Omega Air D.O.O. Ljubljana Product Catalogue 2009
Omega Air D.O.O. Ljubljana Product Catalogue 2009
Omega Air D.O.O. Ljubljana Product Catalogue 2009
...research...
...innovations...
...grand designs...
...great plans...
...giant ideas...
That’s what we are...
Faithfully trying to serve you...
Erik Krušec Špela Remic Tilen Lovrečič Katja Koritnik Luka Tršar
Sales manager - World market Sales&technical support Sales&technical support Sales&technical support Sales&technical support
T: +386 1 200 68 60 T: +386 1 200 68 61 T: +386 1 200 68 62 T: +386 1 200 68 64 T: +386 1 200 68 13
M: +386 30 362 140 F: +386 1 200 68 53 M: +386 30 362 180 F: +386 1 200 68 53 F: +386 1 200 68 53
F: +386 1 200 68 53 e: spela.remic@omega-air.si F: +386 1 200 68 53 e: katja.koritnik@omega-air.si e: luka.trsar@omega-air.si
e: erik.krusec@omega-air.si e: tilen.lovrecic@omega-air.si
2
Our goal:
Top quality
Dear customers!
This year Omega Air is celebrating 20 years of existence.
During all these years we have been developing and
growing and today we have reach over 100 employees.
Certificates
Quality Managenent Certificate ISO 9001:2000 i Certificate of Quality System Approval (module H1)
www.omega-air.si 3
Product selection chart
FILTERS FOR INDUSTRIAL APPLICATIONS
400 bar
CHP
CHP series
100, 250, 400 bar
NEW!
carbon steel
high pressure filters
Filter selection
>> page 28-29
programme
250 bar
now available!
Send a request to our sales department!
AHP series
64 bar
100 bar
aluminium
high pressure filters
>> page 26-27
64 bar
AHP
50 bar
HF
HF series
20 bar CF
50 bar 16 bar
AF BF
cast aluminium
500 Nm3/h
1000 Nm3/h
2000 Nm3/h
5000 Nm3/h
10000 Nm3/h
20000 Nm3/h
30000 Nm3/h
high pressure filters
>> page 24-25
1000 Nm3/h
2000 Nm3/h
5000 Nm3/h
10000 Nm3/h
20000 Nm3/h
SF series
SPF series PF series
16 bar
16 bar 16 bar
stainless steel
stainless steel sterile filters stainless steel
sterile filters process filters
>> page 34-35
>> page 36-37 >> page 30-31
4
Product selection chart
CONDENSATE SEPARATORS
500 Nm3/h
1000 Nm3/h
2000 Nm3/h
5000 Nm3/h
10000 Nm3/h
20000 Nm3/h
aluminium
condensate separators
3
>> page 8-9 /8’’ to 2 1/2’’
CS series 16 bar
16 bar
0 bar
500 Nm3/h
1000 Nm3/h
2000 Nm3/h
5000 Nm3/h
10000 Nm3/h
20000 Nm3/h
carbon steeel
condensate separators
>> page 22 DN80 to DN125
CS SS series 16 bar
16 bar
0 bar
500 Nm3/h
1000 Nm3/h
2000 Nm3/h
5000 Nm3/h
10000 Nm3/h
20000 Nm3/h
stainless steel
condensate separators
>> page 23 DN80 to DN100
100 l/h
150 l/h
200 l/h
250 l/h
300 l/h
timer controlled
condensate drain
MCD
>> page 16
TD 16S 16 bar
16 bar AOK 16S
0 bar
50 l/h
100 l/h
150 l/h
200 l/h
250 l/h
300 l/h
timer controlled
condensate drain
>> page 17 AOK 16B
ECD 15-40-90-150 16 bar
16 bar
0 bar
50 l/h
100 l/h
150 l/h
200 l/h
250 l/h
300 l/h
WATER-OIL SEPARATORS
16 bar
0 bar
WOS 4-8-20-35
500 Nm3/h
1000 Nm3/h
1500 Nm3/h
2000 Nm3/h
www.omega-air.si 5
AF series - 16 bar
Compressed air filters
The type and size of filters depends of compressed air flow, type and quantity
of polution.
