Titanium Udl-30 Brochure
Titanium Udl-30 Brochure
Titanium Udl-30 Brochure
INSTALLATION INSTRUCTIONS
Titanium UDL30 is an air, water and vapor barrier. It must be installed
above properly ventilated spaces (follow ALL building codes applicable to
your geographical regions and structure type) as it is considered a vapor
barrier (.06 perms). The use of a rosin paper slip-sheet is not required
underneath metal roofing systems. Protrusions from the deck area must be
removed and decks shall have no voids, damaged or unsupported areas.
The use of straight edge cutting knives is recommended. UDL30 is laid out
horizontally (parallel) to the eave with the printed side up, and using 4"
horizontal laps and 6" vertical laps. Follow building codes for low slopes as
defined as 2:12 to 4:12 and steep slopes greater than 4:12 applications.
FASTENERS: If leaving UDL30 exposed longer than 5 days product must
be attached to the structural roof deck material using a minimum
1"diameter plastic or metal caps with either ring shank nails (preferred) or
smooth leg nails (acceptable). Miami-Dade approved tin tags/metal caps
acceptable with the rough edge facing up. If product is going to be
covered with asphalt shingles or metal roofing panels within 5 days UDL30
can be installed with the use of corrosive resistant 3/8" head x 1" minimum
length leg roofing nail (ring shank nail leg is recommended).
DO NOT USE STAPLES: use of staples to penetrate UDL30 will void
warranty. Anchoring to be installed at a minimum as per surface markings
printed on the product, spaced 6" on center in the vertical and horizontal
laps, and at 12" along the center of the roll in the field. If underlayment will
be covered by primary roofing within 5 days of application, and not subject
to heavy traffic or high wind, then the option to use every other printed
anchoring point in the center field is acceptable.
All anchoring devices must be flush, 90 degrees to the roof deck, tight with
the underlayment surface and the structural roof deck. For extended
exposure (months) and or high wind, double the lap widths as a minimum.
Alternatively: Use a compatible sealant between the laps; use a peel and
stick tape between the laps; or fold the overlay laps forming a J channel
configuration before nailing.
For batten secured installations, use only adequate length ring shank nails
or screws (preferred), smooth leg nails (acceptable) to secure battens to
the structural roof deck material. The use of cap nails is only required to
secure UDL30 and prevent blow-off until the batten system is installed. Do
not install battens directly over any cap nails. If this occurs, remove cap nail,
patch the hole, then install cap outside batten field and continue.
Where seams and joints require sealant or adhesive, use a high quality, low
solvent asbestos free, plastic roofing cement meeting ASTM D-4586 Type
1 (Asbestos Free) Federal Spec SS-153 Type 1 (Asbestos Free) such as
Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are
butyl rubber, urethane, and EDPM based caulk or tape sealant. Depending
on roof pitch and surface conditions, blocking may be required to support
materials on the roof.
UDL30 is not designed for indefinite outdoor exposure. Final roofing
should be installed within 6 months.
MASSIVE
BILLBOARD!
FIBERGLASS
SHINGLES
FBC #1468
CLASS A
ASTM E108
ASTM D226
CAN/CSA A220.1
250 / 76.2 m
48 / 122 cm
40 lbs / 18.2 kg
10 sq / 93 m 2
30
1250 lbs / 567 kg
TITANIUM UDL30
TYPICAL VALUE
ASTM 30 LB FELT
TYPICAL VALUE
Pass
Pass
0.06 perms
Pass
MD 44 lbs (20 kg) CD 40 lbs (18 kg)
MD 143 lbs (65 kg) CD 110 lbs (50 kg)
250 psi (1720 kPa)
MD 18 % CD 18 %
4.0 lbs (1.82 kg)
25 mils (0.63 mm)
N/A
N/A
1.75 perms
Pass
MD 4 lbs (1.8 kg) | CD 2 lbs (0.9 kg)
MD 70 lbs (32 kg) | CD 38 lbs (17 kg)
62 psi (430 kPa)
MD 2% CD 2%
27.5 lbs ( 12.5 kgs)
60 mils (1.5 mm)
Test data is based on average taken over several production runs and should not be considered or interpreted as
minimum or maximum values. Values are typical data and not limiting specifications. All values 10 %
CONTRIBUTES TO
Titanium brand products are manufactured in accordance with national standards which allow for non-critical
variances in weights and measurements. 2014 InterWrap Inc. All rights reserved. * Recyclable where facilities exist.
UDL30_18Mar2014