PRINCIPLE OF MEASUREMENT
Mass fow measurement according to the Coriolis principle.
Almost all fuids including multi phase fuids, high viscosity
liquids (pastes and slurries)
and liquid with a certain
content of gas. For difficult
fuids (e.g. abrasive or
highly corrosive fuids) and
gases please contact
your Yokogawa
representative.
3 Series
Coriolis Mass Flow and Density Meter
GS 01R04B04-00E-E
Copyright July 2003 (R)
14th edition, August 2012 (R)
Rota Yokogawa GmbH & Co. KG
Rheinstr. 8
D-79664 Wehr
Germany
General
Specifcations
RCCT39/XR RCCT34 - 39/IR RCCF31 + RCCS30LR - 33 RCCR31
RCCS34 - 39/IR
ROTAMASS is the integral and remote type Coriolis Mass
Flowmeter. Both types have highly refned digital signal
processing electronics, so that accurate and stable mass
fow measurement is achieved.
ROTAMASS employs a fame-proof type converter case
suitable for use in the hazardous area together with its
intrinsically safety type detector.
ROTAMASSs signal processing, housing protection and its
detectors special decoupling system against external loads and
vibrations, realize high performance in real applications.
FEATURES
Field transmitter type mass fowmeter for nearly all
fuids, including high viscosity liquids, slurries and multi
phase media
Field-mount and rack-mount remote converter available
Refned digital signal processing enables accurate and
stable measurement
A special detector decoupling system makes the device
highly independent from external loads or vibrations.
Simple fow path means self-draining, food capable and
simple to clean
High accuracy and high stability over a wide range
Accurate density measurement, up to +/- 0.0005 g/cm
Concentration measurement for solutions, suspensions
and emulsions (e.g. water cut, net oil computing)
Volume fow with reference density
Two analog outputs, 2 pulse outputs or status-out and
one status-in as standard I/O
Available in explosion proof versions (ATEX, FM, IECEx,
GOST/RTN, INMETRO, NEPSI, KOSHA)
European MID approval for Custody Transfer Measurement
acc. OIML R-117-1 (see GS 01R04B07-00E-E)
FMEDA report on request, SIL 2; SIL 3 levels can be
achieved if redundant meters are used
Wide temperature range 200C to 350C
Microprocessor-based multifunction capability
EEPROM protects parameter settings and totalized
values during power failure of any duration
High visibly LCD display
HART
communication function
Optional Foundation Fieldbus communication
(see GS 01R04B05-00E-E)
Optional MODBUS
communication
Optional intrinsically safe outputs
Choice of tube materials
EN, ASME or JIS fanges as standard, others on request
GS 01R04B04-00E-E
Contents
Features Page 1
Principle of measurement Page 1
Performance specifcations Page 2
Normal operating conditions Page 3
Mechanical specifcations Page 5
Remote cable specifcation Page 5
Electrical specifcations Page 6
Hazardous area specifcations Page 7
Planning and installation hints Page 11
Dimensions Page 14
Model-, suffix- and option- codes Page 22
GS 01R04B04-00E-E 14th edition August 09, 2012-00
2
All Rights Reserved. Copyright 2003, Rota Yokogawa
Qnom is the water fow rate at about 1 bar pressure drop.
The fowmeter has a default low cut of 0.05% of Qnom.
Accuracy mass fow (refer to table 2):
Liquid RCCS30LR:
0.15% of fow rate zero stability / fow rate *100%
Liquid RCCS30 - 39/XR:
0.1% of fow rate zero stability / fow rate *100%
Gas (option /GA):
0.5% of fow rate zero stability / fow rate *100%
Accuracy volume fow :
SQRT ( (mass fow error in %) + (density error in %))
Please refer to the Yokogawa sizing software.
Accuracy based on the frequency output includes the combined
effects of repeatability, linearity and hysteresis.
Repeatability for liquids:
0.05% (zero stability/2) / fow rate *100%
Table 2 : Zero stability
Type
RCCS30
LR
RCCS30 RCCS31 RCCS32 RCCS33
kg/h 0.003 0.005 0.0085 0.019 0.048
Type RCCx34 RCCx36 RCCx38 RCCx39
RCCx39
/IR
RCCx39
/XR
kg/h 0.15 0.5 1.6 5 13 25
PERFORMANCE SPECIFICATIONS
Model
- Remote detector RCCS30LR to 33: 2 tubes, low fow design
- Remote detector RCCS34 to 39/XR : 2 tube design
- Remote feld-mount converter RCCF31
- Remote rack-mount converter RCCR31
- Integral type RCCT34 to 39/XR: 2 tube integral design
Fluid to be measured : Liquid, gas or slurries
Measurement Items : Mass fow, density, temperature
and derived from these values:
concentration, volume fow and
net fow
Mass Flow Measurement
Table 1: measuring range
Type
RCCS30
LR
RCCS30 RCCS31 RCCS32 RCCS33
Qmax t/h 0.04 0.1 0.3 0.6 1.5
Qnom t/h 0.021 0.045 0.17 0.37 0.95
Type RCCx34 RCCx36 RCCx38 RCCx39
RCCx39
/IR
RCCx39
/XR
Qmax t/h 5 17 50 170 300 600
Qnom t/h 3 10 32 100 250 500
Pressure Dependency
The stiffness of the ROTAMASS tubes is slightly line pressure
dependent. The static pressure effect of mass fow and density
can be corrected by setting the static pressure manually via menu.