OPTIONAL EQUIPMENT
B
Filter Pipe size Flow rate Dimensions [mm] Mass Flow rate Dimensions [inch] Mass
housing
inch Nm3/h A B C D kg SCFM A B C D lb
80
model
AF 0056 3/8’’ 60 187 88 20 60 0,7 35 7 3/8 3 1 /2 13
/16 2 3 /8 1,54
C
AF 0476 1 1/2’’ 510 461 125 32 140 2,5 300 17 3/4 4 15/16 1 5/16 5 1 /2 5,51
AF 0706 1 1/2’’ 780 640 125 32 160 3,2 459 25 5/16 4 15/16 1 5/16 6 1 /4 7,05
AF 0946 2’’ 1000 684 163 43 520 5,1 588 27 3/8 6 3 /8 1 7 /8 20 1/2 11,25
AF 1506 2’’ 1500 935 163 43 770 7,1 882 36 3/4 6 3 /8 1 7 /8 30 5/16 15,65
3 3 7
AF 1756 2 1/2’’ 1680 935 163 43 770 6,9 990 36 /4 6 /8 1 /8 30 5/16 15,21
R 1/2’’ AF 2006 3 2160 795 240 59 630 12,9 1270 31 1/4 9 1 /2 2 3 /8 24 3/4 28,44
D
AF 2406 3 2760 1000 240 59 780 14,0 1620 39 1/3 9 1 /2 2 3 /8 30 11/16 30,86
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,52 0,63 0,75 0,88 1,00 1,13 1,26 1,38 1,52 1,65 1,76 1,87 2,00 2,14
6
AF filter cartridges
Filter cartridges
Omega Air filter cartridge production includes 6 filtration
stages (B, P, R, M, S and A), which are designed to remove
particulates, water, oil vapours, taste and odours from
compressed air.
06050 60 35 16/232 65/149 AF 0056 06050 B15 06050 P 06050 R 06050 M 06050 S 06050 A
07050 78 46 16/232 65/149 AF 0076 07050 B15 07050 P 07050 R 07050 M 07050 S 07050 A
14050 120 70 16/232 65/149 AF 0106 14050 B15 14050 P 14050 R 14050 M 14050 S 14050 A
12075 198 116 16/232 65/149 AF 0186 12075 B15 12075 P 12075 R 12075 M 12075 S 12075 A
22075 335 197 16/232 65/149 AF 0306 22075 B15 22075 P 22075 R 22075 M 22075 S 22075 A
32075 510 300 16/232 65/149 AF 0476 32075 B15 32075 P 32075 R 32075 M 32075 S 32075 A
50075 780 459 16/232 65/149 AF 0706 50075 B15 50075 P 50075 R 50075 M 50075 S 50075 A
51090 1000 588 16/232 65/149 AF 0946 51090 B15 51090 P 51090 R 51090 M 51090 S 51090 A
76090 1500 882 16/232 65/149 AF 1506 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A
76090 1680 990 16/232 65/149 AF 1756 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A
51140 2160 1270 16/232 65/149 AF 2006 51140 B15 51140 P 51140 R 51140 M 51140 S 51140 A
75140 2760 1620 16/232 65/149 AF 2406 75140 B15 75140 P 75140 R 75140 M 75140 S 75140 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 7
CKL-B series
Condensate separators
MCD
AOK 16B
TD16 TD16S
AOK 20B ECD
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
8
Condensate separators
Benefits
Construction of aluminium cyclone separators assures high efficiency condensate separation with low pressure drop.
Cartridge inside Cyclone separator assures reliable operation for the life of the separator, with no possibility of clogging and
increased operating costs.
Condensate Cyclone separator CKL-B satisfies all needs of applications in a wide temperature range from 1,5 to 65 °C (35 to
149 °F) and in a pressure range up to 16 bar (232 psi).
All alluminium separator bodies are coated with powder paint to eliminate corrosion.
Threaded connections are BSP according to ISO7/1 or NPT to ANSI B2.1, if supplied in North America.
air
condensate
(oil, water)
B
Connection
Flow rate Dimensions [mm] Dimensions [inch] Mass
Model size
C
CKL 200 B 3 2850 1677 795 240 59 630 31 5/16 9 1/2 2 5/16 24 3/4 13,4 29,5
www.omega-air.si 9
CF series - 20 bar
Compressed air filters CF Series are used for efficient removal of solid
particles, water, oil vapours, taste and odours from compressed air in
industrial applications.
