Synchronous Generator MCQ 1 147
Synchronous Generator MCQ 1 147
Synchronous Generator MCQ 1 147
Ads by Google
AC Synchronous Motor
Turbine Generator
Motor Generator
Ads by Google
Be Generato
Alternators
DC Generato
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (46-60)
1 of 3
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
51. In the above figure which curve represents open circuit voltage ?
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
52. For a peripheral speed of 314 m/s, a 2 pole cylindrical machine will
have maximum diameter of
(A) 255 cm
(B) 235 cm
(C) 200 cm
(D) 170 cm.
Get Answer: (Show)
53. The rotor of the salient pole alternator has 24 poles. The number of
cycles of emf in one revolution would be
(A) 24
(B) 12
(C) 6
(D) 4.
Get Answer: (Show)
54. Two alternators A and B are sharing an inductive load equally. If the
excitation of alternator A is increased
(A) alternator B will deliver more current and alternator A will deliver less
current
(B) alternator B will deliver less current and alternator A will deliver more
current
(C) both will continue to share load equally
(D) both will deliver more current.
Get Answer: (Show)
55. Desirable feature for the parallel operation of two alternators is
(A) both should have same resistance
(B) both should have same reactance
(C) both should have less of resistance as compared to synchronous
reactance
(D) both should have more of resistance as compared to synchronous
reactance.
Get Answer: (Show)
56. Alternators used in aircraft systems usually have frequency of
(A) 25 Hz
(B) 50 Hz
(C) 100 Hz
(D) 400 Hz.
Get Answer: (Show)
57. High frequency on aircraft alternators is selected in order to
(A) free the systems from external disturbance
(B) compensate for high speeds
(C) compensate for high altitudes
(D) reduce the bulk.
Get Answer: (Show)
58. A 20 pole ac generator rotates at 600 rpm. The periodic time of current
in seconds per cycle is
(A) 0.009
(B) 0.004
(C) 0.008
(D) 0.01.
Get Answer: (Show)
59. What kind of rotor is most suitable for turbo alternators ?
(A) salient pole type
(B) non-salient pole type
(C) both (A) and (B) above
(D) none of the above.
Get Answer: (Show)
60. The synchronizing power developed in one of the alternators, when two
alternators are running in parallel, will load the same alternator in which it is
developed and reduce its speed
(A) True
Synchronous Generator : Multiple Choice Questions (46-60)
2 of 3
(B) False
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
About Us | Privacy Policy | Contact Us | Resources | Link to Us
Copyright 2010,ElectricalQuizzes. All rights reserved.
Synchronous Generator : Multiple Choice Questions (46-60)
3 of 3 4/4/2013 3:51 PM
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (61-75):
61. If the input to the prime mover of an alternator is kept constant but the
excitation is changed then the
(A) reactive component of the output is changed
(B) active component of the output is changed
(C) power factor of load remains constant.
Get Answer: (Show)
62. If two machines are running in synchronism and the voltage of one
machine is suddenly increased
(A) the machines will burn
(B) both machines will stop
(C) synchronising torque will be produced to restore further synchronism.
Get Answer: (Show)
63. In an alternator, at 0.8 lagging power factor, the generated voltage per
phase is 240 V to give a rated terminated voltage ' V '. If the power factor of
load increases to unity, the generated voltage per phase must be
(A) 260 V
(B) 250 V
(C) 240 V
(D) 225 V.
Get Answer: (Show)
64. The advantage of salient poles in an alternator is
(A) reduce noise
(B) reduced windage loss
(C) adoptability to low and medium speed operation
(D) reduce bearing loads and noise.
Get Answer: (Show)
65. Magnetisation curves for no load and full load unity power factor are
shown in figure below. Which is the magnetisation curve for full load 0.8
power factor ?
