A10VSO18 Bomba Hidraulica
A10VSO18 Bomba Hidraulica
A10VSO18 Bomba Hidraulica
Hydraulics
Electric Drives
and Controls
Pneumatics
Service
Automation
Mobile
Hydraulics
RE 92 712/10.07 1/16
Replaces: 02.94
open circuit
Size 18
Series 31
Nominal pressure 280 bar
Peak pressure 350 bar
Contents
Features
Ordering code
Hydraulic fluid
Technical data
7
8
10
11
12
13
14
15
2/16
A10VSO | RE 92 712/10.07
Ordering code
A10VS O 18
Hydraulic fluid
Mineral oil (without short code)
31
prefered program
with short delivery times
type list see page 15
A10VS
Mode of operation
O
18
Control device
Pressure controller
DR
DR
DR
DRG
DFR
DFR1
DFE1
remote controlled
Pressure and flow controller
DFR
DFR
X-channel plugged
Pressure and flow controller, electronic
DFE1
Series
31
Direction of Rotation
Viewed on drive shaft
clockwise
anti-clockwise
Seals
Perbunan (shaft sealing ring in Viton)
Viton
Shaft end
DIN
SAE
Splined
Splined
Mounting flange
ISO 2-hole
SAE 2-hole
12
Pressure port B
Suction port S
62
Through drive
Without through drive
N00
With through drive for building on axial piston unit or gear pump
Mounting flange
Shaft/coupling
for mounting:
82-2 (SAE A)
G2
K01
= available
82-2 (SAE A)
A10VSO 18
K52
= in preparation
= not available
RE 92 712/10.07 | A10VSO
3/16
Hydraulic fluid
For detailed information on the range of fluids and their
ambient temperature.
Viscosity limits
temperatures.
Fluid filtration
min = 10 mm2/s
short-term at maximum permissible drain temperature
of 90 C.
tmin = 25 C
tmax = + 90 C
Selection diagram
0
20
20
60
40
80
1000
600
400
100
80
60
40
36
opt
Viscosity
(mm2/s)
Viskositt
(mm2/ s)
68
46
32
22
0
10
VG
VG
VG
VG
VG
200
100
1000
20
15
10
- 25
16
- 10
10
30
50
70
90
10
Temperature
Temperatur
t ( C)
t (C)
Combination pumps
1. If a second Brueninghaus pump is fitted in the factory, both ordering codes should be joined with "+" .
4/16
A10VSO | RE 92 712/10.07
Technical data
(suitable for operation on mineral oil;
for water based fluids see RE 90223 and
environmentally acceptable fluids see RE 90221)
Determination of inlet pressure pabs at suction port S or
reduction in output flow for increasing speed
0,8 bar
30 bar
280 bar
350 bar
1,6
Speed n/nmax
1,2
1,4
1,1
1,2
1,0
1,0
Case drain pressure
Maximum permissible pressure of case drain fluid (at port L, L1):
Maximum 0.5 bar higher than inlet pressure at port S,but no
higher than 2 bar absolute.
0,9
0,9
0,7
0,8
0,9
0,8
1,0
18
Displacement
Max. speed1)
at Vg max
Vg max
cm
18
no max
rpm
3300
no max zul
rpm
3900
Qo max
L/min
59,4
L/min
27
kW
27,7
kW
12,6
80,1
at no max
at nE = 1500 rpm
Po max
Max.power
(p = 280 bar)
at no max
at Vg max
Mmax
Nm
at Vg max
Nm
at nE = 1500 rpm
Fill capacity
28,6
2
kgm
0,00093
0,4
kg
12
Fax max
700
Fq max
350
) These values are valid for an absolute pressure of 1 bar at suction port S.
By reducing the output flow or increasing the input pressure
the speed can be increased as shown in the diagram.
Application of
Fq
forces
Fax
X/2 X/2
Determination of size
Flow
Q=
Drive torque
M=
Drive capacity
P=
Vg n v
[L/min]
1000
1,59 Vg p
[Nm]
100 mh
2 M n
60000
Mn
9549
Qp
600 t
[kW]
Vg
p
n
v
mh
t
RE 92 712/10.07 | A10VSO
5/16
Installation notes
The installation position is optional. The pump housing must be filled with hydraulic fluid during commissioning and stay full when
operating. In order to ensure the lowest possible noise values all connections (suction, pressure and drain connections) must
be flexible.
