Nothing Special   »   [go: up one dir, main page]

Omron E5CWL PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Temperature Controllers

E5CSL/E5CWL
The Simple and New Temperature
Controller is Released that Easily
Achieves the Temperature
Control.
Easy to Read (Character Height E5CSL: 21.7 mm
E5CWL: 16.2 mm (PV)).
Depth beyond front panel: Only 60 mm.
Fewer parameters for simple setup.
Faster sampling at 250 ms.

48 48 mm
E5CSL

48 48 mm
E5CWL

Note: Refer to Precautions on page 7.

Main I/O Functions


E5CSL/E5CWL
Single Display: E5CSL
Dual Display: E5CWL
Sensor Inputs
Thermocouple inputs
Pt inputs
Indication Accuracy
Thermocouple input: 0.5% of PV
Pt input: 0.5% of PV
Sampling Period
250 ms

4-digit Display

Alarm Outputs
One
*E5CWL only
Control Output 1
Relay output
Voltage output (for driving SSR)

Model Number Structure


Model Number Legend
Models with Single Display

Models with Dual Display

E5CSL-@@

E5CWL-@1@

1 2
1. Control Output
R: Relay output: 250 VAC, 3 A
Q: Voltage output (for driving SSR): 12 VDC, 21 mA
2. Sensor type
TC: Thermocouple (K, J, T, R, or S)
P: Platinum resistance thermometer (Pt100)

1 2 3
1. Control Output
R: Relay output: 250 VAC, 3 A
Q: Voltage output (for driving SSR): 12 VDC, 21 mA
2. Alarm (E5CWL only)
1: Relay output: 250 VAC, 1 A (resistive load)
3. Sensor type
TC: Thermocouple (K, J, T, R, or S)
P: Platinum resistance thermometer (Pt100)

E5CSL/E5CWL

Ordering Information
Single Display
Size

Power supply voltage

Input type

Alarm output

Thermocouple
1/16 DIN
48 48 60
(W H D)

100 to 240 VAC

Control output
Relay output

Resistance thermometer

None

Thermocouple

Voltage output
(for driving SSR)

Resistance thermometer

Model
E5CSL-RTC
E5CSL-RP
E5CSL-QTC
E5CSL-QP

Dual Display
Size

Power supply voltage

Input type

Alarm output

Thermocouple
1/16 DIN
48 48 60
(W H D)

100 to 240 VAC

Control output
Relay output

Resistance thermometer

Thermocouple

Voltage output
(for driving SSR)

Resistance thermometer

New model
E5CWL-R1TC
E5CWL-R1P
E5CWL-Q1TC
E5CWL-Q1P

Accessories (Order Separately)


Terminal Cover
Model

Adapter
E53-COV19

Front Panel
Model
E53-COV20
Note: 1. This Front Panel accessory is required to attach the Y92A48B or Y92A-48D.
2. This Front Panel accessory is only the frame.
It does not include the plastic cover.

Model
Y92F-45
Note: 1. Use this Adapter when the Front Panel has already been
prepared for the E5B@.
2. Only black is available.

Specifications
Ratings
Power supply voltage

100 to 240 VAC, 50/60 Hz

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

E5CSL
E5CWL

3.5 VA
Models with thermocouple inputs
Thermocouple: K, J, T, R, or S

Sensor input

Models with platinum resistance thermometer inputs


Platinum resistance thermometer: Pt100
Relay output

Control
output

3.5 VA

SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA

Voltage output
(for driving
Output voltage: 12 VDC +25%/15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
SSR)

Alarm output

SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA

Control method

ON/OFF control or 2-PID control (with auto-tuning)

Setting method

Digital setting using front panel keys

Indication method

7-segment digital display and individual indicators


Character height: E5CSL: 21.7 mm E5CWL: 16.2 mm (PV)

Other functions

Temperature input shift, run/stop, protection functions, etc.

