SIRIUS IC10AO Complete English 2014 PDF
SIRIUS IC10AO Complete English 2014 PDF
SIRIUS IC10AO Complete English 2014 PDF
Industrial Controls
SIRIUS 3R_1* in sizes S00/S0 to S12
SIRIUS
Catalog
Add-On
IC 10 AO
Edition
2014
Siemens AG 2014
Related catalogs
Miscellaneous
IC 10
Industrial Controls
SIRIUS
E86060-K1010-A101-A4-7600
E86060-D4001-A510-D3-7600
Industry Mall
Information and Ordering Platform
in the Internet:
E86060-K8280-A101-A1-7600
www.siemens.com/industrymall
Safety Integrated
Safety Technology for
Factory Automation
SI 10
E86060-K7010-A101-A3-7600
Industrial Communication
SIMATIC NET
www.siemens.com/sirius/catalogs
IK PI
Response E-mail
Please send your comments and suggestions
for improvement to
catalogs.industry@siemens.com
(include the catalog name in the subject field)
E86060-K6710-A101-B7-7600
SIMATIC
Products for
Totally Integrated Automation
ST 70
E86060-K4670-A101-B4-7600
SIMOTICS Low-Voltage Motors
Type series 1LE1, 1MB1 and 1PC1
Frame sizes 80 to 315
Power range 0.3 to 250 kW
CA 01
D 81.1
E86060-K5581-A111-A6-7600
SITRAIN
Training for Industry
ITC
Registered trademarks
Technical Assistance
Registered trademarks
All product designations may be registered trademarks or
product names of Siemens AG or other supplying companies.
Third parties using these trademarks or product names for their
own purposes may infringe upon the rights of the trademark
owners.
Technical Assistance
Expert technical assistance
for Industrial controls:
Tel.: +49 (911) 895-5900
Fax: +49 (911) 895-5907
E-Mail: technicalassistance@siemens.com
Siemens AG 2014
SIRIUS
Industrial Controls
Introduction
Industrial Communication
Switching Devices
Contactors and Contactor Assemblies
for Switching Motors
Switching Devices
Contactors and Contactor Assemblies
for Special Applications
Switching Devices
Contactors and Contactor Assemblies
Contactor Relays and Relays
Switching Devices
Soft Starters and
Solid-State Switching Devices
Protection Equipment
10
Safety Technology
11
12
13
14
15
Appendix
16
Supersedes:
Catalog Add-On IC 10 AO 2013
Siemens AG 2014
SIRIUS
Industrial Controls
Catalog Add-On IC 10 AO 2014
Dear Customer,
You have decided not to switch to SIRIUS Innovations for the time being, and are currently still using SIRIUS 3R_1* in sizes S00/S0
to S12. We are therefore pleased to be able to make this Catalog Add-On IC 10 AO 2014 to you as an e-book.
In Chapters 3, 4, 5, 7, 8, 9 and 11 the Catalog Add-On describes your tried and tested SIRIUS modular
system with a portfolio of products and solutions for switching and protection functions.
If you are interested in switching to SIRIUS Innovations in the near future, we will naturally be happy to offer
you our new Catalog IC 10 2014. Please contact your local Siemens office if necessary.
You will find up-to-date information on Industrial Controls on the Internet at www.siemens.com/sirius, and
access to the interactive catalog and to the Industry Mall at www.siemens.com/industrymall.
We hope that the Catalog Add-On IC 10 AO will serve as a selection and ordering document that you will use often and with
pleasure, and wish you every success with our products and solutions. We will be glad to receive your suggestions and
recommendations for improvement (please make reference to the catalog name) under catalogs.industry@siemens.com.
Best regards,
Michael Freyny
Head of Sales
I IA CE S
Christoph Hotz
Head of Marketing and Strategy
I IA CE MK&ST
Siemens AG 2014
Price groups
PG 41B, 41H
3/5
3/11
3/26
3/28
3/49
Introduction
Power contactors
for switching motors
General data
SIRIUS 3RT10 contactors, 3-pole,
3 ... 250 kW
SIRIUS 3RT12 vacuum contactors,
3-pole, 110 ... 250 kW
Accessories for 3RT1 contactors
Spare parts for 3RT1 contactors
3/54
Coupling contactors
SIRIUS 3RT10 coupling contactors
(interface), 3-pole, 3 ... 11 kW
3/58
Contactor assemblies
3RA13, 3RA14 contactor assemblies
SIRIUS 3RA13 reversing contactor
assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
3/66
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
3/2
Siemens AG 2014
Overview
Size
Type
S00
3RT101
S0
3RT102
S2
3RT103
3RT10 contactors
Type
AC, DC operation
3RT1015 3RT1016
(p. 3/14, 3/18)
3RT1017
3RT1023 3RT1024
(p. 3/15, 3/19)
3RT1025
3RT1026
3RT1034 3RT1035
(p. 3/16, 3/20)
3RT1036
17
25
32
40
50
11
15
18.5
22
5.5
11
11
--
7.5
18.5
18.5
--
11
22
22
--
15
30
22
--
7.5
4.4
15
8.2
18.5
9.5
22
12.6
50
60
60
AC-3
Ie/AC-3/400 V
400 V
kW
5.5
5.5
230 V
500 V
690 V
1 000 V
kW
kW
kW
kW
2.2
3.5
4
--
3
4.5
5.5
--
3
5.5
5.5
--
3
4.5
5.5
--
3
7.5
7.5
--
4
2
4
2
4
2
5.5
2.6
22
22
40
3RT10/12
3RT10/12
12
12
7.5
4
10
11
--
kW
kW
3
1.15
7.5
3.5
Ie
18
40
40
40
--
--
--
--
On front
Lateral
(p. 3/34)
(p. 3/38)
3RH1911
--
(p. 3/34)
(p. 3/38)
3RH1921
3RH1921
3RH1921
3RH1921
(p. 3/34)
(p. 3/38)
(p. 3/46)
Terminal covers
--
--
3RT1936-4EA2
--
--
--
Surge suppressors
3RT1916
(p. 3/42)
(p. 3/42)
3RT1926
3RT1926/36
(p. 3/43)
3RU1116
0.1 ... 12 A
(Chap. 7)
3RU1126
3RU1136
3RB20/21, solid-state,
CLASS 5, 10, 20 and 30
3RB2016
3RB2116
0.1 ... 12 A
(Chap. 7)
3RB2026
3RB2126
3 ... 25 A
3RB2036
3RB2136
6 ... 50 A
3RB22/23, solid-state,
CLASS 5, 10, 20 and 30
3RB2.83 + 3RB2906
10 ... 100 A (Chap. 7)
(Chap. 7)
3RB2.83 + 3RB2906
10 ... 100 A (Chap. 7)
(Chap. 7)
3RB2.83 + 3RB2906
10 ... 100 A (Chap. 7)
3RV1011
3RV1021
Link modules
3RA1911
(Chap. 5)
3RA1921
9 ... 25 A
(Chap. 7)
3RV1031
(Chap. 7)
3RA1931
22 ... 50 A
(Chap. 7)
(Chap. 7)
Type 3RA1315
(p. 3/59)
3RA1316
3RA1317
400 V
kW
5.5
3RA1324
(p. 3/60)
3RA1325
3RA1326
3RA1334
(p. 3/61)
3RA1335
3RA1336
5.5
7.5
11
15
18.5
22
3RA1913-2A
(p. 3/64)
3RA1923-2A
(p. 3/64)
3RA1933-2A
Mechanical interlocks
3RA1912-2H
(p. 3/63)
3RA1924-1A/-2B
(p. 3/63)
(p. 3/64)
3RA1924-1A/-2B
(p. 3/63)
3RA1423
(p. 3/69)
3RA1425
3RA1434
(p. 3/70)
3RA1435
(p. 3/71)
3RA1436
11
15/18.5
22/30
37
45
3RA1923-2B
(p. 3/73)
3RA1933-2B/-2C
3/63
Type 3RA1415
(p. 3/68)
3RA1416
400 V
kW
7.5
3/2
5.5
3RA1913-2B
Siemens IC 10 AO 2014
(p. 3/73)
(p. 3/73)
Siemens AG 2014
Introduction
S3
3RT1.4
S6
3RT1.5
S10
3RT1.6
S12
3RT1.7
3RT1046
3RT1054
(p. 3/22)
3RT1055
3RT1056
3RT1064
(p. 3/22)
3RT1065
3RT1066
3RT1075
(p. 3/22)
3RT1076
3RT1264
(p. 3/27)
3RT1265
3RT1266
3RT1275
(p. 3/27)
3RT1276
65
80
95
115
150
185
225
265
300
400
500
30
37
45
55
75
90
110
132
160
200
250
18.5
37
45
30
22
45
55
37
22
55
55
37
37
75
110
75
45
90
132
90
55
110
160
90
55
160
200
90/315
75
160
250
132/355
90
200
250
132/400
132
250
400
250/560
160
355
400/500
250/710
30
15.1
37
17.9
45
22
55
29
75
38
90
45
110
54/78
132
66/93
160
71/112
200
84/140
250
98/161
120
160
185
215
275/330
330
330
430/610
610
3RT1476
(Chap. 4)
100
120
3RT1446
140
(Chap. 4)
3RT1456
275
(Chap. 4)
3RT1466
400
690
(p. 3/34)
(p. 3/38)
3RT1946-4EA1/2
(p. 3/46)
-(p. 3/43)
3RT1926/36
3RH1921
3RH1921
(p. 3/34)
(p. 3/38)
3RT1956-4EA1/2/3
(p. 3/46)
3RT1966-4EA1/2/3
(p. 3/46)
3RT1955/56-4G
(p. 3/46)
3RT1966-4G
(p. 3/46)
18 ... 100 A
3RB2046
3RB2146
3RB2.83 + 3RB2906
10 ... 100 A
(Chap. 7)
(Chap. 7)
--
(Chap. 7)
3RB2.83 + 3RB2956
20 ... 200 A
(Chap. 7)
3RB2056
3RB2156
(Chap. 7)
3RB2.83 + 3RB2966
63 ... 630 A
(Chap. 7)
3RB2066
3RB2166
3RB2066
3RB2166
45 ... 100 A
3RA1941
(Chap. 7)
--
--
--
(Chap. 7)
--
--
--
--
--
3RA1345
3RA1346
--
30
37
45
55
90
110
160
200
3RA1943-2A
(p. 3/64)
3RA1953-2A
75
(p. 3/64)
3RA1963-2A
132
(p. 3/64)
250
3RA1924-1A/-2B
(p. 3/63)
3RA1954-2A
(p. 3/63)
3RA1954-2A
(p. 3/63)
3RA1445
55
75
3RA1943-2B/-2C
--
--
-(p. 3/73)
3RA1953-2B
--
-(p. 3/73)
3RA1963-2B
-(p. 3/73)
Siemens IC 10 AO 2014
3/3
Siemens AG 2014
Screw terminals
Spring-type terminals
The terminals are indicated in the corresponding
tables by the symbols shown on orange backgrounds.
3/4
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
The SIRIUS family of controls
The SIRIUS modular system with its components for the
switching, starting, protection and monitoring of motors and
industrial systems stands for the fast, flexible and space-saving
construction of control cabinets.
18
4
12
1
6
19
13
20
2
8
10
11
21
15
16
NSB0_00448c
14
1 Contactor
2 Coupling contactor
3 Solid-state timing relay block, ON-delay
4 Solid-state timing relay block, OFF-delay
5 Auxiliary switch block with solid-state time delay
(ON or OFF-delay or wye-delta function)
6 1-pole auxiliary switch block, cable entry from above
7 2-pole auxiliary switch block, cable entry from above
8 1-pole auxiliary switch block, cable entry from below
9 2-pole auxiliary switch block, cable entry from below
10 4-pole auxiliary switch block
(terminal designations according to EN 50012 or EN 50005)
11 2-pole auxiliary switch block, standard version or solid-state compatible
version (terminal designations according to EN 50005)
12 Solder pin adapter for contactors with 4-pole auxiliary switch block
13 Solder pin adapter for contactors and coupling contactors
For contactors
For contactors and coupling contactors (interface)
3/5
Siemens AG 2014
17
21
11
18
22
10
16
25
12
1
14
1
6
9
15
21
19
23
8
16
22
3
13
26
NSB0_00449c
24
20
1 Contactor, size S0
2 Contactor, size S2
3 Contactor, size S3
For sizes S0 to S3:
4
5
6
7
8
9
10
11
12
13
3/6
Siemens IC 10 AO 2014
Siemens AG 2014
9
7
10
3
11
5
NSB0_01157d
3RT10 and 3RT14 air-break contactors, sizes S6, S10 and S12
3
4
5
6
7
Surge suppressor (RC element) for plugging into top of withdrawable coil
Siemens IC 10 AO 2014
3/7
Siemens AG 2014
1
2
6
1
NSB0_01668c
3/8
Siemens IC 10 AO 2014
Siemens AG 2014
1
2
5
1
NSB0_01669c
3RT10 and 3RT14 air-break contactor, sizes S6, S10 and S12 or
3RT12 vacuum contactor, sizes S10 and S12
2
3
4
5
6
Siemens IC 10 AO 2014
3/9
Siemens AG 2014
3
4
5
NSB0_01410c
3/10
Siemens IC 10 AO 2014
Siemens AG 2014
Standards
Note:
Surge suppression
Connection methods
The 3RT1 contactors are available with screw terminals
(box terminals) or spring-type terminals.
The size S3 contactors have removable box terminals for the
main conductor connections. This permits connection of ring
terminal lugs or busbars.
Contact reliability
If voltages 110 V and currents 100 mA are to be switched,
the auxiliary contacts of the 3RT1 contactor or 3RH11 contactor
relay should be used as they guarantee a high level of contact
reliability.
These auxiliary contacts are particularly suitable for solid-state
circuits with currents 1 mA at a voltage 17 V.
The surge suppressors are plugged onto the front of size S00
contactors. Space is provided for them next to a snap-on
auxiliary switch block.
For size S0 to S3 contactors, varistors and RC elements can be
snapped on either on the top or directly below the coil terminals.
Diode assemblies are available in 2 different versions on account of their polarity. Depending on the application they can be
connected either only at the bottom (assembly with motor starter
protector) or only at the top (assembly with overload relay).
The plug-in direction of the diodes and diode assemblies is
specified by coding.
Exceptions:
3RT1926-1T.00 and 3RT1936-1T.00,
in this case the plug-in direction is marked with "+" and "-".
To assemble fuseless motor feeders you must select combinations of motor starter protector and contactor as explained in
"Fuseless Load Feeders".
Motor protection
Withdrawable coils
The quoted rating (in kW) refers to the output power on the motor
shaft (according to the nameplate).
Surge suppression
3RT1 contactors can be retrofitted with RC elements, varistors,
diodes or diode assemblies (assembly of diode and Zener diode
for short break times) for damping opening surges in the coil.
Note:
For sizes S0 to S3, there are also complete units with mounted
auxiliary switch blocks 2 NO + 2 NC (terminal designation
according to EN 50012); the auxiliary switch block can be
removed (for further information see Accessories, page 3/28).
The solenoid coil is switched directly on and off with the control
supply voltage Us by way of terminals A1/A2.
Only one coil covers several close-lying control supply voltages
which are used worldwide, e.g. 110115120127 V AC/DC or
220230240 V AC/DC. Allowance is made in addition for an
operating range of 0.8 times the lower (Us min) and 1.1 times the
upper (Us max) rated control supply voltage within which the
contactor switches reliably and no thermal overload occurs.
Siemens IC 10 AO 2014
3/11
Overview
Siemens AG 2014
new
60 %
40 %
20 %
green
RLT
RLT
RLT
RLT
green
60 %
60 %
60 %
60 %
orange
40 %
40 %
40 %
40 %
red
20 %
20 %
20 %
20 %
Reset
Reset
Reset
Reset
NSB0_01150a
LED
displays
PLC output
24 V DC/30 mA
Note:
A1 A2
24 V DC
PLC
OFF ON
NSB0_01143e
Advantages:
Signaling through relay contact when remaining lifetime is
20 %, i.e. contact material wear is 80 %
Additional visual indication of various levels of erosion by
means of LEDs on the laterally mounted solid-state module
when remaining lifetime is 60 % (green), 40 % (orange) and
20 % (red).
Note:
Shutdown in an emergency
(EMERGENCY-STOP) optional
A1 A2
24 V DC
1
PLC
OFF ON
NSB0_01144e
Note:
The slide switch must be in the "PLC OFF" position
(= setting ex works).
3/12
Siemens IC 10 AO 2014
Siemens AG 2014
A1
50-60 Hz
DC
L1/L+
N/L-
A2
60 %
40 %
20 %
Reset
R1
R2
IN
IN
300 V
AC/DC
R1
R2
IN
RLT
3RT105/3RT145
NSB0_01145b
24 V
DC
IN
S1
NSB0_01146f
Plug-in
connection
7-pole
Solid-state module of
3RT1...-.P contactor
S1 Changeover switch from automatic control using PLC semiconductor output to local control
S2
S1
H1
H2
RLT
H1
H2
A1 A2
Contactor ON
ON
-.PP3.
200-277 V
3
S1
A1 A2
H1
H2
S2
R1
R2
IN
IN
Solid-state module of
3RT1...-.P contactor
NSB0_01147e
3RT
1st generation
1
@
3RT
Siemens IC 10 AO 2014
3/13
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT101.-1AP04-3MA0
3RT101.-2AP04-3MA0
Rated data
Auxiliary contacts
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
400 V
400 V
690 V
kW
3RT101.-1A. . .
Version
NO
3RT101.-2A. . .
DT Screw terminals
Rated control
supply voltage
Us at 50/60 Hz
NC
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
V AC
A1(+)
A2()
18
22
12
5.5
22
10
--
24
110
230
}
}
}
3RT1015-1AB01
3RT1015-1AF01
3RT1015-1AP01
}
}
}
3RT1015-2AB01
3RT1015-2AF01
3RT1015-2AP01
01
--
24
110
230
}
}
}
3RT1015-1AB02
3RT1015-1AF02
3RT1015-1AP02
}
}
}
3RT1015-2AB02
3RT1015-2AF02
3RT1015-2AP02
10
--
24
110
230
}
}
}
3RT1016-1AB01
3RT1016-1AF01
3RT1016-1AP01
}
}
}
3RT1016-2AB01
3RT1016-2AF01
3RT1016-2AP01
01
--
24
110
230
}
}
}
3RT1016-1AB02
3RT1016-1AF02
3RT1016-1AP02
}
}
}
3RT1016-2AB02
3RT1016-2AF02
3RT1016-2AP02
10
--
24
110
230
}
}
}
3RT1017-1AB01
3RT1017-1AF01
3RT1017-1AP01
}
}
}
3RT1017-2AB01
3RT1017-2AF01
3RT1017-2AP01
01
--
24
110
230
}
}
}
3RT1017-1AB02
3RT1017-1AF02
3RT1017-1AP02
B
}
}
3RT1017-2AB02
3RT1017-2AF02
3RT1017-2AP02
18
22
230
3RT1015-1AP04-3MA0
3RT1015-2AP04-3MA0
22
22
230
3RT1016-1AP04-3MA0
3RT1016-2AP04-3MA0
12
5.5
22
22
230
3RT1017-1AP04-3MA0
3RT1017-2AP04-3MA0
3/14
Siemens IC 10 AO 2014
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2)
For size S00: Coil operating range
at 50 Hz: 0.8 ... 1.1 Us,
at 60 Hz: 0.85 ... 1.1 Us.
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT102.-1A.04
3RT102.-1AL24-3MA0
Rated data
Auxiliary contacts
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
400 V
400 V
690 V
kW
3RT102.-1A.00
Version
NO
3RT102.-3A.00
DT Screw terminals
Rated control
supply voltage
Us at 50 Hz
NC
Article No.
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
V AC
401)
--
--
--
24
110
230
}
}
}
3RT1023-1AB00
3RT1023-1AF00
3RT1023-1AP00
B
B
}
3RT1023-3AB00
3RT1023-3AF00
3RT1023-3AP00
12
5.5
401)
--
--
--
24
110
230
}
}
}
3RT1024-1AB00
3RT1024-1AF00
3RT1024-1AP00
B
B
}
3RT1024-3AB00
3RT1024-3AF00
3RT1024-3AP00
17
7.5
401)
--
--
--
24
110
230
}
}
}
3RT1025-1AB00
3RT1025-1AF00
3RT1025-1AP00
B
B
}
3RT1025-3AB00
3RT1025-3AF00
3RT1025-3AP00
25
11
401)
--
--
--
24
110
230
}
}
}
3RT1026-1AB00
3RT1026-1AF00
3RT1026-1AP00
B
B
}
3RT1026-3AB00
3RT1026-3AF00
3RT1026-3AP00
403)
22
24
110
230
}
}
}
3RT1023-1AB04
3RT1023-1AF04
3RT1023-1AP04
----
12
5.5
403)
22
24
110
230
}
}
}
3RT1024-1AB04
3RT1024-1AF04
3RT1024-1AP04
----
17
7.5
403)
22
24
110
230
}
}
}
3RT1025-1AB04
3RT1025-1AF04
3RT1025-1AP04
----
25
11
403)
22
24
110
230
}
}
}
3RT1026-1AB04
3RT1026-1AF04
3RT1026-1AP04
----
At 50/60 Hz
V AC
12
5.5
401)
22
230
3RT1024-1AL24-3MA0
--
17
7.5
401)
22
230
3RT1025-1AL24-3MA0
--
25
11
401)
22
230
3RT1026-1AL24-3MA0
--
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2)
Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC according to EN 50012; 22).
3) Minimum conductor cross-section 10 mm.
Siemens IC 10 AO 2014
3/15
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT103.-1A.04
Rated data
3RT103.-1A.00
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
500 V
400 V
690 V
kW
Version
NO
3RT103.-3A.00
DT Screw terminals
Rated control
supply voltage
Us at 50 Hz
Auxiliary contacts
NC
Article No.
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
V AC
32
15
50
--
--
--
24
110
230
}
}
}
3RT1034-1AB00
3RT1034-1AF00
3RT1034-1AP00
B
B
}
3RT1034-3AB00
3RT1034-3AF00
3RT1034-3AP00
40
18.5
60
--
--
--
24
110
230
}
}
}
3RT1035-1AB00
3RT1035-1AF00
3RT1035-1AP00
B
B
}
3RT1035-3AB00
3RT1035-3AF00
3RT1035-3AP00
50
22
60
--
--
--
24
110
230
}
}
}
3RT1036-1AB00
3RT1036-1AF00
3RT1036-1AP00
B
B
}
3RT1036-3AB00
3RT1036-3AF00
3RT1036-3AP00
32
15
50
22
24
110
230
}
}
}
3RT1034-1AB04
3RT1034-1AF04
3RT1034-1AP04
----
40
18.5
60
22
24
110
230
}
}
}
3RT1035-1AB04
3RT1035-1AF04
3RT1035-1AP04
----
50
22
60
22
24
110
230
}
}
}
3RT1036-1AB04
3RT1036-1AF04
3RT1036-1AP04
----
32
15
50
22
230
3RT1034-1AP04-3MA0
--
40
18.5
60
22
230
3RT1035-1AP04-3MA0
--
50
22
60
22
230
3RT1036-1AP04-3MA0
--
3/16
Siemens IC 10 AO 2014
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2)
Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC acc. to EN 50012; Ident. No. 22).
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT104.-1A.04
Rated data
3RT104.-1A.00
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
500 V
400 V
690 V
kW
Version
NO
3RT104.-3A.00
DT Screw terminals
Rated control
supply voltage
Us at 50 Hz
Auxiliary contacts
Article No.
NC
V AC
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
65
30
100
--
--
--
24
110
230
}
}
}
3RT1044-1AB00
3RT1044-1AF00
3RT1044-1AP00
B
B
}
3RT1044-3AB00
3RT1044-3AF00
3RT1044-3AP00
80
37
120
--
--
--
24
110
230
}
}
}
3RT1045-1AB00
3RT1045-1AF00
3RT1045-1AP00
B
B
}
3RT1045-3AB00
3RT1045-3AF00
3RT1045-3AP00
95
45
120
--
--
--
24
110
230
}
}
}
3RT1046-1AB00
3RT1046-1AF00
3RT1046-1AP00
B
B
}
3RT1046-3AB00
3RT1046-3AF00
3RT1046-3AP00
65
30
100
22
24
110
230
}
}
}
3RT1044-1AB04
3RT1044-1AF04
3RT1044-1AP04
----
80
37
120
22
24
110
230
B
}
}
3RT1045-1AB04
3RT1045-1AF04
3RT1045-1AP04
----
95
45
120
22
24
110
230
B
}
}
3RT1046-1AB04
3RT1046-1AF04
3RT1046-1AP04
----
65
30
100
22
230
3RT1044-1AP04-3MA0
--
80
37
120
22
230
3RT1045-1AP04-3MA0
--
95
45
120
22
230
3RT1046-1AP04-3MA0
--
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2) Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC acc. to EN 50012; Ident. No. 22).
Siemens IC 10 AO 2014
3/17
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT101.-1BB44-3MA0
3RT101.-2BB44-3MA0
Rated data
Auxiliary contacts
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
400 V
400 V
690 V
kW
3RT101.-1B. . .
Version
NO
3RT101.-2B. . .
Rated control
DT Screw terminals
supply voltage
Us
NC
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
V DC
A1(+)
A2()
18
22
12
5.5
22
10
--
24
220
}
A
3RT1015-1BB41
3RT1015-1BM41
}
B
3RT1015-2BB41
3RT1015-2BM41
01
--
24
220
}
B
3RT1015-1BB42
3RT1015-1BM42
}
B
3RT1015-2BB42
3RT1015-2BM42
10
--
24
220
}
B
3RT1016-1BB41
3RT1016-1BM41
}
B
3RT1016-2BB41
3RT1016-2BM41
01
--
24
220
}
B
3RT1016-1BB42
3RT1016-1BM42
}
B
3RT1016-2BB42
3RT1016-2BM42
10
--
24
220
}
B
3RT1017-1BB41
3RT1017-1BM41
}
B
3RT1017-2BB41
3RT1017-2BM41
01
--
24
220
}
B
3RT1017-1BB42
3RT1017-1BM42
}
B
3RT1017-2BB42
3RT1017-2BM42
18
22
24
3RT1015-1BB44-3MA0
3RT1015-2BB44-3MA0
22
22
24
3RT1016-1BB44-3MA0
3RT1016-2BB44-3MA0
12
5.5
22
22
24
3RT1017-1BB44-3MA0
3RT1017-2BB44-3MA0
1)
3/18
Siemens IC 10 AO 2014
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT102.-3B.44
3RT102.-1BB44-3MA0
Rated data
Auxiliary contacts
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
400 V
400 V
690 V
kW
3RT102.-1B.40
Version
NO
3RT102.-3B.40
Rated control
DT Screw terminals
supply voltage
Us
NC
Article No.
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
V DC
401)
--
--
--
24
220
}
B
3RT1023-1BB40
3RT1023-1BM40
}
B
3RT1023-3BB40
3RT1023-3BM40
12
5.5
401)
--
--
--
24
220
}
A
3RT1024-1BB40
3RT1024-1BM40
}
B
3RT1024-3BB40
3RT1024-3BM40
17
7.5
401)
--
--
--
24
220
}
A
3RT1025-1BB40
3RT1025-1BM40
}
B
3RT1025-3BB40
3RT1025-3BM40
25
11
401)
--
--
--
24
220
}
A
3RT1026-1BB40
3RT1026-1BM40
}
B
3RT1026-3BB40
3RT1026-3BM40
2)
403)
22
24
220
}
B
3RT1023-1BB44
3RT1023-1BM44
---
12
5.5
403)
22
24
220
}
B
3RT1024-1BB44
3RT1024-1BM44
---
17
7.5
403)
22
24
220
}
B
3RT1025-1BB44
3RT1025-1BM44
---
25
11
403)
22
24
220
}
B
3RT1026-1BB44
3RT1026-1BM44
---
12
5.5
401)
22
24
3RT1024-1BB44-3MA0
--
17
7.5
401)
22
24
3RT1025-1BB44-3MA0
--
25
11
401)
22
24
3RT1026-1BB44-3MA0
--
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2) Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC according to EN 50012; 22E).
3)
Minimum conductor cross-section 10 mm.
Siemens IC 10 AO 2014
3/19
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT103.-1B.44
Rated data
3RT103.-1B.40
Auxiliary contacts
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
500 V
400 V
690 V
kW
Version
NO
3RT103.-3B.40
Rated control
DT Screw terminals
supply voltage
Us
NC
Article No.
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
V DC
32
15
50
--
--
--
24
220
}
B
3RT1034-1BB40
3RT1034-1BM40
}
B
3RT1034-3BB40
3RT1034-3BM40
40
18.5
60
--
--
--
24
220
}
B
3RT1035-1BB40
3RT1035-1BM40
}
B
3RT1035-3BB40
3RT1035-3BM40
50
22
60
--
--
--
24
220
}
B
3RT1036-1BB40
3RT1036-1BM40
}
B
3RT1036-3BB40
3RT1036-3BM40
32
15
50
22
24
220
}
B
3RT1034-1BB44
3RT1034-1BM44
---
40
18.5
60
22
24
220
}
B
3RT1035-1BB44
3RT1035-1BM44
---
50
22
60
22
24
220
}
B
3RT1036-1BB44
3RT1036-1BM44
---
32
15
50
22
24
3RT1034-1BB44-3MA0
--
40
18.5
60
22
24
3RT1035-1BB44-3MA0
--
50
22
60
22
24
3RT1036-1BB44-3MA0
--
3/20
Siemens IC 10 AO 2014
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2)
Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC acc. to EN 50012; Ident. No. 22).
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT104.-1B.44
Rated data
AC-2 and AC-3,
Tu: Up to 60 C
Rated control
DT Screw terminals
supply voltage
Us
AC-1,
Tu: 40 C
Operational
current Ie
up to
Rating1) of
three-phase
motors at
50 Hz and
OperaIdent. No.
tional
current Ie
up to
500 V
400 V
690 V
kW
Version
NO
3RT104.-3B.40
3RT104.-1B.40
Auxiliary contacts
Article No.
NC
V DC
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
65
30
100
--
--
--
24
220
}
B
3RT1044-1BB40
3RT1044-1BM40
}
B
3RT1044-3BB40
3RT1044-3BM40
80
37
120
--
--
--
24
220
}
B
3RT1045-1BB40
3RT1045-1BM40
}
B
3RT1045-3BB40
3RT1045-3BM40
95
45
120
--
--
--
24
220
}
B
3RT1046-1BB40
3RT1046-1BM40
}
B
3RT1046-3BB40
3RT1046-3BM40
65
30
100
22
24
220
}
B
3RT1044-1BB44
3RT1044-1BM44
---
80
37
120
22
24
220
}
B
3RT1045-1BB44
3RT1045-1BM44
---
95
45
120
22
24
220
}
B
3RT1046-1BB44
3RT1046-1BM44
---
65
30
100
22
24
3RT1044-1BB44-3MA0
--
80
37
120
22
24
3RT1045-1BB44-3MA0
--
95
45
120
22
24
3RT1046-1BB44-3MA0
--
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
2) Article No. for the auxiliary switch block (removable): 3RH1921-1HA22
(2 NO + 2 NC acc. to EN 50012; Ident. No. 22).
Siemens IC 10 AO 2014
3/21
Siemens AG 2014
3RT1.5.
Size
3RT1.6.
Rated data
3RT1.7.
Auxiliary
contacts,
AC-1,
Tu: 40 C lateral
Ratings2) of
three-phase motors
at 50 Hz and
500 V
230 V
400 V
500 V
690 V
690 V
kW
kW
kW
kW
Rated control
DT Article No.
supply voltage
Us
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
OperaVersion
tional
current Ie
up to
NO
NC
V AC/DC
S6
S10
S12
A1(+)
A2()
Screw terminals
115
37
55
75
110
160
110 127
220 240
}
}
3RT1054-1AF36
3RT1054-1AP36
1
1
1 unit
1 unit
41B
41B
150
45
75
90
132
185
110 127
220 240
}
}
3RT1055-6AF36
3RT1055-6AP36
1
1
1 unit
1 unit
41B
41B
185
55
90
110
160
215
110 127
220 240
}
}
3RT1056-6AF36
3RT1056-6AP36
1
1
1 unit
1 unit
41B
41B
225
55
110
160
200
275
110 127
220 240
}
}
3RT1064-6AF36
3RT1064-6AP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
110 127
220 240
}
}
3RT1065-6AF36
3RT1065-6AP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
110 127
220 240
}
}
3RT1066-6AF36
3RT1066-6AP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
430
110 127
220 240
}
}
3RT1075-6AF36
3RT1075-6AP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
400
610
110 127
220 240
}
}
3RT1076-6AF36
3RT1076-6AP36
1
1
1 unit
1 unit
41B
41B
Spring-type
terminals
for coil and auxiliary
switch terminals
S6
S10
S12
115
37
55
75
110
160
110 127
220 240
B
B
3RT1054-3AF36
3RT1054-3AP36
1
1
1 unit
1 unit
41B
41B
150
45
75
90
132
185
110 127
220 240
B
B
3RT1055-2AF36
3RT1055-2AP36
1
1
1 unit
1 unit
41B
41B
185
55
90
110
160
215
110 127
220 240
B
B
3RT1056-2AF36
3RT1056-2AP36
1
1
1 unit
1 unit
41B
41B
225
55
110
160
200
275
110 127
220 240
B
B
3RT1064-2AF36
3RT1064-2AP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
110 127
220 240
B
B
3RT1065-2AF36
3RT1065-2AP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
110 127
220 240
B
B
3RT1066-2AF36
3RT1066-2AP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
430
110 127
220 240
B
B
3RT1075-2AF36
3RT1075-2AP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
400
610
110 127
220 240
B
B
3RT1076-2AF36
3RT1076-2AP36
1
1
1 unit
1 unit
41B
41B
3/22
Siemens IC 10 AO 2014
1)
Alternatively the 3RT1054-1 contactor (55 kW) can be supplied with busbar connections instead of box terminals. Without additional price.
In the 8th position of the Article No., the "1" must be replaced with "6" for
screw terminals, e.g. 3RT1054-6A.36; for spring-type terminals, the "3"
must be replaced by "2", e.g. 3RT1054-2A.36.
2)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
Siemens AG 2014
3RT1.5.
Size
3RT1.6.
Rated data
3RT1.7.
Auxiliary
contacts,
AC-1,
Tu: 40 C lateral
Ratings2) of
three-phase motors
at 50 Hz and
500 V
230 V
400 V
500 V
690 V
690 V
kW
kW
kW
kW
Rated control
DT Article No.
supply voltage
Us
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
OperaVersion
tional
current Ie
up to
NO
NC
V AC/DC
S6
S10
S12
A1(+)
A2()
Screw terminals
115
37
55
75
110
160
96 127
200 277
A
}
3RT1054-1NF36
3RT1054-1NP36
1
1
1 unit
1 unit
41B
41B
150
45
75
90
132
185
96 127
200 277
A
}
3RT1055-6NF36
3RT1055-6NP36
1
1
1 unit
1 unit
41B
41B
185
55
90
110
160
215
96 127
200 277
A
}
3RT1056-6NF36
3RT1056-6NP36
1
1
1 unit
1 unit
41B
41B
225
55
110
160
200
275
96 127
200 277
A
A
3RT1064-6NF36
3RT1064-6NP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
96 127
200 277
A
A
3RT1065-6NF36
3RT1065-6NP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
96 127
200 277
B
A
3RT1066-6NF36
3RT1066-6NP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
430
96 127
200 277
A
A
3RT1075-6NF36
3RT1075-6NP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
400
610
96 127
200 277
A
A
3RT1076-6NF36
3RT1076-6NP36
1
1
1 unit
1 unit
41B
41B
Spring-type
terminals
for coil and auxiliary
switch terminals
S6
S10
S12
115
37
55
75
110
160
96 127
200 277
B
B
3RT1054-3NF36
3RT1054-3NP36
1
1
1 unit
1 unit
41B
41B
150
45
75
90
132
185
96 127
200 277
B
B
3RT1055-2NF36
3RT1055-2NP36
1
1
1 unit
1 unit
41B
41B
185
55
90
110
160
215
96 127
200 277
B
B
3RT1056-2NF36
3RT1056-2NP36
1
1
1 unit
1 unit
41B
41B
225
55
110
160
200
275
96 127
200 277
B
B
3RT1064-2NF36
3RT1064-2NP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
96 127
200 277
B
B
3RT1065-2NF36
3RT1065-2NP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
96 127
200 277
B
B
3RT1066-2NF36
3RT1066-2NP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
430
96 127
200 277
B
B
3RT1075-2NF36
3RT1075-2NP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
400
610
96 127
200 277
B
B
3RT1076-2NF36
3RT1076-2NP36
1
1
1 unit
1 unit
41B
41B
1)
Siemens IC 10 AO 2014
3/23
Siemens AG 2014
3RT1056-6P. .
Size
Rated data
Auxiliary
contacts,
AC-1,
Tu: 40 C lateral
Ratings2) of
three-phase motors
at 50 Hz and
500 V
230 V
400 V
500 V
690 V
690 V
kW
kW
kW
kW
Rated control
DT Screw terminals
supply voltage
Us
OperaVersion
tional
current Ie
up to
NO
Article No.
NC
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
V AC/DC
S6
S10
S12
115
37
55
75
110
160
96 127
200 277
B
B
3RT1054-1PF35
3RT1054-1PP35
1
1
1 unit
1 unit
41B
41B
150
45
75
90
132
185
96 127
200 277
B
B
3RT1055-6PF35
3RT1055-6PP35
1
1
1 unit
1 unit
41B
41B
185
55
90
110
160
215
96 127
200 277
B
B
3RT1056-6PF35
3RT1056-6PP35
1
1
1 unit
1 unit
41B
41B
225
55
110
160
200
275
96 127
200 277
B
B
3RT1064-6PF35
3RT1064-6PP35
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
96 127
200 277
B
B
3RT1065-6PF35
3RT1065-6PP35
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
96 127
200 277
B
B
3RT1066-6PF35
3RT1066-6PP35
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
430
96 127
200 277
B
B
3RT1075-6PF35
3RT1075-6PP35
1
1
1 unit
1 unit
41B
41B
500
160
250
355
400
610
96 127
200 277
B
B
3RT1076-6PF35
3RT1076-6PP35
1
1
1 unit
1 unit
41B
41B
3/24
Siemens IC 10 AO 2014
Siemens AG 2014
Options
Rated control supply voltages, possible on request (the 10th and 11th position of the Article No. must be changed)
Rated control supply
voltage Us
3RT102,
3RT103,
3RT104
3RT144
3RT131,
3RT151
3RT1617,
3RT1627,
3RT1647
S00
3RT132...
3RT134,
3RT152,
3RT153
S0, S2, S3
S0, S2, S3
S3
B0
D0
H0
F0
P0
U0
V0
B0
D0
H0
F0
P0
U0
V0
B0
D0
H0
F0
P0
U0
V0
B0
D0
H0
F0
P0
U0
V0
B0
--F0
P0
U0
V0
B0
--F0
P0
U0
V0
B0
D0
H0
F0
N2
P0
P2
C2
D2
H2
G2
N2
L2
P2
C2
D2
H2
G2
N2
L2
P2
B0
D0
H0
F0
N2
P0
P2
C2
D2
H2
G2
N2
L2
P2
C2
--G2
N2
L2
P2
K6
P6
K6
P6
K6
P6
K6
P6
K6
P6
K6
P6
G6
N6
R6
G6
N6
R6
G6
N6
R6
G6
N6
R6
G6
N6
R6
G6
N6
R6
A4
B4
D4
W4
E4
F4
G4
M4
P4
-B4
D4
W4
E4
F4
G4
M4
P4
-B4
D4
W4
E4
F4
G4
M4
P4
A4
B4
D4
W4
-F4
G4
M4
P4
-B4
D4
--F4
G4
M4
--
----------
Size S00
S00, S0, S3
Sizes S2 and S3
AC operation
Solenoid coils for 50 Hz1)
24 V AC
42 V AC
48 V AC
110 V AC
230 V AC
240 V AC
400 V AC
Solenoid coils for 50 and 60 Hz1)
24 V AC
42 V AC
48 V AC
110 V AC
220 V AC
230 V AC
240 V AC
Solenoid coils (for USA and Canada2))
50 Hz
60 Hz
110 V AC
220 V AC
120 V AC
240 V AC
60 Hz4)
100 V AC
200 V AC
400 V AC
110 V AC
220 V AC
440 V AC
DC operation
12 V DC
24 V DC
42 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC
230 V DC
Examples
AC operation
3RT1034-1AP00
3RT1034-1AG20
Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage 230 V AC.
Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage 110 V AC.
DC operation
3RT1034-3BB40
3RT1034-3BG40
Contactor with spring-type terminals; for rated control supply voltage 24 V DC.
Contactor with spring-type terminals; for rated control supply voltage 125 V DC.
Rated control
supply voltage Us
3RT1.5.-.P
3RT1.6.-.P
3RT1.7.-.P
S6, S10, S12
Sizes S6 to S12
UC operation (AC 50 ... 60 Hz, DC)
Conventional operating mechanisms
23 ... 26 V AC/DC
42 ... 48 V AC/DC
110 ... 127 V AC/DC
200 ... 220 V AC/DC
220 ... 240 V AC/DC
B3
D3
F3
M3
P3
U3
V3
R3
S3
T3
1)
B3
F3
P3
-F3
P3
3)
Siemens IC 10 AO 2014
3/25
Siemens AG 2014
Overview
UC operation
The contactors can be operated with AC (50 to 60 Hz) as well as
with DC.
3/26
Siemens IC 10 AO 2014
Siemens AG 2014
3RT126.
Size
3RT127.
Rated data
Auxiliary
contacts,
AC-1,
Tu: 40 C lateral
Ratings1) of
three-phase motors
at 50 Hz and
Rated control
DT Screw terminals
supply voltage
Us
Operational
current Ie
up to
Article No.
1000 V
230 V
400 V
500 V
690 V
1000 V
kW
kW
kW
kW
NO
NC
V AC/DC
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
S10
S12
A1(+)
A2()
225
55
110
160
200
330
110 127
220 240
A
A
3RT1264-6AF36
3RT1264-6AP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
110 127
220 240
A
A
3RT1265-6AF36
3RT1265-6AP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
110 127
220 240
A
A
3RT1266-6AF36
3RT1266-6AP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
610
110 127
220 240
A
A
3RT1275-6AF36
3RT1275-6AP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
500
610
110 127
220 240
A
A
3RT1276-6AF36
3RT1276-6AP36
1
1
1 unit
1 unit
41B
41B
S10
S12
A1(+)
A2()
225
55
110
160
200
330
96 127
200 277
B
B
3RT1264-6NF36
3RT1264-6NP36
1
1
1 unit
1 unit
41B
41B
265
75
132
160
250
330
96 127
200 277
B
B
3RT1265-6NF36
3RT1265-6NP36
1
1
1 unit
1 unit
41B
41B
300
90
160
200
250
330
96 127
200 277
B
B
3RT1266-6NF36
3RT1266-6NP36
1
1
1 unit
1 unit
41B
41B
400
132
200
250
400
610
96 127
200 277
B
B
3RT1275-6NF36
3RT1275-6NP36
1
1
1 unit
1 unit
41B
41B
500
160
250
355
500
610
96 127
200 277
B
B
3RT1276-6NF36
3RT1276-6NP36
1
1
1 unit
1 unit
41B
41B
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be switched must be considered
when selecting the units.
Siemens IC 10 AO 2014
3/27
Siemens AG 2014
Overview
Snap-on auxiliary switch blocks
Various auxiliary switch blocks can be added to the 3RT1 basic
units depending on the application:
Size S00
Size S00 contactors have an auxiliary contact integrated in the
basic unit.
Contactors, EN 50012,
1 aux. contact
Ident. No. 01
Contactors,
EN 50012
5, 4 or 2
aux. contacts
Contactors,
EN 50005,
5 or 3
aux. contacts
Also available are 2-pole auxiliary switch blocks (screw terminals) for cable entry from above or below in the design of a quad
block (feeder auxiliary switch).
If the installation space is limited in depth, 2-pole auxiliary switch
blocks (screw or spring-type connections) can be attached laterally (on the left or on the right).
Contactors
3RT102.
3RT103.
3RT104.
without
aux. contact
1 NO
1 NC
Possible complements of
contactors with 1-pole
aux. switch blocks,
terminal signations
acc. to EN 50005 or
EN 50012
Ident. No.
01, 10
11
21, 12
31, 22, 13
02, 20
03, 30
04, 40
NSB0_00451c
Ident. No. 10
NSB0_00450d
The Ident. Nos. on the auxiliary switch blocks apply only to the
attached auxiliary switches.
Single- or 2-pole auxiliary switch blocks with only one connection option from above or below are provided for easy and
clearly arranged wiring especially for the installation of network
access junctions. These auxiliary switch blocks are offered only
with screw terminals.
3/28
Siemens IC 10 AO 2014
Siemens AG 2014
The 3RH1 contactor relays can be expanded by up to four contacts by the addition of snap-on auxiliary switch blocks.
Contactor relay, EN 50 011,
4 contacts
Possible complements of
contactors with 4-pole
aux. switch blocks,
terminal designations
acc. to EN 50005
Possible complements of
contactors with 4-pole
aux. switch blocks,
terminal designations
acc. to EN 50012
NSB0_00452c
Contactor relay,
EN 50 011
8 contacts
Contactor
relay,
Hilfsschtze
EN
005,
DIN50EN50005,
88oroder
6 contacts
6 Kontakte
The auxiliary switch blocks attached to the front can be disassembled with the help of a centrally arranged release lever; the
laterally attached auxiliary switch blocks are easy to remove by
pressing on the checkered surfaces.
The laterally mountable auxiliary switch blocks according to
EN 50012 can be used only when no 4-pole auxiliary switch
blocks are snapped onto the front. If single-pole auxiliary switch
blocks are used in addition, the location identifiers on the
contactor must be noted.
Two enclosed and two standard contacts are available with the
3RH1921-.FE22 solid-state compatible auxiliary switch block,
which can be attached to the front. The laterally mountable,
solid-state compatible 3RH1921-2DE11 auxiliary switch block
contains two enclosed contacts (1 NO + 1 NC). The enclosed
contacts are suitable in particular for switching small voltages
and currents (hard gold-plated contacts) and for operation in
dusty atmospheres. The NC auxiliary contacts are mirror
contacts.
Sizes S0 and S2
A maximum of 4 auxiliary contacts can be attached; the auxiliary
switch blocks used can be of any version. For reasons of symmetry, when two 2-pole laterally mountable auxiliary switch
blocks are used, one block must be attached on the right and
one on the left.
More auxiliary contacts are permissible with size S2 under
certain conditions (please ask).
NSB0_00067c
Siemens IC 10 AO 2014
3/29
3RT102.
3RT103.
3RT104.
contactors
without
aux. contact
Siemens AG 2014
A1/A2
NSB0_00938
Y -7/-8
-7/-8
t
50 ms
NSB0_00454b
b) OFF-delay
NSB0_00455b
L1
K3
S1
A1 B1 A2
K3
S1
A1 B1 A2
K3
1
2
A1
A1
A2
N
Timing relay block
2 Contactor
A2
2
N
The activation of loads parallel to the start input is not permissible when using AC control voltage (see (a) in the circuit
diagram).
The 3RT1926-2D. . . OFF-delay timing relay blocks have a zero
potential start input B1. This means that if there is a parallel load
on terminal B1, activation can be simulated with AC voltage. In
this case, the additional load (e. g. contactor K3) must be wired
(see (b) in the circuit diagram).
3/30
Siemens IC 10 AO 2014
Siemens AG 2014
AC and DC operation
The module is available for size S00 and is plugged onto the
front of the contactors with and without auxiliary switch block.
For screw and snap-on mounting onto 35 mm standard mounting rail. The OFF-delay devices have screw terminals.
A contactor opens after a delay when the capacitors of the solenoid coil, built into the OFF-delay device, are switched in parallel. In the event of voltage failures, the capacitors are discharged
via the solenoid coil and thereby delay the opening of the contactor.
DC operation
The coupling link is suitable for use in any climate. It is fingersafe according to EN 50274. The terminal designations comply
with EN 50005.
System-compatible operation with 24 V DC,
operating range 17 to 30 V.
Surge suppression
Mounting
The 3RH1924-1GP11 coupling link is mounted directly on the
contactor coil.
Solder pin adapters
The solder pin adapters for the size S00 contactors are available
in two versions:
Solder pin adapters for contactors with one integrated
auxiliary contact
Solder pin adapters for contactors with mounted 4-pole
auxiliary switch block
Screw adapters
Plug-on adapters improve the accessibility of the screw connection for size S0 contactors. As a result it is possible to position
the screwdriver vertically even when using insulated screwdrivers or power screwdrivers.
Optionally the adapters can be rotated through 90 before
mounting.
Sealable covers for sizes S2 to S12
When contactors and contactor relays are used in safetyoriented applications, it must be ensured that it is impossible to
operate the contactors manually.
For SIRIUS contactors there are sealable covers available for
this purpose as accessories; these prevent accidental manual
operation. These are transparent molded-plastic caps with a
bracket that enables the contactor to be sealed.
The surge suppressors are plugged onto the front of size S00
contactors. Space is provided for them next to a snap-on auxiliary switch block.
With all size S0 to S3 contactors, varistors, RC elements and
diode assemblies can be plugged on directly at the coil terminals, either on the top or underneath.
The plug-in direction of the diodes and diode assemblies is
determined by a coding device.
Coupling contactors are supplied either without overvoltage
damping or with a varistor or diode connected as standard,
according to the version.
Note:
The OFF-delay of the NO contact and the ON-delay of the
NC contact are increased if the contactor coils are attenuated
against voltage peaks (noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).
Siemens IC 10 AO 2014
3/31
Siemens AG 2014
NSB0_00457c
What is known as a counter-e.m.f. (electromotive force) is produced when motors or various inductive loads are turned off.
Voltage peaks of up to 4000 V may occur as a result, with a frequency spectrum from 1 kHz to 10 MHz and a rate of voltage
variation from 0.1 to 20 V/ns.
