To prepare for the initialization of the array, verify the following requirements have been met:
FLARE Operating Environment (OE) software version 03.22.xxx or higher installed on the storage
system. A card that ships with the storage system tells you the FLARE version installed.
Done
A server on the same subnet (physical LAN segment) as the storage systems management ports
and running one of the operating systems listed below. This server may also be a server with Fibre
Channel connections to the storage system.
VMware ESX Server
HP-UX
Linux
Solaris
Windows 2000
Windows Server 2003
Note: The initialization utility is not available for AIX servers.The customers LAN port is set to
auto-negotiate. The management LAN port on CLARiiON arrays is hard-set to auto-negotiate and
cannot be changed to half- or full-duplex to accommodate different customer LAN port settings.
For more information, refer to EMC Knowledgebase article emc79617.
.2
You will need an IP address assigned for each SP and the server/laptop that will be used to run the
Initialization Wizard. Gather the following information:
IP Address of laptop (if running Initialization Wizard from laptop): ___________________
Storage System Information
Storage system serial number (see note below):
Network Information
IP address
Subnet mask
Gateway
SP A:
SP A:
SP A:
SP B:
SP B:
SP B:
Login Information
Username:
Password:
Role:
Monitor
Manager
Administrator
Security Administrator
Note: The hardware serial number (TLA S/N) is on a blue horizontal label that is located under power
supply A on the far left of the chassis behind the front bezel (front panel), as shown below:
Figure 1
.3
Connect your laptop or server (from which running the Initialization Wizard) to the LAN (same subnet)
as the 2 SPs.
.4
.5
Figure 2