MGE Galaxy 3000 Prospect
MGE Galaxy 3000 Prospect
MGE Galaxy 3000 Prospect
com
Galaxy 3000
10/15/20/30 kV A
Advanced Features
Parallel ready Scalable power levels Field upgradeable single to parallel module Distortion free input Network based power management Fault tolerant architecture All-in-one complete solution Compact footprint Full front access Ultra high availability topology (UHAT) Input Power Factor Correction (PFC) User friendly graphical interface Digital Power Quality Management Power surge stabilization for IT equipment startup Generator friendly technology Galaxy 3000 is available as a UL 924 system for Emergency Lighting Applications
T H E
U N I N T E R R U P T I B L E
P O W E R
P R O V I D E R
User friendly operation: With 30 years experience in the manufacture of UPS systems, MGE realizes user error accounts for a majority of UPS load drops. The Galaxy 3000s graphical user interface presents information, like operator instructions, in a clear and safe manner preventing unnecessary operator errors. Also depicted are alarm/event logs, mimic diagrams, and detailed system status information.
Galaxy 3000
Galaxy 3000 with IGBT Rectifier Traditional UPS with Input Filter UPS without Input Filter
While a UPS provides clean power on the output, the rectifier used on their input reflects disturbances back on to the utility disturbing nearby devices that share the power. Even a UPS equipped with input filters dont ensure that some distortion wont be reflected onto the utility. The above chart shows that the Galaxy 3000s IGBT rectifier is the most effective technology for reducing reflected distortion, and does not require the hidden cost and energy consumption associated with an input filter.
Output
simply by bussing the output of the modules to share the load equally. If any module goes
To Critical Load
System Maintenance Bypass
offline, the critical load is supported by the remaining modules. Should the remaining modules go offline, the critical load will automatically and seamlessly transfer to the utility via an internal module static bypass switch. Parallel intelligence resides in each module for true redundancy. MGE offers several versions of the system wrap-around bypass (SBC),
Source 1 (Main)
UPS 3
Source 1 (Main)
Integrated Parallel
including distribution and secondary UPS isolation breakers, to allow safe and hassle free operation.
Source 2 (Bypass)
UPS 1
Choice B: Galaxy 3000 Single Module in an Isolated Redundant UPS system design
Isolated Redundant
Source 1 (Main)
offers unmatched flexibility. The basic concept of this design is to always provide clean, conditioned power to the critical load, never raw utility power, regardless of UPS shutdown
UPS 2
To Critical Load
or maintenance operation. Redundancy is accomplished by installing an equally sized Single UPS modules that supplies
Source 1 (Main)
the bypass static switch and maintenance bypass of the primary module supplying the load. The illustration depicts a two module (1+1) isolated redundant system.
Communication
MGE Network Power Management Advantages Automatic shutdown/restart of an unlimited number of servers View power system status from any point on the WAN Integration with Enterprise-wide management systems Pager or E-mail notification of power events Load shedding for optimized use of backup power Environmental monitoring and management Communications cards for every application including: XML/Web, SNMP/Web, U-Talk (RS232-ASCII), RS232/RS485 (Modbus / JBUS), USB and a standard programmable dry contact card (2 input / 6 output)
Standard Features
Double Conversion On-line topology Input Power Factor Correction (IGBT rectifier) Input Distortion Management
83
28
Step Load Voltage Stabilization Intelligent Battery Management System Fault Tolerant Architecture Scalable Architecture (10 & 20 kVA models) Integrated maintenance bypass (Single Module only) Dry contact I/O card Casters with stabilizing feet Color graphic display with multilingual user interface Bottom or top entry Three communications slots
208V (220V, 480V, 600V w/aux cabinet), 3 Phase, 4 Wire + G (Parallel Module 208V only) 60 Hz, 1% (selectable to 4%), 0.1% free running 1.0% for balanced load 2.5% for 100% unbalanced load 5% for 100% step load 1% for loss or return of AC input Within 1% of nominal within 1 cycle <3% L-L and L-N for non-linear loads 120% for 1 min, 145% for 30 sec 10 x nominal current for 1 cycle 28 42 56 83 4821 7232 8895 13342 UPS: 0 to 40C (32F to 104F) Battery: 25C (77F) 20C to +45C (4F to113F) 0-95% non-condensing
W x D X H in inches ( l b s . )
23.0W X 35.5D X 48.5H (830 lbs max) 32.8W X 40.1D X 62.4H (2,565 lbs max) 18.8W X 40.1D X 62.4H (450 lbs max) 18.8W X 40.1D X 62.4H (180 lbs max) 33.0W X 35.6D X 62.4H (2,723 lbs max) 32.8W X 40.1D X 62.4H (7565 lbs max) 28.8W X 35.64D X 62.33H (300 lbs max) 18.8W X 35.64D X 62.33H (180 lbs max) ISO 9001, UL 1778, cUL, UL924, FCC Part 15, Subpart J, Class A, NEMA PE 1, NEMA 250, NFPA 70, IEC 1000 (801) level 4, OSHA
Bypass Input
(Optional)
KA2
Input Fuses
QF1
Battery System
(External Cabinet Optional)
UPS Cabinet
The Critical Power and Cooling Services Business Unit of Schneider Electric
MGE UPS SYSTEMS 1660 Scenic Avenue Costa Mesa, CA 92626 tel (800) 523-0142 (714) 557-1636 fax (714) 557-9788 American Power Conversion 132 Fairgrounds Rd. West Kingston, RI 02892 tel (401) 789-5735 ext 2128 fax (401) 788-2782
www.mgeups.com info@mgeups.com GX 3000 Revision 301 Effective: November 2007
MGE UPS SYSTEMS, Inc. All specifications subject to change without notice. The MGE UPS SYSTEMS logo is a trademark of MGE UPS SYSTEMS.
Main Input
KA1