Ambient operating
temperature

10 to 55C (with no icing or condensation)

Ambient operating humidity

25% to 85%

Storage temperature

25 to 65C (with no icing or condensation)

E5CSL/E5CWL
Input Ranges
Models with Thermocouple Inputs
Model
(temperature input)

Set value

Input type

1
2

TC input

Range
C

200 to 1,300

300 to 2,300

20.0 to 500.0

0.0 to 900.0

100 to 850

100 to 1500

20.0 to 400.0

0.0 to 750.0

200 to 400

300 to 700

199.9 to 400.0

199.9 to 700.0

0 to 1,700

0 to 3,000

0 to 1,700

0 to 3,000

Default setting: 0
Applicable standards (K, J, T, R, S): JIS C1602-1995 and IEC 60584-1

Models with Resistance Thermometer Inputs


Model
(temperature input)

Set value

Input type

Pt input

Pt100

Range
C

-200 to 850

-300 to 1500

-199.9 to 500.0

-199.9 to 900.0

Default setting: 8
Applicable standards (Pt100): JIS C1604-1997 and IEC 60751

Alarm Types
Select alarm types out of the 11 alarm types listed in the following
table.
Setting

Positive alarm
value (X)

No alarm

Deviation upper/
lower limit

ON
OFF

Deviation upper
limit

ON
OFF

Deviation lower
limit

ON
OFF

Deviation upper/
lower range

ON
OFF

5
(See
note.)

Deviation upper/
lower limit standby
sequence ON

ON
OFF

6
(See
note.)

Deviation upper
limit standby
sequence ON

ON
OFF

7
(See
note.)

Deviation lower
limit standby
sequence ON

ON
OFF

Absolute value
upper limit

ON
OFF

Absolute value
lower limit

ON
OFF

10
(See
note.)

Absolute value
upper limit standby
sequence ON

ON
OFF

11
(See
note.)

Absolute value
lower limit standby
sequence ON

ON
OFF

12

Do not set.

Alarm type

Negative alarm
value (X)

Note: Alarms with a Standby Sequence


The alarm is blocked until the first safe-state is reached.
Unwanted alarm during start-up are prevented.
Example: Deviation Lower Limit Standby Sequence ON
Alarm hysteresis
(always 0.2 C/F)

Alarm value

Output OFF
X

Process value

Time

Always ON
SP

Standby sequence cleared

X
SP
X

ON
OFF

SP
X

ON
OFF

Alarm with standby sequence


Alarm without standby sequence

SP

The standby sequence is cleared when the alarm OFF condition has
been met.
The standby sequence is started again when any of the following
conditions is met.
Operation is started (power is turned ON or operation is switched
from stop to run).
The alarm value is changed.
The temperature input offset is changed.
The set point is changed.

X
SP

Always OFF
SP
X

Always OFF

SP

X
SP

X
SP
X
0
X
0
X
0

X
0

ON
OFF

ON
OFF

ON
OFF
ON
OFF

ON
OFF

ON
OFF

X
SP

X
SP
X
0
X
0
X
0

X
0

E5CSL/E5CWL
Characteristics
Thermocouple: (See note 1.)
(0.5% of indicated value or 1C, whichever is greater) 1 digit max.
Platinum resistance thermometer:
(0.5% of indicated value or 1C, whichever is greater) 1 digit max.

Indication accuracy
Influence of temperature

R and S thermocouple inputs:


(1% of PV or 10C, whichever is greater) 1 digit max.
K, J, and T thermocouple inputs:
(1% of PV or 4C, whichever is greater) 1 digit max.
Platinum resistance thermometer inputs:
(1% of PV or 2C, whichever is greater) 1 digit max.

Influence of voltage
Hysteresis

0.1 to 999.9 (in units of 0.1) C/F

Proportional band (P)

0.1 to 999.9 (in units of 0.1) C/F

Integral time (I)

0 to 3999 s (in units of 1 s)

Derivative time (D)

0 to 3999 s (in units of 1 s)

Control period

0.5, 1 to 99 s (in units of 1 s)

Alarm setting range

1999 to 9999 (decimal point position depends on input type)

Sampling period

250 ms

Affect of signal source resistance

Thermocouple: 0.1C/ max. (100 max.) (See note 2.)


Platinum resistance thermometer: 0.6C/ max. (10 max.)

Insulation resistance

20 M min. (at 500 VDC)

Dielectric strength

2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration resistance
Shock
resistance

Malfunction

10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

Destruction

10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions

Malfunction

100 m/s2 min., 3 times each in X, Y, and Z directions

Destruction

300 m/s2 min., 3 times each in X, Y, and Z directions

Weight

Controller: Approx. 100 g, Mounting Bracket: Approx. 10 g

Degree of protection

Front panel: IP50


Rear case: IP20, Terminals: IP00

Memory protection

Non-volatile memory (number of writes: 100,000 times)

Conformed standards

EN61326, EN61010-1, IEC61010-1


VDE0106 Part 100 (Finger protection), when the terminal cover is mounted.

