUB (male)
2 RX 7 RX 3 TXD
3 TX 8 TX 2 RXD
5 GND 5 GND 5 GND
ADAM
Serial Communication
Series CPU Link Module Driver
ADAM-4017 RS485 on the CPU unit ADAM-4017
ADAM
ADMA-4015 RS485 on the CPU unit ADMA-4015
25
CORO VISION
System configuration
Series CPU Link Module COMM Type Parameter Cable
ADAM-4017 RS485on the CPU unit RS485 Setting Your owner cable
ADAM
ADMA-4015 RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
HMI
ADAM-4017 default communication: 9600, 8, none, 1; station: 255
26
CORO VISION
Supported Device
ADAM-4017
Device Bit Address Word Address Format
27
CORO VISION
ADAM-4015
Device Bit Address Word Address Format Notes
Channel Channel 0-5 D Floating
Note: Channel 0-5 data type is floating.
Cable Diagram
HMI terminal
9pin D-SUB female/male
Controller
com0/com1 RS485 terminal
1 RX- DATA-
6 RX+ DATA+
AysjNet
Serial Communication
Series CPU Link Module Driver
Compressor Controller KYK3-K RS485 on port AysjNet
System configuration
Series CPU Link Module COMM Type Parameter Cable
Compressor
Controller KYK3-K RS485 on port RS485 Setting Your owner cable
Communication Setting
28
CORO VISION
Supported Device
Device Bit Address Word Address Format Notes
Cable Diagram
Serial Communication
Series CPU Link Module Driver
NextMove ES NextMove ES RS232 on the CPU unit Baldor NextMove ES
System configuration
Series CPU Link Module COMM Type Parameter Cable
NextMove ES NextMove ES RS232 on the CPU unit RS232 Setting Your owner cable
29
CORO VISION
Communication Setting
30
CORO VISION
Supported Device
Only data of comms can be monitored, some address greater than or equal to 100 are read only. Please pay
attention to matching the controller software configuration.
Device Bit Address Word AddressParameter symbol Format Notes
Float 1-255 DDD Float Data type
Cable Diagram
RS232 communication cable of HMI connecting to controller
31
CORO VISION
Barcode
Serial Communication
Series CPU Link Module Driver
Barcode 3800LTP-12E RS232 Barcode
System configuration
Series CPU Link Module COMM Type Parameter Cable
Barcode 3800LTP-12E RS232 RS232 Setting Your owner cable
Communication Setting
Supported Device
Device Bit Address Word Address Format Notes
Word LW 0-8999 DDDD
Word LW 9000 DDDD
Note: 1. LW0-8999: the character after scanning, text and note book parts can display it.
2. LW9000: the state of barcode is received or not. LW9000=1 means the data is
received.
Cable Diagram
Connect the scanner and the COM port of HMI directly.
32
CORO VISION
Baumuller
Serial Communication
Series CPU Link Module Driver
Baumuller BM4413-ST0-02200-03 RS422 on the CPU unit Baumuller
System configuration
Series CPU Link Module COMM Type Parameter Cable
Communication Setting
Supported Device
Device Bit Address Word Address Format Notes
Bit type DB_BIT000-255F DDD.H
Word type DB0-255 DDD
Example: DB2_BIT address please input 0.F in the EV5000 software.
DB2 address please input 11 in the EV5000 software.
Cable Diagram
RS485-4 communication cable
33
CORO VISION
HMI terminal
9pin D-SUB female\male
Controller terminal
com0/com1 9 pin D-SUB (male)
9 TXD+ 6 RXD+
4 TXD- 5 RXD-
6 RXD+ 9 TXD+
1 RXD- 1 TXD-
5 GND 3 GND
Serial Communication
c CPU Link Module Driver
KVFC+ RS485 Bosch Rexroth KVFC+
System configuration
Series CPU Link Module COMM Type Parameter Cable
KVFC+ RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
Supported Device
Device Bit Address Word Address Format Notes
STW0 open, start.
Start/Stop STW0~3 D
STW0 close, stop.
34
CORO VISION
Cable Diagram
Bosch Rexroth
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COMM Type Parameter Cable
PPC-R22.1 RS232 on the CPU unit RS232C Setting Your owner cable
PPC-R
13VRS RS485 on the port RS485 Setting Your owner cable
L L40
RS232 on the CPU unit RS232C Setting Your owner cable
L20
35
CORO VISION
Communication Setting
PPC-R communication setting
RS232 communication: 19200, 8, even, 1; station number: 128
RS485 communication
Note: To communicate with the touch screen, declare variable firstly in the Rexroth software.
36
CORO VISION
Note: To communicate with the touch screen, declare variable firstly in the Rexroth software.
L40 Hardware Settings
37
CORO VISION
38
CORO VISION
4. Click online/login
L40 software setting
1) The IndraLogic software connect with the Rexroth IndraControl L40 by ethernet cable test: plc
IP address192.168.100.103
Open the IndraLogic softwarecreate a new project
39
CORO VISION
40
CORO VISION
At the same time, you will find that there automatically generate two variables in the global
variable
41
CORO VISION
42
CORO VISION
Note The PLC panel must be set up, press Enter, then press, until showed up RS232, and
then press Enter to enter COM SERV interfaces (not SERV, it must change to SERV)
In accordance with the above settings, the serial line access, EV5000 can be communicated with
the Rexroth Controller L40 by serial port.
Supported Device
Device Bit Address Word Address Format Notes
BYTE B0000-9999 DDDD
WORD W0-65535 DDDDD
INT I0-65535 DDDDD
UINT UI0-65535 DDDDD
DWORD DW0-65535 DDDDD
DINT DI0-65535 DDDDD
UDINT UD0-65535 DDDDD
Cable Diagram
PPC-R RS232 communication cable
43
CORO VISION
System configuration
Series CPU Link Module COMM Type Parameter Cable
IndraLogic L40 DPM 02VRS ETH on the CPU unit ETH Setting Your owner cable
Communication Setting
Network communication
Project construction
HMI Attribute
44
CORO VISION
Network configuration Note: PLC port num. must be set 6042HMI port num. is
optional default is 6042. In addition, the screen and plc must be set in the
same network segment, the gateway of the screen is better to set with the
actual use of the network gateway .
45
CORO VISION
Note: To communicate with the touch screen, declare variable firstly in the Rexroth software.
46
CORO VISION
3. Click online/login
Supported Device
Device Bit Address Word Address Format Notes
BYTE B0000-9999 DDDD
WORD W0-65535 DDDDD
INT I0-65535 DDDDD
UINT UI0-65535 DDDDD
DWORD DW0-65535 DDDDD
DINT DI0-65535 DDDDD
UDINT UD0-65535 DDDDD
Cable Diagram
Cross-connection or crossover network cable can be used as communication cable via the hub
a. Cross-connection cable diagram:
47
CORO VISION
System configuration
Series CPU Link Module Parameter Cable
KINCO K4
CAN port on the External Device Setting
Other company devices which Your owner
support CANOpen CAN port Setting cable
Communication Setting
48
CORO VISION
HMI
Note: Baud Rate and Station No. must be the same as the setting in the controller.
PLC setting
Note: you can find MT5020.EDS in fieldbus file of EV5000 Installation Directory, or you can
download from www.kinco.cn.
Take MT6000 for example (we use MT6000 HMI to test, and use 3S CODESYS software to
download project)
1. Setup
Start Menu 3s Software->Codesys v2.3->installtarget
49
CORO VISION
50
CORO VISION
51
CORO VISION
52
CORO VISION
53
CORO VISION
Supported Device
Device Bit Address Word Address Format Notes
LW8000~LW8999 DDDD
Note: we must make the setting of PD0, SD0 and LW the same as codesys
Cable Diagram
54
CORO VISION
Danfoss Inverter
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COMM Type Parameter Cable
Danfoss FC-300 RS485 on the CPU unit RS485-2 Setting Your owner cable
Modbus RTU FC-300 RS485 on the CPU unit RS485-2 Setting Your owner cable
Communication Setting
Danfoss Protocol:
55
CORO VISION
Note Change the value of 8-30 to 2 on the Danfoss Frequency Converter for modbus protocol
Change the value of 8-30 to 0 for the Danfoss Protocol
Frequency Converter
8-3* FC Port Setting
8-30 protocol
*[0] FC (danfoss protocol)
[2] Modbus (modbus protocol)
8-31 address
1 - 247 * 1 (HMI station No.)
8-32 FC Port Baud Rate
[0] 2400 Baud
[1] 4800 Baud
*[2] 9600 Baud
8-33 FC Port Parity
*[0] even, 1 stop bit
[1] Odd, 1 stop bit
[2] None, 1 stop bit
[3] None, 2 stop bit
Supported Device
Danfoss Protocol:
Device Bit Address Word Address Format
EEPROM Register(Double Word) EPD0-7998.99999 DDDD.DDDDD
56
CORO VISION
57
CORO VISION
Control word RW1: While RW1=0x47C or 1148, it means start. While RW=0x0F03 or 3843, it
means stop.
Frequency of RW0 mapping : If input 2000 to RW0, frequency is 25HZ, and input 4000,
frequency is 50HZ, and so on.
Timer, send value of RW1 and RW0 to RWD8000.
58
CORO VISION
In addition, to get mapping address of startup, you should set bit of 3, 4, 5, 6,7,11 coil on:
0x047C=0000 0100 0111 1100
Set 0X 3, 0X 4, 0X 5, 0X 6, 0X 7, 0X 11 all to 1 (if random one of these registers is 0,
Frequency Converter will stop.
loop 0 1
01 Preset reference value LSB
02 Preset reference value MSB
03 DC brake Do not DC brake
04 Inertial stop Do not Inertial stop
05 Quickly stop Do not Quickly stop
06 locking frequency Do not locking frequency
07 Acc/Dec stop start
08 Do not reset reset
09 Do not inching inching
10 Acc/Dec 1 Acc/Dec 2
11 valid data invalid data
12 Relay 1 close Relay 1 open
13 Relay 2 close Relay 2 open
14 Set LSB
15 Set MSB
16 Do not reverse reverse
Transducer controller word (FC structure)
59
CORO VISION
Set 0X 30X 40X 50X 60X 7 all to 1 via the method of setting on when window open; One
switch control 0X11 to 1 or 0, mapping Frequency Converter to start or stop.
0x2000=0010 0000 0000 0000(binary bit from the 17th to the 32nd), setting the 30th bit to 1
means frequency is 25Hz, and 1 in the 29th bit means 12.5Hz, and so on. In short, the
0X17~0X32 is to control frequency. The Frequency Converter will show the value after starting.