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
66. At a particular instant a turbo alternator is generating 80 MW at 0.8
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
Rotomoulding Machine
www.naroto.com
NAROTO Leading Manufacturer and Exporter of Rotational Moulding M/c
Ads by Google Generator 3 Phase Generator Synchronous Motor Electric Motor
Ads by Google
AC Synchronous Motor
Electric Power Generato
Generator Load Banks
Ads by Google
DC Motor
Power Factor
Electrical
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (61-75)
1 of 3
power factor lagging. Now if the steam supply valve to the steam turbine is
further opened and the excitation is not changed
(A) the speed of the alternator will increase but kW delivered will remain
unchanged
(B) the speed of the alternator will increase and kW delivered will also
increase
(C) the speed of the alternator will remain unchanged but it can meet more
kW demand
(D) the speed of the alternator will remain unchanged but it will deliver more
kVA.
Get Answer: (Show)
67. Two alternators A and B are sharing a resistive load (p.f. = 1 ) equally.
Now if the excitation of alternator A is increased
(A) alternator A will become lagging and alternator B will become leading
(B) alternator A will become leading and alternator B will become lagging
(C) both alternators will continue to operate on unity power factor
(D) both alternators will operate on lagging power factor
(E) both alternators will operate on leading power factor.
Get Answer: (Show)
68. The advantage of providing damper winding in alternators is
(A) elimination of harmonic effects
(B) provide a low resistance path for the currents due to unbalancing of
voltage
(C) oscillations are provided when two alternators operate in parallel
(D) all of the above.
Get Answer: (Show)
69. When two alternators are running in exactly synchronism, the
synchronising power wil be
(A) zero
(B) sum of the output of two
(C) unity
(D) 0.707.
Get Answer: (Show)
Questions 70 to 72 refer to the figure given below :
70. Load characteristic curves for an alternator are shown. The curves are
drawn for 0.8 pf lagging, 0.8 p.f. leading, 0.7 p.f. leading and 0.9 p.f.
lagging. Which curve represents the characteristics for 0.8 p.f. leading ?
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
71. Which curve represents the data for 0.8 p.f. lagging ?
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
72. Which curve represents the data for 0.9 p.f. lagging ?
(A) curve A
(B) curve B
(C) curve C
(D) curve D.
Get Answer: (Show)
73. The balanced short circuit current of a three phase alternator is 25
amperes at 1500 rpm. For the same field current, the balanced short
current at 1400 rpm will be
(A)18 A
(B) 27 A
(C) 20 A
(D) 20*(2)
1/2
A
Synchronous Generator : Multiple Choice Questions (61-75)
2 of 3
Get Answer: (Show)
74. A three phase alternator has a phase sequence of RYB for its three
output voltages, for clockwise rotation. Now if the alternator is rotated
anticlockwise, the phase sequence will be
(A) RYB
(B) RBY
(C) BYR
(D) none of the above.
Get Answer: (Show)
75. In a synchronous machine, if the field flux axis is ahead of the armature
field axis, in the direction of rotation, the machine working as
(A) asynchronous motor
(B) asynchronous generator
(C) synchronous motor
(D) synchronous generator.
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
About Us | Privacy Policy | Contact Us | Resources | Link to Us
Copyright 2010,ElectricalQuizzes. All rights reserved.
Synchronous Generator : Multiple Choice Questions (61-75)
3 of 3 4/4/2013 3:55 PM
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (76-90):
76. In synchronous alternator, which of the following coils will have emf
closer to sine waveform ?
(A) concentrated winding in full pitch coils
(B) concentrated winding in short pitch coils
(C) distributed winding in full pitch coils
(D) distributed winding in short pitch coils.
Get Answer: (Show)
77. An alternator has rated field current of 4 A. The alternator develops 180
V while drawing a field current of 2 A at 750 rpm. If the field current is made
4 A at 750 rpm generated voltage could be
(A) 400 V
(B) 380 V
(C) 60V
(D) 330 V.
Get Answer: (Show)
78. The armature reaction of an alternator will be completely magnetizing in
case the load power factor is
(A) unity
(B) 0.707
(C) zero lagging
(D) zero loading.
Get Answer: (Show)
79. Which of the following is not an integral part of synchronous generator
system ?