930 V
400 V
t
500 ms
The varistor circuit can absorb a high energy level and can
also be used for frequencies ranging from 10 to 400 Hz
(closed-loop controlled operating mechanisms). There is no
limiting below the knee-point voltage, however.
NSB0_00458c
NSB0_00456c
400 V
500 ms
3/32
Siemens IC 10 AO 2014
950 V
400 V
500 ms
Siemens AG 2014
Circuit diagrams
Function
Function chart
Circuit diagrams
3RT1916-2E
3RT1926-2E
S1
6
A1
A1
A2
A2
3RT1916-2E, 3RT1926-2E
1 NO + 1 NC
NSB0_00933
With ON-delay
27
35
$
28
36
$
A1
A2
3RT1916-2F, 3RT1926-2F
1 NO + 1 NC
A1/A2
3RT1916-2F
28
36
3RT1926-2F
> 200 ms
35/36
6
S1
NSB0_00934
27/28
A1
A1
A2
A2
27
35
$
28
36
$
A1
A2
27
35
28
36
NSB0_01874a
NSB0_01839
3RT1916-2L
NSB0_00859
OFF-delay,
with auxiliary voltage
35
NSB0_01873
NSB0_01838
OFF-delay
without auxiliary voltage
27
A1/A2
>35 ms
1 CO contact
B1/A2
S1
A1
B1
15/18
15/16
A2
15
A1
16 18
A2
NSB0_01841
3RT1916-2G, 3RT1926-2G
1 NO delayed,
1 NO instantaneous,
dead time 50 ms
A1/A2
3RT1916-2G
NSB0_00935
Wye-delta function
Y 27/28
37/38
t
3RT1926-2G
6
S1
A1
A1
50 ms
A2
A2
27
37
$
28
38
$
A1
A2
NSB0_01840a
27
37
28
38
NSB0_01875
t
A1/A2
Contactor
A1
1
A1
A2
A1
A2
N/L
A1/A2
Contactor
A1
A2
A1
A2
A1
A2
To be connected
optionally
1 Timing relay block
2 Contactor
L1/L+
NSB0_0940a
3RT1916-2D, 3RT1926-2D
A2 can be connected
to N(L-) using either
the contactor or the
timing relay.
N/L-
A1/A2
Timing relay
B1/A2
> 35 ms
A1/A2
Contactor
2 Contactor
L1/L+
A1/A2
Timing relay
t
OFF-delay,
with auxiliary voltage
NSB0_00556
3RT1926-2C
NSB0_0939a
ON-delay,
two-wire version
NSB0_00943b
A1/A2
Timing relay
A2 must only be
connected to N(L--)
from the timing relay.
S1
A1 B1
A2
1
A1
A2
A1
A2
N/L
NSB0_00557
3RT1916-2C
NSB0_0939a
ON-delay,
two-wire version
Do not connect
1
2 Contactor
Siemens IC 10 AO 2014
3/33
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RH1911-1HA. .
3RH1911-2HA. .
Type
3RH1921-1HA. .
Version
NO
3RH1921-2HA. .
DT Screw terminals
NC
Article No.
NO
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
01 11
--
--
--
21
12 22
--
--
21 31 43
13 23
--
--
22 32
--
--
3RH1911-1HA01
3RH1911-2HA01
3RH1911-1HA12
3RH1911-2HA12
3RH1911-1HA13
3RH1911-2HA13
3RH1911-1HA22
3RH1911-2HA22
3RH1921-1HA31
3RH1921-2HA31
3RH1921-1HA22
3RH1921-2HA22
3RH1921-1HA13
3RH1921-2HA13
3RH1921-1XA22-0MA0
3RH1921-2XA22-0MA0
22
22 32 44
21 31 41 53
22 32 42 54
21 31 43 53
22 32 44 54
Sizes S0 to S31)
4-pole auxiliary switch blocks
3RT1.2,
3RT1.3,
3RT1.4
31
--
--
22
--
--
13
--
--
13 21 33 43
14 22 34 44
13 21 31 43
14 22 32 44
13 21 31 41
14 22 32 42
Sizes S0 to
S122)
4-pole auxiliary switch blocks
3RT1.3 ...
3RT1.7
22
--
--
53 61 71 83
54 62 72 84
3/34
Siemens IC 10 AO 2014
1)
2)
Exception: 3RT16.
Exception: 3RT12, 3RT16.
Siemens AG 2014
Ident. No.
Type
3RH1911-1FA. .
Version
NO
3RH1911-2FA. .
DT Screw terminals
NC
Article No.
NO
3RH1911-1LA..
For contactors Auxiliary contacts
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
3RH1911-1FA20
3RH1911-2FA20
3RH1911-1FA11
3RH1911-2FA11
3RH1911-1FA02
3RH1911-2FA02
3RH1911-1FB11
3RH1911-2FB11
3RH1911-1FA40
3RH1911-2FA40
53 61 73 83
3RH1911-1FA31
3RH1911-2FA31
--
54 62 74 84
57 67 75 85
3RH1911-1FA22
3RH1911-2FA22
57 67 75 85
3RH1911-1FC22
3RH1911-2FC22
3RH1911-1FB22
3RH1911-2FB22
20
--
--
11
--
--
53 61
02
--
--
--
54 62
51 61
11U
--
--
40
--
--
--
53 63 73 83
31
--
--
22
--
22U
--
--
11, 11U
53 63
54 64
52 62
57 65
58 66
54 64 74 84
58 68 76 86
58 68 76 86
53 61 75 87
54 62 76 88
--
--
--
--
--
--
51
--
53 61
--
54 62
53 63
51
3RH1911-1AA10
--
3RH1911-1AA01
--
3RH1911-1LA11
--
3RH1911-1LA20
--
52
52
54 64
Siemens IC 10 AO 2014
3/35
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RH1921-1FA. .
For contactors Auxiliary contacts
Ident. No.
Type
Version
NO
3RH1921-2FA. .
DT Screw terminals
NC
Article No.
NO
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
--
--
--
--
--
--
51
--
53 61
--
54 62
53 63
51
3RH1911-1BA10
--
3RH1911-1BA01
--
3RH1911-1MA11
--
3RH1911-1MA20
--
3RH1921-1FA40
3RH1921-2FA40
3RH1921-1FA31
3RH1921-2FA31
3RH1921-1FA22
3RH1921-2FA22
3RH1921-1FA04
3RH1921-2FA04
3RH1921-1FC22
3RH1921-2FC22
52
52
54 64
Sizes S0 to S31)
4-pole auxiliary switch blocks
3RT1.3,
3RT1.4
40
--
--
--
31
--
--
22
--
--
13 23 31 41
04
--
--
--
11 21 31 41
22 U
--
--
13 23 33 43
14 24 34 44
13 23 33 41
14 24 34 42
14 24 32 42
12 22 32 42
17 27 35 45
18 28 36 46
3/36
Siemens IC 10 AO 2014
1)
Exception: 3RT16.
Siemens AG 2014
3RH1921-1MA. .
3RH1921-1C. .
Ident. No.
Type
Version
NO
3RH1921-2C. .
DT Screw terminals
NC
Article No.
NO
3RH1921-1LA. .
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
11
--
--
13 21
20
--
--
--
13 23
02
--
--
--
11 21
3RH1921-1LA11
--
3RH1921-1LA20
--
3RH1921-1LA02
--
3RH1921-1MA11
--
3RH1921-1MA20
--
3RH1921-1MA02
--
3RH1921-1CA10
3RH1921-2CA10
3RH1921-1CA01
3RH1921-2CA01
3RH1921-1CD10
--
3RH1921-1CD01
--
14 22
14 24
12 22
11
--
--
13 21
20
--
--
--
13 23
02
--
--
--
11 21
14 22
14 24
12 22
Sizes S0 to S122)
1-pole auxiliary switch blocks
according to EN 50005 and EN 50012
3RT1.3 ...
3RT1.7
10
--
--
--
.3
01
--
--
--
.1
10
--
--
--
.7
01
--
--
--
.5
.4
.2
.8
.6
1)
2)
Exception: 3RT16.
Exception: 3RT12, 3RT16
Siemens IC 10 AO 2014
3/37
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RH1921-1.A11
For contactors Auxiliary contacts
DT Screw terminals
Version
Type
NO
3RH1921-2.A11
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
Right
21 13
22 14
Mounting:
Left
31 43
3RH1921-1DA11
3RH1921-2DA11
3RH1921-1JA11
3RH1921-2JA11
3RH1921-1EA20
3RH1921-2EA20
3RH1921-1EA11
3RH1921-1EA02
3RH1921-2EA02
3RH1921-1KA20
3RH1921-2KA20
3RH1921-1KA11
3RH1921-1KA02
32 44
Right
61 53
71 83
62 54
72 84
Right
--
53 63
73 83
54 64
74 84
51 63
71 83
52 64
72 84
--
51 61
71 81
52 62
72 82
Mounting:
Sizes S3 to S12
Left
--
Right
3/38
--
153 163
154 164
174 184
151 163
171 183
152 164
172 184
--
151 161
171 181
152 162
172 182
Siemens IC 10 AO 2014
173 183
--
3RH1921-2KA02
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RH1921-2DE11,
3RH1921-2JE11
For contactors
3RH1911-1NF. .
3RH1921-1FE22
Contacts
DT Screw terminals
Version
Type
NO
3RH1921-2FE22
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NO1) NC1) NC
--
--
--
--
--
--
--
--
53 61
3RH1911-1NF11
3RH1911-2NF11
3RH1911-1NF20
3RH1911-2NF20
3RH1911-1NF02
3RH1911-2NF02
3RH1921-1FE22
3RH1921-2FE22
--
3RH1921-2DE11
--
3RH1921-2JE11
54 62
53 63
54 64
51 61
52 62
Sizes S0 to S3
3RT1.3 ...
3RT1.7
13 23 31 41
14 24 32 42
Sizes S0 to S12
Right
--
--
21 13
22 14
Left
Sizes S3 to S12
31 43
32 44
Right
1)
--
--
61 53
71 83
62 54
72 84
Siemens IC 10 AO 2014
3/39
Siemens AG 2014
Auxiliary contacts
Time setting
range t
DT Screw terminals
Article No.
Type
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
Solid-state time-delay auxiliary switch blocks for snapping onto the front,
terminal designations according to DIN 46199-5
Size S00
With ON-delay3)
3RT1.1,
3RH112)
3RH14
1 NO + 1 NC
24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1916-2EJ11
3RT1916-2EJ21
3RT1916-2EJ31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
B
B
3RT1916-2EC11
3RT1916-2EC21
3RT1916-2EC31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1916-2ED11
3RT1916-2ED21
3RT1916-2ED31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
}
3RT1916-2FJ11
3RT1916-2FJ21
3RT1916-2FJ31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1916-2FK11
3RT1916-2FK21
3RT1916-2FK31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
}
3RT1916-2FL11
3RT1916-2FL21
3RT1916-2FL31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
B
B
B
3RT1916-2LJ21
3RT1916-2LC21
3RT1916-2LD21
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
3RT1916-2. . . .
OFF-delay without auxiliary voltage3)4)
3RT1.1,
3RH112)
3RH14
1 NO + 1 NC
1 CO
3RT1012)
1 NO delayed +
1 NO instantaneous,
dead time 50 ms
24 AC/DC
100 ... 127 AC
200 ... 240 AC
0.5 ... 10
0.5 ... 10
0.5 ... 10
1.5 ... 30
1.5 ... 30
1.5 ... 30
}
B
B
3RT1916-2GJ51
3RT1916-2GC51
3RT1916-2GD51
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
C
}
A
3RT1926-2EJ11
3RT1926-2EJ21
3RT1926-2EJ31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
C
}
C
3RT1926-2EC11
3RT1926-2EC21
3RT1926-2EC31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1926-2ED11
3RT1926-2ED21
3RT1926-2ED31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
24 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
}
}
}
3RT1926-2FJ11
3RT1926-2FJ21
3RT1926-2FJ31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1926-2FK11
3RT1926-2FK21
3RT1926-2FK31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
A
A
3RT1926-2FL11
3RT1926-2FL21
3RT1926-2FL31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
Sizes S0 to S12
With ON-delay5)
3RT10,
3RT13,
3RT14,
3RT15
1 NO + 1 NC
3RT1926-2. . . .
1 NO + 1 NC
1 NO delayed +
1 NO instantaneous,
dead time 50 ms
24 AC/DC
1.5 ... 30
3RT1926-2GJ51
1 unit
41H
1.5 ... 30
3RT1926-2GC51
1 unit
41H
1.5 ... 30
3RT1926-2GD51
1 unit
41H
3/40
Siemens IC 10 AO 2014
5)
Terminals A1 and A2 for the control supply voltage of the solid-state timedelay auxiliary switch must be connected to the associated contactor by
means of connecting cables.
Siemens AG 2014
DT Screw terminals
Article No.
Type
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
3RT1.1,
3RH111)
3RH14
3RT1916-2C. . .
0.05 ... 1
0.5 ... 10
5 ... 100
B
}
B
3RT1916-2CG11
3RT1916-2CG21
3RT1916-2CG31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
A
}
A
3RT1916-2CH11
3RT1916-2CH21
3RT1916-2CH31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
3RT1916-2D. . .
3RT1.1,
3RH111)
3RH14
24 ... 66 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
B
B
B
3RT1916-2DG11
3RT1916-2DG21
3RT1916-2DG31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
B
B
3RT1916-2DH11
3RT1916-2DH21
3RT1916-2DH31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
Sizes S0 to S3
For mounting onto top-lying coil terminals,
(only for contactors with screw terminals)
ON-delay (varistor integrated)
3RT102,
3RT103,
3RT1042),
3RT13,
3RT15
24 ... 66 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
B
B
B
3RT1926-2CG11
3RT1926-2CG21
3RT1926-2CG31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
}
}
}
3RT1926-2CH11
3RT1926-2CH21
3RT1926-2CH31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
3RT1926-2C. . .
24 ... 66 AC/DC
0.05 ... 1
0.5 ... 10
5 ... 100
C
B
D
3RT1926-2DG11
3RT1926-2DG21
3RT1926-2DG31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
0.05 ... 1
0.5 ... 10
5 ... 100
B
B
C
3RT1926-2DH11
3RT1926-2DH21
3RT1926-2DH31
1
1
1
1 unit
1 unit
1 unit
41H
41H
41H
110 AC/DC
3RT1916-2BK01
1 unit
41H
3RT1.1,
220/230 AC/DC
3RT1.2,
3RH1. . .-1BM40
3RT1916-2BL01
1 unit
41H
3RT1.1,
3RT1.2,
3RT1.3,
3RT1.4,
3RH1. . .-1BB40
3RT1916-2BE01
1 unit
41H
0.1 ... 30
1 ... 60
C
C
3RT1926-2PA01
3RT1926-2PA11
1
1
1 unit
1 unit
41B
41B
0.1 ... 30
1 ... 60
C
C
3RT1926-2PR01
3RT1926-2PR11
1
1
1 unit
1 unit
41B
41B
3RT1926-2D. . .
OFF-delay devices
Sizes S00 to S3
3RT1.1,
3RT1.2,
3RH1. . .-1BF40
3RT1916-2B.01
24 DC
3RT1926-2P. . .
OFF-delay
3)
4)
Siemens IC 10 AO 2014
3/41
Siemens AG 2014
Version
Type
Power
DT Article No.2)
consumption
AC operation DC operation of LED
at Us
Rated control supply
voltage Us1)
V AC
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
V DC
24 ... 48
48 ... 127
127 ... 240
--
12 ... 24
24 ... 70
70 ... 150
150 ... 250
10 ... 120
20 ... 470
50 ... 700
160 ... 950
}
}
}
A
3RT1916-1JJ00
3RT1916-1JK00
3RT1916-1JL00
3RT1916-1JP00
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
----
24 ... 70
50 ... 150
150 ... 250
20 ... 470
50 ... 700
160 ... 950
}
}
}
3RT1916-1LM00
3RT1916-1LN00
3RT1916-1LP00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
PU
(UNIT,
SET,
M)
PS*
PG
3RT1916-1L.00
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 or 5 units, "-Z" and order code "X90" must be added to the
Article No.
For
contactors
Version
DT Article No.2)
Price
per PU
AC operation DC operation
Type
V AC
V DC
Varistor
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
A
}
A
3RT1916-1BB00
3RT1916-1BC00
3RT1916-1BD00
3RT1916-1BE00
3RT1916-1BF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RT1.,
3RH1
RC elements
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
}
}
}
3RT1916-1CB00
3RT1916-1CC00
3RT1916-1CD00
3RT1916-1CE00
3RT1916-1CF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RT1.,
3RH1
12 ... 250
3RT1916-1DG00
1 unit
41B
3RT1.,
3RH1
Diode assemblies
(diode and Zener diode) for
DC operation
--
12 ... 250
3RT1916-1EH00
1 unit
41B
3RT1916-1DG00
Size S0
For fitting onto the coil terminals
at top or bottom
3RT1.2
Varistor
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
}
}
B
3RT1926-1BB00
3RT1926-1BC00
3RT1926-1BD00
3RT1926-1BE00
3RT1926-1BF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RT1.2
RC elements
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
}
}
B
3RT1926-1CB00
3RT1926-1CC00
3RT1926-1CD00
3RT1926-1CE00
3RT1926-1CF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RT1.2
Diode assembly
for DC operation
---
24
30 ... 250
}
}
3RT1926-1ER00
3RT1926-1ES00
1
1
1 unit
1 unit
41B
41B
24
30 ... 250
}
A
3RT1926-1TR00
3RT1926-1TS00
1
1
1 unit
1 unit
41B
41B
3RT1926-1B.00
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 units, "-Z" and order code "X90" must be added to the
Article No.
3/42
Siemens IC 10 AO 2014
Siemens AG 2014
Version
DT Article No.2)
Price
per PU
AC operation DC operation
Type
V AC
PU
(UNIT,
SET,
M)
PS*
PG
V DC
24 ... 70
70 ... 150
150 ... 250
--
}
}
}
}
B
3RT1926-1BB00
3RT1926-1BC00
3RT1926-1BD00
3RT1926-1BE00
3RT1926-1BF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
}
}
B
3RT1936-1CB00
3RT1936-1CC00
3RT1936-1CD00
3RT1936-1CE00
3RT1936-1CF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
---
24
30 ... 250
}
}
3RT1936-1ER00
3RT1936-1ES00
1
1
1 unit
1 unit
41B
41B
24
30 ... 250
}
B
3RT1936-1TR00
3RT1936-1TS00
1
1
1 unit
1 unit
41B
41B
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RT1956-1CB02
3RT1956-1CC02
3RT1956-1CD02
3RT1956-1CE02
3RT1956-1CF02
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
DT Screw terminals
PU
(UNIT,
SET,
M)
PS*
PG
3RT1.3,
3RT1.4
Varistor
3RT1.33),
3RT1.4
RC elements
3RT1.3,
3RT1.4
3RT1926-1B.00
3RT1936-1C.00
3RT1.5,
3RT1.6,
3RT1.7
RC elements
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
--
Screw terminals
}
}
}
}
C
3RT1956-1CB00
3RT1956-1CC00
3RT1956-1CD00
3RT1956-1CE00
3RT1956-1CF00
Spring-type
terminals
3RT1.5,
3RT1.6,
3RT1.7
RC elements
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
--
}
A
}
A
C
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 or 5 units, "-Z" and order code "X90" must be added to the
Article No.
3) For 3RT1. 3 with AC operation mountable only at the top.
For
contactors
Version
Article No.
Type
Price
per PU
Main current path surge suppression modules for 3RT12 vacuum contactors
Size S10 and S12
3RT12
3RT1966-1PV3
1 unit
41B
3RT1966-1PV4
1 unit
41B
Siemens IC 10 AO 2014
3/43
Siemens AG 2014
DT Screw terminals
Article No.
Type
PU
(UNIT,
SET,
M)
PS*
PG
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
24 AC/DC
110 AC/DC
230 AC/DC
A
B
B
3RT1926-3AB31
3RT1926-3AF31
3RT1926-3AP31
DT Article No.
Price
per PU
Type
3RT1916-1PA1
3RT1916-1PA2
3RT1916-1PA3
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
A
B
D
3RT1916-1PB1
3RT1916-1PB2
3RT1916-1PB3
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3RT1916-1GA00
1 unit
41B
3RK1 903-0CA00
1 unit
42D
Up to 400 V
Up to 575 V
Up to 690 V
3RT101
Varistor
Up to 400 V
Up to 575 V
Up to 690 V
3RT1916-1PA.
3RT1916-1GA00
Control kit
Size S00
3RT1.1,
3RH1.
3RK1 903-0CA00
1)
2)
3/44
Siemens IC 10 AO 2014
Siemens AG 2014
DT Screw terminals
Article No.
Type
PU
(UNIT,
SET,
M)
PS*
PG
1 unit
41B
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
3RT1.2,
3RT1.3,
3RT1.4
3RH1924-1GP11
3RH1924-1GP11
B2- N
1
A1
A2
Coupling link
Contactor
NSB0_00182a
For
contactors
Version
DT Article No.
Price
per PU
Type
3RT1926-1QT00
5 units
41B
3RT1946-4F
1 unit
41B
3RT1926-1QT00
mounted to contactor
3RT1946-4F
1)
Siemens IC 10 AO 2014
3/45
Siemens AG 2014
Size
Version
DT Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
Type
S6
3RT1.5
(3RB20 5)
S10, S12
3RT195.-4G
3RT1.6,
3RT1.7
(3RB206,
3RB216)
Up to 70 mm 2)
Up to 120 mm
}
}
3RT1955-4G
3RT1956-4G
1
1
1 unit
1 unit
41B
41B
3TX7500-0A
1 unit
41B
Up to 240 mm
3RT1966-4G
1 unit
41B
Covers
Terminal covers for box terminals
(additional touch protection)
To be fitted at the box terminals
(2 units required per contactor)
3RT1936-4EA2
3RT1956-4EA2
3RT103
--
3RT1936-4EA2
1 unit
41B
3RT133,
3RT153
3RT1936-4EA4
1 unit
41B
S3
3RT104,
3RT144
--
3RT1946-4EA2
1 unit
41B
3RT134
3RT1946-4EA4
1 unit
41B
S63)
3RT1.5
Length: 25 mm
3RT1956-4EA2
1 unit
41B
Length: 30 mm
3RT1966-4EA2
1 unit
41B
--
3RT1946-4EA1
1 unit
41B
S2
3RT1956-4EA1
S3
3RT104,
3RT144
S6
3RT1.5
Length: 100 mm
3RT1956-4EA1
1 unit
41B
S10/S12
3RT1.6,
3RT1.7
Length: 120 mm
3RT1966-4EA1
1 unit
41B
3RT1.5
M8
3TX6526-3B
1 unit
41B
S10, S12
3RT1.6,
3RT1.7
M10
3TX6546-3B
1 unit
41B
3TX6526-3B
3RT1.5
Length: 27 mm
3RT1956-4EA3
1 unit
41B
S10/S124)
3RT1.6,
3RT1.7
Length: 42 mm
3RT1966-4EA3
1 unit
41B
3RT1.5
Length: 38 mm
3RT1956-4EA4
1 unit
41B
S00
3RT1.1...
3RH1. 5)
Sealable covers
for preventing manual operation
3RT1916-4MA10
5 units
41B
S0 ... S12
3RT1.3 ...
3RT1.75)
3RT1926-4MA10
5 units
41B
Sealable covers
NSB0_01471
3RT19.6-4MA10
1)
3/46
Siemens IC 10 AO 2014
Siemens AG 2014
DT Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
Type
3RT1926-4RD01
Screw terminals
3RT1916-4RD01
1 unit
41B
Size S0,
rated operational current Ie
at AC-3/400 V: 25 A
3RT1926-4RD01
1 unit
41B
3RT1900-4RE01
1 unit
41B
3RT1916-4KA1
4 units
41B
3RT1916-4KA2
4 units
41B
3RT1926-4P
1 10 units
41B
3RT1900-4RE01
3RT1916-4KA1
3RT1916-4KA2
NSB0_01470
3RT1926-4P
Siemens IC 10 AO 2014
3/47
3RT1 .1,
3RT1.2,
3RH1.
Siemens AG 2014
Size
mm2
DT Screw terminals
Article No.
Type
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
3RT101
25
3RT1916-4BB31
1 unit
41B
S0
3RT102
35, stranded
3RT1926-4BB31
1 unit
41B
S2
3RT103
95
3RT1936-4BB31
1 unit
41B
185
3RT1946-4BB31
1 unit
41B
3RT1936-4BB31
3-pole, with through hole
(star jumpers)1)2)
3RT1956-4BA31
S3
3RT104,
3RT144
S6
3RT1.5
--
3RT1956-4BA31
1 unit
41B
S10/S12
3RT1.6,
3RT1.7
--
3RT1966-4BA31
1 unit
41B
S00
3RT101
3RT1916-4BB41
1 unit
41B
3RT1916-4BB41
1)
2)
DT Spring-type
terminals
PU
(UNIT,
SET,
M)
PS*
PG
3RT1916-4JA02
20 units
41B
3RA2908-1A
1 unit
41B
Article No.
Price
per PU
Version
DT Article No.
Price
PU
per PU (UNIT,
SET,
M)
PS*
PG
Blank labels
NSB0_01429b
3RT1900-1SB20
3RT1900-1SB10
100
816 units
41B
3RT1900-1SB20
100
340 units
41B
3RT1900-1SB60
41B
19 mm 6 mm, zinc/yellow
3RT1900-1SD60
41B
PC labeling systems
For individual inscription of unit labeling plates available from:
Murrplastik Systemtechnik GmbH
(see Catalog IC 10, Chapter 16, "Appendix" "External Partners")
3/48
Siemens IC 10 AO 2014
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT1934-5A.01
For contactors
50/60 Hz
60 Hz
Size
24
42
48
110
-----
-----
}
B
A
}
3RT1924-5AB01
3RT1924-5AD01
3RT1924-5AH01
3RT1924-5AF01
B
C
B
B
3RT1924-5AB02
3RT1924-5AD02
3RT1924-5AH02
3RT1924-5AF02
230
400
---
---
}
}
3RT1924-5AP01
3RT1924-5AV01
B
C
3RT1924-5AP02
3RT1924-5AV02
-----
24
42
48
110
-----
}
B
B
}
3RT1924-5AC21
3RT1924-5AD21
3RT1924-5AH21
3RT1924-5AG21
B
C
C
B
3RT1924-5AC22
3RT1924-5AD22
3RT1924-5AH22
3RT1924-5AG22
---
220
230
---
B
B
3RT1924-5AN21
3RT1924-5AL21
B
B
3RT1924-5AN22
3RT1924-5AL22
110
220
---
--100
200
120
240
110
220
B
B
B
B
3RT1924-5AK61
3RT1924-5AP61
3RT1924-5AG61
3RT1924-5AN61
B
C
C
C
3RT1924-5AK62
3RT1924-5AP62
3RT1924-5AG62
3RT1924-5AN62
Type
DT Screw terminals
Article No.
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
S2
3RT102.,
3RT132.,
3RT152.
3RT1034
3RT1035,
3RT1036,
3RT133.,
3RT15 3.
--
400
440
3RT1924-5AR61
3RT1924-5AR62
24
42
48
110
-----
-----
B
B
B
B
3RT1934-5AB01
3RT1934-5AD01
3RT1934-5AH01
3RT1934-5AF01
B
B
B
B
3RT1934-5AB02
3RT1934-5AD02
3RT1934-5AH02
3RT1934-5AF02
230
400
---
---
B
C
3RT1934-5AP01
3RT1934-5AV01
B
B
3RT1934-5AP02
3RT1934-5AV02
-----
24
42
48
110
-----
B
B
B
C
3RT1934-5AC21
3RT1934-5AD21
3RT1934-5AH21
3RT1934-5AG21
B
B
B
B
3RT1934-5AC22
3RT1934-5AD22
3RT1934-5AH22
3RT1934-5AG22
---
220
230
---
C
C
3RT1934-5AN21
3RT1934-5AL21
B
B
3RT1934-5AN22
3RT1934-5AL22
110
220
---
--100
200
120
240
110
220
B
B
B
B
3RT1934-5AK61
3RT1934-5AP61
3RT1934-5AG61
3RT1934-5AN61
B
B
B
B
3RT1934-5AK62
3RT1934-5AP62
3RT1934-5AG62
3RT1934-5AN62
--
400
440
3RT1934-5AR61
3RT1934-5AR62
24
42
48
110
-----
-----
B
B
B
}
3RT1935-5AB01
3RT1935-5AD01
3RT1935-5AH01
3RT1935-5AF01
B
B
B
B
3RT1935-5AB02
3RT1935-5AD02
3RT1935-5AH02
3RT1935-5AF02
230
400
---
---
}
C
3RT1935-5AP01
3RT1935-5AV01
B
B
3RT1935-5AP02
3RT1935-5AV02
-----
24
42
48
110
-----
B
B
B
B
3RT1935-5AC21
3RT1935-5AD21
3RT1935-5AH21
3RT1935-5AG21
B
B
B
B
3RT1935-5AC22
3RT1935-5AD22
3RT1935-5AH22
3RT1935-5AG22
---
220
230
---
B
B
3RT1935-5AN21
3RT1935-5AL21
B
B
3RT1935-5AN22
3RT1935-5AL22
110
220
---
--100
200
120
240
110
220
B
B
B
B
3RT1935-5AK61
3RT1935-5AP61
3RT1935-5AG61
3RT1935-5AN61
B
B
B
B
3RT1935-5AK62
3RT1935-5AP62
3RT1935-5AG62
3RT1935-5AN62
--
400
440
3RT1935-5AR61
3RT1935-5AR62
Siemens IC 10 AO 2014
3/49
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT1944-5A.01
For contactors
3RT1945-5A.01
AC
Size
Type
3RT1945-5A.02
3RT1944-5B.42
DT Screw terminals
DC
Article No.
DT Spring-type
terminals
Price
per PU
Article No.
50 Hz
50/60 Hz
60 Hz
24
42
48
110
-----
-----
-----
B
B
B
B
3RT1944-5AB01
3RT1944-5AD01
3RT1944-5AH01
3RT1944-5AF01
B
B
B
B
3RT1944-5AB02
3RT1944-5AD02
3RT1944-5AH02
3RT1944-5AF02
230
400
---
---
---
B
B
3RT1944-5AP01
3RT1944-5AV01
B
B
3RT1944-5AP02
3RT1944-5AV02
-----
24
42
48
110
-----
-----
B
B
B
B
3RT1944-5AC21
3RT1944-5AD21
3RT1944-5AH21
3RT1944-5AG21
B
B
B
B
3RT1944-5AC22
3RT1944-5AD22
3RT1944-5AH22
3RT1944-5AG22
---
220
230
---
---
B
B
3RT1944-5AN21
3RT1944-5AL21
B
B
3RT1944-5AN22
3RT1944-5AL22
110
220
---
--100
200
120
240
110
220
-----
B
B
B
B
3RT1944-5AK61
3RT1944-5AP61
3RT1944-5AG61
3RT1944-5AN61
B
B
B
B
3RT1944-5AK62
3RT1944-5AP62
3RT1944-5AG62
3RT1944-5AN62
Price
per PU
3RT1044
3RT1045,
3RT1046,
3RT134.,
3RT1446,
3RT154.
--
400
440
--
3RT1944-5AR61
3RT1944-5AR62
24
42
48
110
-----
-----
-----
B
B
B
B
3RT1945-5AB01
3RT1945-5AD01
3RT1945-5AH01
3RT1945-5AF01
B
B
B
B
3RT1945-5AB02
3RT1945-5AD02
3RT1945-5AH02
3RT1945-5AF02
230
400
---
---
---
B
C
3RT1945-5AP01
3RT1945-5AV01
B
B
3RT1945-5AP02
3RT1945-5AV02
-----
24
42
48
110
-----
-----
B
B
B
B
3RT1945-5AC21
3RT1945-5AD21
3RT1945-5AH21
3RT1945-5AG21
B
B
B
B
3RT1945-5AC22
3RT1945-5AD22
3RT1945-5AH22
3RT1945-5AG22
---
220
230
---
---
B
B
3RT1945-5AN21
3RT1945-5AL21
B
B
3RT1945-5AN22
3RT1945-5AL22
110
220
---
--100
200
120
240
110
220
-----
B
B
B
C
3RT1945-5AK61
3RT1945-5AP61
3RT1945-5AG61
3RT1945-5AN61
B
B
B
B
3RT1945-5AK62
3RT1945-5AP62
3RT1945-5AG62
3RT1945-5AN62
--
400
440
--
3RT1945-5AR61
3RT1945-5AR62
-----
-----
-----
24
42
48
60
B
B
B
B
3RT1934-5BB41
3RT1934-5BD41
3RT1934-5BW41
3RT1934-5BE41
B
B
B
B
3RT1934-5BB42
3RT1934-5BD42
3RT1934-5BW42
3RT1934-5BE42
-----
-----
-----
110
125
220
230
B
B
B
B
3RT1934-5BF41
3RT1934-5BG41
3RT1934-5BM41
3RT1934-5BP41
B
B
B
B
3RT1934-5BF42
3RT1934-5BG42
3RT1934-5BM42
3RT1934-5BP42
-----
-----
-----
24
42
48
60
B
C
B
B
3RT1944-5BB41
3RT1944-5BD41
3RT1944-5BW41
3RT1944-5BE41
B
B
B
B
3RT1944-5BB42
3RT1944-5BD42
3RT1944-5BW42
3RT1944-5BE42
-----
-----
-----
110
125
220
230
B
B
B
B
3RT1944-5BF41
3RT1944-5BG41
3RT1944-5BM41
3RT1944-5BP41
B
B
B
B
3RT1944-5BF42
3RT1944-5BG42
3RT1944-5BM42
3RT1944-5BP42
S3
3/50
3RT103.,
3RT133.,
3RT153.
3RT104.,
3RT134.,
3RT144.,
3RT154.
Siemens IC 10 AO 2014
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT1955-5A. . .
For contactors
DT Screw terminals
Article No.
Size
Type
V AC/DC
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
Withdrawable coils
Conventional operating mechanisms
S6
S10
S10
S12
3RT105,
3RT145
3RT106,
3RT146
3RT126
vacuum
contactor
3RT107,
3RT147,
3RT127
vacuum
contactor
23 ... 26
42 ... 48
110 ... 127
200 ... 220
B
B
B
B
3RT1955-5AB31
3RT1955-5AD31
3RT1955-5AF31
3RT1955-5AM31
B
B
B
B
3RT1955-5AB32
3RT1955-5AD32
3RT1955-5AF32
3RT1955-5AM32
B
B
B
B
3RT1955-5AP31
3RT1955-5AU31
3RT1955-5AV31
3RT1955-5AR31
B
B
B
B
3RT1955-5AP32
3RT1955-5AU32
3RT1955-5AV32
3RT1955-5AR32
B
B
3RT1955-5AS31
3RT1955-5AT31
B
B
3RT1955-5AS32
3RT1955-5AT32
23 ... 26
42 ... 48
110 ... 127
200 ... 220
B
B
B
C
3RT1965-5AB31
3RT1965-5AD31
3RT1965-5AF31
3RT1965-5AM31
B
B
B
B
3RT1965-5AB32
3RT1965-5AD32
3RT1965-5AF32
3RT1965-5AM32
B
B
B
B
3RT1965-5AP31
3RT1965-5AU31
3RT1965-5AV31
3RT1965-5AR31
B
B
B
B
3RT1965-5AP32
3RT1965-5AU32
3RT1965-5AV32
3RT1965-5AR32
C
C
3RT1965-5AS31
3RT1965-5AT31
B
B
3RT1965-5AS32
3RT1965-5AT32
23 ... 26
42 ... 48
110 ... 127
200 ... 220
B
B
A
C
3RT1966-5AB31
3RT1966-5AD31
3RT1966-5AF31
3RT1966-5AM31
-----
A
C
B
C
3RT1966-5AP31
3RT1966-5AU31
3RT1966-5AV31
3RT1966-5AR31
-----
C
C
3RT1966-5AS31
3RT1966-5AT31
---
23 ... 26
42 ... 48
110 ... 127
200 ... 220
B
B
B
C
3RT1975-5AB31
3RT1975-5AD31
3RT1975-5AF31
3RT1975-5AM31
B
B
B
B
3RT1975-5AB32
3RT1975-5AD32
3RT1975-5AF32
3RT1975-5AM32
B
B
B
B
3RT1975-5AP31
3RT1975-5AU31
3RT1975-5AV31
3RT1975-5AR31
B
B
B
B
3RT1975-5AP32
3RT1975-5AU32
3RT1975-5AV32
3RT1975-5AR32
C
C
3RT1975-5AS31
3RT1975-5AT31
B
B
3RT1975-5AS32
3RT1975-5AT32
Siemens IC 10 AO 2014
3/51
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT1955-5N. . .
For contactors
DT Screw terminals
Article No.
Size
Type
V AC/DC
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
Withdrawable coils
Solid-state operating mechanism
For 24 V DC PLC output
S6
3RT105,
3RT145
21 ... 27.3
96 ... 127
200 ... 277
C
B
B
3RT1955-5NB31
3RT1955-5NF31
3RT1955-5NP31
B
B
B
3RT1955-5NB32
3RT1955-5NF32
3RT1955-5NP32
S10
3RT106,
3RT146
21 ... 27.3
96 ... 127
200 ... 277
B
B
B
3RT1965-5NB31
3RT1965-5NF31
3RT1965-5NP31
B
B
B
3RT1965-5NB32
3RT1965-5NF32
3RT1965-5NP32
3RT126
vacuum
contactor
21 ... 27.3
96 ... 127
200 ... 277
B
C
C
3RT1966-5NB31
3RT1966-5NF31
3RT1966-5NP31
3RT107,
3RT147,
3RT127
vacuum
contactor
21 ... 27.3
96 ... 127
200 ... 277
B
B
B
3RT1975-5NB31
3RT1975-5NF31
3RT1975-5NP31
S12
---B
B
B
3RT1975-5NB32
3RT1975-5NF32
3RT1975-5NP32
3RT105,
3RT145
96 ... 127
200 ... 277
B
B
3RT1955-5PF31
3RT1955-5PP31
---
S10
3RT106,
3RT146
96 ... 127
200 ... 277
B
B
3RT1965-5PF31
3RT1965-5PP31
---
S12
3RT107,
3RT147
96 ... 127
200 ... 277
B
B
3RT1975-5PF31
3RT1975-5PP31
---
3/52
Siemens IC 10 AO 2014
Siemens AG 2014
DT Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
Type
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3RT1044
3RT1045
3RT1046
}
(1 set = 3 movable and 6 fixed switching elements with fixing }
}
parts)
B
B
B
3RT1944-6A
3RT1945-6A
3RT1946-6A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S6
3RT1054
3RT1055
3RT1056
}
}
}
3RT1954-6A
3RT1955-6A
3RT1956-6A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S10
3RT1064
3RT1065
3RT1066
}
}
}
3RT1964-6A
3RT1965-6A
3RT1966-6A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S12
3RT1075
3RT1076
}
A
3RT1975-6A
3RT1976-6A
1
1
1 unit
1 unit
41B
41B
S3
3RT1446
3RT1946-6D
1 unit
41B
S6
3RT1456
3RT1956-6D
1 unit
41B
S10
3RT1466
3RT1966-6D
1 unit
41B
S12
3RT1476
3RT1976-6D
1 unit
41B
B
B
B
3RT1964-6V
3RT1965-6V
3RT1966-6V
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
B
B
3RT1975-6V
3RT1976-6V
1
1
1 unit
1 unit
41B
41B
S2
3RT1034
3RT1035
3RT1036
S3
3RT1264
3RT1265
3RT1266
S12
3RT1275
3RT1276
3RT1336
3RT1936-6E
1 unit
41B
S3
3RT1344
3RT1346
3RT1944-6E
3RT1946-6E
1
1
1 unit
1 unit
41B
41B
S2
3RT103.
3RT1936-7A
1 unit
41B
S3
3RT104.,
3RT1446
3RT1946-7A
1 unit
41B
S6
3RT1054
3RT1055
3RT1056
B
B
B
3RT1954-7A
3RT1955-7A
3RT1956-7A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S10
3RT1064
3RT1065
3RT1066
B
B
B
3RT1964-7A
3RT1965-7A
3RT1966-7A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S12
3RT1075
3RT1076
B
B
3RT1975-7A
3RT1976-7A
1
1
1 unit
1 unit
41B
41B
S6
3RT1456
3RT1956-7B
1 unit
41B
S10
3RT1466
3RT1966-7B
1 unit
41B
S12
3RT1476
3RT1976-7B
1 unit
41B
Arc chutes
Siemens IC 10 AO 2014
3/53
Size
Version
Siemens AG 2014
Coupling Contactors
SIRIUS 3RT10 coupling contactors (interface),
3-pole, 3 ... 11 kW
Overview
Two single-pole auxiliary switch blocks can be fitted to the
3RT102 coupling contactors (see Accessories on page 3/37).
DC operation
IEC 60947-1, EN 60947-1,
IEC 60947-4-1, EN 60947-4-1,
IEC 60947-5-1, EN 60947-5-1 (auxiliary switches)
3RT101.-1.B4.
Rated data
AC-2 and AC-3
Tu: Up to 60 C
Auxiliary contacts
Ident. No.
400 V
400 V
kW
Version
NO
3RT101.-2.B4.
DT Screw terminals
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
10
01
1
--
-1
}
}
3RT1015-1HB41
3RT1015-1HB42
B
B
3RT1015-2HB41
3RT1015-2HB42
10
01
1
--
-1
}
}
3RT1016-1HB41
3RT1016-1HB42
B
B
3RT1016-2HB41
3RT1016-2HB42
12
5.5
10
01
1
--
-1
A
B
3RT1017-1HB41
3RT1017-1HB42
B
B
3RT1017-2HB41
3RT1017-2HB42
10
01
1
--
-1
B
B
3RT1015-1MB41-0KT0
3RT1015-1MB42-0KT0
B
B
3RT1015-2MB41-0KT0
3RT1015-2MB42-0KT0
10
01
1
--
-1
B
B
3RT1016-1MB41-0KT0
3RT1016-1MB42-0KT0
B
B
3RT1016-2MB41-0KT0
3RT1016-2MB42-0KT0
12
5.5
10
01
1
--
-1
B
B
3RT1017-1MB41-0KT0
3RT1017-1MB42-0KT0
B
B
3RT1017-2MB41-0KT0
3RT1017-2MB42-0KT0
3/54
Siemens IC 10 AO 2014
Siemens AG 2014
Coupling Contactors
SIRIUS 3RT10 coupling contactors (interface),
3-pole, 3 ... 11 kW
DC operation
Low power consumption
Extended operating range of the solenoid coil
Integrated coil circuit
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RT101.-1.B4.
Rated data
AC-2 and AC-3
Tu: Up to 60 C
Auxiliary contacts
Ident. No.
400 V
400 V
kW
DT Screw terminals
Version
NO
3RT101.-2.B4.
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
NC
10
01
1
--
-1
}
}
3RT1015-1JB41
3RT1015-1JB42
}
}
3RT1015-2JB41
3RT1015-2JB42
10
01
1
--
-1
}
}
3RT1016-1JB41
3RT1016-1JB42
}
}
3RT1016-2JB41
3RT1016-2JB42
12
5.5
10
01
1
--
-1
}
}
3RT1017-1JB41
3RT1017-1JB42
}
A
3RT1017-2JB41
3RT1017-2JB42
10
01
1
--
-1
B
B
3RT1015-1VB41
3RT1015-1VB42
B
B
3RT1015-2VB41
3RT1015-2VB42
10
01
1
--
-1
B
B
3RT1016-1VB41
3RT1016-1VB42
B
B
3RT1016-2VB41
3RT1016-2VB42
12
5.5
10
01
1
--
-1
B
B
3RT1017-1VB41
3RT1017-1VB42
B
B
3RT1017-2VB41
3RT1017-2VB42
Siemens IC 10 AO 2014
3/55
Siemens AG 2014
Coupling Contactors
SIRIUS 3RT10 coupling contactors (interface),
3-pole, 3 ... 11 kW
DC operation
Low power consumption
Extended operating range of the solenoid coil
Integrated coil circuit
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RT101.-1.B4.
Rated data
AC-2 and AC-3
Tu: Up to 60 C
Auxiliary contacts
Ident. No.
400 V
3RT101.-2.B4.
DT Screw terminals
Version
Article No.
DT Spring-type terminals
Price
per PU
Article No.
Price
per PU
400 V
NO
kW
NC
10
01
1
--
-1
}
}
3RT1015-1KB41
3RT1015-1KB42
}
}
3RT1015-2KB41
3RT1015-2KB42
10
01
1
--
-1
}
}
3RT1016-1KB41
3RT1016-1KB42
}
}
3RT1016-2KB41
3RT1016-2KB42
12
5.5
10
01
1
--
-1
}
}
3RT1017-1KB41
3RT1017-1KB42
}
}
3RT1017-2KB41
3RT1017-2KB42
10
01
1
--
-1
A
B
3RT1015-1WB41
3RT1015-1WB42
B
B
3RT1015-2WB41
3RT1015-2WB42
10
01
1
--
-1
B
B
3RT1016-1WB41
3RT1016-1WB42
B
B
3RT1016-2WB41
3RT1016-2WB42
12
5.5
10
01
1
--
-1
B
B
3RT1017-1WB41
3RT1017-1WB42
B
B
3RT1017-2WB41
3RT1017-2WB42
3/56
Siemens IC 10 AO 2014
Siemens AG 2014
Coupling Contactors
SIRIUS 3RT10 coupling contactors (interface),
3-pole, 3 ... 11 kW
DC operation
Low power consumption
Extended operating range of the solenoid coil
Integrated coil circuit
PU (UNIT, SET, M) = 1
PS*
= 1 UNIT
PG
= 41B
3RT102.-1KB40
Rated data
AC-2 and AC-3
Tu: Up to 60 C
Auxiliary contacts
Ident. No.
400 V
400 V
kW
Version
NO
3RT102.-3KB40
DT Screw terminals
Article No.
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
NC
5.5
7.5
11
----
----
----
}
}
}
3RT1024-1KB40
3RT1025-1KB40
3RT1026-1KB40
B
}
}
3RT1024-3KB40
3RT1025-3KB40
3RT1026-3KB40
Siemens IC 10 AO 2014
3/57
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Overview
The 3RA13 reversing contactor assemblies can be ordered as
follows:
Sizes S00 to S3
Fully wired and tested, with mechanical and electrical
interlock
As individual parts for customer assembly
Complete units
The fully wired reversing contactor assemblies are suitable for
use in any climate. They are finger-safe according to EN 50274.
The contactor assemblies consist of 2 contactors with the same
power, with one NC contact in the basic unit. The contactors are
mechanically and electrically interlocked (NC contact interlock).
Sizes S6 to S12
Only as individual parts for customer assembly
Assembly kits for all sizes are available for customer assembly
of reversing contactor assemblies.
Article No.
Rating
Operational
current Ie
kW
3RT1016
5.5
12
3RT1017
5.5
12
7.5
17
3RT1025
11
25
3RT1026
15
32
18.5
40
3RT1035
22
50
3RT1036
30
65
37
80
3RT1045
45
95
3RT1046
55
115
75
150
90
185
110
225
132
265
160
300
200
400
250
500
S00
S0
S2
S3
S6
Contactor
Mechanical
Mechanical
Mechanical
Assembly kit
locking device1) locking device2) locking device3)
3RT1015
--4)
3RA1315-8XB30-1 . .
3RT1024
3RT1034
3RT1044
3RT1054
--
3RA1913-2A5)
3RA1316-8XB30-1 . .
3RA1317-8XB30-1 . .
3RA1924-1A
3RA1924-2B
--
3RA1923-2A6)
3RA1324-8XB30-1 . .
3RA1325-8XB30-1 . .
3RA1326-8XB30-1 . .
3RA1924-1A
3RA1924-2B
--
3RA1933-2A7)
3RA1334-8XB30-1...
3RA1335-8XB30-1...
3RA1336-8XB30-1...
3RA1924-1A
3RA1924-2B
--
3RA1943-2A7)
3RA1344-8XB30-1...
3RA1345-8XB30-1...
3RA1346-8XB30-1...
--
--
3RA1954-2A
3RA1953-2M8)
--
--
--
3RA1954-2A
3RA1963-2A8)
--
--
--
3RA1954-2A
3RA1973-2A8)
--
3RT1055
3RT1056
S10
3RT1064
3RT1065
3RT1066
S12
3RT1075
3RT1076
1)
2)
3)
4)
5)
6)
7)
8)
3/58
--
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Ratings of
three-phase motors
at 50 Hz and
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
Operational
current Ie
up to
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
AC operation, 50/60 Hz
7
2.2
3.5
24 AC
110 AC
230 AC
A
A
}
3RA1315-8XB30-1AB0
3RA1315-8XB30-1AF0
3RA1315-8XB30-1AP0
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
4.5
5.5
24 AC
110 AC
230 AC
A
A
}
3RA1316-8XB30-1AB0
3RA1316-8XB30-1AF0
3RA1316-8XB30-1AP0
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
12
5.5
5.5
5.5
24 AC
110 AC
230 AC
A
A
}
3RA1317-8XB30-1AB0
3RA1317-8XB30-1AF0
3RA1317-8XB30-1AP0
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3
4
3.5
4.5
4
5.5
24 DC
24 DC
}
}
3RA1315-8XB30-1BB4
3RA1316-8XB30-1BB4
1
1
1 unit
1 unit
41B
41B
3RA131.-8XB30-1. . .
DC operation
7
9
1)
2.2
3
Note:
6
1
14
14
13
14
NSB0_00459a
14
4
5
14
16
16
1)
Article No.
13
Individual parts
1
1
1
4
2
2
2
5 6
Contactor, 3 kW
Contactor, 4 kW
Contactor, 5.5 kW
Assembly kit
Article No.
