Grundfosliterature 3081235
Grundfosliterature 3081235
Grundfosliterature 3081235
Table of contents
1.
Introduction
Introduction
Applications
Overall construction features
3
3
4
2.
Performance range
3.
Identification
Type key
Nameplate
6
7
Selection of product
Ordering a pump
Product range
9
11
Variants
14
List of variants
14
Construction
15
4.
5.
6.
7.
SL1
15
SLV
21
Material specification, SL1 and SLV standard pumps
27
Material specification, SLV Q variants
28
8.
9.
Product description
29
Features
Operating conditions
Motor range
Pump controllers
Frequency converter operation
Wiring diagrams
29
31
31
32
33
34
36
37
38
38
38
38
11. Accessories
Installation systems
Other accessories
Level controllers
40
40
46
52
64
76
82
88
94
100
120
140
148
148
149
150
154
154
155
Introduction
Applications
industrial wastewater
municipal wastewater
Introduction
1. Introduction
domestic wastewater
SL1
residential buildings
factories/industry.
SLV
Fig. 1
1
Introduction
2
Performance range
2. Performance range
The figure below shows the performance range of SL1
and SLV sewage and wastewater pumps. It gives an
overview of the various sizes and impeller types.
Note: For information about the performance range of
each individual pump, see pages 40 to 147.
If your required duty point exceeds the performance
range below, please see the Grundfos S range data
booklets available in WebCAPS.
H
[m]
60 Hz
50
40
30
5
20
15
4
10
8
6
5
4
2
2
10
20
Pump type
SL1.50.65.22
SL1.50.65.30
SL1.50.65.40
SL1.50.80.22
SL1.50.80.30
SL1.50.80.40
SL1.80
SL1.100
15
40
Curve No
2
3
20
60
30
80
100
Pump type
SLV.65.65.22
SLV.65.65.30
SLV.65.65.40
SLV.65.80.22
SLV.65.80.30
SLV.65.80.40
SLV.80
SLV.100
40
50
100
Q [l/s]
200
Q [m/h]
Curve No
5
6
3
Identification
3. Identification
Type key
The pump can be identified by means of the type
designation. The type designation is stated on the
nameplate of the pump. See below example of a type
designation. The example shows the following:
SLV pump with 80 mm free spherical passage and
80 mm DIN outlet.
motor with 4 kW shaft power, sensor version,
ATEX-approved version, 4-pole, for 3 x 380-415 V
50 Hz, and star-delta starting
Q variant i.e. cast iron pump fitted with a cast
stainless steel SuperVortex impeller
Code
Example
SL
Pump type:
Grundfos wastewater pump
1
V
Impeller type:
Single-channel impeller
SuperVortex (free flow) impeller
50
65
80
100
65
80
100
150
Pump discharge:
DN 65
DN 80
DN 100
DN 150
40
Blank
A
Sensor version:
Standard
Sensor version
Blank
Ex
Pump version:
Non-explosion-proof pump (standard)
Explosion-proof pump
2
4
Number of poles:
2-pole
4-pole
Frequency:
60 Hz
0F
0G
1F
1G
Blank
A
B
Generation:
1st generation
2nd generation
3rd generation
Blank
Q
Material in pump:
Complete pump in cast iron
Cast iron pump with stainless steel impeller
Blank
Z
Customisation
Pump in standard range
Custom-built pump
SL
V.
80.
80.
40.
A.
Ex.
4.
6.
OH.
Q.
3
Identification
Nameplate
14
1
2
3
4
5
6
7
8
9
10
11
12
13
Fig. 2
Pos.
16
17
18
19
20
21
22
23
24
15
E
Nameplate
Description
Type designation
Serial number
Maximum head
Rated voltage, D
10
Rated voltage, Y
11
Frequency
12
Country of production
13
CSA mark
14
FM mark
15
16
17
Power factor
18
Number of phases
19
Rated speed
20
Service factor
21
22
23
Insulation class
24
4
Selection of product
4. Selection of product
Ordering a pump
Custom-built variants
3. explosion-proof version
4. accessories
5. pump controller.
Explosion-proof version
Pump type
Use the following table to identify which type of pump
that best meets your needs. The table is for guidance
only.
Description
SL1 SLV
X
X
X
X
X
X
X
X
X
Application
Storm water
Groundwater
Drainage and surface water
Drainage and surface water with small impurities
Abrasive surface water
Wastewater with long fibres e.g. from laundries
Domestic wastewater with discharge from toilets
Municipal sewage
Sewage from commercial buildings
Industrial process water with fibres/solids
Industrial process water with solids
Industrial process water without solids and fibres
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Accessories
Depending on the installation type, accessories may
be required. See section Installation systems on page
148 for selection of the correct accessories.
Note: Ordered accessories are not fitted from factory.
Pump controller
The following controllers are available:
LC/LCD 107 with air bells
LC/LCD 108 with float switches
LC/LCD 110 with level electrodes
Grundfos Dedicated Controls
Pump
SLV.65.65.22.2.60G
Product no.
96970674
5
Product range
5. Product range
SL1 pump range
Voltage
Pump type
SL1.50.65.22
SL1.50.65.30
SL1.50.65.40
SL1.50.80.22
SL1.50.80.30
SL1.50.80.40
SL1.80.100.15
SL1.80.100.22
SL1.80.100.30
SL1.80.100.40
SL1.80.100.55
SL1.80.100.75
SL1.80.80.15
SL1.80.80.22
SL1.80.80.30
Sensor
Explosion
Poles
proof
Hz
3 x 220-277 V,
DOL
3 x 380-480 V
DOL
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V
Y/D
Stainless
steel impeller
[.A]
[.EX]
[.2]
[.6]
[0F]
[0G]
[1F]
[1G]
[.Q]
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
96973025
96971643
96971177
96972110
96973027
96971649
96971183
96972116
96973029
96971657
96971191
96972124
96973031
96971665
96971199
96972132
96973033
96971671
96971205
96972138
96973035
96971679
96971213
96972146
96973051
96971731
96971265
96972198
96973053
96971745
96971279
96972212
96973056
96971743
96971277
96972210
96973058
96971751
96971285
96972218
96973060
96971759
96971293
96972226
96973062
96971767
96971301
96972234
96973037
96971687
96971221
96972154
96973039
96971709
96971243
96972176
96973041
96971701
96971235
96972168
96970636
96971576
96971111
96972044
96970637
96971577
96971112
96972045
96970638
96971578
96971113
96972046
96970639
96971579
96971114
96972047
96970640
96971580
96971115
96972048
96970641
96971581
96971116
96972049
96970659
96971589
96971124
96972057
96970838
96971769
96971303
96972236
96970661
96971591
96971126
96972059
96970662
96971592
96971127
96972060
96970663
96971593
96971128
96972061
96970664
96971594
96971129
96972062
96970652
96971582
96971117
96972050
96970653
96971583
96971118
96972051
96970654
96971584
96971119
96972052
96970711
96971642
96971176
96972109
96970717
96971648
96971182
96972115
96970725
96971656
96971190
96972123
96970733
96971664
96971198
96972131
96970739
96971670
96971204
96972137
96970747
96971678
96971212
96972145
96970767
96971698
96971232
96972165
96970805
96971736
96971270
96972203
96970811
96971742
96971276
96972209
96970819
96971750
96971284
96972217
96970827
96971758
96971292
96972225
96970835
96971766
96971300
96972233
96970764
96971695
96971229
96972162
96970761
96971692
96971226
96972159
96970768
96971699
96971233
96972166
96970714
96971645
96971179
96972112
96970723
96971654
96971188
96972121
96970731
96971662
96971196
96972129
96970736
96971667
96971201
96972134
96970745
96971676
96971210
96972143
96970753
96971684
96971218
96972151
96970802
96971733
96971267
96972200
96970841
96971772
96971306
96972239
96970817
96971748
96971282
96972215
96970825
96971756
96971290
96972223
96970833
96971764
96971298
96972231
96970665
96971595
96971130
96972063
96970758
96971689
96971223
96972156
96970786
96971717
96971251
96972184
96970773
96971704
96971238
96972171
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
5
Product range
Voltage
Pump type
SL1.80.80.40
SL1.80.80.55
SL1.80.80.75
SL1.100.100.40
SL1.100.100.55
SL1.100.100.75
SL1.100.150.40
SL1.100.150.55
SL1.100.150.75
10
Sensor
Explosion
Poles
proof
Hz
3 x 220-277 V,
DOL
3 x 380-480 V
DOL
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V
Y/D
Stainless
steel impeller
[.A]
[.EX]
[.2]
[.6]
[0F]
[0G]
[1F]
[1G]
[.Q]
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
96973043
96971707
96971241
96972174
96973045
96971715
96971249
96972182
96973048
96971723
96971257
96972190
96973065
96971775
96971309
96972242
96973067
96971783
96971317
96972250
96973069
96971791
96971325
96972258
96973072
96971799
96971333
96972266
96973074
96971807
96971341
96972274
96973076
96971815
96971349
96972282
96970655
96971585
96971120
96972053
96970656
96971586
96971121
96972054
96970657
96971587
96971122
96972055
96970666
96971596
96971131
96972064
96970667
96971597
96971132
96972065
96970668
96971598
96971133
96972066
96970670
96971600
96971135
96972068
96970671
96971601
96971136
96972069
96970672
96971602
96971137
96972070
96970775
96971706
96971240
96972173
96970783
96971714
96971248
96972181
96970791
96971722
96971256
96972189
96970843
96971774
96971308
96972241
96970851
96971782
96971316
96972249
96970859
96971790
96971324
96972257
96970867
96971798
96971332
96972265
96970875
96971806
96971340
96972273
96970883
96971814
96971348
96972281
96970781
96971712
96971246
96972179
96970789
96971720
96971254
96972187
96970658
96971588
96971123
96972056
96970849
96971780
96971314
96972247
96970857
96971788
96971322
96972255
96970669
96971599
96971134
96972067
96970873
96971804
96971338
96972271
96970881
96971812
96971346
96972279
96970673
96971603
96971138
96972071
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
5
Product range
SLV.65.65.22
SLV.65.65.30
SLV.65.65.40
SLV.65.80.22
SLV.65.80.30
SLV.65.80.40
SLV.80.80.11
SLV.80.80.13
SLV.80.80.15
SLV.80.80.22
SLV.80.80.40
SLV.80.80.40
Sensor
Explosion
Poles
proof
Hz
3 x 220-277 V,
DOL
3 x 380-480 V
DOL
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V
Y/D
Stainless
steel impeller
[.A]
[.EX]
[.2]
[.6]
[0F]
[0G]
[1F]
[1G]
[.Q]
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
4
4
4
4
4
4
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
96972931
96971823
96971357
96972290
96972943
96971829
96971363
96972296
96972946
96971837
96971371
96972304
96972948
96971845
96971379
96972312
96972950
96971851
96971385
96972318
96972952
96971859
96971393
96972326
96972954
97639543
96971867
96971401
97639701
96972334
96972956
97639544
96971873
96971407
97639702
96972340
96972958
97639545
96971879
96971413
97639703
96972346
96972960
97639546
96971870
96971404
97639704
96972337
96972962
97639548
96971891
96971425
97639706
96972358
96972964
97639547
96971902
96971436
97639705
96972369
96970674
96971604
96971139
96972072
96970675
96971605
96971140
96972073
96970676
96971606
96971141
96972074
96970677
96971607
96971142
96972075
96970678
96971608
96971143
96972076
96970679
96971609
96971144
96972077
96970680
97639602
96971610
96971145
97639710
96972078
96970681
97639603
96971611
96971146
97639711
96972079
96970682
97639604
96971612
96971147
97639712
96972080
96970683
97639605
96971613
96971148
97639713
96972081
96970684
97639607
96971614
96971149
97639715
96972082
96970685
97639606
96971615
96971150
97639714
96972083
96970891
96971822
96971356
96972289
96970897
96971828
96971362
96972295
96970905
96971836
96971370
96972303
96970913
96971844
96971378
96972311
96970919
96971850
96971384
96972317
96970927
96971858
96971392
96972325
96970954
97639612
96971885
96971419
97639720
96972352
96970957
97639613
96971888
96971422
97639721
96972355
96970968
97639614
96971899
96971433
97639722
96972366
96970945
97639615
96971876
96971410
97639723
96972343
96970959
97639617
96971890
96971424
97639725
96972357
96970967
97639616
96971898
96971432
97639724
96972365
96970894
96971825
96971359
96972292
96970903
96971834
96971368
96972301
96970911
96971842
96971376
96972309
96970916
96971847
96971381
96972314
96970925
96971856