0X17~0X32 for controlling frequencymapping as follows:
0x4000 50Hz
0x2000 25Hz
0x1000 12.5Hz (approximate)
0x800 6Hz
And so on, about 80 times
Cable Diagram
60
CORO VISION
HMI terminal
9pin D-SUB female\male Controller
RS485 terminal
com0/com1
1RX- 69
6RX+ 68
5 GND 61
Delta
Corporation
Serial Communication
Series CPU Link Module Driver
DVP14SS11R2
DVP 24 RS232 on the CPU unit
DVP DVP 32 Delta DVP
DVP 60ES00 RS485 on port
DVP-XXES01
System configuration
Series CPU Link Module COMM Type Parameter Cable
DVP14SS11R2
DVP 24 RS232 on the CPU unit RS232 Setting Your owner cable
DVP DVP 32
DVP 60ES00
RS485 on port RS485-2 Setting Your owner cable
DVP-XXES01
Communication Setting
DVP RS232 communication
61
CORO VISION
Note: if we use RS485 communication, we should change the value of D1120 in the PLC
Software.
PLC setting
1. Wpl207->Auxiliary Editing->RS-485 Protocol Setting (D1120), you can set the value of D1120.
62
CORO VISION
2. when PLC and Wpl207 are connective, change D1120. for example, 9600 7 even 1.and then
D1120=86HEX
Supported Device
Device Bit Address Word Address Format Notes
Input X0-9999 OOOO
Output Y0-9999 OOOO
Auxiliary Relay M0-9999 DDDD
Step Relay S0-9999 DDDD
Timer Relay T0-9999 DDDD
Counter Relay C0-9999 DDDD
Timer TV0-9999 DDDD
Counter CV0-127 DDD
Double word counter CV2 232-255 DDD
Data Register D0-9999 DDDD
Cable Diagram
DVP RS232 communication cable
63
CORO VISION
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COMM Type Parameter Cable
DVP DTA4848 RS485 on port RS485-2 Setting Your owner cable
DTB9696VR RS485 on port RS485-2 Setting Your owner cable
Communication Setting
RS485-2 communication
Supported Device
64
CORO VISION
Controller Setting
1. Set the communication parameter right
Setting communication parameter in setting mode
(2) (Baudrate)
(4) (Parity)
4703H Lower-limit alarm 1 In the running mode , when ALA1 is 1 and Lower
-limit alarm is valid.
4705H Lower-limit alarm 2 In the running mode , when ALA2 is 2 and Lower
-limit alarm is valid.
4706H Upper-limit of temperature range The data content should not be higher than the temperature
65
CORO VISION
4719H Control Run/Stop setting Run: 1 (default), Stop: 0. in the running mode
66
CORO VISION
1004H Input temperature sensor type Type and Temperature Range for detail. In the setting
mode
0: PID, 1: ON/OFF, 2: manual tuning, 3: PID grogram
1005H Control method
control. In the setting mode
0: Heating, 1: Cooling, 2: Heating/Cooling, 3:
1006H Heating/Cooling control selection
Cooling/Heating. In the setting mode
67
CORO VISION
1016H Temperature regulation value -99.9 ~ +99.9, unit: 0.1. in the adjusting mode
1019H Dead Band setting of valve 0 ~ 100%; unit: 0.1%. in the adjusting mode
68
CORO VISION
2080H~ Pattern 0~7 execution time Time 0 ~ 900 (1 minute per scale). in the setting mode
20BFH setting(Pattern 0 time is set to
2080H~2087H) ~
DTB9696VRAddress and Content of Bit Register (corresponds to 1X in the HMI)
69
CORO VISION
mode
0812H Decimal point position selection Except for the thermocouple B, S, R type, all the
other thermocouple type are valid. (0 or 1).
Cable Diagram
DVP RS485-2 communication cable
70
CORO VISION
D3CellTM
Serial Communication
Series CPU Link Module Driver
D3CellTM D3CellTM RS422 on the CPU unit DLoadCell
System configuration
Series CPU Link Module COMM Type Parameter Cable
D3CellTM D3CellTM RS485 on the CPU unit RS422 Setting Your owner cable
Supported Device
For detailed device, please refer to the PLC manual.
Communication Setting
Cable Diagram
71
CORO VISION
EB-MOD2P-01(Bus Bridge)
Serial Communication
Series CPU Link Module Driver
RS232 on the CPU unit
FieldBus Bridge EB-MOD2P-01 RS485 on the CPU unit EB-MOD2P-01
RS422 on the CPU unit
System configuration
Series CPU Link Module COMM Type Parameter Cable
FieldBus RS232 on the CPU unit RS232 Setting Your owner cable
Bridge EB-MOD2P-01 RS422 on the CPU unit RS422 Setting Your owner cable
RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
EB-MOD2P-01 RS232 communication
72
CORO VISION
Supported Device
EB-MOD2P-01
Device Bit Address Word Address Format Notes
Internal/External Output bit 0X1-60 DDDDD
Internal/External Input bit 1X1-60 DDDDD
Data Register bit 3X_bit1-60 DDDDD
Data Register bit 4X_bit1-60 DDDDD
Simulate Input Register bit 3X1-60 DDDDD
Data Register 4X1-60 DDDDD
Data Register 5X1-60 DDDDD
Data Register 6X1-60 DDDDD
Data Register 3X-DINV 1-60 DDDDD
Data Register 4X-DINV 1-60 DDDDD
73
CORO VISION
Note The correspondence between the device of EV5000 and the s7-300 software, as follows:
4X-DINV------------PID
e.g.4X-DINV1------------PID256 4X-DINV3------------PID260
3X-DINV------------PQD
e.g. 3X-DINV1------------PQD256 3X-DINV3------------PQD260
4X -------------------PIW
e.g. 4X1 --------------------PIW256 4X2--------------------PIW258
3X--------------------PQW
e.g. 3X1---------------------PQW256 3X2---------------------PQW258
0X--------------------I
e.g.0X1--------------------I0.0 0X9--------------------I1.0
1X--------------------Q
e.g.1X1--------------------Q0.0 1X9--------------------Q1.0
4X_BIT -------------------PIWbinary
e.g. 4X_BIT1.0~~1.15-------------------PIW256 binary
3X_BIT--------------------PQWbinary
e.g. 3X_BIT1.0~~1.15--------------------PQW256binary
Project configuration
1 Use the guide to set up projects in the s7-300 software.
2Double click DP of "HW Config"->attribute->new
74
CORO VISION
Note: the address of DP cant be the same as MPIs .Double click the address number to change
it.
4Double click GATEWAY"->"eview"->"B_MO1"to extend device.
75
CORO VISION
Note: for project configuration of BRIDGE, you must configure DI/D0 resource of 12 bytes firstly.
AI/AO is optional.
5 Must Use OB82,OB86,OB100,OB121,OB122 in the ladder program of the external
device, otherwise you need to manually operate the RUN switch of the external device as
RUN,STOP,RUN in this order upon restart the display or PLC. When you use those special OB
block, the communication will be automatically recovered even if you restart the display or PLC.
6 Save and compile, and download to module, then the light of profibus is on.
7After configuration, and then you can program.
Bus Bridge setting:
1Setting ID of Profibus by switching 8-bit Dip(DIP1 is lowest bit, DIP8 is highest bit),range is
from 3 to 125;
ID must be the same as its configuration in Siemens software. As above picture for example,
setting is 3, that the switch DIP1 and DIP2 on the panel of profibus are set ON, others are OFF.
2Profibus support baudrate as follows: 9.6Kbit/s, 19.2Kbit/s, 45.45Kbit/s, 93.75Kbit/s,
187.5Kbit/s, 0.5Mbit/s, 1.5Mbit/s, 3Mbit/s, 6Mbit/, 12Mbit/sand interface is automatically adaptive.
3A cable (purple),connect DP interface of s7-300 and bus bridge of profibus. Two sides
have active terminal resistors; Switch on the s7-300 PLC is off, on the busbridge is on.
4Setting baudrate of modbus by switching DIP1-3 of modbus ID port, support 8 kinds of
baudrate .Setting as follows:
1 2 3 Baud
OFF OFF OFF 1200
ON OFF OFF 2400
OFF ON OFF 4800
ON ON OFF 9600
OFF OFF ON 19200
76
CORO VISION
ON OFF ON 38400
OFF ON ON 57600
ON ON ON 115200
5Setting station number of modbus by switching DIP4-8 of modbus ID port ,support 1 to 30 kinds
of station number(DIP4 is lowest bit,DIP8 is highest bit, if DIP4 is on and DIP5~8 is off, it means
station number is 00001,that is No. 1 station).
Cable Diagram
RS232 communication cable
HMI terminal
9pin D-SUB female\male
Controller Modbus terminal
com0/com1 9 pin D-SUB (male)
1 RD- 6 TD-
4 TD- 8 RD-
5 GND 5 GND
6 RD+ 1 TD+
9 RD+ 9 RD+
77
CORO VISION
ENDA
Serial Communication
Series CPU Link Module Driver
ELC RS485-2 on the CPU unit
ETC RS485-2 on the CPU unit
ENDA devices EUC RS485-2 on the CPU unit ENDA Controller/PLC Devices
EPC RS485-2 on the CPU unit
EDP RS485-2 on the CPU unit
System configuration
Series CPU Link Module COMM Type Parameter Cable
ELC RS485-2 on the CPU unit RS485
ETC RS485-2 on the CPU unit RS485
ENDA
EUC RS485-2 on the CPU unit RS485 Setting Your owner cable
devices
EPC RS485-2 on the CPU unit RS485
EDP RS485-2 on the CPU unit RS485
Communication Setting
ENDA Devices:Default communication:9600, 8, 1, none; station1
Supported Device
ENDA PLC Devices
Device Bit Address Word Address Format Notes
Output Relay MB 0-65535 DDDDD
Input Relay (read only) IP 0-65535 DDDDD
78
CORO VISION
Cable Diagram
RS485 communication cable
Serial Communication
Series CPU Link Module Driver
Emerson Ec10 Ec10-1006BRA RS232 on the CPU unit Emerson EC10
Emerson Ec20 Ec20-2012BRA
RS232 on the CPU unit Emerson EC20
Ec20-3232BRA
System configuration
Series CPU Link Module COMM Type Parameter Cable
Emerson RS232 on the CPU unit RS232 Setting Your owner cable
Ec10-1006BRA
Ec10 RS485 on port1 RS485-2 Setting Your owner cable
Ec20-2012BRA RS232 on the CPU unit RS232 Setting Your owner cable
Emerson
RS485 on port1 RS485-2 Setting Your owner cable
Ec20 RS232 on the CPU unit RS232 Setting Your owner cable
Ec20-3232BRA
RS485 on port1 RS485-2 Setting Your owner cable
Communication Setting
79
CORO VISION
80
CORO VISION
Note: Communication with port1, you must set the system configuration in the programming
software first.