Page
Q1
Q2
3RT1015
3RT1016
3RT1017
3RA1913-2A
3RT1015
3RT1016
3RT1017
3/14
3/14
3/14
3/64
4
5
6
Mechanical interlocks
2 connecting clips for 2 contactors
Wiring modules on the top and bottom for connecting
the main current paths, electrical interlock included1),
interruptible (NC contact interlock)
3RT101. contactors with one NC contact in the basic unit are required for
the electrical interlock
Siemens IC 10 AO 2014
3/59
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Fully wired and tested contactor assemblies Size S0 up to 11 kW
Rated data AC-2 and AC-3
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
Article No.
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation, 50/60 Hz
3RA132.-8XB30-1. . .
12
5.5
7.5
7.5
24 AC
110 AC
230 AC
A
A
}
3RA1324-8XB30-1AC2
3RA1324-8XB30-1AG2
3RA1324-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
17
7.5
10
11
24 AC
110 AC
230 AC
A
A
}
3RA1325-8XB30-1AC2
3RA1325-8XB30-1AG2
3RA1325-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
25
5.5
11
11
11
24 AC
110 AC
230 AC
A
A
A
3RA1326-8XB30-1AC2
3RA1326-8XB30-1AG2
3RA1326-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
5.5
7.5
11
7.5
10
11
7.5
11
11
24 DC
24 DC
24 DC
}
A
A
3RA1324-8XB30-1BB4
3RA1325-8XB30-1BB4
3RA1326-8XB30-1BB4
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
DC operation
12
17
25
1)
3
4
5.5
16
1
2
NSB0_00460b
15
14
4
12
14
Mech. interlocking,
front
Auxiliary switch block,
front
Auxiliary switch block,
lateral
Surge suppressors
The connecting
cables are
not shown.
Article No.
3RA1924-1A
3/63
3RH1921-1CA. .
3/34
3RH1921-1EA. .
3RT1926-1. . . .
3/38
3/42
Individual parts
Article No.
Page
Q1
Q2
3RT1024
3RT1025
3RT1026
1 2
1 2
1 2
Contactor, 5.5 kW
Contactor, 7.5 kW
Contactor, 11 kW
3RT1024
3RT1025
3RT1026
4
6
3RA1924-2B
3RA1923-2A
3/15
3/15
3/15
3/63
3/64
The assembly kit contains wiring modules on the top and bottom
(they also form the mechanical connection between the
contactors).
3/60
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Fully wired and tested contactor assemblies Size S2 up to 22 kW
Rated data AC-2 and AC-3
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
Article No.
230 V
400 V
500 V
690 V
kW
kW
kW
kW
PS*
PG
Price
per PU
500 V
PU
(UNIT,
SET,
M)
AC operation, 50/60 Hz
32
7.5
15
18.5
18.5
24 AC
110 AC
230 AC
A
A
A
3RA1334-8XB30-1AC2
3RA1334-8XB30-1AG2
3RA1334-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
40
11
18.5
22
22
24 AC
110 AC
230 AC
A
A
A
3RA1335-8XB30-1AC2
3RA1335-8XB30-1AG2
3RA1335-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
50
15
22
30
22
24 AC
110 AC
230 AC
B
B
A
3RA1336-8XB30-1AC2
3RA1336-8XB30-1AG2
3RA1336-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
15
18.5
22
18.5
22
30
18.5
22
22
24 DC
24 DC
24 DC
A
A
A
3RA1334-8XB30-1BB4
3RA1335-8XB30-1BB4
3RA1336-8XB30-1BB4
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
DC operation
3RA133.-8XB30-1. . .
32
40
50
1)
7.5
11
15
1
16
6
NSB0_00461b
15
14
4
12
14
Mech. interlocking,
front
Auxiliary switch block,
front
Auxiliary switch block,
lateral
Surge suppressors
Article No.
The connecting
cables are
not shown.
3RA1924-1A
3/63
3RH1921-1CA. .
3/34
3RH1921-1EA. .
3RT1926-1. . . .
3RT1936-1. . . .
3/38
3/43
Individual parts
1 2
1 2
1 2
Contactor, 15 kW
Contactor, 18.5 kW
Contactor, 22 kW
Mech. interlock,
lateral
5 6
Assembly kit
Article No.
Page
Q1
Q2
3RT1034
3RT1035
3RT1036
3RT1034
3RT1035
3RT1036
3RA1924-2B
3RA1933-2A
3/16
3/16
3/16
3/63
3/64
Siemens IC 10 AO 2014
3/61
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Fully wired and tested contactor assemblies Size S3 up to 45 kW
Rated data AC-2 and AC-3
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
Article No.
500 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation at 50/60 Hz
3RA134.-8XB30-1. . .
1)
65
18.5
30
37
45
24 AC
110 AC
230 AC
B
B
B
3RA1344-8XB30-1AC2
3RA1344-8XB30-1AG2
3RA1344-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
80
22
37
45
55
24 AC
110 AC
230 AC
B
B
B
3RA1345-8XB30-1AC2
3RA1345-8XB30-1AG2
3RA1345-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
95
22
45
55
55
24 AC
110 AC
230 AC
B
B
B
3RA1346-8XB30-1AC2
3RA1346-8XB30-1AG2
3RA1346-8XB30-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
30
37
45
37
45
55
45
55
55
24 DC
24 DC
24 DC
B
B
B
3RA1344-8XB30-1BB4
3RA1345-8XB30-1BB4
3RA1346-8XB30-1BB4
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
DC operation
65
80
95
18.5
22
22
6
16
1
5
2
NSB0_00462b
15
4
14
12
The connecting
cables are
not shown.
14
6
Page
3/63
3/34
3/38
3/43
Individual parts
1 2
1 2
1 2
4
Contactor, 30 kW
Contactor, 37 kW
Contactor, 45 kW
Mech. interlock,
lateral
5 6
Siemens IC 10 AO 2014
Page
Q2
3RT1044
3RT1045
3RT1046
3RT1044
3RT1045
3RT1046
3RA1924-2B
Assembly kit
3RA1943-2A
The assembly kit contains:
5
6
3/62
Article No.
Q1
3/17
3/17
3/17
3/63
3/64
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
Components for customer assembly
For
Size
contactors
Version
Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
Type
Mechanical interlocks
3RA1924-1A mounted
onto 2 contactors
S0
S2
S3
}
Laterally mountable1)
Each with one auxiliary contact
(1 NC contact) per contactor (can only be
used to connect contactors which are not
more than 1 size larger or smaller).
The mounting depth of the smaller
contactor has to be adapted.)
3RA1924-2B
1 unit
41B
3RT102
3RT103
3RT104
3RT132
3RT152
S0
S2
S3
3RA1924-1A
1 unit
41B
3RT1.5
3RT1.6
3RT1.7
S6
S10
S12
Laterally mountable,
without auxiliary contacts
Contactor sizes S6, S10 and S12 can be
interlocked with each other as required;
no adaptation of mounting depth is
necessary. Contactor clearance 10 mm.
3RA1954-2A
1 unit
41B
3RT104.-A S3
with
with
3RT105
S6
3RA1954-2C
1 unit
41B
3RT103
3RT104
S2, S3
3RA1923-3B
1 unit
41B
3RT105
3RT1.6
3RT1.7
S6
S10
S12
3RA1952-2A
3RA1962-2A
3RA1972-2A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3RT102
3RT103
3RT104
3RT132
3RT134
3RT144
3RT152
3RT153
Note:
Size S0:
Wiring modules must be mounted first.
Sizes S2 and S3:
Use 3RA1932-2C mechanical connector.
3RA1954-2A
3RA1954-2C
3RA1923-3B
Base plates
1)
Can also be used for 4-pole contactors with sizes S2 and S3.
2)
B
B
B
Siemens IC 10 AO 2014
3/63
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
For
Size
contactors
Version
DT Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
Type
3RA1913-2A
1 unit
41B
3RT102
S0
3RA1923-2A
1 unit
41B
3RT103
S2
3RA1933-2A
1 unit
41B
3RT104
S3
3RA1943-2A
1 unit
41B
3RT105
S6
3RA1953-2A
1 unit
41B
3RT105
3RT1.6
3RT1.7
S6
S10
S12
A
A
A
3RA1953-2M
3RA1963-2A
3RA1973-2A
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
NSB00468
3RT101
NSB00469
3RA1913-2A
NSB0_00470
3RA1923-2A
NSB0_00471
3RA1933-2A
NSB0_01724
3RA1943-2A
NSB0_01725
3RA1953-2A
3RA1953-2M
3/64
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA13 reversing contactor assemblies
For
Size
contactors
Contac- Version
tor clearance
Type
mm
DT Article No.
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
3RT101
3RT102
3RT103
3RT104
Top (in-phase)
3RA1913-3D
1 5 units
41B
3RA1913-3E
1 5 units
41B
S0-S0
and
S0-S0
0
and
10
Top (in-phase)
3RA1923-3D
1 5 units
41B
3RA1923-3E
1 5 units
41B
S2-S2
10
Top (in-phase)
3RA1933-3D
1 unit
41B
3RA1933-3E
1 unit
41B
Top (in-phase)
3RA1943-3D
1 unit
41B
3RA1943-3E
1 unit
41B
3RA1953-3D
1 unit
41B
3RA1953-3P
1 unit
41B
S3-S3
S6-S6
10
10
NSB0_01834
3RT105
S00-S00 0
NSB0_01835
3RA1953-3D
3RA1953-3P
For
Size
contactors
Contactor Interlocking
clearance
Type
mm
Version
DT Article No.
Mechanical connectors
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
1 10 units
41B
3RT1.11)
S00-S00 0
3RT1.2
S0-S0
Lateral
For 3- and
}
4-pole contactors
3RA1912-2H
0
102)
On front
For 3- and
A
4-pole contactors }
3RA1922-2C
1 10 units
41B
3RT1922-2D
100 20 units
41B
3RA1912-2H
Lateral
3RA1922-2C
3RT1.3
3RT1.4
S2-S2
S3-S3
On front
For 3-pole
contactors
3RA1932-2C
1 10 units
41B
3RT1.3
3RT1.4
3RT1.5
S2-S2
S3-S3
S6-S6
10
Lateral
For 3-pole
contactors
3RA1932-2D
1 10 units
41B
3RT1.3
S2-S2
10
Lateral
For 4-pole
contactors
3RA1932-2G
1 10 units
41B
3RT1.4
S3-S3
10
Lateral
For 4-pole
contactors
3RA1942-2G
1 10 units
41B
3RA1932-2C
3RA1932-2D
3RA1932-2G
3RA1942-2G
1)
2)
The connector function can be fulfilled with the wiring modules for size S0,
a contactor clearance of 10 mm and a lateral interlock.
Siemens IC 10 AO 2014
3/65
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Overview
These 3RA14 contactor assemblies for wye-delta starting are
designed for standard applications.
Note:
Contactor assemblies for wye-delta starting in special applications such as very heavy starting1) or wye-delta starting of special motors must be customized. Help with designing such special applications is available from Technical Assistance.
The 3RA14 contactor assemblies for wye-delta starting can be
ordered as follows:
Sizes S00 to S3
Fully wired and tested, with electrical interlock, dead interval
of up to 10 s on reversing (size S00 with electrical and mechanical interlocks)
As individual parts for customer assembly
Sizes S6 to S12
Only as individual parts for customer assembly
Rated data
at 50 Hz 400 V AC
For effective support from Technical Assistance, you must provide the
following details:
- Rated motor voltage
- Rated motor current
- Service factor, operating values
- Motor starting current factor
- Starting time
- Ambient temperature
Size
Rating P
Operational
current Ie
Motor current
kW
Article No.
complete
3RT1015
3RA1415-8XB31-1. . .
5.5
12
7.5
17
12.1 ... 17
11
25
19
15
32
24.1 ... 34
18.5
40
34.5 ... 40
22
50
31
30
50
48.3 ... 65
37
80
45
86
69
55
115
75
150
90
160
86
... 160
110
195
86
... 195
132
230
86
... 230
3RT1055
3RT1045
160
280
86
... 280
3RT1056
3RT1046
200
350
95
... 350
250
430
95
... 430
315
540
277
... 540
355
610
277
... 610
400
690
277
... 690
500
850
277
... 850
3/66
Siemens IC 10 AO 2014
... 25
... 43
S00-S00-S00
S0-S0-S0
3RT1024
3RA1416-8XB31-1. . .
3RT1024
3RT1026
S2-S2-S0
3RT1034
3RT1026
3RT1036
S3-S3-S2
S10-S10-S6
S12-S12-S10
3RA1434-8XC21-1. . .
--
3RT1034
S2-S2-S2
3RA1423-8XC21-1. . .
3RA1425-8XC21-1. . .
3RT1034
... 86
3RT1015
3RT1017
3RA1435-8XC21-1. . .
3RA1436-8XC21-1. . .
3RT1044
3RT1035
3RA1444-8XC21-1. . .
3RT1045
3RT1036
3RA1445-8XC21-1. . .
3RT1054
3RT1044
--
3RT1064
3RT1054
3RT1065
3RT1055
3RT1075
3RT1064
3RT1065
3RT1076
3RT1066
---
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
The overload relay can be either mounted onto the Q1 line contactor or fitted separately. It must be set to 0.58 times the rated
motor current.
Note:
The selection of contactor types refers to fused configurations.
The wiring kits for sizes S00 and S0 contain the top and bottom
main conducting path connections between the line and delta
contactors (top) and between the delta and star contactors (bottom).
Sizes S00 to S3
All contactor assemblies can be fitted with RC elements, varistors or diode assemblies for damping opening surges in the coil.
As with the individual contactors, the surge suppressors can either be plugged onto the top of the contactors (S00) or fitted onto
the coil terminals on the top or bottom (S0 to S3).
Sizes S6 to S12
The contactors are fitted with varistors as standard.
Motor protection
Overload relays or thermistor motor protection releases can be
used for overload protection.
Accessories for
customer assembly
Timing relays
P
kW
5.5 3RT1916-2G.51 --
3RA1913-2B 1) --
Base plates
--
7.5 3RP1574-1N.30
11
3RP1574-1N.30 --
3RA1923-2B 2) --
--
15
18.5
22
3RT1926-4BA31 3RA1932-2E
30
37
3RT1936-4BA31 3RA1932-2F
45
55
3RP1574-1N.30 3RA1943-2C 3) --
3RT1936-4BA31 3RA1942-2E
75
90
Setting
range
A
Article No.
5.5 ... 8
3RU1116-1HB0
3RU1116-1JB0
... 10
11
... 16
3RU1126-4AB0
14
... 20
3RU1126-4BB0
20
... 25
3RU1126-4DB0
18
... 25
3RU1136-4DB0
28
... 40
3RU1136-4FB0
36
... 45
3RU1136-4GB0
40
... 50
3RU1136-4HB0
45
... 63
3RU1146-4JB0
70
... 90
3RU1146-4LB0
3RP1574-1N.30 --
--
--
3RP1574-1N.30 --
--
--
--
... 12 3RB2016-1SB0
... 25 3RB2026-1QB0
50
110
132
160
200
3RT1956-4BA31 3RA1962-2E
250
315
3RP1574-1N.30 --
--
3RT1966-4BA31 3RA1972-2E
--
--
55
160
160
355
400
500
1)
2)
Assembly kit contains 5 connecting clips; wiring modules on the top (connection between line and delta contactor) and on the bottom (connection
between delta and star contactor); star jumper.
3)
4)
Siemens IC 10 AO 2014
3/67
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
Article No.
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation, 50/60 Hz
12
3.3
5.5
7.2
9.2
24 AC
110 AC
230 AC
B
B
B
3RA1415-8XB31-1AB0
3RA1415-8XB31-1AF0
3RA1415-8XB31-1AP0
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
17
4.7
7.5
10.3
9.2
24 AC
110 AC
230 AC
B
B
D
3RA1416-8XB31-1AB0
3RA1416-8XB31-1AF0
3RA1416-8XB31-1AP0
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
5.5
7.5
7.2
10.3
9.2
9.2
24 DC
24 DC
B
}
3RA1415-8XB31-1BB4
3RA1416-8XB31-1BB4
1
1
1 unit
1 unit
41B
41B
3RA141.-8XB31-1. . .
DC operation
12
17
1)
3.3
4.7
6
17
1
2
14
NSB0_00463a
14
14
9
4
14
16
Article No.
3/34
3/42
Individual parts
Article No.
Page
Q11)
Q32)
Q22)
3RT1015
3RT1017
3RT1015
3RT1017
3RT1015
3RT1015
1 2 3
1 2 3
Contactor, 5.5 kW
Contactor, 7.5 kW
Solid-state time-delay
auxiliary switch block,
front
3RT1916-2G.51
Auxiliary switch block with
1 unassigned NO contact 3RH1911-1BA10
Assembly kit
3RA1913-2B
3/73
9
4 5 6
3/14
3/14
3/40
3/34
3/73
2)
3/68
Siemens IC 10 AO 2014
Mechanical interlocks
3 connecting clips
Wiring modules on the top and bottom for connecting the
main and control conducting paths
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Fully wired and tested contactor assemblies Size S0-S0-S0 up to 18.5 kW
Rated control DT Screw terminals
supply voltage
Us1)
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation, 50/60 Hz
3RA142.-8XC21-1. . .
25
7.1
11
15.6
19
24 AC
110 AC
230 AC
B
B
C
3RA1423-8XC21-1AC2
3RA1423-8XC21-1AG2
3RA1423-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
32 / 40
11.4
15 /
18.5
19
19
24 AC
110 AC
230 AC
A
A
}
3RA1425-8XC21-1AC2
3RA1425-8XC21-1AG2
3RA1425-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
11
15 /
18.5
15.6
19
19
19
24 DC
24 DC
}
A
3RA1423-8XC21-1BB4
3RA1425-8XC21-1BB4
1
1
1 unit
1 unit
41B
41B
DC operation
25
32 / 40
1)
7.1
11.4
16
6
17
6
5
1
18
NSB0_00464c
15
10
4
9
10
19
10
8
7
12
15
16
17
18
19
12
4
7
19
Article No.
3RA1924-2B
3RT1926-2G. . .
3RA1924-1A
3RH1921-1EA. .
3RT1926-1. . . .
3RV1915-5A
3RT1926-4CC20
3/40
3/63
3/38
3/42
3/73
3/73
3RP1903
4)
Individual parts
1 2 3
1 2 3
8
9
10
5 6
Article No.
Page
Q1
Q3
Q2
Contactor, 11 kW
Contactor, 15/18.5 kW
3RT1024
3RT1026
3RT1024
3RT1026
3RT1024
3RT1024
3RP1574-1N.30
3/15
3/15
4)
3RH1921-1CA10
3/37
3RH1921-1CA01
3RH1921-1CA10
3RA1923-2B
3/37
3/73
2)
17 and 18 can only be mounted with contactors with screw terminal (coil).
3)
Not included in the scope of supply of the preassembled contactor assemblies; can be ordered as an accessory.
4)
Connecting clips
Wiring modules on the top and bottom for connecting the
main and control conducting paths
Siemens IC 10 AO 2014
3/69
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Fully wired and tested contactor assemblies Size S2-S2-S0 up to 30 kW
Rated data AC-3
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
22 / 30 35
34
24 AC
110 AC
230 AC
A
A
}
22 / 30 35
34
24 DC
PU
(UNIT,
SET,
M)
PS*
PG
3RA1434-8XC21-1AC2
3RA1434-8XC21-1AG2
3RA1434-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3RA1434-8XC21-1BB4
1 unit
41B
Article No.
Price
per PU
AC operation, 50/60 Hz
50 / 65
19.6
DC operation
50 / 65
19.6
3RA1434-8XC21-1. . .
1)
16
17
11
18
19
NSB0_00465d
15
10
9
10
10
8
6
Article No.
3RA1924-2B
3/63
3RT1926-2G. . .
3RH1921-1EA. .
3RT1926-1. . . .
3RT1936-1. . . .
3RV1935-5A
3RV1935-1A
3/40
3/38
3/42,
3/43
3/73
3/73
3RV1903
4)
Individual parts
1 2 3
8
9
10
11
6
1)
2)
3)
3/70
Siemens IC 10 AO 2014
Article No.
Page
Q1
Q3
Q2
Contactor, 22/30 kW
3RT1034
3RT1034
3RT1026
3RP1574-1N.30
3)
3RH1921-1CA10
3/37
3RH1921-1CA01
3RH1921-1CA10
3RA1932-2E
3RA1933-2C
3/37
3/37
3/73
3/73
3/15
The assembly kit contains the star jumper on the top and the wiring
module on the bottom for connecting the main current paths.
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Fully wired and tested contactor assemblies Size S2-S2-S2 up to 45 kW
Rated control DT Screw terminals
supply voltage
Us1)
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation, 50/60 Hz
80
25
37
51
63
24 AC
110 AC
230 AC
A
A
}
3RA1435-8XC21-1AC2
3RA1435-8XC21-1AG2
3RA1435-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
86
27
45
55
63
24 AC
110 AC
230 AC
A
A
}
3RA1436-8XC21-1AC2
3RA1436-8XC21-1AG2
3RA1436-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
37
45
51
55
63
63
24 DC
24 DC
A
A
3RA1435-8XC21-1BB4
3RA1436-8XC21-1BB4
1
1
1 unit
1 unit
41B
41B
DC operation
3RA143.-8XC21-1. . .
80
86
1)
25
27
1
17
16
11
18
19
NSB0_00466c
15
10
9
4
10
10
8
12
Article No.
Individual parts
Article No.
Page
Q1
Q3
Q2
3RT1035
3RT1036
3RT1034
3RT1034
3RA1924-2B
3/63
1 2 3
1 2 3
Contactor, 37 kW
Contactor, 45 kW
3RT1035
3RT1036
3RT1926-2G. . .
3RA1924-1A
3RH1921-1EA. .
3RT1926-1. . . .
3RT1936-1. . . .
3RV1935-5A
3RV1935-1A
3/40
3/63
3/38
3/42,
3/43
3/73
3/73
3RP1574-1N.30
2)
3RH1921-1CA10
3/37
3RP1903
2)
3RH1921-1CA01
3RH1921-1CA10
3RA1932-2F
3RA1933-2B
3/37
3/37
3/73
3/73
9
10
11
6
3/16
3/16
The assembly kit contains the star jumper on the top and the wiring
module on the bottom for connecting the main current paths.
1)
2)
Siemens IC 10 AO 2014
3/71
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Fully wired and tested contactor assemblies Size S3-S3-S2 up to 75 kW
Rated data AC-3
Operational
current Ie
up to
Ratings of
three-phase motors
at 50 Hz and
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
AC operation, 50/60 Hz
115
37
55
81
93
24 AC
110 AC
230 AC
B
B
}
3RA1444-8XC21-1AC2
3RA1444-8XC21-1AG2
3RA1444-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
150
47
75
103
110
24 AC
110 AC
230 AC
B
B
}
3RA1445-8XC21-1AC2
3RA1445-8XC21-1AG2
3RA1445-8XC21-1AL2
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
55
75
81
103
93
110
24 DC
24 DC
B
B
3RA1444-8XC21-1BB4
3RA1445-8XC21-1BB4
1
1
1 unit
1 unit
41B
41B
DC operation
115
150
3RA144.-8XC21-1. . .
1)
37
47
Coil operating range at 50 Hz: 0.8 ... 1.1 x Us; at 60 Hz: 0.85 ... 1.1 x Us.
16
11
20
19
NSB0_00467d
15
10
8
9
10
10
7
15
16
19
20
Article No.
3RA1924-2B
3RT1926-2G. . .
3RH1921-1EA. .
3RT19.6-1 . . . .
3/40
3/38
3/43
3RP1903
3RA1943-3L
3)
3/73
Individual parts
Article No.
Page
Q1
Q3
Q2
3RT1044
3RT1045
3RT1035
3RT1036
1 2 3
1 2 3
Contactor, 55 kW
Contactor, 75 kW
3RT1044
3RT1045
8
9
3RP1574-1N.30
3)
3RH1921-1CA10
3/37
3RH1921-1CA01
3RH1921-1CA10
3RA1942-2E
3RA1943-2C
3/37
3/37
3/73
3/73
10
11
6
3/16
3/16
The assembly kit contains the star jumper on the top and the wiring
module on the bottom for connecting the main current paths.
1)
2)
3/72
Siemens IC 10 AO 2014
3)
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
SIRIUS 3RA14 contactor assemblies
for wye-delta starting
Components for customer assembly
Version
Size
DT Article No.
S00-S00-S00
S0-S0-S0
Price
per PU
PU
(UNIT,
SET,
M)
PS*
PG
3RA1913-2B
1 unit
41B
3RA1923-2B
1 unit
41B
S2-S2-S0
S2-S2-S2
S3-S3-S2
}
}
}
3RA1933-2C
3RA1933-2B
3RA1943-2C
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S3-S3-S3
3RA1943-2B
1 unit
41B
S6-S6-S6
3RA1953-2B
1 unit
41B
3RA1953-2N
1 unit
41B
3RA1963-2B
1 unit
41B
S12-S12-S12
3RA1973-2B
1 unit
41B
S3
3RA1943-3L
1 unit
41B
S00
S0
S2
}
}
}
3RA1913-3K
3RV1925-5AB
3RV1935-5A
1
1
1
1 unit
1 unit
1 unit
41B
41E
41E
D
}
3RT1926-4CC20
3RV1935-1A
1
1
1 unit
1 unit
41B
41E
S00
S0
S2
}
}
}
3RT1916-4BA31
3RT1926-4BA31
3RT1936-4BA31
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
S3
S61)
S10, S121)
}
}
}
3RT1946-4BA31
3RT1956-4BA31
3RT1966-4BA31
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
NSB0_01836
Assembly kits
NSB0_01837
3RA1953-2B
3RA1953-2N,
3RA1963-2B,
3RA1973-2B
Three-phase busbars
Bridging phase-by-phase of all input terminals of
S0
the line contactor (Q1) and the delta contactor (Q3) S2
3RT1936-4BA31
Base plates
For customer assembly of contactor assemblies for wye-delta starting
with a laterally mounted timing relay
Side-by-side mounting
S2, S2, S0
3RA1932-2E
1 unit
41B
S2, S2, S2
3RA1932-2F
1 unit
41B
Side-by-side mounting
S3, S3, S2
3RA1942-2E
1 unit
41B
S6, S6, S3
S6, S6, S6
S10, S10, S6
B
B
B
3RA1952-2E
3RA1952-2F
3RA1962-2E
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
B
B
B
3RA1962-2F
3RA1972-2E
3RA1972-2F
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
B
B
B
3RA1932-2B
3RA1932-2B
3RA1942-2B
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
1)
S2, S2, S0
S2, S2, S2
S3, S3, S2
The 3RT1956-4EA1 (for S6) or 3RT1966-4EA1 (for S10 and S12) cover can
be used for touch protection.
Siemens IC 10 AO 2014
3/73
Siemens AG 2014
Contactor Assemblies
3RA13, 3RA14 Contactor Assemblies
Notes
3/74
Siemens IC 10 AO 2014
Siemens AG 2014
Price groups
PG 41B
4/4
4/6
4/8
4/10
4/13
Ch.5
Ch.3
Ch.5
Introduction
Contactors for special
applications
SIRIUS 3RT14 contactors for resistive
loads (AC-1), 3-pole, 140 ... 690 A
SIRIUS 3RT13 contactors for resistive
loads (AC-1), 4-pole, 4 NO, 18 ... 140 A
SIRIUS 3RT15 contactors, 4-pole,
2 NO + 2 NC, 4 ... 18.5 kW
SIRIUS 3RT16 capacitor contactors,
12.5 ... 50 kvar
Contactors with extended
operating range 0.7 ... 1.25 Us
for railway applications
SIRIUS 3RT10 motor contactors,
5.5 ... 45 kW
SIRIUS 3RH11 contactor relays
Coupling contactors
SIRIUS 3RT10 coupling contactors
(interface), 3-pole, 3 ... 11 kW
SIRIUS 3RH11 coupling contactors
for switching auxiliary circuits,
4-pole
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
4/2
Siemens AG 2014
Overview
Size
Type
S00
3RT131, 3RT151
S0
3RT132, 3RT152
3RT1316
4 NO
2 NO + 2 NC
4 NO
2 NO + 2 NC
AC, DC operation
(p. 4/9)
(p. 4/9)
3RT1317
3RT1516
3RT1517
3RT1325
3RT1326
3RT1526
AC-1
Ie at 400 V
22 / 20
18 / 16
22 / 20
35 / 30
40 / 35
40 / 35
40 C
kW 12
18 / 16
14.5
11
13
22
26
26
60 C
kW
11
13
6.5
20
23
15
12
17
25
25
11
11
7.5
400 V
kW
5.5
12
5.5
7.5
230 V
kW
5.5
5.5
On front
Lateral
(Chapter 3)
(Chapter 3)
3RH1911
3RH1911
(Chapter 3)
(Chapter 3)
3RH1921
3RH1921
3RT1916
(Chapter 3)
3RT1926
(Chapter 3)
Surge suppressors
3RT1916
(Chapter 3)
3RT1926
(Chapter 3)
Size
Type
S2
3RT1336, 3RT1535
S3
3RT134.
3RT1336
3RT1535
3RT1344
3RT1446
3RT1456
4 NO
2 NO + 2 NC
4 NO
3 NO
3 NO
AC, DC operation
(p. 4/4)
(p. 4/4)
3RT1346
3RT1466
3RT1476
AC-1 ( 690 V)
40 C
60
60
110
140
140
275
400
690
60 C
55
55
100
120
130
250
380
650
400 V
40 C
kW 39
36
72
92
92
180
263
454
230 V
500 V
690 V
1000 V
40 C
kW
kW
kW
kW
20
----
42
----
53
----
53
115
159
98
105
225
310
165
151
329
454
247
261
568
783
410
44
97
138
170
22
55
75
90
12.7
29.9
38.2
30
55
90
37
90
132
55
110
160
Ie
60 C
23
----
400 V
kW 11
18.5
230 V
500 V
690 V
kW
kW
kW
9.5
---
5.5
---
----
----
On front
Lateral
3RH1921
3RH1921
(Chapter 3)
(Chapter 3)
(Chapter 3) 3RT1946-4EA4
Terminal covers
3RT1936-4EA4
--
Surge suppressors
3RT1926/36
4/2
Siemens IC 10 AO 2014
-(Chapter 3)
(Chapter 3) 3RT1956-4EA1/2/3
(Chapter 3)
3RT1955/56/66-4G
(Chapter 3)
Siemens AG 2014
Siemens IC 10 AO 2014
4/3
Siemens AG 2014
Overview
Size S3: AC or DC operation
Sizes S6 to S12: AC/DC operation
Standards
IEC 60947-1, EN 60947-1,
IEC 60947-4-1, EN 60947-4-1,
IEC 60947-5-1, EN 60947-5-1 (auxiliary switches)
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274.
3RT14 contactors are used for switching resistive loads (AC-1)
or as contactors, for example for variable-speed operating
mechanisms that normally only have to carry the current.
3RT1446-1A. .0
Size
Auxiliary
contacts
Version
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
Up to
690 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
NO
NC
S3
140
53
92
115
159
--
--
AC 24, 50 Hz B
AC 110, 50 Hz B
AC 230, 50 Hz }
3RT1446-1AB00
3RT1446-1AF00
3RT1446-1AP00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
92
115
159
--
--
24 DC
220 DC
}
B
3RT1446-1BB40
3RT1446-1BM40
1
1
1 unit
1 unit
41B
41B
DC operation
A1(+) 1/L1 3/L2 5/L3
A2()
S3
140
53
4/4
Siemens IC 10 AO 2014
Siemens AG 2014
3RT146.
Size
Auxiliary
contacts
Version
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
Up to
690 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
NO
NC
A1(+)
A2()
S6
275
105
180
225
310
}
}
3RT1456-6AF36
3RT1456-6AP36
1
1
1 unit
1 unit
41B
41B
S10
400
151
263
329
454
}
}
3RT1466-6AF36
3RT1466-6AP36
1
1
1 unit
1 unit
41B
41B
S12
690
261
454
568
783
A
}
3RT1476-6AF36
3RT1476-6AP36
1
1
1 unit
1 unit
41B
41B
A1(+)
A2()
S6
275
105
180
225
310
96 ... 127
200 ... 277
B
A
3RT1456-6NF36
3RT1456-6NP36
1
1
1 unit
1 unit
41B
41B
S10
400
151
263
329
454
96 ... 127
200 ... 277
B
A
3RT1466-6NF36
3RT1466-6NP36
1
1
1 unit
1 unit
41B
41B
S12
690
261
454
568
783
96 ... 127
200 ... 277
B
A
3RT1476-6NF36
3RT1476-6NP36
1
1
1 unit
1 unit
41B
41B
S6
275
105
180
225
310
96 ... 127
200 ... 277
B
B
3RT1456-6PF35
3RT1456-6PP35
1
1
1 unit
1 unit
41B
41B
S10
400
151
263
329
454
3RT1466-6PP35
1 unit
41B
S12
690
261
454
568
783
3RT1476-6PP35
1 unit
41B
S6
275
105
180
225
310
96 ... 127
200 ... 277
B
B
3RT1456-6QF35
3RT1456-6QP35
1
1
1 unit
1 unit
41B
41B
S10
400
151
263
329
454
3RT1466-6QP35
1 unit
41B
S12
690
261
454
568
783
3RT1476-6QP35
1 unit
41B
Siemens IC 10 AO 2014
4/5
Siemens AG 2014
Overview
Standards
IEC 60947-1, EN 60947-1,
IEC 60947-4-1, EN 60947-4-1,
IEC 60947-5-1, EN 60947-5-1 (auxiliary switches)
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274.
3RT13 contactors are used for switching resistive loads (AC-1)
but are also suitable for switching mixed loads in distribution
systems (e. g. for supplying heaters, lamps, motors, PC power
supply units) with p.f. > 0.8 according to IEC 60947-4-1, test
conditions for utilization category AC-1.
Accessories
The accessories for the 3-pole SIRIUS 3RT10 contactors can
also be used for the 4-pole versions (see Chapter 3).
Auxiliary switches
Size S00: Snap-on auxiliary switch blocks according to
EN 50005. Sizes S0 to S3: Snap-on auxiliary switch blocks
according to EN 50012 and EN 50005 (for S0 max. 2 auxiliary
contacts).
3RT133.-1A.00
Rated data AC-1,
Tu: 40/60 C
Operational current
Ie
3RT131.-1A.00
Rated control supply
voltage Us
3RT131.-2A.00
DT Screw terminals
Article No.
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
400 V
A
kW
V AC
Size S001)
18 / 16
12 / 11
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
}
}
}
3RT1316-1AB00
3RT1316-1AF00
3RT1316-1AP00
B
B
B
3RT1316-2AB00
3RT1316-2AF00
3RT1316-2AP00
22 / 20
14.5 / 13
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
}
}
}
3RT1317-1AB00
3RT1317-1AF00
3RT1317-1AP00
B
B
B
3RT1317-2AB00
3RT1317-2AF00
3RT1317-2AP00
35 / 30
22 / 20
24, 50 Hz
110, 50 Hz
230, 50 Hz
}
}
}
3RT1325-1AB00
3RT1325-1AF00
3RT1325-1AP00
----
40 / 35
26 / 23
24, 50 Hz
110, 50 Hz
230, 50 Hz
}
}
}
3RT1326-1AB00
3RT1326-1AF00
3RT1326-1AP00
----
39 / 36
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1336-1AB00
3RT1336-1AF00
3RT1336-1AP00
----
110 / 100
72 / 66
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1344-1AB00
3RT1344-1AF00
3RT1344-1AP00
----
140 / 120
92 / 79
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1346-1AB00
3RT1346-1AF00
3RT1346-1AP00
----
Size S02)
Size S2
60 / 55
Size S3
1)
4/6
Siemens IC 10 AO 2014
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT134.-1B..40
Rated data AC-1,
Tu: 40/60 C
Operational
current Ie
3RT131.-1B.40
Rated control supply
voltage Us
3RT131.-2B.40
DT Screw terminals
Article No.
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
400 V
A
kW
V DC
Size S00
18 / 16
12 / 11
24
220
}
B
3RT1316-1BB40
3RT1316-1BM40
}
B
3RT1316-2BB40
3RT1316-2BM40
22 / 20
14.5 / 13
24
220
}
B
3RT1317-1BB40
3RT1317-1BM40
A
B
3RT1317-2BB40
3RT1317-2BM40
35 / 30
22 / 20
24
220
}
B
3RT1325-1BB40
3RT1325-1BM40
---
40 / 35
26 / 23
24
220
}
B
3RT1326-1BB40
3RT1326-1BM40
---
39 / 36
24
220
}
B
3RT1336-1BB40
3RT1336-1BM40
---
110 / 100
72 / 66
24
220
B
B
3RT1344-1BB40
3RT1344-1BM40
---
140 / 120
92 / 79
24
220
B
B
3RT1346-1BB40
3RT1346-1BM40
---
Size S01)
Size S2
60 / 55
Size S3
1)
Siemens IC 10 AO 2014
4/7
Siemens AG 2014
Overview
Standards
IEC 60947-1, EN 60947-1,
IEC 60947-4-1, EN 60947-4-1
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274.
Note:
Single device for pole reversal; not suitable for reversing duty.
3RT15 contactors are not suitable for switching a load between
two current sources.
Accessories
The accessories for the 3-pole SIRIUS 3RT10 contactors can
also be used for the 4-pole versions (see Chapter 3).
Auxiliary switches
Size S00: Snap-on auxiliary switch blocks according to
EN 50005.
Sizes S0 to S3: Snap-on auxiliary switch blocks according to
EN 50012 and EN 50005 (for S0 max. 2 auxiliary contacts).
4/8
Siemens IC 10 AO 2014
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT1526-1A..0
Rated data
AC-2/AC-3,
Tu: Up to 60 C
AC-1,
Tu: 40/60 C
Operational
current Ie
Ratings of
three-phase motors
at 50 Hz and
At 400 V
400 V
kW
3RT151.-1...0
Rated control supply
voltage Us
DT Screw terminals
Operational
current Ie
3RT151.-2...0
Article No.
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
A2() 2
R2 R4 4
Size S002)
9
18 / 16
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1516-1AB00
3RT1516-1AF00
3RT1516-1AP00
B
B
B
3RT1516-2AB00
3RT1516-2AF00
3RT1516-2AP00
12
5.5
22 / 20
24, 50 Hz
110, 50 Hz
230, 50 Hz
A
}
}
3RT1517-1AB00
3RT1517-1AF00
3RT1517-1AP00
B
B
}
3RT1517-2AB00
3RT1517-2AF00
3RT1517-2AP00
11
40 / 35
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1526-1AB00
3RT1526-1AF00
3RT1526-1AP00
----
18.5
55 / 50
24, 50 Hz
110, 50 Hz
230, 50 Hz
B
B
}
3RT1535-1AB00
3RT1535-1AF00
3RT1535-1AP00
----
Size S03)
25
Size S2
40
DC operation
A1(+) 1 R1 R3 3
A2() 2
R2 R4 4
Size S00
9
18 / 16
24 DC
220 DC
}
B
3RT1516-1BB40
3RT1516-1BM40
}
B
3RT1516-2BB40
3RT1516-2BM40
12
5.5
22 / 20
24 DC
220 DC
}
B
3RT1517-1BB40
3RT1517-1BM40
B
B
3RT1517-2BB40
3RT1517-2BM40
11
40 / 35
24 DC
220 DC
}
B
3RT1526-1BB40
3RT1526-1BM40
---
18.5
55 / 50
24 DC
220 DC
}
B
3RT1535-1BB40
3RT1535-1BM40
---
Size S03)
25
Size S2
40
1)
Single device for pole reversal; not suitable for reversing duty.
For size S00: Coil operating range
at 50 Hz: 0.8 ... 1.1 x Us
at 60 Hz: 0.85 ... 1.1 x Us.
3) Minimum conductor cross-section 10 mm.
2)
Siemens IC 10 AO 2014
4/9
Siemens AG 2014
Overview
Standards
Circuit diagrams
Size S00
Sizes S0 and S3
L1 L2 L3
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274.
L1 L2 L3
F0
F0
14 52
A1
1/L1
3/L2
5/L3
13 51
A2
2/T1
4/T2
6/T3
A2
1/L1
3/L2
5/L3
A1
2/T1
4/T2
6/T3
4/10
Siemens IC 10 AO 2014
C1
NSB0_00558b
NSB0_01382c
Function
C1
43
44
Siemens AG 2014
AC operation
Screw terminals
3RT1617-1A.03
3RT1627-1A.01
Auxiliary
contacts,
unassigned
Capacitor rating at
operational voltage 50/60 Hz
Version
At 230 V
At 400 V
At 525 V
At 690 V
kvar
kvar
kvar
kvar
NO
3RT1647-1A.01
Rated control supply
voltage Us2)
DT Screw terminals
Article No.
NC
V AC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
Hz
For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Size S00
3 7.5
5 12.5
7.5 15
10 21
24
110
230
50 / 60
B
B
}
3RT1617-1AB03
3RT1617-1AF03
3RT1617-1AP03
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
6 25
7.8 30
10 42
--
24
110
230
50
B
B
}
3RT1627-1AB01
3RT1627-1AF01
3RT1627-1AP01
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
5 50
7.5 60
10 84
--
24
110
230
50
B
B
}
3RT1647-1AB01
3RT1647-1AF01
3RT1647-1AP01
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
Size S03)
3.5 15
Size S3
3.5 30
1)
Siemens IC 10 AO 2014
4/11
Siemens AG 2014
Options
Rated control supply voltages, possible on request (change of the 10th and 11th position of the Article No.)
Rated control supply
voltage Us
3RT132,
3RT152
3RT133,
3RT134,
3RT153
3RT144
3RT1617,
3RT1627,
3RT1647
S0
S2, S3
S3
S00, S0, S3
B0
D0
H0
F0
P0
U0
V0
B0
D0
H0
F0
P0
U0
V0
B0
--F0
P0
U0
V0
B0
D0
H0
F0
P0
U0
V0
B0
--F0
P0
U0
V0
B0
D0
H0
F0
N2
P0
P2
C2
D2
H2
G2
N2
L2
P2
C2
D2
H2
G2
N2
L2
P2
C2
D2
H2
G2
N2
L2
P2
C2
--G2
N2
L2
P2
K6
P6
K6
P6
K6
P6
K6
P6
K6
P6
G6
N6
R6
G6
N6
R6
G6
N6
R6
G6
N6
R6
G6
N6
R6
A4
B4
D4
W4
-F4
G4
M4
P4
-B4
D4
--F4
G4
M4
--
-B4
D4
W4
-F4
G4
M4
P4
-B4
D4
W4
E4
F4
G4
M4
P4
----------
Size S00
Sizes S00 to S3
AC operation
60 Hz
110 V AC
220 V AC
120 V AC
240 V AC
60 Hz4)
100 V AC
200 V AC
400 V AC
110 V AC
220 V AC
440 V AC
DC operation
12 V DC
24 V DC
42 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC
230 V DC
Examples
AC operation
DC operation
3RT1325-1AP00
Contactor with screw terminals; with solenoid coil for 50 Hz for rated control supply voltage 230 V AC.
3RT1325-1AG20
Contactor with screw terminals; with solenoid coil for 50/60 Hz for rated control supply voltage 110 V AC.
3RT1526-2BB40
Contactor with spring-type terminals; for rated control supply voltage 24 V DC.
3RT1526-2BG40
Contactor with spring-type terminals; for rated control supply voltage 125 V DC.
3RT1456-6P...,
3RT1466-6P...,
3RT1476-6P...
Size
Sizes S6 to S12
UC operation (AC 50 to 60 Hz, DC)
23 ... 26 V AC/DC
42 ... 48 V AC/DC
110 ... 127 V AC/DC
200 ... 220 V AC/DC
220 ... 240 V AC/DC
B3
D3
F3
M3
P3
U3
V3
R3
S3
T3
1)
4/12
Siemens IC 10 AO 2014
3)
B3
F3
P3
-F3
P3
Siemens AG 2014
Overview
L+
L-
Standards
S1
E1+
K1
K1
A2-
The solenoid coils of the contactors have an extended coil operating range from 0.7 to 1.25 x Us and are fitted as standard with
varistors to provide protection against overvoltage. The opening
delay is therefore 2 to 5 ms longer than for standard contactors.
Ambient temperature
The permissible ambient temperature for operation of the contactors (across the full coil operating range) is -40 C to +70 C.
Uninterrupted duty at temperatures > +60 C reduces the mechanical endurance, the current carrying capacity of the conducting paths and the switching frequency.
Application
For operation in installations which are subject both to considerable variations in the control voltage and to high ambient temperatures, e. g. railway applications under extreme climatic conditions, rolling mills, etc.
Sizes S00 and S0 with conventional coil
These contactor relays have an extended operating range from
0.7 to 1.25 x Us; the coils are fitted with varistors as standard.
An additional series resistor is not required.
Please note:
Size S00: It is not possible to mount an auxiliary switch block.
Size S0: Up to two single-pole auxiliary switch blocks can be
mounted.
Mounting
A clearance of 10 mm is required for side-by-side mounting at
ambient temperatures > 60 C 70 C.
NSB0_00559b
Rv
Mounting
Auxiliary switches
Dimensions
Because of the built-on contactor control unit, the height of the
size S0 to S3 contactors increases by up to 34 mm.
Siemens IC 10 AO 2014
4/13
Siemens AG 2014
DC operation
Conventional solenoid coil, fitted with varistor
3RT103.-2K.40
Rated data
AC-2 and AC-3
Tu: 70 C
Operational
current Ie
at
Auxiliary
contacts
Ratings of
three-phase motors at
DT Spring-type terminals
Version
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
NO
Article No.
NC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
V DC
For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Size S00
Ident. No. 10, 1 NO
A1(+) 1/L1 3/L2 5/L3 13
A2()
12
5.5
5.5
5.5
11)
--
24
110
}
B
3RT1017-2KB41
3RT1017-2KF41
1
1
1 unit
1 unit
41B
41B
12
5.5
5.5
5.5
--
11)
24
110
}
B
3RT1017-2KB42
3RT1017-2KF42
1
1
1 unit
1 unit
41B
41B
Size S0
U
Spring-type terminals
for coil terminals
A1(+)
A2(-)
17
7.5
10
11
--
--2)
24
110
}
B
3RT1025-3KB40
3RT1025-3KF40
1
1
1 unit
1 unit
41B
41B
25
5.5
11
11
11
--
--2)
24
110
}
B
3RT1026-3KB40
3RT1026-3KF40
1
1
1 unit
1 unit
41B
41B
1)
2)
4/14
Siemens IC 10 AO 2014
Siemens AG 2014
Operational
current Ie
at
Auxiliary
contacts
Ratings of
three-phase motors at
3RT103.-3K.44-0LA0
DT Spring-type terminals
Version
400 V
230 V
400 V
500 V
690 V
kW
kW
kW
kW
NO
Article No.
NC
PU
(UNIT,
SET, M)
PS*
PG
1
1
1 unit
1 unit
41B
41B
Price
per PU
V DC
For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Size S00
E1(+)
A2()
12
5.5
5.5
5.5
--
--1)
24
110
B
B
Spring-type terminals
for coil terminals and
auxiliary contacts
Size S0
A1(+)
A2()
17
25
7.5
5.5
11
10
11
3RT1017-2KB42-0LA0
3RT1017-2KF42-0LA0
31 43
32 44
11
11
12)
24
110
B
B
3RT1025-3KB44-0LA0
3RT1025-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
12)
24
110
B
B
3RT1026-3KB44-0LA0
3RT1026-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
Size S2
A1(+)
A2()
31 43
32 44
32
7.5
15
18.5
18.5
12)
24
110
B
B
3RT1034-3KB44-0LA0
3RT1034-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
40
11
18.5
22
22
12)
24
110
B
B
3RT1035-3KB44-0LA0
3RT1035-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
50
15
22
30
22
12)
24
110
B
B
3RT1036-3KB44-0LA0
3RT1036-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
65
18.5
30
37
31 43
32 44
43
12)
24
110
B
B
3RT1044-3KB44-0LA0
3RT1044-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
2)
24
110
B
B
3RT1045-3KB44-0LA0
3RT1045-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
24
110
B
B
3RT1046-3KB44-0LA0
3RT1046-3KF44-0LA0
1
1
1 unit
1 unit
41B
41B
80
22
37
45
55
95
22
45
55
55
12)
1)
2)
The NC contact 21-22 is used for switching the series resistor. The auxiliary
contacts are not expandable.
Siemens IC 10 AO 2014
4/15
3RT103.-3K.44-0LA0
Rated data
AC-2 and AC-3
Tu: 70 C
Siemens AG 2014
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RT103.-3X.40-0LA2
Rated data
AC-2 and AC-3
Tu: Up to 70 C
Rated
operational
current Ie up to
Auxiliary
contacts1)
Ratings of
three-phase motors
at 50 Hz
400 V
400 V
kW
Version
NO
Article No.
NC
DT Spring-type terminals
for coil terminals
Price
per PU
Article No.
Price
per PU
V DC
A1(+)
A2(-)
17
7.5
---
---
24
110
B
B
3RT1025-1XB40-0LA2
3RT1025-1XF40-0LA2
B
B
3RT1025-3XB40-0LA2
3RT1025-3XF40-0LA2
25
11
---
---
24
110
B
B
3RT1026-1XB40-0LA2
3RT1026-1XF40-0LA2
B
B
3RT1026-3XB40-0LA2
3RT1026-3XF40-0LA2
Size S2
U
A1(+)
A2(-)
32
15
---
---
24
110
B
B
3RT1034-1XB40-0LA2
3RT1034-1XF40-0LA2
C
B
3RT1034-3XB40-0LA2
3RT1034-3XF40-0LA2
40
18.5
---
---
24
110
B
B
3RT1035-1XB40-0LA2
3RT1035-1XF40-0LA2
B
B
3RT1035-3XB40-0LA2
3RT1035-3XF40-0LA2
50
22
---
---
24
110
B
B
3RT1036-1XB40-0LA2
3RT1036-1XF40-0LA2
B
B
3RT1036-3XB40-0LA2
3RT1036-3XF40-0LA2
A1(+)
A2(-)
Size S3
65
30
---
---
24
110
B
B
3RT1044-1XB40-0LA2
3RT1044-1XF40-0LA2
B
B
3RT1044-3XB40-0LA2
3RT1044-3XF40-0LA2
80
37
---
---
24
110
B
B
3RT1045-1XB40-0LA2
3RT1045-1XF40-0LA2
B
B
3RT1045-3XB40-0LA2
3RT1045-3XF40-0LA2
95
45
---
---
24
110
B
B
3RT1046-1XB40-0LA2
3RT1046-1XF40-0LA2
B
B
3RT1046-3XB40-0LA2
3RT1046-3XF40-0LA2
1)
4/16
Siemens IC 10 AO 2014
Siemens AG 2014
Price groups
PG 41A, 41B, 41H
5/3
5/10
5/11
5/13
Introduction
Contactor relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
SIRIUS 3RH14 latched contactor relays,
4-pole
Coupling contactors
SIRIUS 3RH11 coupling contactors
for switching auxiliary circuits,
4-pole
Contactors with extended
operating range 0.7 ... 1.25 Us
for railway applications
SIRIUS 3RH11 contactor relays
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
5/2
Siemens AG 2014
Overview
The advantages at a glance
Size
Type
S00
3RH11
S00
3RH12
Article No.