96971390
96972323
96970933
96971864
96971398
96972331
96970938
97639622
96971869
96971403
97639730
96972336
96970944
97639623
96971875
96971409
97639731
96972342
96970950
97639624
96971881
96971415
97639732
96972348
96970951
97639625
96971882
96971416
97639733
96972349
96970965
97639627
96971896
96971430
97639735
96972363
96970973
97639626
96971904
96971438
97639734
96972371
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
11
5
Product range
Voltage
Pump type
SLV.80.80.60
SLV.80.80.75
SLV.80.80.92
SLV.80.80.110
SLV.80.100.11
SLV.80.100.13
SLV.80.100.15
SLV.80.100.22
SLV.80.100.40
SLV.80.100.40
SLV.80.100.60
12
Sensor
Explosion
Poles
proof
Hz
3 x 220-277 V,
DOL
3 x 380-480 V
DOL
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V
Y/D
Stainless
steel impeller
[.A]
[.EX]
[.2]
[.6]
[0F]
[0G]
[1F]
[1G]
[.Q]
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
4
4
4
4
4
4
2
2
2
2
2
2
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
96972966
97639549
96971907
96971441
97639707
96972374
96972968
97639550
96971915
96971449
97639708
96972382
96972971
97639601
96971924
96971457
97639709
96972390
96971000
96970686
97639608
96971616
96971151
97639716
96972084
96970687
97639609
96971617
96971152
97639717
96972085
96970689
97639610
96971619
96971154
97639718
96972087
96972976
97639611
96971621
96971156
97639719
96972089
96970693
97639641
96971623
96971158
97639749
96972091
96970694
97639642
96971624
96971159
97639750
96972092
96970695
97639643
96971625
96971160
97639751
96972093
96970696
97639644
96971626
96971161
97639752
96972094
96970697
97639646
96971627
96971162
97639754
96972095
96970698
97639645
96971628
96971163
97639753
96972096
96970699
97639647
96971629
96971164
97639755
96972097
96970975
97639618
96971906
96971440
97639726
96972373
96970983
97639619
96971914
96971448
97639727
96972381
96970991
97639620
96971923
96971456
97639728
96972389
96972977
97639621
96971931
96971464
97639729
96972397
96971028
97639651
96971960
96971493
97639759
96972426
96971030
97639652
96971962
96971495
97639760
96972428
96971042
97639653
96971974
96971507
97639761
96972440
96971017
97639654
96971949
96971482
97639762
96972415
96971031
97639656
96971963
96971496
97639764
96972429
96971039
97639655
96971971
96971504
97639763
96972437
96971047
97639657
96971979
96971512
97639765
96972445
96970981
97639628
96971912
96971446
97639736
96972379
96970688
97639629
96971618
96971153
97639737
96972086
96970690
97639630
96971620
96971155
97639738
96972088
96970692
97639631
96971622
96971157
97639739
96972090
96971010
97639661
96971942
96971475
97639769
96972408
96971016
97639662
96971948
96971481
97639770
96972414
96971022
97639663
96971954
96971487
97639771
96972420
96971023
97639664
96971955
96971488
97639772
96972421
96971037
97639666
96971969
96971502
97639774
96972435
96971045
97639665
96971977
96971510
97639773
96972443
96971053
97639667
96971985
96971518
97639775
96972451
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
96971932
96971465
96972398
96972979
97639632
96971940
96971473
97639740
96972406
96972981
97639633
96971946
96971479
97639741
96972412
96972983
97639634
96971952
96971485
97639742
96972418
96972987
97639635
96971943
96971476
97639743
96972409
96972989
97639637
96971964
96971497
97639745
96972430
96972991
97639636
96971967
96971500
97639744
96972433
96973003
97639638
96971980
96971513
97639746
96972446
Product range
5
Voltage
Pump type
SLV.80.100.75
SLV.80.100.92
SLV.80.100.110
SLV.100.100.30
SLV.100.100.40
SLV.100.100.55
SLV.100.100.75
Sensor
Explosion
Poles
proof
Hz
3 x 220-277 V,
DOL
3 x 380-480 V
DOL
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V
Y/D
Stainless
steel impeller
[.A]
[.EX]
[.2]
[.6]
[0F]
[0G]
[1F]
[1G]
[.Q]
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
96973005
97639639
96971988
96971521
97639747
96972455
96973009
97639640
96971996
96971529
97639748
96972464
96971072
96970700
97639648
96971630
96971165
97639756
96972098
96970702
97639649
96971632
96971167
97639757
96972100
96973012
97639650
96971634
96971169
97639758
96972102
96970706
97639675
96971636
96971171
97639783
96972104
96970707
97639676
96971637
96971172
97639784
96972105
96970708
97639677
96971638
96971173
97639785
96972106
96970709
97639678
96971639
96971174
97639786
96972107
96971055
97639658
96971987
96971520
97639766
96972454
96971063
97639659
96971995
96971528
97639767
96972463
96973013
97639660
96972003
96971536
97639768
96972471
96971079
97639679
96972011
96971544
97639787
96972479
96971087
97639680
96972019
97622858
97639788
96972487
96971095
97639681
96972027
96971560
97639789
96972495
96971103
97639682
96972035
96971568
97639790
96972503
96970701
97639668
96971631
96971166
97639776
96972099
96970703
97639669
96971633
96971168
97639777
96972101
96970705
97639670
96971635
96971170
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
96972004
96971537
96972472
96973015
97639671
96972012
96971545
97639779
96972480
96973017
97639672
96972020
96971503
97639780
96972488
96973020
97639673
96972028
96971561
97639781
96972496
96973022
97639674
96972036
96971569
97639782
96972504
96972103
96971085
97639683
96972017
96971550
97639791
96972485
96971093
97639684
96972025
96971558
97639792
96972493
96971101
97639685
96972033
96971566
97639793
96972501
96970710
97639686
96971640
96971175
97639794
96972108
13
6
Variants
6. Variants
List of variants
Motor
15 m
20 m
Various cable lengths
25 m
30 m
40 m
50 m
10 m
15 m
20 m
25 m
30 m
40 m
50 m
Tests
Test at specified duty on standard impeller curve
Trimmed impeller for specified duty test
Additional test of entire QH curve (including report)
String test
Contact Grundfos
Witness test
Contact Grundfos
Certificates
Atex aproved pump report
Pump certificate
Insepction certificate
Contact Grundfos
Miscellaneous
Solution
Customer benefits
Resistant to acids
Resistant to mineral oils and vegetable oils
Resistant to most solvents (toluene, petrol,
trichloroethylene, etc.)
Contact Grundfos
Resistant to acids
Resistant to most oils
Resistant to most solvents, etc.
Contact Grundfos
Contact Grundfos
Contact Grundfos
14
Contact Grundfos
Top coating (black RAL9005, red RAL 3000 and other colours)
Contact Grundfos
Special packaging
Contact Grundfos
Special nameplate
Contact Grundfos
Other variants
Contact Grundfos
7
Construction
7. Construction
SL1
Fig. 4
15
Construction
Fig. 5
16
Construction
Fig. 6
17
TM047077 1610
Construction
Fig. 7
18
Construction
Fig. 8
19
Construction
Fig. 9
20
Construction
SLV
21
Construction
Fig. 11 Sectional drawing, SLV pumps without sensor
22
Construction
23
Construction
Fig. 13 Sectional drawing, SLV pumps EX version (Sensor version)
24
Construction
25
Construction
Fig. 15 Exploded view, SLV pumps with sensor
26
Pos.
Component
Material
DIN W.-Nr. /
EN standard
AISI / ASTM
6a
Tubular pin, D8 x 22 A2
Stainless steel
1.4301
304
7a
Stainless steel
1.4301
304
1.4301
304
37
O-ring
NBR rubber
37a
O-ring
NBR rubber
46
48
Stator package
SuperVortex impeller
EN-JL 1030
ASTM A48
Class 200B
Single-channel impeller
EN-JL 1030
ASTM A48
Class 250B
Stainless steel
49
49c
1.4301
304
50
Pump housing
EN-JL 1030
ASTM A48
Class 200B
55
Stator housing
EN-JL 1030
ASTM A48
Class 200B
58
EN-JL 1030
ASTM A48
Class 200B
59
Bearing cover
EN-JL 1040
ASTM A48
Class 250B
76
Nameplate
Stainless steel
1.4401
316
92
Clamp
Stainless steel
1.4401
316
102
Circlip
105
EN-JL1040
ASTM A48
Class 250B
1.0570 1.4401
316
106
107
NBR rubber
109
NBR rubber
NBR rubber
150a
153
Bearing, D-end
Stainless steel
153b
O-ring
NBR rubber
154
Bearing, N-end
Stainless steel
155
Oil chamber
157
Stainless steel
158
Stainless steel
172
174
Stainless steel
174a
Stainless steel
176
181
7G2.5 + 3 x 1
182
Screw
Stainless steel
1.4436
316
186
Screw
Stainless steel
1.4436
316
188
Screw
Stainless steel
1.4436
316
190
Lifting handle
Stainless steel
1.4308
CF8
193
Plug
Stainless steel
1.4436
316
194
Gasket
1.4310
301
198
O-ring
520
521
522
Construction
NBR rubber
Stainless steel
27
7
Construction
Material
DIN W.-Nr. /
EN standard
AISI / ASTM
6a
Tubular pin, D8 x 22 A2
Stainless steel
1.4301
304
7a
Stainless steel
1.4301
304
37
O-ring
NBR rubber
37a
O-ring
NBR rubber
46
1.4301
304
48
Stator package
Stainless steel
1.4408
316/351
CF8M
49
28
Component
SuperVortex impeller
Single-channel impeller
49c
Stainless steel
EN-JL 1030
50
Pump housing
EN-JL 1030
55
Stator housing
EN-JL 1030
58
EN-JL 1030
59
Bearing cover
EN-JL 1040
76
Nameplate
Stainless steel
1.4401
316
92
Clamp
Stainless steel
1.4401
316
102
Circlip
105
1.4301
304
106
107
NBR rubber
NBR rubber
109
NBR rubber
150a
153
Bearing, D-end
Stainless steel
153b
O-ring
NBR rubber
154
Bearing, N-end
Stainless steel
155
Oil chamber
157
Stainless steel
158
Stainless steel
172
174
Stainless steel
174a
Stainless steel
176
EN-JL1040
1.0570 1.4401
316
181
7G2.5 + 3 x 1
182
Screw
Stainless steel
1.4436
316
186
Screw
Stainless steel
1.4436
316
188
Screw
Stainless steel
1.4436
316
190
Lifting handle
Stainless steel
1.4308
CF8
193
Plug
Stainless steel
1.4436
316
194
Gasket
1.4310
301
198
O-ring
520
521
522
NBR rubber
Stainless steel
Features
Product description
8. Product description
Power cables
Standard cable
Ball bearings
The bearings are greased for life.
Main bearings:
Outer cable
diameter
[mm]
7 G AWG 16
4 G AWG 14 + 3 G 16 AWG
7 G AWG 14 + 3 G 16 AWG
13.3
16.2
20.6
Bending radius
Fixed
Free
31.8
31.8
38.1
47.6
47.6
57.2
EMC cable
Shaft seal
Cable type [mm2]
4 G AWG 14 + 3 G 16 AWG
screened cable
Outer cable
diameter
[mm]
17.7
Bending radius
Fixed
Free
38.1
57.2
Surface treatment
29
Product description
Sensors
30
moisture in motor.
Operating conditions
The SL1 and SLV pumps are only for submerged
installation.
Pump
type
Material
variant
SL1/SLV
Standard
6.5 to 14 1)
SLV
6 to 14 1)
1)
Material
Product description
Pumped liquids
pH value
Liquid temperature: 0 C to + 40 C.
When pumping liquids with a density and/or a
kinematic viscosity higher than that of water, use
motors with correspondingly higher outputs.
S1 operation
S3 operation
Motor range
TM02 7776 4003
Operation
Stop
t
Operation
No. of poles
1.1
1.3
1.5
2.2
3
4
6
7.5
9.2
11
2/4
2/4
2/4
2/4
2/4
2/4
2
2/4
2
2
Max.
4 min.
4 min
Stop
6 min
Min.
6 min.
10
10 min.
min
31
8
Product description
Pump controllers
The pumps must be connected to a control box with a
motor protection relay with IEC trip class 10 or 15.
Additional features
Insulation resistance alarm
moisture-in-motor alarm.
These features are directly related to the actual system
configuration and the modules installed.
Communication features
Complete overview of the pump installation
setpoint setting, resetting of system and start/stop
of pumps
access to complete alarm/warning log
foam draining
PC-Tool support
anti-seizing
32
8
Product description
Approvals
The SL1 and SLV pumps have been approved by CSA
and FM, and the explosion-proof versions hold an FM
type examination certificate no.: 3035318
Approval standards
These pumps are approved by CSA and FM according
to UL778, C22.2 no 108 and FM 3600, FM3615 and
FM3615.80.
Explanation to FM approval
The SL1 and SLV pumps have the following explosion
protection classification: Class I, Division 1, Groups C
and D, T4, T3, IP68.
Standards
FM3600
FM3615
FM3615.80
Code
Description
Class I
Division 1
= Area classification
Groups C
and D
= Classification of gases
T4/T3
IP68
= IEC 60529.