Supported Device
81
CORO VISION
Emerson Ec10
Device Bit Address Word Address Format Notes
Output Relay X000-377 OOO
Input Relay Y000-377 OOO
Internal Relay M0000-1999 DDDD
Special Relay SM000-255 DDD
Step Relay S000-991 DDD
Timer Relay T000-255 DDD
Counter Relay C000-255 DDD
Data register D0000-7999 DDDD
Special Register SD000-255 DDD
Index Register Z00-15 DD
Timer T000-255 DDD
Counter C000-199 DDD
Counter(double word) C_Double200-255 DDD
Data register(double word) D_Double0000-7999 DDDD
Special Register(double word) SD_Double000-127 DDD
Emerson Ec20
Device Bit Address Word Address Format Notes
Output Relay X000-377 OOO
Input Relay Y000-377 OOO
Internal Relay M0000-1999 DDDD
Special Relay SM000-255 DDD
Step Relay S000-991 DDD
Timer T000-255 DDD
Counter C000-255 DDD
Data register D0000-7999 DDDD
Special Register SD000-255 DDD
Index Register Z00-15 DD
Timer T000-255 DDD
Counter C000-199 DDD
Counter(double word) C_Double200-255 DDD
Data register(double word) D_Double0000-7999 DDDD
Special Register(double word) SD_Double000-125 DDD
Cable Diagram
Emerson RS232 communication
82
CORO VISION
Epower
Serial Communication
Series CPU Link Module Driver
EPower
Epower Epower CPU Direct
Epower Slave
System configuration
Series CPU Link Module COMM Type Parameter Cable
Setting Your owner cable
Epower Epower CPU Direct RS232
Setting Your owner cable
Communication Setting
83
CORO VISION
Supported Device
Device Bit Address Word Address Format Notes
84
CORO VISION
Cable Diagram
COM0 connect to ups communication board
Serial Communication
Series CPU Link Module Driver
Eview Master Eview Master
Eview Slave Eview Slave
System configuration
Series CPU Link Module COMM Type Parameter Cable
Eview Master Setting Your owner cable
Eview Slave Setting Your owner cable
85
CORO VISION
Supported Device
Device Bit Address Word Address Format Notes
B0 - 8999 DDDD
W0 - 8999 DDDD
Communication Setting
EVIEW MASTER
EVIEW SLAVE
Cable Diagram
86
CORO VISION
Facon Corporation
Serial Communication
c CPU Link Module Driver
FBs-10MA/MC RS232 on the CPU unit Port 0
FBs-14MA/MC Port 1
FBS-CB25-3
FBs-20MA/MC Port 2
FBs-24MA/MC
FBs-32MA/MC
FBs
FBs-40MA/MC
FBs-60MA/MC
FBs-20MN
FBs-32MN
Facon FB
FBs-44MN
Modbus RTU
FBe-20MA
FBe-28MA CPU unit Port 0
FBe-40MA
FBe-20MC Port 0
FBe/FBn FBe-28MC CPU unit Port 1
FBe-40MC Port 2
FBn-19MCT
FB-DTBR
FBn-26MCT
FBn-36MCT FB-DTBR-E
System configuration
Driver Series CPU Link Module COMM Type Parameter Cable
RS232 on the CPU
RS232 Setting Your owner cable
FACON FB MA unit
FBs-20MAT
FB FB MC RS232 Setting Your owner cable
FBS-CB25-3
RS485 Setting Your owner cable
Modbus FB MA RS232 Setting Your owner cable
RTU FB MC FBs-20MAT FBS-CB25-3
RS485 Setting Your owner cable
87
CORO VISION
Communication Setting
FACON FB RS232 communication
88
CORO VISION
Note: The detailed communication configuration must be the same as the PLCs port setting.
Supported Device
Device Bit Address Word Address Format Notes
89
CORO VISION
Cable Diagram
FB RS232 communication cable
HMI terminal
9pin D-SUB female/male
Controller terminal
com0/com1 com2 15 pin D-SUB (male)
2 RX 7 RX 2 TXD
3 TX 8 TX 1 RXD
5 GND 5 GND 6 GND
1 RXD
6 GND
FBS-CB25-3 module communication
RS232 communication cable
HMI terminal
9pin D-SUB female/male
Controller port1
com0/com1 terminal
2RXD 9 pin D-SUB (male)
3TXD 2TXD
3RXD
5GND 5SG
7RTS 7CTS
8CTS 8RTS
90
KINCO
Fuji SPB
Serial Communication
Series CPU Link Module Driver
SPB NW0P20T-31 RS485 interface on the CPU
NB NB2U24R-11 Fuji SPB
RS485 interface on the CPU
System configuration
Series CPU Link Module Ethernet Type Parameter Cable
SPB NW0P20T-31 RS485 interface on the CPU RS485-4
NB NB2U24R-11 RS485 interface on the CPU RS485-4 Setting Your owner cable
Communication Setting
Note When PLC is protected by password, protocol time out is 65535, and the register is read
only. If you want to make the register writable, you must let the protocol time out 2 equal the PLC
password.
Example: PLC password is 1234, and then you make the protocol time out 2 to be 1234.
PLC password is 0010, and then you make the protocol time out 2 to be 10.
91
KINCO
Supported Device
SPB
Device Bit Address Word Address Format Notes
NB
Device Bit Address Word Address Format Notes
92
KINCO
Cable Diagram
Serial Communication
Series CPU Link Module Driver
IC693CPU311
IC693CPU313
IC693CPU321
IC693CPU323
IC693CPU331
IC693CPU340
IC693CPU341
IC693CPU350
93
KINCO
IC693CPU340
IC693CPU341
IC693CPU350
IC693CPU360
IC693CPU364
Connector on Power Supply
IC693CPU351
Port1 on CPU unit
IC693CPU352
Port2 on CPU unit
IC693CPU363
IC693CMM311
System configuration
Series CPU Link Module COMM Type Parameter Cable
Your owner
RS232 Setting
RS485 on the cable
CPU unit Your owner
RS485-4 Setting
GE Fanuc Series cable
90-30 IC693CPU374 Your owner
RS232 Setting
cable
IC693CMM311
Your owner
RS485-4 Setting
cable
Your owner
RS232 on port1 RS232 Setting
CPU001/002/005 cable
VersaMax Series
CPUE05 Your owner
RS485 on port2 RS485-4 Setting
cable
IC200UAL004/005/006 Your owner
RS232 on port1 RS232 Setting
IC200UDD110/120/212 cable
VersaMax Micro
IC200UDR005/006/010
& Nano Series Your owner
IC200UAA007 RS485 on port2 RS485-4 Setting
cable
IC200UAR028
Communication Setting
GE Fanuc Series SNP RS232 Communication
94
KINCO
95
KINCO
Supported Device
Device Bit Address Word Address Format Notes
System SC01-32 DD
System SB01-32 DD
System SA01-32 DD
System S01-32 DD
Temporary T001-256 DDD
96
KINCO
Cable Diagram
GE Fanuc Series SNP RS232 communication
The communication cable recommended by GE Fanuc Automation
VersaMax series RS232 communication
HMI terminal
9pin D-SUB female/male Controller VersaMax terminal
com0/com1 com2 9 pin D-SUB (male)
2 RX 7 RX 2 TX
3 TX 8 TX 3 RX
5 GND 5 GND 5 GND
97
KINCO
HAIWELL
Serial Communication
Series CPU Link Module Driver
RS232 on com1
E/S HW-S16ZA220R Haiwell
RS485 on com2
System configuration
Series CPU Link Module COM Type Parameter Cable
98
KINCO
Communication Setting
Haiwell RS232 communication
Supported Device
Device Bit Address Word Address Format Notes
99
KINCO
Cable Diagram
Haiwell RS232 communication cable
HanG
Serial Communication
Series CPU Link Module Driver
HanG DTS3338 RS485 on the CPU unit HanG
System configuration
Series CPU Link Module COMM Type Parameter Cable
HanG DTS3338 RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
100
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Password APAS 0 H
Meter Number ANUM C032 HHHH.H
Init Meter ASTR 0 H
Register value AMVD 9010 HHHH
NoteUse text part to show meter number (ANUM). AMVD data type: signed integer
Cable Diagram
HMI terminal
9pin D-SUB female/male Controller
RS485 terminal
com0/com1
1RX- 10 B
6RX+ 10 A
Hitachi Inverter
Serial Communication
Series CPU Link Module Driver
Hitachi Inverter SJ300 RS485-2 Hitachi SJ300
System configuration
101
KINCO
Communication Setting
HMI default communication parameter: 4800, 7, none, 1; station: 1
Supported Device
Device Bit Address Word Address Format Notes
102
KINCO
Cable Diagram
RS485-2 communication cable
HMI terminal
9pin D-SUB female/male
Controller
com0/com1 RS485 terminal
1RX- SN
6RX+ SP
Serial Communication
Series CPU Link Module Driver
H Hitachi
H-20 port on CPU
H-28
H-40
H-64
H-200(CPU-02H)
103
H-250(CPU21-02H)
KINCO
H-252B(CPU22-02HB)
H-252C(CPU22-02HC)
H-300(CPU-03Ha)
H-302(CPU2-03H)
H-700(CPU-07Ha)
H-702(CPU2-07H)
H-2000(CPU-20Ha)
H-2002(CPU2-20H)
H-4010(CPU3-40H)
H-1002(CPU2-10H)
H-300(CPU-03Ha)
H-302(CPU2-03H)
H-700(CPU-07Ha) COMM-H
H-702(CPU2-07H) COMM-2H
H-2000(CPU-20Ha)
H-2002(CPU2-20H)
H-4010(CPU3-40H)
H-1002(CPU2-10H) COMM-2H
EH-150(EH-CPU104)
EH-150(EH-CPU104A)
EH-150(EH-CPU208)
EH-150(EH-CPU208A)
EH-150(EH-CPU308)
EH-150(EH-CPU308A) Serial port 1 on CPU
EH-150(EH-CPU316) Serial port 2 on CPU
EH-150
EH-150(EH-CPU316A)
EH-150(EH-CPU448)
EH-150(EH-CPU448A)
EH-150(EH-CPU516)
EH-150(EH-CPU548)
EH-150(EH-CPU516) Port 1 on EH-SIO
EH-150(EH-CPU548) Port 2 on EH-SIO
MICRO-EH(EH-D10)
MICRO-EH(EH-A14)
MICRO-EH(EH-D14)
MICRO-EH MICRO-EH(EH-A23) Port 1 on CPU
MICRO-EH(EH-D23)
MICRO-EH(EH-A28)
MICRO-EH(EH-D28)
MICRO-EH(EH-A23)
MICRO-EH(EH-D23)
MICRO-EH(EH-A28) Port 2 on CPU
MICRO-EH(EH-D28)
MICRO-EH(EH-A64) Port on CPU
104
KINCO
MICRO-EH(EH-D64)
MICRO-EH(EH-A40)
MICRO-EH(EH-D40) EH-OB232
MICRO-EH(EH-A20) EH-OB485
MICRO-EH(EH-D20)
System configuration
Series CPU Link Module COMM Parameter Cable
Type
RS232 on the CPU
H H-20 RS232
unit
Serial port 1 on CPU
EH-150 EH-150(EH-CPU104)
Serial port 2 on CPU
Port 1 on CPU RS232 Setting Your owner cable
MICRO-EH EH-A23DR
Port 2 on CPU RS485 Setting Your owner cable
Communication Setting
RS232 communication
RS422 communication
105
KINCO
Supported Device
Hitachi EH-A23DR
Device Bit Address Word Address Format Notes
106
KINCO
Note:
1. Communication setting
EH series, only port1 supports procedure 2.Switch DIP and change special Internal Input
(WR) value to select procedure.