Avoid a non-return valve in the drain line. In exceptional cases this may be permissible, but only after prior consultation with us.
For detailed installation notes and commissioning information see RE 90400 (in prep.)
74
72
Qmax
70
Qzero
68
n = 3000 rpm
Qmax
66
Qzero
64
n = 1500 rpm
62
60
58
56
0
50
100
150
200
250
280
80
60
PQ max
40
20
PQ zero
0
0
Size 18
n = 1500 rpm
n = 3300 rpm
50
100
150
200
250
280
Operating pressure p [bar]
30
25
20
15
10
5
0
Flow Q [L/min]
(Fluid:
Hydraulic oil ISO VG 46 DIN 51519, t = 50 C)
6/16
A10VSO | RE 92 712/10.07
Before finalising your design, please request a certified drawing.
All rights reserved, subject to revision
V
L
2 hole flange
L1
W
View W
View V
S
M10
17
17deep
tief
B
S
L/L1
Pressure port
Suction port
Case drain ports
SAE 3/4"
SAE 1"
M16x1,5
B
M10
17
17deep
tief
RE 92 712/10.07 | A10VSO
V
L
2 hole flange
L1
16-4 (SAE A)
16/32DP; 9 T
View W
View V
S
20 deep
B
20 deep
3/4"
22
30
38
B
S
L/L1
Pressure port
Suction port
Case drain ports
7/16
SAE 3/4"
SAE 1"
9/16-18 UNF-2B
8/16
DR
A10VSO | RE 92 712/10.07
Before finalising your design, please request a certified drawing.
All rights reserved, subject to revision
Pressure controller
Static curve
(at n1 = 1500 rpm; toil = 50 C)
Flow Q
S
Setting range
20
280
Operating pressure p [bar]
Dynamic Curves
The operating curves are measured mean values taken under
test conditions with the unit mounted inside the tank.
Conditions: n = 1500 rpm
toil = 50 C
Pressure cut-off at 350 bar
Load steps were obtained by suddenly opening and closing the
pressure line with a pressure relief valve as load valve 1 m from
the mounting flange of the axial piston unit.
350
Ports
B
S
L, L1
L1
Pressure port
Suction port
Case drain ports( L1 plugged)
Controller data
Hysteresis and pressure increase p __________ max. 4 bar
Pilot oil requirement _______________ max. approx. 3 L/min
Loss of flow at Qmax see page 5.
Control time
Size
18
tSA (ms)
at 50 bar
50
tSA (ms)
at 220 bar
tSE (ms)
zero stroke 280 bar
25
20
Unit dimensions
300
250
200
150
100
50
104,5
Displacement
(swivel angle)
Vgmax
V gmin
Control time t
Control time (out) tSA
View Y
125,5
DFR valve, flow controller blocked and not tested
RE 92 712/10.07 | A10VSO
9/16
DRG
Not included in
supply
Flow Q
Ports
B
S
L, L1
X
Setting range
Pressure port
Suction port
Case drain ports ( L1 plugged)
Pilot pressure port
Unit dimensions
20
A5 (SAE)
280
Operating pressure p [bar]
Threaded
connection
7/16-20 UNF-2B
A5 (ISO)
Controller data
Hysteresis and pressure increase p __________ max. 4 bar
Pilot oil requirement __________________ approx. 4.5 L/min
Loss of flow at Qmax see page 5.
A4
A1
View Y
Size
A1
A2
A3
A4
A5
Port X
40
40
A3
A2
10/16
DFR/DFR1
A10VSO | RE 92 712/10.07
Not included
in supply
Plugged on
DFR 1
Flow Q
Q (see table)
Adjustment range
20
280
Operating pressure p [bar]
S
L1
Flow Q
Q (see table)
Connections
B
S
L, L1
X
350
300
280
250
Displacement Vg %
100
75
200
50
150
100
25
Speed n
Dynamic flow control curve
The curves are mean values measured under test conditions,
pump in tank
50
18
(stand by)
Control time t
Control time (out) tSA Control time (in) tSE
Control time
Size
tSA (ms)
tSA (ms)
tSE (ms)
stand by-280 bar 280 bar-stand by 50 bar-stand by
18
40
15
40
Pressure port
Suction port
Case drain ports ( L1 plugged)
Pilot pressure port
Differential pressure p:
Adjustable between 10 and 22 bar (higher values on request).