Table 3 : Static pressure effect on mass fow (if not corrected)
Type
RCCS30
LR
RCCS30 RCCS31 RCCS32 RCCS33
% of
rate
per bar
SH ---- ---- ---- ---- ----
HC 0.00000 0.00000 0.00012 0.00246 0.0035
Type RCCx34 RCCx36 RCCx38 RCCx39
RCCx39
/IR
% of
rate
per bar
SS 0.00081 0.00346 0.00950 0.01058 0.02920
HC 0.00084 0.00336 0.00896 0.00808 0.01780
Type
RCCx39
/XR
% of
rate per
bar
SS 0.00740
HC ----
Density Measurement
Adjustment with water and air at calibration temperature.
Measuring range:
RCCS30LR - 38: 0.3 kg/l to 5 kg/l
RCCx39 -39/XR : 0.3 kg/l to 2 kg/l
No density measurement for gas application.
With option /K4 thermal stabilized.
For option /K6 see also Special calibrations on page 3.
Table 4: Accuracy (at calibration conditions):
Type Standard Option /K4 Option /K6
RCCS30LR 0.02 g/cm *) ------ ------
RCCS30 0.008 g/cm *) ------ ------
RCCS31 0.004 g/cm 0.001 g/cm ------
RCCS32 0.004 g/cm 0.001 g/cm 0.0005 g/cm
RCCS33 0.004 g/cm 0.001 g/cm 0.0005 g/cm
RCCx34 0.003 g/cm 0.001 g/cm 0.0005 g/cm
RCCx36 0.0022 g/cm 0.001 g/cm 0.0005 g/cm
RCCx38 0.0015 g/cm 0.001 g/cm 0.0005 g/cm
RCCx39 0.0015 g/cm 0.001 g/cm 0.0005 g/cm
RCCx39//IR 0.0015 g/cm ------ ------
RCCx39//XR 0.0015 g/cm ------ ------
*) 0.003 g/cm on request
Repeatability:
RCCS32-33, RCCx34-39/XR : 0.0005 g/cm (Std, /K4)
Static pressure effect:
Compensated if static pressure is set in the menu
Specifcation of high performance density measurement
option /K6: Density calibration
Density range : 0.3 to 2.5 kg/l
Ambient temp. range : -10C to 50C
Fluid temp. range : -50C to 150C (not /HT)
150C to 350C (/HT)
Minimum fow rate for specifed accuracy:
- RCCx36 to RCCx39 : 700 kg/h
- RCCx34 : 140 kg/h
- RCCS33 : 90 kg/h
- RCCS32 : 37 kg/h
Maximum fow rate : Qnom
Repeatability : 0.0002 g/cm
Temperature measurement:
(0.5C+0.002*abs(T
medium
-20C)) (not /HT)
(0.5C+0.008*abs(T
medium
-20C)) (/HT)
Density accuracy : for one phase liquids only
Process temperature infuence :
0.000015 g/cm * abs(Tfuid-20C)
-1.0
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 50 100 150
Flow in % of Qnom
E
r
r
o
r
i
n
%
F10.EPS
GS 01R04B04-00E-E 14th edition August 09, 2012-00
3
All Rights Reserved. Copyright 2003, Rota Yokogawa
Temperature Measurement
Temperature measuring range of converter :
Standard, /LT, /MT : -200C to 230C
Option /HT : 0C to 350C
Accuracy:
Standard (-70C to 150C) : (0.5C+0.005*abs(T
medium
-20C))
Option /MT (-70C to 230C) : (0.5C+0.005*abs(T
medium
-20C))
Option /LT (-200C to 150C): (1.0C+0.008*abs(T
medium
-20C))
Option /HT (0C to 350C) : (1.0C+0.008*abs(T
medium
-20C))
For process temperatures more than 80C higher/lower than
ambient temperature the detector should be insulated to
maintain optimum accuracy.
Heat Tracing
Heating with heat carrier, insulation and protection housing.
The max. surface temperature at the protection housing from
inner heating is 40C. Above 150C process temperature
insulation from the manufacturer is recommended. However
up to 230C process temperature the customer can insulate
the detector themselves.
Option /T1 : only insulation and protection
Option /T2 : insulation, protection and heating line
Option /T3 : like /T2 but with ventilation
Process connection for the heat carrier fuid (see table 10):
for D-type fanges : EN DN 15 PN 40 Form B1
for A-type fanges : ANSI - 150 lbs.
for J-type fanges : JIS DN15 10K
Max. pressure : PN 40
Protection class : IP54, install roof protected
For fuid temperatures below -70C select option /LT and ask
for special insulation (see also page 10).
Calibration for liquids and gases :
The ROTAMASS fowmeters are always factory calibrated
with water. Calibration Conditions:
- Water : 22.5C 12.5C
- Ambient temperature : 22.5C 12.5C
- Process Pressure : 1 to 2 bar abs
- Installation: RCCS30LR to RCCS/T38 vertical
RCCS/T39 to RCCS/T39/XR horizontal
All specifcations are based on above mentioned calibration
reference conditions, a fow calibration protocol is attached to
each instrument.
Special calibrations
- Mass-/Volume fow calibration with factory certifcate (option /K2):
Calibration with water at customer specifed fow values
according calibration order sheet.
- Mass-/Volume fow calibration with DKD/DAkkS certifcate
EN17025 (option /K5):
Calibration with water at customer specifed fow values
according calibration order sheet.
- Density calibration with factory certifcate (option /K6):
Adjustment and check with 3 different fuids, fuid temperature
infuence adjustment for low ambient temperature infuence
and thermal treatment for long term density measurement
stability, enhanced temperature measurement (see also
page 11).
Dual Seal approval (option /DS):
- Conform with ANSI/ISA-12.27.01.
- Only for use with hazardous substances.
- Up to ANSI class 900 line pressure.
- Only with FM approval option.