Page
3RH11
5/5, 5/6
3RH12
5/5, 5/6
3RH14
5/10
4-pole
8-pole
4-pole, latched
Coupling contactors
3RH11
5/11
Contactor relays
for railway applications
3RH11
5/13
3RH1911
5/7
Lateral
3RH1911
Chapter 3
On front
3RT1916
Chapter 3
OFF-delay devices
3RT1916
5/9
Surge suppressors
On front
3RT1916
5/8
On front
3RT1916
5/8
Connection methods
The contactor relays are available with screw terminals
(box terminals) or with spring-type terminals.
Screw terminals
Spring-type terminals
The terminals are indicated in the corresponding
tables by the symbols shown on orange backgrounds.
5/2
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
Overview
Contactor relays and coupling contactors,
size S00, with accessories
3
4
12
5
1
6
13
2
9
14
10
11
16
Contactor relay
Coupling contactor for auxiliary circuits
Solid-state timing relay block, with ON-delay
Solid-state timing relay block, with OFF-delay
5 Auxiliary switch block, with solid-state time-delay
(versions: ON or OFF-delay)
6 1-pole auxiliary switch block, cable entry from above
7 2-pole auxiliary switch block, cable entry from above
8 1-pole auxiliary switch block, cable entry from below
9 2-pole auxiliary switch block, cable entry from below
1
2
3
4
4
10
11
12
13
14
15
16
NSB0_00066a
15
Siemens IC 10 AO 2014
5/3
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
Standards
The 3RH1 contactor relays can be expanded by up to four contacts by the addition of snap-on auxiliary switch blocks.
The auxiliary switch block can easily be snapped onto the front
of the contactors. The auxiliary switch block has a centrally positioned release lever for disassembly.
The 3RH1 contactor relays are suitable for use in any climate.
They are finger-safe according to EN 50274.
The 3RH1 contactor relays have screw terminals or spring-type
terminals. The basic unit contains four contacts with terminal
designations according to EN 50011.
Contact reliability
High contact stability at low voltages and currents, suitable for
solid-state circuits with currents 1 mA at a voltage of 17 V.
Surge suppression
RC elements, varistors, diodes or diode assemblies (combination of a diode and a Zener diode) can be plugged onto all contactor relays from the front for damping opening surges in the
coil. The plug-in direction is determined by a coding device.
Note:
The OFF-delay of the NO contact and the ON-delay of the
NC contact are increased if the contactor coils are attenuated
against voltage peaks (noise suppression diode 6 to 10 times;
diode assembly 2 to 6 times, varistor +2 to 5 ms).
Accessories
The accessories for the 3RT1 contactors in size S00 can also be
used for the 3RH1 contactor relays (see pages 5/8 and 5/9, and
Chapter 3).
3RH
1st generation
1
@
No significance (0)
Special version
3RH
Example
Note:
The article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.
5/4
Siemens IC 10 AO 2014
For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
3RH11. .-2B.40
3RH12. .-1B.40
Article No.
NO
NC
3RH12. .-2B.40
DT Screw terminals
DT Spring-type
terminals
Price
per PU
Article No.
3RH11. .-1B.40
Price
per PU
V AC
13 23 33 43
A1(+)
A2()
14 24 34 44
13 21 33 43
A1(+)
A2()
14 22 34 44
13 21 31 43
14 22 32 44
40E
--
24
110
230
}
}
}
3RH1140-1AB00
3RH1140-1AF00
3RH1140-1AP00
}
}
}
3RH1140-2AB00
3RH1140-2AF00
3RH1140-2AP00
31E
24
110
230
}
}
}
3RH1131-1AB00
3RH1131-1AF00
3RH1131-1AP00
}
}
}
3RH1131-2AB00
3RH1131-2AF00
3RH1131-2AP00
22E
24
110
230
}
}
}
3RH1122-1AB00
3RH1122-1AF00
3RH1122-1AP00
}
}
}
3RH1122-2AB00
3RH1122-2AF00
3RH1122-2AP00
A1(+) 13 23 33 43 51 61 71 81
A2() 14 24 34 44 54 62 72 84
A2() 14 24 34 44 52 62 72 82
6
1)
44E
230
3RH1244-1AP00
3RH1244-2AP00
62E
230
3RH1262-1AP00
3RH1262-2AP00
Siemens IC 10 AO 2014
5/5
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
DC operation
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A
Size S00
3RH11. .-1B.40
3RH11. .-2B.40
V DC
3RH12. .-1B.40
Article No.
NO
NC
3RH12. .-2B.40
DT Screw terminals
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
13 23 33 43
A1(+)
A2()
14 24 34 44
13 21 33 43
A1(+)
A2()
14 22 34 44
13 21 31 43
14 22 32 44
40E
--
24
220
}
}
3RH1140-1BB40
3RH1140-1BM40
}
B
3RH1140-2BB40
3RH1140-2BM40
31E
24
220
}
}
3RH1131-1BB40
3RH1131-1BM40
}
B
3RH1131-2BB40
3RH1131-2BM40
22E
24
220
}
}
3RH1122-1BB40
3RH1122-1BM40
}
B
3RH1122-2BB40
3RH1122-2BM40
A1(+) 13 23 33 43 51 61 71 81
A2() 14 24 34 44 54 62 72 84
A2() 14 24 34 44 52 62 72 82
44E
24
3RH1244-1BB40
3RH1244-2BB40
62E
24
3RH1262-1BB40
3RH1262-2BB40
5/6
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
Options
Rated control supply voltages
(change of 10th and 11th digit of the Article No.)
Contactor type
Rated control supply
voltage Us
3RH11
Contactor type
Rated control supply
voltage Us
AC operation
3RH11
DC operation
60 Hz
12 V DC
24 V DC
42 V DC
A4
B4
D4
24 V AC
42 V AC
48 V AC
----
B0
D0
H0
48 V DC
60 V DC
110 V DC
W4
E4
F4
110 V AC
220 V AC
230 V AC
----
F0
N2
P0
125 V DC
220 V DC
230 V DC
G4
M4
P4
400 V AC
--
V0
50 Hz
60 Hz
110 V AC
220 V AC
120 V AC
240 V AC
K6
P6
60 Hz
100 V AC
200 V AC
400 V AC
110 V AC
220 V AC
440 V AC
G6
N6
R6
1)
Accessories
The auxiliary switch blocks according to EN 50011 listed here
should preferably used for 3RH1 contactor relays.
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41B
3RH1911-2GA22
3RH1911-1GA22
For contactor
relays
Contactor relays
with AS block
Auxiliary contacts
Ident. No.
Version
DT Screw terminals
Article No.
Type
NO
DT Spring-type
terminals
Price
per PU
Article No.
Price
per PU
NC
80E
--
53 63 73 83
71E
53 61 73 83
62E
53 61 71 83
53E
53 61 71 81
44E
--
42)
51 61 71 81
3RH1911-1GA40
3RH1911-2GA40
3RH1911-1GA31
3RH1911-2GA31
3RH1911-1GA22
3RH1911-2GA22
3RH1911-1GA13
3RH1911-2GA13
3RH1911-1GA04
3RH1911-2GA04
54 64 74 84
54 62 74 84
54 62 72 84
54 62 72 82
52 62 72 82
Siemens IC 10 AO 2014
5/7
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
The following accessory parts are accessories for
3RT1 contactors in size S00 which are also entirely suitable for
3RH1 contactor relays.
For
contactors
Version
Type
Power
DT Article No.2)
consumption
AC operation DC operation of LED
at Us
Rated control supply
voltage Us1)
V AC
Price
per PU
PU
PS*
(UNIT,
SET, M)
PG
V DC
Varistor
24 ... 48
48 ... 127
127 ... 240
--
3RH1.
Noise
-suppression -diodes
--
12 ... 24
24 ... 70
70 ... 150
150 ... 250
10 ... 120
20 ... 470
50 ... 700
160 ... 950
}
}
}
A
3RT1916-1JJ00
3RT1916-1JK00
3RT1916-1JL00
3RT1916-1JP00
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
24 ... 70
50 ... 150
150 ... 250
20 ... 470
50 ... 700
160 ... 950
}
}
}
3RT1916-1LM00
3RT1916-1LN00
3RT1916-1LP00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
PU
(UNIT,
SET,
M)
PS*
PG
3RT1916-1L.00
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 or 5 units "-Z" and order code "X90" must be added to the
Article No.
For
contactors
Version
DT Article No.2)
Price
per PU
AC operation DC operation
Type
V AC
V DC
Varistor
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
A
}
A
3RT1916-1BB00
3RT1916-1BC00
3RT1916-1BD00
3RT1916-1BE00
3RT1916-1BF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RH1
RC elements
24 ... 48
48 ... 127
127 ... 240
240 ... 400
400 ... 600
24 ... 70
70 ... 150
150 ... 250
---
}
}
}
}
}
3RT1916-1CB00
3RT1916-1CC00
3RT1916-1CD00
3RT1916-1CE00
3RT1916-1CF00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
3RH1
12 ... 250
3RT1916-1DG00
1 unit
41B
3RH1
Diode assemblies
-(diode and Zener diode) for
DC operation
12 ... 250
3RT1916-1EH00
1 unit
41B
PU
(UNIT,
SET,
M)
PS*
PG
1 unit
41B
3RT1916-1DG00
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 or 5 units "-Z" and order code "X90" must be added to the
Article No.
For
contactors
Version
DT Article No.1)
Price
per PU
Type
3RT1916-1GA00
3RT1916-1GA00
1)
For packs of 10 units, the Article No. must be supplemented with "-Z" and
the order code "X90".
5/8
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Relays
SIRIUS 3RH1 contactor relays,
4- and 8-pole
For contactors
Type
DT Screw terminals
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
OFF-delay devices
For contactor relays with DC operation
110 AC/DC
S00: 130
non-adjustable
3RT1916-2BK01
1 unit
41H
3RH1. . .-1BM40
220/230 AC/DC
S00: 600
non-adjustable
3RT1916-2BL01
1 unit
41H
3RH1. . .-1BB40
24 DC
S00: 250
non-adjustable
3RT1916-2BE01
1 unit
41H
For contactors
Version
DT Article No.
PU
(UNIT,
SET,
M)
PS*
PG
3RH1.
3RK1903-0CA00
1 unit
42D
3RH111)
Sealable covers
for preventing manual operation
3RT1916-4MA10
5 units
41B
3RT1916-2B.01
Price
per PU
Type
Control kit
3RK1903-0CA00
Sealable covers
3RT1916-4MA10
1)
Not for contactor relays with auxiliary switch block mounted onto the front.
Version
DT Spring-type terminals
Article No.
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
3RT1916-4JA02
1 20 units
41B
3RA2908-1A
41B
1 unit
3RA2908-1A
Siemens IC 10 AO 2014
5/9
Siemens AG 2014
Contactor Relays
SIRIUS 3RH14 latched contactor relays,
4-pole
Overview
Standards
Control circuit
The contactor coil and the coil of the release solenoid are both
designed for uninterrupted duty.
Auxiliary switches
The number of auxiliary contacts can be extended by means of
auxiliary switch blocks on the front (up to four contacts).
The contactor relay can also be switched on and released manually. For minimum actuating times, see "Reference Manual for
Switching Devices Contactors and Contactor Assemblies".
3RH1422-1A. . 0
Rated operational
current
Ie/AC-15/AC-14
at 230 V
Contacts
DT Screw terminals
Article No.
NO
NC
PU
(UNIT,
SET,
M)
PS*
PG
Price
per PU
For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, Ident. No. 40E
E1(+) A1+
( ) 13 23 33 43
E1(+) A1(+) 13 21 33 43
E1(+) A1(+) 13 21 31 43
E2(-) A2(-) 14 24 34 44
E2() A2() 14 22 34 44
E2() A2() 14 22 32 44
AC operation
AC 50/60 Hz1)
6
40E
--
24
42
110
230
B
B
B
A
3RH1440-1AB00
3RH1440-1AD00
3RH1440-1AF00
3RH1440-1AP00
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41A
41A
41A
41A
31E
24
42
110
230
B
B
B
B
3RH1431-1AB00
3RH1431-1AD00
3RH1431-1AF00
3RH1431-1AP00
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41A
41A
41A
41A
22E
24
42
110
230
B
B
B
}
3RH1422-1AB00
3RH1422-1AD00
3RH1422-1AF00
3RH1422-1AP00
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41A
41A
41A
41A
40E
--
24
110
220
}
B
B
3RH1440-1BB40
3RH1440-1BF40
3RH1440-1BM40
1
1
1
1 unit
1 unit
1 unit
41A
41A
41A
31E
24
110
220
B
B
B
3RH1431-1BB40
3RH1431-1BF40
3RH1431-1BM40
1
1
1
1 unit
1 unit
1 unit
41A
41A
41A
22E
24
110
220
}
B
B
3RH1422-1BB40
3RH1422-1BF40
3RH1422-1BM40
1
1
1
1 unit
1 unit
1 unit
41A
41A
41A
DC operation
DC
6
1)
5/10
Siemens IC 10 AO 2014
Siemens AG 2014
Contactor Relays
Coupling Contactors
SIRIUS 3RH11 coupling contactors
for switching auxiliary circuits, 4-pole
Overview
The 3RH11 coupling contactors cannot be extended with auxiliary switch blocks.
DC operation
IEC 60947-1, EN 60947-1,
IEC 60947-5-1, EN 60947-5-1
DC operation
Low power consumption
Extended operating range of the solenoid coil
Integrated coil circuit
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A
3R11. .-1.B40
Rated operational current
Ie/AC-15/AC-14
at 230 V
Auxiliary contacts
Ident. No. acc. to
EN 50011
DT Spring-type terminals
Version
Article No.
NO
3RH11. .-2.B40
DT Screw terminals
Price
per PU
Article No.
Price
per PU
NC
13 23 33 43
13 21 33 43
A1(+)
A2()
14 24 34 44
13 21 31 43
A2()
14 22 34 44
14 22 32 44
Rated control supply voltage Us = 24 V DC, coil operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.3 W at 24 V
6
40E
31E
22E
4
3
2
-1
2
}
}
}
3RH1140-1HB40
3RH1131-1HB40
3RH1122-1HB40
B
B
B
3RH1140-2HB40
3RH1131-2HB40
3RH1122-2HB40
3RH1140-1MB40-0KT0
3RH1131-1MB40-0KT0
3RH1122-1MB40-0KT0
B
B
B
3RH1140-2MB40-0KT0
3RH1131-2MB40-0KT0
3RH1122-2MB40-0KT0
40E
31E
22E
4
3
2
-1
2
B
B
A
Siemens IC 10 AO 2014
5/11
Siemens AG 2014
Contactor Relays
Coupling Contactors
SIRIUS 3RH11 coupling contactors
for switching auxiliary circuits, 4-pole
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41A
3R11. .-1.B40
Auxiliary contacts
Ident. No. acc. to
EN 50011
DT Spring-type terminals
Version
Article No.
NO
3RH11. .-2.B40
DT Screw terminals
Price
per PU
Article No.
Price
per PU
NC
13 23 33 43
13 21 33 43
A1(+)
A2()
14 24 34 44
13 21 31 43
A2()
14 22 34 44
14 22 32 44
Rated control supply voltage Us = 24 V DC, coil operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.3 W at 24 V
6
40E
31E
22E
4
3
2
-1
2
}
}
}
3RH1140-1JB40
3RH1131-1JB40
3RH1122-1JB40
B
}
B
3RH1140-2JB40
3RH1131-2JB40
3RH1122-2JB40
3RH1140-1VB40
3RH1131-1VB40
3RH1122-1VB40
B
B
B
3RH1140-2VB40
3RH1131-2VB40
3RH1122-2VB40
40E
31E
22E
4
3
2
-1
2
B
A
B
13 23 33 43
A1(+)
A2()
14 24 34 44
13 21 33 43
14 22 34 44
13 21 31 43
14 22 32 44
Rated control supply voltage Us = 24 V DC, coil operating range 0.7 to 1.25 x Us
Power consumption of the solenoid coils 2.3 W at 24 V
6
40E
31E
22E
4
3
2
-1
2
}
}
}
3RH1140-1KB40
3RH1131-1KB40
3RH1122-1KB40
B
}
}
3RH1140-2KB40
3RH1131-2KB40
3RH1122-2KB40
3RH1140-1WB40
3RH1131-1WB40
3RH1122-1WB40
B
B
B
3RH1140-2WB40
3RH1131-2WB40
3RH1122-2WB40
40E
31E
22E
5/12
Siemens IC 10 AO 2014
4
3
2
-1
2
B
A
A
Siemens AG 2014
Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
SIRIUS 3RH11 contactor relays
Overview
DC operation
Ambient temperature
L+
L-
The permissible ambient temperature for operation of the contactor relays (across the full coil operating range) is -40 to
+70 C.
S1
Application
For operation in installations which are subject both to considerable variations in the control voltage and to high ambient temperatures, e. g. railway applications under extreme climatic conditions, rolling mills, etc.
Also for control supply voltages with battery buffering to extend
the operating time in the event of battery charge failure.
E1+
K1
K1
13 23 31
A2-
14 24 32
NSB0_00560a
Circuit diagram
Siemens IC 10 AO 2014
5/13
Siemens AG 2014
Contactor Relays
Contactors with Extended Operating Range 0.7 ... 1.25 x Us for Railway Applications
SIRIUS 3RH11 contactor relays
3RH1122-2K.40
Rated operational current
Ie/AC-15/AC-14
Tu: 70 C at
230 V
400 V
500 V
Contacts
690 V
3RH1122-2K.40-0LA0
DT Spring-type terminals
PS*
PG
Version
Article No.
PU
(UNIT,
SET, M)
NO
NC
Price
per PU
V DC
For screw fixing and snap-on mounting onto TH 35 standard mounting rail
Size S00
With conventional coil, fitted with varistor
Terminal designations according to EN 50011
2 NO + 2 NC, Ident. No. 22E
A1(+)
A2()
13 21 31 43
14 22 32 44
21)
24
110
}
A
3RH1122-2KB40
3RH1122-2KF40
1
1
1 unit
1 unit
41A
41A
12)
24
110
A
A
3RH1122-2KB40-0LA0
3RH1122-2KF40-0LA0
1
1
1 unit
1 unit
41A
41A
A2()
6
1)
2)
13 23 31
14 24 32
5/14
Siemens IC 10 AO 2014
Siemens AG 2014
Protection Equipment
Price groups
PG 14O, 41B, 41E, 41F, 41G, 41H, 41J
7/5
7/8
7/11
7/12
7/13
7/14
7/15
7/16
7/17
7/20
7/23
7/25
7/29
7/32
7/36
7/40
7/45
7/47
7/52
7/54
7/59
7/60
Introduction
SIRIUS 3RV1 motor starter protectors/
circuit breakers up to 100 A
General data
For motor protection
For motor protection
with overload relay function
For starter combinations
For transformer protection
For fuse monitoring
For system protection according to
UL 489/CSA C22.2 No.5
For distance protection
Accessories
- Mountable accessories
- Busbar accessories
- Rotary operating mechanisms
- Mounting accessories
- Enclosures and front plates
3RV19 infeed systems
Overload relays
General data
SIRIUS 3RU1 thermal overload relays
3RU11 up to 100 A
for standard applications
Accessories
SIRIUS 3RB2 solid-state overload relays
3RB20, 3RB21 up to 630 A
for standard applications
Accessories for 3RB20, 3RB21
3RB22, 3RB23 up to 630 A
for High-Feature applications
Current measuring modules for
3RB22, 3RB23
Accessories for 3RB22, 3RB23
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
7/2
Siemens AG 2014
Protection Equipment
Introduction
Overview
Type
3RV10
3RV11
3RV13
3RV14
3RV16
3RV16
3RV17
Applications
System protection
1)
1)
--
--
--
--
Motor protection
--
--
--
--
--
--
--
--
--
--
--
---
Starter combinations
--
--
--
--
--
Transformer protection
--
--
--
--
--
--
Fuse monitoring
--
--
--
--
--
--
--
--
--
--
--
--
Size
S0, S2, S3
S0, S2
S00
S00
S3
A
A
A
A
Up to 12
Up to 25
Up to 50
Up to 100
-Up to 25
Up to 50
Up to 100
-Up to 25
Up to 50
Up to 100
-Up to 20
Up to 40
--
0.2
----
Up to 3
----
---Up to 70
690 AC2)
690 AC2)
690 AC2)
690 AC2)
690 AC2)
400 AC
690 AC
Rated frequency
Hz 50/60
Rated current In
Size S00
Size S0
Size S2
Size S3
Trip class
Thermal overload releases
A
A
Electronic release
A multiple of the rated current
Short-circuit breaking capacity Icu
at 400 V AC
50/60
50/60
50/60
50/60
162/3 ... 60
50/60
CLASS 10, 20
CLASS 10
--
CLASS 10
--
--
--
None3)
0.2
1.4 ... 3
10 ... 70
nonadjustable
13 times
13 times
13 times
20 times
6 times
4 ... 7 times
13 times
50/100
50/100
50/100
100
50
4)
7/11
7/12
7/13
7/14, 7/16
7/16
7/15
kA 50/100
7/8 up to 7/10
Pages
Accessories
For sizes
S00 S0 S2 S3 S0 S2 S3
S0 S2 S3
S0 S2
S00
S00
S3
Auxiliary switches
5)
Signaling switches
--
--
--
--
Undervoltage releases
--
--
--
Shunt releases
--
--
--
Isolator modules
--
--
--
--
--
--
--
Insulated three-phase
busbar system
--
--
--
--
--
Busbar adapters
--
--
--
--
--
--
--
Link modules
--
--
--
--
--
--
--
--
--
--
--
Front plates
--
Infeed system
--
--
--
--
--
--
--
--
--
--
Pages
2)
7/2
Siemens IC 10 AO 2014
---
--
--
--
--
--
3)
4)
According to UL 489
- at 480 Y/277 V AC: 65 kA;
- at 480 V AC: 65 kA.
5)
Siemens AG 2014
Protection Equipment
Introduction
Type
3RV10
3RV13
--
Starter combinations
--
Switching capacity
3RV1063
3RV1073
3RV1083
3RV1353
3RV1363
3RV1373
3RV1383
3RV1364
3RV1374
400
630
1 ... 32
400, 630
630, 800
400
120
100
200
200
Size
Rated current In
690 AC
690 AC
Hz 50/60
50/60
--1)
40 ... 100
up to
252 ... 630
None1)
Short-circuit breaking
capacityIcu at 400 V AC
kA 120
Trip unit
Trip class
Electronic release
A multiple of the rated
current
Increased switching
capacity
120
100
85
120
TU 1:
1 ... 12.5 A;
TU 2:
20 A, 32 A
TU 3
3RV1083
3RV1353
3RV1363
3RV1373
3RV1383
3RV1364
3RV1374
TU 4
Accessories1)
For molded case motor
starter protectors
3RV1063
3RV1073
Auxiliary switches
Undervoltage releases
Shunt releases
--
--
Connection methods
Extended terminals
on the front
Cable terminals
on the front
Rear terminals
2)
Siemens IC 10 AO 2014
7/3
Siemens AG 2014
Protection Equipment
Introduction
Type
3RU11
3RB20
3RB21
3RB22, 3RB23
System protection
1)
1)
1)
1)
Motor protection
Applications
--
--
Direct current
--
--
--
Size of contactor
A
A
Up to 12
Up to 25
Up to 12
Up to 25
Up to 12
Up to 25
Up to 25
Up to 25
Size S2
Size S3
A
A
Up to 50
Up to 100
Up to 50
Up to 100
Up to 50
Up to 100
Up to 100
Up to 100
Size S6
Size S10/S12,
size 14 (3TF68/3TF69)
A
A
---
Up to 200
Up to 630
Up to 200
Up to 630
Up to 200
Up to 630
Rated frequency
Hz
50/60
50/60
50/60
50/60
CLASS 10
CLASS 10, 20
--
--
--
--
0.3 ... 3
up to
63 ... 630
kW 0.04
to
kW 45
7/49, 7/50
7/51
Trip class
Thermal overload releases
Pages
Accessories
For sizes
S00 S0 S2 S3
5)
5)
5)
5)
5)
5)
5)
5)
5)
5)
5)
5)
5)
5)
Mechanical RESET
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Terminal covers
--
--
--
--
--
--
--
--
--
--
--
Pages
7/45, 7/46
7/52, 7/53
The units are responsible in the main circuit for overload protection of the
assigned electrical loads (e.g. motors), feeder cable and other switching
and protection devices in the respective load feeder.
2)
3)
4)
5)
7/4
Siemens IC 10 AO 2014
7/52, 7/53
7/60, 7/61
Siemens AG 2014
Overview
The following illustration shows our 3RV1 motor starter protectors/circuit breakers with the accessories which can be mounted
for the various sizes, see also "Introduction" "Overview" on
page 7/2.
4
2
1
6.1
Motor starter protectors/circuit breakers, sizes S0, S2 or S3, with mountable accessories
8
2
4
Mountable accessories
6.1
6.2
7
8
NSB0_01426c
6.2
For sizes
S00
S0 ... S3
S0 ... S3
S0, S2
Siemens IC 10 AO 2014
7/5
Siemens AG 2014
Connection methods
The SIRIUS 3RV1 motor starter protectors/circuit breakers can
be supplied with screw terminals and spring-type terminals.
Screw terminals
Spring-type terminals
3RV
1
@
Size
Switching capacity
Setting range for overload release
Connection methods
Example
Note:
The Article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.
7/6
Siemens IC 10 AO 2014
For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.
Siemens AG 2014
Application
Operating conditions
Possible uses
Siemens IC 10 AO 2014
7/7
Siemens AG 2014
3RV1011-0JA10
Rated
current
Suitable for
three-phase
motors1)
with P
3RV1021-0JA10
Instantaneous
overcurrent
releases
Short-circuit
breaking capacity
at 400 V AC
3RV1011-1EA20
DT
Icu
In
A
DT
Screw terminals
Article No.
Price
per PU
Spring-type
terminals
Article No.
kW
kA
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
2.1
2.6
3.3
4.2
100
100
100
100
}
}
}
}
3RV1011-0AA10
3RV1011-0BA10
3RV1011-0CA10
3RV1011-0DA10
}
}
}
}
3RV1011-0AA20
3RV1011-0BA20
3RV1011-0CA20
3RV1011-0DA20
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
5.2
6.5
8.2
10
100
100
100
100
}
}
}
}
3RV1011-0EA10
3RV1011-0FA10
3RV1011-0GA10
3RV1011-0HA10
}
}
}
}
3RV1011-0EA20
3RV1011-0FA20
3RV1011-0GA20
3RV1011-0HA20
1
1.25
1.6
2
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
100
100
100
100
}
}
}
}
3RV1011-0JA10
3RV1011-0KA10
3RV1011-1AA10
3RV1011-1BA10
}
}
}
}
3RV1011-0JA20
3RV1011-0KA20
3RV1011-1AA20
3RV1011-1BA20
2.5
3.2
4
5
0.75
1.1
1.5
1.5
33
42
52
65
100
100
100
100
}
}
}
}
3RV1011-1CA10
3RV1011-1DA10
3RV1011-1EA10
3RV1011-1FA10
}
}
}
}
3RV1011-1CA20
3RV1011-1DA20
3RV1011-1EA20
3RV1011-1FA20
6.3
8
10
12
2.2
3
4
5.5
82
104
130
156
100
50
50
50
}
}
}
}
3RV1011-1GA10
3RV1011-1HA10
3RV1011-1JA10
3RV1011-1KA10
}
}
}
}
3RV1011-1GA20
3RV1011-1HA20
3RV1011-1JA20
3RV1011-1KA20
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
2.1
2.6
3.3
4.2
100
100
100
100
}
}
}
}
3RV1021-0AA10
3RV1021-0BA10
3RV1021-0CA10
3RV1021-0DA10
-----
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
5.2
6.5
8.2
10
100
100
100
100
}
}
}
}
3RV1021-0EA10
3RV1021-0FA10
3RV1021-0GA10
3RV1021-0HA10
-----
1
1.25
1.6
2
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
100
100
100
100
}
}
}
}
3RV1021-0JA10
3RV1021-0KA10
3RV1021-1AA10
3RV1021-1BA10
-----
2.5
3.2
4
5
0.75
1.1
1.5
1.5
33
42
52
65
100
100
100
100
}
}
}
}
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1FA10
-----
6.3
8
10
12.5
2.2
3
4
5.5
82
104
130
163
100
100
100
100
}
}
}
}
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
-----
16
20
22
25
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
208
260
286
325
50
50
50
50
}
}
}
}
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4CA10
3RV1021-4DA10
-----
Price
per PU
Size S00
Size S0
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
Auxiliary switches and other accessories can be ordered separately (see "Mountable accessories" on page 7/17 onwards).
Multi-unit packing and reusable packaging on request.
7/8
Siemens IC 10 AO 2014
Siemens AG 2014
3RV1011-0KA15
with integrated transverse auxiliary switch
Rated
current
Suitable for
three-phase
motors1)
with P
3RV1021-1GA15
with integrated transverse auxiliary switch
Instantaneous
overcurrent
releases
Short-circuit
breaking capacity
at 400 V AC
3RV1011-0GA25
with integrated transverse auxiliary switch
DT
Icu
In
A
DT
Screw terminals
Article No.
Price
per PU
Spring-type
terminals
Article No.
kW
kA
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
2.1
2.6
3.3
4.2
100
100
100
100
}
}
}
}
3RV1011-0AA15
3RV1011-0BA15
3RV1011-0CA15
3RV1011-0DA15
B
B
B
B
3RV1011-0AA25
3RV1011-0BA25
3RV1011-0CA25
3RV1011-0DA25
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
5.2
6.5
8.2
10
100
100
100
100
}
}
}
}
3RV1011-0EA15
3RV1011-0FA15
3RV1011-0GA15
3RV1011-0HA15
B
B
B
B
3RV1011-0EA25
3RV1011-0FA25
3RV1011-0GA25
3RV1011-0HA25
1
1.25
1.6
2
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
100
100
100
100
}
}
}
}
3RV1011-0JA15
3RV1011-0KA15
3RV1011-1AA15
3RV1011-1BA15
B
B
B
B
3RV1011-0JA25
3RV1011-0KA25
3RV1011-1AA25
3RV1011-1BA25
2.5
3.2
4
5
0.75
1.1
1.5
1.5
33
42
52
65
100
100
100
100
}
}
}
}
3RV1011-1CA15
3RV1011-1DA15
3RV1011-1EA15
3RV1011-1FA15
B
B
B
B
3RV1011-1CA25
3RV1011-1DA25
3RV1011-1EA25
3RV1011-1FA25
6.3
8
10
12
2.2
3
4
5.5
82
104
130
156
100
50
50
50
}
}
}
}
3RV1011-1GA15
3RV1011-1HA15
3RV1011-1JA15
3RV1011-1KA15
B
B
B
B
3RV1011-1GA25
3RV1011-1HA25
3RV1011-1JA25
3RV1011-1KA25
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
2.1
2.6
3.3
4.2
100
100
100
100
}
}
}
}
3RV1021-0AA15
3RV1021-0BA15
3RV1021-0CA15
3RV1021-0DA15
-----
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
5.2
6.5
8.2
10
100
100
100
100
}
}
}
}
3RV1021-0EA15
3RV1021-0FA15
3RV1021-0GA15
3RV1021-0HA15
-----
1
1.25
1.6
2
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
100
100
100
100
}
}
}
}
3RV1021-0JA15
3RV1021-0KA15
3RV1021-1AA15
3RV1021-1BA15
-----
2.5
3.2
4
5
0.75
1.1
1.5
1.5
33
42
52
65
100
100
100
100
}
}
}
}
3RV1021-1CA15
3RV1021-1DA15
3RV1021-1EA15
3RV1021-1FA15
-----
6.3
8
10
12.5
2.2
3
4
5.5
82
104
130
163
100
100
100
100
}
}
}
}
3RV1021-1GA15
3RV1021-1HA15
3RV1021-1JA15
3RV1021-1KA15
-----
16
20
22
25
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
208
260
286
325
50
50
50
50
}
}
}
}
3RV1021-4AA15
3RV1021-4BA15
3RV1021-4CA15
3RV1021-4DA15
-----
Price
per PU
Size S00
Size S0
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
Auxiliary switches and other accessories can be ordered separately (see "Mountable accessories" on page 7/17 onwards).
Multi-unit packing and reusable packaging on request.
Siemens IC 10 AO 2014
7/9
Siemens AG 2014
In
Short-circuit
breaking
capacity at
400 V AC
DT
Screw terminals
Article No.
Icu
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
kW
kA
16
20
25
32
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
208
260
325
416
50
50
50
50
}
}
}
}
3RV1031-4AA10
3RV1031-4BA10
3RV1031-4DA10
3RV1031-4EA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
45
50
18.5
22
22
28 ... 40
36 ... 45
40 ... 50
520
585
650
50
50
50
}
}
}
3RV1031-4FA10
3RV1031-4GA10
3RV1031-4HA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
40
50
63
18.5
22
30
28 ... 40
36 ... 50
45 ... 63
520
650
819
50
50
50
}
}
}
3RV1041-4FA10
3RV1041-4HA10
3RV1041-4JA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
57 ... 75
70 ... 90
80 ... 100
975
1 170
1 235
50
50
50
}
}
}
3RV1041-4KA10
3RV1041-4LA10
3RV1041-4MA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
Size S2
3RV1031-4HA10
Size S3
3RV1041-4LA10
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
208
260
325
416
100
100
100
100
}
}
}
}
3RV1042-4AA10
3RV1042-4BA10
3RV1042-4DA10
3RV1042-4EA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
50
63
18.5
22
30
28 ... 40
36 ... 50
45 ... 63
520
650
819
100
100
100
}
}
}
3RV1042-4FA10
3RV1042-4HA10
3RV1042-4JA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
57 ... 75
70 ... 90
80 ... 100
975
1 170
1 235
100
100
100
}
}
}
3RV1042-4KA10
3RV1042-4LA10
3RV1042-4MA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1042-4JA10
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
208
260
325
416
50
50
50
50
A
A
A
A
3RV1031-4AB10
3RV1031-4BB10
3RV1031-4DB10
3RV1031-4EB10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
45
50
18.5
22
22
28 ... 40
36 ... 45
40 ... 50
520
585
650
50
50
50
A
A
A
3RV1031-4FB10
3RV1031-4GB10
3RV1031-4HB10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1031-4AB10
18.5
22
30
28 ... 40
36 ... 50
45 ... 63
520
650
819
100
100
100
A
A
A
3RV1042-4FB10
3RV1042-4HB10
3RV1042-4JB10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
57 ... 75
70 ... 90
80 ... 100
975
1 170
1 235
100
100
100
A
A
A
3RV1042-4KB10
3RV1042-4LB10
3RV1042-4MB10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1042-4KB10
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
Auxiliary switches and other accessories can be ordered separately (see "Mountable accessories" on page 7/17 onwards).
Multi-unit packing and reusable packaging on request.
7/10
Siemens IC 10 AO 2014
Siemens AG 2014
Short-circuit
breaking
capacity at
400 V AC
In
Icu
DT
Screw terminals
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
kW
kA
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
2.1
2.6
3.3
4.2
100
100
100
100
A
A
A
A
3RV1121-0AA10
3RV1121-0BA10
3RV1121-0CA10
3RV1121-0DA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
5.2
6.5
8.2
10
100
100
100
100
A
A
A
A
3RV1121-0EA10
3RV1121-0FA10
3RV1121-0GA10
3RV1121-0HA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
1
1.25
1.6
2
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
100
100
100
100
A
A
A
A
3RV1121-0JA10
3RV1121-0KA10
3RV1121-1AA10
3RV1121-1BA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
2.5
3.2
4
5
0.75
1.1
1.5
1.5
33
42
52
65
100
100
100
100
A
A
A
A
3RV1121-1CA10
3RV1121-1DA10
3RV1121-1EA10
3RV1121-1FA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
6.3
8
10
12.5
2.2
3
4
5.5
82
104
130
163
100
100
100
100
A
A
A
A
3RV1121-1GA10
3RV1121-1HA10
3RV1121-1JA10
3RV1121-1KA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
16
20
22
25
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
208
260
286
325
50
50
50
50
A
A
A
A
3RV1121-4AA10
3RV1121-4BA10
3RV1121-4CA10
3RV1121-4DA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
16
20
25
32
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
208
260
325
416
50
50
50
50
A
A
A
A
3RV1131-4AA10
3RV1131-4BA10
3RV1131-4DA10
3RV1131-4EA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
45
50
18.5
22
22
28 ... 40
36 ... 45
40 ... 50
520
585
650
50
50
50
A
A
A
3RV1131-4FA10
3RV1131-4GA10
3RV1131-4HA10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1121-0KA10
Size S22)
3RV1131-4EA10
3RV1142-4AA10
16
20
25
32
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
208
260
325
416
100
100
100
100
A
A
A
A
3RV1142-4AA10
3RV1142-4BA10
3RV1142-4DA10
3RV1142-4EA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
50
63
18.5
22
30
28 ... 40
36 ... 50
45 ... 63
520
650
819
100
100
100
A
A
A
3RV1142-4FA10
3RV1142-4HA10
3RV1142-4JA10
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
57 ... 75
70 ... 90
80 ... 100
975
1 170
1 235
100
100
100
A
A
A
3RV1142-4KA10
3RV1142-4LA10
3RV1142-4MA10
1
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
Accessories for mounting on the right (for sizes S0 to S3) and 3RV1915
three-phase busbars (for size S0) cannot be used.
1
1
Auxiliary switches and other accessories can be ordered separately (see "Mountable accessories" on page 7/17 onwards).
Siemens IC 10 AO 2014
7/11
Size S02)
Siemens AG 2014
Instantaneous
overcurrent
releases
In
Short-circuit
breaking
capacity at
400 V AC
DT
Screw terminals
Article No.
Icu
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
kW
kA
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
None
None
None
None
2.1
2.6
3.3
4.2
100
100
100
100
A
A
A
A
3RV1321-0AC10
3RV1321-0BC10
3RV1321-0CC10
3RV1321-0DC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
None
None
None
None
5.2
6.5
8.2
10
100
100
100
100
A
A
A
A
3RV1321-0EC10
3RV1321-0FC10
3RV1321-0GC10
3RV1321-0HC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
1
1.25
1.6
2
0.25
0.37
0.55
0.75
None
None
None
None
13
16
21
26
100
100
100
100
A
A
A
A
3RV1321-0JC10
3RV1321-0KC10
3RV1321-1AC10
3RV1321-1BC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
2.5
3.2
4
5
0.75
1.1
1.5
1.5
None
None
None
None
33
42
52
65
100
100
100
100
A
A
A
A
3RV1321-1CC10
3RV1321-1DC10
3RV1321-1EC10
3RV1321-1FC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
6.3
8
10
12.5
2.2
3
4
5.5
None
None
None
None
82
104
130
163
100
100
100
100
A
A
A
A
3RV1321-1GC10
3RV1321-1HC10
3RV1321-1JC10
3RV1321-1KC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
16
20
22
25
7.5
7.5
11
11
None
None
None
None
208
260
286
325
50
50
50
50
A
A
A
A
3RV1321-4AC10
3RV1321-4BC10
3RV1321-4CC10
3RV1321-4DC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
16
20
25
32
7.5
7.5
11
15
None
None
None
None
208
260
325
416
50
50
50
50
A
A
A
A
3RV1331-4AC10
3RV1331-4BC10
3RV1331-4DC10
3RV1331-4EC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
45
50
18.5
22
22
None
None
None
520
585
650
50
50
50
A
A
A
3RV1331-4FC10
3RV1331-4GC10
3RV1331-4HC10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
40
50
63
18.5
22
30
None
None
None
520
650
819
50
50
50
A
A
A
3RV1341-4FC10
3RV1341-4HC10
3RV1341-4JC10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
None
None
None
975
1 170
1 235
50
50
50
A
A
A
3RV1341-4KC10
3RV1341-4LC10
3RV1341-4MC10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
Size S0
3RV1321-0AC10
Size S2
3RV1331-4AC10
Size S3
3RV1341-4JC10
7.5
7.5
11
15
None
None
None
None
208
260
325
416
100
100
100
100
A
A
A
A
3RV1342-4AC10
3RV1342-4BC10
3RV1342-4DC10
3RV1342-4EC10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
50
63
18.5
22
30
None
None
None
520
650
819
100
100
100
A
A
A
3RV1342-4FC10
3RV1342-4HC10
3RV1342-4JC10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
75
90
100
37
45
45
None
None
None
975
1 170
1 235
100
100
100
A
A
A
3RV1342-4KC10
3RV1342-4LC10
3RV1342-4MC10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1342-4JC10
1)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
2)
7/12
Siemens IC 10 AO 2014
Siemens AG 2014
Instantaneous
overcurrent
release
In
Short-circuit
breaking
capacity at
400 V AC
DT
Screw terminals
Article No.
Icu
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
kA
0.16
0.2
0.25
0.32
3.3
4.2
5.2
6.5
100
100
100
100
}
}
}
}
3RV1421-0AA10
3RV1421-0BA10
3RV1421-0CA10
3RV1421-0DA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
0.4
0.5
0.63
0.8
8.2
10
13
16
100
100
100
100
}
}
}
}
3RV1421-0EA10
3RV1421-0FA10
3RV1421-0GA10
3RV1421-0HA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
1
1.25
1.6
2
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
21
26
33
42
100
100
100
100
}
}
}
}
3RV1421-0JA10
3RV1421-0KA10
3RV1421-1AA10
3RV1421-1BA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
2.5
3.2
4
5
52
65
82
104
100
100
100
100
}
}
}
}
3RV1421-1CA10
3RV1421-1DA10
3RV1421-1EA10
3RV1421-1FA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
6.3
8
10
12.5
130
163
208
260
100
100
100
100
}
}
}
}
3RV1421-1GA10
3RV1421-1HA10
3RV1421-1JA10
3RV1421-1KA10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
16
20
11 ... 16
14 ... 20
286
325
50
50
}
}
3RV1421-4AA10
3RV1421-4BA10
1
1
1 unit
1 unit
41E
41E
16
20
25
32
40
11 ... 16
14 ... 20
18 ... 25
22 ... 32
28 ... 40
325
416
520
660
836
50
50
50
50
50
}
}
}
}
}
3RV1431-4AA10
3RV1431-4BA10
3RV1431-4DA10
3RV1431-4EA10
3RV1431-4FA10
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
41E
3RV1421-0KA10
Size S2
3RV1431-4DA10
Auxiliary switches and other accessories can be ordered separately (see "Mountable accessories" on page 7/17 onwards).
Siemens IC 10 AO 2014
7/13
Size S0
Siemens AG 2014
Thermal
overload
releases
Instantaneous
overcurrent
release
In
Short-circuit
breaking
capacity at
400 V AC
DT
Article No.
Icu
kA
0.2
0.2
1.2
100
Screw terminals
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41E
Price
per PU
Size S00
}
3RV1611-0BD10
3RV1611-0BD10
Note:
The auxiliary switch required for signaling must be ordered
separately.
Accessories
Version
Contacts
DT
Screw terminals
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
1 NO + 1 NC
3RV1901-1E
1 unit
41E
1 NO + 1 NC
3RV1901-1A
1 unit
41E
3RV1901-1E
3RV1901-1A
7/14
Siemens IC 10 AO 2014
Siemens AG 2014
Instantaneous
overcurrent
release
In1)
Short-circuit breaking
capacity at
DT
Screw terminals
Ibc
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
kA
kA
10
15
10
15
150
225
65
65
65
65
B
B
3RV1742-5AD10
3RV1742-5BD10
1
1
1 unit
1 unit
41E
41E
20
25
30
35
20
25
30
35
260
325
390
455
65
65
65
65
65
65
65
--
B
B
B
B
3RV1742-5CD10
3RV1742-5DD10
3RV1742-5ED10
3RV1742-5FD10
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
40
45
50
40
45
50
520
585
650
65
65
65
----
B
B
B
3RV1742-5GD10
3RV1742-5HD10
3RV1742-5JD10
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
60
3RV1742-5FD10 70
60
70
780
910
65
65
---
B
B
3RV1742-5LD10
3RV1742-5QD10
1
1
1 unit
1 unit
41E
41E
1)
2)
Size S3
Siemens IC 10 AO 2014
7/15
Siemens AG 2014
Thermal
overload
releases
Instantaneous
overcurrent
release
Auxiliary
switch
integrated
in the motor
starter
protector,
transverse
Short-circuit
breaking
capacity at
400 V AC
DT Screw terminals
PU
(UNIT,
SET, M)
PS*
PG
3RV1611-1AG14
3RV1611-1CG14
3RV1611-1DG14
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
DT Screw terminals
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41E
Article No.
Icu
In
1.4
2.5
3
1.4
2.5
3
6
10.5
20
Price
per PU
kA
Size S00
1 CO
1 CO
1 CO
50
50
50
B
}
}
3RV1611-1.G14
Accessories
Version
Contacts
Article No.
Price
per PU
1 NO + 1 NC
3RV1901-1A
3RV1901-1A
More information
Conversion of 3VU13 to 3RV1 voltage transformer circuit breakers
The 3VU13 voltage transformer circuit breakers previously
available have been discontinued. The 3RV1 voltage transformer circuit breakers are offered as replacement types.
Previous type
Replacement type
3VU1311-6HR00
3RV1611-1CG14
3VU1321-6HR00
3RV1611-1CG14 + 3RV1901-1A
3VU1311-6JR00
3RV1611-1DG14
7/16
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Mounting location and function
The 3RV1 motor starter protectors/circuit breakers have three
main contact elements. In order to achieve maximum flexibility,
auxiliary switches, signaling switches, auxiliary releases and isolator modules can be supplied separately.
Front side
One of the three lateral auxiliary switches can be mounted on the left side
per motor starter protector/circuit breaker. The contacts of the auxiliary
switch close and open together with the main contacts of the motor starter
protector/circuit breaker.
Notes:
1 NO + 1 NC
A maximum of 4 auxiliary contacts with
auxiliary switches can be attached to each or
2 NO
motor starter protector/circuit breaker.
or
Auxiliary switches (2 contacts) and
2 NC
signaling switches can be mounted
Lateral auxiliary switches
separately or together.
(4 contacts)
The signaling switch cannot be used for the
2 NO + 2 NC
3RV1742 circuit breakers.
One lateral auxiliary switch with four contacts can be mounted on the left
side per motor starter protector/circuit breaker. The contacts of the auxiliary
switch close and open together with the main contacts of the motor starter
protector/circuit breaker.
Tripping 1 NO + 1 NC
Short circuit 1 NO + 1 NC
Right-hand side
Auxiliary releases
Notes:
Shunt releases
or
Undervoltage releases
Trips the motor starter protector/circuit breaker when the voltage is interrupted and prevents the motor from being restarted accidentally when the
voltage is restored. Used for remote-controlled tripping of the motor starter
protector/circuit breaker.
Particularly suitable for EMERGENCY-STOP disconnection by way of corresponding EMERGENCY-STOP pushbuttons according to DIN EN 60204-1.
or
Undervoltage releases with
leading auxiliary contacts 2 NO
Function and use as for the undervoltage release without leading auxiliary
contacts, but with the following additional function: the auxiliary contacts will
open in switch position OFF to deenergize the coil of the undervoltage
release, thus interrupting energy consumption. In the "tripped" position,
these auxiliary contacts are not guaranteed to open. The leading contacts
permit the motor starter protector/circuit breaker to reclose.
The overall width of the auxiliary release is 18 mm.
Top
Notes:
Isolator modules can be mounted to the upper terminal end of motor starter
protector of sizes S0 and S2.
The supply cable is connected to the motor starter protector through the
isolator module.
The plug can only be unplugged when the motor starter protector is open
and isolates all 3 poles of the motor starter protector from the network. The
shock-protected isolation point is clearly visible and secured with a padlock
to prevent reinsertion of the plug.
Siemens IC 10 AO 2014
7/17
Siemens AG 2014
Contacts
DT
Screw terminals
Article No.
Size
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
Auxiliary switches1)
3RV1901-1E
3RV1901-1G
1 CO
S00, S0, S2, S3
1 NO + 1 NC
2 NO
}
}
}
3RV1901-1D
3RV1901-1E
3RV1901-1F
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
Electronic compatible
transverse auxiliary switches
With screw terminals,
front mountable,
for operation in dusty atmosphere
and in electronic circuits with low
operating currents
1 CO
3RV1901-1G
1 unit
41E
--
3RV1901-0H
1 10 units
41E
}
}
}
A
3RV1901-1A
3RV1901-1B
3RV1901-1C
3RV1901-1J
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
DT
Spring-type
terminals
PU
(UNIT,
SET, M)
PS*
PG
3RV1901-0H
3RV1901-1A
3RV1901-1J
1)
Each motor starter protector can be fitted with one transverse and one
lateral auxiliary switch. The lateral auxiliary switch with 2 NO + 2 NC is
used without a transverse auxiliary switch. Transverse auxiliary switches
must not be used for the 3RV1742 circuit breakers.
Version
Contacts
Article No.
