RPS 5.19 SP1 Release Notes
RPS 5.19 SP1 Release Notes
RPS 5.19 SP1 Release Notes
D5500CU
en
Introduction | en
Introduction
Notice!
After system installation and any control panel programming, perform a complete system test.
A complete system test includes testing the control panel, all devices, and communication
paths for proper operation.
1.1
About documentation
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by
copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
1.2
Compatibility
RPS supports the following control panels:
B5512/B4512/B3512
D2000 Series: D2212, D2112, D2012. To program a D2412 or D2812 control panel, use
the D2212 control panel account.
D4112/D6112
D6412/D4412
D9112B1/D7212B1
DS7240, DS7220
DS7240V2-EXP/DS7240V2-FRA/DS7240V2-SWE/DS7240V2-UK, DS7220V2-EXP/
DS7220V2-FRA/DS7220V2-SWE/DS7220V2-UK, CC7240-AUS, DS7240/DS7220,
DS7240csc, DS7240-EXP/DS7240-HUN/DS7240-NOR/DS7240-SPA (v1.52 and higher)/
DS7240-SPA (v1.05)/DS7240-SWE/DS7240-UK, DS7220-SPA
FPD-7024, D7024/DS9400, D9124 Fire Alarm Control Panels (FACP). Use the
D9124default.dsf file on the RPS CD-ROM to create a D9124 account.
Depending on your installation, some of these control panels might not be accessible.
2014.05 | 34 | F01U045283
2.1
Installation notes
Notice!
If you have already installed RPS version 5.19.3, go to Service Pack installation notes, page
4.
Directory Installation. Do not install RPS in a directory with a space in its name (for
example, Program Files).
Update Operating System Message when Installing SQL Express. If you install SQL
Express on any non-English version of Windows XP SP3, a dialog might appear
recommending you to update your operating system. This message can be ignored. Click
OK to continue installing SQL Express.
Cannot Update System File Message when Installing SQL Express. When installing SQL
Express on a non-English version of Windows XP SP3, the following error message might
appear:
The Windows Installer service cannot update the system file C:\WINDOWS
\system32\msxml6r.dll because the file is protected by Windows.
If this error message appears, cancel the installation and perform the following steps:
Make a backup copy of the system registry. Navigate to the registry key on the RPS CD-ROM at
X:\Windows File Protection Registry Update. X refers to the letter assigned to the
computers CD-ROM drive. Double-click the WindowsFileProtection.reg file. Restart the
computer and reinstall SQL Express.
Corrupt Account Database on a Turkish Operating System. If you change the original
settings of the RPS computer after installing RPS on a Turkish version of a supported
Windows operating system, the account database will become corrupted.
2.2
2.
3.
2014.05 | 34 | F01U045283
2.3
1.
2.
3.
Operation notes
Creating a GV4 Series control panel account. When creating a new GV4 Series control
panel account inRPS, be sure to select the correct firmware version on the Panel Info tab
on the Panel Data New window.
Figure 2.1: GV4 Panel Version (v1.00 thru v1.99 or v2.00 or greater)
Creating a GV3 Series control panel account: When creating a new GV3 Series control
panel account in RPS, be sure to select the correct firmware version on the Panel Info
tab on the Panel Data New window.
2014.05 | 34 | F01U045283
3.1
What's new?
3.1.1
Dual Authentication. The keypad has a credential reader for cards, tokens, and keyfobs.
Users must present any two forms of authorization in order to gain access.
Presence Sensor. The keypad has a presence sensor that detects motion within close
proximity to the keypad and brightens a dimmed display as a user approaches.
Login Only. When a user logs in, the control panel toggles to the configured user
language, and silences any bells.
Login/Disarm. When using this feature, the control panel toggles to the configured user
language, deactivates any active bells, and disarms any armed areas within the scope of
the keypad in reference to the authority level of the designated user.
3.1.2
B442 and B443 Plug-in Cellular modules. Improved diagnostic support for Plug-in
Cellular modules includes reporting of the data class of the current connection for control
panels version 2.03 and higher.
RPS is now able to automatically detect the type of cellular module that is plugged into
the control panel.
Signal strength is shown as both a qualitative value and actual value in dbm.
Carrier name (for control panels version 2.03 and higher).
B942. New diagnostics support for B942 points, outputs, and keypad specific
information.
IP cameras. New diagnostics support for IP cameras shows the current state of the
camera and the integrity of the connection. (The B3512 and the E variants do not support
IP cameras.)