- For liquid application the leakage detection is realized by
software in the converter.
- For gas application options /GA and /RD (rupture disk) are
mandatory.
- Rupture disk is only for annunciation.
NORMAL OPERATING CONDITIONS
Ambient Temperature Limits
- Remote detector RCCS3 :
Standard : -50C to +80C
Option /LT : -50C to +80C
Option /MT : -50C to +80C
Option /HT : -50C to +65C
(up to 280C medium temperature)
-50C to +55C
(up to 350C medium temperature)
Terminal box temperature should not exceed 100C
- Remote converter RCCF31, RCCR31 and Integral type
RCCT3:
Display operating range : -20C to +55C)
Electronic operating range : -40C to +55C
Cold start : above -30C
Where meters are mounted in direct sunlight, it is recom-
mended to install a sunshade. This is particularly important in
countries with high ambient temperatures.
Ambient Humidity Limits : 0 to 95% RH
Process Temperature Limits
Detector :
- RCCS30LR to 33 : -50C to 150C
- RCCS34 to 39/XR : -70C to 150C
- RCCS34 to 39/XR /MT : -70C to 230C
(Range 150C - 230C
recommended with /Tx option)
- RCCS34 to 39/XR /LT : -200C to 150C
- RCCS34 to 39/IR /HT : 0C to 350C (only with /Tx option
or with /S2 and customer insulation)
Integral type :
- RCCT34 to 39/XR : -50C to 150C
For use in hazardous area see Hazardous Area Specifcations
Heat Carrier Fluid Temperature Limits
(Option /T2 or /T3 only for remote type RCCS30LR to 39/IR)
- Standard : 0C to 150C
- With option /LT : -200C to 150C
- With option /MT : 0C to 230C
- With option /HT : 0C to 350C
For fuid temperatures below -70C select option /LT and ask
for special insulation (see also page 10).
Process Pressure Limit
According to the fange ratings:
- EN PN 16 : max. 16 bar
- EN PN 40 : max. 40 bar
- EN PN 63 : max. 63 bar
- EN PN 100 : max. 100 bar
- ASME class 150 : max. 16 bar
- ASME class 300 : max. 41 bar
- ASME class 600 : max. 83 bar
- ASME class 900 : max. 124 bar
- ASME class 1500 : max. 207 bar
- JIS 10K : max. 14 bar (1.4 MPa)
- JIS 20K : max. 34 bar (3.4 MPa)
The RCCS30LR to RCCS34 have also thread connection. For
these connections the max. allowed tube pressure is the
limitation. For all other standard process connection please
fnd the max. process pressure in table 9.
GS 01R04B04-00E-E 14th edition August 09, 2012-00
4
All Rights Reserved. Copyright 2003, Rota Yokogawa
On request following maximum pressure for SL/SH up to 27C
(RT=Room Temp.):
- RCCS30LR : 400 bar
- RCCS30 : 400 bar
- RCCS31 : 350 bar
- RCCS32 : 285 bar
- RCCS33 : 285 bar
- RCCS34 / RCCT34 : 260 bar
- RCCS36 / RCCT36 : 210 bar
- RCCS38 / RCCT38 : 175 bar
- RCCS39 / RCCT39 : 135 bar
- RCCS39/IR / RCCT39/IR : 110 bar
- RCCS39/XR / RCCT39/XR : 95 bar
For higher medium temperatures maximum tube pressure
needs to be derated as follows :
up to 50C : 4% derating
51 to 100C : 11% derating
101 to 150C : 20% derating
151 to 230C : 30% derating
231 to 350C : 38% derating
Higher pressure on request.
The maximum process pressure of a single instrument is given
by the lower value either of the process connections (table 9)
or tubes. The maximum temperature and process pressure
limits of an instrument are marked on the name plate as TS
and PS.
The given temperature/pressure ranges are calculated and
approved without corrosion or erosion effects. The customer
is fully responsible to select proper materials to withstand his
corrosive or erosive conditions. In case of heavy corrosion
and/or erosion the instrument may not withstand the pressure
and an incident may happen with human and/or environmental
harm. Yokogawa will not take any liability regarding damage
caused by corrosion / erosion. If corrosion/erosion may happen,
the user has to check periodically if the necessary wall thick-
ness is still in place.
Gas Content Limits for Liquid/Gas Mixtures
Gas content limit is defned as the amount of gas in a liquid/
gas mixture which generates an error in the converter. The
gas content limit is dependent on viscosity,
surface tension and bubble size of the liquid/gas mixture.
Furthermore it is highly fow rate dependent (the higher the
fow rate, the lower the gas content limits). The stated values
are for a fow of 50% of Qnom and water/air without /HP:
Model Gas fraction
- RCCS30LR to RCCS32 : no limitation
- RCCS33 non-Ex type : no limitation
- RCCS33 Ex type : approx. 35%
- RCCx34 : no limitation
- RCCx36 : approx. 50%
- RCCx38 : approx. 30%
- RCCx39 : approx. 7%
- RCCx39/IR : approx. 3%
- RCCx39/XR (with /HP) : approx. 2%
With option /HP the gas content limits are improved.
With liquid/gas mixtures the specifed mass fow accuracy will
not be achieved.
For short time aeration a function can be activated to keep
the current outputs constant during the aeration time.
Other 2 Phase Flow, liquid/solid and liquid/liquid
Two phase fow can generate minus span errors. The errors
are proportional to the difference in density between the 2
phases and the amount of the second phase. If the particles
or droplets are very small no errors will be generated.
