Flowsic300: Non-Custody Transfer Measurement and Process Monitoring
Flowsic300: Non-Custody Transfer Measurement and Process Monitoring
Flowsic300: Non-Custody Transfer Measurement and Process Monitoring
FLOWSIC300
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
8016137/2014-09
Subject to change without notice
Maximum reliability
Simple installation
Powerful software
The lack of a meter body reduces investment costs in particular with line sizes
over 12 inches. After the installation,
only the equipment that is absolutely
essential remains on the pipeline. For
sensor replacement during operation, a
ball valve only forms part of the optional
sensor extraction tool that is suitable for
different measuring points.
Product overview
The FLOWSIC300 is available in 1-path and 2-path configurations. The 1-path configuration is ideal for installation onto
pipes with small nominal diameters and for basic control measurements. The 2-path configuration offers a higher level of
accuracy, in particular with flow disturbances. Suitable for installation and sensor replacement during ongoing operations
is the universal sensor extraction tool that offers maximum security with pressure lock. For the highest possible measurement accuracy and ease-of-use, the FLOWSIC300 can be pre-installed and calibrated at SICK in a pipe section (spool).
1-path configuration
8016137/2014-09
Subject to change without notice
2-path configuration
Higher measurement
accuracy
Ideal for diameters over
12 inches
Increased resistance to
flow disturbances
Maximum measurement
accuracy
Complete configuration
at factory
Easy installation on site
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
At a glance
Quality components
Modular flexible installation
Non-contact ultrasonic technology
without pressure loss
Your benefits
Reliable flow measurement for checking purposes
Simple installation into existing
pipelines
Efficient solution, especially for pipe
diameters over 12inches, thanks to
installation onto existing pipelines
and without need for a meter body
Reduced acquisition costs the
sensor extraction tool can be used
for multiple devices
Additional information
Fields of application 5
Detailed technical data5
Measuring ranges6
Ordering information7
Dimensional drawings7
-- www.mysick.com/en/FLOWSIC300
For more information, just enter the link and get direct access to technical data, CAD design models, operating
instructions, software, application examples and much more.
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
8016137/2014-09
Subject to change without notice
A
B
C
D
E
F
Fields of application
Gas flow measurement in non custody transfer applications
Control measurements in the field of natural gas transfer
and storage
System
Measured values
Measurement principle
1, 2
Measuring medium
Measuring ranges
Gas velocity
0.3... 60m/s
Depending on the nominal size of the pipe
Measuring span
Max. 1: 130
Repeatability
Uncertainty of measurement
1%... 5%
Of the measured value (depending on device configuration)
Gas temperature
40C... +180C
Operating pressure
Ambient temperature
40C... +60C
Storage temperature
40C... +70C
Ambient humidity
95%
Relative humidity; non-condensing
Ex-approvals
ATEX
IECEx
CSA
Electrical safety
Enclosure rating
Sender/receiver units
SPU control unit
IP68
IP65/ IP67
Analog outputs
1output:
4... 20mA, 200
Active/passive, electrically isolated
Digital outputs
3outputs:
Passive, electrically isolated, Open Collector or according to NAMUR (EN50227), fmax= 6kHz
(scalable)
Interfaces
Bus protocol
8016137/2014-09
Subject to change without notice
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
H
I
J
K
L
M
N
O
P
Q
R
S
T
A
B
C
D
E
F
Dimensions (Wx Hx D)
Weight
Mounting
Electrical connection
Voltage
Power consumption
12... 28.8V
With active analog output: 15... 28.8V
<
Measuring ranges
System
Inner diameter,
typical
Nominal size
H
I
J
K
L
M
N
O
P
Q
R
S
T
Maximum velocity
mm
m/h
ft/h
m/s
4"
102.3
1,700
59,500
60
DN 150
6"
154.1
3,300
115,500
50
DN 200
8"
202.7
5,200
182,000
45
DN 100
DN 250
10"
254.4
7,300
255,500
40
DN 300
12"
304.8
8,600
301,000
33
DN 350
14"
336.6
10,500
367,500
33
DN 400
16"
387.4
14,000
490,000
33
DN 450
18"
438.2
17,900
626,500
33
DN 500
20"
489
22,300
780,500
33
DN 600
24"
590.6
32,500
1,137,500
33
DN 700
28"
692.2
40,600
1,421,000
30
DN 750
30"
743
46,800
1,638,000
30
DN 800
32"
793.8
53,400
1,869,000
30
DN 900
36"
895.4
68,000
2,380,000
30
DN 1000
40"
992.2
83,500
2,922,500
30
DN 1050
42"
1,043
92,200
3,227,000
30
DN 1100
44"
1,093.8
94,700
3,314,500
28
DN 1200
48"
1,195.4
109,000
3,815,000
27
DN 1300
52" *
1,290
122,300
4,280,500
26
DN 1400
56" *
1,390
136,500
4,777,500
25
The maximum volume flow may be additionally limited by the operation pressure and damping effects.
* Not standardized according to ANSI B36.10.
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
8016137/2014-09
Subject to change without notice
A
B
C
D
E
F
Ordering information
Our regional sales organization will help you to select the optimum device configuration.
341 (13.43)
201 (7.91)
114.3 (4.50)
168 (6.61)
351 (13.82)
170 (6.69)
150 (5.91)
8016137/2014-09
Subject to change without notice
150 (5.91)
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
H
I
J
K
L
M
N
O
P
Q
R
S
T
834 (32.83)
Installation
60
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
291 (11.46)
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
8016137/2014-09
Subject to change without notice
NOTES
8016137/2014-09
Subject to change without notice
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
NOTES
10
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
8016137/2014-09
Subject to change without notice
SERVICES
Product
Applications
Literature
Service
Accessories
Software
8016137/2014-09
Subject to change without notice
F L O W S I C 3 0 0 G a s flow m e t e r s | S I C K
11
SICK AT A GLANCE
SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 6,500 employees and over 50 subsidiaries and equity investments as well as numerous representative offices worldwide, we are always close to our customers. A unique range of products and services
creates the perfect basis for controlling processes securely and efficiently, protecting individuals from
accidents and preventing damage to the environment.
We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.
Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.
For us, that is Sensor Intelligence.
Worldwide presence:
Australia, Austria, Belgium/Luxembourg, Brazil, Czech Republic, Canada, China, Denmark, Finland, France,
Germany, Great Britain, Hungary, India, Israel, Italy, Japan, Mexico, Netherlands, Norway, Poland, Romania,
Russia, Singapore, Slovenia, South Africa, South Korea, Spain, Sweden, Switzerland, Taiwan, Turkey, United
Arab Emirates, USA
Detailed addresses and additional representatives
- www.sick.com