Size
Price
per PU
Auxiliary switches1)
Transverse auxiliary switches
3RV1901-2E
}
}
3RV1901-2E
3RV1901-2F
1
1
1 unit
1 unit
41E
41E
}
}
}
3RV1901-2A
3RV1901-2B
3RV1901-2C
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1901-2A
1)
Each motor starter protector can be fitted with one transverse and one
lateral auxiliary switch. Transverse auxiliary switches must not be used for
the 3RV1742 circuit breakers.
7/18
Siemens IC 10 AO 2014
Siemens AG 2014
DT
Screw terminals
Article No.
Size
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
Signaling switches1)
Separate tripped and
One signaling switch short-circuit alarms,
1 NO + 1 NC each
can be mounted on
the left per motor
starter protector.
S0, S2, S3
Signaling switches
3RV1921-1M
1 unit
41E
3RV1928-1A
1 unit
41E
3RV1938-1A
1 unit
41E
DT
Screw terminals
PU
(UNIT,
SET, M)
PS*
PG
3RV1921-1M
Isolator modules1)
Isolator modules
3RV1938-1A
with padlock
This accessory cannot be used for the 3RV1742 circuit breakers.
AC
60 Hz
1)
DC
100 %
ON period1)
AC/DC
50/60 Hz,
DC
5s
ON period2)
Size
AC
50/60 Hz
Article No.
V
Price
per PU
Auxiliary releases3)
Undervoltage releases
3RV1902-1DP0
-24
110
--
--120
208
-----
-----
24
----
A
A
A
A
3RV1902-1AB4
3RV1902-1AB0
3RV1902-1AF0
3RV1902-1AM1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
230
400
415
500
240
440
480
600
-----
-----
-----
}
}
A
A
3RV1902-1AP0
3RV1902-1AV0
3RV1902-1AV1
3RV1902-1AS0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
3RV1912-1CP0
230
400
415
240
440
480
----
----
----
S00
S00
S00
A
A
A
3RV1912-1CP0
3RV1912-1CV0
3RV1912-1CV1
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
230
400
415
240
440
480
----
----
----
S0, S2, S3
S0, S2, S3
S0, S2, S3
A
A
A
3RV1922-1CP0
3RV1922-1CV0
3RV1922-1CV1
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
20 ... 24
90 ... 110
210 ... 240
350 ... 415
500
20 ... 70
70 ... 190
190 ... 330
330 ... 500
500
------
}
A
}
A
A
3RV1902-1DB0
3RV1902-1DF0
3RV1902-1DP0
3RV1902-1DV0
3RV1902-1DS0
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
41E
Shunt releases
------
------
1)
The voltage range is valid for 100 % (infinite) ON period. The response
voltage lies at 0.9 of the lower limit of the voltage range.
2)
The voltage range is valid for 5 s ON period at AC 50/60Hz and DC. The
response voltage lies at 0.85 of the lower limit of the voltage range.
3)
One auxiliary release can be mounted on the right per motor starter protector (does not apply to 3RV11 motor starter protectors with overload relay
function).
Siemens IC 10 AO 2014
7/19
Siemens AG 2014
Overview
Insulated three-phase busbar system
Three-phase busbar systems provide an easy, time-saving and
clearly arranged means of feeding 3RV1 motor starter protectors/circuit breakers with screw terminals. Different designs are
available for sizes S00, S0 and S2 and can be used for the various different versions of motor starter protectors/circuit breakers. The 3RV1915 three-phase busbar systems are not suitable
for 3RV11 motor starter protectors for motor protection with overload relay function.
The busbars are suitable for between 2 and 5 motor starter
protectors/circuit breakers. However, any kind of extension is
possible by clamping the tags of an additional busbar (rotated
by 180) underneath the terminals of the respective last motor
starter protector/circuit breaker.
A combination of motor starter protectors of different sizes is
possible only with sizes S00 and S0. Connecting pieces are
available for this purpose. The motor starter protectors are
supplied by appropriate infeed terminals.
3RV1915-5A
3RV1915-1CB
NSB0_01073d
rotated
by 180
The three-phase busbar systems are finger-safe. They are designed for any short-circuit stress which can occur at the output
side of connected motor starter protectors/circuit breakers.
3RV1915-5B
3RV1915-6AB
3RV1935-1C
3RV1935-1A
NSB0_01074c
3RV1935-6A
3RV1915-1AB
3RV1915-6AB
7/20
Siemens IC 10 AO 2014
Siemens AG 2014
auxiliary
switch
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
auxiliary
release
mm
Size
Three-phase busbars
3RV1915-1AB
451)
2
3
4
5
--
--
63
S00, S0
S00, S0
S00, S0
S00, S0
}
}
}
}
3RV1915-1AB
3RV1915-1BB
3RV1915-1CB
3RV1915-1DB
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
3RV1915-1BB
551)
--
2
3
4
5
--
63
S00, S0
S00, S0
S00, S0
S00, S0
}
}
}
}
3RV1915-2AB
3RV1915-2BB
3RV1915-2CB
3RV1915-2DB
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
631)
--
--
2
4
63
S00, S0
S00, S0
}
}
3RV1915-3AB
3RV1915-3CB
1
1
1 unit
1 unit
41E
41E
551)
2
3
4
--
--
108
S2
S2
S2
}
}
}
3RV1935-1A
3RV1935-1B
3RV1935-1C
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
752)
--
2
3
4
2
3
4
108
S2
S2
S2
}
}
}
3RV1935-3A
3RV1935-3B
3RV1935-3C
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
3RV1915-1CB
3RV1915-1DB
1)
Not suitable for 3RV11 motor starter protectors for motor protection with
overload relay function. Common clamping of S00 and S0 motor starter
protectors is not possible, due to the different modular spacings and
terminal heights. The 3RV1915-DB connecting piece is available for
connecting busbars from size S0 to size S00.
Version
2)
For 3RV1 motor starter protectors with accessories mounted on the side.
Auxiliary releases and lateral auxiliary/signaling switches cannot be used
in combination.
Modular
spacing
For motor
starter
protectors
mm
Size
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41E
PU
(UNIT,
SET, M)
PS*
PG
3RV1915-5DB
S00, S0
3RV1915-5DB
Conductor cross-section
Tightening
torques
For motor
starter
protectors
DT
Article No.
Price
per PU
Solid or
stranded
Finely
stranded
with end
sleeve
AWG
cables,
solid or
stranded
mm
mm
AWG
Nm
Size
10 ... 4
S00
3RV1915-5A
1 unit
41E
S0
3RV1925-5AB
1 unit
41E
4 ... 16
2.5 ... 25
4 ... 16
10 ... 4
Inputs: 4,
Output:
2 ... 2.5
S00, S0
3RV1915-5B
1 unit
41E
14 ... 0
S2
3RV1935-5A
1 unit
41E
1.5 ... 35
3RV1915-5B
1)
2.5 ... 25
4 ... 16
10-4
2 ... 4
S0
3RV1925-5EB
1 unit
41E
10 ... 50
--
8 ... 0
4.5 ... 6
S2
3RV1935-5E
1 unit
41E
Siemens IC 10 AO 2014
7/21
Siemens AG 2014
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
S00, S0
3RV1915-6AB
1 10 units
41E
S2
3RV1935-6A
5 units
41E
PU
(UNIT,
SET, M)
PS*
PG
Size
8US1061-5FK08
8US1111-4SM00
8US1261-5FM08
8US1211-4TR00
Adapter
length
Adapter
width
Rated voltage
Size
mm
mm
AWG
DT
Article No.
Price
per PU
25
25
12
12
121
121
45
55
690
690
}
}
8US1051-5DJ07
8US1061-5DJ07
1
1
1 unit
1 unit
14O
14O
S2
S3
S3
56
100
100
8
4
4
139
182
182
55
70
72
690
4001)
415 ... 6902)
}
}
}
8US1061-5FK08
8US1111-4SM00
8US1011-4TM00
1
1
1
1 unit
1 unit
1 unit
14O
14O
14O
182
182
182
182
215
45
55
70
72
72
690
690
4001)
415 ... 6902)
6004)
}
}
}
A
A
8US1251-5DM07
8US1261-5FM08
8US1111-4SM00
8US1211-4TM00
8US1211-4TR00
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
14O
14O
14O
14O
14O
25
56
100
100
704)
12
8
4
4
4
1)
At rated voltage
400 V: short-circuit breaking capacity 50 kA,
> 400 to 460 V: short-circuit breaking capacity 25 kA.
2)
3)
This busbar adapter is approved specially for 3RV1742 circuit breakers for
applications according to UL/CSA.
4)
7/22
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Door-coupling rotary operating mechanisms
NSB0_00007a
NSB0_01079a
RESET function
The RESET button on the motorized operating mechanism
serves to reset any 3RV1921-1M signaling switch that might be
installed.
Siemens IC 10 AO 2014
7/23
NSB0_01078
Siemens AG 2014
Color of
handle
Version of
For motor
extension shaft starter
protectors/
circuit
breakers
mm
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
Size
130
330
S0, S2, S3
S0, S2, S3
}
}
3RV2926-0B
3RV2926-0K
1
1
1 unit
1 unit
41E
41E
EMERGENCY
Red/yellow 130
STOP door330
coupling rotary
operating
mechanisms
S0, S2, S3
S0, S2, S3
}
}
3RV2926-0C
3RV2926-0L
1
1
1 unit
1 unit
41E
41E
Door-coupling Black
rotary operating
mechanisms
Laterally mountable auxiliary releases and two-pole auxiliary switches can be used.
The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60947-2.
300
S0
S2
S3
}
}
}
3RV2926-2B
3RV2936-2B
3RV2946-2B
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
EMERGENCY
Red/yellow 300
STOP doorcoupling rotary
operating
mechanisms
S0
S2
S3
}
}
}
3RV2926-2C
3RV2936-2C
3RV2946-2C
1
1
1
1 unit
1 unit
1 unit
41E
41E
41E
Version
For motor
starter
protectors/
circuit
breakers
DT
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Door-coupling Gray
rotary operating
mechanisms
3RV2936-2B
Price
per PU
Size
S2
S2
X
X
3RV1936-3AP0
3RV1936-3AB4
1
1
1 unit
1 unit
41E
41E
S3
S3
X
X
3RV1946-3AP0
3RV1946-3AB4
1
1
1 unit
1 unit
41E
41E
3RV19.6-3A..
7/24
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Solder pin connections
Solder pin connections are available for the main contacts and
transverse auxiliary switches of size S00 motor starter protectors.
The prepared terminal parts are clamped to the upper and lower
screw terminals of the motor starter protectors which allows
them to be soldered into printed circuit boards.
NSB0_01380b
NSB0_01379b
NSB0_01077b
For motor
starter
protectors/
circuit
breakers
DT
Article No.
B
}
Terminal covers
For cable lug and busbar connection for
maintaining the required voltage clearance and
as touch protection if box terminal is removed
(2 units can be mounted per motor starter
protector/circuit breaker)
S3
Scale covers
Sealable,
for covering the set current scale
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RT1936-4EA2
3RT1946-4EA2
1
1
1 unit
1 unit
41B
41B
3RT1946-4EA1
1 unit
41B
3RV1908-0P
100 10 units
41E
Size
Covers
Siemens IC 10 AO 2014
7/25
Siemens AG 2014
For motor
starter
protectors
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
S00, S0
3RB1900-0B
100 10 units
41F
S00
3RV1918-5A
4 units
41E
S00
3RV1918-5B
4 units
41E
}
B
3RV1928-1H
3RT1946-4GA07
1
1
1 unit
1 unit
41E
41B
3RT1946-4F
1 unit
41B
Size
Fixing accessories
Push-in lugs
For screwing the motor starter protector onto
mounting plates
For each motor starter protector, 2 units are
required.
3RB1900-0B
3RV1928-1H
With size S0, these terminal blocks cannot be used in combination with 3RV19.5 3-phase busbars and with size S3, they
cannot be used with a transverse auxiliary switch.
3RT1946-4GA07
S3
3RT1946-4F
7/26
Siemens IC 10 AO 2014
Siemens AG 2014
Size
Contactor
DT
Screw terminals
Motor starter
protectors/
circuit breakers
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA1931-1AA00
AC/DC
S00
S00
S00
S0
}
}
3RA1911-1AA00
3RA1921-1DA00
1
1
1 unit
1 unit
41B
41B
AC
S0
S2
S3
S0
S2
S3
}
}
}
3RA1921-1AA00
3RA1931-1AA00
3RA1941-1AA00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
DC
S0
S2
S3
S0
S2
S3
}
}
}
3RA1921-1BA00
3RA1931-1BA00
3RA1941-1BA00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
AC/DC
S00
S00
S00
S0
}
}
3RA1911-1A
3RA1921-1D
1 10 units
1 10 units
41B
41B
AC
S0
S2
S3
S0
S2
S3
}
}
}
3RA1921-1A
3RA1931-1A
3RA1941-1A
1 10 units
1
5 units
1
5 units
41B
41B
41B
DC
S0
S2
S3
S0
S2
S3
}
}
}
3RA1921-1B
3RA1931-1B
3RA1941-1B
1 10 units
1
5 units
1
5 units
41B
41B
41B
3RA1941-1AA00
3RA1931-1A
S00
S00
S00
S0
}
}
3RA1911-2FA00
3RA1921-2FA00
1
1
1 unit
1 unit
41B
41B
S00
S00
S00
S0
}
}
3RA1911-2F
3RA1921-2F
1 10 units
1 10 units
41B
41B
Multi-unit packaging
AC/DC
3RA1911-2FA00
3RA1911-2F
Siemens IC 10 AO 2014
7/27
Multi-unit packaging
Siemens AG 2014
DT
PU
(UNIT,
SET, M)
Spring-type
terminals
Article No.
PS*
PG
Price
per PU
Size
3RA1911-2A
1 10 units
41B
S00
3RA1911-2E
1 10 units
41B
3RA1922-1L
5 units
41B
Link modules
with mechanical connection
Mechanical and electrical connection
between motor starter protector and
contactor
Busbar adapters
45 mm wide, 182 mm long, adapted for
motor starter protectors with spring-type
terminals. If there is an additional contactor,
a further standard mounting rail must be
fitted.
40 mm busbar
systems
8US1051-5CM47
1 unit
14O
60 mm busbar
systems
8US1251-5CM47
1 unit
14O
--
8US1998-7CA15
1 10 units
14O
Version
Color
3RA1911-2A +
8US1051-5CM47
3RA1911-2E
Size
For motor DT
starter
protectors/
circuit
breakers
Spring-type
terminals
Article No.
Size
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41B
Price
per PU
Length approx.
200 mm,
3.0 mm x 0.5 mm
Titanium
gray/
black,
partially
insulated
S00, S0,
S2, S3
3RA2908-1A
3RA2908-1A
7/28
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Enclosures
For installing motor starter protectors in sizes S00 (In max = 12 A),
S0 (In max = 25 A) and S2 (In max = 50 A) as a single unit,
molded-plastic and cast aluminum enclosures for surface
mounting and molded-plastic enclosures for flush mounting are
available in various dimensions.
When installed in a molded-plastic enclosure the motor starter
protectors have a rated operational voltage Ue of 500 V.
The enclosures for surface mounting have the degree of protection IP55; the enclosures for flush mounting also comply with the
degree of protection IP55 at the front (the flush-mounted section
complies with IP20).
NSB0_01082b
NSB0_01080b
Front plates
NSB0_01081b
3RV1913-7D
3RV1913-6B
3RV1913-7E
NSB0_01083b
The narrow enclosure can accommodate a motor starter protector without accessories, with transverse and lateral auxiliary
switch, whereas wide enclosures and enclosures for S2 motor
starter protectors also provide space for a laterally mounted auxiliary release. There is no provision for installing a motor starter
protector with a signaling switch.
Accessories for size S00
Siemens IC 10 AO 2014
7/29
Siemens AG 2014
Degree of
protection
Integrated
terminals
Mounting width
For 3RV10 DT
to 3RV16
motor
starter
protectors
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
Size
IP55
3RV1913-1DA00
3RV1923-1FA00
With
IP55
EMERGENCYSTOP rotary
operating
mechanism,
lockable in
0 position
3RV1913-1CA00
1 unit
41E
72 mm
S00
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1913-1DA00
1 unit
41E
S0
3RV1923-1CA00
1 unit
41E
72 mm
S0
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1923-1DA00
1 unit
41E
82 mm
S2
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1933-1DA00
1 unit
41E
S0
3RV1923-1FA00
1 unit
41E
72 mm
S0
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1933-1GA00
1 unit
41E
82 mm
S2
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1933-1GA00
1 unit
41E
N and
54 mm
PE/ground (for switch +
lateral auxiliary
switch)
S00
N and
54 mm
PE/ground (for switch +
lateral auxiliary
switch)
N and
54 mm
PE/ground (for switch +
lateral auxiliary
switch)
3RV1923-1DA01
PE1)
72 mm
S0
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1923-1DA01
1 unit
41E
With
IP65
EMERGENCYSTOP rotary
operating
mechanism,
lockable in
0 position
PE1)
72 mm
S0
(for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1923-1GA01
1 unit
41E
N and
72 mm
S00
PE/ground (for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1913-2DA00
1 unit
41E
N and
72 mm
S0
PE/ground (for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1923-2DA00
1 unit
41E
With
IP55
EMER(front side)
GENCYSTOP rotary
operating
mechanism,
lockable in
0 position
N and
72 mm
S0
PE/ground (for switch +
lateral auxiliary
switch +
auxiliary release)
3RV1923-2GA00
1 unit
41E
3RV1913-2DA00
3RV1923-2DA00
1)
IP55
(front side)
7/30
Siemens IC 10 AO 2014
Siemens AG 2014
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
Size
Front plates
S00
3RV1913-4C
1 unit
41E
IP55
(front
side)
S0, S2, S3
3RV1923-4B
1 unit
41E
IP55
(front
side)
S0, S2, S3
3RV1923-4E
1 unit
41E
--
S0
3RV1923-4G
1 unit
41E
IP55
S00
3RV1913-7D
1 unit
41E
IP55
S00
3RV1913-7E
1 unit
41E
IP55
S00
3RV1913-6B
1 unit
41E
IP55
S00
3RV1913-7F
1 unit
41E
PU
(UNIT,
SET, M)
PS*
PG
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41E
41E
41E
41E
IP55
(front
For actuating 3RV1 motor starter protectors in side)
any enclosures, includes holder for motor
starter protector.
Molded-plastic front plates
with actuator diaphragm
3RV1913-4C
3RV1923-4B +
3RV1923-4G
Molded-plastic
enclosure for surface
RONIS lock,
mounting with
lock No. SB 30,
3RV1913-7D
supplied with 2 keys
Size
S2
Article No.
Price
per PU
Indicator lights
Indicator lights
for all enclosures and front plates
With LED lamp for
versions 110 ... 120 V,
with glow lamp for
versions 220 ... 500 V
3RV1903-5B
C
C
C
C
3RV1903-5B
3RV1903-5C
3RV1903-5E
3RV1903-5G
Siemens IC 10 AO 2014
7/31
Siemens AG 2014
Overview
The 3RV19 infeed system is a convenient means of energy
supply and distribution for a group of several motor starter
protectors or complete load feeders with a screw or spring-type
connection up to size S0 (exception: this system cannot be used
for the 3RV11, 3RV16 and 3RV1742 motor starter protectors/
circuit breakers).
The devices with spring-type connections are available in the
SIRIUS modular system up to 5.5 kW at 400 V AC. The motor
starter protectors and load feeders with screw terminals for sizes
S00 and S0 can also be integrated in the system at the same
time.
The system is based on a basic module complete with a lateral
incoming unit (three-phase busbar with infeed). This infeed with
spring-type terminals is mounted on the right or left depending
on the version and can be supplied with a maximum conductor
cross-section of 25 mm2 (with end sleeve). A basic module has
two sockets onto each of which a motor starter protector can be
snapped.
3b
3a
NSB0_01415b
6
1
3a
Expansion plug
3b
End cover
Plug-in connector
Contactor base
Terminal block
7/32
Siemens IC 10 AO 2014
Siemens AG 2014
* Contactor base
Load feeders can be assembled in the system using the contactor base. The contactor bases are suitable for contactors of size
S00 with spring-type terminals and are simply snapped onto the
three-phase busbars. Direct-on-line starters and reversing starters are possible. One contactor base is required for direct-online starters and two are required for reversing starters. To assemble load feeders for reversing starters, the contactor bases
can be arranged either below each other (45 mm overall width)
or alongside each other (90 mm overall width). It is important to
note that mechanical interlocking of the contactors is only possible when they are arranged vertically.
( End cover
The end cover is used to cover the three-phase busbar at the
open end of the system. This cover is therefore only required
once for each system. An end cover is supplied with each threephase busbar system with infeed. Further end covers are therefore only required as spare parts.
) Plug-in connector
The infeed system is designed for mounting on a 35 mm standard mounting rail with 7.5 mm overall depth. This standard
mounting rail gives the contactor base a stable mounting surface to sit on. If standard mounting rails with a depth of 15 mm
are used, the spacer connected to the bottom of the contactor
base must be knocked out and plugged into the mating piece
that is also on the underside. Then the contactor base also has
a stable mounting surface. When standard mounting rails with a
depth of 7.5 mm are used, the spacer has no function and can
be removed.
As an alternative to using a contactor base, the 3RA1911-2E
electrical link modules can also be used for direct start load
feeders with spring-type connections of size S00. Motor starter
protector and contactor assemblies can then be directly
snapped onto the sockets of the three-phase busbars. For
feeders of size S00 and S0, the corresponding 3RA1911-1.... or
3RA1921-1.... link modules should generally be used. For size
S0, it is only possible to integrate direct start load feeders and
they must be integrated in the system as complete assemblies.
+ Terminal block
The 3RV1917-5D terminal block enables the integration of not
only SIRIUS motor starter protectors but also single-phase,
two-phase and three-phase components. Using the terminal
block the 3 phases can be fed out of the system; which means
that single-phase loads can also be integrated in the system.
The terminal block is plugged into the slot of the expansion plug
and thus enables outfeeding from the middle or end of the infeed
system. The terminal block can be rotated through 180 and be
locked to the support modules of the infeed system. In addition,
the 45 mm wide 3RV1917-7B standard mounting rail option for
screwing onto the support plate facilitates plugging the singlephase, two-phase and three-phase components onto the infeed
system.
The plug-in connector is used for the electrical connection between the three-phase busbar and the motor starter protector.
These plug-in connectors are available in versions with screw
terminals for sizes S00, S0 or with spring-type terminals for size
S00.
Siemens IC 10 AO 2014
7/33
Siemens AG 2014
Version
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RV1917-1A
1 unit
41E
3RV1917-1E
1 unit
41E
Size
3RV1917-1A
Three-phase
busbars
Incl.
3RV1917-5BA00
expansion plug
S00
(spring-type)1),
S00, S0 (screw)
3RV1917-4A
1 unit
41E
S00
(spring-type)1),
S00, S0 (screw)
3RV1917-4B
1 unit
41E
3RV1917-5AA00
1 unit
41E
Multi-unit packaging
3RV1917-5A
1 10 units
41E
41E
3RV1917-4B
Plug-in connectors
Plug-in
connectors
To make contact
with the motor
starter protectors
S00
(spring-type)1)
3RV1917-5AA00
A
3RV1917-5CA00
1 unit
S0 (screw)
3RV1927-5AA00
1 unit
41E
S00 (screw)
3RV1917-5C
1 10 units
41E
S0 (screw)
3RV1927-5A
1 10 units
41E
For contactors
DT
Article No.
Multi-unit packaging
3RV1927-5AA00
1)
Version
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RV1917-7AA00
1 unit
41E
3RV1917-7A
1 10 units
41E
Size
Contactor bases
Contactor bases
For mounting
direct-on-line or
reversing starters
S00
3RV1917-7A
7/34
Siemens IC 10 AO 2014
Siemens AG 2014
Version
DT
Article No.
Single-unit packaging
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RV1917-5D
1 unit
41E
3RV1917-7B
1 unit
41E
Single-unit packaging
3RV1917-5E
1 unit
41E
Expansion plugs1)
As spare part
Single-unit packaging
3RV1917-5BA00
1 unit
41E
End covers2)
As spare part
Multi-unit packaging
3RV1917-6A
100 10 units
41E
Terminal block
Terminal blocks
Single-unit packaging
For integration of single-phase,
two-phase and three-phase
components
3RV1917-5D
3RV1917-7B
3RV1917-5E
Expansion plugs
3RV1917-5BA00
End covers
3RV1917-6A
1)
2)
Siemens IC 10 AO 2014
7/35
Siemens AG 2014
Overload Relays
General data
Overview
Features
3RU11
3RB20/3RB21
3RB22/3RB23
Benefits
General data
S00 ...S3
Sizes
Are coordinated with the dimensions, connections and technical characteristics of the other devices in the SIRIUS modular
system (contactors, etc., ...)
Permit the mounting of slim and compact load feeders in widths
of 45 mm (S00), 45 mm (S0), 55 mm (S2), 70 mm (S3), 120 mm
(S6) and 145 mm (S10/S12); this does not include the current
measuring modules for the 3RB22 to 3RB23 evaluation modules
sizes S00 to S3
Simplify configuration
Tripping due to
overload
Tripping due to
phase unbalance
--
--2)
--2)
Seamless
current range
Protection functions
by
--
(only 3RB21)
by
Features
RESET function
Remote RESET function
(by means of
(only with 3RB21
separate module)
and external
auxiliary voltage
24 V DC)
--
Status display
(2 )
Available
Siemens IC 10 AO 2014
1)
2)
-- Not available
7/36
Siemens AG 2014
Overload Relays
General data
Features
3RU11
3RB20/3RB21
3RB22/3RB23
Benefits
1)
Simplifies configuration
Reduces wiring outlay and costs
Enables stand-alone installation as well as space-saving direct
mounting
Straight-through transformers
for main circuit2)
(in this case the cables are routed
through the feed-through openings
of the overload relay and connected directly to the box terminals
of the contactor)
--
Other features
Temperature compensation
--
(1:4)
(1:10)
CLASS 10
CLASS 10 or
CLASS 20
(only 3RB20)
--
--
(only 3RB21)
Provides safe protection for the loads even after years of use in
severe operating conditions
Minimize the configuration outlay and costs
Minimize storage overheads, storage costs, tied-up capital
--
Available
1)
-- Not available
2)
Siemens IC 10 AO 2014
7/37
Siemens AG 2014
Overload Relays
General data
Features
3RU11
3RB20/3RB21
3RB22/3RB23
Benefits
--1)
--
--
(only 3RB21)
--
--
--
--
1)
Available
-- Not available
7/38
Siemens IC 10 AO 2014
The SIRIUS 3RU11 thermal overload relays use a bimetal contactor and
therefore do not require a control supply voltage.
Siemens AG 2014
Overload Relays
General data
Overload relays overview matching contactors
Overload
relays
Current
Current
measure- range
ment
Type
Type
3RT102.
3RT103.
3RT104.
S00
S0
S2
S3
3/4/5.5
3RT105.
3RT106.
3RT107.
S6
S10
S12
55/75/90
110/132/160 200/250
3TF68/3TF69
Size 14
375/450
Integrated 0.11 12
--
--
--
--
--
--
3RU112
Integrated 1.8 25
--
--
--
--
--
--
--
3RU113
Integrated 5.5 50
--
--
--
--
--
--
--
3RU114
Integrated 18 100
--
--
--
--
--
--
--
--
--
3RU11
3RB20
3RB201
Integrated 0.1 12
--
--
--
--
--
--
3RB202
Integrated 0.1 25
--
--
--
--
--
--
--
3RB203
Integrated 6 50
--
--
--
--
--
--
--
3RB204
--
--
--
--
--
--
--
3RB205
Integrated 50 200
--
--
--
--
--
--
--
3RB206
Integrated 55 630
--
--
--
--
--
--
--
--
--
--
--
--
--
3RB21
3RB211
Integrated 0.1 12
--
--
--
--
--
--
3RB212
Integrated 0.1 25
--
--
--
--
--
--
--
3RB213
Integrated 6 50
--
--
--
--
--
--
--
3RB214
--
--
--
--
--
--
--
3RB215
Integrated 50 200
--
--
--
--
--
--
--
3RB216
Integrated 55 630
--
--
--
--
--
--
--
--
--
--
--
--
--
0.3 25
--
--
--
--
--
3RB290
3RB2283/
3RB2383 3RB29
+
3RB296
10 100
--
--
--
--
20 200
--
--
--
--
--
--
--
63 630
--
--
--
--
--
--
--
--
--
--
--
--
3RB22, 3RB23
Available
-- Not available
1)
Connection methods
The 3RU11 thermal overload relays come with screw terminals.
The 3RB20 and 3RB21 solid-state overload relays are available
with screw terminals (box terminals) or spring-type terminals on
the auxiliary current side; the same applies for the evaluation
modules of the 3RB22 to 3RB23 solid-state overload relays for
High-Feature applications.
Screw terminals
Spring-type terminals
The terminals are indicated in the corresponding tables
by the symbols shown on orange backgrounds.
Siemens IC 10 AO 2014
7/39
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 up to 100 A
for standard applications
X
Y
NSB0_01622a
Overview
The 3RU11 thermal overload relays up to 100 A have been designed for inverse-time delayed protection of loads with normal
starting ("Function" see Reference Manual "Protection
Equipment 3RU1, 3RB2 Overload Relays") against excessive
temperature rises due to overload or phase failure.
Z
\
[
^
]
The "tripped" status is signaled by means of a switch position indicator. Resetting takes place either manually or automatically
after a recovery time has elapsed (for "Function", see Reference
Manual "Protection Equipment 3RU1 and 3RB2 Overload
Relays").
The devices are manufactured in accordance with environmental guidelines and contain environmentally-friendly and reusable
materials.
\ STOP button:
If the STOP button is pressed, the NC contact is opened. This
switches off the contactor downstream. The NC contact is closed
again when the button is released.
The 3RU11 thermal overload relays are suitable for the overload
protection of explosion-proof motors with "increased safety" type
of protection EEx e.
^ Supply terminals:
The generously sized terminals permit connection of two conductors
with different cross-sections for the main and auxiliary circuits. The
auxiliary circuit can be connected with screw terminals and
alternatively with spring-type terminals.
1st - 3rd
4th
5th
6th
7th
@@@
8th
1
@
Device series
Size, rated operational current and power
Setting range of the overload release
Connection methods
Installation type
3RU
Example
Note:
The Article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.
For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.
7/40
Siemens IC 10 AO 2014
3RU
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 up to 100 A
for standard applications
Benefits
The most important features and benefits of the 3RU11 thermal
overload relays are listed in the overview table (see "General
Data", page 7/36 onwards).
Application
Industries
Ambient conditions
The 3RU11 thermal overload relays have temperature compensation in accordance with IEC 60947-4-1 for the temperature
range of 20 to +60 C. For temperatures from +60 to +70 C the
upper set value of the setting range must be reduced by the
factor listed in the table below.
Application
Ambient temperature
C
+60
1.0
+65
0.94
+70
0.87
The 3RU11 thermal overload relays have been designed for the
protection of three-phase and single-phase AC and DC motors.
Siemens IC 10 AO 2014
7/41
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 up to 100 A
for standard applications
Current setting
value of the
inverse-time
delayed overload
release
Short-circuit
DT
protection with
fuse, type of coordination "2", operational class gG4)
PU
(UNIT,
SET, M)
PS*
PG
kW
0.04
0.06
0.06
0.09
0.5
1
1
1.6
}
}
}
}
3RU1116-0AB0
3RU1116-0BB0
3RU1116-0CB0
3RU1116-0DB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.09
0.12
0.18
0.18
2
2
2
4
}
}
}
}
3RU1116-0EB0
3RU1116-0FB0
3RU1116-0GB0
3RU1116-0HB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
4
4
6
6
}
}
}
}
3RU1116-0JB0
3RU1116-0KB0
3RU1116-1AB0
3RU1116-1BB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.75
1.1
1.5
1.5
10
10
16
20
}
}
}
}
3RU1116-1CB0
3RU1116-1DB0
3RU1116-1EB0
3RU1116-1FB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
2.2
3
4
5.5
20
25
35
35
}
}
}
}
3RU1116-1GB0
3RU1116-1HB0
3RU1116-1JB0
3RU1116-1KB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.75
1.1
1.5
1.5
10
10
16
20
}
}
}
}
3RU1126-1CB0
3RU1126-1DB0
3RU1126-1EB0
3RU1126-1FB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
2.2
3
4
5.5
20
25
35
35
}
}
}
}
3RU1126-1GB0
3RU1126-1HB0
3RU1126-1JB0
3RU1126-1KB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
40
50
63
63
}
}
}
}
3RU1126-4AB0
3RU1126-4BB0
3RU1126-4CB0
3RU1126-4DB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
3
4
5.5
5.5 ... 8
7 ... 10
9 ... 12.5
25
35
35
}
}
}
3RU1136-1HB0
3RU1136-1JB0
3RU1136-1KB0
1
1
1
1 unit
1 unit
1 unit
41F
41F
41F
7.5
7.5
11
15
11 ... 16
14 ... 20
18 ... 25
22 ... 32
40
50
63
80
}
}
}
}
3RU1136-4AB0
3RU1136-4BB0
3RU1136-4DB0
3RU1136-4EB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
18.5
22
22
28 ... 40
36 ... 45
40 ... 50
80
100
100
}
}
}
3RU1136-4FB0
3RU1136-4GB0
3RU1136-4HB0
1
1
1
1 unit
1 unit
1 unit
41F
41F
41F
11
15
18 ... 25
22 ... 32
63
80
}
}
3RU1146-4DB0
3RU1146-4EB0
1
1
1 unit
1 unit
41F
41F
18.5
22
30
37
28 ... 40
36 ... 50
45 ... 63
57 ... 75
80
125
125
160
}
}
}
}
3RU1146-4FB0
3RU1146-4HB0
3RU1146-4JB0
3RU1146-4KB0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
45
45
70 ... 90
80 ... 1005)
160
200
}
}
3RU1146-4LB0
3RU1146-4MB0
1
1
1 unit
1 unit
41F
41F
Screw terminals
(on auxiliary current
side)
Article No.
Price
per PU
Size S00
S00
3RU1116-..B0
Size S0
S0
3RU1126-..B0
Size S2
S2
3RU1136-..B0
Size S3
S3
3RU1146-..B0
1)
With the suitable terminal supports (see "Accessories", page 7/45), the
3RU11 overload relays for mounting onto contactor can also be installed
as stand-alone units.
2)
3)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
7/42
Siemens IC 10 AO 2014
4)
5)
For overload relays > 100 A see 3RB2 solid-state overload relays on
page 7/49 onwards.
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 up to 100 A
for standard applications
3RU11 thermal overload relays with screw terminals on the auxiliary current side for stand-alone installation1), CLASS 10
Current setting
value of the
inverse-time
delayed overload
release
Short-circuit
DT
protection with fuse,
type of
coordination "2",
operational
class gG4)
PU
(UNIT,
SET, M)
PS*
PG
kW
0.04
0.06
0.06
0.09
0.5
1
1
1.6
B
B
B
B
3RU1116-0AB1
3RU1116-0BB1
3RU1116-0CB1
3RU1116-0DB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.09
0.12
0.18
0.18
2
2
2
4
}
}
}
}
3RU1116-0EB1
3RU1116-0FB1
3RU1116-0GB1
3RU1116-0HB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
4
4
6
6
}
}
}
}
3RU1116-0JB1
3RU1116-0KB1
3RU1116-1AB1
3RU1116-1BB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.75
1.1
1.5
1.5
10
10
16
20
}
}
}
}
3RU1116-1CB1
3RU1116-1DB1
3RU1116-1EB1
3RU1116-1FB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
2.2
3
4
5.5
20
25
35
35
}
}
}
}
3RU1116-1GB1
3RU1116-1HB1
3RU1116-1JB1
3RU1116-1KB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
S0
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
40
50
63
63
}
}
}
}
3RU1126-4AB1
3RU1126-4BB1
3RU1126-4CB1
3RU1126-4DB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
S2
15
18.5
22
22
22 ... 32
28 ... 40
36 ... 45
40 ... 50
80
80
100
100
}
}
}
}
3RU1136-4EB1
3RU1136-4FB1
3RU1136-4GB1
3RU1136-4HB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
S3
30
37
45
45
45 ... 63
57 ... 75
70 ... 90
80 ... 1005)
125
160
160
200
}
}
}
}
3RU1146-4JB1
3RU1146-4KB1
3RU1146-4LB1
3RU1146-4MB1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
Screw terminals
(on auxiliary current
side)
Article No.
Price
per PU
S00
3RU1116-0AB1
Size S0
3RU1116-4AB1
Size S2
3RU1136-4EB1
Size S3
3RU1146-4JB1
1)
2)
3)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
4)
5)
For overload relays > 100 A see 3RB2 solid-state overload relays on
page 7/49 onwards.
Siemens IC 10 AO 2014
7/43
Size S00
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 up to 100 A
for standard applications
3RU11 thermal overload relays with spring-type terminals for mounting onto contactor 1), CLASS 10
Current setting
value of the
inverse-time
delayed overload
release
Short-circuit
DT
protection with fuse,
type of
coordination "2",
operational class gG4)
PU
(UNIT,
SET, M)
PS*
PG
0.04
0.06
0.06
0.09
0.5
1
1
1.6
B
B
B
B
3RU1116-0AC1
3RU1116-0BC1
3RU1116-0CC1
3RU1116-0DC1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.09
0.12
0.18
0.18
2
2
2
4
B
B
}
}
3RU1116-0EC1
3RU1116-0FC1
3RU1116-0GC1
3RU1116-0HC1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.25
0.37
0.55
0.75
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
4
4
6
6
}
}
}
}
3RU1116-0JC1
3RU1116-0KC1
3RU1116-1AC1
3RU1116-1BC1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.75
1.1
1.5
1.5
10
10
16
20
B
}
B
}
3RU1116-1CC1
3RU1116-1DC1
3RU1116-1EC1
3RU1116-1FC1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
2.2
3
4
5.5
20
25
35
35
}
}
}
}
3RU1116-1GC1
3RU1116-1HC1
3RU1116-1JC1
3RU1116-1KC1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
0.75
1.1
1.5
1.5
10
10
16
20
B
B
B
B
3RU1126-1CD0
3RU1126-1DD0
3RU1126-1ED0
3RU1126-1FD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
2.2
3
4
5.5
20
25
35
35
B
B
B
B
3RU1126-1GD0
3RU1126-1HD0
3RU1126-1JD0
3RU1126-1KD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
7.5
7.5
11
11
11 ... 16
14 ... 20
17 ... 22
20 ... 25
40
50
63
63
}
}
}
}
3RU1126-4AD0
3RU1126-4BD0
3RU1126-4CD0
3RU1126-4DD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
3
4
5.5
7.5
5.5 ... 8
7 ... 10
9 ... 12.5
11 ... 16
25
35
35
40
B
B
B
B
3RU1136-1HD0
3RU1136-1JD0
3RU1136-1KD0
3RU1136-4AD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
7.5
11
15
14 ... 20
18 ... 25
22 ... 32
50
63
80
B
B
}
3RU1136-4BD0
3RU1136-4DD0
3RU1136-4ED0
1
1
1
1 unit
1 unit
1 unit
41F
41F
41F
18.5
22
22
28 ... 40
36 ... 45
40 ... 50
80
100
100
}
}
}
3RU1136-4FD0
3RU1136-4GD0
3RU1136-4HD0
1
1
1
1 unit
1 unit
1 unit
41F
41F
41F
11
15
18.5
22
18 ... 25
22 ... 32
28 ... 40
36 ... 50
63
80
80
125
B
B
B
B
3RU1146-4DD0
3RU1146-4ED0
3RU1146-4FD0
3RU1146-4HD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
30
37
45
45
45 ... 63
57 ... 75
70 ... 90
80 ... 100
125
160
160
200
}
}
}
}
3RU1146-4JD0
3RU1146-4KD0
3RU1146-4LD0
3RU1146-4MD0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41F
41F
41F
41F
Spring-type
terminals
(on auxiliary current
side)
Article No.
kW
3RU1116-..C1
Price
per PU
5)6)
Size S01)7)
S0
3RU1116-..D0
Size S21)7)
S2
3RU1136-..D0
Size S31)7)
S3
3RU1146-..D0
1)
With the suitable terminal supports (see "Accessories", page 7/45), the
3RU11 overload relays for mounting onto contactor can also be installed
as stand-alone units.
2)
3)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
7/44
Siemens IC 10 AO 2014
4)
5)
Size S00 for screw and snap-on mounting onto TH 35 standard mounting
rail.
6)
7)
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
Accessories
Overview
Cable release for resetting devices which are difficult to
access (for all sizes)
Electrical remote RESET module in three voltage variants
(for all sizes)
Terminal covers
Size
DT
Article No.
S00
S0
S2
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RU1916-3AA01
1 unit
41F
3RU1926-3AA01
1 unit
41F
3RU1936-3AA01
1 unit
41F
S3
3RU1946-3AA01
1 unit
41F
S00 ... S3
3RU1900-1A
1 unit
41F
S00 ... S3
3SB3000-0EA11
1 unit
41J
Extension plungers
For compensation of the distance between the
pushbutton and the unlatching button of the relay
S00 ... S3
3SX1335
1 unit
41J
Length 400 mm
S00 ... S3
3RU1900-1B
1 unit
41F
Length 600 mm
S00 ... S3
3RU1900-1C
1 unit
41F
Mechanical RESET
3RU1900-1A
with pushbutton and
extension plunger
3RU1900-1.
S00 ... S3
3RU1900-2AB71
1 unit
41F
S00 ... S3
3RU1900-2AF71
1 unit
41F
S00 ... S3
3RU1900-2AM71
1 unit
41F
S3
3RT1946-4EA1
1 unit
41B
3RU1900-2A.71
Terminal covers
Covers for cable lugs and busbar connections
Length 55 mm
Covers for box terminals
Length 20.6 mm
S2
3RT1936-4EA2
1 unit
41B
Length 20.8 mm
S3
3RT1946-4EA2
1 unit
41B
Siemens IC 10 AO 2014
7/45
3RU19.6-3AA01
Siemens AG 2014
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
Accessories
General accessories
Version
Size
Color
For overDT
load relays
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41B
3RA2908-1A
Screwdrivers
Length approx.
For all SIRIUS devices 200 mm,
with spring-type
3.0 mm x 0.5 mm
terminals
Titanium
gray/
black,
partially
insulated
Main and
A
auxiliary
circuit
connection:
3RU1
3RA2908-1A
Pastel
turquoise
3RU1
3RT1900-1SB20
100
340 units
41B
19 mm x 6 mm
Pastel
turquoise
3RU1
3RT1900-1SB60
41B
19 mm x 6 mm
Zinc yellow
3RT1900-1SD60
41B
Blank labels
1)
NSB0_01429b
Adhesive labels
For SIRIUS devices
3RT1900-1SB20
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see Catalog IC 10, Chapter 16, "Appendix" "External Partners").
1)
7/46
Siemens IC 10 AO 2014
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB20, 3RB21 up to 630 A
for standard applications
6
2
5
3
4
1 Switch position indicator and TEST function of the wiring:
Indicates a trip and enables the wiring test.
2 Trip class setting/internal ground-fault detection (only 3RB21):
Using the rotary switch you can set the required trip class and
activate the internal ground-fault detection dependent on the
start-up conditions.
3 Solid-state test (device test):
Enables a test of all important device components and functions.
1st - 3rd
4th
5th
6th
7th
@@@
8th
2
@
Device series
Connection methods
Installation type
Example
3RB
3RB
Note:
The Article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.
For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.
Siemens IC 10 AO 2014
7/47
NSB0_01620b
Overview
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB20, 3RB21 up to 630 A
for standard applications
Benefits
The most important features and benefits of the 3RB20/3RB21
solid-state overload relays are listed in the overview table
(see "General Data", page 7/36 onwards).
Application
Industries
Ambient conditions
Application
The 3RB20 and 3RB21 solid-state overload relays have been
designed for the protection of three-phase motors in sinusoidal
50/60 Hz voltage networks. The relays are not suitable for the
protection of single-phase AC or DC loads.
The 3RU11 thermal overload relays or the 3RB22 to 3RB24 solidstate overload relays can be used for single-phase AC loads.
For DC loads we recommend the 3RU11 thermal overload relay.
at ambient temperature
+50 C
+60 C
3RB2056, 3RB2156
50 ... 200 A
100 %
100 %
3RB2066, 3RB2166
55 ... 250 A
100 %
100 %
3RB2066, 3RB2166
100 %
90 %
Type
7/48
Siemens IC 10 AO 2014
+50 C
+60 C
3RB2056, 3RB2156
50 ... 200 A
100 %
70 %
3RB2066, 3RB2166
55 ... 250 A
100 %
70 %
3RB2066, 3RB2166
100 %
70 %
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB20, 3RB21 up to 630 A
for standard applications
3RB2016-1RB0
Size
contactor4)
3RB2026-1QD0
3RB2036-1UB0
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41G
3RB2046-1ED0
3RB2056-1FW2
3RB2066-1MF2
Rating for
three-phase motor,
rated value5)
Short-circuit
DT
protection with fuse,
type of coordination "2", operational
class gG6)
DT
kW
0.04 0.09
0.1 0.4
3RB2016-1RB0
3RB2016-1RD0
0.12 0.37
0.32 1.25
3RB2016-1NB0
3RB2016-1ND0
0.55 1.5
14
10
3RB2016-1PB0
3RB2016-1PD0
1.1 5.5
3 12
20
3RB2016-1SB0
3RB2016-1SD0
0.04 0.09
0.1 0.4
3RB2026-1RB0
3RB2026-1RD0
0.12 0.37
0.32 1.25
3RB2026-1NB0
3RB2026-1ND0
0.55 1.5
14
10
3RB2026-1PB0
3RB2026-1PD0
1.1 5.5
3 12
20
3RB2026-1SB0
3RB2026-1SD0
3 11
6 25
35
3RB2026-1QB0
3RB2026-1QD0
3 11
6 25
63
3RB2036-1QB0
3RB2036-1QD0
3RB2036-1QW1
3RB2036-1QX1
3RB2036-1UB0
3RB2036-1UD0
3RB2036-1UW1
3RB2036-1UX1
Screw terminals
(on auxiliary current
side)
Price
per PU
Article No.
Price
per PU
Article No.
Spring-type
terminals
(on auxiliary current
side)
Size S001)
S00
Size S01)
S0
Size S21)3)7)
S2
7.5 22
12.5 50
80
Size S31)3)7)
S3
7.5 22
12.5 50
160
3RB2046-1UB0
3RB2046-1UD0
11 45
25 100
315
3RB2046-1EB0
3RB2046-1ED0
3RB2046-1EW1
3RB2046-1EX1
3RB2056-1FC2
3RB2056-1FF2
3RB2056-1FW2
3RB2056-1FX2
Size S62)7)
S6 with busbar 22 90
connection
50 200
315
For mounting to
S6 contactors
with box
terminals
Size S10/S122)
S10/S12
22 110
and size 14
90 450
(3TF68/ 3TF69)
55 250
400
3RB2066-1GC2
3RB2066-1GF2
160 630
800
3RB2066-1MC2
3RB2066-1MF2
1)
The relays with an Article No. ending with "0" are designed for mounting
onto contactor. With the matching terminal supports (see "Accessories",
page 7/52) the sizes S00 and S0 can also be installed as stand-alone
units.
2)
The relays with an Article No. ending with "2" are designed for mounting
onto contactor and stand-alone installation. For 3TF68/3TF69 contactors,
direct mounting is not possible.
3)
The relays with an Article No. ending with "1" are designed for mounting
onto stand-alone installation.
4)
5)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
6)
7)
The relays with an Article No. with "W" or "X" in penultimate position are
equipped with a straight-through transformer.
Siemens IC 10 AO 2014
7/49
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB20, 3RB21 up to 630 A
for standard applications
3RB20 solid-state overload relays for mounting onto contactor1)2) and stand-alone installation2)3), CLASS 20
Features and technical specifications:
Overload protection, phase failure protection and unbalance
protection
Internal power supply
Auxiliary contacts 1 NO + 1 NC
Manual and automatic RESET
Switch position indicator
TEST function and self-monitoring
3RB2016-2RB0
Size
contactor4)
3RB2026-2QD0
3RB2036-2UB0
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41G
3RB2046-2ED0
3RB2056-2FW2
3RB2066-2MF2
Rating for
three-phase motor,
rated value5)
Short-circuit
DT
protection with fuse,
type of coordination "2", operational
class gG6)
DT
kW
0.04 0.09
0.1 0.4
3RB2016-2RB0
3RB2016-2RD0
0.12 0.37
0.32 1.25
3RB2016-2NB0
3RB2016-2ND0
0.55 1.5
14
10
3RB2016-2PB0
3RB2016-2PD0
1.1 5.5
3 12
20
3RB2016-2SB0
3RB2016-2SD0
Screw terminals
(on auxiliary current
side)
Article No.
Price
per PU
Spring-type
terminals
(on auxiliary current
side)
Article No.
Price
per PU
Size S001)
S00
Size S01)
S0
0.04 0.09
0.1 0.4
3RB2026-2RB0
3RB2026-2RD0
0.12 0.37
0.32 1.25
3RB2026-2NB0
3RB2026-2ND0
0.55 1.5
14
10
3RB2026-2PB0
3RB2026-2PD0
1.1 5.5
3 12
20
3RB2026-2SB0
3RB2026-2SD0
3 11
6 25
35
3RB2026-2QB0
3RB2026-2QD0
3 11
6 25
63
Size S21)3)7)
S2
7.5 22
12.5 50
80
3RB2036-2QB0
3RB2036-2QD0
3RB2036-2QW1
3RB2036-2QX1
3RB2036-2UB0
3RB2036-2UD0
3RB2036-2UW1
3RB2036-2UX1
Size S31)3)7)
S3
7.5 22
12.5 50
160
3RB2046-2UB0
3RB2046-2UD0
11 45
25 100
315
3RB2046-2EB0
3RB2046-2ED0
3RB2046-2EW1
3RB2046-2EX1
3RB2056-2FC2
3RB2056-2FF2
3RB2056-2FW2
3RB2056-2FX2
Size S62)7)
S6 with busbar 22 90
connections
50 200
315
For mounting to
S6 contactors
with box
terminals
Size S10/S122)
S10/S12
22 110
and
90 450
size 14
(3TF68/ 3TF69)
55 250
400
3RB2066-2GC2
3RB2066-2GF2
160 630
800
3RB2066-2MC2
3RB2066-2MF2
1)
The relays with an Article No. ending with "0" are designed for mounting
onto contactors. With the matching terminal supports (see "Accessories",
page 7/52) the sizes S00 and S0 can also be installed as stand-alone
units.