Secondary Containment
Model Typical rupture
pressure
Option /J1
pressure test *)
RCCS30LR-33 65 bar ---
RCCx34-36 120bar 60 bar
RCCx38 120 bar 40 bar
RCCx39-39/IR 80 bar 10 bar
RCCx39/XR on request ---
RCCx39/XR/HT 50 bar ---
*) Pressure test with safety factor S=1.1
However if the detector housing is exposed to this pressure
it will deform and measurement will be strongly infuenced.
Therefore the pressure test of the housing (option /J1) can
only be done as shown in above table.
Power Supply and Power Consumption
- AC-/DC-type : For details see Electrical Specifcations
GS 01R04B04-00E-E 14th edition August 09, 2012-00
5
All Rights Reserved. Copyright 2003, Rota Yokogawa
REMOTE CABLE RCCY03 SPECIFICATION
Li2Y(St)/CY 3x2 AWG24 + 1x3 AWG20
pair/triple shielded; pair/triple twisted; overall shielding
RCCY033/034 and RCCY031/032/KS1: fame propagation acc. IEC 60332-1.
Table 6 : Cable specifcations
Model code Temperature
range
Wire gauge Resistance of
loop
Capacitance
wire/wire
Capacitance
wire/shield
Inductance
wire/wire
RCCY031/032 -50 to +70C
AWG 24
AWG 20
190 /km
70 /km
157 nF/km
193 nF/km
249 nF/km
290 nF/km
0.60 mH/km
0.65 mH/km
RCCY031/032 /KS1 -50 to +70C
AWG 24
AWG 20
190 /km
70 /km
157 nF/km
193 nF/km
249 nF/km
290 nF/km
0.60 mH/km
0.65 mH/km
RCCY033/034 -30 to +105C
AWG 24
AWG 20
177 /km
70 /km
175 nF/km
145 nF/km
350 nF/km
290 nF/km
0.80 mH/km
0.70 mH/km
RCCY033/034 /KS1 -30 to +105C
AWG 24
AWG 20
177 /km
70 /km
175 nF/km
145 nF/km
350 nF/km
290 nF/km
0.80 mH/km
0.70 mH/km
MECHANICAL SPECIFICATIONS
Protection Class
- RCCT3x : IP66/67
- RCCF31 : IP66/67
- RCCS3x : IP66/67
- RCCR31 : IP20
Materials
- Detector housing : Stainless steel 304/1.4301
- Detector terminal box : 316L/1.4404
- Detector gas flling plug: 1.4305
- Detector insulation housing
: Stainless steel 304/1.4301
- Detector rupture disk (/RD)
: 316L
- Field- mount converter housing
: Aluminium alloy with Polyurethane
corrosion-resistant coating or
epoxy coating (option /X1)
- Field- mount converter mounting bracket:
: Stainless steel 304/1.4301
- Rack- mount converter housing
: Aluminium
Coating Color
- Field-mount converter case
: Mint green
Wetted Parts
- RCCS30LR to 33 :
Measuring tubes : Ni-Alloy C-22/2.4602
Process connections : 316L/1.4404
- RCCx34 to 39/IR :
Measuring tubes and process connection
: 316L/1.4404/1.4435 or
Measuring tubes and fange face
: Ni-Alloy C-22/2.4602
- RCCx39/XR :
Measuring tubes and process connection
: 316L/1.4404/1.4435
Table 5 : Diameter of measuring tubes
Type
RCCS30
LR
RCCS30 RCCS31 RCCS32 RCCS33
Inner
diameter
mm 0.9 1.2 2.1 3 4.5
Wall thick-
ness
mm 0.15 0.2 0.25 0.25 0.4
Type RCCx34 RCCx36 RCCx38 RCCx39
RCCx39
/IR
RCCx39
/XR
Inner
diameter
mm 7.7 13.4 22.1 37.2 54.5 82.50
Wall thick-
ness
mm 0.89 1.24 1.65 2.6 2.9 3.2
Pressure Equipment Directive 97/23/EC
RCCS30LR- RCCS33 : SEP
FLUID GROUP 1 : MODULE H, CATEGORY III
FLUID GROUP 2 : RCCX34-RCCX38: SEP
: RCCX39-RCCS39/XR: CAT.I
For all Process Connections
: CRN 0F12074.5
Vibration Test : Acc. IEC 60068-2-64
GS 01R04B04-00E-E 14th edition August 09, 2012-00
6
All Rights Reserved. Copyright 2003, Rota Yokogawa
ELECTRICAL SPECIFICATIONS
Power Supply
- AC- type : 90 V to 264 V AC
- AC- Ex-type : 90 V to 250 V AC
- DC- type : 20.5 V to 28.8 V DC
Power consumption : max. 25 VA / 10 W
External circuit breaker rating : 5 A, 250 V (In the converter
no power switch is installed).
Fuse on Base Board
- AC- type : 2 A, T, breaking capacity 1500A
- DC- type : 2 A, T, breaking capacity 1500A
I/O Signals
- Two active current outputs: Iout1, Iout2
4 to 20 mA DC, galvanic separated from other signals,
Load resistance : 20 to 600
Failure current according NAMUR NE43
Ambient temperature effect : < 0.05% of span/10C
Linearity : 0.008 mA = 0.05% of span
Setting range URV for liquids: 5 to 100% of Qnom
Setting range URV for gases: 1 to 100% of Qnom
- Two pulse outputs / status outputs : Pout, Sout
Passive transistor contact output, 30 V DC, 200 mA
Output rate
Output 1 : 0 to 10000 pulses/s
Output 2 : 0 to 2000 pulses/s
Option /NM : passive, according EN 60947-5-6
Option /AP : active output, 12 V, 6 mA, R
L
> 10 k
Active pulse output is not isolated from current output 2
As frequency output
Output 1 : 20 Hz to 10000 Hz
Output 2 : 20 Hz to 2000 Hz
- Status input : Voltage-free contact
Closed : < 200
Open : > 100 k
Option /KF2, /EF2, /UF2: 2 intrinsic safe outputs
- One passive current output (additional power supply
needed) : Iout
4 to 20 mA DC, galvanic separated from other signals.