(A) prime mover
(B) distribution transformer
(C) excitation system
(D) protection system.
Get Answer: (Show)
80. For turbo generators the range of excitation voltage is
(A) 10 to 20 V
(B) 30 to 100 V
(C) 100 to 800 V
(D) 1000 to 1800 V.
Get Answer: (Show)
81. In case of low speed hydrogenerators, the short circuit ratio is usually
(A) 0.1 to 0.5
(B) 0.5 to 0.6
(C) 0.6 to 1.0
(D) 1.0 to 1.5.
Get Answer: (Show)
82. The permissible duration for which a generator of rated frequency 50
Hz can run at 46 Hz is
(A) zero
(B) one cycle
(C) one second
(D) one minute.
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
Rotomoulding Machine
www.naroto.com
NAROTO Leading Manufacturer and Exporter of Rotational Moulding M/c
Ads by Google Wind Generator Power Generator Motor Generator Turbine Generator
Ads by Google
Inverter Generator
Turbine Generator
Windkraft Generator
Ads by Google
Be Generato
DC Generato
DC Motor
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (76-90)
1 of 3
Get Answer: (Show)
83. The permissible duration in supply . frequency is
(A) 2 %
(B) 5 %
(C) 10 %
(D) 25 %.
Get Answer: (Show)
84. The regulation of an alternator is likely to be negative in case of
(A) high speed alternators
(B) slow speed alternators
(C) lagging power factor of the load
(D) leading power factor of the load.
Get Answer: (Show)
Questions 85 to 88 refer to the data given below:
A phase, 50 Hz, 6600 V, alternator is rated at 6600 kW at 0.8 power factor
and a full load efficiency of 90%.
85. kVA is rating of the alternator is
(A) 750 kVA
(B) 7500 kVA
(C) 75000 kVA
(D) 750000 kVA.
Get Answer: (Show)
86. The current rating of the alternator is
(A) 65.63 A
(B) 656.3 A
(C) 6563 A
(D) 65630 A.
Get Answer: (Show)
87. The input to the alternator is
(A) 666.6 kW
(B) 6666 kW
(C) 66660 kW
(D) 666,600 kW.
Get Answer: (Show)
88. If the input. to an alternator remains unaltered, but excitation is changed
then which of the following will not change ?
(A) kVA output
(B) kW output
(C) power factor
(D) all of the above.
Get Answer: (Show)
89. Which of the following method is likely to give the voltage regulation
more than the actual value ?
(A) Synchronous reactance method
(B) MMF method
(C) Zero power factor method
(D) None of the above.
Get Answer: (Show)
90. The effect of cross magnetization in an alternator field is to make the
output
(A) true sinusoidal
(B) non-sinusoidal
(C) harmonic free
(D) none of the above.
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator : Multiple Choice Questions (76-90)
2 of 3
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (91-105):
91. In order to reduce the harmonics in the emf generated in an alternator
(A) slots are skewed
(B) salient pole tips are chamfered
(C) winding is well distributed
(D) all of the above.
Get Answer: (Show)
92. The maximum power in a synchronous machine is obtained when the
load angle is
(A) 0
(B) 85
(C) 120
(D) 135.
Get Answer: (Show)
93. The emf generated due to nth harmonic component of flux in an
alternator will be
(A) n times the fundamental emf
(B) same as fundamental emf
(C) less than the value of fundamental emf.
Get Answer: (Show)
94. Synchronizing torque comes into operation under all of the following
cases EXCEPT
(A) phase difference between two voltages
(B) frequency difference between two voltages
(C) voltage difference between two voltages
(D) reduction in exciting current in one of the alternators.
Get Answer: (Show)
95. Unbalanced 3-phase stator currents cause
(A) double frequency currents in the rotor
(B) healing of rotor
(C) vibrations
(D) all of the above.
Get Answer: (Show)
96. In large generators protection provided against external faults is
(A) biased differential protection
(B) sensitive earth fault protection
(C) inter-turn fault protection
(D) all of the above.
