5990 3953en
5990 3953en
5990 3953en
Option number
N9030A-503
N9030A-508
N9030A-513
N9030A-526
N9030A-543
N9030A-544
N9030A-550
Additional information
Option number
Additional information
N9030A-P03
N9030A-P08
N9030A-P13
N9030A-P26
N9030A-P43
N9030A-P44
N9030A-P50
Description
Option number
Additional information
Mechanical attenuator
Standard
N9030A-EA3
Description
Option number
Additional information
Standard
N9030A-B25
N9030A-B40
N9030A-B85
N9030A-B1X
N9030A-MPB
Option number
Standard
Additional information
Installed as N9030A-DP2
Standard
Installed as N9030A-EP1
Standard
LO/IM nulling
Standard
Standard
Improves displayed average noise level (DANL), second-generation algorithm (instrument alignment process); installed as N9030A-NF2
Standard
J7203A
N9030A-LNP
External mixing
N9030A-EXM
Provides external mixing with Keysight and third party mixers; single port 1 for
LO out and IF in (SMA female)
Fast power
N9030A-FP2
N9030A-C35
3.5 mm connector on 26.5 GHz PXA (Compatible with Option 526 only)
N9030A-BBA
Single-ended/differential, 50 /1 M impedance
(Compatible with Options 503, 508, 513, and 526)
Option number
N9030A-RT1
Additional information
Includes Frequency mask trigger; minimum 17.3 s signal duration for 100% probability of intercept (POI); requires N9030A-B85 or N9030A-B1X which determines the
maximum real-time BW
Real-time analysis up to
160 MHz BW, optimum detection
N9030A-RT2
Includes Frequency mask trigger; minimum 3.57 s signal duration for 100% probability of intercept (POI); requires N9030A-B1X or N9030A-B85 which determines the
maximum real-time BW
N9030A-RTR
Enables recording, analyzing and playback of spectrum density data over time for
detecting and analyzing signal anomalies; requires Option RT1 or RT2
Option number
N9030A-EMC
Additional information
Perform EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths: tune and listen, and measure at marker are also available
N9030A-EDP
N9030A-ESC
External source control for Keysight EXG, MXG, and PSG signal generators; supports
external mixing; includes 3 BNC cables and 1 crossover LAN cable
Option number
Standard
Additional information
Installed as N9030A-W7X
Option number
N9030A-SSD
Additional information
Provides a fully-imaged, removable SSD in addition to the one installed in instruments
N9020A-SF1
N9020A-SF2
1. When used with the Keysight 11970 Series external mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as
N9029AE13, or from OML Inc. as DPL313B.
Option number
Additional information
Second IF output
N9030A-CR3
Arbitrary IF out
Y-axis video out
Aux log video out
Real-time link
N9030A-CRP
N9030A-YAV
N9030A-ALV
Standard
Transportable
license
N9080B-1FP
N9080B-1TP
N9080B-2FP
N9080B-2TP
N9082B-1FP
N9082B-1TP
N9082B-2FP
N9082B-2TP
N9083A-1FP
N9083A-1TP
W-CDMA/HSPA+
N9073A-1FP
N9073A-1TP
N9073A-2FP
N9073A-2TP
Description
Additional information
Cellular communications
LTE/LTE-Advanced FDD
LTE/LTE-Advanced TDD
N9073A-3FP
N9073A-3TP
GSM/EDGE/EVO
N9071A-2FP
N9071A-2TP
N9071A-3FP
N9071A-3TP
TD-SCDMA/HSPA
N9079A-1FP
N9079A-1TP
N9079A-2FP
N9079A-2TP
1xEV-DO
N9076A-1FP
N9076A-1TP
cdma2000/cdmaOne
N9072A-2FP
N9072A-2TP
iDEN/WiDEN/MotoTalk
N6149A-2FP
N6149A-2TP
Mobile WiMAX
N9075A-2FP
N9075A-2TP
WLAN 802.11a/b/g/n/ac
N9077A-2FP
N9077A-2TP
N9077A-3FP
N9077A-3TP
Wireless connectivity
Bluetooth
N9077A-4FP
N9077A-4TP
N9081A-2FP
N9081A-2TP
Standard-based, one-button Bluetooth version 2.1+ EDR and Low Energy (LE)
measurements
Step 11. Choose measurement application or software and license type, continued
Fixed license
Transportable
license
CMMB
N6158A-2FP
N6158A-2TP
Digital cable TV
N6152A-2FP
N6152A-2TP
N6152A-3FP
N6152A-3TP
DTMB (CTTB)
N6156A-2FP
N6156A-2TP
DVB-T/H/T2
N6153A-2FP
N6153A-2TP
N6153A-3FP
N6153A-3TP
N6155A-2FP
N6155A-2TP
N6155A-3FP
N6155A-3TP
Spectrum analyzer