Supply voltage 10.5 V to 30 V DC (without HART
), 165 mA
Supply voltage 16.75 V to 30 V DC (with HART
), 165 mA
Load resistance : 20 ... 600
Ambient temperature effect : < 0.05% of span/10C
- One pulse output / status output : Pout
Passive transistor contact output, 30 V DC, 100 mA
Output rate : 0 to 2000 pulses/s
As frequency output : 20 Hz to 2000 Hz
Option /NM : passive, according EN 60947-5-6
- No status input
Digital Communication
- HART
communication (/MB1)
- Physical interface RS485 as two wire data bus according
EIA/TIA-485
- Maximal bus length is depending from bus topology and
communication speed.
- Addresses: 1 to 247
- Baud rates: 1200, 2400, 4800, 9600, 19200, 38400,
57600, 76800, 115200
- Data formats: E/1, O/1, N/1, N/2 (parity/stop bits)
- Modes: RTU, ASCII
Setting Functions
Parameter setting is possible by using the infrared switches
on the display or with HART
1
2
3
Integral Type RCCT39/XR
see table 11
L1 5 see table 11
Dimensions in mm
Weight: RCCT39/XR: 295 ... 325 kg (650 ... 720 lb) depends on flanges
Dimensions in mm
Weight: RCCS39/XR: 290 ... 320 kg (640 ...710 lb) depends on flanges
Integral Type RCCT39
Note: The fange dimensions are depended on its respective size and pressure rating.
Model L1 L2 L3 H1 H2 H3 H4 W1 W2 Weight
RCCT39 [mm] see table 11 850 388 380 240 306 135 129 160 64 kg
Dimensions in [mm]. Weights with smallest fanges.
GS 01R04B04-00E-E 14th edition August 09, 2012-00
16
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote feld-mount Converter RCCF31
75
2
0
1
3
0
5
1
7
1
2
0
6
4
85
(148)
102
1
2
3
9
1
.
6
32 29 49
144 122
2
0
1
3
0
5
75
85
148
6
4
1
2
0
1
7
1
2
3
9
1
.
6
32 29 29
102
124 122
F2.EPS
1
2
2
1
2
2
Weight with bracket: about 5.5 kg (depends on type)
Without window
With window
Remote rack-mount Converter RCCR31
Terminal Board Cassette, side view Cassette, front view
228 107 (21TE)
1
2
8
(
3
H
E
)
Dimensions in mm
19-inch rack, acc. IEC / DIN EN 60297-3-101
Weight: 1.5 kg
GS 01R04B04-00E-E 14th edition August 09, 2012-00
17
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote Detector RCCS30LR - 33
Option /PD
Mounting set for DN50 tube
25 58 47
210
180
150
8
.
5
1
1
0
1
5
0
s
.
t
a
b
l
e
1
1
3
9
8
Weight (without flanges): 5.2 kg (11.5 lb) Weight (without flanges): 6.2 kg (13.5 lb)
1
0
2
8
9
126
201
51
29 20 25
Option /S2
Dimensions in mm
111 (RCCS30LR)
111 (RCCS30)
99 (RCCS31)
89 (RCCS32)
55 (RCCS33)
Remote Detector RCCS34 - 38 and 39/IR
Note: The fange dimensions depend on size and pressure rating of the fange.
Model L1 L2 L3 H1 W1 W2 H4 H5 H6 Weight
RCCS34 [mm] see table 11 272 212 177 60 80 80 138 218 9.5 kg
RCCS36 [mm] see table 11 400 266 230 76 90 80 138 218 13 kg
RCCS38 [mm] see table 11 490 267 269 89 110 100 148 228 22 kg
RCCS39/IR [mm] see table 11 870 454 435 154 200 200 198 278 110 kg
Dimensions in [mm]. Weights with smallest fanges.
GS 01R04B04-00E-E 14th edition August 09, 2012-00
18
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote Detector RCCS39/XR
see table 11
L1 5 see table 11
Dimensions in mm
Weight: RCCT39/XR: 295 ... 325 kg (650 ... 720 lb) depends on flanges
Dimensions in mm
Weight: RCCS39/XR: 290 ... 320 kg (640 ...710 lb) depends on flanges
Remote Detector RCCS39
Note: The fange dimensions are depended on its respective size and pressure rating.
Model L1 L2 L3 H1 W1 W2 H4 H5 H6 Weight
RCCS39 [mm] see table 11 850 388 380 129 160 135 166 246 60 kg
Dimensions in [mm]. Weights with smallest fanges.
L15
L2
L3
W1
H
4
H
5
H
1
H
6
102
102
8
0
Option /S2 and /MT
W
2
GS 01R04B04-00E-E 14th edition August 09, 2012-00
19
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote Detector RCCS39/XR with option /HT
2
8
0
683
1140
273
2
8
0
8
9
2
3
1
8
8
0
50
102 L1 5 s. table 11
F22.EPS
GS 01R04B04-00E-E 14th edition August 09, 2012-00
20
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote Detector RCCS34 - 39/IR with option /Tx (Insulation / Heating)
Note: The fange dimensions depend on size and pressure rating of the fange.