EH150 seriesonly EHCPU***A/448/516/548 support procedure 2. EH
PLC connect with PC only by procedure 1.
2. CPU related actions
EH150
DIP 5 must be set on.
If DIP 5 is on, which procedure (1 or2) to use by judging the value of the WR F037.The
highest bit of WR F037 must be on, so that the other bits can be written in. The data keep on,
when turn on the power again.
o By entering 0x8000, turn on the power again and value of the address is 0x0000.After
settings, communication with procedure 1.
o By entering 0xC000, turn on the power again and value of the address is 0x4000.After
settings, communication with procedure 2.
The transmission speed of port 1 will be set with DIP 3, 4 switches
o 3 on, 4 off is 19200 bps
The transmission speed of port 2 will be set with DIP 6, PHL switches.
o 6 off, PHL on is 19200 bps
MicroEH
The transmission speed will be set with DIP switches
o SW1 on is 19200 bps
Which procedure(1 or2) to use by judging the value of the WR F01A.Different with EH150,
The highest bit of WR F01A is optional, The data will reset when turn on the power again. If the value
of R 7F6 is set on, the data of WR F01A will be stored in Flash memory.
o 0x0000 for procedure 1.
o 0x8000 for procedure 2.
Note: if procedure 2 is set and written in Flash memory, external device (only supports
procedure 1) or ladder editor will not connect with it.
Cable Diagram
Programming cable, as follow:
107
KINCO
Hollysys Corporation
Serial Communication
Series CPU Link Module Driver
LM3109 Serial port0 on CPU 485 Hollysys LM
Hollysys LM Serial port1 on CPU 232
LM3107 RS232 on CPU
108
KINCO
System configuration
Communication Setting
Hollysys LM RS232
Hollysys LM RS485
Supported Device
Device Bit Address Word Address Format Notes
Discrete inputs and image Relay I0.0-2.7 D.O
109
KINCO
Cable Diagram
Hollysys LM RS232 communication cable
HuaDA HD-JZ06
Serial Communication
Series CPU Link Module Driver
RS232 on the CPU unit HuaDA HD-JZ06\ HuaDA
HD HD-JZ06
RS485 on the CPU unit HD SLAVE
110
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
RS232 on the CPU unit RS232 Setting Your owner cable
HD HD-JZ06
RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
RS232 communication
RS485 communication
Supported Device
Device Bit Address Word Address Format Notes
HMI Internal Relay LB 0-4095 DDDD
HMI Internal register LW 0-4094 DDDD
MCU Register VB 0-4095 DDDD
111
KINCO
Cable Diagram
RS232 Port
RS485 Port
IDEC Corporation
Serial Communication
Series CPU Link Module Driver
MICRO SMART FC4A-C10R2 RS232 on the CPU unit IDEC MicroSmart
System configuration
Series CPU Link Module COMM Type Parameter Cable
MICRO
SMART FC4A-C10R2 RS232 on the CPU unit RS232 Setting Your owner cable
Supported Device
Device Bit Address Word Address Format Notes
112
KINCO
Communication Setting
Cable Diagram
Idec RS232 communication cable
HMI terminal
9pin D-SUB female/male
com0/com1 Controller terminal
1 RX- 8 pin Mini Din (male)
6 RX+ 2
8 1
3 TXD 4 RXD
2 RXD 3 TXD
4 TX- 5
5 GND 6 GND
7
KDN Corporation
Serial Communication
113
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
KDN-K3 K304-14AR RS232 on the CPU unit RS232 Setting Your owner cable
Supported Device
KDN-K3
Device Bit Address Word Address Format Notes
Discrete inputs and image Relay I0.0-7.7 D.O
Discrete outputs and image Relay Q0.0-7.7 D.O
Internal memory Relay M0.0-31.7 DD.O
Analog inputs AIW0-30 DD
Analog outputs AQW0-30 DD
Internal register VW0-4094 DDDD
Internal register(double word) VD0-4092 DDDD
Note:
1 AIW, AQW, VW, VD address must be an even number. 2
AIW and I device read only.
3 The single floating VR of PLC corresponds with the VD of the Ev5000 (choose single
floating).
Communication Setting
KDN-K3 RS232 communication
114
KINCO
Cable Diagram
RS232 communication cable
Kinco Corporation
Serial Communication
Series CPU Link Module Driver
KINCO Kinco-K306-24AR RS232 on the CPU unit KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
KINCO K306-24AR RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on the port RS485 Setting Your owner cable
Supported Device
KINCO
Device Bit Address Word Address Format Notes
Discrete inputs and image Relay I0.0-31.7 D.O
Discrete outputs and image Relay Q0.0-31.7 D.O
Internal memory Relay M0.0-31.7 DD.O
Analog inputs AIW0-62 DD
115
KINCO
Communication Setting
KINCO RS232 communication
Cable Diagram
RS232 communication cable
116
KINCO
Kinco ED Series
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COMM Type Parameter Cable
ED100 RS232 on the CPU unit RS232 Setting Your owner cable
ED RS485 on port RS485-2 Setting Your owner cable
ED200 RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on port RS485-2 Setting Your owner cable
ECOVARIO ECOVARIO RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on port RS485-2 Setting Your owner cable
Communication Setting
Ecostep RS232 communication
117
KINCO
Note: If the servo controller station has been modified, the station will take effect until the servo
has been restarted, otherwise communication fails.
Ecostep RS485 communication
Supported Device
Device Bit Address Word Address Range Notes
118
KINCO
sub-address is 06, and the number of bits is 20. The addressing diagram of the touch screen is
shown as follows:
Cable Diagram
ECOSTEP RS232 communication cable
Keyence Corporation
Serial Communication
Series CPU Link Module Driver
KV-16DT KV-16DT CPU Direct Keyence KV-16DT
119
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
KV-16DT KV-16DT CPU Direct RS232 Setting Your owner cable
KV-1000 KV-1000 CPU Direct RS232 Setting Your owner cable
Supported Device
KV-16DT
Device Bit Address Word Address Format
120
KINCO
Communication Setting
KV-16DT
KV-1000
Cable Diagram
KV-16DT RS232 communication cable
121
KINCO
Koyo Corporation
Serial Communication
Series CPU Link Module Driver
SM24-T RS232 on the CPU unit
DL06
DL105 RS232 on the port1
KOYO DL230
DIRECT DL240 Koyo Direct
DL250
RS232\RS422 on the port2
DL350
DL450
System configuration
Series CPU Link Module COMM Type Parameter Cable
SM24-T RS232 on the CPU unit RS232 Setting Your owner cable
RS485-2 Setting Your owner cable
DL05 RS232 on the port1 RS232 Setting Your owner cable
DL06 RS232 Setting Your owner cable
KOYO DL105
DIRECT DL230
DL240 RS232 on the port2
DL250 RS485-4 Setting Your owner cable
DL350
DL450
Supported Device
Device Bit Address Word Address Format Notes
Input I(X)0-477 OOO
Output Q(Y)0-477 OOO
122
KINCO
Communication Setting
123
KINCO
Cable Diagram
124
KINCO
HMI terminal
9pin D-SUB female/male Controller PORT2
15 pin SVGA terminal
com0/com1 com2
(male)
3 TX 8 TX 3 RX
2 RX 7 RX 2 TX
5 GND 5 GND 7 GND
4 RTS
5 CTS
KTC Srdlink
Serial Communication
System configuration
125
KINCO
Supported Device
Communication Setting
Cable Diagram
126
KINCO
LENZE Inverter
Serial Communication
Series CPU Link Module Driver
Lecom A/B EVF9323-EV RS232 on the CPU unit Lecom_AB
System configuration
Series CPU Link Module COM Type Parameter Cable
Lecom A/B EVF9323-EV RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on the CPU unit RS485 Setting Your owner cable
Supported Device
Refer to the PLC software for details Global drive control
Notecode_H: Data type is HEX
code_F: Data type is Floating
code_D: Data type is Decimal
Communication Setting
Lecom AB RS232 communication
127
KINCO
Cable Diagram
128
KINCO
Serial Communication
Series CPU Link Module Driver
K7M-DR10UE
K7M-DR20U LG Master KxxxS
K120S K7M-DT30U Port1 on CPU unit
LG Master K-Cnet
K7M-DT40U Port2 on CPU unit
LG Modbus RTU
K7M-DT60U
RS232 on the CPU unit LG XGT CPU Serial
XBC-DN64H
XGB RS232 on the channel1
XBC-DR32H LG XGT_Cnet Series
RS485 on the channel2
Note
1.Switch the DIP2 to be ON, DIP1 to be OFF, when you use the LG Master K-cnet and LG
Modbus Rtu drivers(It is not necessary to switch the dip for the LG Master KxxxS driver),
2. Non-support RS485 communication mode for the LG Master KxxxS driver;
3. Only Cnet protocol supports PLC station No.
System configuration
Series CPU Link Module COMM Type Parameter Cable
Port1 on CPU unit RS232 Setting Your owner cable
K7M-DR10UE
Port2 on CPU unit RS485-2 Setting Your owner cable
K120S
Port1 on CPU unit RS232 Setting Your owner cable
K7M-DR20U
Port2 on CPU unit RS485-2 Setting Your owner cable
RS232 on the CPU unit RS232 Setting Your owner cable
XBC-DN64H
XG RS232 on the channel1 RS232 Setting Your owner cable
XBC-DR32H
RS485 on the channel2 RS485 Setting Your owner cable
Communication Setting
LG Master K-cnet protocol default communication:38400, 8, none , 1; station number:1
129
KINCO
RS232 communication
RS485 communication
130
KINCO
LG XGT CPU Serial protocol default communication: 115200, 8, none, 1; station number: 0
Note: Only support 115200 buadrate for the protocol; station number disable.
RS232
RS232
131
KINCO
RS485
132
KINCO
2.Use the LG Modbus Rtu driversoftware setting as followspay attention to the parameter
133
KINCO
Supported Device
K120S K7M-DR10UE
Device Bit Address Word Address Format Notes
I/O Relay P0.0-63.f DD.H
Auxiliary Relay M0.0-191.f DDD.H
Link Relay L0.0-63.f DD.H
Keep Relay K0.0-31.f DD.H
Special Relay F0.0-31.f DD.H
Timer T0-255 DDD
Counter C0-255 DDD
Data Register D0-4999 DDDD
NOTEF address: 01 in the PLC corresponds to 0.1 in the ev5000;
F address: 2A in the PLC corresponds to 2.A in the ev5000.
Other register addresses, and so on.