Get Answer: (Show)
97. Pitch factor is the ratio of the emfs of
(A) short pitch coil to full pitch coil
(B) full pitch winding to concentrated winding
(C) full pitch winding to short pitch winding
(D) distributed winding to full pitch winding.
Get Answer: (Show)
98. In an alternator if the winding is short pitched by 50 electrical degrees,
its pitch factor will be
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
Rotomoulding Machine
www.naroto.com
NAROTO Leading Manufacturer and Exporter of Rotational Moulding M/c
Ads by Google Wind Generator Used Generator Power Generator 3 Phase Generator
Ads by Google
3 Phase Generator
Turbine Generator
Windkraft Generator
Ads by Google
Be Generato
DC Generato
Stator Coils
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (91-105)
1 of 3
(A) 1.0
(B) 0.866
(C) 0.75
(D) 0.50.
Get Answer: (Show)
99. The Potier's triangle separates
(A) stator losses and rotor losses
(B) fixed losses and variable losses
(C) armature voltage and field voltage
(D) armature leakage reactance and armature reaction mmf.
Get Answer: (Show)
100. If a single phase alternator has 8 slots per pole uniformly speed, but
the winding is arranged with the middle two left empty, the breadth
coefficient will be
(A) 0.99
(B) 0.88
(C) 0.67
(D) 0.53.
Get Answer: (Show)
101. Two alternators are running in parallel. If the field of one of the
alternator is adjusted, it will
(A) reduce its speed
(B) change its load
(C) change its power factor
(D) change its frequency.
Get Answer: (Show)
102. A generator is operating by itself supplying the system loads. The
reactive power supplied by the generator will
(A) depend on prime mover rpm
(B) depend on type of insulation used
(C) depend on the amount demanded by the load
(D) depend on inter-coil inductance.
Get Answer: (Show)
103. Which of the following part plays important role in over speed
protection of a generator ?
(A) Over current relay
(B) Alarm
(C) Differential protection
(D) Governor.
Get Answer: (Show)
104. Which type of protection is provided on a generator to protect against
stator insulation failure ?
(A) Differential protection
(B) Thermocouple actuated alarm
(C) Over current relay
(D) Reverse power relay.
Get Answer: (Show)
105. Which relays comes into operation in the event of the failure of prime
mover connected to ihe generator ?
(A) Reverse power relay
(B) Differential relay
(C) Buchholz relay
(D) None of the above.
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
About Us | Privacy Policy | Contact Us | Resources | Link to Us
Synchronous Generator : Multiple Choice Questions (91-105)
2 of 3
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (106-120):
106. In alternators, the distribution factor is defined as the ratio of emfs of
(A) distributed winding to connected winding
(B) full pitch winding to distributed winding
(C) distributed winding to full pitch winding
(D) concentrated winding to distributed winding.
Get Answer: (Show)
107. One of the advantages of distributing the winding in alternator is to
(A) reduce noise
(B) save on copper
(C) improve voltage waveform
(D) reduce harmonics.
Get Answer: (Show)
108. In case of a uniformly distributed winding, the value of distribution
factor is
(A) 0.995
(B) 0.80
(C) 0.75
(D) 0.50.
Get Answer: (Show)
109. The advantage of a short pitch winding is
(A) low noise
(B) increased inductance
(C) suppression of harmonics
(D) reduced eddy currents.
Get Answer: (Show)
110. Two alternators are connected in parallel. Their kVA and kW load
share can be changed by changing respectively their
(A) driving torque and excitation
(B) excitation and driving torque
(C) excitations only
(D) driving torques only.
Get Answer: (Show)
111. In case of alternators, the dark and bright lamp method is used for
(A) phase sequence
(B) load balancing
(C) synchronizing
(D) load transfer.
Get Answer: (Show)
112. The advantage of using short pitched windings in an alternator is that
it
(A) suppresses the harmonics in generated emf
(B) reduces the total voltage around the armature coils
(C) saves copper used in windings
(D) improves cooling by better circulation of air.