33
Standard version
Thermal switches
CSA approved
Ex. version
Thermal switch and moisture switch
CSA and FM approved
Sensor version
Thermal switch and PT1000 resistor
Moisture switch and water-in-oil sensor
CSA approved, with/without FM approval
Product description
Wiring diagrams
Standard version
Thermal switches
CSA approved
Ex. version
Thermal switch and moisture switch
CSA and FM approved
34
Sensor version
Thermal switch and PT1000 resistor
Moisture switch and water-in-oil sensor
CSA approved, with/without FM approval
Standard version
Thermal switches
CSA approved
Ex. version
Thermal switch and moisture switch
CSA and FM approved
Sensor version
Thermal switch and PT1000 resistor
Moisture switch and water-in-oil sensor
CSA approved, with/without FM approval
Product description
Standard version
Thermal switches
CSA approved
Ex. version
Thermal switch and moisture switch
CSA and FM approved
Sensor version
Thermal switch and PT1000 resistor
Moisture switch and water-in-oil sensor
CSA approved, with/without FM approval
35
9
Curve charts and technical data
36
40
Performance curves
SL1.50.65.22
42
Performance curves
SL1.80.100.30
Performance curves
SL1.50.65.30
70
44
Performance curves
SL1.50.65.40
46
Page
Pump curves
98
Performance curves
SLV.65.80.40
128
Performance curves
SLV.80.100.40 - 4-pole
Performance curves
SL1.80.100.40
100
Performance curves
SLV.80.80.11
130
Performance curves
SLV.80.100.40 - 2-pole
72
Performance curves
SL1.80.100.55
102
Performance curves
SLV.80.80.13
132
Performance curves
SLV.80.100.60
Performance curves
SL1.50.80.22
74
Performance curves
SL1.80.100.75
104
Performance curves
SLV.80.80.15
134
Performance curves
SLV.80.100.75
48
Performance curves
SL1.50.80.30
76
Performance curves
SL1.100.100.40
106
Performance curves
SLV.80.80.22
136
Performance curves
SLV.80.100.92
50
Performance curves
SL1.50.80.40
78
Performance curves
SL1.100.100.55
108
Performance curves
SLV.80.80.40 - 4-pole
138
Performance curves
SLV.80.100.110
52
Performance curves
SL1.80.80.15
80
Performance curves
SL1.100.100.75
110
Performance curves
SLV.80.80.40 - 2-pole
140
Performance curves
SLV.100.100.30
52
Performance curves
SL1.80.80.15
82
Performance curves
SL1.100.150.40
112
Performance curves
SLV.80.80.60
142
Performance curves
SLV.100.100.40
54
Performance curves
SL1.80.80.22
84
Performance curves
SL1.100.150.55
114
Performance curves
SLV.80.80.75
144
Performance curves
SLV.100.100.55
56
Performance curves
SL1.80.80.30
86
Performance curves
SL1.100.150.75
116
Performance curves
SLV.80.80.92
146
Performance curves
SLV.100.100.75
58
Performance curves
SL1.80.80.40
88
Performance curves
SLV.65.65.22
118
Performance curves
SLV.80.80.110
60
Performance curves
SL1.80.80.55
90
Performance curves
SLV.65.65.30
120
Performance curves
SLV.80.100.11
62
Performance curves
SL1.80.80.75
92
Performance curves
SLV.65.65.40
122
Performance curves
SLV.80.100.13
64
Performance curves
SL1.80.100.15
94
Performance curves
SLV.65.80.22
124
Performance curves
SLV.80.100.15
66
Performance curves
SL1.80.100.22
96
Performance curves
SLV.65.80.30
126
Performance curves
SLV.80.100.22
QH curve
H
[m]
20
Pump type
SLV.80.80.40.2.6
QH
60 Hz
ISO 9906 Annex A
18
Eta
[%]
28
16
14
Eta 2
12
24
Eta 1
10
16
12
10
0.0
0.5
6
20
10
30
20
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
5.0
0.5
1.0
1.5
2.0
v [m/s]
P1
4.5
4.0
P2
NPSH
[m]
8 NPSH cuves. When sizing
3.5
3.0
2.5
0
0
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
NPSH
2.0
37
9
Curve charts and technical data
Curve conditions
Performance tests
38
Certificates
Certificates have to be confirmed for every order and
are available on request as follows:
Certificate of compliance with the order
(EN 10204-2.1)
Pump test sheet.
Witness test
It is possible for the customer to witness the testing
procedure according to ISO 9906.
The witness test is not a certificate and will not result in
a written statement from Grundfos. The witness itself is
the only guarantee that everything is carried out as
prescribed in the testing procedure.
If the customer wants to witness the test of pump
performance, this request must be stated on the order.
39
10
Performance curves Technical data
H
[m]
20
QH
SL1.50.65.22.2
60 Hz
ISO 9906 Annex A
18
Eta
[%]
70
16
14
12
Eta 2
10
60
50
Eta 1
40
30
20
10
4
10
20
10
30
12
14
40
16
50
18
Q [l/s]
60
Q [m/h]
v [m/s]
DN 65
DN 80
0.0
P
[kW]
3.5
0.5
1.0
1.5
2.0
2.5
3.0
3.5
3.0
v [m/s]
P1
2.5
P2
2.0
1.5
1.0
4
NPSH
0
0
40
4
10
6
20
2
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
0.5
0.0
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
641
366
171
216
321
69
65
145
4 x M16
65
145
4 x 18
86.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
DN1
ZM
210
95
140
700
513
363
81
1"
740
97
175
266
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
771
339
130
325
270
491
65
18
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
[kW] [kW] poles
SL1.50.65.22.2.60G
3 x 380-480 V Y
3 x 220-277 V D /
SL1.50.65.22.2.61F
380-480 V Y
SL1.50.65.22.2.61G 3 x 380-480 V D
SL1.50.65.22.2.60F 3 x 220-277 V D
2.9
2.2
RPM
3500
Starting
method
DOL
motor [%]
Cos
IN
Istart
[A]
[A]
4.5
1/2
3/4
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm2]
0.0054
22
2.9
2.2
3500
SD
7.8
0.0054
22
2.9
2.9
2.2
2.2
2
2
3500
3500
SD
DOL
4.5
7.8
0.0054
0.0054
22
22
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
41
10
Performance curves Technical data
H
[m]
32
SL1.50.65.30.2
60 Hz
ISO 9906 Annex A
28
Eta
[%]
70
QH
Eta 2
24
20
60
50
Eta 1
16
40
12
30
20
10
4
10
20
10
30
12
14
40
16
50
18
Q [l/s]
60
Q [m/h]
v [m/s]
DN 65
DN 80
0.0
P
[kW]
4.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
3.5
v [m/s]
P1
3.0
P2
2.5
NPSH
[m]
8
2.0
1.5
4
NPSH
0.5
0
0
42
4
10
6
20
8
30
2
10
12
40
14
50
16
60
18
Q [l/s]22
Q [m/h]
1.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
641
366
171
216
321
69
65
145
4 x 16
65
145
4 x 18
89.7
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
Dc1
ZDN1
ZM
210
95
140
700
513
363
81
1"
740
97
175
266
145
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
771
339
130
325
270
491
65
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
SL1.50.65.30.2.61G 3 x 380-480 V D
SL1.50.65.30.2.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SL1.50.65.30.2.60G
3.8
3.0
3510
DOL
6.0
0.00956
35
SL1.50.65.30.2.61F
3.8
3.0
3510
SD
10.4
0.00956
35
3.8
3.8
3.0
3.0
2
2
3510
3510
SD
DOL
0.00956
0.00956
35
35
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
43
10
Performance curves Technical data
H
[m]
32
SL1.50.65.40.2
60 Hz
ISO 9906 Annex A
QH
Eta
[%]
70
28
Eta 2
24
20
60
50
Eta 1
16
40
12
30
20
10
4
10
20
10
30
12
14
40
16
50
18
Q [l/s]
60
Q [m/h]
v [m/s]
DN 65
DN 80
0.0
P
[kW]
5.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
P1
4.5
4.0
P2
NPSH
[m]
10
3.5
3.0
2.5
4
NPSH
1.5
0
0
44
4
10
6
20
2
8
30
10
12
40
14
50
16
60
18
Q [l/s]22
Q [m/h]
2.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
677
407
200
227
379
69
65
145
4 x 16
65
145
4 x 18
115.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
210
95
140
741
554
375
81
1"
774
97
175
266
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
807
341
130
325
270
519
65
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SL1.50.65.40.2.61G 3 x 380-480 V D
SL1.50.65.40.2.60F 3 x 220-277 V D
No of
poles
Starting
RPM
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm2]
SL1.50.65.40.2.60G
4.9
4.0
3530
DOL
7.7
0.01590
58
SL1.50.65.40.2.61F
4.9
4.0
3530
SD
13.3
0.01590
58
4.9
4.9
4.0
4.0
2
2
3530
3530
SD
DOL
0.01590
0.01590
58
58
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
45
10
Performance curves Technical data
SL1.50.80
Performance curves SL1.50.80.22
H
[m]
20
SL1.50.80.22.2
QH
60 Hz
ISO 9906 Annex A
18
Eta
[%]
70
16
14
12
60
Eta 2
10
8
50
40
Eta 1
30
20
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
3.5
0.5
1.0
1.5
2.0
v [m/s]
3.0
P1
2.5
P2
2.0
NPSH
[m]
8
1.5
1.0
4
NPSH
0.0
0
0
46
4
10
6
20
2
8
30
10
12
40
14
50
16
60
18
Q [l/s]22
Q [m/h]
0.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
641
366
171
216
321
69
65
145
4 x 16
80
160
8 x 18
87.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
719
526
376
81
1"
774
133
13
171
345
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
771
339
130
325
270
496
80
18
Electrical data
Voltage
[V]
Pump type
SL1.50.80.22.2.60G
3 x 380-480 V Y
3 x 220-277 V D /
SL1.50.80.22.2.61F
380-480 V Y
SL1.50.80.22.2.61G 3 x 380-480 V D
SL1.50.80.22.2.60F 3 x 220-277 V D
2.9
motor [%]
Cos
[A]
[A]
3/4
1/1
Moment
of inertia
[kgm2]
DOL
4.5
0.90
0.00704
3500
SD
7.8
0.90
0.00704
22
3500
3500
SD
DOL
4.5
7.8
0.90
0.90
0.00704
0.00704
22
22
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
2.2
3500
2.9
2.2
2.9
2.9
2.2
2.2
2
2
IN
Istart
1/2
3/4
1/1
1/2
Breakdown
torque
Mmax [Nm]
22
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
47
10
Performance curves Technical data
H
[m]
32
SL1.50.80.30.2
60 Hz
ISO 9906 Annex A
28
QH
Eta 2
24
20
Eta 1
Eta
[%]
70
60
50
16
40
12
30
20
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
4.0
0.5
1.0
1.5
2.0
v [m/s]
3.5
P1
3.0
P2
2.5
2.0
1.5
0.5
NPSH
0
0
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
1.0
48
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
641
366
171
216
321
69
65
145
4 x 16
80
160
8 x 18
90.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
719
526
376
81
1"
774
131
13
171
345
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
771
339
130
325
270
496
80
18
Electrical data
Voltage
[V]
Pump type
IN
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SL1.50.80.30.2.60G
3 x 380-480 V Y
3 x 220-277 V D /
SL1.50.80.30.2.61F
380-480 V Y
SL1.50.80.30.2.61G 3 x 380-480 V D
SL1.50.80.30.2.60F 3 x 220-277 V D
3.8
3.0
3510
Istart
motor [%]
1/2
3/4
Cos
[A]
[A]
3/4
1/1
DOL
6.0
1/1
1/2
0.87
Moment Breakdown
of inertia
torque
Mmax [Nm]
[kgm2]
0.00956
35
3.8
3.0
3510
SD
10.4
102
0.87
0.00956
35
3.8
3.8
3.0
3.0
2
2
3510
3510
SD
DOL
6.0
10.4
0.00956
0.00956
35
35
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
49
10
Performance curves Technical data
H
[m]
32
SL1.50.80.40.2
60 Hz
ISO 9906 Annex A
QH
28
24
Eta 2
20
Eta 1
Eta
[%]
70
60
50
16
40
12
30
20
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
5.0
0.5
1.0
1.5
2.0
v [m/s]
P1
4.5
4.0
P2
3.5
3.0
2.5
4
NPSH
1.5
0
0
4
10
6
20
2
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
2.0
50
NPSH
[m]
10
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
677
407
200
227
379
69
65
145
4 x 16
80
160
8 x 18
116.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
760
567
387
81
1"
808
131
13
171
345
65
4 x M16
V1
V2
V3
V4
V5
V6
V7
807
341
130
325
270
525
80
18
Electrical data
SL1.50.80.40.2.60G 3 x 380-480 V D
3 x 220-277 V D /
SL1.50.80.40.2.61F
380-480 V Y
SL1.50.80.40.2.61G 3 x 380-480 V D
SL1.50.80.40.2.60F 3 x 220-277 V D
4.9
4.0
3530
motor [%]
Cos
[A]
[A]
1/1
Moment
of inertia
[kgm2]
DOL
7.7
0.01590
58
IN
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
Istart
1/2
3/4
1/1
1/2
3/4
Breakdown
torque
Mmax [Nm]
4.9
4.0
3530
SD
13.3
156
0.01590
58
4.9
4.9
4.0
4.0
2
2
3530
3530
SD
DOL
7.7
13.3
0.01590
0.01590
58
58
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
50
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
51
10
Performance curves Technical data
SL1.80.80
Performance curves SL1.80.80.15
H
[m]
11
SL1.80.80.15.4
60 Hz
ISO 9906 Annex A
QH
10
9
Eta
[%]
70
8
7
6
60
Eta 2
50
Eta 1
40
30
20
10
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
DN 80
v [m/s]
DN 100
4 v [m/s]
2.0
P1
1.5
P2
1.0
0.5
0.0
NPSH
0
0
52
NPSH
[m]
6
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
P
[kW]
2.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
682
435
171
272
347
89
100
180
8 x 16
80
160
8 x 18
96.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
788
595
432
81
1"
790
108
13
171
345
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
364
130
355
300
567
80
19
Electrical data
Voltage
[V]
Pump type
SL1.80.80.15.4.60G
SL1.80.80.15.4.61G
3 x 380-480 V Y
3 x 380-480 V D
3 x 220-277 V D /