The type and size of filters depends of compressed air flow, type and
quantity of polution.
B
Pipe size Flow rate Dimensions [mm] Flow rate Dimensions [inch]
Filter
housing
80
CF 41 1’’ 360 352 125 32 140 212 13 7/8 4 7/8 1 1/4 5 1/2
CF 42 1 1/4’’ 432 352 125 32 140 254 13 7/8 4 7/8 1 1/4 5 1/2
CF 43 1 1/2’’ 510 450 125 32 160 300 17 7/8 4 7/8 1 1/4 4 5/16
CF 44 1 1/2’’ 750 450 125 32 160 441 17 7/8 4 7/8 1 1/4 4 5/16
CF 50 2’’ 888 605 160 43 180 522 23 3/4 4 5/16 1 5/8 7 1/8
CF 51 2’’ 1176 605 160 43 180 692 23 3/4 4 5/16 1 5/8 7 1/8
CF 52 2 1/2’’ 1440 685 160 43 200 847 27 4 5/16 1 5/8 7 7/8 R 1/2’’
D
1 7 3
CF 60 3’’ 1968 1070 240 60 300 1158 42 /8 9 /16 2 /8 11 3/4
CF 61 3’’ 2760 1070 240 60 300 1624 42 1/8 9 7/16 2 3/8 11 3/4
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Correction factor 0,38 0,52 0,63 0,75 0,88 1,00 1,13 1,26 1,38 1,52 1,65 1,76 1,87 2,00 2,14
10
CF filter cartridges
The design of CF Filter media ensures the effective and efficient removal
most of contaminates from compressed air systems. Note that these
filters will not remove carbon monoxide or carbon dioxide.
All materials are suitable for operation in the temperature range from
1,5 to 65 °C (35 to 149°F). They are corrosion-proof and suitable for most
of applications.
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 20 bar (290 psi).
CF 20 72 42 20/290 65/149 20 CB 20 CP 20 CR 20 CM 20 CS 20 CA
CF 21 96 56 20/290 65/149 21 CB 21 CP 21 CR 21 CM 21 CS 21 CA
CF 30 150 88 20/290 65/149 30 CB 30 CP 30 CR 30 CM 30 CS 30 CA
CF 31 216 127 20/290 65/149 31 CB 31 CP 31 CR 31 CM 31 CS 31 CA
CF 40 282 166 20/290 65/149 40 CB 40 CP 40 CR 40 CM 40 CS 40 CA
CF 41 360 212 20/290 65/149 41 CB 41 CP 41 CR 41 CM 41 CS 41 CA
CF 42 432 254 20/290 65/149 42 CB 42 CP 42 CR 42 CM 42 CS 42 CA
CF 43 510 300 20/290 65/149 43 CB 43 CP 43 CR 43 CM 43 CS 43 CA
CF 44 750 441 20/290 65/149 44 CB 44 CP 44 CR 44 CM 44 CS 44 CA
CF 50 888 522 20/290 65/149 50 CB 50 CP 50 CR 50 CM 50 CS 50 CA
CF 51 1176 692 20/290 65/149 51 CB 51 CP 51 CR 51 CM 51 CS 51 CA
CF 52 1440 847 20/290 65/149 52 CB 52 CP 52 CR 52 CM 52 CS 52 CA
CF 60 1968 1158 20/290 65/149 60 CB 60 CP 60 CR 60 CM 60 CS 60 CA
CF 61 2760 1624 20/290 65/149 61 CB 61 CP 61 CR 61 CM 61 CS 61 CA
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 <90 / 1,3 120 / 1,74
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 11
Compressed air equipment
Technical data
Technical data
Technical data
12
AK - Filter assembly kit
Universal usage
Construction of assenbly kit is universal and
it can be used for any filter types, including
filters of other world producers.