2014.05 | 34 | F01U045283
B442 Conettix Plug-in GPRS Cellular Communicator (intended for Europe, Latin America,
Middle East, Australia, and China)
B443 Conettix Plug-in HSPA+ Cellular Communicator (intended for Canada, Europe, and
Middle East)
Fully integrated with the control panel for firmware updates, configuration and status
monitoring over SDI2
RF module support
The RF module type (RADION or Inovonics) is now automatically discovered by the control
panel and populated in RPS . After connecting an RF module, receive data from the control
panel to RPS to save the selected type to the control panel account.
Personal notifications
Two new Personal Notification Methods added. New options include notification by SMS text
message or email message through the B426 Conettix Ethernet Communication Module and
B450 Conettix Plug-in Communicator Interface.
3.2
Corrections
RPS versions 5.18 to 5.19.3 had an issue connecting more than once with the FPD-7024.
The second attempt to connect to the control panel might result in an error 10057. RPS
version 5.19.4 corrects this issue.
When updating RPS version 5.11 to RPS 5.19.3 you might not be able to connect with
GV2 control panels due to an error with converting the Datalock database table from the
older version of RPS. RPS version 5.19.4 corrects this issue.
The display of the Open/Close windows programming would cut off some of the calendar
view when run on some Dell computers. RPS version 5.19.4 corrects this issue.
When the Central Station Encryption was configured with RPS 5.19.3, error 12001
occurred when using a GV2, GV3 panel with a DX4020 communication module. RPS
version 5.19.4 corrects this issue.
Previously, backing up the database using the File > Backup created an incompatible
database backup XML file. RPS version 5.19.4 corrects this issue.
The Receiver Supervision Time settings changed so that the Ack Wait times are not
excessive when using the B450 with GSM modem (B443). Excessive Ack Wait times can
cause possible missed events.
Backing up the database using the File > Backup created an incompatible database
backup XML file. RPS version 5.19.4 corrects this issue.
Restart Time (formerly Verify Time) data range changed in GV4 v2 and B Series control
panels to 5-55 seconds.
2014.05 | 34 | F01U045283
When setting View/Edit levels for User Passcodes, it is recommended that this level is
also configured at the same level as Mask User Passcode. If you have used a View/Edit
level higher than the Mask User Passcode, it is possible for a user with a level below the
View/Edit level to view user passcodes through panel reports. This will be resolved in the
next release of RPS
Support for B5512/B4512/B3512 USB direct connect. USB direct connect uses a serial
port assignment on the connected computer. RPS only supports COM ports 1 through 16.
If Windows automatically assigns a COM port higher than 16, reassign a COM port
previously assigned but no longer in use (Windows might present an unused COM port as
still in use). Refer to release com ports in Microsoft's technical forums at http://
social.technet.microsoft.com/Forums/en-US/w7itprohardware/thread/e1ba4f5eaf63-40e5-855a-c513f5013ec6.
For the B5512/B4512/B3512 on-board USB connection, the USB drivers might not
automatically install when you connect the USB cable from the computer to the control
panel. When you connect the USB for the first time, the Found New Hardware (Not
Responding) dialog box might appear, depending on the operating system. If it does, click
the Locate and install driver software (recommended) option. Windows locates the
drivers automatically; RPS installs the drivers in the proper folder with the other USB
drivers. Notice! The RPS USB driver is named USB, RPS to Bosch ST-IN CP. Once
configured, the computer remembers the proper configuration the next time you connect
the control panel using USB. When installed properly, the USB driver is listed in the
Device Manager under Ports (COM & LPT).
Modem baud rate for GV4 Series and B Series control panels. D9412GV4/D7412GV4 and
B5512/B4512/B3512 control panels can communicate via Modem at 2400 baud rate, but
the UOM operation only communicates at 1200 baud. RPS operates in UOM mode with
only one baud rate, and to be backward compatible with older control panels, RPS uses
1200 baud. When setting a control panel for UOM, configure PANEL WIDE PARAMETERS
> RPS Parameters > RPS Modem Speed to 1200.
4.1
Windows Server 2003 Win Installer 3.1 Error Message. During the installation of RPS, Win
Installer 3.1 shows a failed installation message when installing RPS on a Windows Server
2003 computer.
Windows 7 DX4010V2 Driver Update. When upgrading an existing version of the RPS on a
Windows 7 computer, the driver for the DX4010V2 does not automatically update to the
latest version. If it is required, manually install the file now located on the CD.
4.2
Firmware version shows after refresh. After firmware update, the Panel View window
does not immediately show the correct firmware value. Press [F5] to refresh the screen
to display the correct firmware version.