2)
The relays with an Article No. ending with "2" are designed for mounting
onto contactor and stand-alone installation. For 3TF68/3TF69 contactors,
direct mounting is not possible.
3)
The relays with an Article No. ending with "1" are designed for mounting
onto stand-alone installation.
4)
7/50
Siemens IC 10 AO 2014
5)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
6)
7)
The relays with an Article No. with "W" or "X" in penultimate position are
equipped with a straight-through transformer.
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB20, 3RB21 up to 630 A
for standard applications
3RB21 solid-state overload relays for mounting onto contactor1)2) and stand-alone installation2)3), CLASS 5, 10, 20 and 30
adjustable
3RB2113-4RB0
Size
contactor4)
3RB2123-4QD0
3RB2133-4UB0
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41G
3RB2143-4ED0
3RB2153-4FX2
3RB2163-4MC2
Rating for
three-phase motor,
rated value5)
Short-circuit
DT
protection with fuse,
type of coordination "2", operational
class gG6)
DT
kW
0.04 0.09
0.1 0.4
3RB2113-4RB0
3RB2113-4RD0
0.12 0.37
0.32 1.25
3RB2113-4NB0
3RB2113-4ND0
0.55 1.5
14
10
3RB2113-4PB0
3RB2113-4PD0
1.1 5.5
3 12
20
3RB2113-4SB0
3RB2113-4SD0
Screw terminals
(on auxiliary current
side)
Article No.
Price
per PU
Spring-type
terminals
(on auxiliary current
side)
Article No.
Price
per PU
Size S001)
S00
Size S01)
S0
0.04 0.09
0.1 0.4
3RB2123-4RB0
3RB2123-4RD0
0.12 0.37
0.32 1.25
3RB2123-4NB0
3RB2123-4ND0
0.55 1.5
14
10
3RB2123-4PB0
3RB2123-4PD0
1.1 5.5
3 12
20
3RB2123-4SB0
3RB2123-4SD0
3 11
6 25
35
3RB2123-4QB0
3RB2123-4QD0
3 11
6 25
63
3RB2133-4QB0
3RB2133-4QD0
3RB2133-4QW1
3RB2133-4QX1
3RB2133-4UB0
3RB2133-4UD0
3RB2133-4UW1
3RB2133-4UX1
Size S21)3)7)
S2
7.5 22
12.5 50
80
Size S31)3)7)
S3
7.5 22
12.5 50
160
3RB2143-4UB0
3RB2143-4UD0
11 45
25 100
315
3RB2143-4EB0
3RB2143-4ED0
3RB2143-4EW1
3RB2143-4EX1
3RB2153-4FC2
3RB2153-4FF2
3RB2153-4FW2
3RB2153-4FX2
Size S62)7)
S6 with busbar 22 90
connections
50 200
315
For mounting to
S6 contactors
with box terminals
Size S10/S122)
S10/S12
22 110
and size 14
90 450
(3TF68/ 3TF69)
55 250
400
3RB2163-4GC2
3RB2163-4GF2
160 630
800
3RB2163-4MC2
3RB2163-4MF2
1)
The relays with an Article No. ending with "0" are designed for mounting
onto contactors. With the matching terminal supports (see "Accessories",
page 7/52) the sizes S00 and S0 can also be installed as stand-alone
units.
2)
The relays with an Article No. ending with "2" are designed for mounting
onto contactor and stand-alone installation. For 3TF68/3TF69 contactors,
direct mounting is not possible.
3)
The relays with an Article No. ending with "1" are designed for mounting
onto stand-alone installation.
4)
5)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
6)
7)
The relays with an Article No. with "W" or "X" in penultimate position are
equipped with a straight-through transformer.
Siemens IC 10 AO 2014
7/51
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Accessories for 3RB20, 3RB21
Overview
Cable release for resetting devices which are difficult to
access (for all sizes)
Sealable cover (for all sizes)
Terminal covers for sizes S2 to S10/S12
Box terminal blocks for sizes S6 and S10/S12
Size
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2913-0AA1
1 unit
41F
S0
3RB2923-0AA1
1 unit
41F
S00 ...
S10/S12
3RU1900-1A
1 unit
41F
S00 ...
S10/S12
3SB3000-0EA11
1 unit
41J
Extension plungers
For compensation of the distance between a
pushbutton and the unlatching button of the relay
S00 ...
S10/S12
3SX1335
1 unit
41J
Length 400 mm
3RU1900-1B
1 unit
41F
Length 600 mm
3RU1900-1C
1 unit
41F
3RB29.3-0AA1
Mechanical RESET
3RU1900-1A
with pushbutton and
extension plunger
S00 ...
S10/S12
3RU1900-1.
7/52
Siemens IC 10 AO 2014
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Accessories for 3RB20, 3RB21
Version
Size
DT
Article No.
S00 ...
S10/S12
Length 55 mm
S3
Length 100 mm
S6
Length 120 mm
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2984-0
1 10 units
41F
3RT1946-4EA1
1 unit
41B
3RT1956-4EA1
1 unit
41B
S10/S12
3RT1966-4EA1
1 unit
41B
Length 20.6 mm
S2
3RT1936-4EA2
1 unit
41B
Length 20.8 mm
S3
3RT1946-4EA2
1 unit
41B
Length 25 mm
S6
3RT1956-4EA2
1 unit
41B
Length 30 mm
S10/S12
3RT1966-4EA2
1 unit
41B
S6
3RT1956-4EA3
1 unit
41B
S10/S12
3RT1966-4EA3
1 unit
41B
Up to 70 mm2
S61)
3RT1955-4G
1 unit
41B
Up to 120 mm2
S6
3RT1956-4G
1 unit
41B
Up to 240 mm2
S10/S12
3RT1966-4G
1 unit
41B
Sealable covers
3RB2984-0
Terminal covers
Covers for cable lugs and busbar connections
3RT1956-4EA1
3RT1936-4EA2
3RT195.-4G
1)
General accessories
Version
Size
Color
For overDT
load relays
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41B
3RA2908-1A
Screwdrivers
Length approx.
For all SIRIUS devices 200 mm,
with spring-type
3.0 mm x 0.5 mm
terminals
Titanium
gray/
black,
partially
insulated
Main and
A
auxiliary
circuit
connection:
3RB2
3RA2908-1A
Pastel
turquoise
3RB2
3RT1900-1SB20
100
340 units
41B
Adhesive labels1)
For SIRIUS devices
19 mm x 6 mm
Pastel
turquoise
3RB2
3RT1900-1SB60
41B
19 mm x 6 mm
Zinc
yellow
3RT1900-1SD60
41B
NSB0_01429b
Blank labels
3RT1900-1SB20
1)
Siemens IC 10 AO 2014
7/53
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB22, 3RB23 up to 630 A
for High-Feature applications
NSB0_01621b
Overview
7
2
6
5
4
2
3
7/54
Siemens IC 10 AO 2014
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB22, 3RB23 up to 630 A
for High-Feature applications
Article No. scheme
Digit of the Article No.
Solid-state overload relays
1st - 3rd
4th
5th
6th
7th
@@@
8th
3RB
2
@
Device series
Connection methods
Installation type
Example
3RB
Note:
The Article No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
article numbers.
For your orders, please use the article numbers quoted in the
catalog in the Selection and ordering data.
Benefits
We offer you a unique portfolio for industrial energy management, using an energy management system that helps to optimally define your energy needs. We split up our industrial
energy management into three phases identify, evaluate, and
realize and we support you with the appropriate hardware and
software solutions in every process phase.
IC0
1_ 0
0 24
Application
Industries
Ambient conditions
Application
The 3RB22 and 3RB23 devices have been designed for the
protection of three-phase asynchronous and single-phase
AC motors.
If single-phase AC motors are to be protected by the 3RB22 and
3RB23 solid-state overload relays, the main current paths of the
current measuring modules must be series-connected
("Schematics" see Reference Manual "Protection Equipment
3RU1, 3RB2 Overload Relays").
Siemens IC 10 AO 2014
7/55
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB22, 3RB23 up to 630 A
for High-Feature applications
3RB2283-4A.1, 3RB2383-4A.1
2 NO + 2 NC
Auxiliary contacts
Analog output
Available
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41G
3RB2283-4AA1,
3RB2383-4AA1
Size of
contactor
3RB2283-4AC1,
3RB2383-4AC1
Version
DT
DT
Screw terminals
Article No.
Price
per PU
Spring-type terminals
Article No.
Price
per PU
Evaluation modules
S00 ... S12
Monostable
3RB2283-4AA1
3RB2283-4AC1
Bistable
3RB2383-4AA1
3RB2383-4AC1
Note:
Overview of overload relays matching contactors see
page 7/39.
7/56
Siemens IC 10 AO 2014
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB22, 3RB23 up to 630 A
for High-Feature applications
Functions of the 3RB22 and 3RB23 evaluation modules in combination with the 3RB2985 function expansion modules
Evaluation modules With function
expansion module
A1/A2
T1/T2
Y1/Y2
--
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2985-2CA1
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2985-2CB1
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2985-2AA0
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2985-2AA1
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2985-2AB1
Power supply
24 ... 240 V AC/DC
Connection for
PTC sensor
Electrical
remote RESET
3RB2283-4AC1
3RB2383-4AA1
3RB2383-4AC1
Inputs
3RB2283-4AA1
Basic functions
Outputs
I () / I (+)
95/96 NC
05/06 NC
07/08 NO
--
No
Overload warning
Overload warning
3RB2985-2CA1
No
Overload warning
Overload warning
3RB2985-2CB1
No
3RB2985-2AA0
Analog signal
Overload warning
Overload warning
3RB2985-2AA1
Analog signal
Overload warning
Overload warning
3RB2985-2AB1
Analog signal
3RB2283-4AC1
3RB2383-4AA1
3RB2383-4AC1
97/98 NO
Siemens IC 10 AO 2014
7/57
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
3RB22, 3RB23 up to 630 A
for High-Feature applications
Function expansion modules for 3RB22 and 3RB23 overload relays (evaluation modules)
Size of
contactor
Version
For
overload
relays
DT
Article No.
3RB22,
3RB23
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2985-2AA0
1 unit
41F
3RB2985-2AA1
1 unit
41F
3RB2985-2AB1
1 unit
41F
Basic 1 GF modules2)
With internal ground-fault detection
and overload warning
3RB22,
3RB23
3RB2985-2CA1
1 unit
41F
Basic 2 GF modules2)
With internal ground-fault detection
and ground-fault signaling
3RB22,
3RB23
3RB2985-2CB1
1 unit
41F
Note:
Analog input modules, e.g. SM 331, must be configured for
4-wire measuring transducers. In this case the analog input
module must not supply current to the analog output of the
3RB22/3RB23 relay.
7/58
Siemens IC 10 AO 2014
1)
2)
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Current measuring modules for
3RB22, 3RB23
Overview
The current measuring modules are designed as system components for connecting to evaluation units 3RB22 and 3RB23.
Using these evaluation modules the motor current is measured
and the measured value sent to the evaluation unit for evaluation.
3RB2906-2JG1
Size of
contactor3)
3RB2956-2TG2
Rating for
three-phase
motor,
rated value4)
Current
setting value
of the
inverse-time
delayed
overload
release
Short-circuit
protection with
fuse, type of
coordination "2",
operational
class gG5)
kW
3RB2966-2WH2
For
overload
relays
DT
Article No.
3RB22,
3RB23
}
}
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2906-2BG1
1 unit
41G
3RB2906-2DG1
1 unit
41G
Sizes S00/S02)6)
S00/S0
0.09 1.1
0.3 3
20
1.1 11
2.4 25
63
5.5 45
10 100
315
3RB22,
3RB23
3RB2906-2JG1
1 unit
41G
11 90
20 200
315
3RB22,
3RB23
3RB2956-2TH2
1 unit
41G
3RB22,
3RB23
3RB2956-2TG2
1 unit
41G
3RB22,
3RB23
3RB2966-2WH2
1 unit
41G
Sizes S2/S32)6)
S2/S3
Size S61)6)
S6 with busbar connection
For mounting to S6 contactors with box terminals
Sizes S10/S121)
S10/S12 and size 14
(3TF68/ 3TF69)
37 450
63 630
800
Note:
The connecting cable between the current measuring module
and the evaluation module is not included in the scope of supply; please order separately.
1)
The current measuring modules with an Article No. ending with "2" are
designed for mounting onto contactor and stand-alone installation. For
3TF68/3TF69 contactors, direct mounting is not possible.
2)
The current measuring modules with an Article No. ending with "1" are
designed for mounting onto stand-alone installation.
3)
4)
Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
5)
6)
The modules with an Article No. with "G" in penultimate position are
equipped with a straight-through transformer.
Accessories
Size of
contactor
Version
For current
DT
measuring modules
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2987-2.
Length 0.1 m
(only for mounting of the
evaluation module directly onto
the current measuring module)
3RB29
3RB2987-2B
1 unit
41F
3RB29
3RB2987-2D
1 unit
41F
Siemens IC 10 AO 2014
7/59
3RB2906-2.G1
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Accessories for 3RB22, 3RB23
Overview
Overload relays for High-Feature applications
The following optional accessories are available for the 3RB22
and 3RB23 solid-state overload relays:
Sealable covers
Size
For overDT
load relays
--
3RB22,
3RB23
Length 100 mm
S6
3RB2956
Length 120 mm
S10/S12
3RB2966
Length 25 mm
S6
Length 30 mm
S10/S12
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RB2984-2
1 10 units
41F
3RT1956-4EA1
1 unit
41B
3RT1966-4EA1
1 unit
41B
3RB2956
3RT1956-4EA2
1 unit
41B
3RB2966
3RT1966-4EA2
1 unit
41B
S6
3RB2956
3RT1956-4EA3
1 unit
41B
S10/S12
3RB2966
3RT1966-4EA3
1 unit
41B
Up to 70 mm2
S61)
3RB2956
3RT1955-4G
1 unit
41B
Up to 120 mm2
S6
3RB2956
3RT1956-4G
1 unit
41B
Up to 240 mm2
S10/S12
3RB2966
3RT1966-4G
1 unit
41B
1 10 units
41H
100 10 units
41F
3RB2984-2
3RT1956-4EA1
3RT1956-4EA2
3RT195.-4G
3RB22,
3RB23
3RP1903
3RB2906
3RB1900-0B
3RP1903
S00 ...S3
3RB1900-0B
1)
7/60
Siemens IC 10 AO 2014
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Accessories for 3RB22, 3RB23
Version
Size
Color
DT
Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
1 unit
41B
41B
3RA2908-1A
Screwdrivers
For all SIRIUS
devices with
spring-type
terminals
Length approx.
200 mm,
3.0 mm x 0.5 mm
Titanium
gray/
black,
partially
insulated
Unit labeling
plates1)
For SIRIUS
devices
20 mm x 7 mm
Pastel
3RB2
turquoise
Main and
A
auxiliary
circuit
connection:
3RB2
3RA2908-1A
Blank labels
3RT1900-1SB20
NSB0_01429b
3RT1900-1SB20
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systemtechnik GmbH
(see Catalog IC 10, Chapter 16, "Appendix" "External Partners").
1)
Siemens IC 10 AO 2014
7/61
Siemens AG 2014
Overload Relays
SIRIUS 3RB2 Solid-State Overload Relays
Notes
7/62
Siemens IC 10 AO 2014
Siemens AG 2014
Price groups
PG 14O, 41B, 41D, 41E, 41F, 4N1
8/3
8/4
8/8
8/12
8/16
8/20
8/26
8/26
Introduction
SIRIUS 3RA1 load feeders
General data
3RA11 direct-on-line starters
For snapping onto standard mounting
rails or for screw fixing
For busbar systems
3RA12 reversing starters
For snapping onto standard mounting
rails or for screw fixing
For busbar systems
Accessories
Busbar accessories
3RV19 infeed systems
8/2
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
Siemens AG 2014
Overview
3RA11
3RA12
Article No.
Page
The 3RA1 fuseless load feeders consist of the 3RV1 motor starter protector and
the 3RT1 contactor.
The motor starter protector and contactor are prewired and mechanically
connected in pre-assembled assembly kits (link modules, wiring kits and
standard mounting rail or busbar adapters). The motor starter protector and
contactor are mechanically and electrically connected by means of the link
module.
4 sizes (S00, S0, S2, S3)
Can be supplied for direct-on-line start or reversing duty as
- complete unit or
- single devices for self-assembly
3RA11 direct-on-line starters
for snapping onto standard mounting rails or
for screw fixing
3RA11
8/4
3RA11
8/8
3RA12
8/12
3RA12
8/16
3RV19
8/26
8/2
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
3RA1 fuseless load feeders
Operating conditions
3RA1 load feeders are climate-proof. They are intended for use
in enclosed rooms in which no severe operating conditions
(such as dust, caustic vapors, hazardous gases) prevail.
Suitable covers must be provided for installation in dusty and
damp locations.
Width
mm
kW
S00
45
12
5.5
S0
45
25
11
S2
55
50
22
S3
70
100
45
Types of coordination
EN 60947-4-1 and IEC 60947-4-1 make a distinction between
two different types of coordination, which are designated type of
coordination "1" and type of coordination "2". Any short circuits
occur safely for both types of coordination. The only differences
concern the extent of the damage caused to the device by a
short circuit.
ToC
ToC
The SENTRON 3VL circuit breakers and the SIRIUS 3RT contactors can be used for fuseless load feeders >100 A. The corresponding distances from grounded or live parts, as detailed in
the technical specifications, must be observed.
More information and assignment tables for self-assembly
combinations for 400 V, 440 V, 480 V, 500 V, 550 V and 690 V see
the configuration manual "Configuring SIRIUS Selection Data
for Fuseless Load Feeders", see page 8/25.
Siemens IC 10 AO 2014
8/3
All 3RA1 fuseless load feeders described here are designed for
normal starting, in other words for overload tripping times of less
than 10 s (CLASS 10). At rated-load operating temperature the
tripping times are shorter, depending on the particular equipment and the setting range. The exact values can be derived
from the tripping characteristics of the motor starter protectors.
Siemens AG 2014
3RA1110
Size
3RA1120
Standard
three-phase
motor
4-pole at
400 V AC4)
Standard
output
P
Motor
current
I
(guide
value)
kW
3RA1130
Setting
range for
thermal
overload
release
DT
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1AP01
11-1AA00
+6)
A
A
A
A
A
A
A
A
A
A
A
3RA1110-0BA15-1AP0
3RA1110-0CA15-1AP0
3RA1110-0DA15-1AP0
3RA1110-0EA15-1AP0
3RA1110-0FA15-1AP0
3RA1110-0GA15-1AP0
3RA1110-0HA15-1AP0
3RA1110-0JA15-1AP0
3RA1110-0KA15-1AP0
3RA1110-1AA15-1AP0
3RA1110-1BA15-1AP0
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1AP00
21-1AA00
+6)
A
A
A
A
A
A
A
A
A
A
3RA1120-1CA24-0AP0
3RA1120-1DA24-0AP0
3RA1120-1EA24-0AP0
3RA1120-1FA24-0AP0
3RA1120-1GA24-0AP0
3RA1120-1HA24-0AP0
3RA1120-1JA26-0AP0
3RA1120-1KA26-0AP0
3RA1120-4AA26-0AP0
3RA1120-4BA26-0AP0
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
31-1AA00
+
32-1AA00
A
A
A
A
A
3RA1130-4DB34-0AP0
3RA1130-4EB34-0AP0
3RA1130-4FB35-0AP0
3RA1130-4GB36-0AP0
3RA1130-4HB36-0AP0
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1AP00
34-1AP00
35-1AP00
36-1AP00
44-1AP00
45-1AP00
46-1AP00
41-1AA00
+
42-1AA00
1)
2)
3)
4)
Selection depends on the concrete startup and rated data of the protected
motor.
5)
6)
Screw fixing with 1 push-in lug each per load feeder is possible
(see "Accessories for Direct-On-Line and Reversing Starters").
8/4
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
DT
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
S00
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1AP01
11-1AA00
+3)
A
A
A
A
A
A
A
A
3RA1110-1CA15-1AP0
3RA1110-1DA15-1AP0
3RA1110-1EA15-1AP0
3RA1110-1FA15-1AP0
3RA1110-1GA15-1AP0
3RA1110-1HA15-1AP0
3RA1110-1JA16-1AP0
3RA1110-1KA17-1AP0
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
18 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1AA00
+3)
A
A
A
A
3RA1120-4AA25-0AP0
3RA1120-4BA25-0AP0
3RA1120-4CA26-0AP0
3RA1120-4DA26-0AP0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S2
25-1AP00
26-1AP00
26-1AP00
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
3)
Screw fixing with 1 push-in lug each per load feeder is possible
(see "Accessories for Direct-On-Line and Reversing Starters").
S0
16-1AP01
17-1AP01
Siemens IC 10 AO 2014
8/5
Siemens AG 2014
3RA1110
Size
3RA1120
Standard
three-phase
motor
4-pole at
400 V AC3)
Standard
output
P
Motor
current
I
(guide
value)
kW
3RA1130
Setting
range for
thermal
overload
release
DT
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1BB41
11-1AA00
+5)
A
A
A
A
A
A
A
A
A
A
A
3RA1110-0BA15-1BB4
3RA1110-0CA15-1BB4
3RA1110-0DA15-1BB4
3RA1110-0EA15-1BB4
3RA1110-0FA15-1BB4
3RA1110-0GA15-1BB4
3RA1110-0HA15-1BB4
3RA1110-0JA15-1BB4
3RA1110-0KA15-1BB4
3RA1110-1AA15-1BB4
3RA1110-1BA15-1BB4
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1BB40
21-1BA00
+5)
A
A
A
A
A
A
A
A
A
A
3RA1120-1CA24-0BB4
3RA1120-1DA24-0BB4
3RA1120-1EA24-0BB4
3RA1120-1FA24-0BB4
3RA1120-1GA24-0BB4
3RA1120-1HA24-0BB4
3RA1120-1JA26-0BB4
3RA1120-1KA26-0BB4
3RA1120-4AA26-0BB4
3RA1120-4BA26-0BB4
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
31-1BA00
+
32-1AA00
A
A
A
A
A
3RA1130-4DB34-0BB4
3RA1130-4EB34-0BB4
3RA1130-4FB35-0BB4
3RA1130-4GB36-0BB4
3RA1130-4HB36-0BB4
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1BB40
34-1BB40
35-1BB40
36-1BB40
44-1BB40
45-1BB40
46-1BB40
41-1BA00
+
42-1AA00
1)
2)
3)
Selection depends on the concrete startup and rated data of the protected
motor.
4)
5)
Screw fixing with 1 push-in lug each per load feeder is possible
(see "Accessories for Direct-On-Line and Reversing Starters").
8/6
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
DT
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
S00
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1BB41
11-1AA00
+3)
A
A
A
A
A
A
A
A
3RA1110-1CA15-1BB4
3RA1110-1DA15-1BB4
3RA1110-1EA15-1BB4
3RA1110-1FA15-1BB4
3RA1110-1GA15-1BB4
3RA1110-1HA15-1BB4
3RA1110-1JA16-1BB4
3RA1110-1KA17-1BB4
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
18 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1BA00
+3)
A
A
A
A
3RA1120-4AA25-0BB4
3RA1120-4BA25-0BB4
3RA1120-4CA26-0BB4
3RA1120-4DA26-0BB4
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S2
25-1BB40
26-1BB40
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
3)
Screw fixing with 1 push-in lug each per load feeder is possible
(see "Accessories for Direct-On-Line and Reversing Starters").
S0
16-1BB41
17-1BB41
Siemens IC 10 AO 2014
8/7
Siemens AG 2014
3RA1110
3RA1120
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC3)
Standard
output
P
Motor
current
I
(guide
value)
kW
DT
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
0.14 0.2
0.18 0.25
0.22 0.32
0.28 0.4
0.35 0.5
0.45 0.63
0.55 0.8
0.7 1
0.9 1.25
1.1 1,6
1.4 2
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1AP01
3RA1911-1AA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
A
A
A
A
A
A
A
3RA1110-0B
3RA1110-0C
3RA1110-0D
3RA1110-0E
3RA1110-0F
3RA1110-0G
3RA1110-0H
3RA1110-0J
3RA1110-0K
3RA1110-1A
3RA1110-1B
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
1.8 2.5
2.2 3,2
2.8 4
3.5 5
4.5 6.3
5.5 8
7 10
9 12.5
11 16
14 20
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1AP00
3RA1921-1AA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
A
A
A
A
A
A
3RA1120-1C
3RA1120-1D
3RA1120-1E
3RA1120-1F
3RA1120-1G
3RA1120-1H
3RA1120-1J
3RA1120-1K
3RA1120-4A
3RA1120-4B
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@26-0AP0
@26-0AP0
@26-0AP0
@26-0AP0
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1AP00
34-1AP00
35-1AP00
36-1AP00
44-1AP00
45-1AP00
46-1AP00
3RA1931-1AA00
+
40 mm
8US1061-5FP08
or 60 mm
8US1261-5FP08
3RA1941-1AA00
C
D
1)
2)
3)
Selection depends on the concrete startup and rated data of the protected
motor.
8/8
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
DT
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.75
1.9
1.4 ... 2
3RV10
3RT10
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
1.8 2.5
2.2 3,2
2.8 4
3.5 5
4.5 6.3
5.5 8
7 10
9 12
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1AP01
7.5
7.5
11
11
15.5
15.5
22
22
11 16
14 20
17 22
18 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S0
S2
A
A
A
A
A
A
A
A
3RA1110-1C
3RA1110-1D
3RA1110-1E
3RA1110-1F
3RA1110-1G
3RA1110-1H
3RA1110-1J
3RA1110-1K
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@15-1AP0
@16-1AP0
@17-1AP0
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
3RA1921-1AA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
3RA1120-4A
3RA1120-4B
3RA1120-4C
3RA1120-4D
@25-0AP0
@25-0AP0
@26-0AP0
@26-0AP0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
16-1AP01
17-1AP01
25-1AP00
26-1AP00
40 mm
60 mm
1)
Selection depends on the concrete startup and rated data of the protected
motor.
Siemens IC 10 AO 2014
8/9
Siemens AG 2014
3RA1110
3RA1120
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC2)
Standard
output
P
Motor
current
I
(guide
value)
kW
DT
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1BB41
3RA1911-1AA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
A
A
A
A
A
A
A
3RA1110-0B
3RA1110-0C
3RA1110-0D
3RA1110-0E
3RA1110-0F
3RA1110-0G
3RA1110-0H
3RA1110-0J
3RA1110-0K
3RA1110-1A
3RA1110-1B
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1BB40
3RA1921-1BA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
A
A
A
A
A
A
3RA1120-1C
3RA1120-1D
3RA1120-1E
3RA1120-1F
3RA1120-1G
3RA1120-1H
3RA1120-1J
3RA1120-1K
3RA1120-4A
3RA1120-4B
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@26-0BB4
@26-0BB4
@26-0BB4
@26-0BB4
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1BB40
34-1BB40
35-1BB40
36-1BB40
3RA1931-1BA00
+
40 mm
8US1061-5FP08
or 60 mm
8US1261-5FP08
44-1BB40
45-1BB40
46-1BB40
3RA1941-1BA00
+
not available
C
D
1)
2)
Selection depends on the concrete startup and rated data of the protected
motor.
8/10
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
DT
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.75
1.9
1.4 ... 2
3RV10
3RT10
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1BB41
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
18 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S0
S2
A
A
A
A
A
A
A
A
3RA1110-1C
3RA1110-1D
3RA1110-1E
3RA1110-1F
3RA1110-1G
3RA1110-1H
3RA1110-1J
3RA1110-1K
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@15-1BB4
@16-1BB4
@17-1BB4
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
3RA1921-1BA00
+
40 mm
8US1051-5DM07
or 60 mm
8US1251-5DM07
A
A
A
A
3RA1120-4A
3RA1120-4B
3RA1120-4C
3RA1120-4D
@25-0BB4
@25-0BB4
@26-0BB4
@26-0BB4
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
16-1BB41
17-1BB41
25-1BB40
26-1BB40
40 mm
60 mm
1)
Selection depends on the concrete startup and rated data of the protected
motor.
Siemens IC 10 AO 2014
8/11
Siemens AG 2014
The motor starter protector and contactor are mechanically and electrically connected by means of the link
module
As from size S0 with standard mounting rail adapter2) for
mechanical reinforcement
Auxiliary switches3) on the motor starter protector and the
contactor can be easily fitted due to the modular system
Complete unit always with electrical and mechanical
interlock
3RA1210
3RA1220
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC4)
Standard
output
P
Motor
current
I
(guide
value)
kW
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RH2)5)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1AP02
11-1AA00
+
13-2A7)
A
A
A
A
A
A
A
A
A
A
A
3RA1210-0BA15-0AP0
3RA1210-0CA15-0AP0
3RA1210-0DA15-0AP0
3RA1210-0EA15-0AP0
3RA1210-0FA15-0AP0
3RA1210-0GA15-0AP0
3RA1210-0HA15-0AP0
3RA1210-0JA15-0AP0
3RA1210-0KA15-0AP0
3RA1210-1AA15-0AP0
3RA1210-1BA15-0AP0
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1AP00
21-1AA00
+
23-1B8)
A
A
A
A
A
A
A
A
A
A
3RA1220-1CB24-0AP0
3RA1220-1DB24-0AP0
3RA1220-1EB24-0AP0
3RA1220-1FB24-0AP0
3RA1220-1GB24-0AP0
3RA1220-1HB24-0AP0
3RA1220-1JB26-0AP0
3RA1220-1KB26-0AP0
3RA1220-4AB26-0AP0
3RA1220-4BB26-0AP0
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1AP00
34-1AP00
35-1AP00
36-1AP00
44-1AP00
45-1AP00
46-1AP00
31-1AA00
+
33-1B8)
41-1AA00
+
43-1B8)
1)
2)
Assembly kit for standard mounting rail adapter also suitable for screw
fixing.
3)
4)
Selection depends on the concrete startup and rated data of the protected
motor.
5)
6)
7)
Wiring kit necessary: for screw fixing with 1 push-in lug each per load
feeder (see "Accessories for Direct-On-Line and Reversing Starters").
8)
8/12
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RH2)3)
Fuseless
load feeders
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1AP02
11-1AA00
+
13-2A5)
A
A
A
A
A
A
A
A
3RA1210-1CA15-0AP0
3RA1210-1DA15-0AP0
3RA1210-1EA15-0AP0
3RA1210-1FA15-0AP0
3RA1210-1GA15-0AP0
3RA1210-1HA15-0AP0
3RA1210-1JA16-0AP0
3RA1210-1KA17-0AP0
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
20 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1AA00
+
23-1B6)
A
A
A
A
3RA1220-4AB25-0AP0
3RA1220-4BB25-0AP0
3RA1220-4CB26-0AP0
3RA1220-4DB26-0AP0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S2
16-1AP02
17-1AP02
25-1AP00
26-1AP00
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
Assembly kit for standard mounting rail adapter also suitable for screw
fixing.
3)
4)
5)
Wiring kit necessary: for screw fixing with 1 push-in lug each per load
feeder (see "Accessories for Direct-On-Line and Reversing Starters").
6)
S0
Siemens IC 10 AO 2014
8/13
Siemens AG 2014
The motor starter protector and contactor are mechanically and electrically connected by means of the link
module
As from size S0 with standard mounting rail adapter1) for
mechanical reinforcement
Auxiliary switches2) on the motor starter protector and the
contactor can be easily fitted due to the modular system
Complete unit always with electrical and mechanical
interlock
3RA1210
3RA1220
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC3)
Standard
output
P
Motor
current
I
(guide
value)
kW
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RH4)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1BB42
11-1AA00
+
13-2A6)
A
A
A
A
A
A
A
A
A
A
A
3RA1210-0BA15-0BB4
3RA1210-0CA15-0BB4
3RA1210-0DA15-0BB4
3RA1210-0EA15-0BB4
3RA1210-0FA15-0BB4
3RA1210-0GA15-0BB4
3RA1210-0HA15-0BB4
3RA1210-0JA15-0BB4
3RA1210-0KA15-0BB4
3RA1210-1AA15-0BB4
3RA1210-1BA15-0BB4
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1BB40
21-1BA00
+
23-1B7)
A
A
A
A
A
A
A
A
A
A
3RA1220-1CB24-0BB4
3RA1220-1DB24-0BB4
3RA1220-1EB24-0BB4
3RA1220-1FB24-0BB4
3RA1220-1GB24-0BB4
3RA1220-1HB24-0BB4
3RA1220-1JB26-0BB4
3RA1220-1KB26-0BB4
3RA1220-4AB26-0BB4
3RA1220-4BB26-0BB4
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1BB40
34-1BB40
35-1BB40
36-1BB40
44-1BB40
45-1BB40
46-1BB40
31-1BA00
+
33-1B7)
41-1BA00
+
43-1B7)
1)
Assembly kit for standard mounting rail adapter also suitable for screw
fixing.
2)
3)
Selection depends on the concrete startup and rated data of the protected
motor.
4)
5)
6)
Wiring kit necessary: Screw fixing with 1 push-in lug each per load feeder
is possible (see "Accessories for Direct-On-Line and Reversing Starters").
7)
8/14
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RH2)3)
Fuseless
load feeders
Article No.
ToC
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1BB42
11-1AA00
+
13-2A5)
A
A
A
A
A
A
A
A
3RA1210-1CA15-0BB4
3RA1210-1DA15-0BB4
3RA1210-1EA15-0BB4
3RA1210-1FA15-0BB4
3RA1210-1GA15-0BB4
3RA1210-1HA15-0BB4
3RA1210-1JA16-0BB4
3RA1210-1KA17-0BB4
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
20 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1BA00
+
23-1B6)
A
A
A
A
3RA1220-4AB25-0BB4
3RA1220-4BB25-0BB4
3RA1220-4CB26-0BB4
3RA1220-4DB26-0BB4
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S2
16-1BB42
17-1BB42
25-1BB40
26-1BB40
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
Assembly kit for standard mounting rail adapter also suitable for screw
fixing.
3)
4)
5)
Wiring kit necessary: Screw fixing with 1 push-in lug each per load feeder
is possible (see "Accessories for Direct-On-Line and Reversing Starters").
6)
S0
Siemens IC 10 AO 2014
8/15
Siemens AG 2014
The motor starter protector and contactor are mechanically and electrically connected by means of the link
module
Auxiliary switches2) on the motor starter protector and the
contactor can be easily fitted due to the modular system
Complete unit always with electrical and mechanical
interlock
3RA1210
3RA1220
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC3)
Standard
output
P
Motor
current
I
(guide
value)
kW
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RS4)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1AP02
11-1AA00
+
40 mm
13-1C
or 60 mm
13-1D
A
A
A
A
A
A
A
A
A
A
A
3RA1210-0B
3RA1210-0C
3RA1210-0D
3RA1210-0E
3RA1210-0F
3RA1210-0G
3RA1210-0H
3RA1210-0J
3RA1210-0K
3RA1210-1A
3RA1210-1B
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1AP00
21-1AA00
+
40 mm
23-1C5)
or 60 mm
23-1D5)
A
A
A
A
A
A
A
A
A
A
3RA1220-1C
3RA1220-1D
3RA1220-1E
3RA1220-1F
3RA1220-1G
3RA1220-1H
3RA1220-1J
3RA1220-1K
3RA1220-4A
3RA1220-4B
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@24-0AP0
@26-0AP0
@26-0AP0
@26-0AP0
@26-0AP0
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1AP00
35-1AP00
36-1AP00
31-1AA00
+
40 mm
33-1C5)
or 60 mm
33-1D5)
44-1AP00
45-1AP00
46-1AP00
41-1AA00
+
not available
34-1AP00
C
D
1)
2)
3)
Selection depends on the concrete startup and rated data of the protected
motor.
4)
5)
8/16
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RS2)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
S00
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1AP02
11-1AA00
+
40 mm
13-1C
or 60 mm
13-1D
A
A
A
A
A
A
A
A
3RA1210-1C
3RA1210-1D
3RA1210-1E
3RA1210-1F
3RA1210-1G
3RA1210-1H
3RA1210-1J
3RA1210-1K
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@15-0AP0
@16-0AP0
@17-0AP0
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
20 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1AA00
+
40 mm
23-1C3)
or 60 mm
23-1D3)
A
A
A
A
3RA1220-4A
3RA1220-4B
3RA1220-4C
3RA1220-4D
@25-0AP0
@25-0AP0
@26-0AP0
@26-0AP0
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S0
S2
16-1AP02
17-1AP02
25-1AP00
26-1AP00
40 mm
60 mm
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
3)
Siemens IC 10 AO 2014
8/17
Siemens AG 2014
The motor starter protector and contactor are mechanically and electrically connected by means of the link
module
Auxiliary switches1) on the motor starter protector and the
contactor can be easily fitted due to the modular system
Complete unit always with electrical and mechanical
interlock
3RA1210
3RA1220
Size
Setting
range for
thermal
overload
release
Standard
three-phase
motor
4-pole at
400 V AC2)
Standard
output
P
Motor
current
I
(guide
value)
kW
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RS3)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
3RA19
0.06
0.06
0.09
0.09
0.12
0.18
0.18
0.25
0.37
0.55
0.75
0.2
0.2
0.3
0.3
0.4
0.6
0.6
0.85
1.1
1.5
1.9
11-0BA10
11-0CA10
11-0DA10
11-0EA10
11-0FA10
11-0GA10
11-0HA10
11-0JA10
11-0KA10
11-1AA10
11-1BA10
15-1BB42
11-1AA00
+
40 mm
13-1C
or 60 mm
13-1D
A
A
A
A
A
A
A
A
A
A
A
3RA1210-0B
3RA1210-0C
3RA1210-0D
3RA1210-0E
3RA1210-0F
3RA1210-0G
3RA1210-0H
3RA1210-0J
3RA1210-0K
3RA1210-1A
3RA1210-1B
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
S0
0.75
1.1
1.5
1.5
2.2
3
4
5.5
7.5
7.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
15.5
15.5
21-1CA10
21-1DA10
21-1EA10
21-1FA10
21-1GA10
21-1HA10
21-1JA10
21-1KA10
21-4AA10
21-4BA10
24-1BB40
21-1BA00
+
40 mm
23-1C4)
or 60 mm
23-1D4)
A
A
A
A
A
A
A
A
A
A
3RA1220-1C
3RA1220-1D
3RA1220-1E
3RA1220-1F
3RA1220-1G
3RA1220-1H
3RA1220-1J
3RA1220-1K
3RA1220-4A
3RA1220-4B
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@24-0BB4
@26-0BB4
@26-0BB4
@26-0BB4
@26-0BB4
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
41D
41D
11
15
18.5
22
22
22
29
35
41
41
18 ... 25
22 ... 32
28 ... 40
36 ... 45
40 ... 50
31-4DA10
31-4EA10
31-4FA10
31-4GA10
31-4HA10
30
37
45
45
55
66
80
80
45 ... 63
57 ... 75
70 ... 90
80 ... 100
41-4JA10
41-4KA10
41-4LA10
41-4MA10
3RV10
S00
S2
S3
26-1BB40
35-1BB40
36-1BB40
31-1BA00
+
40 mm
33-1C4)
or 60 mm
33-1D4)
44-1BB40
45-1BB40
46-1BB40
41-1BA00
+
not available
34-1BB40
C
D
1)
2)
Selection depends on the concrete startup and rated data of the protected
motor.
3)
4)
8/18
Siemens IC 10 AO 2014
Siemens AG 2014
Standard
three-phase
motor
4-pole at
400 V AC1)
Standard
output
P
Motor
current
I
(guide
value)
kW
Setting
range for
thermal
overload
release
Motor starter + 2
protectors
contactors
DT
+ Link module
+ Assembly kit
RS2)
Fuseless
load feeders
ToC
Article No.
PU
(UNIT,
SET, M)
PS*
PG
Price
per PU
0.75
1.9
1.4 ... 2
3RV10
3RT10
3RA19
S00
0.75
1.1
1.5
1.5
2.2
3
4
5.5
1.9
2.7
3.6
3.6
4.9
6.5
8.5
11.5
11-1CA10
11-1DA10
11-1EA10
11-1FA10
11-1GA10
11-1HA10
11-1JA10
11-1KA10
15-1BB42
11-1AA00
+
40 mm
13-1C
or 60 mm
13-1D
A
A
A
A
A
A
A
A
3RA1210-1C
3RA1210-1D
3RA1210-1E
3RA1210-1F
3RA1210-1G
3RA1210-1H
3RA1210-1J
3RA1210-1K
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@15-0BB4
@16-0BB4
@17-0BB4
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
41D
41D
41D
41D
7.5
7.5
11
11
15.5
15.5
22
22
11 ... 16
14 ... 20
17 ... 22
20 ... 25
21-4AA10
21-4BA10
21-4CA10
21-4DA10
21-1BA00
+
40 mm
23-1C3)
or 60 mm
23-1D3)
A
A
A
A
3RA1220-4A
3RA1220-4B
3RA1220-4C
3RA1220-4D
@25-0BB4
@25-0BB4
@26-0BB4
@26-0BB4
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41D
41D
41D
41D
15
18.5
22
29
35
41
22 ... 32
28 ... 40
36 ... 45
...
S0
S2
16-1BB42
17-1BB42
25-1BB40
26-1BB40
40 mm
60 mm
1)
Selection depends on the concrete startup and rated data of the protected
motor.
2)
3)
Siemens IC 10 AO 2014
8/19
Siemens AG 2014
DT
Article No.
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
Size
MSPs/circuit breakers1)
Auxiliary switches
1 CO contact }
1 NO + 1 NC }
3RV1901-1D
3RV1901-1E
1
1
1 unit
1 unit
41E
41E
Laterally mountable 1 NO + 1 NC
3RV1901-1A
1 unit
41E
--
Undervoltage releases
50 Hz 230 V AC
3RV1902-1AP0
1 unit
41E
--
Shunt releases
50 Hz 230 V AC
3RV1902-1DP0
1 unit
41E
S00 ...S3
--
Transverse
Transverse
S00 ...S3
--
S00 ...S3
S00 ...S3
3RV1901-1E
3RV1901-1A
3RV1902-1...
Contactors2)
3RH1911-1BA..
--
S00
1-pole
1 NO
1 NC
}
}
3RH1911-1BA10
3RH1911-1BA01
1
1
1 unit
1 unit
41B
41B
--
S00
2-pole
1 NO + 1 NC
2 NO
}
}
3RH1911-1MA11
3RH1911-1MA20
1
1
1 unit
1 unit
41B
41B
--
S0 ...S3
1 NO + 1 NC
2 NO
2 NC
}
}
}
3RH1921-1MA11
3RH1921-1MA20
3RH1921-1MA02
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
--
S00
4-pole
2 NO + 2 NC
3RH1911-1FA22
1 unit
41B
--
S0 ...S3
1-pole
1 NO
1 NC
}
}
3RH1921-1CA10
3RH1921-1CA01
1
1
1 unit
1 unit
41B
41B
--
S0 ...S3
4-pole
2 NO + 2 NC
3RH1921-1FA22
1 unit
41B
3RH1911-1F...
1)
2)
8/20
Siemens IC 10 AO 2014
Siemens AG 2014
Article No.2)
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
Type
3RT1.
Varistor
RC elements
3RT1916-1DG00
24 ... 48 V AC
24 ... 70 V DC
3RT1916-1BB00
1 unit
41B
3RT1916-1BD00
1 unit
41B
24 ... 48 V AC
24 ... 70 V DC
3RT1916-1CB00
1 unit
41B
3RT1916-1CD00
1 unit
41B
3RT1.
Noise suppression
diodes
12 ... 250 V DC
3RT1916-1DG00
1 unit
41B
3RT1.
Diode assemblies
(diode and Zener diode)
for DC operation and
short break times
12 ... 250 V DC
3RT1916-1EH00
1 unit
41B
24 ... 48 V AC
24 ... 70 V DC
3RT1926-1BB00
1 unit
41B
3RT1926-1BD00
1 unit
41B
24 ... 48 V AC
24 ... 70 V DC
3RT1926-1CB00
1 unit
41B
3RT1926-1CD00
1 unit
41B
24 V DC
3RT1926-1TR00
1 unit
41B
30 ... 250 V DC
3RT1926-1TS00
1 unit
41B
24 ... 48 V AC
24 ... 70 V DC
3RT1926-1BB00
1 unit
41B
3RT1926-1BD00
1 unit
41B
24 ... 48 V AC
24 ... 70 V DC
3RT1936-1CB00
1 unit
41B
3RT1936-1CD00
1 unit
41B
24 V DC
3RT1936-1TR00
1 unit
41B
30 ... 250 V DC
3RT1936-1TS00
1 unit
41B
Size S0
3RT102
3RT102
Varistor
RC elements
3RT1926-1B.00
3RT102
Diode assemblies
For DC operation and short break times
Can be plugged in
at bottom
Sizes S2 and S3
For fitting onto the coil terminals at top or
bottom
3RT103,
3RT104
3RT103,
3RT104
3RT103,
3RT104
3RT1936-1C.00
Varistor
RC elements
Diode assemblies
For DC operation and short break times
Can be plugged in
at bottom
1)
Can be used for AC operation for 50/60 Hz. Please inquire about further
voltages.
2)
For packs of 10 or 5 units, "-Z" and order code "X90" must be added to the
Article No.
Siemens IC 10 AO 2014
8/21
Siemens AG 2014
DT
Article No.
}
}
}
}
}
}
}
}
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
3RA1911-1AA00
3RA1921-1DA00
3RA1921-1AA00
3RA1931-1AA00
3RA1941-1AA00
3RA1921-1BA00
3RA1931-1BA00
3RA1941-1BA00
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
41B
41B
41B
41B
}
}
}
}
}
}
}
}
3RA1911-1A
3RA1921-1D
3RA1921-1A
3RA1931-1A
3RA1941-1A
3RA1921-1B
3RA1931-1B
3RA1941-1B
1
1
1
1
1
1
1
1
10 units
10 units
10 units
5 units
5 units
10 units
5 units
5 units
41B
41B
41B
41B
41B
41B
41B
41B
}
}
3RA1911-2FA00
3RA1921-2FA00
1
1
1 unit
1 unit
41B
41B
}
}
3RA1911-2F
3RA1921-2F
1
1
10 units
10 units
41B
41B
}
}
}
}
3RA1913-2A
3RA1923-2A
3RA1933-2A
3RA1943-2A
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
Wye-delta starting
Electrical and mechanical link for A
three contactors of same size
}
}
}
3RA1913-2B
3RA1923-2B
3RA1933-2B
3RA1943-2B
1
1
1
1
1 unit
1 unit
1 unit
1 unit
41B
41B
41B
41B
Size
Link modules
Electrical and mechanical link
between motor starter protector
and contactor.
Single-unit packaging
Actuating voltage of contactor
3RA1911-1A
S00
S0
S0
S2
S3
S0
S2
S3
3RA1921-1A
S00
S00
S0
S2
S3
S0
S2
S3
AC and DC
AC
DC
Multi-unit packaging
Actuating voltage of contactor
3RA1931-1A
S00
S0
S0
S2
S3
S0
S2
S3
S00
S00
S0
S2
S3
S0
S2
S3
AC and DC
Screw
terminals
Springtype
terminals
AC
DC
Single-unit packaging
Actuating voltage of contactor
S00
S0
S00
S00
AC and DC
Multi-unit packaging
3RA1921-2FA00
S00
S00
--
S00
S0
S2
S3
--
S00
S0
S2
S3
AC and DC
Wiring kits
3RA1913-2A
Reversing duty
Electrical and mechanical link for
reversing contactors.
Can be combined with link
module.
For size S00:
optionally with integrated electrical and mechanical interlocking.
For sizes S0 to S3:
Mechanical locking device must
be ordered separately.
3RT1926-4RD01
--
S00
Size S00,
rated operational current Ie
at AC-3/400 V: 20 A
3RT1916-4RD01
1 unit
41B
--
S0
Size S0,
rated operational current Ie
at AC-3/400 V: 25 A
3RT1926-4RD01
1 unit
41B
--
S00, S0
3RT1900-4RE01
1 unit
41B
3RT1900-4RE01
8/22
Siemens IC 10 AO 2014
Siemens AG 2014
DT
Article No.
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
Size
Size
--
3RA1924-2B
1 unit
41B
--
3RA1923-3B
1 unit
41B
}
}
}
3RA1922-1AA00
3RA1932-1AA00
3RA1942-1AA00
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
Mechanical interlocks
3RA1924-2B
3RA1923-3B
S00, S0
S2
S3
S00, S0
S2
S3
S00, S0
S2
S3
}
}
}
3RA1922-1A
3RA1932-1A
3RA1942-1A
1
1
1
5 units
5 units
5 units
41B
41B
41B
S00 ...S3
S00 ...S3
3RA1902-1B
10 units
41B
3RA1923-1B
3RA1933-1B
3RA1943-1B
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
3RA1932 3RA1922
Side modules
3RA1902
Assembly kits (RH) for reversing duty for standard mounting rails
S0
S2
S3
S0
S2
S3
3RA1933-1B
Siemens IC 10 AO 2014
8/23
Multi-unit packaging
Siemens AG 2014
DT
Article No.
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
Size
--
Link modules,
spring-type terminals
Electrical connection between
motor starter protector and
contactor
(1 pack = 10 units)
3RA1911-2A
10 units
41B
S00
--
Link modules,
}
spring-type terminals with
mechanical connections
Mechanical and electrical
connection between motor starter
protector and contactor
(1 pack = 10 units)
3RA1911-2E
10 units
41B
--
3RA1922-1L
5 units
41B
--
Busbar adapters
}
45 mm wide,
}
182 mm long,
adapted for motor starter
protectors with spring-type
terminals.
If there is an additional contactor,
a further standard mounting rail
must be fitted.