www.omega-air.si 13
ECD series
Benefits
- aluminium housing
- integrated filter mesh
- compact design
- two-way connections
- eloxated housing
- contactless measuring
- NEW: direct acting, self cleaning valve (patented)
- NEW: blocked plunger release procedure
- NEW: operating diagnostic monitoring
- warning LED light for ’’drain operating’’ and ’’alarm’’
- AC versions (for DC version please contact Omega Air)
- IP 54 electrical protection
14
Electronic condensate drain
115 VAC 115 V ± 10% 115 V ± 10% 115 V ± 10% 115 V ± 10%
Voltage
230 VAC 230 V ± 10% 230 V ± 10% 230 V ± 10% 230 V ± 10%
115 VAC 24 VA 24 VA 24 VA 24 VA
Power
230 VAC 24 VA 24 VA 24 VA 24 VA
Frequency 50-60 Hz
Operating pressure 0-16 bar (0 - 232 psi)
Drain capacity (at 7 bar/101 psi) 15 l/h (0,0088 cfm) 40 l/h (0,023 cfm) 90 l/h (0,053 cfm) 150 l/h (0,088 cfm)
Operating temperature range 1,5 - 65°C (35-149°F)
Inlet connection R 1/2’’ R 1/2’’ R 1/2’’ R 1/2’’
Outlet connection R 1/8’’ R 1/8’’ R 1/8’’ R 1/8’’
Power interface 3 × 0,75 mm2 3 × 0,75 mm2 3 × 0,75 mm2 3 × 0,75 mm2
Protection class IP54 IP54 IP54 IP54
Mass [kg] 0,9 0,9 1,05 1,15
Dimensions A × B × C [mm] 120 × 82 × 125 120 × 82 × 125 120 × 82 × 135 120 × 82 × 150
* Higher motor power capacities available on request. Please contact Omega Air.
Please take the relevant climate zone into account when dimensioning yours specific ECD drain series application:
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
www.omega-air.si 15
TD 16
Benefits
- easy opening time settings
- easy opening frequency settings
- no moving parts
- reliable operating without clogging and unsensible to
outside conditions
- test button
- warning LED light for condense disposal phase
- DC and AC versions
Technical Data
- min/max operating temperature: 1,5 to 65 °C (35 to 149 °F)
- min/max operating pressure: 0-16 bar / 0-232 psi
- input connection: R 1/2”
- output connection: R 1/8”
- output pipe diameter: 6-8 mm
- capacity at 10 bar (145 psi): 0,2 - 300 l/h / 0,00012 - 0,17 cfm
- mass: 0,35 kg / 0,77 lb
16
TD16 S
Benefits
- easy opening time settings
- easy opening frequency settings
- no moving parts
- reliable operating without clogging and unsensible to
outside conditions
Technical data - test button
- warning LED light for condense disposal phase
- min/max operating temperature: 1,5 to 65 °C (35 to 149 °F) - DC and AC versions
- min/max operating pressure: 0-16 bar / 0-232 psi
- Input connection: R 1/2”
- output connection: R 1/8”
- output pipe diameter: 6-8 mm
- capacity at 10 bar (145 psi): 0,2 - 114 l/h
- mass: 0,35 kg
C
Protection Cable Dimensions
Model Voltage Frequency El. power
class dimension A B C
TD16 24 VAC 24 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2 88 mm 90 mm 123 mm
TD16 115 VAC 115 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2 3 7/16 inch 3 1/2 inch 4 7/8 inch
TD16 230 VAC 230 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2
B
www.omega-air.si 17
AOK 20B
Technical data
- material: aluminium alloy
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0 - 20 bar (0 - 290 psi)
- connection: R 1/2’’
- oil resistant o-ring
1/2’’
107
130
132
1/2’’
18
MCD, AOK 16S, AOK 16B
Technical data
- material: brass
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0-16 bar (0-232 psi)
- connection: R 1/2’’
- oil resistant o-ring
Technical data
- material: durable plastic, brass
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0-16 bar (0-232 psi)
- connection: R 3/8’’
- oil resistant o-ring
Technical data
- material: durable plastic, brass
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- operating pressure range: 0-16 bar (0-232 psi)
- connection: R 1/2’’
- oil resistant o-ring
www.omega-air.si 19
BF series - 16 bar
Compressed air filters
B
øD
E
SIZES: SIZES:
BF 0240 BF 1200
BF 0300 BF 1500
A
øD
BF 0450 BF 1800
A
BF 0600 BF 2500
C min
BF 0900 BF 3000
min.200 mm
min.650 mm
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
20
BF filter cartridges
Filter cartridges
Omega Air filter cartridge production includes 6 filtration stages (B, P,
R, M, S and A), which are designed to remove particulates, water, oil
vapours, taste and odours from compressed air.