SL1.80.80.15.4.61F
380-480 V Y
SL1.80.80.15.4.60F 3 x 220-277 V D
motor [%]
Cos
[A]
[A]
3/4
1/1
Moment
of inertia
[kgm2]
1.9
1.9
1.5
1.5
4
4
1750
1750
DOL
SD
3.5
3.5
0.77
0.77
0.02840
0.02840
30
30
1.9
1.5
1750
SD
6.0
0.77
0.02840
30
1.9
1.5
1750
DOL
6.0
0.77
0.02840
30
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
IN
Istart
1/2
3/4
1/1
1/2
Breakdown
torque
Mmax [Nm]
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
53
10
Performance curves Technical data
H
[m]
16
SL1.80.80.22.4
60 Hz
ISO 9906 Annex A
14
QH
Eta 2
12
Eta
[%]
70
60
Eta 1
10
50
40
30
20
10
20
12
16
40
20
60
24
28
80
32
100
Q [l/s]
120 Q [m/h]
DN 80
7 v [m/s]
DN 100
v [m/s]
2.5
P1
2.0
P2
1.5
1.0
0.5
0.0
NPSH
0
0
54
NPSH
[m]
6
8
20
12
40
16
60
20
24
80
28
100
32
Q [l/s]
120 Q [m/h]
P
[kW]
3.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
682
435
171
272
347
89
100
180
8 x 16
80
160
8 x 18
110
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
788
595
432
81
1"
790
111
13
171
345
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
364
130
355
300
567
80
19
Electrical data
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
SL1.80.80.22.4.60G
3 x 380-480 V Y
3 x 220-277 V D /
SL1.80.80.22.4.61F
380-480 V Y
SL1.80.80.22.4.61G 3 x 380-480 V D
SL1.80.80.22.4.60F 3 x 220-277 V D
IN
Istart
motor [%]
1/2
3/4
Cos
1/1
1/2
Moment Breakdown
of inertia
torque
Mmax [Nm]
[kgm2]
[A]
[A]
3/4
1/1
2.7
2.2
1760
DOL
4.6
0.80
0.04290
42
2.7
2.2
1760
SD
8.0
0.80
0.04290
42
2.7
2.7
2.2
2.2
4
4
1760
1760
SD
DOL
4.6
8.0
0.80
0.80
0.04290
0.04290
42
42
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
55
10
Performance curves Technical data
H
[m]
16
SL1.80.80.30.4
60 Hz
ISO 9906 Annex A
14
QH
Eta
[%]
70
Eta 2
12
60
Eta 1
10
50
40
30
20
10
10
20
40
15
20
60
25
80
30
35
100
120
40
Q [l/s]
140
Q [m/h]
v [m/s]
DN 80
DN 100
P
[kW]
4.0
v [m/s]
P1
3.5
3.0
P2
2.5
2.0
56
NPSH
20
10
40
15
60
20
25
80
30
100
35
120
40
Q [l/s]
140
Q [m/h]
1.5
1.0
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
505
200
319
397
118
100
180
8 x 16
80
160
8 x 18
139.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
858
666
480
81
1"
793
82
13
171
345
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
841
390
130
355
300
623
80
19
Electrical data
SL1.80.80.30.4.60G
3 x 380-480 V Y
3 x 220-277 V D /
SL1.80.80.30.4.61F
380-480 V Y
SL1.80.80.30.4.61G 3 x 380-480 V D
SL1.80.80.30.4.60F 3 x 220-277 V D
motor [%]
Cos
[A]
[A]
1/1
Moment
of inertia
[kgm2]
3.7
3.0
1750
DOL
6.3
0.05690
60
3.7
3.0
1750
DOL
10.9
0.05690
60
3.7
3.7
3.0
3.0
4
4
1750
1750
DOL
DOL
6.3
10.9
0.05690
0.05690
60
60
IN
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
Istart
1/2
3/4
1/1
1/2
3/4
Breakdown
torque
Mmax [Nm]
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
57
10
Performance curves Technical data
H
[m]
20
SL1.80.80.40.4
60 Hz
ISO 9906 Annex A
QH
18
16
14
70
Eta 2
12
Eta
[%]
80
60
Eta 1
10
50
40
30
20
10
10
20
40
15
20
60
25
80
30
35
40
45
Q [l/s]
DN 80
v [m/s]
DN 100
6 v [m/s]
4.5
P1
4.0
P2
NPSH
[m]
6
3.5
3.0
2.5
2.0
1.5
58
NPSH
20
10
40
15
60
20
25
80
30
35
40
45
Q [l/s]
P
[kW]
5.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
748
505
200
319
397
118
100
180
8 x 16
80
160
8 x 18
144.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
858
666
480
81
1"
830
82
13
171
345
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
878
390
130
355
300
623
80
19
Electrical data
Voltage
[V]
Pump type
SL1.80.80.40.4.60G
SL1.80.80.40.4.61F
SL1.80.80.40.4.61G
SL1.80.80.40.4.60F
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
motor [%]
Cos
[A]
[A]
1/1
Moment
of inertia
[kgm2]
4.9
4.0
1760
DOL
8.6
0.07300
89
4.9
4.0
1760
DOL
14.9
0.07300
89
4.9
4.9
4.0
4.0
4
4
1760
1760
DOL
DOL
8.6
14.9
0.07300
0.07300
89
89
IN
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
Istart
1/2
3/4
1/1
1/2
3/4
Breakdown
torque
Mmax [Nm]
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
59
10
Performance curves Technical data
H
[m]
22
QH
SL1.80.80.55.4
60 Hz
ISO 9906 Annex A
20
Eta
[%]
80
18
16
14
70
Eta 2
12
60
Eta 1
10
50
40
30
20
10
10 15 20 25 30 35 40 45 50
20
40
60
Q [l/s]
DN 80
10 v [m/s]
DN 100
v [m/s]
P1
P2
5
4
3
2
1
60
NPSH
[m]
6
2
NPSH
20
10 15 20 25 30 35 40 45 50
40
60
Q [l/s]
P
[kW]
7
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
755
505
200
319
397
118
100
180
8 x 16
80
160
8 x 18
150.9
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
858
666
480
81
1"
837
82
13
171
345
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
885
390
130
355
300
623
80
19
Electrical data
SL1.80.80.55.4.60G 3 x 380-480 V D
3 x 220-277 V D /
SL1.80.80.55.4.61F
380-480 V Y
SL1.80.80.55.4.61G 3 x 380-480 V D
SL1.80.80.55.4.60F 3 x 220-277 V D
motor [%]
Cos
3/4
1/1
Moment
of inertia
[kgm2]
6.4
5.5
1760
DOL
10.4
0.85
0.10056
98
6.4
5.5
1760
DOL
18.0
131
0.85
0.10056
98
6.4
6.4
5.5
5.5
4
4
1760
1760
DOL
DOL
10.4
18.0
0.85
0.85
0.10056
0.10056
98
98
IN
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
[A]
Istart
[A]
1/2
3/4
1/1
1/2
Breakdown
torque
Mmax [Nm]
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
61
10
Performance curves Technical data
H
[m]
32
SL1.80.80.75.4
60 Hz
ISO 9906 Annex A
28
QH
Eta 2
24
Eta
[%]
70
60
Eta 1
20
50
16
40
12
30
20
10
10 15 20 25 30 35 40 45 50 55 Q [l/s]
20
40
60
Q [m/h]
DN 80
10 11 v [m/s]
DN 100
7 v [m/s]
P1
P2
6
5
4
3
62
NPSH
[m]
6
2
NPSH
20
10 15 20 25 30 35 40 45 50 55 Q [l/s]
40
60
Q [m/h]
P
[kW]
9
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
818
530
217
328
423
115
100
180
8 x 16
80
160
8 x 18
197.7
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
Dc1
DN1
ZM
220
95
160
883
690
489
81
1"
900
85
13
171
345
180
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
948
390
130
355
300
648
80
19
Electrical data
Voltage
[V]
Pump type
SL1.80.80.75.4.60G
SL1.80.80.75.4.61G
3 x 380-480 V D
3 x 380-480 V D
3 x 220-277 V D /
SL1.80.80.75.4.61F
380-480 V Y
SL1.80.80.75.4.60F 3 x 220-277 V D
8.6
8.6
motor [%]
Cos
Moment Breakdown
of inertia
torque
Mmax [Nm]
[kgm 2]
IN
Istart
[A]
[A]
1/2
DOL
SD
13.6
13.6
104
104
0.13400
0.13400
135
135
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3/4
1/1
1/2
3/4
1/1
7.5
7.5
4
4
1760
1760
8.6
7.5
1760
SD
23.6
179
0.13400
135
8.6
7.5
1760
DOL
23.6
179
0.13400
135
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
63
10
Performance curves Technical data
SL1.80.100
Performance curves SL1.80.100.15
H
[m]
11
SL1.80.100.15.4
60 Hz
ISO 9906 Annex A
QH
10
9
Eta
[%]
70
8
7
Eta 2
6
5
60
50
Eta 1
40
30
20
10
8
20
12
40
16
20
60
24
80
28
32
100
Q [l/s]
120 Q [m/h]
DN 100
v [m/s]
DN 150
0.0
P
[kW]
2.5
0.5
1.0
1.5
v [m/s]
2.0
P1
1.5
P2
1.0
0.0
0
0
64
NPSH
8
20
12
40
16
60
20
24
80
28
100
32
Q [l/s]40
120 Q [m/h]
0.5
NPSH
[m]
4
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
682
435
171
272
347
90
100
180
8 x 16
100
180
8 x 18
97.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
878
652
489
110
830
150
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
369
130
355
300
591
100
19
Electrical data
SL1.80.100.15.4.60G 3 x 380-480 V Y
3 x 220-277 V D /
SL1.80.100.15.4.61F
380-480 V Y
SL1.80.100.15.4.61G 3 x 380-480 V D
SL1.80.100.15.4.60F 3 x 220-277 V D
motor [%]
Cos
1/1
Moment
of inertia
[kgm2]
1.9
1.5
1750
DOL
0.02840
30
1.9
1.5
1750
SD
0.02840
30
1.9
1.9
1.5
1.5
4
4
1750
1750
SD
DOL
0.02840
0.02840
30
30
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
IN
Istart
[A]
[A]
1/2
3/4
1/1
1/2
3/4
Breakdown
torque
Mmax [Nm]
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
65
10
Performance curves Technical data
H
[m]
16
SL1.80.100.22.4
60 Hz
ISO 9906 Annex A
14
Eta
[%]
70
Eta 2
QH
12
60
Eta 1
10
50
40
30
20
10
8
20
12
40
16
20
60
24
80
28
32
100
36
120
Q [l/s]
Q [m/h]
DN 100
5v [m/s]
DN 150
0.0
P
[kW]
3.0
0.5
1.0
1.5
2.0
v [m/s]
2.5
P1
2.0
P2
NPSH
[m]
4
1.5
1.0
0.0
0
0
66
NPSH
8
20
12
40
16
60
20
24
80
28
100
32
120
36
Q [l/s]44
Q [m/h]
0.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
682
435
171
272
347
90
100
180
8 x 16
100
180
8 x 18
111
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
878
652
489
110
2"
830
150
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
369
130
355
300
591
100
19
Electrical data
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
SL1.80.100.22.4.61F
SL1.80.100.22.4.60G
SL1.80.100.22.4.61G
SL1.80.100.22.4.60F
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment Breakdown
of inertia
torque
Mmax [Nm]
[kgm2]
2.7
2.2
1760
SD
0.0429
42
2.7
2.7
2.7
2.2
2.2
2.2
4
4
4
1760
1760
1760
DOL
SD
DOL
0.0429
0.0429
0.0429
42
42
42
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
67
10
Performance curves Technical data
H
[m]
16
SL1.80.100.30.4
60 Hz
ISO 9906 Annex A
14
Eta 2
QH
12
Eta
[%]
70
60
Eta 1
10
50
40
30
20
10
20
10
40
15
20
60
25
80
30
35
100
120
40
Q [l/s]
140
Q [m/h]
v [m/s]
DN 100
DN 150
0.0
P
[kW]
4.0
0.5
1.0
1.5
2.0
v [m/s]
P1
3.5
3.0
P2
NPSH
[m]
4
2.5
2.0
1.0
68
NPSH
20
10
40
15
60
20
25
80
30
100
35
120
40
Q [l/s]
140
Q [m/h]
1.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
726
505
200
319
397
115
100
180
8 x 16
100
180
8 x 18
140.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
948
722
536
110
2"
830
125
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
856
395
130
355
300
647
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SL1.80.100.30.4.60G 3 x 380-480 V Y
3 x 220-277 V D /
SL1.80.100.30.4.61F
380-480 V Y
SL1.80.100.30.4.61G 3 x 380-480 V D
SL1.80.100.30.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
Moment Breakdown
of inertia
torque
Mmax [Nm]
1/1
[kgm2]
3.7
3.0
1750
DOL
6.3
0.05690
60
3.7
3.0
1750
DOL
0.05690
60
3.7
3.7
3.0
3.0
4
4
1750
1750
DOL
DOL
0.05690
0.05690
60
60
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
69
10
Performance curves Technical data
H
[m]
20
SL1.80.100.40.4
60 Hz
ISO 9906 Annex A
QH
18
16
Eta 2
14
Eta
[%]
80
70
Eta 1
12
60
10
50
40
30
20
10
20
10 15 20 25 30 35 40 45 50
40
60
Q [l/s]
DN 100
v [m/s]
DN 150
0.0
P
[kW]
5
0.5
1.0
1.5
2.0
2.5
v [m/s]
P1
P2
NPSH
[m]
4
70
NPSH
20
10 15 20 25 30 35 40 45 50
40
60
Q [l/s]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
748
505
200
319
397
115
100
180
8 x 16
100
180
8 x 18
145.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
948
722
536
110
2"
870
125
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
878
395
130
355
300
647
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SL1.80.100.40.4.60G 3 x 380-480 V D
3 x 220-277 V D /
SL1.80.100.40.4.61F
380-480 V Y
SL1.80.100.40.4.61G 3 x 380-480 V D
SL1.80.100.40.4.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
Moment Breakdown
of inertia
torque
Mmax [Nm]
1/1
[kgm 2]
[A]
[A]
4.9
4.0
1760
DOL
8.6
0.07300
89
4.9
4.0
1760
DOL
0.07300
89
4.9
4.9
4.0
4.0
4
4
1760
1760
DOL
DOL
0.07300
0.07300
89
89
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
71
10
Performance curves Technical data
H
[m]
22
QH
SL1.80.100.55.4
60 Hz
ISO 9906 Annex A
20
18
Eta
[%]
70
16
14
Eta 2
12
60
Eta 1
10
50
40
30
20
10
20
10 15 20 25 30 35 40 45 50 55 Q [l/s]
40
60
Q [m/h]
DN 100
7 v [m/s]
DN 150
0.0
P
[kW]
7
0.5
1.0
1.5
2.0
2.5
3.0
v [m/s]
P1
P2
NPSH
[m]
4
4
3
1
72
NPSH
20
10 15 20 25 30 35 40 45 50 55 Q [l/s]
40
60
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
755
505
200
319
397
115
100
180
8 x 16
100
180
8 x 18
121.9
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
948
722
536
110
2"
870
125
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
885
395
130
355
300
647
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SL1.80.100.55.4.60G
3 x 380-480 V D
3 x 220-277 V D /
SL1.80.100.55.4.61F
380-480 V Y
SL1.80.100.55.4.61G 3 x 380-480 V D
SL1.80.100.55.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment Breakdown
of inertia
torque
[kgm2] Mmax [Nm]
6.4
5.5
1760
DOL
0.10056
98
6.4
5.5
1760
DOL
18.0
0.10056
98
6.4
6.4
5.5
5.5
4
4
1760
1760
DOL
DOL
0.10056
0.10056
98
98
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
73
10
Performance curves Technical data
H
[m]
32
SL1.80.100.75.4
60 Hz
ISO 9906 Annex A
Eta 2
28
QH
Eta 1
24
Eta
[%]
70
60
20
50
16
40
12