Standard
Not available
Traditional spectrum analysis plus many new and enhanced functions; power measurements based on industry speciications; installed as N9060B
Analog demodulation
N9063A-2FP
N9063A-2TP
N9063A-3FP
N9063A-3TP
Phase noise
N9068A-2FP
N9068A-2TP
Noise igure
N9069A-1FP
(requires
preampliier)
N9069A-1TP
(requires
preampliier)
Adds one-button measurements for noise igure, gain, and related metrics;
requires preampliier to meet speciications; works with Keysight N400xA Series
smart noise sources and 346 Series noise sources; supports U7227 USB external
preampliiers
N9069A-2FP
N9069A-2TP
N9064A-1FP
N9064A-1TP
N9064A-2FP
N9064A-2TP
Adds lexible digital modulation analysis; general purpose digital modulation for
2-16FSK, 2-8PSK, and 16-1024QAM, as well as more than 15 additional formats;
requires 1FP/1TP
N6141A-2FP
N6141A-2TP
N6171A-M01
Not available
Basic signal analysis package; adds MATLAB software environment and the Instrument Control Toolbox (not upgradeable)
N6171A-M02
Not available
Standard signal analysis package; includes basic package and adds Communications Toolbox and Signal Processing Toolbox (not upgradeable)
N6171A-M03
Not available
Advanced signal analysis package; includes standard package and adds Filter
Design Toolbox, RF Toolbox, and System Test (not upgradeable)
Description
Additional information
Digital video
ISDB-T/Tmm
General purpose
EMC
MATLAB software
Step 11. Choose measurement application or software and license type, continued
Fixed license
Transportable
license
N9051A-2FP
Not available
Automates pulse measurements; combines signal analysis and amplitude vs. time
measurements
N9051A-3FP
Not available
N9051A-4FP
Not available
N9062A-2FP
Not available
Remote language
compatibility
N9061A-1FP
Not available
N9061A-2FP
Not available
Not available
89601B
(transportable
license is
standard)
Description
Option number
Additional information
Standard
Standard
Standard
Standard
Standard
Standard
Standard
N9030A-1CM
N9030A-1CN
N9030A-1CP
N9030A-1CR
N9030A-DVR
N9030A-KB2
N9030A-MLP
M1970V-001
M1970V-002
M1970E
M1970W
11970A
11970Q
11970U
11970V
11970W
N9029AE13
N9029AE08
N9029AE06
Description
Additional information
Option number
Additional information
N9029AE05
N9029AE03
N9029AV15
N9029AV12
N9029AV10
N9029AV08
N9029AV06
N9029AV05
N9029AV03
N9029AV02
N9029AV1B
N9029AV01
N5262VDI-175
J7203A
U7227A
U7227C
U7227F
Option number
N9030A-AB1
N9030A-AB2
N9030A-ABD
N9030A-ABF
N9030A-ABJ
N9030A-AKT
Option number
Additional information
Standard
R-51B-001-5C
Step 15. Add calibration, technical training, support, and upgrade services
Description
Option number
Additional information
N9030A-UK6
N9030A-AMG
N9030A-A6J
R-50C-011-3
Instrument Upgrades
Fast license-key upgrades for performance options that do not require
additional hardware:
1. Place an order for the upgrade with Keysight and request to receive the
option upgrade entitlement certiicate and a one-time software upgrade
license through email
2. Redeem the certiicate through the Web by following the instructions on
the certiicate
3. Install the license ile and latest software in the PXA
4. Begin using the new capability 1, 2 Installation and testing information is
available at: www.keysight.com/ind/pxa_upgrades
Upgrades for analysis bandwidth depend on the vintage of the instrument and
the options already installed. More than one option may be required to achieve
desired wider analysis bandwidth. Use our web-based calculator to ind the
upgrade options you may need: www.keysight.com/ind/BW-selector
UP
GRADE
Description
Upgrade number
N9030AK-F01
N9030AK-F02
503
N9030AK-F03
503
N9030AK-F04
503
N9030AK-F05
503
N9030AK-F06
508
N9030AK-F07
508
N9030AK-F08
508
N9030AK-F09
508
N9030AK-F10
513
N9030AK-F11
513
N9030AK-F12
513
N9030AK-F13
526
N9030AK-F14
526
N9030AK-F15
543/544
1.