The design of filter media ensures the effective and efficient removal
most of contaminates in compressed air systems. Note that these filters
will not remove carbon monoxide or carbon dioxide.
All materials are suitable for operation in the temperature range from
1,5 to 65 °C (35 to 149°F). They are corrosion-proof and suitable for most
of applications.
The filter and cartridge size is determined by the compressed air flow.
They are all designed for operation pressure up to 16 bar (232 psi).
76090 1500 882 16/232 65/149 All 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 21
CS series
G
H
B
C
F
min 200 mm
Pipe
Flow rate Dimensions [mm] Dimensions [inch] Mass
Model size
DN Nm3/min SCFM A B C D E F G H A B C D E F G H kg lb
CS 14 DN80 14 495 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1 /2 3 1 /2 1
/2 6 1 /4 11 7/8 1 3 /8 23 50,7
CS 21 DN80 21 740 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1 /2 3 1 /2 1
/2 6 1 /4 11 7/8 1 3 /8 23 50,7
CS 28 DN80 28,5 1000 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1 /2 3 1 /2 1
/2 6 1 /4 11 7/8 1 3 /8 23 50,7
CS 62 DN125 62,0 2190 1041 280 133,0 133,0 1/2’’ 219,1 390 43 41 11 5 1 /4 5 1 /4 1
/2 8 5 /8 15 3/8 1 11/16 53 116,8
22
CS SS series
G
E
G
A
F
H
B
C
A B C D E F G H
CS SS 14 DN80 14 745 182 88,9 88,9 1/2’’ 159,0 302 35 23
www.omega-air.si 23
HF series - 50 bar
Connection
B Filter Flow rate Dimensions [mm] Dimensions [inch] Mass Filter
[D]
model cartridge
3
inch Nm /h SCFM A B C A B C kg lb
C
HF 007 1/2 450 265 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 6060
D
HF 010 3/4 715 420 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 7060
HF 018 1 1300 765 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 12060
HF 047 1 1/2 1800 1059 535 160 45 21 1/16 6 5/16 1 3 /4 9,5 20,9 HF 22090
1 5
HF 070 1 1/2 2550 1500 535 160 45 21 /16 6 /16 1 3 /4 9,5 20,9 HF 32090
A
HF 094 2 3150 1853 715 160 45 21 1/8 6 5/16 1 3 /4 12,2 26,9 HF 50090
HF 150 2 5100 3000 715 160 45 21 1/8 6 5/16 1 3 /4 12,2 26,9 HF 51090
CORRECTION FACTORS
Operating pressure [bar] 4 6 8 10 15 20 30 40 50
Operating pressure [psi] 58 87 116 145 217 290 435 580 725
1/2’’ Correction factor 0,14 0,22 0,28 0,34 0,47 0,56 0,70 0,85 1,00
24
HF filter cartridges
HF 007 450 265 50/725 65/149 HF 6060 B HF 6060 P HF 6060 R HF 6060 M HF 6060 S HF 6060 A
HF 010 715 420 50/725 65/149 HF 7060 B HF 7060 P HF 7060 R HF 7060 M HF 7060 S HF 7060 A
HF 018 1300 765 50/725 65/149 HF 12060 B HF 12060 P HF 12060 R HF 12060 M HF 12060 S HF 12060 A
HF 047 1800 1059 50/725 65/149 HF 22090 B HF 22090 P HF 22090 R HF 22090 M HF 22090 S HF 22090 A
HF 070 2550 1500 50/725 65/149 HF 32090 B HF 32090 P HF 32090 R HF 32090 M HF 32090 S HF 32090 A
HF 094 3150 1854 50/725 65/149 HF 50090 B HF 50090 P HF 50090 R HF 50090 M HF 50090 S HF 50090 A
HF 150 5100 3000 50/725 65/149 HF 51090 B HF 51090 P HF 51090 R HF 51090 M HF 51090 S HF 51090 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 25
AHP series - 64 bar
Filter Connections