2014.05 | 34 | F01U045283
Language Settings for Windows Users Without Admin Rights. If a Windows user who does
not have admin rights on the RPS computer changes the default language setting (for
example, from English to Spanish), the change is not preserved when RPS is closed and
restarted. The setting reverts to the default language.
Changing the Computers Regional Settings Affects Date Displays. If you change your RPS
computers regional settings, some date displays might not appear correctly.
Invalid Messages. Some modems can cause RPS to generate an invalid RPS passcode
message as a result of a busy phone line. Calling an invalid control panel type (for
example, a D7024 account calling a D6412 control panel) does not always cause RPS to
generate an Invalid Panel Type error message. An Invalid RPS Passcode message might
appear instead.
RPS and Door Access Control Module (DACM) Software Compatibility. If you install RPS
and the DACM software on the same computer, the DACM software might not start.
Uninstall the DACM software, and then reinstall it.
Importing Accounts from Older Versions of RPS. Accounts imported from older versions
of RPS do not appear in the Panel List regardless of a successful import message from
RPS . This issue applies only to non-English versions of RPS installed on compatible
Microsoft Windows operating systems.
4.3
Windows Users Without Admin Rights Cannot Turn Unattended Service On or Off.
Windows users who do not have admin rights on the RPS computer cannot turn
Unattended Service on or off.
UOM and Hayes 1200 Modem. Starting with RPS 5.13, the Hayes 1200 Modem is no
longer supported for Unattended Over Modem (UOM) operation.
UOM Init String for a GV3 Series or DS7400XiV4 Account. When using Unattended Over
Modem (UOM) with a GV3 Series or DS7400XiV4 control panel account, use the modem
init string for the DS7400XiV4 control panel.
Baud Rates for Panel-initiated Unattended Over Modem (PI-UOM). PI-UOM can only use
1200 baud. Baud rates of 300 and 2400 are currently not supported.
4.4
Printing the Program Record Sheet (PRS). RPS might add extra blank pages when
printing the PRS to the .rtf file format. Some PRS reports printed in .pdf or .rtf format
might show unaligned data.
2014.05 | 34 | F01U045283
10
RPS Uses Default Printer for All But First Report in Multiple Report Group. When printing
multiple control panel reports, RPS sends only the first report to a selected printer other
than the default printer. All subsequent reports in the request are sent to the default
printer.
Resizing Saved Exported Reports. To print a saved exported file correctly, some manual
resizing might be required for the selected printer.
4.5
GV4 v2.03. RPS diagnostics for the B450 Conettix Plug-in Communicator Interface are
only available when the module is set to address 1. When the module is set to address 2,
the B450 Conettix Plug-in Communicator Interface is fully functional, however, RPS
diagnostics are not available.
GV4 v1.x. RF diagnostics signal strength for GV4 v1.x shows 0s when connected via
modem. There are no known issues with IP connections.
4.6
GV3 Series v8.10 or greater and Hayes or Securcomm Modem Baud Rate Settings. If you
set the baud rate in the control panel and in the RPS Panel Communication Window to
2400 and you receive either an Invalid RPS Passcode or Retry count exceeded message,
reset the baud rate to 1200 in both RPS and the control panel.
Online Diagnostics Area Tab (D7212GV2/GV3 only). The Diagnostics Area Tab for the
D7212GV2 and GV3 accounts displays eight areas. The D7212GV2/GV3 control panels
only support four areas.
Master Armed Instant Status (Area Tab). RPS only displays the current status for Master
Armed Instant in the Area tab. RPS cannot send this command to the control panel.
Ground Fault Restoral Event. RPS does not show this event as a Ground Fault Restoral
event in the History List details. In the Events column, RPS shows Restoral Report. In
the Details column, RPS shows Area 1 Point N/A.
Routing Selections do not Match Diagnostic Reports Selections. To enable all Diagnostic
Reports or disable Diagnostic Reports for Route Groups 1 through 4, select Yes or No for
that category from PANEL-WIDE PARAMETERS > Routing. The only time you should
select specific reports from PANEL-WIDE PARAMETERS > Routing > Diagnostic Reports
is when you want to enable some diagnostic reports but not all. All Diagnostic Reports
selections made from that location appear as Custom in the corresponding Route
Group.
Panel Sync Window Appears When Control Panel and RPS are Synchronized (GV2 only).
The Panel Sync Window might appear even if the control panel account and RPS are
synchronized.