Model L1 L4 L5 D1 D2 H6 H7 H8 H9 W3 Weight
RCCS34 mm see table 11 420 310 200 330 218 411 273 138 240 18 kg
RCCS36 mm see table 11 540 439 250 380 218 464 326 138 260 25 kg
RCCS38 mm see table 11 640 530 250 430 228 524 376 148 260 37 kg
RCCS39 mm see table 11 1000 894 350 545 245 668 503 165 302 95 kg
RCCS39/IR mm see table 11 1040 932 350 570 278 726 528 198 342 125 kg
Weights with smallest fanges including insulation cover and heat tracing.
Standard heating connection according table 10.
GS 01R04B04-00E-E 14th edition August 09, 2012-00
21
All Rights Reserved. Copyright 2003, Rota Yokogawa
Table 10: Heat tracing connection types depending on process connection type
Process connection Standard heating connection *)
Ax ASME - 150
Dx EN DN 15 PN 40
Jx JIS 10K DN15
S2 ; S4 EN DN 15 PN 40
S8 ASME - 150
G9 EN DN 15 PN 40
T9 ASME - 150
*) others on request
Adapter 1/2 NPT - G1/2 (option /AD2)
N1 N2 D B C L1 L2 L Weight (kg)
1/2 NPT G1/2 15 27 30 19 23 45 0.07
Unit: mm
Remote Detector RCCS30LR - 33 with option /Tx (Insulation / Heating)
ventilation optional /T3
heating connection
optional /T2 or /T3
160
176
180
270
3
5
0
1
2
6
1
6
5
4
2
5
2
9
9
1
0
2
F21.EPS Dimensions in mm
L1 3 s. table on page 4
1
3
4
GS 01R04B04-00E-E 14th edition August 09, 2012-00
22
All Rights Reserved. Copyright 2003, Rota Yokogawa
MODEL, SUFFIX AND OPTION CODES
Integral Type RCCT3, Model and Suffix Code
Model Suffix Code Description Restrictions
RCCT34
RCCT36
RCCT38
RCCT39
RCCT39/IR
RCCT39/XR
Nominal Value : 3 t/h = 50 kg/min
Nominal Value : 10 t/h = 170 kg/min
Nominal Value : 32 t/h = 533 kg/min
Nominal Value : 100 t/h = 1670 kg/min
Nominal Value : 250 t/h = 4170 kg/min
Nominal Value : 500 t/h = 8340 kg/min only with /HP
Power supply -A
-D
90 - 264 V AC
24 V DC
Indicator direction H1
H2
V0
N0
Detector installation horizontal, tubes down
Detector installation horizontal, tubes up
Detector installation vertical
Without indicator
recom. for liquid service
recom. for gas service /GA
Cable conduit connection M
A
M20 x 1.5, female thread with cable glands
ANSI NPT, female thread without cable glands mandatory with /FF1, /FF2
Process connection size
1)
23
01
02
04
05
06
08
10
12
15
20
DN 15,
DN 25, 1
DN 40, 1
DN 50, 2
DN 65, 2
DN 80, 3
DN 100, 4
DN 125, 5
DN 150, 6
DN 200, 8
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
Process connection rating and style
1)
A1
A2
A3
A4
A5
D2
D4
D5
D6
J1
J2
S2
S4
S8
G9
T9
ASME fange class 150, process connection dim. + facing acc. ASME B16.5
ASME fange class 300, process connection dim. + facing acc. ASME B16.5
ASME fange class 600, process connection dim. + facing acc. ASME B16.5
ASME fange class 900, process connection dim. + facing acc. ASME B16.5
ASME fange class 1500, process connection dim. + facing acc. ASME B16.5
EN fange PN 16, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 40, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 63, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 100, process connection dim. + facing acc. EN 1092-1 Form B1
JIS fange 10K, JIS B 2220
JIS fange 20K, JIS B 2220
Thread acc. DIN 11851
Clamp, process connection dimensions acc. DIN 32676
Clamp, process connection dim. acc. Tri-Clover (Tri-Clamp) and Mini Clamp
G, female thread
NPT female thread
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
Material of wetted parts
1)
SL
HC
Stainless steel 316L (1.4404)
Hastelloy C-22 (2.4602) only RCCT34 to 39/IR
1)
see selection table Process connection and materials (table 11)
Integral Type RCCT3, Option Code :
Options Option
code
Description Restrictions
Hazardous Area Approvals /KF1
/KF2
/FF1
/FF2
/EF1
/EF2
/UF1
/UF2
/NF1
/NF2
ATEX Flame proof converter + Intrinsic safe detector
ATEX Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector +
2 active analog outputs + 2 passive pulse outputs + 1 status input
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector +
1 passive analog output + 1 passive pulse output
IECEx Flame proof converter + Intrinsic safe detector
IECEx Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
INMETRO Flame proof converter + Intrinsic safe detector
INMETRO Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
NEPSI Flame proof converter + Intrinsic safe detector
NEPSI Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit A; with /HP not for groups
A and B
only with cable conduit A; with /HP not for groups A
and B
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
Custody Transfer Measurement
acc. OIML R 117-1
/Q01 European MID Approval (fuids other than water) (refer to GS 01R04B07-00E)
GOST /QR1
/QR2
/QR3
Primary Calibration and Test Confrmation valid in Russia
Primary Calibration and Test Confrmation valid in Kazakhstan
Primary Calibration and Test Confrmation valid in Uzbekistan
see page 9
see page 9
see page 9
Dual Seal Approval /DS
/RD
Dual Seal approval (conform with ANSI/ISA-12.27.01)
Rupture disk, rupture pressure 20 bar, nominal diameter 8 mm
only with /FF1; not with process connection A5;
preferable with /GA, mandatory if /DS+/GA is selected
GS 01R04B04-00E-E 14th edition August 09, 2012-00
23