EMC

Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interrupting:

EN55011 Group1 Class A


EN55011 Group1 Class A
EN61000-4-2
EN61000-4-3 10 V/m
EN61000-4-6 3 V
EN61000-4-4
EN61000-4-5
EN61000-4-11

Note: 1. The indication accuracy of K and T thermocouples at a temperature of 100C max. is 2C 1 digit maximum. The indication accuracy
of the R and S thermocouples at a temperature of 200C max. is 3C 1 digit max.
2. R, and S sensors: 0.2C/ max. (100 max.)

Electrical Life Expectancy Curve for Relays (Reference Values)


100

No. of operations (x 104)

250 VAC, 30 VDC resistive load


50
30

10

5
3

1
0

Contact current (A)

E5CSL/E5CWL

External Connections
A voltage output (control output 1) is not electrically insulated from the internal circuits. When using a grounding thermocouple, do not connect
any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the measured
temperature values as a result of leakage current.

E5CWL

E5CSL

Control Output
Relay output: 250 VAC, 3 A (resistive load)
Voltage output (for driving SSR): 12 VDC, 21 mA

Control Output
Relay output: 250 VAC, 3 A (resistive load)
Voltage output (for driving SSR): 12 VDC, 21 mA

2
DO NOT
USE

10

Pt input

Control output

Control output

Input power supply:


100 to 240 VAC,
50/60 Hz

10

Pt input

TC input

DO NOT
USE

Alarm Output
Relay output: 250 VAC, 1 A
(resistive load)
Input power supply:
100 to 240 VAC,
50/60 Hz

TC input

Nomenclature
E5CSL
E5CWL
(1)

(1)
(5)

(3)
(7)

(2)

(6)
(4)

(6)

(9)

(10) (9)

(11)

(8)
(12)

(7)

(8)
(12)

E5CWL

(14)

Displays the process value (PV) or parameter. For the E5CSL,


the set point or parameter setting is also displayed.
Displays the set point (SP) or parameter setting.
Show the relation between the process value and the set point.
Lit: The process value is more than 5C/F higher than the set point.
Lit: The process value is more than 5C/F lower than the set point.
Lit: The process value is within 5C/F of the set point.
The relevant deviation indicator will flash during autotuning.

(2) Display No. 2


(3) Deviation
Indicators

(11)

(13)

E5CSL
(1) Display No. 1

(10)

(4) SP
(5) ALM
(6) OUT

Lit while the set point is displayed on display No. 1 (E5CSL only).
Lit while the alarm is ON. Not lit while the alarm is OFF.
Lit while the control output is ON. Not lit while the control output is

OFF.
(7) STOP

Not lit during operation. Lit while operation is stopped.

(8) O

Level Key: Changes the setting level.

(9) M

Mode Key: Changes the parameter within the setting level.

(13)
(14)

(10) D
(11) U

Down Key: Reduces the setting.


Up Key: Increases the setting.

(12) O+M

Press these keys for at least 3 seconds in Operation Level or Adjustment Level to go to Protect Level.

(13) M+D

Press these keys for at least 1 second in Protect Level to return to Operation Level.
Press these keys for at least 2 seconds to start or stop autotuning.*1

(14) M+U

Press these keys for at least 2 seconds to start or stop operation.*2

*1: These keys are disabled when starting and stopping autotuning has been disabled with operation control
key protection.
*2: These keys are disabled when starting and stopping operation has been disabled with operation control
key protection.

Dimensions
4848
4

64
60

44.844.8

Panel Cutout
Individual Mounting
Group Mounting
+1.0
0

58

45 +0.6
0

60 min.

Package Contents
Temperature Controller
Adapter
Instruction Manual

Adapter

*The dimensions are the same


for the E5CSL.

Solderless terminal size: M3.5


Terminal Cover: E53-COV19 (sold separately)
Front Panel: E53-COV20 (sold separately)

45 +0.6
0

45 +0.6
0

Recommended panel thickness is


1 to 5 mm.
Group mounting is not possible in
the vertical direction. (Maintain the
specified mounting space between
Controllers.)
When two or more Controllers are
mounted, make sure that the
surrounding temperature does not
exceed the ambient operating
temperature given in the
specifications.