Get Answer: (Show)
113. For the same power rating, an alternator operating at lower voltage will
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
Maintenance Free Earthing
www.ennovearthing.com
ENNOV - Safe Gel Chemical Earthing, For Best Rates Call Now 09818666056
Ads by Google Wind Generator Used Generator Power Generator Turbine Generator
Ads by Google
Windpower Generator
Turbine Generator
Motor Generator
Ads by Google
Be Generato
DC Generato
DC Motor
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (106-120)
1 of 3
be
(A) less noisy
(B) costlier
(C) larger in size
(D) more efficient.
Get Answer: (Show)
114. Which of the following is the common synchronous speed in rpm
between 60 Hz and 50 Hz alternators ?
(A) 900
(B) 600
(C) 375
(D) 225.
Get Answer: (Show)
115. All of the following losses for a synchronous machine are fixed
EXCEPT
(A) Bearing friction loss
(B) Copper loss
(C) Windage loss
(D) Core loss.
Get Answer: (Show)
116. Salient pole type rotors as compared to cylindrical pole type are
(A) smaller in diameter and larger in axial length
(B) larger in diameter and smaller in axial length
(C) larger in diameter as well as axial length
(D) small in diameter as well as axial length.
Get Answer: (Show)
117. In a synchronous machine, the field flux axis is ahead of the armature
field axis in the direction of rotation, the machine is working as
(A) asynchronous alternator
(B) asynchronous motor
(C) synchronous motor
(D) synchronous alternator.
Get Answer: (Show)
118. Which of the following is not a common synchronous speed in rpm
between a 50 Hz and 25 Hz alternator ?
(A) 750
(B) 375
(C) 250
(D) 200.
Get Answer: (Show)
119. The effective voltage in one phase of an alternator having 240 turns
per phase, frequency of 60 Hz and flux per pole of 2.08 x 10
6
lines will be
(A) 332.5 V
(B) 665 V
(C) 1330 V
(D) 2660 V.
Get Answer: (Show)
120. The maximum current that can be supplied by an alternator depends
on
(A) speed of the exciter
(B) number of poles
(C) exciter current
(D) strength of the magnetic field.
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
About Us | Privacy Policy | Contact Us | Resources | Link to Us
Synchronous Generator : Multiple Choice Questions (106-120)
2 of 3
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (121-135):
121. The windings for an alternator are
I. 36 slots, four poles, span 1 to 8
II. 72 slots, six poles, span 1 to 10
III. 96 slots, six poles, span 1 to 12.
The windings having pitch factors of more than 0.9 are
(A) I and II only
(B) II and III only
(C) I and II only
(D) I, II and III.
Get Answer: (Show)
Questions 122 to 124 refer to data given below:
A 500 kVA ,2300 volt three phase star connected alternator has a full load
armature-resistance drop per phase of 50 volts and a combined armature
reactance plus armature-reaction drop of 500 volts per phase
122. The percent regulation of the alternator at unity power factor is
(A) 1.05
(B) 10.5
(C) 21.5
(D) 27.5.
Get Answer: (Show)
123. The percent regulation of the alternator at 0.866 power factor lagging
is
(A) 26.3
(B) 20.1
(C) 16.6
(D) 10.5.
Get Answer: (Show)
124. The percent regulation of the alternator at 0.8 power factor leading is
(A) 13.2
(B) 26.4
(C) - 26.4
(D) - 13.2.
Get Answer: (Show)
125. The imaginary or fictitious part of synchronous reactance takes care of
(A) armature reaction
(B) voltage regulation
(C) inductive reactance
(D) none of the above.
Get Answer: (Show)
126. In an alternator, the use of short pitch coils of 160 will indicate the
absence of
(A) third harmonic
(B) fifth harmonic
(C) seventh harmonic
(D) ninth harmonic.