Flow rate Dimensions [mm] Mass
housing [D] Cartridge
model inch Nm3/h A B C kg
AHP 005 3/8’’ 30 167 104 90 2,25 HP 06050
B
AHP 007 1/2’’ 60 167 104 90 2,25 HP 07050
AHP 010 3/4’’ 120 232 104 90 2,84 HP 14050
AHP 018 1’’ 180 258 150 120 6,45 HP 12075
D
CORRECTION FACTORS
Operating pressure [bar] 4 6 8 10 15 20 30 40 50 60 64
Operating pressure [psi] 58 87 116 145 217 290 435 580 725 870 928
Correction factor 0,14 0,22 0,28 0,34 0,47 0,56 0,70 0,85 0,88 0,91 1,00
C
1/2’’
26
AHP filter cartridges
AHP 005 30 17,6 64/928 65/149 AHP 06050 B AHP 06050 P AHP 06050 R AHP 06050 M AHP 06050 S AHP 06050 A
AHP 007 60 35,3 64/928 65/149 AHP 07050 B AHP 07050 P AHP 07050 R AHP 07050 M AHP 07050 S AHP 07050 A
AHP 010 120 70,6 64/928 65/149 AHP 14050 B AHP 14050 P AHP 14050 R AHP 14050 M AHP 14050 S AHP 14050 A
AHP 018 180 106 64/928 65/149 AHP 12075 B AHP 12075 P AHP 12075 R AHP 12075 M AHP 12075 S AHP 12075 A
AHP 030 270 159 64/928 65/149 AHP 22075 B AHP 22075 P AHP 22075 R AHP 22075 M AHP 22075 S AHP 22075 A
AHP 047 360 212 64/928 65/149 AHP 32075 B AHP 32075 P AHP 32075 R AHP 32075 M AHP 32075 S AHP 32075 A
AHP 094 720 423 64/928 65/149 AHP 51090 B AHP 51090 P AHP 51090 R AHP 51090 M AHP 51090 S AHP 51090 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 27
CHP series - 100-250-400 bar
Carbon steel high pressure filters CHP are used for industrial
high pressure applications up to 400 bar (5800 psi).
Connections
Model Flow rate Dimensions [mm] Mass
[D] Cartridge size
filtra
inch Nm3/h A B C kg
B CHP 003 1/4’’ 40 165 83,5 70 4,6 0305
CHP 005 3/8’’ 70 165 83,5 70 4,6 0310
CHP 007 1/2’’ 130 210 105 85 8,7 0420
CHP 010 3/4’’ 195 210 105 85 9,3 0520
D
CORRECTION FACTORS
Operating pressure [bar] 25 40 64 100 250 400
C Operating pressure [psi] 362 580 928 1450 3625 5800
1/2’’ Correction factor 3 5 8 12 12 12
28
CHP filter cartridges
CHP 003 40 23,5 100/250/400 65/149 CHP 0305 B CHP 0305 P CHP 0305 R CHP 0305 M CHP 0305 S CHP 0305 A
CHP 005 70 41,2 100/250/400 65/149 CHP 0310 B CHP 0310 P CHP 0310 R CHP 0310 M CHP 0310 S CHP 0310 A
CHP 007 130 76,5 100/250/400 65/149 CHP 0420 B CHP 0420 P CHP 0420 R CHP 0420 M CHP 0420 S CHP 0420 A
CHP 010 195 115 100/250/400 65/149 CHP 0520 B CHP 0520 P CHP 0520 R CHP 0520 M CHP 0520 S CHP 0520 A
CHP 018 275 162 100/250/400 65/149 CHP 0525 B CHP 0525 P CHP 0525 R CHP 0525 M CHP 0525 S CHP 0525 A
CHP 030 380 223 100/250/400 65/149 CHP 0725 B CHP 0725 P CHP 0725 R CHP 0725 M CHP 0725 S CHP 0725 A
CHP 047 495 291 100/250/400 65/149 CHP 0730 B CHP 0730 P CHP 0730 R CHP 0730 M CHP 0730 S CHP 0730 A
CHP 094 715 421 100/250/400 65/149 CHP 1030 B CHP 1030 P CHP 1030 R CHP 1030 M CHP 1030 S CHP 1030 A
B P R M S A
solid particle size purification: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change filter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
filter material sintered brass acrile fibres, celulose borosilicate micro fibres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon filters must not operate in oil
saturated conditions.