E5CSL/E5CWL
Accessories (Order Separately)
Terminal Cover

Front Panel

E53-COV19

E53-COV20
4

43.3

48 48

4.8

43.8

1.2

Note: The E53-COV10 cannot be used.

Note: 1. This Front Panel accessory is required to


attach the Y92A-48B or Y92A-48D.
2. This Front Panel accessory is only the frame.
It does not include the plastic cover.

Adapter
Note: 1. Use this Adapter when the panel has already been prepared for the E5B@.
2. Only black is available.

Y92F-45

Fixture (Accessory)
76

4.7

69.6 to 77.6
72 72

67 67 87

Panel (1to8mm)

72 x 72

2.7

87

48 x 48

Mounted to E5CWL

62.8
78

E5CSL/E5CWL
Safety Precautions
!CAUTION
Do not touch the terminals while power is being
supplied.
Doing so may occasionally result in minor injury due to
electric shock.
Do not allow pieces of metal, wire clippings, or fine
metallic shavings or filings from installation to enter the
product. Doing so may occasionally result in electric
shock, fire, or malfunction.
Do not use the product where subject to flammable or
explosive gas. Otherwise, minor injury from explosion
may occasionally occur.
Never disassemble, modify, or repair the product or
touch any of the internal parts. Minor electric shock, fire,
or malfunction may occasionally occur.
If the output relays are used past their life expectancy,
contact fusing or burning may occasionally occur.
Always consider the application conditions and use the
output relays within their rated load and electrical life
expectancy.
The life expectancy of output relays varies considerably
with the output load and switching conditions.
Tighten the terminal screws to between 0.74 and 0.90
Nm. Loose screws may occasionally result in fire.
Set the parameters of the product so that they are
suitable for the system being controlled. If they are not
suitable, unexpected operation may occasionally result
in property damage or accidents.
A malfunction in the Temperature Controller may
occasionally make control operations impossible or
prevent alarm outputs, resulting in property damage. To
maintain safety in the event of malfunction of the
Temperature Controller, take appropriate safety
measures, such as installing a monitoring device on a
separate line.

Precautions for Safe Use


Be sure to observe the following precautions to prevent operation
failure, malfunction, or adverse affects on the performance and
functions of the product. Not doing so may occasionally result in
unexpected events.
1. The product is designed for indoor use only. Do not use the
product outdoors or in any of the following locations.
Places directly subject to heat radiated from heating equipment.
Places subject to splashing liquid or oil atmosphere.
Places subject to direct sunlight.
Places subject to dust or corrosive gas (in particular, sulfide gas
and ammonia gas).
Places subject to intense temperature change.
Places subject to icing and condensation.
Places subject to vibration and large shocks.
2. Use/store within the rated temperature and humidity ranges.
Provide forced-cooling if required.
3. To allow heat to escape, do not block the area around the product.
Do not block the ventilation holes on the product.
4. Be sure to wire properly with correct polarity of terminals.
5. Use specified size (M3.5, width 7.2 mm or less) crimped terminals
for wiring. To connect bare wires to the terminal block, use copper
braided or solid wires with a rated temperature of over 70C and a
gauge of AWG24 to AWG14 (equal to a cross-sectional area of
0.205 to 2.081 mm2). (The stripping length is 5 to 6 mm.) Up to two
wires of same size and type, or two crimped terminals can be
inserted into a single terminal.
6. Do not wire the terminals which are not used.
7. Allow as much space as possible between the controller and
devices that generate a powerful high-frequency or surge.
Separate the high-voltage or large-current power lines from other
lines, and avoid parallel or common wiring with the power lines
when you are wiring to the terminals.
8. Use this product within the rated load and power supply.

9. Make sure that the rated voltage is attained within two seconds of
turning ON the power using a switch or relay contact. If the voltage
is applied gradually, the power may not be reset or output
malfunctions may occur.
10.Make sure that the Controller has 30 minutes or more to warm up
after turning ON the power before starting actual control
operations to ensure the correct temperature display.
11.A switch or circuit breaker should be provided close to this unit.
The switch or circuit breaker should be within easy reach of the
operator, and must be marked as a disconnecting means for this
unit.
12.Do not use paint thinner or similar chemical to clean with. Use
standard grade alcohol.
13.Design system (control panel, etc) considering the 2 second of
delay that the controllers output to be set after power ON.
14.The output may turn OFF when shifting to certain levels. Take this
into consideration when performing control.
15.The number of non-volatile memory write operations is limited.