30
20
10
5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]
Q [m/h]
DN 100
v [m/s]
DN 150
0.0
P
[kW]
9
0.5
1.0
1.5
2.0
2.5
3.0
v [m/s]
P1
P2
NPSH
[m]
4
6
5
3
74
NPSH
5 10 15 20 25 30 35 40 45 50 55 60 Q [l/s]
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
818
530
217
328
423
116
100
180
8 x 16
100
180
8 x 18
198.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
972
747
545
110
2"
940
124
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
948
395
130
355
300
672
100
19
Electrical data
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
SL1.80.100.75.4.60G
SL1.80.100.75.4.61G
SL1.80.100.75.4.61F
SL1.80.100.75.4.60F
3 x 380-480 V D
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 220-277 V D
8.6
8.6
7.5
7.5
4
4
1760
1760
IN
Istart
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment Breakdown
of inertia
torque
[kgm2] Mmax [Nm]
[A]
[A]
DOL
SD
13.6
13.6
0.13400
0.13400
135
135
8.6
7.5
1760
SD
23.6
0.13400
135
8.6
7.5
1760
DOL
23.6
0.13400
135
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
75
10
Performance curves Technical data
SL1.100.100
Performance curves SL1.100.100.40
H
[m]
16
SL1.100.100.40.4
60 Hz
ISO 9906 Annex A
14
QH
Eta
[%]
70
12
Eta 2
60
10
Eta 1
50
40
30
20
10
20
10 15 20 25 30 35 40 45 50 55 Q [l/s]
40
60
Q [m/h]
DN 100
7 v [m/s]
DN 150
0.0
P
[kW]
5
0.5
1.0
1.5
2.0
2.5
3.0
v [m/s]
P1
P2
3
2
76
NPSH
20
10 15 20 25 30 35 40 45 50 55 Q [l/s]
40
60
Q [m/h]
1
0
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
755
541
200
320
438
115
150
240
8 x 20
100
180
8 x 18
158.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
983
758
537
110
2"
879
125
220
413
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
941
445
186
450
400
711
100
22
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SL1.100.100.40.4.60G 3 x 380-480 V D
3 x 220-277 V D /
SL1.100.100.40.4.61F
380-480 V Y
SL1.100.100.40.4.61G 3 x 380-480 V D
SL1.100.100.40.4.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment Breakdown
of inertia
torque
[kgm 2] Mmax [Nm]
[A]
[A]
4.9
4.0
1760
DOL
8.6
0.09200
4.9
4.0
1760
DOL
0.09200
89
4.9
4.9
4.0
4.0
4
4
1760
1760
DOL
DOL
0.09200
0.09200
89
89
89
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
77
10
Performance curves Technical data
H
[m]
16
SL1.100.100.55.4
60 Hz
ISO 9906 Annex A
QH
14
Eta 2
12
Eta
[%]
70
60
Eta 1
10
50
40
30
20
10
10
20
30
50
40
100
50
150
60
70 Q [l/s]
200
Q [m/h]
DN 100
0.5
1.0
9 v [m/s]
3.0
3.5
v [m/s]
DN 150
0.0
P
[kW]
7
1.5
2.0
2.5
P1
P2
NPSH
[m]
6
4
3
0
0
78
NPSH
10
20
50
30
100
40
150
50
60
200
70 Q [l/s]
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
762
541
200
320
438
115
150
240
8 x M20
100
180
8 x 18
165.3
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
983
758
537
110
2.0
886
125
220
413
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
948
445
186
450
400
711
100
22
Electrical data
Voltage
[V]
Pump type
SL1.100.100.55.4.60G 3 x 380-480 V D
3 x 220-277 V D /
SL1.100.100.55.4.61F
380-480 V Y
SL1.100.100.55.4.61G 3 x 380-480 V D
SL1.100.100.55.4.60F 3 x 220-277 V D
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment Breakdown
of inertia
torque
[kgm2] Mmax [Nm]
6.4
5.5
1760
DOL
0.11356
98
6.4
5.5
1760
DOL
0.11356
98
6.4
6.4
5.5
5.5
4
4
1760
1760
DOL
DOL
0.11356
0.11356
98
98
Pump data
Max.
Pump housing
pressure
Impeller type solids size
Single
channel
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
Insulation
class
[m]
20
20
pH
[C]
IP68
40
4-14
79
10
Performance curves Technical data
H
[m]
20
SL1.100.100.75.4
QH
60 Hz
ISO 9906 Annex A
18
16
Eta 2
14
70
Eta 1
12
Eta
[%]
80
60
10
50
40
30
20
10
10
20
30
50
40
100
50
150
60
200
70
80Q [l/s]
250
Q [m/h]
10 v [m/s]
DN 100
0.5
1.0
3.0
3.5
4.0
DN 150
1.5
2.0
2.5
v [m/s]
P1
P2
6
NPSH
0
0
80
NPSH
[m]
10
10
20
50
30
100
40
150
50
60
200
70
80Q [l/s]
250
Q [m/h]
0.0
P
[kW]
9
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
827
541
217
312
462
115
150
240
8 x M20
100
180
8 x 18
204
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
983
758
529
110
951
125
220
413
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
1.013
445
186
450
400
706
100
22
Electrical data
Voltage
[V]
Pump type
SL1.100.100.75.4.60G 3 x 380-480 V D
SL1.100.100.75.4.61G 3 x 380-480 V D
3 x 220-277 V D /
SL1.100.100.75.4.61F
380-480 V Y
SL1.100.100.75.4.60F 3 x 220-277 V D
motor [%]
Cos
IN
Istart
[A]
[A]
DOL
SD
13.6
13.6
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
1/2
3/4
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
8.6
8.6
7.5
7.5
4
4
1760
1760
0.13300
0.13300
135
135
8.6
7.5
1760
SD
23.6
0.13300
135
8.6
7.5
1760
DOL
23.6
0.13300
135
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
81
10
Performance curves Technical data
SL1.100.150
Performance curves SL1.100.150.40
H
[m]
16
SL1.100.150.40.4
60 Hz
ISO 9906 Annex A
14
Eta 2
Eta
[%]
70
QH
12
60
Eta 1
10
50
40
30
20
10
10
20
50
30
40
100
50
150
60 Q [l/s]
200
Q [m/h]
DN 150
0.0
0.5
1.0
1.5
2.0
2.5
3.0
v [m/s]
DN 200
0.0
P
[kW]
5
0.5
1.0
1.5
v [m/s]
P1
P2
3
2
0
0
82
NPSH
10
20
50
30
100
40
150
50
60 Q [l/s]
200
Q [m/h]
1
0
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
755
541
200
320
440
111
150
240
8 x M20
150
240
8 x 22
160.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
300
110
280
1.093
780
559
110
919
164
280
450
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
941
555
186
450
400
807
150
22
Electrical data
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SL1.100.150.40.4.61G 3 x 380-480 V D
SL1.100.150.40.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
1/1
Cos
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SL1.100.150.40.4.60G
4.9
4.0
1760
DOL
8.6
0.09200
89
SL1.100.150.40.4.61F
4.9
4.0
1760
DOL
14.9
0.09200
89
4.9
4.9
4.0
4.0
4
4
1760
1760
DOL
DOL
8.6
14.9
0.09200
0.09200
89
89
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
83
10
Performance curves Technical data
H
[m]
16
SL1.100.150.55.4
60 Hz
ISO 9906 Annex A
QH
14
Eta
[%]
70
12
60
10
Eta 2
Eta 1
50
40
30
20
10
10
20
50
30
40
100
50
150
60
200
70 Q [l/s]
Q [m/h]
DN 150
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
2.0
v [m/s]
DN 200
0.0
P
[kW]
7
0.5
1.0
1.5
P1
P2
4
3
0
0
84
NPSH
10
20
50
30
100
40
150
50
60
200
70 Q [l/s]
Q [m/h]
2
1
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
762
541
200
320
440
111
150
240
8 x M20
150
240
8 x 22
167.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
300
110
280
1.093
780
559
110
926
164
280
450
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
948
555
186
450
400
807
150
22
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SL1.100.150.55.4.61G 3 x 380-480 V D
SL1.100.150.55.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
1/1
Cos
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SL1.100.150.55.4.60G
6.4
5.5
1760
DOL
10.4
0.11356
98
SL1.100.150.55.4.61F
6.4
5.5
1760
DOL
18.0
0.11356
98
6.4
6.4
5.5
5.5
4
4
1760
1760
DOL
DOL
10.4
18.0
0.11356
0.11356
98
98
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
85
10
Performance curves Technical data
H
[m]
20
SL1.100.150.75.4
60 Hz
ISO 9906 Annex A
QH
18
16
Eta 2
14
70
Eta 1
12
Eta
[%]
80
60
10
50
40
30
20
10
10
20
50
30
40
100
50
150
60
200
70
80Q [l/s]
250
Q [m/h]
4.0
v [m/s]
DN 150
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
DN 200
0.0
P
[kW]
9
0.5
1.0
1.5
2.0
2.5 v [m/s]
P1
P2
NPSH
[m]
12
10
0
0
86
10
20
50
30
100
40
150
50
60
200
70
80Q [l/s]
250
Q [m/h]
NPSH
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
827
541
217
306
472
111
150
240
8 x M20
150
240
8 x 22
206.1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
300
110
280
1.093
780
559
110
991
164
280
450
150
4 x M16
V1
V2
V3
V4
V5
V6
V7
1.013
555
186
450
400
803
150
22
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SL1.100.150.75.4.60G 3 x 380-480 V D
SL1.100.150.75.4.61G 3 x 380-480 V D
3 x 220-277 V D /
SL1.100.150.75.4.61F
380-480 V Y
SL1.100.150.75.4.60F 3 x 220-277 V D
8.6
8.6
7.5
7.5
No of
poles
RPM
4
4
1760
1760
Starting
method
DOL
SD
motor [%]
Cos
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
IN
Istart
[A]
[A]
13.6
13.6
0.133
0.133
135
135
1/2
3/4
1/1
1/2
3/4
1/1
8.6
7.5
1760
SD
23.6
0.133
135
8.6
7.5
1760
DOL
23.6
0.133
135
Pump data
Impeller type
Single channel
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
87
10
Performance curves Technical data
SLV.65.65
Performance curves SLV.65.65.22
H
[m]
20
SLV.65.65.22.2.6
60 Hz
ISO 9906 Annex A
QH
18
16
Eta 2
14
Eta
[%]
32
28
12
24
Eta 1
10
20
16
12
4
10
20
10
30
12
40
14
16Q [l/s]
50
Q [m/h]
DN 65
v [m/s]
DN 80
0.0
P
[kW]
3.5
0.5
1.0
1.5
2.0
2.5
3.0 v [m/s]
3.0
P1
P2
NPSH
[m]
6
2.0
1.5
NPSH
1.0
0.5
0.0
0
0
88
4
10
6
20
8
30
10
12
40
14
16Q [l/s]
50
Q [m/h]
2.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
684
396
171
246
321
102
80
160
8 x M16
65
145
4 x 18
86.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
210
95
140
730
543
394
81
1.5
747
64
175
266
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
372
128
330
280
524
65
18
Electrical data
Voltage
[V]
Pump type
SLV.65.65.22.2.60G
SLV.65.65.22.2.61F
SLV.65.65.22.2.61G
SLV.65.65.22.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
2.9
2.2
3500
DOL
4.5
0.00540
22
2.9
2.2
3500
SD
7.8
0.00540
22
2.9
2.9
2.2
2.2
2
2
3500
3500
SD
DOL
4.5
7.8
0.00540
0.00540
22
22
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
89
10
Performance curves Technical data
H
[m]
22
SLV.65.65.30.2.6
60 Hz
ISO 9906 Annex A
QH
18
Eta
[%]
36
16
32
14
28
12
24
10
20
16
20
12
Eta 2
Eta 1
10
20
10
30
12
14
40
16
50
Q [l/s]
60 Q [m/h]
DN 65
v [m/s]
DN 80
0.0
P
[kW]
4.0
0.5
1.0
1.5
2.0
2.5
3.0
v [m/s]
3.5
P1
3.0
P2
2.5
2.0
1.5
0
0
90
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
Q [l/s]
60 Q [m/h]
1.0
0.5
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
684
396
171
246
321
102
80
160
8 x M16
65
145
4 x 18
89.50
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
210
95
140
730
543
394
81
1.5
747
64
175
266
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
372
128
330
280
524
65
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SLV.65.65.30.2.60G
3 x 380-480 V Y
3 x 220-277 V D /
SLV.65.65.30.2.61F
380-480 V Y
SLV.65.65.30.2.61G 3 x 380-480 V D
SLV.65.65.30.2.60F 3 x 220-277 V D
3.8
3.0
No of
poles
RPM
3510
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm 2]
DOL
6.0
0.87
10.4
0.87
0.00670
35
0.00670
0.00670
35
35
3.8
3.0
3510
SD
3.8
3.8
3.0
3.0
2
2
3510
3510
SD
DOL
0.00670
35
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
91
10
Performance curves Technical data
H
[m]
32
SLV.65.65.40.2.6
60 Hz
ISO 9906 Annex A
QH
28
Eta 2
24
20
Eta
[%]
40
35
30
Eta 1
16
25
12
20
15
10
4
10
20
10
30
12 Q [l/s]
40
Q [m/h]
DN 65
v [m/s]
2.0
v [m/s]
DN 80
0.0
P
[kW]
5.0
0.5
1.0
1.5
P1
4.5
4.0
P2
3.5
3.0
0
0
92
NPSH
4
10
6
20
8
30
10
12 Q [l/s]
40
Q [m/h]
2.5
2.0
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
718
456
200
276
380
106
80
160
8 x M16
65
145
4 x 18
116.7
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
210
95
140
790
604
424
81
1.5
778
60
175
266
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
846
376
128
330
280
568
65
18
Electrical data
Voltage
[V]
Pump type
SLV.65.65.40.2.60G
SLV.65.65.40.2.61F
SLV.65.65.40.2.61G
SLV.65.65.40.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
Starting
RPM
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
4.9
4.0
3530
DOL
7.7
0.88
0.01590
58
4.9
4.0
3530
SD
13.3
0.88
0.01590
58
4.9
4.9
4.0
4.0
2
2
3530
3530
SD
DOL
7.7
13.3
0.88
0.88
0.01590
0.01590
58
58
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
93
10
Performance curves Technical data
SLV.65.80
Performance curves SLV.65.80.22
H
[m]
18
SLV.65.80.22.2.6
60 Hz
ISO 9906 Annex A
QH
16
14
Eta 2
12
Eta
[%]
35
30
10
25
Eta 1
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
Q [l/s]
60 Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
v [m/s]
DN 100
0.0
P
[kW]
3.5
0.5
1.0
1.5
2.0
v [m/s]
3.0
P1
2.5
P2
2.0
1.5
1.0
0.0
NPSH
0
0
4
10
6
20
8
30
10
12
40
14
50
16
Q [l/s]
60 Q [m/h]
0.5
94
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