All Rights Reserved. Copyright 2003, Rota Yokogawa
Integral Type RCCT3, Option Code (continued)
Options Option
code
Description Restrictions
High Driving Power /HP High Driving Power not for RCCT34, recommended for RCCT36 to 39,
strongly recommended for RCCT39/IR, mandatory for
RCCT39/XR
1);
Please see Hazardous Area Specifcations
Communication /MB1 Modbus communication protocol for selected parameters and values not with /Q01, /KF2, /EF2, /UF2, /FF2, /NF2
Active Pulse Output /AP One active pulse output not with /KF2, /EF2, /UF2, /NF2, /NM
NAMUR Switch /NM One pulse output acc. to EN 60947-5-6 (NAMUR) not with /AP
Tag Number /BG With customer specifed tag number on name plate max. 16 digits
HART
Tag Number (Software Tag) /BT1 With customer specifed tag number for HART
DN 15,
DN 25, 1
DN 40, 1
DN 50, 2
DN 65, 2
DN 80, 3
DN 100, 4
DN 125, 5
DN 150, 6
DN 200, 8
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
Process connection rating and style
1)
A1
A2
A3
A4
A5
D2
D4
D5
D6
J1
J2
S2
S4
S8
G9
T9
ASME fange class 150, process connection dim. + facing acc. ASME B16.5
ASME fange class 300, process connection dim. + facing acc. ASME B16.5
ASME fange class 600, process connection dim. + facing acc. ASME B16.5
ASME fange class 900, process connection dim. + facing acc. ASME B16.5
ASME fange class 1500, process connection dim. + facing acc. ASME B16.5
EN fange PN 16, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 40, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 63, process connection dim. + facing acc. EN 1092-1 Form B1
EN fange PN 100, process connection dim. + facing acc. EN 1092-1 Form B1
JIS fange 10K, JIS B 2220
JIS fange 20K, JIS B 2220
Thread acc. DIN 11851
Clamp, process connection dimensions acc. DIN 32676
Clamp, process connection dim. acc. Tri-Clover (Tri-Clamp) and Mini Clamp
G female thread
NPT female thread
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
Material of wetted parts
1)
SH
SL
HC
316L (1.4404) and Hastelloy C-22 (2.4602) for tube
Stainless steel 316L (1.4404)
Hastelloy C-22 (2.4602)
only RCCS30LR to 33
only RCCS34 to 39/XR
only RCCS34 to 39/IR
1)
see selection table Process connection and materials (table 11)
GS 01R04B04-00E-E 14th edition August 09, 2012-00
25
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote Detector RCCS3, Option Code
Options Option
code
Description Restrictions
Hazardous Area Approvals
1)
/KS1
/FS1
/ES1
/US1
/NS1
ATEX intrinsically safe approval
FM intrinsically safe approval for USA + Canada
IECEx intrinsically safe approval
INMETRO intrinsically safe approval for Brazil
NEPSI intrinsically safe approval for China
only with cable conduit A
Custody Transfer Measurement
acc. OIML R 117-1
/Q01 European MID Approval (fuids other than water) (refer to GS 01R04B07-00E)
GOST
1)
/QR1
/QR2
/QR3
Primary Calibration and Test Confrmation valid in Russia
Primary Calibration and Test Confrmation valid in Kazakhstan
Primary Calibration and Test Confrmation valid in Uzbekistan
see page 9; not with RCCS30LR
see page 9; not with RCCS30LR
see page 9; not with RCCS30LR
Dual Seal Approval /DS
/RD
Dual Seal approval (conform with ANSI/ISA-12.27.01)
Rupture disk, rupture pressure 20 bar, nominal diameter 8 mm
only RCCS34 to 39/XR; only with /FS1; not with pro-
cess connection A5
only RCCS34 to 39/XR, preferable with /GA, not with /
Tx, mandatory if /DS + /GA is selected
Tag Number /BG With customer specifed tag number on name plate max. 16 digits
Flange Facing /DN
/RJ
Flange with safety grooves acc. to EN 1092-1 form D
Ring Type Joint Flanges
only for D2 to D6; not HC, for RCCS30LR only for 01D4
or 01D6
only for A3, A4, A5; not HC, for RCCS30LR only for
01A3 or 01A5
Gas Measurement /GA Gas measurement, special factory adjustments and settings select affiliated RCCF31 or RCCR31 with /GA;
to be conform with ANSI/ISA-12.27.01 select /RD
Low temperature version /LT -200C < T
medium
< 150C not RCCS30LR to 33; not with /KS1, /FS1, /ES1, /US1,
/MT, /HT, /T1, /T2, /T3
Extended temperature range /MT -70C < T
medium
< 230C not RCCS30LR to 33; always with /S2 or /Tx;
remote cable RCCY033/034 recommended
High temperature version /HT T
medium
up to 350C RCCS34 to 39/IR only with /Tx or /S2 (customer insula-
tion required); RCCS39/XR only with /S2;
remote cable RCCY033/034 recommended
Special Calibration /K2
2)
/K4
/K5
2)
/K6
Custom 5 pts mass-/volume-fow calibration using water with factory certifcate
(traceable to German national standards)
Density adjustment + thermal treatment; (accuracy: 0.001 g/cm)
Custom 10 pts mass-/volume-fow calibration using water with DKD certifcate
(according EN-17025:2005)
Density calibration with 3 different fuids incl. individual temperature compensation
with certifcate (accuracy: 0.0005 g/cm)
only RCCS31 to 39; not with /GA
only RCCS32 to 39; not with /GA; not with /LT;
not with /MT; only available if converter is also ordered
Certifcates /P2
/P3
/P6
/P8
/H1
/WP
Certifcate of compliance with the order acc. to EN 10204:2004 -2.1
As /P2 + Test report acc to EN 10204: 2004 -2.2 (QIC)
Material certifcate acc to EN 10204: 2004 -3.1
Pressure test report measuring system