E5CSL/E5CWL
Precautions for Correct Use

Mounting

Service Life

Mounting to a Panel

1. Use the product within the following temperature and humidity


ranges:
Temperature: 10 to 55C (with no icing or condensation)
Humidity: 25% to 85%
If the product is installed inside a control board, the ambient
temperature must be kept to under 55C, including the
temperature around the product.
2. The service life of electronic devices like Temperature Controllers
is determined not only by the number of times the relay is switched
but also by the service life of internal electronic components.
Component service life is affected by the ambient temperature: the
higher the temperature, the shorter the service life and, the lower
the temperature, the longer the service life. Therefore, the service
life can be extended by lowering the temperature of the
Temperature Controller.
3. When two or more Temperature Controllers are mounted
horizontally close to each other or vertically next to one another,
the internal temperature will increase due to heat radiated by the
Temperature Controllers and the service life will decrease. In such
a case, use forced cooling by fans or other means of air ventilation
to cool down the Temperature Controllers. When providing forced
cooling, however, be careful not to cool down the terminals
sections alone to avoid measurement errors.

1. Insert the E5CSL/E5CWL into the mounting hole in the panel.


2. Push the adapter from the terminals up to the panel, and
temporarily fasten the E5CSL/E5CWL.

Measurement Accuracy

Mounting the Terminal Cover

1. When extending or connecting the thermocouple lead wire, be sure


to use compensating wires that match the thermocouple types.
2. When extending or connecting the lead wire of the platinum
resistance thermometer, be sure to use wires that have low
resistance and keep the resistance of the three lead wires the
same.
3. Mount the product so that it is horizontally level.
4. If the measurement accuracy is low, check to see if input shift has
been set correctly.

Make sure that the rib on the E53-COV19 Terminal Cover to lower
side, and then attach the this cover to E5CSL/E5CWL.

Waterproofing
The degree of protection is as shown below. Sections without any
specification on their degree of protection or those with IP@0 are not
waterproof.
Front panel: IP50
Rear case: IP20, Terminal section: IP00

Operating Precautions
1. It takes approximately two seconds for the outputs to turn ON from
after the power supply is turned ON. Due consideration must be
given to this time when incorporating Temperature Controllers in a
sequence circuit.
2. When starting operation after the Temperature Controller has
warmed up, turn OFF the power and then turn it ON again at the
same time as turning ON power for the load. (Instead of turning the
Temperature Controller OFF and ON again, switching from STOP
mode to RUN mode can also be used.)
3. Avoid using the Controller in places near a radio, television set, or
wireless installing. These devices can cause radio disturbances
which adversely affect the performance of the Controller.

Terminal Cover
E53-COV19
(Order separately)

Set the rib to lower side.

Adapter
Panel

Precautions when Wiring


Separate input leads and power lines in order to prevent external
noise.
Use specified size (M3.5, width 7.2 mm or less) crimped terminals
for wiring. To connect bare wires to the terminal block, use copper
braided or solid wires with a rated temperature of over 70C and a
gauge of AWG24 to AWG14 (equal to a cross-sectional area of
0.205 to 2.081 mm2 ). (The stripping length is 5 to 6 mm.) Up to two
wires of same size and type, or two crimped terminals can be
inserted into a single terminal.
Use crimp terminals when wiring the terminals.
Use the suitable wiring material and crimp tools for crimp terminals.
Tighten the terminal screws to between 0.74 and 0.90 NEm.
Use the following types of crimp terminals for M3.5 screws.

7.2 mm max.

7.2 mm max.

E5CSL/E5CWL

E5CSL/E5CWL

10

E5CSL/E5CWL

Warranty and Application Considerations


Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranty and Limitations of Liability


WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.

Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.

Disclaimers
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

11

OMRON Corporation

Industrial Automation Company

Authorized Distributor:

Tokyo, JAPAN

Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC


One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.


No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.


Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON Corporation 2010 All Rights Reserved.


In the interest of product improvement,
specifications are subject to change without notice.
Printed in Japan
Cat. No. H167-E1-01
0810