8US1051-5CM47
1 unit
14O
8US1251-5CM47
1 unit
14O
8US1998-7CA15
10 units
14O
100
10 units
41F
3RA1911-2A
+ 8US1051-5CM47
--
--
--
3RA1911-2E
3RB1900-0B
3RB1900-0B
Busbar adapters
Busbar
center-tocenter
clearance
mm
S00, S0
S00, S0
45 mm wide,
182 mm long
for busbars
40
60
}
}
8US1051-5DM07
8US1251-5DM07
1
1
1 unit
1 unit
14O
14O
S2
S2
55 mm wide,
242 mm long
including screw and
spacer
40
60
}
}
8US1061-5FP08
8US1261-5FP08
1
1
1 unit
1 unit
14O
14O
8US1251-5DM07
Device holders
S00, S0
S00, S0
}
}
8US1050-5AM00
8US1250-5AM00
1
1
1 unit
1 unit
14O
14O
S0
S0
55 mm wide,
182 mm long
40
60
}
}
8US1060-5AM00
8US1260-5AM00
1
1
1 unit
1 unit
14O
14O
S2
S2
55 mm wide,
242 mm long
including screw and
spacer
60
8US1260-5AP00
1 unit
14O
8US1250-5AM00
8/24
Siemens IC 10 AO 2014
Siemens AG 2014
Size
--
--
DT
Article No.
Price
per PU
PU (UNIT,
SET, M)
PS*
PG
8US1998-2BM00
4 units
14O
A
A
3RA1913-1C
3RA1923-1C
1
1
1 unit
1 unit
41B
41B
A
A
A
3RA1913-1D
3RA1923-1D
3RA1933-1D
1
1
1
1 unit
1 unit
1 unit
41B
41B
41B
Side modules
Including connecting wedges,
for widening busbar adapters or
device holders, 13.5 mm wide,
182 mm long
8US1998-2BM00
S00
S0
S00, S0
S0
S2
S00
S0
S2
Consisting of
40
wiring kit, busbar
adapter, device
60
holder, and side module. Link modules and
mechanical locking
devices to be ordered
separately.
Only for size S00 is
mechanical interlocking always included.
--
--
8US1998-1AA00
8US1998-1AA00
100
100 units
14O
S00, S0
8US1998-8AM07
1 unit
14O
--
S00, S0
8US1998-1BA00
100
100 units
14O
--
S00, S0
8US1998-1CA00
100
20 units
14O
PS*
PG
8US1251-5DM07 with
8US1998-8AM07
Spacers
8US1998-1BA00
Screw holders
8US1998-1CA00
Version
DT
Article No.
Price
per PU
PU (UNIT,
SET, M)
Documentation
Configuration Manual 1)
"SIRIUS Configuration Selection Data for Load
Feeders in Fuseless Designs"
More information and assignment tables for
self-assembly combinations for 400 V, 440 V, 480 V,
500 V, 550 V and 690 V
1)
http://support.automation.siemens.com/WW/view/en/40625241/0
Siemens IC 10 AO 2014
8/25
Connecting wedges
Siemens AG 2014
Overview
Insulated three-phase busbar system
Three-phase busbar systems provide an easy, time-saving and
clearly arranged means of feeding 3RA1 load feeders with
screw terminals. Different versions are available for sizes S00,
S0 and S2 and can also be used for the various different types
of motor starter protectors.
The busbars are suitable for between 2 and 5 feeders. However,
any kind of extension is possible by clamping the tags of an additional busbar (rotated by 180) underneath the terminals of the
respective last motor starter protector.
A combination of feeders of different sizes is possible only with
sizes S00 and S0. Connecting pieces are available for this purpose. The motor starter protectors are supplied by appropriate
infeed terminals.
Busbar adapters for busbar systems with 40 mm center-to-center clearance are suitable for copper busbars with a width of
12 mm to 15 mm, while those with 60 mm center-to-center
clearance are suitable for copper busbars with a width of 12 mm
to 30 mm. The busbars can be 4 to 5 mm or 10 mm thick.
The feeders are snapped onto the adapter and connected on
the line side. This prepared unit is then plugged directly onto the
busbar system, and is thus connected both mechanically and
electrically at the same time.
Selection and ordering data see Chapter 7 "Protection Equipment" "SIRIUS 3RV1 Motor Starter Protectors/Circuit Breakers
up to 100 A" "Busbar Accessories".
3RV1915-5A
3RV1915-1CB
NSB0_01073d
rotated
by 180
3RV1915-5B
3RV1915-6AB
3RV1915-1AB
SIRIUS motor starter protectors and load feeders with busbar adapters
snapped onto busbars
3RV1915-6AB
The three-phase busbar systems are finger-safe. They are designed for any short-circuit stress which can occur at the output
side of connected motor starter protectors.
The three-phase busbar systems can also be used to construct
"Type E Starters" of size S0 or S2 according to UL/CSA. Special
infeed terminals must be used for this purpose however.
Selection and ordering data see Chapter 7 "Protection Equipment" "SIRIUS 3RV1 Motor Starter Protectors/Circuit Breakers
up to 100 A" "Busbar Accessories".
Busbar adapters for 40 mm and 60 mm systems
The load feeders are mounted directly with the aid of busbar
adapters on busbar systems with 40 mm and 60 mm center-tocenter clearance in order to save space and to reduce infeed
times and costs.
8/26
Siemens IC 10 AO 2014
SIRIUS 3RV19 infeed systems with three 3RA1110 load feeders and two
3RA1120 load feeders
Siemens AG 2014
9/3
9/4
9/4
9/4
9/2
Siemens
Siemens
IC 10
ICAO
10 AO
2014
2014
Siemens AG 2014
Overview
3RE10
Article No.
Page
3RE10
9/4
9/4
Accessories
Molded-plastic enclosure, degree of protection IP65, for direct-on-line and reversing 3RE19
starters
9/4
9/2
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Reversing starters
The reversing starters are available in two sizes:
Size S00 is suitable for three-phase motors up to 5.5 kW with
400 V AC and a maximum rated motor current of 12 A. The
starters are available in the following two versions:
- Molded-plastic enclosure for reversing starters including
contactor assembly in this case the overload relay must be
selected and ordered according to the rated motor current.
- Molded-plastic enclosure for reversing starters (without
contactor assembly) in this case the contactor assembly,
auxiliary switch and overload relay must be selected and
ordered separately.
Size S0 is suitable for three-phase motors up to 11 kW with
400 V AC and a maximum rated motor current of 25 A. The
starters are available in the following version:
- Molded-plastic enclosure for direct-on-line starters (without
contactor assembly) in this case the contactor assembly,
auxiliary switch and overload relay must be selected and
ordered separately.
Benefits
The 3RE1 encapsulated starters are available as direct-on-line
starters and as reversing starters.
Direct-on-line starters
The direct-on-line starters are available in three sizes:
Size S00 is suitable for three-phase motors up to 5.5 kW with
400 V AC and a maximum rated motor current of 12 A. The
starters are available in the following two versions:
- Molded-plastic enclosure for direct-on-line starters including
contactor in this case the overload relay must be selected
and ordered according to the rated motor current.
- Molded-plastic enclosure for direct-on-line starters (without
contactor) in this case the contactor and overload relay
must be selected and ordered separately.
Size S0 is suitable for three-phase motors up to 11 kW with
400 V AC and a maximum rated motor current of 25 A. The
starters are available in the following two versions:
- Molded-plastic enclosure for direct-on-line starters including
contactor in this case the overload relay must be selected
and ordered according to the rated motor current.
- Molded-plastic enclosure for direct-on-line starters (without
contactor) in this case the contactor, auxiliary switch and
overload relay must be selected and ordered separately.
Size S2 is suitable for three-phase motors up to 22 kW with
400 V AC and a maximum rated motor current of 50 A. The
starters are available in the following version:
- Molded-plastic enclosure for direct-on-line starters (without
contactor) in this case the contactor, auxiliary switch and
overload relay must be selected and ordered separately.
Application
The 3RE1 encapsulated starters are used for switching and for
the inverse-time delayed protection of load feeders up to 22 kW
at 400 V AC.
The starters are available as direct-on-line starters for motors
with a single direction of rotation and as reversing starters for
motors with two directions of rotation.
Siemens IC 10 AO 2014
9/3
Siemens AG 2014
Rated data
Utilization category
AC-2/AC-3
Tu: up to + 35 C
Operational
current Ie
at 400 V
Output of
three-phase
motors at
400 V/50 Hz
kW
Article No.
At Hz
PU (UNIT,
SET, M)
PS*
PG
Price
per PU
12
5.5
230 AC
400 AC
50 / 60
50 / 60
B
B
3RE1010-8XC17-0AP0
3RE1010-8XC17-0AV0
1
1
1 unit
1 unit
41B
41B
S0
17
7.5
230 AC
400 AC
50
50
B
B
3RE1020-8XC25-0AP0
3RE1020-8XC25-0AV0
1
1
1 unit
1 unit
41B
41B
25
11
230 AC
400 AC
50
50
B
B
3RE1020-8XC26-0AP0
3RE1020-8XC26-0AV0
1
1
1 unit
1 unit
41B
41B
50 / 60
50 / 60
B
B
3RE1310-8XC17-0AP0
3RE1310-8XC17-0AV0
1
1
1 unit
1 unit
41B
41B
Price PU (UNIT,
per PU
SET, M)
PS*
PG
3RE1010
12
5.5
230 AC
400 AC
3RE1310
Version
For
contactor
Overload
relay
DT Article No.
Size
S00
3RE1913-1CB1
1 unit
41B
S0
3RE1923-1CB2
1 unit
41B
S2
3RE1933-1CB3
1 unit
41B
S00/S0
3RE1913-2CB3
1 unit
41B
3RE1923-1CB2
3RE1923-2CB3
9/4
Siemens IC 10 AO 2014
11
Siemens AG 2014
Safety Technology
Price groups
PG 41B, 41H, 41L
Introduction
11/3
11/5
11/10
11/13
11/16
11/18
11
11/2
Siemens IC 10 AO 2014
Siemens AG 2014
Safety Technology
Introduction
Overview
Article No.
Page
3TK282,
3TK283
11/5
3TK284
11/10
3TK285
11/13
3TK2810
11/16
3TK2841-1BB40
3TK2810-1BA41
Connection methods
The safety relays can be delivered with screw terminals or
spring-type terminals.
Screw terminals
Spring-type terminals (push-in)
11
11/2
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
SIRIUS safety relays are the key modules of a consistent and
cost-effective safety chain. Be it EMERGENCY-STOP disconnection, protective door monitoring or the protection of presses or
punches with SIRIUS safety relays every safety application can
be implemented to optimum effect in terms of engineering and
price.
SIRIUS safety relays provide numerous safety-related functions:
Monitoring the safety functions of sensors
Monitoring the sensor leads
Monitoring the correct operation of the safety relay
Monitoring actuators for standstill
Safety-oriented disconnection when dangers arise
Depending on the version of the device, SIRIUS safety relays
satisfy the most stringent requirements (PL e) of
EN ISO 13849-1 and achieve the highest Safety Integrity Level
(SIL 3) according to IEC 61508.
SIRIUS 3TK28 safety relay
3TK28 Safety Relays
With relay enabling circuits
Basic units
Basic units
tv
Expansion
units
Two-hand
Basic units
control units
Basic units
tv
Multifunction units
Basic units
Expansion
units
Expansion
units tv
Standstill
monitors
Overspeed
monitors
3TK2820
3TK2826
3TK2830
3TK2834
3TK2842
3TK2845
3TK2850
3TK2856
3TK2857
3TK2810-0
3TK2810-1
3TK2821
3TK2827
3TK2822
3TK2828
3TK2840
3TK2841
3TK2851
3TK2852
3TK2823
3TK2853
3TK2824
3TK2825
3TK2826
See page 11/5
Note:
11
Siemens IC 10 AO 2014
11/3
Siemens AG 2014
Benefits
General
Can be used for all safety applications thanks to compliance
with the highest safety requirements (PL e according to
EN ISO 13849-1 or SIL 3 according to IEC 61508)
Suitable for use all over the world through compliance with all
globally established certifications
Compact, service-proven SIRIUS design creates more space
in the control cabinet
Flexible connectability and expandability make subsequent
changes easy
Removable terminals for greater plant availability
Yellow front plate clearly identifies the device as an item of
safety technology
Sensor cable up to 2 000 m long enables use in large-scale
plants
Application
SIRIUS safety relays are used mainly in autonomous safety
applications which are not connected to a safety-oriented bus
system.
Their function here is to evaluate the sensors and the safetyoriented shutdown of hazards. Also they check and monitor the
sensors, actuators and safety-oriented functions of the safety
relay.
More information
Manual "SIRIUS 3TK28 Safety Relays", see
http://support.automation.siemens.com/WW/view/en/58843445.
System manual "3TK2810-1 Safety-Oriented Overspeed
Monitors" see
http://support.automation.siemens.com/WW/view/en/43707376.
11
11/4
Siemens IC 10 AO 2014
Relay outputs
Different voltages can be switched through the floating
contacts
Higher currents can be switched with relay contacts
Solid-state outputs
Wear-free
Suitable for operation in fast switching applications
Insensitive to vibrations and dirt
Good electrical endurance
Microprocessor systems
Flexible use thanks to many different integrated functions
Easy parameterization using DIP switches on the front
High functional reliability based on extensive monitoring
functions
Operated by the machine control system
Also connection of non-contact sensors
(light arrays, light barriers etc.)
Siemens AG 2014
Overview
Benefits
General
Compact design
Floating safe outputs
3TK2834 safety relay also suitable for press and punch
controls
Can be used up to an ambient temperature of max. 70 C
3TK2826 safety relays
Connection of all common sensor types
Many functions available in just one device
Status indications
Extended diagnostic capabilities
Approvals (EN ISO 13849-1, IEC 61508, UL/CSA)
Signaling of disconnect faults in the actuator circuit
Floating outputs
Wide-range device
Sensor condition saved in the event of voltage failure
11
Without crossover
monitoring
NC/NO evaluation
2 x 1-channel
Debounce time for
sensor inputs 50 ms
DIP
switch
No.
ON
Switching mat
operation
NC/NC evaluation
1 x 2-channel
Sensor input
Monitored start
Cascading input
Monitored start
ON
1
2
3
Sensor input
Autostart
Cascading input
Autostart
NSC0_00933a
OFF
Siemens IC 10 AO 2014
11/5
Siemens AG 2014
Basic units
3TK2820
3TK2821
3TK2822
3TK2823
3TK2824
3TK2825
Sensors
Inputs
Electronic
--
--
--
--
--
--
1)
2)
--
--
--
--
--
--
--
--
--
--
--
Auto
--
Monitored
--
Cascading input
24 V DC
--
--
--
--
--
--
Key-operated switch
--
--
--
--
--
--
Stop category 0
3 NO
3 NO
2 NO
2 NO
2 NO
3 NO
Stop category 1
--
--
--
--
--
--
Stop category 0
--
--
--
--
--
--
Stop category 1
--
--
--
--
--
-2 NC
With contacts
Magnetically operated
switch
(Reed contacts)
Safety mats
Start
Enabling circuit,
floating
Enabling circuit,
electronic
Signaling outputs
Floating
1 NC
1 NC
--
--
--
Electronic
--
--
--
--
--
--
Standards
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
BG, SUVA,
UL, CSA
BG, SUVA,
UL, CSA
BG, SUVA,
UL, CSA
BG, SUVA,
UL, CSA
BG, SUVA,
UL, CSA
Performance level PL
according to
EN ISO 13849-1
Probability of a
dangerous failure per
hour (PFHd)
Test certificates
11
--
--
--
--
24 V AC/DC
--
24 V AC
--
--
--
--
--
115 V AC
--
--
--
230 V AC
--
--
--
--
--
--
--
--
--
Available
-- Not available
1)
2)
3)
11/6
Siemens IC 10 AO 2014
Siemens AG 2014
Basic units
Two-hand
Expansion
control devices units2)
3TK2826
24 V DC
Wide voltage
range
24 V DC tv
Wide voltage
range tv
3TK2827
3TK2828
tv
tv
3TK2834
3TK2830
Sensors
Inputs
--
Solid-state
--
--
--
--
--
--
With contacts
--
Magnetically operated
switch
(Reed contacts)
--
--
--
--
Safety mats
--
--
--
--
Auto
--
--
--
Monitored
--
--
--
Cascading input
24 V DC
--
--
--
--
Key-operated switch
--
--
--
--
--
--
--
--
Stop category 0
4 NO
4 NO
2 NO
2 NO
2 NO
2 NO
2 NO
4 NO
Stop category 1
--
--
2 NO
2 NO
2 NO
2 NO
--
--
Stop category 0
--
--
--
--
--
--
--
--
Stop category 1
--
--
--
--
--
--
--
--
1 NC
1 NO + 1 NC
2 NC
1 NO + 2 NC
1 NC
1 NC
2 NC
--
--
--
--
--
--
--
Start
Enabling circuit,
floating
Enabling circuit,
solid-state
Signaling outputs
Solid-state
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
Standards
24 V DC
24 V AC/DC
Test certificates
SIL level max.
according to IEC 61508
Performance level PL
according to
EN ISO 13849-1
Probability of a
dangerous failure
per hour (PFHd)
IEC 60204-1,
IEC 60204-1,
EN ISO 12100, EN ISO 12100,
EN ISO 13849-1, EN ISO 13849-1,
IEC 61508,
IEC 61508
EN 574
33)
33)
--
As basic unit
e3)
e3)
--
As basic unit
--
--
--
--
--
--
--
--
--
--
24 V AC
--
--
--
--
--
115 V AC
--
--
--
--
230 V AC
--
--
--
--
--
--
--
--
--
--
Available
-- Not available
1)
2)
3)
Siemens IC 10 AO 2014
11/7
11
Floating
Siemens AG 2014
3TK2821-1CB30
Rated control supply
voltage Us
3TK2825-1BB40
Start
3TK2826-2BB40
OFF-delay tv
DT
Article No.
V
3TK2827-1BB41
DT
Screw terminals
Price
per PU
Spring-type
terminals
Article No.
Price
per PU
Basic units
With floating enabling circuits
3TK2820
24 AC/DC
115 AC
230 AC
Auto/monitored
Auto/monitored
Auto/monitored
----
}
C
}
3TK2820-1CB30
3TK2820-1AJ20
3TK2820-1AL20
}
C
C
3TK2820-2CB30
3TK2820-2AJ20
3TK2820-2AL20
Auto/monitored
--
3TK2821-1CB30
3TK2821-2CB30
Auto
--
3TK2822-1CB30
3TK2822-2CB30
Monitored
--
3TK2823-1CB30
3TK2823-2CB30
Auto/monitored
Auto/monitored
Auto/monitored
Auto/monitored
-----
}
}
A
A
3TK2824-1CB30
3TK2824-1BB40
3TK2824-1AJ20
3TK2824-1AL20
C
A
C
C
3TK2824-2CB30
3TK2824-2BB40
3TK2824-2AJ20
3TK2824-2AL20
Auto/monitored
Auto/monitored
Auto/monitored
Auto/monitored
-----
}
C
B
A
3TK2825-1BB40
3TK2825-1AB20
3TK2825-1AJ20
3TK2825-1AL20
}
C
C
C
3TK2825-2BB40
3TK2825-2AB20
3TK2825-2AJ20
3TK2825-2AL20
Auto/monitored
Auto/monitored
---
A
A
3TK2826-1BB40
3TK2826-1CW30
A
C
3TK2826-2BB40
3TK2826-2CW30
3TK2821
24 AC/DC
3TK2822
24 AC/DC
3TK2823
24 AC/DC
3TK2824
24 AC/DC
24 DC
115 AC
230 AC
3TK2825
24 DC
24 AC
115 AC
230 AC
3TK2826
24 DC
24 ... 240 AC/DC
11
3TK2826 tv
24 DC
24 ... 240 AC/DC
Auto/monitored
Auto/monitored
0.05 ... 3
0.05 ... 3
C
C
3TK2826-1BB41
3TK2826-1CW31
C
C
3TK2826-2BB41
3TK2826-2CW31
24 DC
24 ... 240 AC/DC
Auto/monitored
Auto/monitored
0.5 ... 30
0.5 ... 30
A
C
3TK2826-1BB42
3TK2826-1CW32
C
C
3TK2826-2BB42
3TK2826-2CW32
24 DC
24 ... 240 AC/DC
Auto/monitored
Auto/monitored
5 ... 300
5 ... 300
C
C
3TK2826-1BB44
3TK2826-1CW34
C
C
3TK2826-2BB44
3TK2826-2CW34
3TK2827 tv
24 DC
24 AC
115 AC
230 AC
Monitored
Monitored
Monitored
Monitored
0.05 ... 3
0.05 ... 3
0.05 ... 3
0.05 ... 3
A
C
C
C
3TK2827-1BB41
3TK2827-1AB21
3TK2827-1AJ21
3TK2827-1AL21
C
A
C
C
3TK2827-2BB41
3TK2827-2AB21
3TK2827-2AJ21
3TK2827-2AL21
24 DC
24 AC
115 AC
230 AC
Monitored
Monitored
Monitored
Monitored
0.5 ... 30
0.5 ... 30
0.5 ... 30
0.5 ... 30
A
C
C
C
3TK2827-1BB40
3TK2827-1AB20
3TK2827-1AJ20
3TK2827-1AL20
C
C
C
C
3TK2827-2BB40
3TK2827-2AB20
3TK2827-2AJ20
3TK2827-2AL20
3TK2828 tv
24 DC
24 AC
115 AC
230 AC
Auto
Auto
Auto
Auto
0.05 ... 3
0.05 ... 3
0.05 ... 3
0.05 ... 3
A
C
C
C
3TK2828-1BB41
3TK2828-1AB21
3TK2828-1AJ21
3TK2828-1AL21
A
A
C
C
3TK2828-2BB41
3TK2828-2AB21
3TK2828-2AJ21
3TK2828-2AL21
24 DC
24 AC
115 AC
230 AC
Auto
Auto
Auto
Auto
0.5 ... 30
0.5 ... 30
0.5 ... 30
0.5 ... 30
A
C
C
C
3TK2828-1BB40
3TK2828-1AB20
3TK2828-1AJ20
3TK2828-1AL20
C
C
C
C
3TK2828-2BB40
3TK2828-2AB20
3TK2828-2AJ20
3TK2828-2AL20
11/8
Siemens IC 10 AO 2014
Siemens AG 2014
3TK2830-1CB30
Rated control supply
voltage Us
Start
OFF-delay tv
DT
Article No.
V
DT
Screw terminals
Price
per PU
Spring-type
terminals
Article No.
Price
per PU
24 DC
24 AC
115 AC
230 AC
-----
-----
A
C
C
C
3TK2834-1BB40
3TK2834-1AB20
3TK2834-1AJ20
3TK2834-1AL20
C
C
C
C
3TK2834-2BB40
3TK2834-2AB20
3TK2834-2AJ20
3TK2834-2AL20
----
}
C
B
3TK2830-1CB30
3TK2830-1AJ20
3TK2830-1AL20
}
C
C
3TK2830-2CB30
3TK2830-2AJ20
3TK2830-2AL20
Expansion units
With floating enabling circuits
3TK2830
----
11
24 AC/DC
115 AC
230 AC
Siemens IC 10 AO 2014
11/9
Siemens AG 2014
Overview
Benefits
11
11/10
Siemens IC 10 AO 2014
Siemens AG 2014
Basic units
3TK2840
Multi-function units
3TK2841
3TK2842
3TK2845
"Automatic and
monitored
start"
tv
"Springtype
interlocking"
"Solenoid
interlocking"
tv
tv
tv
tv
tv
Sensors
Inputs
Electronic
--
With contacts
Magnetically
operated switch
(Reed contacts)
Safety mats
--
--
--
--
--
Auto
--
--
--
--
Monitored
Cascading input
24 V DC
--
Key-operated switch
--
--
--
Stop category 0
--
--
--
2 NO
1 NO
2 NO
1 NO
2 NO
1 NO
1 NO
1 NO
Stop category 1
--
--
--
--
1 NO
--
1 NO
--
1 NO
1 NO
1 NO
Start
Enabling circuit,
floating
Enabling circuit,
electronic
Stop category 0
21)
Stop category 1
--
--
--
--
--
Signaling outputs
Floating
--
--
--
--
--
--
--
--
--
--
--
Electronic
--
--
--
Standards
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508,
EN 50156-1
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
Performance level PL
according to
EN ISO 13849-1
6.9 x 10-9
1/h
6.9 x 10-9
1/h
6.9 x 10-9
1/h
Probability of a
dangerous failure
per hour (PFHd)
Rated control
supply voltage
24 V DC
1.1 x 10-8
1/h
Available
-- Not available
1)
The outputs are only safe when used in combination with an external
contactor.
Siemens IC 10 AO 2014
11/11
11
Test certificates
Siemens AG 2014
3TK2841-1BB40
Rated control supply
voltage Us
3TK2842-1BB41
Start
3TK2845-1HB40
OFF-delay tv
3TK2845-1HB41
DT
Article No.
V
3TK2845-2DB40
DT
Screw terminals
Price
per PU
Spring-type
terminals
Article No.
Price
per PU
Basic units
With electronic enabling circuits
3TK2840
24 DC
Auto/monitored
--
3TK2840-1BB40
3TK2840-2BB40
Auto/monitored
--
3TK2841-1BB40
3TK2841-2BB40
0.05 ... 3
0.5 ... 30
5 ... 300
A
A
C
3TK2842-1BB41
3TK2842-1BB42
3TK2842-1BB44
B
A
C
3TK2842-2BB41
3TK2842-2BB42
3TK2842-2BB44
--
3TK2845-1HB40
3TK2845-2HB40
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2845-1HB41
3TK2845-1HB42
3TK2845-1HB44
C
C
C
3TK2845-2HB41
3TK2845-2HB42
3TK2845-2HB44
--
3TK2845-1DB40
3TK2845-2DB40
--/2
--/2
--/2
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2845-1DB41
3TK2845-1DB42
3TK2845-1DB44
C
C
C
3TK2845-2DB41
3TK2845-2DB42
3TK2845-2DB44
1/1
--
3TK2845-1EB40
3TK2845-2EB40
1/1
1/1
1/1
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2845-1EB41
3TK2845-1EB42
3TK2845-1EB44
C
C
C
3TK2845-2EB41
3TK2845-2EB42
3TK2845-2EB44
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2845-1FB41
3TK2845-1FB42
3TK2845-1FB44
C
C
C
3TK2845-2FB41
3TK2845-2FB42
3TK2845-2FB44
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2845-1GB41
3TK2845-1GB42
3TK2845-1GB44
C
C
C
3TK2845-2GB41
3TK2845-2GB42
3TK2845-2GB44
3TK2841
24 DC
Auto/monitored
Auto/monitored
Auto/monitored
Multi-function units
3TK2845 "Automatic and monitored start"
24 DC
1/1
1/1
1/1
1/1
--/2
11
--/2
--/2
--/2
11/12
--/2
--/2
--/2
Siemens IC 10 AO 2014
Siemens AG 2014
Overview
Benefits
11
Siemens IC 10 AO 2014
11/13
Siemens AG 2014
Basic units
3TK2850
3TK2851
3TK2852
3TK2853
Expansion units1)
Expansion units1)
3TK2856
3TK28 57 tv
Sensors
Inputs
--
--
Electronic
With contacts
--
--
--
--
--
--
--
Magnetically operated
switch
(Reed contacts)
--
--
Safety mats
--
--
--
--
--
--
Cascading input
24 V DC
--
--
--
Key-operated switch
--
--
--
--
--
--
Stop category 0
3 NO
2 NO
6 NO
3 NO
6 NO
--
Stop category 1
--
--
--
--
--
3 NO
Stop category 0
--
--
--
Stop category 1
--
--
--
--
--
--
Floating
--
1 NC
1 NC
--
1 NC
--
Electronic
--
--
--
--
--
--
Standards
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
--
As basic
unit
As basic
unit
Performance level PL
according to
EN ISO 13849-1
As basic
unit
As basic
unit
Probability of a
dangerous failure per
hour (PFHd)
24 V DC
24 V AC/DC
--
--
--
--
--
--
24 V AC
--
--
--
--
115 V AC
--
--
--
--
230 V AC
--
--
--
--
--
--
--
--
--
24 V DC
230 V AC
600 V AC
Start
Auto
Monitored
Enabling circuit,
electronic
Signaling outputs
Test certificates
11
Rated operational
voltage
Switching capacity
AC-15 at U = 230 V
6A
6A
6A
6A
6A
6A
DC-13 at U = 24 V
10 A
10 A
10 A
10 A
10 A
10 A
Available
-- Not available
1)
11/14
Siemens IC 10 AO 2014
Siemens AG 2014
3TK2850-2BB40
Rated control supply
voltage Us
3TK2851-2BB40
Start
3TK2852-2BB40
OFF-delay
tv
DT
Article No.
V
DT
Screw terminals
Price
per PU
Spring-type
terminals
Article No.
Price
per PU
Basic units
With contactor relay enabling circuits
3TK2850
24 DC
115 AC
230 AC
Auto/monitored
Auto/monitored
Auto/monitored
----
C
C
C
3TK2850-1BB40
3TK2850-1AJ20
3TK2850-1AL20
C
C
C
3TK2850-2BB40
3TK2850-2AJ20
3TK2850-2AL20
Auto/monitored
Auto/monitored
Auto/monitored
----
C
C
C
3TK2851-1BB40
3TK2851-1AJ20
3TK2851-1AL20
C
C
C
3TK2851-2BB40
3TK2851-2AJ20
3TK2851-2AL20
Auto/monitored
Auto/monitored
---
C
C
3TK2852-1BB40
3TK2852-1AL20
C
C
3TK2852-2BB40
3TK2852-2AL20
Auto/monitored
--
3TK2853-1BB40
3TK2853-2BB40
--
--
3TK2856-1BB40
3TK2856-2BB40
----
0.05 ... 3
0.5 ... 30
5 ... 300
C
C
C
3TK2857-1BB41
3TK2857-1BB42
3TK2857-1BB44
C
C
C
3TK2857-2BB41
3TK2857-2BB42
3TK2857-2BB44
3TK2851
24 DC
115 AC
230 AC
3TK2852
24 DC
230 AC
3TK2853
24 DC
Expansion units
With contactor relay enabling circuits
3TK2856
24 DC
3TK2857 tv
11
24 DC
24 DC
24 DC
Siemens IC 10 AO 2014
11/15
Siemens AG 2014
Overview
Benefits
3TK2810-0 standstill monitors
No additional sensors required
Signaling of faults with diagnostics display
Standstill time can be set
Unit can be used with frequency converters
3TK2810-1 speed monitors
Menu-prompted, easy parameterization
Direct diagnosis on the display means shorter downtimes
thanks to early fault detection
Integrated protective door monitoring means greater safety
because access to the plant is allowed only in the safe state
Suitable for all standard sensors, i.e. high flexibility
11
In addition to standstill and speed monitoring, the unit also features integrated monitoring of a protective door with spring-type
interlocking. Therefore, an additional evaluation unit is not
needed.
11/16
Siemens IC 10 AO 2014
Siemens AG 2014
Standstill
monitors
Speed monitors
3TK2810-0
3TK2810-1
Type
Sensors
Standstill
monitors
Speed monitors
3TK2810-0
3TK2810-1
Signaling outputs
Inputs
Floating
Electronic
--
Electronic
1 CO
2
With contacts
--
Standards
Without sensors
(measuring inputs)
--
--
--
IEC 60204-1,
EN ISO 12100,
EN ISO 13849-1,
IEC 61508
IEC 60947-5-1,
EN ISO 13849-1,
IEC 60204-1,
IEC 61508
Safety mats
--
--
Performance level PL
according to EN ISO 13849-1
24 V DC
230 V AC
--
Test certificates
Start
--
Cascading input
24 V DC
--
--
Probability of a dangerous
failure per hour (PFHd)
Key-operated switch
--
--
Auto
Monitored
--
Stop category 0
3 NO + 1 NC
400 V AC
--
Stop category 1
--
--
--
Stop category 0
--
--
Stop category 1
--
--
Available
-- Not available
3TK2810-0BA01
3TK2810-0GA02
OFF-delay
tv
11
PU (UNIT, SET, M) = 1
PS*
= 1 unit
PG
= 41L
3TK28 10-1BA41
DT
DT
Screw terminals
Article No.
Price
per PU
Spring-type terminals
Article No.
Price
per PU
Standstill monitors
3TK2810-0
24 DC
230 AC
400 AC
0.2 ... 6
0.2 ... 6
0.2 ... 6
B
C
C
3TK2810-0BA01
3TK2810-0GA01
3TK2810-0JA01
C
C
C
3TK2810-0BA02
3TK2810-0GA02
3TK2810-0JA02
A
B
3TK2810-1BA41
3TK2810-1KA41
A
B
3TK2810-1BA42
3TK2810-1KA42
B
B
3TK2810-1BA41-0AA0
3TK2810-1KA41-0AA0
B
B
3TK2810-1BA42-0AA0
3TK2810-1KA42-0AA0
Speed monitors
3TK2810-1 for NPN/PNP proximity switches and encoders
24 DC
120 ... 240 AC/DC
0 ... 600
0 ... 600
0 ... 600
0 ... 600
Siemens IC 10 AO 2014
11/17
Siemens AG 2014
Accessories
Use
Version
DT
Article No.
Price
PU
per PU (UNIT,
SET,
M)
PS*
PG
For 3TK28
3RT1900-1SB20
100
340 units
41B
3RT1900-1SB60
41B
3RT1900-1SD60
41B
For 3TK28
Push-in lugs
For screw fixing,
2 units are required for each device
3RP1903
10 units
41H
For 3TK2821 to
3TK2825, 3TK2827,
3TK2828, 3TK283.
Sealable covers
For securing against unauthorized
adjustment of setting knobs
3RP1902
5 units
41H
3TK2826-0DA00-0HA0
5 units
41L
3TK2820-0AA00
1 unit
41L
15-pole
3TK2810-1A
1 unit
41L
25-pole
3TK2810-1B
1 unit
41L
Connection cables
C
For connecting the speed monitor to the
3TK2810-1A or 3TK2810-1B adapter
3TK2810-0A
1 unit
41L
1 unit
41B
Blank labels
For 3TK28
3RT1900-1SB20
Adhesive labels
For SIRIUS devices
3RP1903
3RP1902
For 3TK2826
For 3TK2820
Sealing foil
For securing against unauthorized
adjustment of setting knobs
Adapters
For connecting encoders of type
Siemens/Heidenhain
3TK2810-1A
3TK2810-1B
11
For 3TK2810-1
3TK2810-0A
Screwdrivers
For all SIRIUS devices with spring-type
terminals 3.0 mm x 0.5 mm, length
approx. 200 mm, titanium gray/black, A
partially insulated
Spring-type terminals
3RA2908-1A
3RA2908-1A
1)
11/18
Siemens IC 10 AO 2014
16
Siemens AG 2014
Appendix
16/2
Ordering notes
16/3
16/10
Siemens contacts
16/11
16/12
Online services
Information and ordering in the internet
and on DVD
Information and download center,
Social media, Mobile media
16/18
Software licenses
16/20
Subject index
16/22
16/32
16
16/14
Industry Services
Your machines and plant can do more
with Industry Services
Industry Services for the entire life cycle
16/13
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Ordering notes
} Preferred type
A 1 or 2 working days
B 3 to 5 working days
C 6 to 15 working days
D 16 to 30 working days
X
On request
DT Article No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
3RA1110-0FA15-1AP0
3RV1901-0H
3RV1901-0H
1 10 units 41E
DT:
preferred type
PG: 41E
Order quantity 10 units or a multiple thereof
3SB3901-0AB
1 unit 41D
100 20 units
41J
3SB3901-0AB
DT:
preferred type
PG: 41J
Order quantity 20 units or a multiple thereof
Dimensions
All dimensions in mm.
16
For ordering products that differ from the versions listed in the catalog, the article number specified in the catalog must be supplemented with "Z"; the required features must be specified by
means of the alphanumeric order codes or in plain text.
16/2
Siemens IC 10 AO 2014
Small orders
When small orders are placed, the costs associated with order
processing are greater than the order value. We recommend
therefore that you combine several small orders. Where this is
not possible, we unfortunately have to charge a processing supplement of 20.-- to cover our costs for order processing and invoicing for all orders with a net goods value of less than 250.--.
Siemens AG 2014
Appendix
Standards and approvals
Safety characteristics
In the following standards, the so-called B10 values for calculating the safety integrity or safety integrity level (SIL) in functional
safety at a high or continuous demand rate are required also for
electromechanical switchgear:
IEC 62061 "Safety of machines - Functional safety of safetyrelated electrical, electronic and programmable electronic
control systems",
ISO 13849-1 "Safety of machines - Safety-related components
of controls - Part 1: General principles".
Failure rates of electromechanical components are required for
calculating the safety integrity or safety integrity level (SIL) in
functional safety:
- in the manufacturing industry at a high demand rate
- in the process industry at a low demand rate
Further requirements are laid down in IEC 61511-1 "Functional
safety - Safety instrumented systems for the process industry
sector - Part 1: Framework, definitions, system, hardware and
software requirements".
The German versions of the above standards are:
EN 62061 (VDE 0113-50), October 2005, which since
31.12.2005 has been harmonized as EN 62061 under the
Machinery Directive,
EN ISO 13849-1:2008,
EN 61511-1 (VDE 810-1).
The TV-tested Safety Evaluation Tool assists in calculating the
safety function as verification for the machine documentation.
It is available on the Internet at
www.siemens.com/safety-evaluation-tool.
16
Siemens IC 10 AO 2014
16/3
Siemens AG 2014
Appendix
Standards and approvals
The B10 value for devices subject to wear is expressed in
number of operating cycles:
it is the number of operating cycles after which 10 % of the test
specimens fail in the course of an endurance test (or: the number of operating cycles after which 10 % of the devices have
failed).
For low demand rates (mainly in the process industry), the failure
rate and not the B10 value is used to determine the failure probability.
With the help of the B10 value and a simplified formula (see
section 6.7.8.2.1 of EN 62061), the user can then calculate the
total failure rate of an electromechanical component:
= 0.1 x C/B10
with C = operating cycles per hour. C is specified by the user.
The failure rate is made up of safe (S) and dangerous (D)
failures:
= S+ D
or
D = [share of dangerous failures in %] x
S = [share of safe failures in %] x
The failure rate of the dangerous failures D of the components
used is needed for further calculations.
Listed in the following table are the standard B10 values and the
share of dangerous failures for SIRIUS product groups at a high
demand rate.
Standard B10 values (at a high demand rate)
(electromechanical components)
B10d =
B10
Share of dangerous failures
Calculation example
A protective door is monitored by a position switch with a
separate actuator.
The protective door is opened 4 times an hour.
The overall failure rate of the position switch is:
Standard
B10 value1)
(operating
cycles)
Share of
dangerous
failures
Standard
failure rates
(in FIT)1)
Share of
dangerous
failures2)
100
20 %
100
20 %
20 %
100
20 %
1 000 000
20 %
100
20 %
Hinge switches
(with positive-opening contacts)
1 000 000
20 %
100
20 %
Pushbuttons (non-latching,
with positive-opening contacts)
10 000 000
20 %
Hinge switches
(with positive-opening contacts)
100
20 %
Pushbuttons (non-latching)
(with positive-opening contacts)
100
20 %
Contactors/motor starters
(with positive-opening contacts or
mirror contacts)
100
< 40 %
- pulled to unlatch
- rotated to unlatch (also with lock)
30 000
100 000
20 %
20 %
(electromechanical components)
100 000
50 %
10 000 000
20 %
1 000 000
1 000
0002)
73 %
- 3TC
1 000 0002)
73 %
1 000 000
73 %
2)
16
1)
16/4
Siemens IC 10 AO 2014
1)
The failure rates specified in the table were limited to 100 FIT.
2)
Siemens AG 2014
Appendix
Standards and approvals
Standards
IEC
EN
DIN VDE
Title
60947-1
60947-2
60947-3
60947-1
60947-2
60947-3
----
60947-4-1
60947-4-2
60947-4-3
60947-4-1
60947-4-2
60947-4-3
----
60947-5-1
60947-5-2
60947-5-3
60947-5-1
60947-5-2
60947-5-3
----
60947-5-5
60947-5-5
--
60947-5-6
60947-5-6
--
60947-5-7
60947-5-8
60947-5-9
60947-5-7
60947-5-8
60947-5-9
----
Control circuit devices and switching elements - Electromechanical control circuit devices
Control circuitdevices and switching elements - Proximity switches
Control circuit devices and switching elements - Requirements for proximity devices with defined
behaviour under fault conditions (PDDB)
Control circuit devices and switching elements - Electrical emergency stop device with mechanical latching function
Control circuit devices and switching elements - DC interface for proximity sensors and switching
amplifiers (NAMUR)
Control circuit devices and switching elements - Requirements for proximity devices with analogue output
Control circuit devices and switching elements - Three-position enabling switches
Control circuit devices and switching elements - Flow rate switches
60947-6-1
60947-6-2
60947-6-1
60947-6-2
---
60947-7-1
60947-7-2
60947-7-3
60947-7-1
60947-7-2
60947-7-3
----
60947-8
60947-8
--
Control units for built-in thermal protection (PTC) for rotating electrical machines
62026-2
50295
--
Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs): Actuator sensor interface
(AS-i)
60269-1
60269-4
60269-1
60269-4
0636-1
--
60050-441
--
--
61439-1
61439-2
--
61439-1
61439-2
50274
----
61140
61140
--
Protection against electric shock - Common aspects for installation and equipment
60664-1
60664-1
--
Insulation coordination for electrical equipment in low-voltage systems: Principles, requirements and tests
60204-1
--
60204-1
50178
---
60079-14
60079-14
--
60079-2
60079-2
--
61810-1
61812-1
60999-1
61810-1
61812-1
60999-1
----
61558-1
61558-1
0570-11)
61558-2-1
61558-2-1
0570-2-11)
61558-2-2
61558-2-2
0570-2-21)
61558-2-4
61558-2-4
0570-2-41)
61558-2-6
61558-2-6
0570-2-61)
61558-2-9
61558-2-9
0570-2-91)
61558-2-12
61558-2-12
0570-2-121)
61558-2-13
61558-2-13
0570-2-131)
61558-2-15
61558-2-20
61558-2-15
61558-2-20
0570-2-151)
0570-2-201)
Particular requirements and tests for separating transformers and power supplies incorporating
separating transformers for general applications
Particular requirements and tests for control transformers and power supplies incorporating control transformers
Particular requirements and tests for isolating transformers and power supply units incorporating isolating
transformers
Particular requirements and tests for safety isolating transformers and power supply units incorporating
safety isolating transformers
Particular requirements and tests for transformers and power supply units for class III handlamps for
tungsten filament lamps
Particular requirements and tests for constant voltage transformers and power supply units for constant
voltage
Particular requirements and tests for auto transformers and power supply units incorporating auto transformers
Particular requirements and tests for isolating transformers for the supply of medical locations
Particular requirements and tests for small reactors
62041
62041
0570-101)
Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements
60076-11
60076-11
--
61000-4-1
61000-4-1
--
Electromagnetic compatibility (EMC): Testing and measuring techniques - Overview of IEC 61000-4 series
61000-6-2
61000-6-3
61000-6-2
61000-6-3
0839-6-2
--
61000-6-4
61000-6-4
--
60044-1
60044-1
--
VDE classification.
16
1)
Low-voltage switchgear and controlgear assemblies - Protection against electric shock - Protection
against unintentional direct contact with hazardous live parts
Siemens IC 10 AO 2014
16/5
Siemens AG 2014
Appendix
Standards and approvals
UL
CSA C22.2
ASME
JIS
Title
506
508
60947-1
60947-4-1A
-----
-----
-----
489
1012
---
---
---
Specialty transformers
Industrial control equipment
Low-voltage switchgear and controlgear - Part 1: General rules
Low-voltage switchgear and controlgear - Part 4-1: Contactor and motor starters Electromechanical contactors and motor starters
Molded case circuit breakers, molded case switches, and circuit breaker enclosures
Power units other than CLASS 2
1561
5085
60601-1
----
----
----
1604
--
--
--
1059
-486A-486B --
---
---
486E
--
--
--
Equipment wiring terminals for use with aluminum and/or copper conductors
50
50E
---
---
---
---
No. 66
No. 14
No. 60947-1
No. 60947-4-1A
-----
-----
---
No. 5
No. 107-1
---
---
Specialty transformers
Industrial control equipment
Low-voltage switchgear and controlgear - Part 1: General rules
Low-voltage switchgear and controlgear - Part 4-1: Contactor and motor starters
Electromechanical contactors and motor starters
Molded case circuit breakers, molded case switches and circuit breaker enclosures
General use power supplies
--
--
A17.5 / B 44.1 --
--
--
--
In some cases, CSA for Canada and UL for the USA only approve special switchgear versions. Such special versions are
listed separately from the standard versions in the individual
parts of this catalog.
For this equipment, partial limitations of the maximum permissible voltages, currents and ratings can be imposed, or special
approval and, in some cases, special identification is required.
For use on board ship, the specifications of the marine classification societies must be observed (see table below). In some
cases, they require type tests of the components to be
approved.
Canada 1)
USA 1)
China
CSA UL
(USA)
UL
CQC
Mark of conformity
c u cU
c UUS
c UUS
c uUS
c uUS
Approval requirement
Remarks
UL and CSA are authorized to grant approval certificates in accordance with Canadian and North American regulations. Please note:
These approvals are not recognized in many cases and must be covered by additional approvals issued by the national testing agency.
1)
+
CCC
For registration numbers and file numbers for approvals, please visit
www.siemens.com/automation/support and select "Product Support".
Germany
United
Kingdom
France
Norway
CIS
Italy
Poland
USA
Name
Germanischer
Lloyd
Lloyds
Register of
Shipping
Bureau
Veritas
Det Norske
Veritas
Russian
Maritime
Register of
Shipping
Registro
Italiano
Navale
Polski
Rejestre
Statkw
American
Bureau of
Shipping
Codes
GL1)
LRS
BV
DNV1)
RMRS
RINA
PRS
ABS
16
1)
DNV and GL have merged and call themselves the DNV/GL Group
16/6
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Standards and approvals
CE marking
Manufacturers of products which fall within the subject area to
which EC directives apply must identify their products, operating
instructions or packaging with a CE mark of conformity.
By attaching the CE mark, the manufacturer confirms that the
product conforms to the relevant basic requirements of all directives applicable to the product. The mark of conformity is a mandatory requirement for putting products into circulation
throughout the EC.
ALPHA/LOVAG
Siemens AG sits in the ALPHA committee of "ALPHA im VDE".
The responsibility of manufacturers and the high quality of products are promoted by "ALPHA im VDE" by means of supportive
procedural guidelines for testing equipment according to the
currently valid standards.
SGS BELGIUM NV
Division SGS CEBEC
ALPHA in VDE
ASEFA
ACAE
IMQ S.p.A
Intertek Semko AB
APPLUSS + CTC
Belgium
Germany
France
Italy
Sweden
Spain
Accident prevention
16
Test certificates and approvals from IFA (institute for occupational safety and health of the German social accident insurance), SUVA (Swiss institute for accident prevention), BG ETEM
(German trade association for energy, textiles, electrical goods
and media products) and VDE are available for some devices in
safety control systems. For details, see the respective product
descriptions.
Siemens IC 10 AO 2014
16/7
Siemens AG 2014
Appendix
Standards and approvals
Selection box
Identifying markings
For the 3RV, 3RU, 3RB, 3UF, 3RN and 3RW motor protection
devices, the corresponding declarations of conformity and
prototype test certificates for Category M2, 2G, and in some
cases 2D, are available and can be supplied on request.
All equipment must be marked in according to the ATEX guideline. The ATEX identification code contains the equipment group,
the approved environment, the number of the certification authority and other technical data that was determined from the
type test.
1)
16
16/8
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Standards and approvals
Listed Product
Devices are identified using the "UL listing mark" on the rating plate
e.g. USA: u LISTED XXX
Canada: cu LISTED XXX
IND. CONT. EQ.
IND. CONT. EQ.
(XXX stands for: UL Code Classification Number)
GOST mark
The C-Tick license is required for marketing Siemens components in Australia. Electronic devices must provide proof of EMC
clearance in Australia, similar to the CE mark of conformity laid
down by the EMC directive applicable in the EC and bear the
"C-Tick" mark. These requirements have been in force since
October 1st, 1999.
A new C-Tick mark has been in existence since 01.03.2013. The
transition period in which the old C-Tick mark will remain valid is
three years.
CCC approval
16
Siemens IC 10 AO 2014
16/9
Siemens AG 2014
Appendix
Siemens contacts
16
16/10
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Online Services
Information and Ordering
in the Internet and on DVD
16
www.siemens.com/industrymall
Siemens IC 10 AO 2014
16/11
Siemens AG 2014
Appendix
Online Services
Information and Download Center
Social Media, Mobile Media
Downloading Catalogs
In addition to numerous other useful documents, you can also
find the catalogs listed on the back inside cover of this catalog
in the Information and Download Center. Without having to register, you can download these catalogs in PDF format or increasingly as digital page-turning e-books.
The filter dialog box above the first catalog displayed makes it
possible to carry out targeted searches. If you enter MD 3 for
example, you will find both the MD 30.1 and MD 31.1 catalogs.
If you enter ST 70 both the ST 70 catalog and the associated
news or add-ons are displayed.
Visit us on the web at:
www.siemens.com/industry/infocenter
Social Media
Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other
Siemens employees, and much, much more. Stay in the know
and follow us on the ever-expanding global network of social
media.
Connect with Siemens Industry at our central access point:
www.siemens.com/industry/socialmedia
Or via our product pages at:
www.siemens.com/automation
or
www.siemens.com/drives
To find out more about Siemens' current social media activities
visit us at:
www.siemens.com/socialmedia
Mobile Media
Discover the world of Siemens.
We are also constantly expanding our offering of cross-platform
apps for smartphones and tablets. You will find the current Siemens apps at the app store (iOS) or at Google Play (Android).
16
The Siemens app, for example, tells you all about the history, latest developments and future plans of the company with informative pictures, fascinating reports and the most recent press
releases.