685
397
171
247
321
103
80
160
8 x M16
80
160
8 x 18
87.50
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
750
557
408
81
1.5
782
97
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
813
373
128
330
280
530
80
18
Electrical data
Voltage
[V]
Pump type
SLV.65.80.22.2.60G
SLV.65.80.22.2.61F
SLV.65.80.22.2.61G
SLV.65.80.22.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
2.9
2.2
3500
DOL
4.5
0.90
0.00540
22
2.9
2.2
3500
SD
7.8
0.90
0.00540
22
2.9
2.9
2.2
2.2
2
2
3500
3500
SD
DOL
4.5
7.8
0.90
0.90
0.00540
0.00540
22
22
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
95
10
Performance curves Technical data
H
[m]
22
SLV.65.80.30.2.6
60 Hz
ISO 9906 Annex A
QH
20
18
16
Eta
[%]
36
32
Eta 2
14
28
Eta 1
12
24
10
20
16
12
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
4.0
0.5
1.0
1.5
2.0
v [m/s]
P1
3.5
3.0
P2
2.5
2.0
1.5
0.5
NPSH
0
0
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
1.0
96
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
685
397
171
247
321
103
80
160
8 x M16
80
160
8 x 18
90.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
750
557
408
81
1.5
782
97
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
813
373
128
330
280
530
80
18
Electrical data
Voltage
[V]
Pump type
SLV.65.80.30.2.60G
SLV.65.80.30.2.61F
SLV.65.80.30.2.61G
SLV.65.80.30.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
Starting
RPM
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
3.8
3.0
3510
DOL
6.0
0.87
0.00670
35
3.8
3.0
3510
SD
10.4
0.87
0.00670
35
3.8
3.8
3.0
3.0
2
2
3510
3510
SD
DOL
6.0
10.4
0.87
0.87
0.00670
0.00670
35
35
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
97
10
Performance curves Technical data
H
[m]
SLV.65.80.40.2.6
28
60 Hz
ISO 9906 Annex A
QH
24
Eta
[%]
35
Eta 2
20
30
Eta 1
16
25
12
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
4.5
0.5
1.0
1.5
2.0
v [m/s]
P1
4.0
3.5
P2
3.0
2.5
2.0
1.0
NPSH
0
0
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
1.5
98
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
718
455
200
276
379
106
80
160
8 x M16
80
160
8 x 18
117.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
808
616
437
81
1.5
812
94
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
846
376
128
330
280
573
80
18
Electrical data
Voltage
[V]
Pump type
SLV.65.80.40.2.60G
SLV.65.80.40.2.61F
SLV.65.80.40.2.61G
SLV.65.80.40.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
Starting
RPM
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
4.9
4.0
3530
DOL
7.7
0.88
0.01490
58
4.9
4.0
3530
SD
13.3
0.88
0.01490
58
4.9
4.9
4.0
4.0
2
2
3530
3530
SD
DOL
7.7
13.3
0.88
0.88
0.01490
0.01490
58
58
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
65
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
99
10
Performance curves Technical data
SLV.80.80
Performance curves SLV.80.80.11
H
[m]
9
SLV.80.80.11.4.6
60 Hz
ISO 9906 Annex A
QH
Eta
[%]
40
35
Eta 2
30
Eta 1
25
20
15
10
10
0.0
0.5
20
10
30
12
40
14
16Q [l/s]
50
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0 v [m/s]
DN 100
0.0
P
[kW]
2.0
0.5
1.0
1.5
2.0 v [m/s]
1.6
P1
1.2
P2
0.8
0.4
NPSH
[m]
4
2
0.0
0
0
100
4
10
6
20
8
30
10
12
40
14
16Q [l/s]
50
Q [m/h]
NPSH
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
409
171
241
339
109
80
160
8 x M16
80
160
8 x 18
93.20
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
762
569
402
81
1.5
802
91
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
839
379
128
330
280
527
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.11.4.60G 3 x 380-480 V Y
SLV.80.80.11.4.61G 3 x 380-480 V D
3 x 220-277 V D /
SLV.80.80.11.4.61F
380-480 V Y
SLV.80.80.11.4.60F 3 x 220-277 V D
1.5
1.5
1.1
1.1
4
4
1750
1750
motor [%]
IN
Istart
[A]
[A]
1/2
DOL
SD
2.7
2.7
19.0
19.0
65
65
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
0.01400
0.01400
22
22
1.5
1.1
1750
SD
4.6
0.01400
22
1.5
1.1
1750
DOL
4.6
0.01400
22
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
101
10
Performance curves Technical data
H
[m]
9
SLV.80.80.13.4.6
QH
60 Hz
ISO 9906 Annex A
Eta 2
Eta
[%]
40
35
30
Eta 1
25
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
Q [l/s]
60 Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
v [m/s]
DN 100
0.5
1.0
1.5
2.0
v [m/s]
1.6
P1
1.2
P2
0.8
0.4
0.0
102
NPSH
4
10
6
20
8
30
NPSH
[m]
4
10
12
40
14
50
16
Q [l/s]
60 Q [m/h]
0.0
P
[kW]
2.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
409
171
241
339
109
80
160
8 x M16
80
160
8 x 18
92.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
762
569
402
81
1.5
802
91
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
839
379
128
330
280
527
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.13.4.60G
SLV.80.80.13.4.61G
SLV.80.80.13.4.61F
SLV.80.80.13.4.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 220-277 V D
1.9
1.9
1.5
1.5
No of
poles
4
4
Starting
RPM
method
1750
1750
DOL
SD
motor [%]
Cos
IN
Istart
[A]
[A]
3.5
3.5
1/2
3/4
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
0.01550
0.01550
30
30
1.9
1.5
1750
SD
6.0
0.01550
30
1.9
1.5
1750
DOL
6.0
0.01550
30
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
103
10
Performance curves Technical data
H
[m]
11
SLV.80.80.15.4.6
60 Hz
ISO 9906 Annex A
QH
Eta
[%]
45
40
35
30
25
10
Eta 2
Eta 1
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
2.0
0.5
1.0
1.5
2.0
v [m/s]
P1
1.6
P2
1.2
NPSH
[m]
4
0.8
0.0
0
0
104
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
0.4
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
409
171
241
339
109
80
160
8 x M16
80
160
8 x 18
92.8
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
762
569
402
81
1.5
802
91
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
839
379
128
330
280
527
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.15.4.60G
SLV.80.80.15.4.61G
SLV.80.80.15.4.61F
SLV.80.80.15.4.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 220-277 V D
No of
poles
RPM
Starting
method
motor [%]
Cos
IN
Istart
[A]
[A]
3/4
1/1
1/2
3/4
1/1
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm2]
1.9
1.9
1.5
1.5
4
4
1750
1750
DOL
SD
3.5
3.5
0.77
0.77
0.01650
0.01650
30
30
1.9
1.5
1750
SD
6.0
0.77
0.01650
30
1.9
1.5
1750
DOL
6.0
0.77
0.01650
30
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
105
10
Performance curves Technical data
H
[m]
16
SLV.80.80.22.4.6
60 Hz
ISO 9906 Annex A
QH
14
Eta 2
12
Eta
[%]
50
45
Eta 1
10
40
35
30
25
20
15
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
3.0
0.5
1.0
1.5
2.0
v [m/s]
2.5
P1
2.0
P2
NPSH
[m]
4
1.5
1.0
0.0
0
0
106
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
0.5
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
409
171
241
339
109
80
160
8 x M16
80
160
8 x 18
105.1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
762
569
402
81
1.5
802
91
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
839
379
128
330
280
527
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.22.4.60G
SLV.80.80.22.4.61F
SLV.80.80.22.4.61G
SLV.80.80.22.4.60F
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
2.7
2.2
1760
DOL
4.6
0.80
0.02290
42
2.7
2.2
1760
SD
8.0
0.80
0.02290
42
2.7
2.7
2.2
2.2
4
4
1760
1760
SD
DOL
4.6
8.0
0.80
0.80
0.02290
0.02290
42
42
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
107
10
Performance curves Technical data
H
[m]
20
SLV.80.80.40.4.6
QH
60 Hz
ISO 9906 Annex A
18
16
14
Eta
[%]
50
45
Eta 2
12
40
Eta 1
10
35
30
25
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
5.0
0.5
1.0
1.5
2.0
v [m/s]
4.5
P1
4.0
P2
NPSH
[m]
6
3.5
3.0
2.5
1.5
0
0
108
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
2.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
744
456
200
276
380
109
80
160
8 x M16
80
160
8 x 18
133.50
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
809
617
437
81
1.5
840
96
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
872
374
128
330
280
574
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.40.4.60G
SLV.80.80.40.4.61F
SLV.80.80.40.4.61G
SLV.80.80.40.4.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
Starting
RPM
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
4.9
4.0
1760
DOL
8.6
0.05400
89
4.9
4.0
1760
SD
14.9
0.05400
89
4.9
4.9
4.0
4.0
4
4
1760
1760
SD
SD
8.6
14.9
0.05400
0.05400
89
89
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
109
10
Performance curves Technical data
H
[m]
20
SLV.80.80.40.2.6
QH
60 Hz
ISO 9906 Annex A
18
Eta
[%]
28
16
14
Eta 2
12
24
Eta 1
10
20
16
12
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
5.0
0.5
1.0
1.5
2.0
v [m/s]
P1
4.5
4.0
P2
NPSH
[m]
8
3.5
3.0
2.5
2.0
0
0
110
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
NPSH
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
748
460
200
267
393
104
80
160
8 x M16
80
160
8 x 18
133.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
813
620
428
81
1.5
839
96
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
876
379
128
330
280
578
80
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SLV.80.80.40.2.61G 3 x 380-480 V D
SLV.80.80.40.2.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.80.80.40.2.60G
4.9
4.0
3530
DOL
7.7
0.01490
58
SLV.80.80.40.2.61F
4.9
4.0
3530
SD
13.3
0.01490
58
4.9
4.9
4.0
4.0
2
2
3530
SD
DOL
7.7
13.3
0.01490
0.01490
58
58
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
111
10
Performance curves Technical data
H
[m]
SLV.80.80.60.2.6
28
60 Hz
ISO 9906 Annex A
QH
24
Eta
[%]
35
Eta 2
20
30
Eta 1
16
25
12
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
7.0
0.5
1.0
1.5
2.0
v [m/s]
P1
6.5
6.0
P2
5.5
5.0
4.5
3.5
NPSH
0
0
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
4.0
112
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
751
456
200
276
380
104
80
160
8 x M16
80
160
8 x 18
138.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
809
617
437
81
1.5
847
96
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
879
374
128
330
280
574
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.60.2.60G
SLV.80.80.60.2.61F
SLV.80.80.60.2.61G
SLV.80.80.60.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
RPM
Starting
method
motor [%]
Cos
IN
Istart
[A]
[A]
1/2
3/4
1/1
3/4
1/1
0.8
0.8
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
8.9
7.5
3520
DOL
13.9
107
0.88
0.01900
77
8.9
7.5
3520
SD
23.5
0.88
0.01900
77
8.9
8.9
7.5
7.5
2
2
3520
3520
SD
DOL
13.9
23.5
0.88
0.88
0.01900
0.01900
77
77
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
113
10
Performance curves Technical data
H
[m]
36
SLV.80.80.75.2.6
60 Hz
ISO 9906 Annex A
QH
32
28
Eta 2
24
20
Eta
[%]
40
35
30
Eta 1
16
25
12
20
15
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
9
0.5
1.0
1.5
2.0
v [m/s]
P1
P2
NPSH
[m]
6
6
5
4
0
0
114
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
751
456
200
276
380
104
80
160
8 x M16
80
160
8 x 18
139.1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
809
617
437
81
1.5
847
96
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
879
374
128
330
280
574
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.75.2.60G
SLV.80.80.75.2.61F
SLV.80.80.75.2.61G
SLV.80.80.75.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
No of
poles
RPM
Starting
method
motor [%]
Cos
IN
Istart
[A]
[A]
1/2
3/4
1/1
3/4
1/1
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
8.9
7.5
3520
DOL
13.9
107
0.8
0.8
0.88
0.02200
77
8.9
7.5
3520
SD
13.9
107
0.8
0.8
0.88
0.02200
77
8.9
8.9
7.5
7.5
2
2
3520
3520
SD
SD
13.9
13.9
107
107
0.8
0.8
0.8
0.8
0.88
0.88
0.02200
0.02200
77
77
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
115
10
Performance curves Technical data
H
[m]
40
SLV.80.80.92.2.6
60 Hz
ISO 9906 Annex A
QH
36
32
Eta 2
28
32
Eta 1
24
Eta
[%]
36
28
20
24
16
20
12
16
12
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
11
0.5
1.0
1.5
2.0
v [m/s]
P1
10
9
P2
NPSH
[m]
6
8
7
5
0
0
116
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
782
489
217
293
413
123
80
160
8 x M16
80
160
8 x 18
181.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
842
650
454
81
1.5
858
77
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
910
393
128
330
280
607
80
18
Electrical data