134
KINCO
135
KINCO
Cable Diagram
K120S K-cnet protocol RS232 communication cable
136
KINCO
137
KINCO
Serial Communication
Series CPU Link Module Driver
CDE34.008 CDE34.008 RS232 on the CPU unit LustBus
System configuration
Series CPU Link Module COM Type Parameter Cable
CDE34.008 CDE34.008 RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Lustbus RS232 default communication: 57600, 7, even, 1; station: 1
138
KINCO
Supported Device
Refer to the Controller software for details: DriveManager for c-line drives
Cable Diagram
Lustbus RS232 communication cable
Serial Communication
Series CPU Link Module Driver
FP Tool port on the Control unit Matsushita FP
AFPG801
FP AFPG802
AFPG803
AFPG806
FP0 Tool port on the Control unit
FP1
FP-M RS232C port on the Control unit
FP2 Tool port on the Control unit
139
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
FP Tool port on the Control unit Your owner cable
AFPG801
RS232C Setting
FP AFPG802 Your owner cable
AFPG806
AFPG803
AFPG806 RS485(2 wire) Setting Your owner cable
140
KINCO
AFPE214322
Communication Setting
RS232 communication
RS485 communication
RS422 communication
141
KINCO
Supported Device
FP0-C16
Device Bit Address Word Address Format Notes
Input(X) Relay Y0.0-12.F DD.H
Output(Y) Relay X0.0-12.F DD.H
Timer(T) Relay T0-99 DD
Counter(C) Relay C100-143 DDD
R0.0-62.F DD.H
Internal Relay(R)
R900.0-903.F DDD.H
Timer/Counter set value(SV) SV0-143 DDD
Timer/Counter elapse value(EV) EV0-143 DDD
Data Register(DT) DT0-1659 DDDD
FPX
Device Bit Address Word Address Format Notes
Input(X) Relay X0.0~109.F DDD.H
Output(Y) Relay Y0.0~109.F DDD.H
Timer(T) Relay T0~1007 DDDD
Counter(C) Relay C1008~1023 DDDD
Link Relay(L) L0.0~127.F DDD.H
R0.0~255.F
Internal Relay(R) DDD.H
R900.0~911.F
Timer/Counter set value(SV) EV0~1023 DDDD
Timer/Counter elapse value(EV) SV0~1023 DDDD
Data Register(DT) DT0~32764 DDDDD
Note
1). Example: X address: 01 in the PLC corresponds to 0.1 in the EV5000; X address: 1F in the
142
KINCO
Cable Diagram
FP RS232 communication
HMI terminal Controller terminal
9pin D-SUB female/male 5 pin Mini Din (male)
3 TX 3 RXD
2 RX 2 TXD
5 GND 1 GND
RS232 communication
Tool port:
CPU port:
Module port:
RS485 communication
143
KINCO
RS422 communication
FP3 RS422 programming port:
Memory map
Serial Communication
Series CPU Link Module Driver
BMS005A-MC11 BMS005A-MC11 RS422 on the CPU unit MemoryMap(Master-Slave)
System configuration
Series CPU Link Module COMM Type Parameter Cable
144
KINCO
Your owner
BMS005A-MC11 BMS005A-MC11 RS422 on the CPU unit RS422 Setting
cable
Communication Setting
HMI
BMS005A default communication: 57600, 8, none, 1; station number: 1
Supported Device
Device Bit Address Word Address Format
LW.B 8000.0-8999.15 DDDD.DD
LW8000-8999 DDDD
Cable Diagram
Serial Communication
145
KINCO
Q00jCPU QJ71C24-R2
QJ71C24N Mitsubishi Q_QnA (Link Port)
QJ71C24N-R2
QJ71C24N-R4
RS232 on the CPU unit
QJ71C24
146
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
Fx0n RS232 on the CPU unit RS232 Setting Your owner cable
RS485 Module RS485-4 Setting Your owner cable
Fx1n RS232 on the CPU unit RS232 Setting Your owner cable
RS485 Module RS485-4 Setting Your owner cable
RS232 on the CPU unit RS232 Setting Your owner cable
Fx1s RS485 on the CPU unit RS485-4 Setting Your owner cable
RS485 Module RS485-4 Setting Your owner cable
Melsec FX RS232 on the CPU unit RS232 Setting Your owner cable
Fx2n RS485 on the CPU unit RS485-4 Setting Your owner cable
RS485 Module RS485-4 Setting Your owner cable
Fx2N-10GM RS232 on the CPU unit RS232 Setting Your owner cable
Fx2N-20GM RS485 on the CPU unit RS485-4 Setting Your owner cable
RS232 on the CPU unit RS232 Setting Your owner cable
Fx3uc RS485 on the CPU unit RS485-4 Setting Your owner cable
RS485 Module RS485-4 Setting Your owner cable
RS232 on the CPU unit RS232 Setting Your owner cable
QJ71C24
Q00jCPU QJ71C24-R2
QJ71C24N RS485-4 Setting Your owner cable
QJ71C24N-R2
QJ71C24N-R4
RS232 on the CPU unit RS232 Setting Your owner cable
QJ71C24
Q02CPU RS232 on the CPU unit RS232 Setting Your owner cable
Q02HCPU QJ71C24
Q06HCPU QJ71C24-R2
Q12HCPU QJ71C24N RS485-4 Setting Your owner cable
Q25HCPU QJ71C24N-R2
QJ71C24N-R4
Communication Setting
FX 1s protocol default communication: 9600, 7, even, 1;
station: 0 RS232 communication
147
KINCO
RS422 communication
148
KINCO
RS422 communication
149
KINCO
RS422 communication
150
KINCO
RS422 communication
151
KINCO
152
KINCO
RS485 communication
153
KINCO
154
KINCO
155
KINCO
156
KINCO
115Kbps
8 bit
1 bit
even
157
KINCO
Supported Device
Fx1s
Device Bit Address Word Address Format Notes
Counter C00-31 DD
Data register D000-255 DDD
Fx2n
Device Bit Address Word Address Format Notes
FX2N-10GM/20GM
Device Bit Address Word Address Format Notes
158
KINCO
Fx3u
Device Bit Address Word Address Format Notes
Q00jCPU
Device Bit Address Word Address Format Notes
Counter coil CC0-1023 DDDD
Counter contact CS0-1023 DDDD
Timer coil TC0-2047 DDDD
Timer contact TS0-2047 DDDD
Special link Relay SB000-7FF HHH
Link Relay B0000-1FFF HHHH
Status Relay S0000-8191 DDDD
Edge Relay V0000-2047 DDDD
Annunciator F0000-2047 DDDD
Latch relay L0000-8191 DDDD
Special internal Relay SM0000-2047 DDDD
Internal Relay M0000-8191 DDDD
Output Relay Y0000-1FFF HHHH
Input Relay X0000-1FFF HHHH
File register R000-7FF HHH
Special Link register SW0-3FF HHH
159
KINCO
Q02CPU
Device Bit Address Word Address Format Notes
160
KINCO
Cable Diagram
FX series RS232
CPU port communication
FX series programming cable using as communication cable.
communication module RS232BD communication cable
HMI terminal
9pin D-SUB female/male
Controller terminal
com0/com1 8pin Mini DIN(male)
1 RX- 4Tx-
6 RX+ 7Tx+
5 GND 3GND
4 TX- 1Rx-
9 TX+ 2Rx+
161
KINCO
HMI terminal
9pin D-SUB female/male
Controller terminal 6pin
com0/com1 Mini DIN(male)
2 RX 2 TXD
3 TX 1 RXD
4 DTR 5 DSR
5 GND 3 GND
6 DSR 6 DTR
8 CTS
Mks controller
Serial Communication
Series CPU Link Module Driver
BY125 BY125 RS232 on the CPU unit MKS
System configuration
Series CPU Link Module COMM Type Parameter Cable
BY125 BY125 RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Default communication: 9600, 7, even, 1; station: 11
162
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Relay CB 00-FF HH
Register CD00-FF HH
External Register ERCD 0000.00-FFFF.FF HHHH.HH
Note:
1 ERCD is Extended register, the four position before radix point are C1,C2,C3,C4.The two
positions after radix point are S1, S2.
2Parameter code corresponding with CD are C1,C2;
3 Parameter code corresponding with CB set to 1;Eg:Bit State Setting part, addr type
CB67, set the state to 1.
Cable Diagram
Mks controller RS232 communication cable
ModBus
Serial Communication
Series CPU Link Module SIO type Driver
163
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
Communication Setting
Modbus RTU RS232 communication:9600, 8, even, 1; station: 1
164
KINCO
165
KINCO
Supported Device
Modbus RTU
Device Bit Address Word Address Format Notes
Output Relay 0X1-65535 DDDDD
Input Relay (read only) 1X1-65535 DDDDD
Input Register (read only) 3X1-65535 DDDDD
Output Register 4X1-65535 DDDDD
Modbus ASCII
Device Bit Address Word Address Format Notes
Output Relay 0X1-65535 DDDDD
Input Relay (read only) 1X1-65535 DDDDD
Input Register (read only) 3X1-65535 DDDDD
Output Register 4X1-65535 DDDDD
Cable Diagram
166
KINCO
OE MAX
Serial Communication
Series CPU Link Module Driver
NX7 NX7 RS232 on the CPU unit OE MAX NX7
167
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
NX7 NX7 RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Default communication: 19200, 8, none, 1; station: 1
Supported Device
Device Bit Address Word Address Format Notes
Input/Output Relay R 0.0-127.15 DDD.DD
General Relay L 0.0-63.15 DD.DD
General Relay M 0.0-127.15 DDD.DD
Keep Relay K 0.0-127.15 DDD.DD
Timer Relay TC 0-255 DDD
Special Relay F 0.0-15.15 DD.DD
Internal HSC R_word 0-127 DDD
General Register L_word 0-63 DD
General Register M_word 0-127 DDD
Keep Register K_word 0-127 DDD
General Register F_word 0-15 DD
Timer/Counter Register SV_word 0-255 DDD
Timer/Counter Register PV_word 0-255 DDD
General Register W_word 0-2047 DDDD
Special Register SR_word 0-511 DDD
Internal HSC R_Dword 0-127 DDD
168
KINCO
Cable Diagram
Oemax RS232 communication cable
Omron Corporation
Serial Communication
Series CPU Link Module Driver
SYSMAC C CP1H CP1W-CIF01 Omron C Series Host
CP1L Link
CP1E CP1W-CIF11
Omron CP1H_CP1L
C1000HF C500-LK201-V1
C500-LK203
169
KINCO
170
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
SYSMAC CP1H CP1W-CIF01 RS232 Setting Your owner cable
C CP1L
CP1W-CIF11 RS485-4 Setting Your owner cable
CP1E
171
KINCO
Communication Setting
OMRON CP1H_CP1L default communication: 9600, 7, even, 2; station:
0 CP1W-CIF01 RS232 communication
172
KINCO
2 ON: program automaticlly transmit from card to PLC when power up OFF
OFF: program cant automaticlly transmit from card to PLC when power up
3 OFF: OFF(default) OFF
RS422 communication
174
KINCO
Note1.CJ1M switch DIP: sw1, sw2, sw3, sw5, sw8 must be off, but sw4, sw6, sw7 are optional.