Get Answer: (Show)
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
Forex Money
www.iFOREX.in
This Year Made Traders 100s% Profit Get Free Training Pack To Learn How
Ads by Google Wind Generator Power Generator Turbine Generator Motor Generator
Ads by Google
Turbine Generator
Motor Generator
Windkraft Generator
Ads by Google
Be Generato
DC Generato
DC Motor
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (121-135)
1 of 3
127. When a generator designed for operation at 60 Hz is operated at 50
Hz
(A) operating voltage must be derated to (50/60) of its original value
(B) operating voltage must be derated to (50/60)
2
of its original value
(C) kVA rating can be upgraded to (60/50) of the rated value
(D) the generator will not take any load.
Get Answer: (Show)
128. Overheating of generator's winding
(A) reduces generated voltage
(B) reduces power factor
(C) reduces life of the machine
(D) does not have any significant effect.
Get Answer: (Show)
129. Rotor shaft of 500 MW alternator is supported in
(A) ball bearings
(B) roller bearings
(C) needle bearings
(D) journal bearings.
Get Answer: (Show)
130. The voltage of field system for an alternator is usually
(A) less than 200 V
(B) between 200 V and 440 V
(C) 400 V
(D) more than 1 kV.
Get Answer: (Show)
131. Maximum electric power output of a synchronous generator is
(A) Xs / VtEf
(B) V
2
t / Xs
(C) E
2
f / Xs
(D) VtEf / Xs
Get Answer: (Show)
132. The electrical angle between the field axis and axis of armature
reaction of a loaded synchronous generator with armature current lagging
behind the excitation emf by is
(A) - 90
(B) + 90
(C) 90 -
(D) + 180.
Get Answer: (Show)
133. Two synchronous generators G1and G2 are equally sharing the KVAR
of the load while operating in parallel. Keeping the terminal voltage fixed in
order to shift part of the KVAR load from G2 to G1
(A) The field current of G1 is lowered
(B) The field current of G2 is raised
(C) The field current of G1 is raised and of G2 lowered
(D) The field current of G1 is lowered and of G2 is raised.
Get Answer: (Show)
134. A synchronous generator is operating with excitation adjusted for unity
power factor current at constant load. When on increasing the excitation
the power factor
(A) will lag
(B) will lead
(C) will become zero
(D) none of the above.
Get Answer: (Show)
135. On changing the speed of an alternator from 4000 rpm to 2000 rpm,
the generated emf phase will become
(A) 1/4
(B) 1/2
(C)1/3
(D)1/5
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >>Next MCQ's Page
Synchronous
Generator Theory
Page1
Page2
Page3
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator : Multiple Choice Questions (121-135)
2 of 3
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
Electric Circuit and Ohm's Law
Synchronous Generator
Synchronous Motors
Single Phase Motors
Electric Power Generation
Power Generation Economics
Transmission and Distribution
Circuit Breakers
High Voltag Engineering
Rectifiers and Converters
Electric Illumination
Electric Traction
Electric Machine Design
Industrial Drives
Computation
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Synchronous Generator
Multiple Choice Questions of Synchronous Generator (136-147):
136. Zero power factor method of an alternator is used to find its
(A) field resistance
(B) armature resistance
(B) armature resistance
(C) efficiency
(D) voltage regulation.
Get Answer: (Show)
137. The power factor of an alternator is obtained from its
(A) excitation
(B) speed
(C) load
(D) none of the above.
Get Answer: (Show)
138. For parallel operation, alternators must have
(A) same speed
(B) same kVA rating
(C) same voltage rating
(D) none of the above.
Get Answer: (Show)
139. For alternation having fractional pitch of 5/6 the coil span is
(A)90
(B)120
(C)150
(D)180
Get Answer: (Show)
140. Fractional pitch to eliminate 7th harmonic from alternator emf is
(A) 7/6
(B) 6/7
(C) 6/5
(D) 3/5.
Get Answer: (Show)
141. Consider the following statements about a three-phase synchronous
generator synchronized to an infinite bus when its mechanical input is
increased gradually with field current held constant:
1. The power factor of the current supplied becomes more lagging.
2. The power factor of the current supplied improves.
3. The power factor remains unity.
4. The load angle is increased.
Of these statements
(A) 1 alone is correct
(B) 2 alone is correct
(C) 2 and 4 are correct
(D) 3 and 4 are correct.