Oil and fat free for wetted surface acc. to ASTM G93-03 level C
WPS acc. DIN EN ISO 15609-1 (Welding Procedure Specifcation)
WPQR acc. DIN EN ISO 15614-1 (Welder Performance Qualifcation Record)
WQC acc. DIN EN 287-1 (Welder Qualifcation Certifcate)
only for butt weld between process connection and
fow divider; not for HC
Sanitary Type /SF1
/SF2
/SA
/SE
Surface roughness Ra = 0.8 m
As /SF1 + Test report roughness of wetted parts
As /SF2 + 3A- declaration of conformity and 3A- mark
As /SF2 + EHEDG- certifcate
only RCCS34 to 39/IR; only process connections S2,
S4, S8; see also restrictions in table 11
not with process connection S2
not with process connection S2
Mounting set /PD 2 inch pipe mounting set only RCCS30LR to 33; not with /Tx; recommended for
RCCS30LR and RCCS30
Housing Pressure Test /J1 Rupture pressure proof test and certifcate (see page 4) not for RCCS30LR to 33 + RCCS39/XR
Customer insulation / Heating /S2 Terminal box on extension for high or low process temperature not with /T1 ... /T3
Factory Insulating / Heating /T1
/T2
/T3
Insulation
Insulation + Heat carrier heating
Insulation + Heat carrier heating with ventilation (purge)
not for RCCS39/XR
not for RCCS39/XR
not for RCCS39/XR
X-Ray Examination /RT X-ray examination of fange welding RCCS30LR to 33 and RCCS34 with /K4, /K6 or /LT
only one-sided
PMI Examination /PM4
/PM6
PAMI test (4 test points: process connection inlet + outlet, fow divider inlet +
outlet)
3)
PAMI test (6 test points: process connection inlet + outlet, measuring tubes, fow
divider inlet + outlet)
3)
only RCCS30LR to 33
not RCCS30LR to 33
Dye Penetration Test /PT Dye penetration test of fange welding
Stainless steel cable gland /BS Cable gland stainless steel
Delivery to Japan /PJ For meters which are delivered to Japan
Delivery to Korea /KC With KC-mark for Korea
Quick Delivery /QD Delivery within 24 hours from factory Delivery scope please refer to Quick Delivery Possibili-
ties or contact Yokogawa sales office.
Special order /Z Special design must be specifcation an extra sheet
1)
Select affiliated converter RCCF31/RCCR31 with the same approval type (e.g. ATEX).
2)
Calibration order sheet must be delivered with the order. This is available on the Flow Center Page at Coriolis/RCCx3/Technical Information.
3)
Measuring tube PAMI test is performed per delivery batch.
GS 01R04B04-00E-E 14th edition August 09, 2012-00
26
All Rights Reserved. Copyright 2003, Rota Yokogawa
Remote feld-mount Converter RCCF31, Model, Suffix and Option Code
Model Suffix Code Option
Code
Description Restrictions
RCCF31 Remote feld-mount converter to be connected to RCCS3;
when ordered without detector combination option /NC must be selected
Power supply -A
-D
90 - 264 V AC
24 V DC
Indicator direction H2
N0
With indicator
Without indicator
Cable conduit connection M
A
M20 x 1.5, female thread with cable glands
ANSI NPT, female thread, only cable gland for detector connection mandatory with /FF1, /FF2
Hazardous Area Approvals /KF1
/KF2
/FF1
/FF2
/EF1
/EF2
/UF1
/UF2
/NF1
/NF2
ATEX Flame proof converter + Intrinsic safe detector output
ATEX Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 2 active analog outputs + 2 passive pulse outputs + 1 status input
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector
output + 1 passive analog output + 1 passive pulse output
IECEx Flame proof converter + Intrinsic safe detector output
IECEx Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
INMETRO Flame proof converter + Intrinsic safe detector
INMETRO Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
NEPSI Flame proof converter + Intrinsic safe detector output
NEPSI Flame proof converter + Intrinsic safe detector output + Intrinsic safe
outputs
with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit A; with /HP not for groups
A and B
only with cable conduit A; with /HP not for groups
A and B
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
Custody Transfer Measurement
acc. OIML R 117-1
/Q01 European MID Approval (fuids other than water) (refer to GS 01R04B07-00E)
GOST
1)
/QR1
/QR2
/QR3
Primary Calibration and Test Confrmation valid in Russia
Primary Calibration and Test Confrmation valid in Kazakhstan
Primary Calibration and Test Confrmation valid in Uzbekistan
see page 9
see page 9
see page 9
Communication /MB1 Modbus communication protocol for selected parameters and values not with /Q01, /KF2, /EF2, /UF2, /FF2, /NF2
High Driving Power /HP High Driving Power not for combination with RCCS30LR to 34,
recommended for combination with RCCS36 to 39,
strongly recommended for combination with RCCS39/IR,
mandatory for combination with RCCS39/XR
4)
Please see Hazardous Area Specifcations
Active Pulse Output /AP One active pulse output not with /KF2, /EF2, /UF2, /NF2, /NM
NAMUR Switch /NM One pulse output acc. EN 60947-5-6 (NAMUR) not with /AP
Tag Number /BG With customer specifed tag number on name plate max. 16 digits
HART
Tag Number (Software Tag) /BT1 With customer specifed tag number for HART
Tag Number (Software Tag) /BT1 With customer specifed tag number for HART