Tablas API.5l.2004
Tablas API.5l.2004
Tablas API.5l.2004
Ultimate
Yield Strength, Tensile Strength,
Elongation
Minimum Minimum
in 2 in. (50.8 mm).
Grade psi MPa psi MPa Minimum, Percent
A25 25,000 (172) 45,000 (310) a
A 30,000 (207) 48,000 (331 ) a
8 35,000 (241) 60,000 (414) a
X42 42,000 (290) 60,000 (414) a
X46 46,000 (317) 63,000 (434) a
X52 52,000 (359) 66,000 (455) a
X56 56,000 (386) 71,000 (490) a
X60 60,000 (414) 75,000 (517) a
X65 65,000 (448) 77,000 (531) a
X70 70,000 (483) 82,000 (565) a
Table F-2-Dimensions, Weights per Unit Length, and Test Pressures for TFL Pipe
Calculated
Specified Specified Plain-end Weight Calculated Minimum
Outside Diameter Wall Thickness per Unit Length Inside Diameter" Hydrostatic
D wpe d Test Pressure
Size in. mm. Grade in. mm Ib/ft kg/m m. mm psi 100 kPa b
2.375 60.3 X56 0.188 4.8 4.40 6.57 1.999 50.7 7090 492
2.875 73.0 X56 0.438 11.1 11.41 16.94 1.999 50.8 10000 689
2.875 73.0 X56 0.216 5.5 6.14 9.16 2.443 62.0 6730 465
3.500 88.9 X56 0.530 13.5 16.83 25.10 2.440 61.9 10000 689
4.000 101.6 X60 0.750 19.1 26.06 38.86 2.500 63.4 10000 689
4.000 101.6 X42 0.500 12.7 18.71 27.84 3.000 76.2 8400 579
4.000 101.6 X60 0.500 12.7 18.71 27.84 3.000 76.2 10000 689
4.000 101.6 X70 0.250 6.4 10.02 15.02 3.500 88.8 7000 486
4.500 114.3 X 52 0.750 19.1 30.07 44.84 3.000 76.1 10000 689
4.500 114.3 X70 0.281 7.1 12.67 18.77 3.938 100.1 6990 480
"The calculated inside diameters are given here for information.
b 100 kPa = I bar.
Table F-3 -Minimum All-heat Average Absorbed Energy Requirements for Stress Factor fof 0.72
(I) (2) (3) (4) (5) (6) (7) (8) (9) (10)
Minimum All-heat Average Absorbed Energy, ft-Ib (1)
Grade