RPS Override of Control Panel High Security Features. For high security applications, the
control panel provides features such as Two-Man Rule and Early Ambush that require two
valid passcode entries to disarm an area. Disarming an area through the RPS Diagnostic
window overrides these high security features without alerting the RPS operator.
2014.05 | 34 | F01U045283
4.7
11
Alternate Communication Parameters for Computer Phone/IP Not Supported. RPS does
not support the three alternate communication parameters shown in Program Accounts >
Alternate Communications > Computer Phone/IP.
Zoom VFX 28.8 Modems. Zoom VFX 28.8 modems are not compatible with RPS and the
FPD-7024 FACP.
History Filter Might List Events in Wrong History Group. Events that appear in a History
Group list might not filter correctly for that group.
4.8
Select Modem Operation. When using Select Modem in Config > System > Modem, the
Apply to all Panel Groups option does not apply to the modem selection for an Easy
Series control panel. You must select the modem for an Easy Series control panel
separately from all other control panels.
No Point Numbers Shown for 24-Hour Trouble and Restoral Events. In RPS 5.10, the event
history for an Easy Series control panel account does not show the associated point
numbers for 24-Hour Trouble and 24-Hour Trouble Restoral events.
Incorrect Status in History for Failed and Pending Reports. If RPS retrieves history events
from an Easy Series control panel with firmware version 3.0 installed, the history log
shows an event report status of Failed when the actual status is Pending. The history log
also shows an event report status of Pending when the actual status is Failed.
DX4020 Firmware. If the DX4020 is used to provide a network connection between the
control panel and RPS, ensure the DX4020 is using firmware version 2.23 or later for
proper operation.
No User Number Shown for Key Fob Duress Events. RPS does not show in the History List
the user number for Duress events initiated from a wireless key fob. To identify the user
number, listen to the event in the control panel event history, or look at the event sent to
the central station receiver.
Cancel Events Show as Points instead of Users. In the History List, Cancel events show as
Keyfob Low Battery Acknowledge. This parameter is not supported by RPS. Setting this
2014.05 | 34 | F01U045283
12
en | Miscellaneous
Miscellaneous
Use the D9124default.dsf file on the RPS CD-ROM to create a D9124 account.
To create an account in RPS for either a D9412G or D7412G control panel, use either the
D9412 or D7412 control panel type.
5.1
5.1.1
Use the D7212G default.dsf file on the RPS CD-ROM to create a D7212G account.
To program a D2412 or D2812 control panel, use the D2212 control panel account.
2.
From the New Panel window, click the Existing tab. Select the v1.x control panel account
you wish to update to v2 from the list of existing panels, and click OK.
3.
You will convert this backup of the GV4 v1.x control panel account to a GV4 v2 control
panel account in the following steps. Fill in the appropriate fields and click OK.
5.1.2
In the Panel list window, highlight the backup GV4 v1.x control panel account you created
2.
In the control panel Data View window, click Edit, and then from the Panel Type
in the previous section, and then right-click the account and select View.
dropdown list, select the correct control panel type with [v2.00 or greater] (example,
D9412GV4 v2.00 or greater), and then click OK.
3.
Confirm the new, automatically changed configuration values match those needed for the
control panel. Make any necessary changes.
5.1.3
To import the new firmware into RPS, from the Main menu, select Config > System.
Select the Firmware Files tab, and then click Import.
2.
Click the Select Firmware File ellipsis (browse) buttons, and then browse to and select
3.
Click Open and then Next. When the import finishes, click Finish.
5.1.4
Open the original GV4 v1.x control panel account and connect to the control panel using
the Enhanced Direct, Network, IP Direct, or Cellular connection. Do not use a modem
connection.
2.
3.
Click Next, and then select the correct v2 firmware file. Click Next.
4.
Select the Acknowledge to Continue check box and click Next to begin the update. When
the update finishes, the Disconnecting from the Control Panel message appears.
5.1.5
5.
6.
Open the v2.00 control panel account you just created during the conversion process,
and click the Connect icon. The Panel Communication dialog box appears.
2.
Temporarily change the passcode in the RPS Passcode text box to 999999, and click
Connect. (On the next connection, you will not need to change the passcode to connect
to the panel (the accounts passcode is used.)
2014.05 | 34 | F01U045283
Miscellaneous | en
3.
4.
Select Send ALL Updated RPS Data to Panel and click OK. Note: Do not select Receive
13
Panel Data.
5.
6.
Be sure to perform a complete system test. A complete system test includes testing the
control panel, all devices, and communication paths for proper operation.
2014.05 | 34 | F01U045283