2. CJ1M switches DIP 18 are OFF (default).
Supported Device
Omron SYSMAC C Series
Device Bit Address Word Address Format Notes
Latch Relay HR00.00-99.15 DD.DD
Data Memory Relay DM0000.00-6655.15 DDDD.DD
Data Link Relay LR00.00-63.15 DD.DD
Auxiliary Memory Relay AR00.00-959.15 DD.DD
Internal Auxiliary Relay CIO_IR000.00-511.15 DDD.DD
CounterCurrent Value CNT000-511 DDD
TimerCurrent Value TIM000-511 DDD
175
KINCO
OMRON CJ
Device Bit Address Word Address Format Notes
Channel I/O Relay CIO0000.00-6143.15 DDDD.DD
Internal Auxiliary Relay WR000.00-511.15 DDD.DD
Special Auxiliary Relay AR000.00-959.15 DDD.DD
Latch Relay HR000.00-511.15 DDD.DD
Timer Relay (Timer Up Flag) TIM0000-4095 DDDD
Counter Relay(Counter Up Flag) CNT0000-4095 DDDD
Data Memory DM00000.00-32767.15 DDDDD.DD
Channel I/O Register CIO0000-6143 DDDD
Internal Auxiliary Register WR000-511 DDD
Special Auxiliary Register AR000-959 DDD
Latch Register HR000-511 DDD
Timer (current Value) TIM0000-4095 DDDD
Counter (Current Value) CNT0000-4095 DDDD
Data Memory Register DM00000-32767 DDDDD
Index Register IR00-15 DD
Data Register DR00-15 DD
Cable Diagram
Omron RS232 on the CPU unit
HMI terminal
9pin D-SUB female/male Controller terminal
9pin D-SUB(male)
com0/com1 com2
3 TX 8 TX 3 RD
2 RX 7 RX 2 SD
5 GND 5 GND 9 GND
4 RTS
5 CTS
176
KINCO
Note: When connecting by the 4-wire method, set DIP1~6 to off. (The dip on the back of option
board)
Note: When connecting by the 2-wire method, set DIP1 to off, DIP 2, 3, 5, 6 to on.
Serial Communication
Series CPU Link Module Driver
OMRON E5EZ-R3 E5EZ-R3 RS485 on the CPU unit OMRON E5EZ-R3
System configuration
Series CPU Link Module COMM Type Parameter Cable
OMRON OMRON RS485 on the RS485-2 Setting Your owner cable
E5EZ-R3 E5EZ-R3 CPU unit
Communication Setting
Default communication: 9600, 7, even, 2; station: 0
177
KINCO
Supported Device
OMRON E5EZ-R3
Device Bit Address Word Address Format Notes
0.0 0.A (C0 read only) Main addr indicates variable
1.0 1.2D (C1) DDD.H type 0(C0),1(C1),2(C3)
Variable
H subaddress indicates
2.0 2.5B (C3)
address of variable type
Action Command 0-8 H
Show the bit value of 0001
State 0-31 DD
statein C0
1 Run/Stop 00 Run
01Stop
00Setting value 0
3 AT execute/stop 00stop
01AT execute
Cable Diagram
RS485-2 communication cable
OPTO 22
System configuration
Series CPU Link Module Connect Type Parameter Cable
OPTO 22 SNAP-UP1-ADS Ethernet Ethernet Setting Your owner cable
179
KINCO
Communication Setting
Network Configuration
Supported Device
Device Bit Address Word Address Format
Bit Table B0-65535 DDDDD
Bit Table BT0.000-65535.255 DDDDD.DDD
Integer 32 N32 0-65535 DDDDD
Float FN0-65535 DDDDD
UP Timer UTN0-65535 DDDDD
Down Timer DTN0-65535 DDDDD
PID parameter PIDSN0.00-32.06 DDDDD.DD
Integer 32 Table NT0.000-65535.255 DDDDD.DDD
Float Table FT0.000-65535.255 DDDDD.DDD
180
KINCO
181
KINCO
1.06 Mode
Cable Diagram
Ethernet communication cable
Cross-connection or crossover network cable can be used as communication cable via the hub
a. Cross-connection cable
Serial Communication
Series CPU Link Module Driver
Parker RS232 on CPU unit
Compax3 Parker Compax3 Parker Compax3
RS485 on CPU unit
System configuration
Series CPU Link Module COMM Type Parameter Cable
182
KINCO
Parker Parker RS232 on CPU unit RS232 Setting Your owner cable
Compax3 Compax3 RS485 on CPU unit RS485-2 Setting Your owner cable
Communication Setting
HMI
RS232 default communication: 115200, 8, none, 1; station: no address
Note: RS-485 Settings can be made in the C3 Servo Manager under RS485 settings
183
KINCO
Supported Device
Device Bit Address Word Address Format
R_Bit 0.0-9999999.31 DDDDDDD.DD
R_Float 0.0-9999.511 DDDD.DDD
R_Int 0.0-9999.511 DDDD.DDD
Note: R_Bit device is the bit format of R_Int device. The address of R_Bit device is DDDDDDD.DD, the
first seven position indicate the address of R_Int, the last two positon indicate 32-bit
Cable Diagram
RS232
RS485
184
KINCO
Serial Communication
Series CPU Link Module Driver
PC/104 PC/104 RS232 on the CPU unit PMAC series
System configuration
Series CPU Link Module COMM Type Parameter Cable
PC/104 PC/104 RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Supported Device
Device Bit Address Word Address Format Notes
185
KINCO
Cable Diagram
Serial Communication
186
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
AURO PVI-6000-OUTD-US-W RS485 on the port RS485 Setting Your owner cable
RA
Communication Setting
Default communication: 19200, 8, none, 1; station: 2
Supported Device
Device Bit Address Word Address Format
Time Registerdouble word Time 0-9999.7 DDDDD.0
Energy Registerdouble word Energy 0-9999.7 DDDDD.0
Status variable Registerdouble word Measure 0-9999.7 DDDDD.0
Hardware versiondouble word Fireware 0-9999.7 DDDDD.0
Software versiondouble word Version 0-9999 DDDD
Device sequence No.double word SN 0-9999 DDDD
Device IDdouble word PN 0-9999 DDDD
Device work status State 0-9999 DDDD
Cable Diagram
Note AURORA Wind Inverter supports two connection modes, please refer to the manual of
power-one Corporation for details.
1. Connect with RS485 port
187
KINCO
Profibus Slave
Serial Communication
Series CPU Link Module Driver
SIMATIC ALL CPUs that have PROFIBUS DP port on the
S7-300/400 the DP port External Device
Other company devices which support PROFIBUS DP port Profibus Slave
PROFIBUS DP Master
System configuration
Series CPU Link Module Parameter SIP Type
SIMATIC ALL CPUs that PROFIBUS DP port on
S7-300/400 have the DP port Setting
the External Device
Other company devices which support Profibus
PROFIBUS DP Master PROFIBUS DP port Setting
Communication Setting
188
KINCO
Note Input and Output Modules should match with Master configuration
PLC setting
Note: you can find eview.gsd in the fieldbus file of EV5000 Installation Directory, or you can
download from www.kinco.cn.
1. Setup eview.gsd file
Setup GSD file in the s7-300 software.
Process:
1. Closed all the station in HW Config
2.choose option > install GSD file.
3.Find out the folder of eview.gsd.
4 .Choose eview.gsd, and then click the install button.
You can find the ico in PROFIBUS DP\MMI, after installing
2. configuration setting
189
KINCO
190
KINCO
Note: the address No. of DP master station and slave can not be same.
5input and output setting
6 Profibus DP Slave has adaption function you can change the transmission rate of DP master station,
maximum is 12Mbps.
191
KINCO
(7) Double click slave ico, then set User_Prm_Data (0) =01
Supported Device
Device Bit Address Word Address Format Notes
Direct I/O Input LW.B8500.0~8615.F DDDD.H
Direct I/O Output LW.B8000.0~8115.F DDDD.H
192
KINCO
Cable Diagram
A-type violet cable
Serial Communication
Series CPU Link Module Driver
RF-IC RF-IC RS232 on the CPU unit RF-IC
System configuration
Series CPU Link Module COMM Type Parameter Cable
RF-IC RF-IC RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
193
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Bit LB 8999 DDDD
LW 8900 DDDD
Note: LB8999 means bar code has received or not. 1 means data has received.
Cable Diagram
Saia-Burgess
Serial Communication
Series CPU Link Module Driver
PCS PCS1.C8 RS232 on the CPU unit
PCD2.M110
PCD2.M120
PCD PCD2.M150 Saia SBus
RS232 on the CPU unit
PCD2.M170
PCD2.M480
194
KINCO
Systems Configuration
Series CPU Link Module COMM Type Parameter Cable
PCS PCS1.C8 RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on the CPU unit RS485-4 Setting Your owner cable
PCD PCD2.M110 RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Saia default communication: 9600, 8, none, 1; station:
80 RS232
RS485
Supported Device
Device Bit Address Word Address Format Notes
Input I0-8091 DDDDD
Output O0-8091 DDDDD
195
KINCO
Cable Diagram
Pcs1.c8 RS232 communication cable
Serial Communication
196
KINCO
System configuration
Series CPU Link Module COM Type Parameter Cable
Communication Setting
Sailsors D9 RS485 communication
Supported Device
Device Bit Address Word Address Format Notes
Channel Sample Value CH 0~16 DD
Channel Indexing SN 1~16 DD
Cable Diagram
Sailsors D9 RS485 communication cable
197
KINCO
Serial Communication
Series CPU Link Module Driver
TSX3705001
TSX 37 05 028DR1
TSX 37 08 056DR1
TSX 37 10 128DT1
TSX 37 10 128DR1
TSX 37 10 128DTK1
Micro TSX 37 10 164DTK1 TER port on the CPU
TSX 37 10 028AR1
TSX 37 10 028DR1
TSX 37 21 101
TSX 37 22 101
TSX 37 21 001
TSX 37 22 001 Schneider Modicon
TSX P57 103M Uni-TelWay
TSX P57 153M Modbus RTU
TSX P57 203M
Premium TSX P57 253M TER port on the CPU
TSX P57 303M
TSX P57 353M
TSX P57 453M
TSX 07 3L 28
TSX 07 30 10
Nano TSX 07 31 16
Programming port on CPU
TSX 07 31 24
TSX 07 32 28
TSX 07 33 28
TWD LCAA 10DRF
TWD LCAA 16DRF
TWD LCAA 24DRF
System configuration
Series CPU Link Driver COMM Parameter Cable
198
KINCO
Module Type
TSX3705001 RS232 Setting Your owner cable
TSX3705001
TSX 37 05 028DR1
TSX 37 08 056DR1
TSX 37 10 128DT1
TSX 37 10 128DR1
TSX 37 10 128DTK1 Schneider
RS485 on
TSX 37 10 164DTK1 Modicon
the CPU unit RS485-2 Setting Your owner cable
TSX 37 10 028AR1 Uni-TelWay
TSX 37 10 028DR1
TSX 37 21 101
TSX 37 22 101
TSX 37 21 001
Modicon TSX 37 22 001
TSX TSX3705001 RS232 Setting Your owner cable
TSX3705001
TSX 37 05 028DR1
TSX 37 08 056DR1
TSX 37 10 128DT1
TSX 37 10 128DR1
TSX 37 10 128DTK1 RS485 on Modbus
TSX 37 10 164DTK1 the CPU unit RTU RS485-2 Setting Your owner cable
TSX 37 10 028AR1
TSX 37 10 028DR1
TSX 37 21 101
TSX 37 22 101
TSX 37 21 001
TSX 37 22 001
TWD LCAA 10DRF RS232 Setting Your owner cable
TWD LCAA 16DRF
TWD LCAA 24DRF
TWD LMDA 20DTK
Twido RS485 on the CPU unit
TWD LMDA 20DUK RS485-2 Setting Your owner cable
TWD LMDA 20DRT
TWD LMDA 40DTK
TWD LMDA 40DUK
Communication Setting
Uni-TelWay protocol default communication 9600, 8, odd, 1;
station:1. RS232 communication
Note: Cable by Schneider Electric Industries, Rotary switch setting: 2(TER Direct)
199
KINCO
RS485 communication
200
KINCO
RS485 communication
PLC Setting
1. Sort menu-modicum telemecanique xway driver manager to set communication
parameter
201
KINCO
4. And then click xway testconnect, if the connection is successful, it will clue connected
202
KINCO
203
KINCO
RS485communication
204
KINCO
2. You must program a coil with maximum address to open the memory area for the Bits. If you
program a coil with 127 addresses, then the address before 127 can be used.