Get Answer: (Show)
142. A 3-phase synchronous generator, with its armature resistance and
the leakage reactance being neglected, is synchronized to an infinite bus
and its field excitation is kept constant thereafter. Now the machine is
loaded by Supplying mechanical input to the shaft so that the load-angle
Search
Test Your
Electrical
Concepts !
Solve papers
and get your
results.
Coming Soon!
HDFC Bank Official Site
www.hdfcbank.com
Offers a Wide Range of Banking Services with Fast Processing.
Ads by Google Wind Generator Used Generator Power Generator Motor Generator
Motor Controller
Tutorial
www.GaliLmc.com
Free Web Tutorials from
Galil, the World Leader in
Motor Controllers.
Brand New
Classifieds
allthingsdiesel.co.za
Calling all Buyers and Sellers
of All Things Diesel - Free
ads placed
Ads by Google
Motor Generator
Turbine Generator
Windkraft Generator
Ads by Google
Be Generato
DC Generato
DC Motor
Electrical Quizzes
Like
2,379 people like Electrical Quizzes.
Facebook social plugin
Synchronous Generator : Multiple Choice Questions (136-147)
1 of 2
reaches a value of 60 Under this condition, the operating power-factor
would be
(A) 0.866 leading
(B) 0.866 lagging
(C) 0.5 leading
(D) 0.5 lagging.
Get Answer: (Show)
143. A round rotor synchronous generator has a leakage reactance of 10%,
armature reaction reactance of 90% and negligible armature resistance.
With the machine initially running at rated speed and terminal voltage of 1.0
p.u., a 3-phase short-circuit is applied. The sustained armature current will
be
(A) 1.25 p.u.
(B) 1.11 p.u.
(C) 1.0 p.u.
(D) 0.9 p.u.
Get Answer: (Show)
144. Following a sudden short-circuit at the terminals of a 3-phase
unloaded synchronous generator, the initial effect of the pole-face damper
windings, is to
(A) establish the armature flux through the direct-axis magnetic circuit of the
machine
(B) allow only partial linkage of the armature flux with the main field winding
(C) confine the armature flux to completely link the damper winding
(D) repel the armature flux and confine it to the leakage flux path in the
air-gap.
Get Answer: (Show)
145. In a synchronous generator operating at zero pf lagging, the effect of
armature reaction is
(A) magnetizing
(B) demagnetizing
(C) cross-magnetizing
(D) both magnetizing and cross-magnetizing.
Get Answer: (Show)
146. Which of the following limit the reactive power output of a synchronous
generator ?
1. Armature current
2. Field current
3. Load angle
4. Prime mover input.
Select the correct answer using the codes given below:
Codes
(A) land 2
(B) 2 and 3
(C) 3 and 4
(D) land 4.
Get Answer: (Show)
147. The steady-state stability limit of a synchronous generator can be
increased by
(A) an increase in its reactance
(B) an increase in the excitation of the machine
(C) a decrease in the moment of inertia of the machine
(D) an increase in the moment of intertia of the machine.
Get Answer: (Show)
Get all answers at once: (Show)
<<Previous MCQ's Page >> True / False Questions
Synchronous
Generator Theory
Page1
Page2
Page3
Page4
Synchronous
Generator MCQ's
01-15 16-30 31-45
46-60 61-75 76-90
091-105 106-120
121-135 136-147
Synchronous
Generator True /
False
Page1 Page2
Synchronous
Generator Fill in the
blanks
Fill in theblanks 1
Fill in theblanks 2
Home Electrical Theory Electrical MCQ's Electrical True / False Questions Fill in the Blank Questions Contact Us
About Us | Privacy Policy | Contact Us | Resources | Link to Us
Copyright 2010,ElectricalQuizzes. All rights reserved.
Synchronous Generator : Multiple Choice Questions (136-147)
2 of 2