www.omega-air.si 29
PF series - 16 bar
E
øC
D
B
E
30
PF filter cartridges
www.omega-air.si 31
HPF series - 50 bar
1/2’’
øC
B
1/2’’
32
HPF filter cartridges
www.omega-air.si 33
SF series - 16 bar
øC
A
A
D
B
B
E
34
SF filter cartridges
www.omega-air.si 35
SPF series - 16 bar
SPF filters are therefore made of high quality stainless steel for
pharmaceutical industry (quality 1.4404(316L)). Housing is
polished down to grade Ra 0,8.
SPF 070 1 1/2’’ 600 408 180 114,3 106 1/4’’ 4,3 16 1x0730
D
SPF 094 2’’ 900 476 180 114,3 106 1/4’’ 4,8 16 1x1030
SPF 150 2’’ 1260 602 180 114,3 106 1/4’’ 5,3 16 1x1530
SPF 175 2 1/2’’ 1680 762 224 139,7 121 1/4’’ 9,0 16 1x2030
SPF 200 3’’ 2400 1030 224 139,7 131 1/4’’ 10,8 12 1x3030 B
SPF 240 3’’ 3600 1062 255 168,3 136 1/4’’ 16,2 12 1x3050 E
36
SPF filter cartridges
www.omega-air.si 37
WOS - water - oil sepatators
38
WOS
INLET
» condensate (oil, water)
» air AIR OUTLET
DEPRESSURIZE CHAMBER
nd
2 stage WITH AIR FILTER
chamber
CLEAN WATER
OUTLET
residual oil
» condensate
content <10ppm
(oil, water)
Separator model
WOS-4 WOS-8 WOS-20 WOS-35
Max. capacity of compressed air [m3/h] / [m3/min] 240 / 4 480 / 8 1200 / 20 2100 / 35
Max. oil adsorbtion [Ltr] 3 10 15 25
C
www.omega-air.si 39
Filter cartridges
DOMNICK HUNTER
Size PF AO AA ACS
009 DHPF 009/P DHAO 009/M DHAA 009/S DHACS 009/A
017 DHPF 017/P DHAO 017/M DHAA 017/S DHACS 017/A
030 DHPF 030/P DHAO 030/M DHAA 030/S DHACS 030/A
058 DHPF 058/P DHAO 058/M DHAA 058/S DHACS 058/A
145 DHPF 145/P DHAO 145/M DHAA 145/S DHACS 145/A
220 DHPF 220/P DHAO 220/M DHAA 220/S DHACS 220/A
330 DHPF 330/P DHAO 330/M DHAA 330/S DHACS 330/A
430 DHPF 430/P DHAO 430/M DHAA 430/S DHACS 430/A
620 DHPF 620/P DHAO 620/M DHAA 620/S DHACS 620/A
ZANDER
Size V Y X A
1050 ZV 06050/P ZY 06050/M ZX 06050/S ZA 06050/A
1070 ZV 07050/P ZY 07050/M ZX 07050/S ZA 07050/A
1140 ZV 14050/P ZY 14050/M ZX 14050/S ZA 14050/A
2010 ZV 12075/P ZY 12075/M ZX 12075/S ZA 12075/A
2020 ZV 22075/P ZY 22075/M ZX 22075/S ZA 22075/A
2030 ZV 32075/P ZY 32075/M ZX 32075/S ZA 32075/A
2050 ZV 50075/P ZY 50075/M ZX 50075/S ZA 50075/A
3050 ZV 51090/P ZY 51090/M ZX 51090/S ZA 51090/A
3075 ZV 76090/P ZY 76090/M ZX 76090/S ZA 76090/A
5075 ZV 75140/P ZY 75140/M ZX 75140/S ZA 75140/A
HIROSS
Size Q P S C
004 HQ 004/P HP 004/M HS 004/S HC 004 /A
007 HQ 007/P HP 007/M HS 007/S HC 007/A
015 HQ 015/P HP 015/M HS 015/S HC 015/A
024 HQ 024/P HP 024/M HS 024/S HC 024/A
035 HQ 035/P HP 035/M HS 035/S HC 035/A
060 HQ 060/P HP 060/M HS 060/S HC 060/A
090 HQ 090/P HP 090/M HS 090/S HC 090/A
120 HQ 120/P HP 120/M HS 120/S HC 120/A
150 HQ 150/P HP 150/M HS 150/S HC 150/A
240 HQ 240/P HP 240/M HS 240/S HC 240/A
OMI
Size QF PF HF CF