Supported Device
Modicon TSX
Device Bit Address Word Address Format Notes
205
KINCO
Twido
Device Bit Address Word Address Format Notes
Cable Diagram
Uni-TelWay RS232
Cable recommended by Schneider Electric Industries, Rotary switch setting: 2(TER Direct)
Add a direct line
Uni-TelWay RS485
206
KINCO
SHIMADEN FP23
Serial Communication
Series CPU Link Module Driver
FP23 FP23 RS485 on the CPU unit SHIMADEN FP23
System configuration
Series CPU Link Module COMM Type Parameter Cable
FP23 FP23 RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
RS485-2 default communication: 9600, 8, even, 1; station: 1
207
KINCO
Supported Device
Device Bit Address Word Address Format Notes
State instructions(Write Only) Ctrl_Write 184-252 HHH
Sequence code(Read Only) Array Code 0-3 H
Basic parameter valueRead Only Basic_Read 00-42 HH
OUT1_W,OUT2_W(Write Only) Out_Write 0-1 H
PV1PV2Read Only PV_Read 0-1 H
ReferenceRead & Write Reference 300-952 HHH
Basic_Read operatable address
PLC addr
HEX Parameter R/W Parameters mean
208
KINCO
Cable Diagram
FP23 programmable PID regulator of 8 point and 10 point must be shorted
or communications failure
FP23 RS485 port
209
KINCO
SIEMENS
Serial Communication
Series CPU Link Module Driver
CPU212
CPU214
CPU215
S7-200 CPU216
RS485 on the CPU unit
CPU221
Siemens S7-200
CPU222
CPU224
CPU226
S7-200 CN CPU224 XP CN
RS485 on the CPU unit
CPU226 XP CN
CPU312IFM
CPU313
CPU313C
CPU314
S7-300 CPU314IFM
MPI port on the CPU unit
CPU315
CPU315-2 DP
CPU316
CPU316-2 DP
1. Siemens S7-300/400 (PC
CPU318-2
Adapter)
CPU412-1
2. Siemens S7-300/400 (via MPI
CPU412-2 DP
port) *1
CPU413-1
CPU413-2 DP
CPU414-1
S7-400
CPU414-2 DP MPI port on the CPU unit
CPU414-3 DP
CPU416-1
CPU416-2 DP
NoteDont live plug
CPU416-3 DP
CPU417-4
SIMATIC CPU222
S7-200 CP 243-1 IT
CPU224 Siemens S7-200 Network Slave
CPU224 XP CP 243-1
210
KINCO
CPU226
211
KINCO
RS485 communication
212
KINCO
213
KINCO
214
KINCO
215
KINCO
C After Setting, download project into PLC. Make sure the MPI ports transmission rate is
187.5k, and select PC Adapter(MPI) in set PG/PC interface menu, change the transmission
rate to 187.5k, as follows:
216
KINCO
Network configuration
217
KINCO
PLC configuration
The settings for the CP 243-1 are defined in STEP 7 Micro/WIN via the Ethernet Wizard. For
assistance with all the information go to STEP 7 Micro/WIN Online Help via F1.
1. Starting the Ethernet Wizard
Open STEP 7 Micro/WIN
Start the Ethernet Wizard via Tools >Ethernet Wizard.
Click on Next
218
KINCO
3. Specifying IP address
Define an IP address for the CP 243-1.
Caution:The IP address for this application may not be taken automatically from a server because the
panel requires a fixed reference partner (CP 243-1) for the Ethernet communication.
Note: The communication connection type for this module can be defined by the Automatic Setting.
Click on Next to continue.
219
KINCO
5. Configuration connection
The configuration for connecting the CP 243-1 to the panel must be defined as in Fig..
Click OK to confirm the entries.
Warning: The TSAP must always be specified in four-digit format, with a leading zero (02.00).
220
KINCO
7. Assigning memory
Specify a memory area for the configuration of the CP 243-1.
Recommend: If you click on Suggest address, the Wizard can identify a variable memory area.
Note: The register used in the panel must be out of the memory area for the configuration.
Click on Next.
221
KINCO
9. Confirm message
Click Yes to confirm the message that appears.
Supported Device
S7-200
Device Bit Address Word Address Format
SCR S.B0.0-255.7 DDD.O
Special memory Relay SM.B0-4399.7 DDDD.O
Counter Relay Cnt0-255 DDD.O
Timer Relay Tim0-255 DDD.O
V Relay V.B0.0-32768.7 DDDDD.O
Internal Memory Relay M.B0.0-32768.7 DDDDD.O
Discrete outputs and image Relay Q.B0.0-32768.7 DDDDD.O
222
KINCO
223
KINCO
Cable Diagram
S7-200 series RS232 communication
Adapter cable by Eview Corporation direct connected with HMI is RS232 communication
S7-200 series RS485 communication
224
KINCO
If the PC Adapter with the following RS232 cable, it must add a connection line for communicating
with touch-screen
3. MPI MT5-S7-300 Adapter by Eview Corporation direct connected with HMI is RS232
communication
225
KINCO
TAIAN
Serial Communication
Series CPU Link Module Driver
RS232 on the CPU unit
Taian TOP3-30HR-A Taian
RS485 on the CPU unit
System configuration
Series CPU Link Module COMM Type Parameter Cable
Taian TOP3-30HR-A RS232 on the CPU unit RS232 Setting Your owner cable
RS485 on the CPU unit RS485 Setting Your owner cable
Communication Setting
Default communication: 19200, 8, none, 1; station: 1
226
KINCO
RS232
RS485
Supported Device
Device Bit Address Word Address Format
Input Relayreceive external
switch signal X0-377 OOO
Output Relay Y0-377 OOO
Auxiliary Relay M0-7679& (8000-8511 DDDD
Step Relay S0-4096 DDDD
Timer Relay T0-511 DDD
Counter Relay C0-255 DDD
Data Register D0-8511 DDDD
Data Register Z0-15 DD
Data Register V0-15 DD
Timer(Current value T_Current_Word 0-511 DDD
227
KINCO
Cable Diagram
TOP3-30HR-A RS232 communication cable
HMI terminal
9pin D-SUB female/male
Controller
com0/com1 RS485 terminal
1 RX- B-
6 RX+ A+
5 GND SG
TMCM_303
Serial Communication
Series CPU Link Module Driver
TMCM_303 RS232 on the CPU unit TMCM_303
System configuration
Series CPU Link Module COMM Type Parameter Cable
TMCM_303 RS232 on the CPU unit RS232 Setting Your owner cable
228
KINCO
Communication Setting
Default communication: 9600, 8, none, 1; station: 1
Supported Device
Please refer to TMCL Reference Manual for device details
TMCM_303
Device Bit Address Word Address Format Notes
229
KINCO
2.0-2.19
RFS DWord 0.0-2.2 DD.D Write Only
SIO 0-7 D Write Only
0.0-0.10
GIO 1.0-1.7 DDD.DD Read Only
2.0-2.07
CALC 0-9 D Write Only
COMP 0 D Write Only
JC 0-9 DD Write Only
JA 0 D Write Only
CSUB 0 D Write Only
RSUB 0 D Write Only
WAIT 0.0-4.7 DD.D Write Only
STOP 0 D Write Only
Cable Diagram
RS232 Communication Cable
Serial Communication
Series CPU
Link Module Driver
THINGET XC XC3-32R-E MODBUS RTU/
RS232 on the CPU unit
THINGET Controller
System configuration
Series Link Module COM Type Parameter Cable
THINGET XC RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Default communication: 19200, 8, even, 1; station: 1
230
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Internal Relay M0~M7999 DDDDD
Input Relay X0.0~X51.1 OOOOOO.O
Output Relay Y0.0~Y51.1 OOOOOO.O
State Relay S0~S1023 DDDDD
Special Relay M8000~M8511 DDDDD
Timer Relay T0~T618 DDDDD
Counter Relay C0~C634 DDDDD
Data register D0~D7999 DDDDD
Timer TD0~TD618 DDDDD
Counter CD0~CD634 DDDDD
Special Data Register D8000~D8511 DDDDD
FlashROM Register FD0~FD5000 DDDDD
Special FlashROM Register FD8000~FD8511 DDDDD
Note
1. O indicates OCT, D indicates HEX.
2. Example: X\Y address: 1 in the controller corresponds with 0.1 in the ev5000;
X\Y address: 17 in the controller correspond with 1.7 in the ev5000.