Voltage
[V]
Pump type
SLV.80.80.92.2.60G
SLV.80.80.92.2.61F
SLV.80.80.92.2.61G
SLV.80.80.92.2.60F
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
3 x 380-480 V D
3 x 220-277 V D
12.7
11.0
No of
poles
RPM
3550
Starting
method
DOL
motor [%]
Cos
IN
Istart
[A]
[A]
3/4
1/1
19.4
0.89
1/2
3/4
1/1
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm2]
0.05100
86
12.7
11.0
3550
SD
33.6
0.89
0.05100
86
12.7
12.7
11.0
11.0
2
2
3550
3550
SD
DOL
19.4
33.6
0.89
0.89
0.05100
0.05100
86
86
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
117
10
Performance curves Technical data
H
[m]
45
SLV.80.80.110.2.6
60 Hz
ISO 9906 Annex A
QH
40
35
Eta 2
Eta 1
30
Eta
[%]
35
30
25
25
20
20
15
15
10
10
10
0.0
0.5
6
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 80
1.0
1.5
2.0
2.5
3.0
3.5
v [m/s]
DN 100
0.0
P
[kW]
13
0.5
1.0
1.5
2.0
v [m/s]
12
P1
P2
10
9
NPSH
0
0
118
NPSH
[m]
6
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
11
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
782
489
217
293
413
123
80
160
8 x M16
80
160
8 x 18
181.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
220
95
160
842
650
454
81
1.5
858
77
13
171
345
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
910
393
128
330
280
607
80
18
Electrical data
Starting
P1
P2 No of
RPM
method
[kW] [kW] poles
Voltage
[V]
Pump type
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SLV.80.80.110.2.61G 3 x 380-480 V D
SLV.80.80.110.2.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.80.80.110.2.60G
12.7
11.0
3550
DOL
19.4
0.89
0.05300
86
SLV.80.80.110.2.61F
12.7
11.0
3550
SD
33.6
0.89
0.05300
86
12.7
12.7
11.0
11.0
2
2
3550
3550
SD
DOL
19.4
33.6
0.89
0.89
0.05300
0.05300
86
86
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
119
10
Performance curves Technical data
SLV.80.100
Performance curves SLV.80.100.11
H
[m]
8
SLV.80.100.11.4.6
60 Hz
ISO 9906 Annex A
QH
Eta 2
Eta
[%]
35
30
Eta 1
25
20
15
10
4
10
20
10
30
12
40
14
16
50
Q [l/s]
60 Q [m/h]
DN 100
0.0
0.5
1.0
1.5
2.0
v [m/s]
DN 150
0.0
P
[kW]
0.2
0.4
0.6
0.8
v [m/s]
1.6
P1
1.2
P2
0.8
0.4
NPSH
[m]
4
2
0.0
0
0
120
4
10
6
20
8
30
10
12
40
14
50
16
Q [l/s]
60 Q [m/h]
NPSH
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
407
171
241
336.5
109
80
160
8 x M16
100
180
8 x 18
94.2
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
850
624
458
110
2.0
842
131
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
839
354
128
330
280
548.7
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
SLV.80.100.11.4.61G 3 x 380-480 V Y
SLV.80.100.11.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.80.100.11.4.60G
1.5
1.1
1750
DOL
2.7 19.0
65
22
SLV.80.100.11.4.61F
1.5
1.1
1750
SD
4.6 32.9
65
22
1.5
1.5
1.1
1.1
4
4
1750
1750
SD
DOL
2.7 19.0
4.6 32.9
65
65
22
22
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
121
10
Performance curves Technical data
H
[m]
9
SLV.80.100.13.4.6
60 Hz
ISO 9906 Annex A
QH
8
7
Eta 2
Eta
[%]
40
35
30
Eta 1
25
20
15
10
4
10
20
10
30
12
40
14
16
50
18
60
Q [l/s]
Q [m/h]
DN 100
0.0
0.5
1.0
1.5
2.0
v [m/s]
DN 150
0.0
P
[kW]
2.0
0.2
0.4
0.6
0.8
1.0
1.6
v [m/s]
P1
1.2
P2
0.8
0.0
0
0
122
NPSH
4
10
6
20
8
30
10
12
40
14
50
16
60
18
Q [l/s]
Q [m/h]
0.4
NPSH
[m]
4
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
407
171
241
336.5
109
80
160
8 x M16
100
180
8 x 18
93.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
850
624
458
110
842
131
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
369
130
335
300
591
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
SLV.80.100.13.4.61G 3 x 380-480 V Y
SLV.80.100.13.4.60F 3 x 220-277 V D
No of
poles
Starting
method
RPM
motor [%]
Cos
IN
Istart
[A]
[A]
3/4
1/1
SLV.80.100.13.4.60G
1.9
1.5
1750
DOL
3.5
SLV.80.100.13.4.61F
1.9
1.5
1750
SD
1.9
1.9
1.5
1.5
4
4
1750
1750
SD
DOL
3.5
6
1/2
3/4
1/1
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
0.77
0.01550
0.77
0.01550
30
0.77
0.77
0.01550
0.01550
30
30
44
30
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
123
10
Performance curves Technical data
H
[m]
10
SLV.80.100.15.4.6
60 Hz
ISO 9906 Annex A
QH
9
8
Eta 2
Eta
[%]
45
40
35
30
Eta 1
25
20
15
10
4
10
20
30
10 12 14 16 18 20
40
50
60
Q [l/s]
70
Q [m/h]
2.5
v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
DN 150
0.0
P
[kW]
2.0
0.2
0.4
0.6
0.8
1.0
v [m/s]
P1
1.6
P2
1.2
NPSH
[m]
4
0.8
0.0
0
0
124
NPSH
4
10
6
20
8
30
10 12 14 16 18 20
40
50
60
70
Q [l/s]
Q [m/h]
0.4
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
407
171
241
336.5
109
80
160
8 x M16
100
180
8 x 18
93.8
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
850
624
458
110
842
131
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
369
130
335
300
591
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
SLV.80.100.15.4.61G 3 x 380-480 V Y
SLV.80.100.15.4.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
motor [%]
Cos
IN
Istart
[A]
[A]
3/4
1/1
SLV.80.100.15.4.60G
1.9
1.5
1750
DOL
3.5
SLV.80.100.15.4.61F
1.9
1.5
1750
SD
1.9
1.9
1.5
1.5
4
4
1750
1750
SD
DOL
3.5
6
1/2
3/4
1/1
1/2
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
0.77
0.01650
30
0.77
0.01650
30
0.77
0.77
0.01650
0.01650
30
30
44
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
125
10
Performance curves Technical data
H
[m]
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SLV.80.100.22.4.6
60 Hz
ISO 9906 Annex A
QH
Eta 2
Eta 1
0
0
10
8 10 12 14 16 18 20 22 24 Q [l/s]
20
30
40
50
60
70
80
Eta
[%]
50
45
40
35
30
25
20
15
10
5
0
Q [m/h]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0 v [m/s]
DN 150
0.0
P
[kW]
3.0
0.2
0.4
0.6
0.8
1.0
1.2
2.5
v [m/s]
P1
2.0
P2
1.5
1.0
0
0
126
NPSH
2
10
6
20
8 10 12 14 16 18 20 22 24 Q [l/s]
30
40
50
60
70
80
Q [m/h]
0.5
0.0
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
711
407
171
241
336.5
109
80
160
8 x M16
100
180
8 x 18
106
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
850
624
458
110
842
131
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
812
369
130
335
300
591
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SLV.80.100.22.4.60G
3 x 380-480 V Y
3 x 220-277 V D /
SLV.80.100.22.4.61F
380-480 V Y
SLV.80.100.22.4.61G 3 x 380-480 V Y
SLV.80.100.22.4.60F 3 x 220-277 V D
Cos
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm 2]
Istart
[A]
[A]
4.6
0.02290
SD
0.02290
42
SD
DOL
4.6
8
0.02290
0.02290
42
42
RPM
2.2
1760
DOL
2.7
2.2
1760
2.7
2.7
2.2
2.2
4
4
1760
1760
2.7
motor [%]
IN
Starting
method
No of
poles
1/2
3/4
1/1
1/2
3/4
1/1
42
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
127
10
Performance curves Technical data
H
[m]
18
SLV.80.100.40.4.6
60 Hz
ISO 9906 Annex A
QH
16
14
Eta
[%]
45
12
40
10
35
30
25
Eta 2
20
Eta 1
15
10
12
20
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
5.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
4.5
v [m/s]
P1
4.0
P2
3.5
NPSH
[m]
4
3.0
2.5
1.5
0
0
128
NPSH
8
20
12
40
16
60
20
24
80
28
32 Q [l/s]36
100
Q [m/h]
2.0
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
744
466
200
286
380
109
80
160
8 x M16
100
180
8 x 18
134.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
909
683
503
110
876
131
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
878
395
130
355
300
647
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SLV.80.100.40.4.60G 3 x 380-480 V D
3 x 220-277 V D /
SLV.80.100.40.4.61F
380-480 V Y
SLV.80.100.40.4.61G 3 x 380-480 V D
SLV.80.100.40.4.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
4.9
4.0
1760
DOL
8.6
0.05400
89
4.9
4.0
1760
SD
14.9
0.05400
89
4.9
4.9
4.0
4.0
4
4
1760
1760
SD
DOL
8.6
14.9
0.05400
0.05400
89
89
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
129
10
Performance curves Technical data
H
[m]
18
SLV.80.100.40.2.6
QH
60 Hz
ISO 9906 Annex A
16
Eta
[%]
28
14
12
24
Eta 2
10
20
Eta 1
16
12
4
10
20
30
10 12 14 16 18 20 22 Q [l/s]
40
50
60
70
80Q [m/h]
2.5
v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
DN 150
0.0
P
[kW]
5.0
0.2
0.4
0.6
0.8
1.0
1.2
v [m/s]
P1
4.5
4.0
P2
3.5
3.0
2.5
1.5
NPSH
0
0
4
10
6
20
8
30
10 12 14 16 18 20 22 Q [l/s]
40
50
60
70
80Q [m/h]
2.0
130
NPSH
[m]
8
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
748
458
200
267
391
104
80
160
8 x M16
100
180
8 x 18
134.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
901
675
484
110
857
136
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
876
354
128
330
280
600
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SLV.80.100.40.2.60G
3 x 380-480 V D
3 x 220-277 V D /
SLV.80.100.40.2.61F
380-480 V Y
SLV.80.100.40.2.61G 3 x 380-480 V D
SLV.80.100.40.2.60F 3 x 220-277 V D
4.9
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm 2]
4.0
3530
DOL
7.7
0.01490
58
4.9
4.0
3530
SD
13.3
0.01490
58
4.9
4.9
4.0
4.0
2
2
3530
3530
SD
DOL
0.01490
0.01490
58
58
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
131
10
Performance curves Technical data
H
[m]
20
SLV.80.100.60.2.6
60 Hz
ISO 9906 Annex A
QH
18
14
Eta 2
Eta
[%]
28
12
Eta 1
24
16
10
20
16
12
20
12
16
40
20
60
24
80
28 Q [l/s]
Q [m/h]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5 v [m/s]
DN 150
0.2
0.4
0.6
0.8
1.0
1.2
1.4
P1
NPSH
[m]
16
12
P2
2
1
NPSH
0
0
132
v [m/s]
8
20
12
40
16
60
20
24
80
28 Q [l/s]
Q [m/h]
0.0
P
[kW]
7
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
751
466
200
286
380
104
80
160
8 x M16
100
180
8 x 18
139.5
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
909
683
53
110
883
136
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
879
353
128
330
280
598
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SLV.80.100.60.2.60G 3 x 380-480 V D
3 x 220-277 V D /
SLV.80.100.60.2.61F
380-480 V Y
SLV.80.100.60.2.61G 3 x 380-480 V D
SLV.80.100.60.2.60F 3 x 220-277 V D
motor [%]
Cos
IN
Istart
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
8.9
7.5
3520
DOL
13.9
107
0.8
0.8
0.01900
77
8.9
7.5
3520
SD
23.5
196
0.8
0.8
0.01900
77
8.9
8.9
7.5
7.5
2
2
3520
3520
SD
DOL
13.9
23.5
107
196
0.8
0.8
0.8
0.8
0.01900
0.01900
77
77
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
133
10
Performance curves Technical data
H
[m]
SLV.80.100.75.2.6
60 Hz
ISO 9906 Annex A
28
QH
24
Eta 2
Eta 1
20
Eta
[%]
30
25
16
20
12
15
10
8
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
9
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
P1
8
6
NPSH
[m]
16
12
P2
NPSH
0
0
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
134
v [m/s]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
782
499
217
303
413
104
80
160
8 x M16
100
180
8 x 18
139.7
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
942
716
520
110
899
136
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
879
353
128
330
280
598
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
SLV.80.100.75.2.60G 3 x 380-480 V D
3 x 220-277 V D /
SLV.80.100.75.2.61F
380-480 V Y
SLV.80.100.75.2.61G 3 x 380-480 V D
SLV.80.100.75.2.60F 3 x 220-277 V D
8.9
7.5
No of
poles
RPM
3520
Starting
method
DOL
motor [%]
Cos
IN
Istart
[A]
[A]
1/2
3/4
1/1
13.9
107
0.8
0.8
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm 2]
0.02200
77
8.9
7.5
3520
SD
23.5
196
0.8
0.8
0.02200
77
8.9
8.9
7.5
7.5
2
2
3520
3520
SD
DOL
13.9
23.5
107
196
0.8
0.8
0.8
0.8
0.02200
0.02200
77
77
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
135
10
Performance curves Technical data
H
[m]
36
SLV.80.100.92.2.6
60 Hz
ISO 9906 Annex A
QH
32
28
Eta 2
24
Eta
[%]
35
30
Eta 1
20
25
16
20
12
15
10
8
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
11
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
v [m/s]
P1
10
9
P2
NPSH
[m]
12
8
7
6
0
0
136
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
NPSH
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
782
499
217
303
413
123
80
160
8 x M16
100
180
8 x 18
182.1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
942
716
520
110
899
117
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
910
368
128
330
280
641
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2
[kW] [kW]
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SLV.80.100.92.2.61G 3 x 380-480 V D
SLV.80.100.92.2.60F 3 x 220-277 V D
No of
poles
RPM