0004 OQF /P OPF /M OHF /S OCF /A
0008 OQF /P OPF /M OHF /S OCF /A
0016 OQF /P OPF /M OHF /S OCF /A
0025 OQF /P OPF /M OHF /S OCF /A
0036 OQF /P OPF /M OHF /S OCF /A
0060 OQF /P OPF /M OHF /S OCF /A
0070 OQF /P OPF /M OHF /S OCF /A
0090 OQF /P OPF /M OHF /S OCF /A
0120 OQF /P OPF /M OHF /S OCF /A
0185 OQF /P OPF /M OHF /S OCF /A
40
Filter cartridges
www.omega-air.si 41
Process & Sterile filter cartridges
42
Process & Sterile filter cartridges
www.omega-air.si 43
Paint systems
ProPaintsystem
Microfilter
S 0,01μm
M 0,1μm
CKL-PP
A
Connec- Air flow Dimensions (mm)
Model
tions
3
Nm /h A B C
PP-107 1/2’’ 155 270 135 276 • • 2
PP-110 1/2’’ 235 270 135 345 • • 2
PP-207 1/2’’ 78 380 135 276 • • • 2
PP-210 1/2’’ 120 380 135 345 • • • 2
PP-307 1/2’’ 78 490 135 276 • • • • 2
PP-310 1/2’’ 120 490 135 345 • • • • 2
C PP-407 1/2’’ 78 580 135 276 • • • • 4
PP-410 1/2’’ 120 580 135 345 • • • • 4
A PP-507 1/2’’ 78 612 135 370 • • • • 4
PP-510 1/2’’ 120 612 135 440 • • • • 4
• • • • •
B
44
Petrol station equipment
BS 12-3,5
BS 12-1,3/1,7
BS Tower
PETRO-PACK
BS 12
Size BS 12-3.5 PETRO-PACK BS TOWER
1,3 1,7
Flow capacity (ISO 1217) 350 Nl/min 130 Nl/min 170 Nl/min 350 Nl/min -
Operating temperature -15 to +45°C -15 to +45°C -15 to +45°C -15 to +45°C -15 to +45°C
Hose length 8m 8m 8m - 8m
www.omega-air.si 45
Other products
Terrain compressors
Container compressed air units
Oil separators
Pressure vessels
- Horizontal pressure vessels
- Vertical pressure vessels
up to 20.000 litres
46
Omega Air d.o.o. Ljubljana
Jure Robič
Construction
Gojmir Furlan
Technology
Mitja Rihtaršič
Electronics
www.omega-air.si 47
Omega Air d.o.o. Ljubljana
Sandi Pečevnik
Filter cartridges
Marko Perovšek
Moulds construction
Moulds production
48
Production
Mechanical department
Welding department
Plastic department
Service department
Logistics department
Sport club
50
WHERE WE ARE?
Austria Austria
Exit Nr. 35
Europe,
Slovenia
Ljubljana
OMEGA AIR d.o.o. Ljubljana
LJUBLJANA Cesta Dolomitskega odreda 10
SI-1000, Ljubljana, Slovenia
GPS coordinates:
N: 46° 2’ 27.13’’
E: 14° 27’ 59.46’’
CUSTOMISED PRODUCTS
A large part of our manufacturing capacity is suited for customized products. We take part in the developing of the products together with our customers.
If you have a project in our range of products and need a co-operating partner do not hesitate to contact us.
The above mentioned sales terms and conditions are only for information. All other details are defined in writen agreement between contract parties.
www.omega-air.si 51
Concerning all furnished data, we reserve the right to make alterations to the constructive design, dimensions
and technical specifications!