MODBUS RTU protocol
Register address in programmable controller correspond with address in modbus protocol, as
follows:
Coil Area
bits Addr MODBUS addrDecimal K
M0~M7999 0X1~0X8000
X0~X511 0X16385~0X16714
231
KINCO
Cable Diagram
XC3-32R-E RS232 Communication
Serial Communication
Series CPU Link Module Driver
232
KINCO
TRIO
Euro Euro 205x RS232 on the CPU unit
Modbus RTU Extend
System configuration
COMM
Series CPU Link Module Parameter Cable
Type
RS232 on the CPU unit RS232 Setting Your owner cable
TRIO Euro 205x
RS485 on the CPU unit RS485-4 Setting Your owner cable
Modbus
RS232 on the CPU unit RS232 Setting Your owner cable
RTU Extend Euro 205x
RS485 on the CPU unit RS485-4 Setting Your owner cable
Communication Setting
Omron Protocol default communication: 9600, 7, even, 2;
station: 1 RS232 communication
RS485-4 communication
233
KINCO
RS485-4 communication
234
KINCO
Modbus Protocol
address=1
Setcom (9600, 8, 1, 0, 1, 4)
Supported Device
TRIO
Device Bit Address Word Address Format Notes
235
KINCO
Cable Diagram
Programming Cable
Vigor Corporation
Serial Communication
Series CPU Link Module Driver
VH VH-14MR RS232 on the CPU unit
VB0 VB0-14MR Vigor
RS232 on the CPU unit
236
KINCO
System configuration
Series CPU Link Module COMM Type Parameter Cable
VH VH-14MR RS232 on the CPU unit RS232 Setting Your owner cable
VB0 VB0-14MR RS232 on the CPU unit RS232 Setting Your owner cable
Communication Setting
Default communication: 19200, 7, even, 1; station: 0
Supported Device
Device Bit Address Word Address Format Notes
237
KINCO
Cable Diagram
VH-14MR RS232 communication cable
1. Communication via USB programming port
Connection with HMI by programming cable of Vigor
XiLin Inverter
Serial Communication
Series CPU Link Module Driver
XiLin EH600 RS485-2 on the CPU unit XiLin EH600
System configuration
Series CPU Link Module COM Type Parameter Cable
XiLin EH600 RS485-2 on the CPU unit RS485-2 Setting Your owner cable
Communication Setting
RS485-2 Communication: 9600, 8, even, 1; station: 1
238
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Addr communication parameter Addr HHHH
A FWD A0 D
B REV B0 D
C FJOG C0 D
D RJOG D0 D
E Free halt E0 D
F Slow down F0 D
G Reset failures G0 D
Cable Diagram
239
KINCO
Yamatake Corporation
Serial Communication
Series CPU Link Module Driver
DCP30 P30A2 RS485 on the CPU unit Yamatake DCP30
C352
SDC35/36 C354
RS485 on the CPU unit
C362
Yamatake SDC/DMC
C364
DMC DMC10D
RS485 on the CPU unit
DMC10S
System configuration
Series CPU Link Module COMM Type Parameter Cable
C364
DMC10D RS485 on the CPU Your owner
DMC RS485 Setting
unit cable
DMC10S
Communication Setting
HMI
DC30 RS485 default communication: 9600, 8, even, 1; station: 1
SDC36 RS485 default communication: 9600, 8, none, 1; station: 1
240
KINCO
Plc
1. Set modbus RTU in the SLP-D10, and then download.
241
KINCO
Supported Device
DCP30
Device Bit Address Word AddressParameter code Format Notes
RUN Status 1-26 DDD
PARA 1-33 DDD
EU 1-13 DDD
PID 1-80 DDD
SET 1-99 DDD
TBL 1-22 DDD
CNST 1-26 DDD
FO_R 1-19 DDD
FO_W 1-19 DDD
FC 1-19 DDD
FD 1-19 DDD
FBR1_R 1.0-30.22 DDD.DD
FBR2_R 1.0-30.22 DDD.DD
FBR3_R 1.0-30.22 DDD.DD
FBR4_R 1.0-30.22 DDD.DD
FBR5_R 1.0-30.22 DDD.DD
FBR6_R 1.0-30.22 DDD.DD
FBR7_R 1.0-30.22 DDD.DD
FBR8_R 1.0-30.22 DDD.DD
FBR9_R 1.0-30.22 DDD.DD
FBR10_R 1.0-30.22 DDD.DD
FBR11_R 1.0-30.22 DDD.DD
FBR12_R 1.0-30.22 DDD.DD
FBR13_R 1.0-30.22 DDD.DD
FBR14_R 1.0-30.22 DDD.DD
FBR15_R 1.0-30.22 DDD.DD
FBR16_R 1.0-30.22 DDD.DD
FBR17_R 1.0-30.22 DDD.DD
FBR18_R 1.0-30.22 DDD.DD
FBR19_R 1.0-30.22 DDD.DD
Please refer to the communication protocol for details.
H: HEX
Note
1 SET C85 ----- Transmission rate data type
09600evenstopbit 1
19600nonestopbit 2
24800evenstopbit 1
34800nonestopbit 2.
2SET C84 -----setting station No. The value of C84 must be the same as the PLCs station No.
242
KINCO
When connecting multiple instruments, for distinguishing instruments, each instrument must be
set C84 value with a different parameter. .
3Must press FUNC+PARA to set the parameter
4PROG. have 19 numbers and SEG have 30 numbers, press DOWN key (sub) and PROG key
(add) to change program number
5 Press FUNC+PROG to change the program.----every program must be set firstly and then
communicate will be ok, or else PLC Response Error will print;
6 After RUN/HLD light on, many parameters cant be modified(e.g. SET) In order to reset, press
PROG+RUN/HOLD .
Modify the parameter at the state of DISP, not at the state of INPUT
7On the temperature controller, time parameters show number with sexagesimal.
Example it shows 2222 on the screen, but on the controller panel shows
37.02-----37.00*60+2=2222
8PROGs address setting
FBR1_R indicates prog 1. (e.g. PROG 1) format: DDD.DD. Main address DDD indicates seg No,
subaddress DD indicates parameter value, the correspondence as follows
ExampleFBR1_R address 11.10 indicates PROG 1,SEG 1,T1 2nd
DMCPlease refer to the manual of DMC-SPL for details, in 10-8 communication parameters
Device Bit Address Word Address Format Notes
243
KINCO
Cable Diagram
DC30 RS485 communication cable
244
KINCO
Yaskawa Inverter
Serial Communication
Series CPU Link Module Driver
V RS485 on the CPU unit Yaskawa AH Modbus RTU
System configuration
Series CPU Link Module COM Type Parameter Cable
V RS485 on the CPU unit RS485-2 Setting Your owner cable
Communication Setting
Default communication: 9600, 8, even, 1; station: 1
Supported Device
Device Bit Address Word Address Format Notes
Internal/external output node 0X1-65535 DDDDD
Internal/external input node 1X1-65535 DDDDD
245
KINCO
Cable Diagram
Yaskawa UDP
System configuration
Series CPU Link Module COMM Type Parameter Cable
MP series MP2400 ETH on the CPU unit ETH Setting Your owner cable
Communication Setting
Network communication
Project construction
HMI Attribute
246
KINCO
247
KINCO
248
KINCO
249
KINCO
Supported Device
Device Bit Address Word Address Format Notes
Input register node IB0000.0-FFFF.F HHHHH.H
Output register node OB0000.0-FFFF.F HHHHH.H
holding register node MB00000.0-65534.F DDDDD.H
Input register IW0000-FFFF HHHH
Output register OW0000-FFFF HHHH
Holding register MW00000-65534 DDDDD
NoteIn the EV5000 software, bit address format is HHHH.H, but there is no point in the controller.
E.g.: In the EV5000 software, the bit address is MB65534.F, but there is no point in the controller,
and it is MB65534F. We set the I\O address as large as enough, and we found the big address
cant be written, but it is the same effect with the monitoring.
Cable Diagram
Cross-connection or crossover network cable can be used as communication cable via the hub or
switch
a. Cross-connection cable diagram
250
KINCO
Serial Communication
Series CPU Link Module Driver
MP MP2300 RS232 on the CPU unit YASKAWA MP2300
System configuration
Series CPU Link Module COM Type Parameter Cable
MP MP2300 RS232 on the CPU unit RS232 Setting Your owner cable
Supported Device
Device Bit Address Word Address Format Notes
Coil MB0.0-4095.F DDDD.H
Input Relay IB 0.0-FFF.F HHHH.H
Hold Register MW 0-65534 DDDDD
Input Register IW 0-7FFF HHHH
NoteIB0.0-0.F are occupied by the system; IW0 is occupied by the system.
Communication Setting
Default communication: 19200, 8, even, 1; station: 1
251
KINCO
Cable Diagram
MP2300 RS232 communication cable
Serial Communication
Series CPU Link Module Driver
System configuration
Series CPU Link Module COM Type Parameter Cable
RS232 on the CPU unit RS232 Setting Your owner cable
/ Plus SGDM
RS422 on the CPU unit RS485-4 Setting Your owner cable
252
KINCO
Communication Setting
Default communication: 9600, 7, even, 1; station:
0 RS232 communication
RS422 communication
Supported Device
Device Bit Address Word Address Format Notes
Function Selection Basic Switches Pn000 Pn003 HHH
Speed Loop Gain and so on Pn100 Pn118 HHH
Position Control Reference Pn200 Pn205 HHH
Speed Control Reference Pn300 Pn308 HHH
Torque Control Reference Pn400 Pn407 HHH
Sequence Reference Pn500 Pn510 HHH
Other Pn600 Pn601 HHH
Monitor mode Un000 Un00D HHH
253
KINCO
Cable Diagram
RS232 communication cable
YuDian AI
Serial Communication
Series CPU Link Module Driver
AI-518
RS485 on the CPU unit YuDian AI Single_Loop
AI AI-701
AI-7048 RS485 on the CPU unit YuDian AI 4_Loop
System configuration
Series CPU Link Module COMM Type Parameter Cable
AI-518
RS485 on the CPU unit RS485 Setting Your owner cable
AI AI-701
AI-7048 RS485 on the CPU unit RS485 Setting Your owner cable
254
KINCO
Communication Setting
RS485 default communication: 9600, 8, none, 1; station: 1
SPECIAL NOTE:
For example: If station number is 2, register PV0.0 denotes channel 2, and PV1.0 denotes channel 3
(station number 2+main address 1).
Thereinto the setting of station number is very important, it denotes start address of the controller
(viz. instrument address in instrument parameter), and main address just denotes 4 channels.
When main address is 0, it denotes channel (station number+0)
Supported Device
AI-518
Device Bit Address Word Address Format
SV/STEP 0 00H DD
HIAL 1 01H -1999~+9999 DD
LoAL 2 02H -1999~+9999 DD
dHAL 3 03H 0~9999 DD
dLAL 4 04H 0~9999 DD
dF 5 05H 0~2000 DD
CtrL 6 06H 0~4 DD
M5 7 07H 0~9999 DD
P 8 08H 1~9999 DD
t 9 09H 0~2000 DD
CtI 10 0AH 0~125 DD
255
KINCO
dL 23 17H 0~20 DD
AI-701
Device Bit Address Word Address Format
HIAL 1 01H -9990~+30000 DD
LoAL 2 02H -9990~+30000 DD
HdAL 3 03H -9990~+30000 DD
LdAL 4 04H -9990~+30000 DD
AHYS 5 05H 0~2000 DD
InPRead Only 11 0BH 0~37 DD
dPt 12 0CH 0~3 DD
SCL 13 0DH -9999~+30000 DD
SCH 14 0EH -9999~+30000 DD
256
KINCO
AI-7048
Device Bit Address Word Address Format Notes
PV 0.0-3.0 D.D Read only
SV 0.0-3.0 D.D
Reference 0.0-3.86 D.D
Reference
Device Bit Address Word Address Format
SP 0 00H -1999-30000 DDD.DDD
HIAL 1 01H -1999~+9999 DDD.DDD
LoAL 2 02H -1999~+9999 DDD.DDD
3 03H DDD.DDD
4 04H DDD.DDD
AHYS 5 05H 0~2000 DDD.DDD
AT 6 06H 0~4 DDD.DDD
P 7 07H 0~9999 DDD.DDD
I 8 08H 0~9999 DDD.DDD
257
KINCO
Cable Diagram
RS485 communication cable
258