16/12
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Industry Services
Your machines and plant can do more
with Industry Services.
Whether it is production or process industry - in view of rising
cost pressure, growing energy costs, and increasingly stringent
environmental regulations, services for industry are a crucial
competitive factor in manufacturing as well as in process industries.
All over the world Siemens supports its customers with product,
system, and application-related services throughout the entire
life cycle of a plant. Right from the earliest stages of planning,
engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the
Siemens experts unique technological and product knowledge
and industry expertise.
Thus downtimes are reduced and the utilization of resources is
optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs.
Discover all advantages of our service portfolio:
www.siemens.com/industry-services
{GjGMGG
lGz
lGMG G
lGz
{GjGMGG
lGz
lGMG
lGz
tGM G
vGz
Modernization
Modernization
Planning
Planning
Online Support
Technical Support
Spare Parts
Repair Services
Field Services
Training
Operation
Operation
{GjGMGG
lGz
Engineer
Engineer
&
& Build
Build
lGMG
lGz
wGtGMGG
jGt
zG
lGMGlG
tGMGvGz
G_DA65_EN_00270
16
Siemens supports its clients with technology based Services across a plants entire life cycle.
Siemens IC 10 AO 2014
16/13
Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Online Support
Online support is a comprehensive information system for all
questions relating to products, systems, and solutions that
Siemens has developed for industry over time. With more than
300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to
detailed product information as well as numerous solution examples for programming, configuration and application.
The content, in six languages, is increasingly multimediabased
and now also available as a mobile app. Online supports
Technical Forum offers users the opportunity to share information with each other. The Support Request option can be used
to contact Siemens technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date.
www.siemens.com/industry/onlinesupport
Online Support App
Using the Online Support app, you can access over 300,000
documents covering all Siemens industrial products - anywhere,
any time. Regardless of whether you need help implementing
your project, fault-finding, expanding your system or are planning a new machine.
The app is available free of charge from the Apple App Store
(iOS) or from Google Play (Android).
www.siemens.com/industry/onlinesupportapp
Technical Support
16
16/14
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Spare Parts
Drive and automation systems must be available at all times.
Even a single missing spare part can bring the entire plant to a
standstill and result in substantial financial losses for the operator. The spare parts services from Siemens protects against
such losses with the aid of quickly available, original spare
parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions,
individual spare parts packages ensure a preventive stock of
spare parts on-site. The spare parts services is available around
the world and around the clock. Optimum supply chain logistics
ensure that replacement components reach their destination as
quickly as possible. Siemens logistics experts take care of planning and management as well as procurement, transportation,
customs handling, warehousing, and complete order management for spare parts.
Repair Services
Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair
and maintenance. Siemens offers complete customer and repair
services on site and in repair centers as well as technical
emergency services worldwide. The repair services include all
measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics,
spare parts storage and rapid manufacturing are available to
plant operators in all verticals. With a global network of certified
repair shops operated by Siemens as well as third parties, Siemens handles the maintenance and overhaul of motors, converters, and other devices as an authorized service partner.
Field Services
16
Siemens IC 10 AO 2014
16/15
Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Training
Increasingly, up-to-date knowledge is becoming a determining
factor in success. One of the key resources of any company is
well-trained staff that can make the right decision at the right moment and take full advantage of the potential. With SITRAIN
Training for Industry, Siemens offers comprehensive advanced
training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer.
SITRAIN covers Siemens entire product and system portfolio in
the field of automation and drives. Together with the customer,
Siemens determines the companys individual training needs
and then develops an advanced training program tailored to the
desired requirements. Additional services guarantee that the
knowledge of all Siemens partners and their employees is always up-to-date.
16
Efficient energy use and resource conservation these top sustainability concerns pay off both for the environment and for
companies. Siemens offers integrated solutions that unlock all
technical and organizational potential for successful environmental management. Customized consulting services are aimed
at sustainably lowering the cost of energy and environmental
protection and thus increasing plant efficiency and availability.
The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and optimized water consumption throughout the entire company.
Improved data transparency makes it possible to identify savings potential, reduce emissions, optimize production processes, and thereby noticeably cut costs.
16/16
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Modernization & Optimization Services
High machine availability, expanded functionality and selective
energy savings in all industries, these are decisive factors for
increasing productivity and lowering costs. Whether a company
wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens experts support the
projects from planning to commissioning.
Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments
over the long term and increases economic efficiency in operation.
Service Contracts
16
Siemens IC 10 AO 2014
16/17
Siemens AG 2014
Appendix
Software licenses
Overview
Software types
Software requiring a license is categorized into types.
The following software types have been defined:
Engineering software
Runtime software
Engineering software
This includes all software products for creating (engineering)
user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing.
Data generated with engineering software and executable
programs can be duplicated for your own use or for use by thirdparties free-of-charge.
Runtime software
This includes all software products required for plant/machine
operation, e.g. operating system, basic system, system expansions, drivers, etc.
The duplication of the runtime software and executable programs created with the runtime software for your own use or for
use by third-parties is subject to a charge.
You can find information about license fees according to use in
the ordering data (e.g. in the catalog). Examples of categories of
use include per CPU, per installation, per channel, per instance,
per axis, per control loop, per variable, etc.
Information about extended rights of use for parameterization/configuration tools supplied as integral components of the
scope of delivery can be found in the readme file supplied with
the relevant product(s).
License types
Siemens Industry Automation & Drive Technologies offers various types of software license:
Floating license
Single license
Rental license
Rental floating license
Trial license
Demo license
Demo floating license
Floating license
The software may be installed for internal use on any number of
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use
begins when the software is started.
A license is required for each concurrent user.
Single license
Unlike the floating license, a single license permits only one
installation of the software per license.
The type of use licensed is specified in the ordering data and
in the Certificate of License (CoL). Types of use include for
example per instance, per axis, per channel, etc.
One single license is required for each type of use defined.
16
Rental license
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific period of time (the operating hours do
not have to be consecutive).
One license is required for each installation of the software.
16/18
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Software licenses
Overview
License key
Siemens Industry Automation & Drive Technologies supplies
software products with and without license keys.
The license key serves as an electronic license stamp and
is also the "switch" for activating the software (floating license,
rental license, etc.).
The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the
license key (which represents the license).
16
ServicePack
ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses.
Siemens IC 10 AO 2014
16/19
Siemens AG 2014
Appendix
Subject index
Numerics
45 mm standard mounting rail ......................7/35
A
Adapters
For safety relays .....................................11/18
Additional load modules for contactors
and contactor relays ............................. 3/44, 5/8
Arc chutes
For contactors ..........................................3/53
Assembly kits
For contactor assemblies ............... 3/64, 3/73
ATEX
Motor starter protectors ..............................7/6
Overload relays ..................... 7/40, 7/47, 7/54
Auxiliary releases
For motor starter protectors ........... 7/17, 7/19
Auxiliary switch blocks
For contactors and
contactor relays ...........................3/34 ... 3/39
- Laterally mountable ...............................3/38
- Solid-state compatible ..........................3/39
- Solid-state time-delay ............................3/40
Auxiliary switches
For motor starter protectors ............ 7/2, 7/14,
......................................................7/16 ... 7/18
Auxiliary terminals .............................. 3/45, 3/46
B
Base plates
For contactor assemblies ............... 3/63, 3/73
Box terminal blocks ............................ 7/53, 7/60
Busbar adapters
For load feeders .......................................8/24
For motor starter protectors ............ 7/2, 7/20,
......................................................... 7/22, 7/28
Busbar systems
For load feeders .......................................8/26
For motor starter protectors .... 7/2, 7/20, 7/22
16
C
Cable releases for RESET .................. 7/45, 7/52
Capacitor contactors ....................................4/10
Coil repeat terminals .....................................3/63
Connecting cables .......................................7/59
Connection cables
For safety relays .....................................11/18
Connection modules for contactors .............3/47
Connections
For motor starter protectors .....................7/26
Connectors, mechanical ...............................3/65
Contactor assemblies
Contactor assemblies for wye-delta starting
- Complete units .........................3/66 ... 3/72
- Components for customer assembly ....3/73
Reversing contactor assemblies
- Complete units .........................3/58 ... 3/62
- Components for customer
assembly ........................ 3/58, 3/63 ... 3/65
Contactor bases ...........................................7/34
Contactor relays ................................5/3 ... 5/14
Coupling contactors .................................5/11
Latched ....................................................5/10
With auxiliary switch block ................. 5/5, 5/6
16/20
Siemens IC 10 AO 2014
Contactors
Capacitor contactors ............................... 4/10
For railway applications ............. 4/13 ... 4/16,
......................................................... 5/13, 5/14
For switching motors ................... 3/5 ... 3/53,
..................................................... 4/13 ... 4/16
- Vacuum contactors ...................... 3/26, 3/27
- With auxiliary switch block ....... 3/14 ... 3/21
For switching resistive loads ........... 4/4 ... 4/7
With extended operating range .. 4/13 ... 4/16,
......................................................... 5/13, 5/14
Contactors and contactor relays
Arc chutes ................................................ 3/53
Auxiliary switch blocks ............... 3/34 ... 3/39
Auxiliary switch blocks,
solid-state time-delay .............................. 3/40
Auxiliary terminals ........................... 3/45, 3/46
Control kit (manual operation) ................... 5/9
Coupling links .......................................... 3/45
Covers .............................................. 3/46, 5/9
Insulation stop for
spring-type terminals ........................ 3/48, 5/9
LED module for indicating
contactor operation ................................. 3/45
Links for paralleling ................................. 3/48
Mechanical latching blocks ..................... 3/44
OFF-delay devices .................................... 5/9
Solenoid coils ............................. 3/49 ... 3/52
Timing relay blocks, solid-state ............... 3/41
Control kit (manual operation)
For contactors and contactor relays .......... 5/9
Coupling contactors
For switching auxiliary circuits ................. 5/11
For switching motors .................. 3/54 ... 3/57
Coupling links
For contactors and contactor relays ........ 3/45
Covers
For contactors .......................................... 3/46
For motor starter protectors ..................... 7/25
Covers, sealable
For contactors ................................... 3/46, 5/9
For motor starter protectors ..................... 7/25
For safety relays ..................................... 11/18
Current measuring modules ........................ 7/59
D
Delay blocks for contactors
Pneumatic ................................................ 3/41
Solid-state ................................................ 3/41
Direct-on-line starters, load feeders . 8/4 ... 8/11
Distance protection ............................... 7/2, 7/16
Door-coupling rotary operating mechanisms
For motor starter protectors .... 7/2, 7/23, 7/24
E
Electrical remote RESET .............................. 7/45
EMC suppression modules for contactors ... 3/44
EMERGENCY-STOP door-coupling
rotary operating mechanisms
For motor starter protectors ..................... 7/24
EMERGENCY-STOP mushroom button
For motor starter protectors ..................... 7/31
Encapsulated starters ............................. 9/3, 9/4
Enclosures
For motor starter protectors 7/2, 7/29 ... 7/31
Enclosures for flush mounting
For motor starter protectors .... 7/2, 7/29, 7/31
Enclosures for surface mounting
For motor starter protectors .... 7/2, 7/29, 7/31
End covers ................................................... 7/35
Evaluation modules ...................................... 7/56
Expansion plugs ........................................... 7/35
Explosion protection (ATEX)
Motor starter protectors .............................. 7/6
Overload relays ..................... 7/40, 7/47, 7/54
F
Feeder terminals
For contactors .......................................... 3/73
For motor starter protectors ..................... 7/21
Front plates
For motor starter protectors 7/2, 7/29 ... 7/31
Function expansion modules ....................... 7/58
Fuse monitoring .................................... 7/2, 7/14
Fuseless load feeders ....................... 8/3 ... 8/26
H
Hybrid link modules
For motor starter protectors ..................... 7/27
I
Indicator lights
For motor starter protectors ..................... 7/31
Infeed system
For load feeders ....................................... 8/26
For motor starter protectors 7/2, 7/32 ... 7/35
Inscription labels
For overload relays ................ 7/46, 7/53, 7/61
For safety relays ..................................... 11/18
Unlabeled ................................................. 3/48
Insulated three-phase busbar system
For motor starter protectors .... 7/2, 7/20, 7/22
Insulation stop for
spring-type terminals ............................ 3/48, 5/9
Interlocks
For contactor assemblies ......................... 3/63
Isolator modules .......................... 7/2, 7/17, 7/19
L
Latched contactor relays .............................. 5/10
Latching blocks, mechanical
For contactors .......................................... 3/44
LED module
For indicating contactor operation ........... 3/45
Link modules
For motor starter protectors .... 7/2, 7/27, 7/28
Links for paralleling
For contactors ................................ 3/48, 3/73
Siemens AG 2014
Appendix
Subject index
O
OFF-delay devices for contactors and
contactor relays .................................... 3/41, 5/9
Overload relays ............................... 7/36 ... 7/61
Explosion protection (ATEX) . 7/40, 7/47, 7/54
Solid-state ................................... 7/36 ... 7/39
- For High-Feature applications . 7/54 ... 7/59
- For standard applications ........ 7/49 ... 7/53
Thermal ....................................... 7/36 ... 7/39
- For standard applications ........ 7/40 ... 7/46
P
Plug-in connectors ....................................... 7/34
Pneumatic delay blocks for contactors ........ 3/41
Protection equipment ........................ 7/1 ... 7/61
Push-in lugs
For motor starter protectors ..................... 7/26
For overload relays .................................. 7/60
R
Remote motorized operating mechanisms
For motor starter protectors .... 7/2, 7/23, 7/24
Remote RESET, electrical ............................. 7/45
RESET for overload relays
Cable releases ................................ 7/45, 7/52
Electrical remote ...................................... 7/45
Mechanical ..................................... 7/45, 7/52
Reversing contactor assemblies ..... 3/58 ... 3/62
Reversing starters, load feeders ..... 8/12 ... 8/19
Rotary operating mechanisms
For motor starter protectors .... 7/2, 7/23, 7/24
S
Safety relays, 3TK28
With contactor relay
enabling circuits ..................... 11/13 ... 11/15
With electronic
enabling circuits ..................... 11/10 ... 11/12
With relay enabling circuits ......... 11/5 ... 11/9
With special functions ................. 11/16, 11/17
Scale covers
For motor starter protectors ..................... 7/25
Screw adapters for contactors ..................... 3/47
Screwdriver ....................... 3/48, 5/9, 7/28, 7/46,
................................................. 7/53, 7/61, 11/18
Sealable covers
For motor starter protectors ..................... 7/25
For overload relays .................................. 7/53
Shunt releases
For motor starter protectors .... 7/2, 7/17, 7/19
Signaling switches
For motor starter protectors .... 7/2, 7/17, 7/19
Solder pin adapters for contactors .............. 3/47
Solder pin connections
For motor starter protectors ............ 7/25, 7/26
Solenoid coils
For contactors ............................. 3/49 ... 3/52
Solid-state overload relays .............. 7/36 ... 7/39
For High-Feature applications .... 7/54 ... 7/59
For standard applications ........... 7/49 ... 7/53
Standard mounting rail adapters
For load feeders ...................................... 8/23
Starter combinations ............................. 7/2, 7/12
Surge suppressors for contactors and
contactor relays .................................... 3/42, 5/8
System protection ................................. 7/2, 7/15
T
Terminal blocks
For motor starter protectors ........... 7/26, 7/35
For overload relays ................................... 7/53
Terminal brackets ............................... 7/45, 7/52
Terminal covers
For contactors .......................................... 3/46
For motor starter protectors ..................... 7/25
For overload relays ................ 7/45, 7/53, 7/60
Terminals
For contactor assemblies ......................... 3/73
For motor starter protectors ..................... 7/21
Thermal overload relays ..................7/36 ... 7/39
For standard applications ...........7/40 ... 7/46
Three-phase
Busbar systems
- For load feeders .................................... 8/26
- For motor starter protectors ........ 7/20, 7/22
Busbars
- For motor starter protectors ........ 7/21, 7/34
Feeder terminals ...................................... 7/21
Timing relay blocks
For contactors and contactor relays ........ 3/41
Tools for
Spring-type terminals .................... 7/28, 7/46,
.............................................. 7/53, 7/61, 11/18
Transformer protection ......................... 7/2, 7/13
Type E
Terminal blocks ........................................ 7/26
Terminals .................................................. 7/21
U
Undervoltage releases
For motor starter protectors .... 7/2, 7/17, 7/19
Unit labeling plates
For overload relays ................ 7/46, 7/53, 7/61
For safety relays ..................................... 11/18
V
Vacuum contactors ............................. 3/26, 3/27
Voltage transformer circuit breakers .... 7/2, 7/16
W
Wiring modules
For contactor assemblies ......................... 3/65
Wye-delta starting
Contactor assemblies .................3/66 ... 3/73
16
M
Mechanical connectors
For contactor assemblies .........................3/65
Mechanical interlocks
For contactor assemblies .........................3/63
Mechanical latching blocks
For contactors ..........................................3/44
Mechanical RESET ............................. 7/45, 7/52
Modules for remote RESET, electrical ..........7/45
Molded case motor starter protectors ............7/3
Molded-plastic enclosures
For motor starter protectors ........7/29 ... 7/31
Motor protection ........................ 7/2, 7/8 ... 7/11
Motor starter protectors ............. 7/2, 7/8 ... 7/31
Auxiliary releases ........................... 7/17, 7/19
Auxiliary switches ....... 7/2, 7/14, 7/16 ... 7/18
Busbar adapters ............7/2, 7/20, 7/22, 7/28
Busbar systems ....................... 7/2, 7/20, 7/22
Distance protection .......................... 7/2, 7/16
Door-coupling rotary operating
mechanisms ............................ 7/2, 7/23, 7/24
EMERGENCY-STOP door-coupling
rotary operating mechanisms ..................7/24
Enclosures ........................... 7/2, 7/29 ... 7/31
Enclosures for flush mounting ...................7/2,
......................................................7/29 ... 7/31
Enclosures for surface mounting ..............7/2,
......................................................7/29 ... 7/31
Explosion protection (ATEX) .......................7/6
Front plates ......................... 7/2, 7/29 ... 7/31
Fuse monitoring ................................ 7/2, 7/14
Hybrid link modules .................................7/27
Indicator lights ..........................................7/31
Infeed system ...................... 7/2, 7/32 ... 7/35
Insulated three-phase busbar system ......7/2,
......................................................... 7/20, 7/22
Isolator modules ...................... 7/2, 7/17, 7/19
Link modules ........................... 7/2, 7/27, 7/28
Molded-plastic enclosures ..........7/29 ... 7/31
Motor protection .................... 7/2, 7/8 ... 7/11
- With overload relay function ..................7/11
Mounting accessories .................7/25 ... 7/28
Remote motorized operating
mechanisms ............................ 7/2, 7/23, 7/24
Rotary operating mechanisms 7/2, 7/23, 7/24
Scale covers .............................................7/25
Shunt releases ......................... 7/2, 7/17, 7/19
Signaling switches .................. 7/2, 7/17, 7/19
Solder pin connections .................. 7/25, 7/26
Starter combinations ........................ 7/2, 7/12
System protection ............................ 7/2, 7/15
Terminal blocks ........................................7/26
Terminals ..................................................7/21
Transformer protection ..................... 7/2, 7/13
Type E terminals .......................................7/21
Undervoltage releases ............ 7/2, 7/17, 7/19
Voltage transformer circuit breakers 7/2, 7/16
Motor starters
Encapsulated starters ........................ 9/3, 9/4
For use in the control cabinet ........8/1 ... 8/26
For use in the field ...........................9/1 ... 9/4
High degree of protection ...............9/1 ... 9/4
Mounting accessories
For motor starter protectors ........7/25 ... 7/28
Siemens IC 10 AO 2014
16/21
Siemens AG 2014
Appendix
Article number index
Overview
Article No.
Page
3RA11
Article No.
Page
3RA1120-1F.
8/8, 8/10
8/8, 8/10
3RA1120-1FA
8/4, 8/6
3RA1110-0BA
8/4, 8/6
3RA1120-1G.
8/8, 8/10
3RA1110-0C.
8/8, 8/10
3RA1120-1GA
8/4, 8/6
3RA1110-0CA
8/4, 8/6
3RA1120-1H.
8/8, 8/10
3RA1110-0D.
8/8, 8/10
3RA1120-1HA
8/4, 8/6
3RA1110-0DA
8/4, 8/6
3RA1120-1J.
8/8, 8/10
3RA1110-0E.
8/8, 8/10
3RA1120-1JA
8/4, 8/6
3RA1110-0EA
8/4, 8/6
3RA1120-1K.
8/8, 8/10
3RA1110-0F.
8/8, 8/10
3RA1120-1KA
8/4, 8/6
3RA1110-0FA
8/4, 8/6
3RA1120-4A.25
8/9, 8/11
3RA1110-0G.
8/8, 8/10
3RA1120-4A.26
8/8, 8/10
3RA1110-0GA
8/4, 8/6
3RA1120-4AA25
8/5, 8/7
3RA1110-0H.
8/8, 8/10
3RA1120-4AA26
8/4, 8/6
3RA1110-0HA
8/4, 8/6
3RA1120-4B.25
8/9, 8/11
3RA1110-0J.
8/8, 8/10
3RA1120-4B.26
8/8, 8/10
3RA1110-0JA
8/4, 8/6
3RA1120-4BA25
8/5, 8/7
3RA1110-0K.
8/8, 8/10
3RA1120-4BA26
8/4, 8/6
3RA1110-0KA
8/4, 8/6
3RA1120-4C.
8/9, 8/11
3RA1110-1A.
8/8, 8/10
3RA1120-4CA
8/5, 8/7
3RA1110-1AA
8/4, 8/6
3RA1120-4D.
8/9, 8/11
3RA1110-1B.
8/8, 8/10
3RA1120-4DA
8/5, 8/7
3RA1110-1BA
8/4, 8/6
3RA113
8/4, 8/6
3RA1110-1C.
8/9, 8/11
3RA12
3RA1110-1CA
8/5, 8/7
3RA1210-0B.
8/16, 8/18
3RA1110-1D.
8/9, 8/11
3RA1210-0BA
8/12, 8/14
3RA1110-1DA
8/5, 8/7
3RA1210-0C.
8/16, 8/18
3RA1110-1E.
8/9, 8/11
3RA1210-0CA
8/12, 8/14
3RA1110-1EA
8/5, 8/7
3RA1210-0D.
8/16, 8/18
3RA1110-1F.
8/9, 8/11
3RA1210-0DA
8/12, 8/14
3RA1110-1FA
8/5, 8/7
3RA1210-0E.
8/16, 8/18
3RA1110-1G.
8/9, 8/11
3RA1210-0EA
8/12, 8/14
3RA1110-1GA
8/5, 8/7
3RA1210-0F.
8/16, 8/18
3RA1110-1H.
8/9, 8/11
3RA1210-0FA
8/12, 8/14
3RA1110-1HA
8/5, 8/7
3RA1210-0G.
8/16, 8/18
3RA1110-1J.
8/9, 8/11
3RA1210-0GA
8/12, 8/14
3RA1110-1JA
8/5, 8/7
3RA1210-0H.
8/16, 8/18
3RA1110-1K.
8/9, 8/11
3RA1210-0HA
8/12, 8/14
3RA1110-1KA
8/5, 8/7
3RA1210-0J.
8/16, 8/18
3RA1120-1C.
8/8, 8/10
3RA1210-0JA
8/12, 8/14
3RA1120-1CA
8/4, 8/6
3RA1210-0K.
8/16, 8/18
3RA1120-1D.
8/8, 8/10
3RA1210-0KA
8/12, 8/14
3RA1120-1DA
8/4, 8/6
3RA1210-1A.
8/16, 8/18
3RA1120-1E.
8/8, 8/10
3RA1210-1AA
8/12, 8/14
3RA1120-1EA
8/4, 8/6
3RA1210-1B.
8/16, 8/18
16
3RA1110-0B.
16/22
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Article number index
Article No.
Page
Article No.
3RA1210-1BA
8/12, 8/14
3RA13
Page
3RA1210-1C.
8/17, 8/19
3RA131
3/59
3RA1210-1CA
8/13, 8/15
3RA132
3/60
3RA1210-1D.
8/17, 8/19
3RA133
3/61
3RA1210-1DA
8/13, 8/15
3RA134
3/62
3RA1210-1E.
8/17, 8/19
3RA14
3RA1210-1EA
8/13, 8/15
3RA141
3/68
3RA1210-1F.
8/17, 8/19
3RA142
3/69
3RA1210-1FA
8/13, 8/15
3RA143
3/70 ... 71
3RA1210-1G.
8/17, 8/19
3RA144
3/72
3RA1210-1GA
8/13, 8/15
3RA19
3RA1210-1H.
8/17, 8/19
3RA190
8/23
3RA1210-1HA
8/13, 8/15
3RA1911-1
7/27, 8/22
3RA1210-1J.
8/17, 8/19
3RA1911-2
3RA1210-1JA
8/13, 8/15
3RA1912
3/65
3RA1210-1K.
8/17, 8/19
3RA1913
3RA1210-1KA
8/13, 8/15
3RA1921
7/27, 8/22
3RA1220-1C.
8/16, 8/18
3RA1922
3RA1220-1CB
8/12, 8/14
3RA1923
3RA1220-1D.
8/16, 8/18
3RA1924
3/63, 8/23
3RA1220-1DB
8/12, 8/14
3RA1931
7/27, 8/22
3RA1220-1E.
8/16, 8/18
3RA1932
3RA1220-1EB
8/12, 8/14
3RA1933
3RA1220-1F.
8/16, 8/18
3RA1941
7/27, 8/22
3RA1220-1FB
8/12, 8/14
3RA1942
3RA1220-1G.
8/16, 8/18
3RA1943
3RA1220-1GB
8/12, 8/14
3RA1952
3/63, 3/73
3RA1220-1H.
8/16, 8/18
3RA1953
3RA1220-1HB
8/12, 8/14
3RA1954
3/63
3RA1220-1J.
8/16, 8/18
3RA1962
3/63, 3/73
3RA1220-1JB
8/12, 8/14
3RA1963
3/64, 3/73
3RA1220-1K.
8/16, 8/18
3RA1972
3/63, 3/73
3RA1220-1KB
8/12, 8/14
3RA1973
3/64, 3/73
3RA1220-4A.25
8/17, 8/19
3RA2
3RA1220-4A.26
8/16, 8/18
3RA2
3RA1220-4AB25
8/13, 8/15
3RA1220-4AB26
8/12, 8/14
3RA1220-4B.25
8/17, 8/19
3RA1220-4B.26
8/16, 8/18
3RA1220-4BB25
8/13, 8/15
3RA1220-4BB26
8/12, 8/14
3RA1220-4C.
8/17, 8/19
3RA1220-4CB
8/13, 8/15
3RA1220-4D.
8/17, 8/19
3RA1220-4DB
8/13, 8/15
16
Siemens IC 10 AO 2014
16/23
Siemens AG 2014
Appendix
Article number index
Article No.
Page
3RB
Article No.
Page
3RH1131-2A
5/5
3RB1
3RH1131-2B
5/6
3RB20
7/49 ... 50
3RH1131-2H
5/11
3RB21
7/51
3RH1131-2J
5/12
3RB22
7/56
3RH1131-2K
5/12
3RB23
7/56
3RH1131-2M
5/11
3RB290
7/59
3RH1131-2V
5/12
3RB291
7/52
3RH1131-2W
5/12
3RB292
7/52
3RH1140-1A
5/5
3RB295
7/59
3RH1140-1B
5/6
3RB296
7/59
3RH1140-1H
5/11
3RB298
3RH1140-1J
5/12
3RH1140-1K
5/12
3RE
3RE10
9/4
3RH1140-1M
5/11
3RE13
9/4
3RH1140-1V
5/12
3RE19
9/4
3RH1140-1W
5/12
3RH1140-2A
5/5
3RH11
5/5
3RH1140-2B
5/6
3RH1122-1B
5/6
3RH1140-2H
5/11
3RH1122-1H
5/11
3RH1140-2J
5/12
3RH1122-1J
5/12
3RH1140-2K
5/12
3RH1122-1K
5/12
3RH1140-2M
5/11
3RH1122-1M
5/11
3RH1140-2V
5/12
3RH1122-1V
5/12
3RH1140-2W
5/12
3RH1122-1W
5/12
3RH12
3RH1122-2A
5/5
3RH1244-1A
5/5
3RH1122-2B
5/6
3RH1244-1B
5/6
3RH1122-2H
5/11
3RH1244-2A
5/5
3RH1122-2J
5/12
3RH1244-2B
5/6
3RH1122-2K
5/12, 5/14
3RH1262-1A
5/5
3RH1122-2M
5/11
3RH1262-1B
5/6
3RH1122-2V
5/12
3RH1262-2A
5/5
3RH1122-2W
5/12
3RH1262-2B
5/6
3RH1131-1A
5/5
3RH14
3RH1131-1B
5/6
3RH1422-1A
5/10
3RH1131-1H
5/11
3RH1422-1B
5/10
3RH1131-1J
5/12
3RH1431-1A
5/10
3RH1131-1K
5/12
3RH1431-1B
5/10
3RH1131-1M
5/11
3RH1440-1A
5/10
3RH1131-1V
5/12
3RH1440-1B
5/10
3RH1131-1W
5/12
16
3RH1122-1A
16/24
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
Article number index
Page
3RH19
Article No.
Page
3RT10
3RH1911-1A
3/35
3RT1015-1A
3/14
3RH1911-1B
3/36, 8/20
3RT1015-1B
3/18
3RH1911-1F
3/35, 8/20
3RT1015-1H
3/54
3RH1911-1G
5/7
3RT1015-1J
3/55
3RH1911-1H
3/34
3RT1015-1K
3/56
3RH1911-1L
3/35
3RT1015-1M
3/54
3RH1911-1M
3/36, 8/20
3RT1015-1V
3/55
3RH1911-1N
3/39
3RT1015-1W
3/56
3RH1911-2F
3/35
3RT1015-2A
3/14
3RH1911-2G
5/7
3RT1015-2B
3/18
3RH1911-2H
3/34
3RT1015-2H
3/54
3RH1911-2N
3/39
3RT1015-2J
3/55
3RH1921-1C
3/37, 8/20
3RT1015-2K
3/56
3RH1921-1D
3/38
3RT1015-2M
3/54
3RH1921-1E
3/38
3RT1015-2V
3/55
3RH1921-1F
3RT1015-2W
3/56
3RH1921-1H
3/34
3RT1016-1A
3/14
3RH1921-1J
3/38
3RT1016-1B
3/18
3RH1921-1K
3/38
3RT1016-1H
3/54
3RH1921-1L
3/37
3RT1016-1J
3/55
3RH1921-1M
3/37, 8/20
3RT1016-1K
3/56
3RH1921-1X
3/34
3RT1016-1M
3/54
3RH1921-2C
3/37
3RT1016-1V
3/55
3RH1921-2D
3/38 ... 39
3RT1016-1W
3/56
3RH1921-2E
3/38
3RT1016-2A
3/14
3RH1921-2F
3/36, 3/39
3RT1016-2B
3/18
3RH1921-2H
3/34
3RT1016-2H
3/54
3RH1921-2J
3/38 ... 39
3RT1016-2J
3/55
3RH1921-2K
3/38
3RT1016-2K
3/56
3RH1921-2X
3/34
3RT1016-2M
3/54
3RH1924
3/45
3RT1016-2V
3/55
3RT1016-2W
3/56
3RT1017-1A
3/14
3RT1017-1B
3/18
3RT1017-1H
3/54
3RT1017-1J
3/55
3RT1017-1K
3/56
3RT1017-1M
3/54
3RT1017-1V
3/55
3RT1017-1W
3/56
3RK
3RK
3/44, 5/9
3RP
3RP
7/60, 11/18
16
Article No.
Siemens IC 10 AO 2014
16/25
Siemens AG 2014
Appendix
Article number index
Page
Article No.
Page
3RT1017-2A
3/14
3RT1035-1A
3/16
3RT1017-2B
3/18
3RT1035-1B
3/20
3RT1017-2H
3/54
3RT1035-1X
4/16
3RT1017-2J
3/55
3RT1035-3A
3/16
3RT1017-2K
3RT1035-3B
3/20
3RT1017-2M
3/54
3RT1035-3K
4/15
3RT1017-2V
3/55
3RT1035-3X
4/16
3RT1017-2W
3/56
3RT1036-1A
3/16
3RT1023-1A
3/15
3RT1036-1B
3/20
3RT1023-1B
3/19
3RT1036-1X
4/16
3RT1023-3A
3/15
3RT1036-3A
3/16
3RT1023-3B
3/19
3RT1036-3B
3/20
3RT1024-1A
3/15
3RT1036-3K
4/15
3RT1024-1B
3/19
3RT1036-3X
4/16
3RT1024-1K
3/57
3RT1044-1A
3/17
3RT1024-3A
3/15
3RT1044-1B
3/21
3RT1024-3B
3/19
3RT1044-1X
4/16
3RT1024-3K
3/57
3RT1044-3A
3/17
3RT1025-1A
3/15
3RT1044-3B
3/21
3RT1025-1B
3/19
3RT1044-3K
4/15
3RT1025-1K
3/57
3RT1044-3X
4/16
3RT1025-1X
4/16
3RT1045-1A
3/17
3RT1025-3A
3/15
3RT1045-1B
3/21
3RT1025-3B
3/19
3RT1045-1X
4/16
3RT1025-3K
3RT1045-3A
3/17
3RT1025-3X
4/16
3RT1045-3B
3/21
3RT1026-1A
3/15
3RT1045-3K
4/15
3RT1026-1B
3/19
3RT1045-3X
4/16
3RT1026-1K
3/57
3RT1046-1A
3/17
3RT1026-1X
4/16
3RT1046-1B
3/21
3RT1026-3A
3/15
3RT1046-1X
4/16
3RT1026-3B
3/19
3RT1046-3A
3/17
3RT1026-3K
3RT1046-3B
3/21
3RT1026-3X
4/16
3RT1046-3K
4/15
3RT1034-1A
3/16
3RT1046-3X
4/16
3RT1034-1B
3/20
3RT105
3/22 ... 24
3RT1034-1X
4/16
3RT106
3/22 ... 24
3RT1034-3A
3/16
3RT107
3/22 ... 24
3RT1034-3B
3/20
3RT12
3RT1034-3K
4/15
3RT12
3RT1034-3X
4/16
16
Article No.
16/26
Siemens IC 10 AO 2014
3/27
Siemens AG 2014
Appendix
Article number index
Article No.
Page
3RT13
Article No.
Page
3RT1916-1B
3RT1316-1A
4/6
3RT1916-1C
3RT1316-1B
4/7
3RT1916-1D
3RT1316-2A
4/6
3RT1916-1E
3RT1316-2B
4/7
3RT1916-1G
3/44, 5/8
3RT1317-1A
4/6
3RT1916-1J
3/42, 5/8
3RT1317-1B
4/7
3RT1916-1L
3/42, 5/8
3RT1317-2A
4/6
3RT1916-1P
3/44
3RT1317-2B
4/7
3RT1916-2B
3/41, 5/9
3RT1325-1A
4/6
3RT1916-2C
3/41
3RT1325-1B
4/7
3RT1916-2D
3/41
3RT1326-1A
4/6
3RT1916-2E
3/40
3RT1326-1B
4/7
3RT1916-2F
3/40
3RT1336-1A
4/6
3RT1916-2G
3/40
3RT1336-1B
4/7
3RT1916-2L
3/40
3RT1344-1A
4/6
3RT1916-4B
3/48, 3/73
3RT1344-1B
4/7
3RT1916-4J
3/48, 5/9
3RT1346-1A
4/6
3RT1916-4K
3/47
3RT1346-1B
4/7
3RT1916-4M
3/46, 5/9
3RT1916-4R
3/47, 8/22
3RT14
3RT1446-1A
4/4
3RT1922
3/65
3RT1446-1B
4/4
3RT1924
3/49
3RT145
4/5
3RT1926-1B
3RT146
4/5
3RT1926-1C
3/42, 8/21
3RT147
4/5
3RT1926-1E
3/42
3RT1926-1Q
3/45
3RT15
3RT1516-1A
4/9
3RT1926-1T
3/42, 8/21
3RT1516-1B
4/9
3RT1926-2C
3/41
3RT1516-2A
4/9
3RT1926-2D
3/41
3RT1516-2B
4/9
3RT1926-2E
3/40
3RT1517-1A
4/9
3RT1926-2F
3/40
3RT1517-1B
4/9
3RT1926-2G
3/40
3RT1517-2A
4/9
3RT1926-2P
3/41
3RT1517-2B
4/9
3RT1926-3
3/44
3RT1526-1A
4/9
3RT1926-4B
3/48, 3/73
3RT1526-1B
4/9
3RT1926-4C
3/73
3RT1535-1A
4/9
3RT1926-4M
3/46
3RT1535-1B
4/9
3RT1926-4P
3/47
3RT1926-4R
3/47, 8/22
3RT16
3RT161
4/11
3RT1934-5
3/49 ... 50
3RT162
4/11
3RT1934-6
3/53
3RT164
4/11
3RT1935-5
3/49
3RT1935-6
3/53
3RT19
3/48
3RT1936-1
3/43, 8/21
3RT1900-1SB2
3RT1936-4B
3/48, 3/73
3RT1900-1SB6
3RT1936-4E
3RT1900-1SD
3RT1936-6
3/53
3RT1900-4
3/47, 8/22
3RT1936-7
3/53
16
3RT1900-1SB1
Siemens IC 10 AO 2014
16/27
Siemens AG 2014
Appendix
Article number index
Page
Article No.
3RT1944-5
3/50
3RU11
3RT1944-6
3/53
3RU1116-0AB
7/42 ... 43
3RT1945-5
3/50
3RU1116-0AC
7/44
3RT1945-6
3/53
3RU1116-0BB
7/42 ... 43
3RT1946-4B
3/48, 3/73
3RU1116-0BC
7/44
3RT1946-4E
3RU1116-0CB
7/42 ... 43
3RT1946-4F
3/45, 7/26
3RU1116-0CC
7/44
3RT1946-4G
7/26
3RU1116-0DB
7/42 ... 43
3RT1946-6
3/53
3RU1116-0DC
7/44
3RT1946-7
3/53
3RU1116-0EB
7/42 ... 43
3RT1954-6
3/53
3RU1116-0EC
7/44
3RT1954-7
3/53
3RU1116-0FB
7/42 ... 43
3RT1955-4
3RU1116-0FC
7/44
3RT1955-5
3/51 ... 52
3RU1116-0GB
7/42 ... 43
3RT1955-6
3/53
3RU1116-0GC
7/44
3RT1955-7
3/53
3RU1116-0HB
7/42 ... 43
3RT1956-1
3/43
3RU1116-0HC
7/44
3RT1956-4B
3/48, 3/73
3RU1116-0JB
7/42 ... 43
3RT1956-4E
3RU1116-0JC
7/44
3RT1956-4G
3RU1116-0KB
7/42 ... 43
3RT1956-6
3/53
3RU1116-0KC
7/44
3RT1956-7
3/53
3RU1116-1AB
7/42 ... 43
3RT1964-6A
3/53
3RU1116-1AC
7/44
3RT1964-6V
3/53
3RU1116-1BB
7/42 ... 43
3RT1964-7
3/53
3RU1116-1BC
7/44
3RT1965-5
3/51 ... 52
3RU1116-1CB
7/42 ... 43
3RT1965-6A
3/53
3RU1116-1CC
7/44
3RT1965-6V
3/53
3RU1116-1DB
7/42 ... 43
3RT1965-7
3/53
3RU1116-1DC
7/44
3RT1966-1
3/43
3RU1116-1EB
7/42 ... 43
3RT1966-4B
3/48, 3/73
3RU1116-1EC
7/44
3RT1966-4E
3RU1116-1FB
7/42 ... 43
3RT1966-4G
3RU1116-1FC
7/44
3RT1966-5
3/51 ... 52
3RU1116-1GB
7/42 ... 43
3RT1966-6A
3/53
3RU1116-1GC
7/44
3RT1966-6D
3/53
3RU1116-1HB
7/42 ... 43
3RT1966-6V
3/53
3RU1116-1HC
7/44
3RT1966-7
3/53
3RU1116-1JB
7/42 ... 43
3RT1975-5
3/51 ... 52
3RU1116-1JC
7/44
3RT1975-6A
3/53
3RU1116-1KB
7/42 ... 43
3RT1975-6V
3/53
3RU1116-1KC
7/44
3RT1975-7
3/53
3RT1976-6A
3/53
3RT1976-6D
3/53
3RT1976-6V
3/53
3RT1976-7
3/53
16
Article No.
16/28
Siemens IC 10 AO 2014
Page
Siemens AG 2014
Appendix
Article number index
Article No.
Page
Article No.
3RU1126-1
7/42, 7/44
3RV19
3RU1126-4
7/42 ... 44
3RV1901-0
7/18
3RU1136-1
7/42, 7/44
3RV1901-1
3RU1136-4
7/42 ... 44
3RV1901-2
7/18
3RU1146-4D
7/42, 7/44
3RV1902-1AB0
7/19
3RU1146-4E
7/42, 7/44
3RV1902-1AB4
7/19
3RU1146-4F
7/42, 7/44
3RV1902-1AF
7/19
3RU1146-4H
7/42, 7/44
3RV1902-1AM
7/19
3RU1146-4J
7/42 ... 44
3RV1902-1AP
7/19, 8/20
3RU1146-4K
7/42 ... 44
3RV1902-1AS
7/19
3RU1146-4L
7/42 ... 44
3RV1902-1AV
7/19
3RU1146-4M
7/42 ... 44
3RV1902-1D
7/19, 8/20
3RV1903
7/31
3RU19
Page
3RU1900-1
7/45, 7/52
3RV1908
7/25
3RU1900-2
7/45
3RV1912
7/19
3RU191
7/45
3RV1913
7/30 ... 31
3RU192
7/45
3RV1915-1
7/21
3RU193
7/45
3RV1915-2
7/21
3RU194
7/45
3RV1915-3
7/21
3RV1915-5
7/21
3RV10
3RV101
7/8 ... 9
3RV1915-6
7/22
3RV102
7/8 ... 9
3RV1917-1
7/34
3RV103
7/10
3RV1917-4
7/34
3RV104
7/10
3RV1917-5
7/34 ... 35
3RV11
3RV1917-6
7/35
3RV112
7/11
3RV1917-7
7/34 ... 35
3RV113
7/11
3RV1918
7/26
3RV114
7/11
3RV1921
7/19
3RV13
3RV1922
7/19
3RV132
7/12
3RV1923
7/30 ... 31
3RV133
7/12
3RV1925
3/73, 7/21
3RV134
7/12
3RV1927
7/34
3RV1928
7/19, 7/26
3RV1933
7/30
3RV1935-1
3/73, 7/21
3RV14
3RV14
7/13
3RV16
3RV1611-0
7/14
3RV1935-3
7/21
3RV1611-1
7/16
3RV1935-5
3/73, 7/21
3RV1935-6
7/22
3RV1936
7/24
3RV1938
7/19
3RV194
7/24
3RV17
7/15
3RV2
3RV2
7/24
16
3RV17
Siemens IC 10 AO 2014
16/29
Siemens AG 2014
Appendix
Article number index
Article No.
Page
3S
Article No.
Page
3TX
3SB
7/45, 7/52
3TX
3SX
7/45, 7/52
3ZX
3TK28
3ZX
3/46
8/25
11/17 ... 18
8US1
3TK2820-0
11/18
8US10
3TK2820-1
11/8
8US11
7/22
3TK2820-2
11/8
8US12
3TK2821
11/8
8US19
3TK2822
11/8
3TK2823
11/8
3TK2824
11/8
3TK2825
11/8
3TK2826-0
11/18
3TK2826-1
11/8
3TK2826-2
11/8
3TK2827
11/8
3TK2828
11/8
3TK283
11/9
3TK2840
11/12
3TK2841
11/12
3TK2842
11/12
3TK2845
11/12
3TK285
11/15
16
3TK281
16/30
Siemens IC 10 AO 2014
Siemens AG 2014
Appendix
16
Notes
Siemens IC 10 AO 2014
16/31
Siemens AG 2014
Appendix
Conditions of sale and delivery
1. General Provisions
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the
following Terms and Conditions of Sale and Delivery (hereinafter
referred to as "T&C"). Please note that the scope, the quality and
the conditions for supplies and services, including software
products, by any Siemens entity having a registered office
outside Germany, shall be subject exclusively to the General
Terms and Conditions of the respective Siemens entity. The
following T&C apply exclusively for orders placed with Siemens
Aktiengesellschaft, Germany.
1.1 For customers with a seat or registered office in
Germany
For customers with a seat or registered office in Germany, the
following applies subordinate to the T&C:
the "General Terms of Payment"1) and,
for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office in Germany"1) and,
for other supplies and services, the "General Conditions for
the Supply of Products and Services of the Electrical and
Electronics Industry"1).
1.2 For customers with a seat or registered office outside
Germany
For customers with a seat or registered office outside Germany,
the following applies subordinate to the T&C:
the "General Terms of Payment"1) and,
for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office outside of Germany"1) and
for other supplies and/or services, the "General Conditions for
Supplies of Siemens Industry for Customers with a Seat or
Registered Office outside of Germany"1).
16
2. Prices
The prices are in (Euro) ex point of delivery, exclusive of
packaging.
The sales tax (value added tax) is not included in the prices. It
shall be charged separately at the respective rate according to
the applicable statutory legal regulations.
Prices are subject to change without prior notice. We will charget
the prices valid at the time of delivery.
To compensate for variations in the price of raw materials (e.g.
silver, copper, aluminum, lead, gold, dysprosium and neodym),
surcharges are calculated on a daily basis using the so-called
metal factor for products containing these raw materials. A
surcharge for the respective raw material is calculated as a
supplement to the price of a product if the basic official price of
the raw material in question is exceeded.
The metal factor of a product indicates the basic official price
(for those raw materials concerned) as of which the surcharges
on the price of the product are applied, and with what method of
calculation.
An exact explanation of the metal factor can be downloaded at:
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
To calculate the surcharge (except in the cases of dysprosium
and neodym), the official price from the day prior to that on which
the order was received or the release order was effected is used.
To calculate the surcharge applicable to dysprosium and
neodym ("rare earths"), the corresponding three-month basic
average price in the quarter prior to that in which the order was
received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the
explanation of the metal factor).
16/32
Siemens IC 10 AO 2014
4. Export regulations
We shall not be obligated to fulfill any agreement if such
fulfillment is prevented by any impediments arising out of
national or international foreign trade or customs requirements
or any embargoes and/or other sanctions.
Export of goods listed in this catalog may be subject to licensing
requirements. We will indicate in the delivery details whether
licenses are required under German, European and US export
lists. Goods labeled with "AL" not equal to "N" are subject to
European or German export authorization when being exported
out of the EU. Goods labeled with "ECCN" not equal to "N" are
subject to US re-export authorization.
The export indications can be viewed in advance in the
description of the respective goods on the Industry Mall, our
online catalog system. Only the export labels "AL" and "ECCN"
indicated on order confirmations, delivery notes and invoices
are authoritative.
Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i .a. due to the final disposition and
intended use of goods.
If you transfer goods (hardware and/or software and/or
technology as well as corresponding documentation, regardless
of the mode of provision) delivered by us or works and services
(including all kinds of technical support) performed by us to a
third party worldwide, you must comply with all applicable
national and international (re-)export control regulations.
If required for the purpose of conducting export control checks,
you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively
works and services provided by us, as well as to any export
control restrictions existing in this relation.
The products listed in this catalog may be subject to
European/German and/or US export regulations. Any export
requiring approval is therefore subject to authorization by the
relevant authorities.
Errors excepted and subject to change without prior notice.
Siemens AG 2014
Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices
listed at www.siemens.com/automation/partner
System Solutions for Industry
Interactive Catalog on DVD
Catalog
ET G1
D 11
D 12
D 15.1
D 18.1
D 21.3
D 23.1
D 23.2
D 31
D 84.1
D 86.1
D 86.2
DA 12
DA 21.1
DA 21.2
DA 22
DA 45
DA 48
DA 51.2
DA 51.3
DA 65.10
DA 65.11
DA 65.3
DA 65.4
D 81.1
D 87.1
MD 50.1
MD 50.11
MD 10.1
MD 10.2
MD 30.1
MD 31.1
FI 01
MP 31
WT 10
PA 01
PA 11
Catalog
LV 10
Motion Control
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools
SINUMERIK & SINAMICS
Equipment for Machine Tools
SINUMERIK 840D sl Type 1B
Equipment for Machine Tools
SINUMERIK 808
Equipment for Machine Tools
SINUMERIK 828
Equipment for Machine Tools
SIMOTION, SINAMICS S120 & SIMOTICS
Equipment for Production Machines
Drive and Control Components for Cranes
LV 11
LV 35
LV 36
LV 50
LV 51
LV 52
LV 56
LV 70
ET D1
NC 60
NC 61
NC 62
NC 81.1
NC 82
PM 21
CR 1
Power Supply
Power Supply SITOP
KT 10.1
Safety Integrated
Safety Technology for Factory Automation
SI 10
ST 80/
ST PC
SIMATIC Ident
Industrial Identification Systems
ID 10
ST 70
ST PCS 7
ST PCS 7 T
ST PCS 7 AO
SIMATIC NET
Industrial Communication
IK PI
IC 10
Siemens AG 2014
Industrial Security
Siemens provides products and solutions with
industrial security functions that support the
secure operation of plants, solutions, machines,
equipment and/or networks. They are important
components in a holistic industrial security
concept. With this in mind, Siemens products
and solutions undergo continuous development.
Siemens recommends strongly that you regularly
check for product updates.
For the secure operation of Siemens products
and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept)
and integrate each component into a holistic,
state-of-the-art industrial security concept. Thirdparty products that may be in use should also be
considered. For more information about industrial
security, visit
http://www.siemens.com/industrialsecurity.
Weitere Informationen
Control Components and Systems Engineering:
www.siemens.com/sirius
Siemens AG
Industry Sector
Control Components and
Systems Engineering
Postfach 2355
90713 FRTH
GERMANY
www.siemens.com/automation