Starting
method
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.80.100.92.2.60G
12.7
11.0
3550
DOL
19.4
0.05100
86
SLV.80.100.92.2.61F
12.7
11.0
3550
SD
33.6
0.05100
86
12.7
12.7
11.0
11.0
2
2
3550
3550
SD
DOL
19.4
33.6
0.05100
0.05100
86
86
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
137
10
Performance curves Technical data
H
[m]
40
SLV.80.100.110.2.6
60 Hz
ISO 9906 Annex A
QH
32
Eta
[%]
40
28
35
24
30
36
20
25
Eta 2
16
Eta 1
20
12
15
10
8
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
12
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
v [m/s]
P1
11
P2
10
NPSH
[m]
12
9
8
7
0
0
138
NPSH
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
782
499
217
303
413
123
80
160
8 x M16
100
180
8 x 18
182.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
942
716
520
110
899
117
220
413
80
4 x M16
V1
V2
V3
V4
V5
V6
V7
910
368
128
330
280
641
100
18
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SLV.80.100.110.2.60G 3 x 380-480 V D
3 x 220-277 V D /
SLV.80.100.110.2.61F
380-480 V Y
SLV.80.100.110.2.61G 3 x 380-480 V D
SLV.80.100.110.2.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
12.7
11.0
3550
DOL
19.4
0.05300
86
12.7
11.0
3550
SD
33.6
0.05300
86
12.7
12.7
11.0
11.0
2
2
3550
3550
SD
DOL
19.4
33.6
0.05300
0.05300
86
86
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
80
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
139
10
Performance curves Technical data
SLV.100.100
Performance curves SLV.100.100.30
H
[m]
11
SLV.100.100.30.4.6
60 Hz
ISO 9906 Annex A
QH
10
9
7
Eta
[%]
28
24
20
16
12
Eta 2
Eta 1
20
12
16
40
20
60
24
28 Q [l/s]
80
Q [m/h]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5 v [m/s]
DN 150
0.0
P
[kW]
5
0.2
0.4
0.6
0.8
1.0
1.2
1.4
v [m/s]
P1
NPSH
[m]
4
P2
0
0
140
NPSH
8
20
12
40
16
60
20
24
80
28 Q [l/s]
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
737
457
200
277
380
134
100
180
8 x M16
100
180
8 x 18
125.4
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
270
900
674
494
110
844
106
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
867
411
130
355
300
599
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3 x 380-480 V Y
3 x 220-277 V D /
380-480 V Y
SLV.100.100.30.4.61G 3 x 380-480 V D
SLV.100.100.30.4.60F 3 x 380-480 V Y
IN
Istart
[A]
[A]
6.3
motor [%]
1/2
3/4
1/1
Cos
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.100.100.30.4.60G
3.7
3.0
1750
DOL
0.04690
60
SLV.100.100.30.4.61F
3.7
3.0
1750
SD
0.04690
60
3.7
3.7
3.0
3.0
4
4
1750
1750
SD
DOL
0.04690
0.04690
60
60
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
141
10
Performance curves Technical data
H
[m]
16
SLV.100.100.40.4.6
60 Hz
ISO 9906 Annex A
QH
14
Eta
[%]
40
Eta 2
12
35
Eta 1
10
30
25
20
15
10
12
20
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
5
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
v [m/s]
P1
P2
NPSH
[m]
4
0
0
142
NPSH
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
759
457
200
277
380
134
100
180
8 x M16
100
180
8 x 18
128.7
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
900
674
494
110
866
106
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
889
411
130
355
300
599
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SLV.100.100.40.4.60G
3 x 380-480 V D
3 x 220-277 V D /
SLV.100.100.40.4.61F
380-480 V Y
SLV.100.100.40.4.61G 3 x 380-480 V D
SLV.100.100.40.4.60F 3 x 220-277 V D
4.9
4.0
1760
DOL
motor [%]
Cos
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
[kgm 2]
IN
Istart
[A]
[A]
8.6
0.05500
89
1/2
3/4
1/1
1/2
3/4
1/1
4.9
4.0
1760
SD
0.05500
89
4.9
4.9
4.0
4.0
4
4
1760
1760
SD
DOL
0.05500
0.05500
89
89
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
143
10
Performance curves Technical data
H
[m]
20
SLV.100.100.55.4.6
60 Hz
ISO 9906 Annex A
QH
16
Eta
[%]
50
14
45
12
40
18
10
Eta 2
Eta 1
35
30
25
20
15
10
8
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
7
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
v [m/s]
P1
P2
5
4
3
4
NPSH
0
0
144
8
20
12
40
2
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
2
1
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
766
457
200
277
380
134
100
180
8 x M16
100
180
8 x 18
135.1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
900
674
494
110
873
106
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
896
411
130
355
300
599
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
SLV.100.100.55.4.60G
6.4
5.5
1760
DOL
SLV.100.100.55.4.61F
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SLV.100.100.55.4.61G 3 x 380-480 V D
SLV.100.100.55.4.60F 3 x 220-277 V D
6.4
5.5
1760
SD
6.4
6.4
5.5
5.5
4
4
1760
1760
SD
DOL
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
1/1
Cos
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
0.06656
98
0.06656
98
0.06656
0.06656
98
98
18
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
145
10
Performance curves Technical data
H
[m]
22
SLV.100.100.75.4.6
QH
60 Hz
ISO 9906 Annex A
20
18
16
Eta 2
14
Eta 1
Eta
[%]
50
45
40
12
35
10
30
25
20
15
10
8
20
12
16
40
20
60
24
80
28
32Q [l/s]
100
Q [m/h]
3.5
4.0 v [m/s]
DN 100
0.0
0.5
1.0
1.5
2.0
2.5
3.0
DN 150
0.0
P
[kW]
9
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
v [m/s]
P1
P2
7
6
5
0
0
146
NPSH
8
20
12
40
16
60
20
24
80
28
32Q [l/s]
100
Q [m/h]
4
3
NPSH
[m]
6
10
DN1
Dc1
D1 D1n
DN2
Dc2
D2 D2n
Weight [kg]
842
490
217
294
413
145
100
180
8 x M16
100
180
8 x 18
177.6
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12a
Z14
Z15
Z16
ZDN1
ZM
260
110
220
933
707
551
110
938
95
220
413
100
4 x M16
V1
V2
V3
V4
V5
V6
V7
972
422
130
355
300
632
100
19
Electrical data
Voltage
[V]
Pump type
P1
P2 No of
Starting
RPM
[kW] [kW] poles
method
3 x 380-480 V D
3 x 220-277 V D /
380-480 V Y
SLV.100.100.75.4.61G 3 x 380-480 V D
SLV.100.100.75.4.60F 3 x 220-277 V D
IN
Istart
[A]
[A]
motor [%]
1/2
3/4
Cos
1/1
1/2
3/4
1/1
Moment
Breakdown
of
torque
inertia
Mmax [Nm]
2
[kgm ]
SLV.100.100.75.4.60G
8.6
7.5
1760
DOL
13.6
0.08100
135
SLV.100.100.75.4.61F
8.6
7.5
1760
SD
23.6
0.08100
135
8.6
8.6
7.5
7.5
4
4
1760
1760
SD
DOL
13.6
23.6
0.08100
0.08100
135
135
Pump data
Impeller type
SuperVortex
Max.
Pump housing
solids size
pressure
[mm]
PN
100
10
Max. number of
starts per hour
Max. installation
depth
Enclosure
class
[m]
20
20
pH
[C]
IP68
40
4-14
147
11
Accessories
11. Accessories
DN 150 / DN 100
DN 80 / 3"
96825161
96887674
96102253
96102378
96102439
96102254
96943236
96102313
96102255
96102314
96102256
96102379
96102380
DN 80 / DN 65 / R 2 1/2"
DN 80 / DN 80 / R 3
96102440
DN 80/DN 100/R 4
DN 150 / DN 100 / R 4,
Galvanised steel
DN 150/DN 150/R 6,
Galvanised steel
DN 100 / DN 100 / R 4
96102241
96825142
DN 100 / DN 80 / 3"
DN 100 / DN 80 / R 3
96825119
DN 80 / DN 100 / 4"
DN 65 / DN 80 / R 3
SLV.100.100
SLV.80.80
DN 80 / DN 80 / 3"
DN 65 / DN 65 / R 2 1/2
SLV.80.100
SLV.65.80
96090995
DN 100 / 4"
96090994
96102240
DN 80 / DN 65 / 2 1/2"
148
SLV.65.65
DN 65 / DN 80 / 3"
96102238
DN 150 / 6"
96090993
Product
number
96090992
DN 150
DN 65 / DN 65 / 2 1/2"
DN 100 / DN 80
DN 100
DN 65 / 2"
Intermediate guide rail
holders in stainless steel
(EN 1.4308/AISI 304
DN 80
DN 80 / DN 65
SL1.100.150
DN 65
SL1.100.100
Complete auto-coupling
system, including guide shoe,
base plate and upper guide
rail holder. Cast iron,
epoxy-coated. With bolts, nuts
and gaskets.
Note: If your guide rails
exceeds 4 meter, please
consider the use of
intermediate guide rail
holders to support your
system.
SL1.80.100
Dimensions
SL1.80.80
Description
SL1.50.80
Picture
SL1.50.65
Installation systems
96102381
96943237
96102382
96102383
96102384
96102385
11
SL1.100.150
SLV.65.65
SLV.65.80
SLV.80.80
SLV.100.100
Product
number
96735550
96735553
96735554
96735556
96735557
96735559
96735564
96735566
96735567
96735569
Accessories
SL1.100.100
800
SL1.80.100
800
SL1.80.80
Max. load
[kg]
SL1.50.80
Description
Picture
SL1.50.65
Other accessories
149
11
CU 361 control panel
1
2
3
4
5
6
7
8
Dedicated Controls
9
10
11
12
13
GrA6270
Pos. Description
150
1
2
3
4
5
6
7
8
9
10
11
12
13
Display
Arrow to the right
Help
Up
Down
Plus
Minus
Esc
Home
OK (accept)
Indicator ligth, operation (green)
Indicator light, fault (red)
Contrast
Accessories
Level controllers
11
Accessories
Menu Alarm
Menu Status
Description
Graphical illustration of system (upper display half).
Clear text parameters.
Indication of alarms that occur during operation
(top and middle of display).
Reading of performance of system and individual
pumps (lower display half).
Button
for further information.
Active buttons are illuminated.
Menu Operation
Description
Current alarm and alarm log with detailed
information:
What the cause of the fault is.
Where the fault occurred: System, Pump no. 1
When the fault occurred (time and date).
When the fault disappeared (time and date).
Alarm snapshot reading of system and pump
parameters at the time of alarm
Alarm log with up to 24 historical warnings and
alarms.
Button
for further information.
Active buttons are illuminated.
Menu Settings
Description
Setting of basic parameters, for instance start/stop
levels,
Setting of auto/on/off of system or individual pumps.
Resetting of alarm relays.
Button
for further information
Active buttons are illuminated.
Description
Various settings:
Setting of analogue/digital inputs and outputs
Setting of application optimised functions such as
energy optimisation, foam drainage and advanced
alternation
Display language
Communication settings
Ethernet, etc.
Button
for further information.
Active buttons are illuminated.
151
11
LC and LCD
The Grundfos LC and LCD ranges of level controllers
comprise three series with a total of six variants:
LC and LCD 107 level controllers operated by air
bells
LC and LCD 108 level controllers operated by float
switches
LC and LCD 110 level controllers operated by
electrodes.
All controllers are ideally suited for applications
requiring up to 11 kW motors for direct-on-line starting.
The LC and LCD can also be supplied with an
integrated star-delta starter for applications requiring
larger motors up to and including 30 kW.
152
LCD 110
Accessories
DC
LC
LCD
Accessories
Name
11
Application
One pump
Two pumps
Mixer
Battery back-up
Float switch
Level sensor
Electrodes
Air bell
Pressure sensor
Ultrasonic sensor
Starting method
Direct-on-line starting (DOL)
Star-delta starting
Soft starter
Basic functions
Start and stop of pump(s)
Pump alternation
High-level alarm
Pump statistics
Test run/anti-seizing
1)
1)
Advanced functions
Communication
SMS messaging
2)
2)
User interface
1)
2)
Level indication
Graphical display
PC Tool WW Controls
153
12
Further product documentation
Catalogue
This section is based on fields of application and pump types,
and contains
technical data
curves (QH, Eta, P1, P2, etc) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
product photos
dimensional drawings
wiring diagrams
quotation texts, etc.
Literature
In this section you can access all the latest documents of a given
pump, such as
data booklets
installation and operating instructions
service documentation, such as Service kit catalogue and
Service kit instructions
quick guides
product brochures.
Service
This section contains an easy-to-use interactive service
catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, this section contains service videos showing you
how to replace service parts.
154
Sizing
12
1
Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare
Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.
CAD drawings
In this section it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
.dxf, wireframe drawings
.dwg, wireframe drawings.
3-dimensional drawings:
.dwg, wireframe drawings (without surfaces)
.stp, solid drawings (with surfaces)
.eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 185,000 Grundfos products
in more than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.
Fig. 34 WinCAPS CD-ROM
155
97656960
1211
GB
ECM: 1085390
The name Grundfos, the Grundfos logo, and the payoff BeThinkInnovate are registrated trademarks