Additional information
At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was veriied to be within its warranted speciications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or veriication
testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its irst year, or if the analyzer is more than one year old, additional adjustment and
performance veriication tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests
does not guarantee that the analyzer meets all warranted speciications.
Description
Upgrade number
N9030AK-B25
Real-time analysis up to
160 MHz BW, optimum detection
N9030AK-B40
N9030AK-BU1
N9030AK-HLB
N9030AK-BU2
N9030AK-B85
N9030AK-B1X
N9030AK-BU5
N9030AK-BU3
N9030AK-RT1
N9030AK-RT2
N9030AK-EA3
None
N9030AK-P03
N9030AK-P08
N9030AK-P13
N9030AK-P26
Additional information
Also enables 25 MHz per channel baseband bandwidth if
Option BBA is installed
Also enables 40 MHz per channel baseband bandwidth if
Option BBA is installed
Also enables 40 MHz per channel baseband bandwidth if
Option BBA is installed
Includes additional hardware
Includes additional hardware
Includes additional hardware
Includes additional hardware
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was
veriied to be within its warranted speciications. Within one year of the initial calibration date of the analyzer, this option is fully
calibrated with no further adjustment or veriication testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its irst year, or if the analyzer is more than one year old,
additional adjustment and performance veriication tests are required to ensure that some newly installed options are functioning
properly. However, the completion of these tests does not guarantee that the analyzer meets all warranted speciications.
Description
Upgrade number
N9030AK-P43
543
N9030AK-P44
544
N9030AK-P50
550
N9030AK-C35
526
N9030AK-BBA
Additional information
N9094AK-W7X
N9094AK-PC4
(Under the N9030AK)
PC2
N9094AK-W7X
N9094AK-SSD
(Under the N9030AK)
PC4
Upgrade to dual core 64-bit performance processor, 8 GB RAM, removable solid-state drive
N9094AK-W7X
N9094AK-PC4
(Under the N9030AK)
PC2
N9094AK-W7X
N9094AK-SSD
(Under the N9030AK)
PC4
N9094AK-WXP
N9094AK-SSD
(Under the N9030AK)
None
N9030AK-EXM
N9030AK-HL6
N9030AK-CR3
None
N9030AK-MPB
LNP or B1X
N9030AK-LNP
MPB or B1X
N9030AK-HL1
N9030AK-HL2
N9030AK-YAV
None
Arbitrary IF output
N9030AK-CRP
None
N9030AK-ALV
None
N9030AK-FP2
Description
Upgrade number
N9030AK-EMC
None
N9030AK-EDP
None
N9030AK-ESC
None
None
None
N9030AK-DVR
None
N9030AK-KYB
None
N9030AK-KB2
None
N9030AK-1CP
None
N9030AK-1CR
None
N9030AK-1CN
None
N9030AK-1CM
None
N9030AK-MLP
None
N9030AK-CVR
None
N9030AK-AB1
None
N9030AK-AB2
None
N9030AK-ABD
None
N9030AK-ABF
None
N9030AK-ABJ
None
N9030AK-AKT
None
Additional information
Compliant with CISPR 16-1-1 2007 detectors and
BWs
Related Literature
Keysight PXA signal analyzers
Publication title
Publication number
Brochure
5990-3951EN
Data Sheet
5990-3952EN
5990-8019EN
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysights commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysights measurement expertise and product
breadth, combined with channel partner convenience.
Asia Paciic
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
www.keysight.com/find/pxa
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
0800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637