Standard setting: 14 bar. If another setting is required please
state in clear text.
When pressure is relieved on port X to tank a stalled pressure
of p = 18 2 bar ("stand by") is set.
Controller data
Max. flow deviation (hysteresis and increase)
measured at drive speed n = 1500 rpm
Size
Qmax
L/min
18
0,9
RE 92 712/10.07 | A10VSO
11/16
Unit dimensions
A5 (SAE)
Threaded
connection
7/16-20 UNF-2B
A5 (ISO)
Adjustment screw
for flow controller
differential pressure
A4
A1
A3
A2
Pilot valve installed here
for anti-clockwise rotation
Size
A4
A5
A1
A2
A3
40
Port X
40
12/16
A10VSO | RE 92 712/10.07
1.1
B
1.2
Static curves
End of control
Ports
B
S
L, L1
Flow Q [%]
100
L1
Pressure port
Suction port
Case drain ports ( L1 plugged)
Components
1
A10VSO with hydraulic setting device
1.1 Proportional valve
1.2 Inductive positional transducer
Pressure sensor and control electronics are loose items
(please order separately to RE 67016)
12
280
Control data
Hysteresis
< 1% of Vg max
Repeatability
< 1%
160
140
120
100
80
60
Dynamic curves
Pressure stepped signal value e.g. 40 bar 120 bar
DFE1 45 with compression oil volume (5L)
psoll
comm.
pist
act.
40
20
0
160
140
120
100
80
pist
act.
60
40
psoll
comm.
20
0
50 ms
Control time
50 ms
Control time
RE 92 712/10.07 | A10VSO
Unit dimensions
DFE1 pressure and flow controller, electronic
Size
A1
A2
A3
18
97
106,5 118
A4
A5
158 63
A6
216
13/16
14/16
A10VSO | RE 92 712/10.07
Before finalising your design, please request a certified drawing.
All rights reserved, subject to revision
Through drive
The A10VSO axial piston unit can be supplied with through drive
in accordance with the coding on page 3.
The type of through drive is determined by the coding (KXX).
m2
m3
l1
Combination pumps
By building on other pumps mutually independent circuits can be
made available for use.
1.
If the combination pump consists of 2 Brueninghaus
units and if these are to be supplied assembled
then the two ordering codes should be joined with "+".
Typical order:
A10VSO 18 DR/31 RPSC12K52 +
A10VSO 18 DR/31 RPSC12N00
2.
l2
l3
m1, m2 [kg]
l1, l2 [mm]
Weight of pump
Centre to centre spacing
Mm = (m1 x l1 + m2 x l2 + m3 x l3) 1 [Nm]
102
Size
18
50
Weight
kg
12
l1
mm 90
MGes
total
MGes
total
MD2
MD1
MD1
Size
MD2
18
Permitted.through
MD1max Nm
80
drive torque.
MD2max Nm
Permitted.through
MD1max Nm
drive torque.
MD2max Nm
80
A10VSO + A10VSO
A1
A2
A3
A4
Main p.
A10VSO 18
2nd pump
A2 A3 A4 A1
A10VSO 18
A2
A10VSO 28
A3 A4 A1
A2
A10VSO 45
A3 A4 A1
A2
A10VSO 71
A3 A4 A1
A2
A10VSO 100
A3 A4 A1
A2
A10VSO 140
A3 A4
164 204 349 399 164 204 349 399 184 229 374 424 217 267 412 462 275 338 483 533 275 350 495 545
See RE 92711
RE 92 712/10.07 | A10VSO
15/16
Built-on A10VSO 18
Order code K01 or K52
A5
A4
A6
45 o
A7
nur Konly
01
K01
A8
A9
A3
A2
up to pump mounting surface
Size
A2
A3
A4
A5
A6
K01
182
10
43,3
M10;16 deep
spline SAE A,
5/8";
16/32DP; 9T
82,55
106,5
K52
182
10
43,3
M10;16 deep
3/4";
16/32DP; 11T
82,55
106,5
Type
947666
A10VSO 18 DFR
/31L-PSC62N00
940520
A10VSO 18 DFR
/31R-PPA12N00
945178
A10VSO 18 DFR1
/31R-PPA12N00
942503
A10VSO 18 DR
/31R-PPA12N00
A7
A8
A9
16/16
A10VSO | RE 92 712/10.07