Dehumidifier: User'S Manual
Dehumidifier: User'S Manual
Dehumidifier: User'S Manual
USERS MANUAL
CFO-12E CFO-20E
Contents
1 2 3 4 6 7 9 12 12 13 14 18
Operation Maintenance
Appendix
Operation panel Draining the water Caring for the dehumidifier Storing the dehumidifier Notation for safe operation Removing breakdowns Electric Schematic Diagram
Before using your dehumidifier, please read this users manual carefully, in order to ensure correct and safe use. After reading the manual, make sure it is stored in a safe place for future reference if necessary.
Quiet operation
When the dehumidifier operates in QUIET mode, the value of its noise is so low and makes your room quiet.
Drainage tank with a large capacity The drainage tank capacity is large to 6 liter, this will reduce the times of your discarding water.
The dehumidifier uses the no CFC refrigerant for protecting environment to reduce to pollute environment.
-1-
CFO-12E
220 230V, 50Hz
CFO-20E
20L/day 400W
The dehumidification capacity is the value obtained after the dehumidifier was continuously run in the room temperature of 30 with the relative humidity 80%. The amount of dehumidification is the amount per day(24 hours.) If specifications are changed without notice for further improvement, they are data on nameplate of the unit. The work temperature is in the range 2 to 38 . If the room temperature is beyond the range, the unit can not operate normally. working temperqture range of maximum charge dehumidifying:35 C DB/26 C WB. -2-
Cooling unit
Re-heating unit
It draws in room air, cools it with a cooling unit, and changes the humidity to drops of water. The drops of water fall into a drainage tank.
Moist air
Dried air
The dehumidified air is re-heated by a heating unit and discharged. Steps , ,and are repeated to remove humidity from the room.
Compressor
Drainage tank
After the air passes through the re-heating unit, its temperature will rise a little, so that the temperature of the room will rise appreciably. This is normal phenomenon.
-3-
Discharge port
Plastic film
Float
-5-
Operation
Operation steps:
1. Plug the power supply plug into the outlet. 2. Open the louver by hand. 3. Press the power suitch. 4. Select operation mode or let it run in the default mode. 5. Press the power switch once again to stop operation.
-6 8-
Operation
Operation panel
Indicator lamp
1.Tank full indicator lamp It will light when the drainage tank is full or positioned incorrectly. Empty the water out of the drainage tank, and make sure the tank is positioned properly. 2.Power indicator lamp It will light when the unit is plugged in. 3.mode indicator lamp lamp or When lamp or DIFY, LAUNDRY or QUIET mode. lamp is lighted, it respectively indicates that operation is in DEHUMI-
4.Humidity indicator lamp When 50% lamp, 60% lamp or 70% lamp is lighted, it respectively indicates that the current setting humidity is 50%, 60% or 70%. CON: Continuously dehumidity indicator lamp When CON lamp is lighted, it indicates that the operation is in CONTINUOUS mode. -7 6-
Operation
Switch function
5. switch Press the switch once to start operation, press it again to stop operation.
6. switch Each time the switch is pressed, the operation mode changes in the order of DEHUMIDIFY, LAUNDRY and QUIET and the corresponding mode indicator lamp will change with the operation mode. The default is DEHUMIDIFY. when the indoor temperature is above 35 , the protection device is actuated, the unit only can operate in LAUNDRY mode and pressing switch is ineffective.
7. switch Press the switch to set the humidity of the room, which can be set in order of 50%, 60% 70% and continuous, the defanlt is continuous. When the relative humidity of the room is lower than your setting humidity, the operation will stop automatically.
-8 7-
Operation
Draining the water
If the drainage tank becomes full (approx. 5.5 liters), the lamp lights to alert the user, operation stops automatically. Empty the water from the drainage tank and discard it.
Drainage steps
1. Remove the drainage tank Lightly pressing on the sides of the tank with both hands, pull it gently out.
Take hold of the handle, and then remove the tank, discard the water.
Operation
Draining the water
Continuous drainage of water
The unit has a continuous drainage port. Using a commercial hose (with an inner diameter of 15mm), the water in the drainage tank can be continuously drained out of the continuous port of the unit. When setting up the equipment for continuous drainage, always stop operation first and unplug the power supply plug.
1. Disconnect the drainage tank and open the continuous drainage port.
Use nippers or a similar tool to cut away the continuous drainage port in the side of the main unit.
Operation
Make sure at lease some place is provided around it when the unit is operating.
Note:
Please stop working and discard the water before move the dehumidifier. Tilt it within range of 30 degrees.
- 11 -
Maintenance
Caring for the dehumidifier
Clean the air filter The air filter should be cleaned approximately once two week. First, Remove the air filter, then run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is very dirty, wash it with warm water and a neutral cleaning solvent and dry it thoroughly, attach the airfilter.
2. Discard any water left in the drainage tank and wipe away any remaining drops with a cloth.
4. Store the unit Package the unit to keep it free of dust, and keep it upstanding and store it at a cool and dry place. - 12 -
Maintenance
Notation for safe operation
When use the unit, please observe the following safety precautions:
1.When the unit works in LAUNDRY mode, keep it an appropriate distance away from the clothings, and prevent the water from dropping onto it. 2.Before clean the unit or when do not use it for along period of time, unplug the power supply cord. 3.Do not wash the unit with water also put the unit close to water,explosive or flammable things. 4.Do not set the unit close to heat-generating devices or near inflammable and dangerous article. 5.Never put your fingers or objects into the intake or discharge ports. 6.Do not sit or stand on the unit. 7.Discard water that has collected in the tank timely. 8.Do not run the dehumidifier in an closed area such as inside closets, or fire can take place. 9.Do not use the unit for special purposes such as edible items, objects of art or scientific materials are stored. 10.Install drain piping in a downhill grade to make sure that condensed water can be drained continuously. 11.If the supply cord is damaged, it must be replaced by the manufacture or its service agent or a similarly qualified person in order to avoid a hazard. - 13 -
Maintenance
Removing breakdowns
If a condition listed below occurs, please check the following items to help you to save your time and cost. Condition Cause What to do
Discard the water in the drainage tank, and then reposition the tank. The protection device is actuated and the unit can not be started in case operation is under the bad environment (in that case,please do not use the dehumidifier).
- 14 -
Maintenance
Is the air filter clogged? The dehumidifying function does not work. Clean the air filter as instructed under Caring for the dehumidifier. Remove whatever is obstructing the discharge port or intake port.
No air is discharged.
Clean the air filter as instructed under Caring for the dehumidifier.
Has the unit been poorly installed so it is tilted or unsteady? Operation is noisy. Is the air filter clogged?
Use the unit in a stable, sturdy location. Prompt: Put a cushion under the unit and help to reduce operation noise. Clean the air filter as instructed under Caring for the dehumidifier.
After the above condition has occurred and corresponding step is used but the breakdown can not be removed or other breakdown occurs, please contact the authorized service centers. - 15 -
Maintenance
Removing breakdowns
The following symptoms do not indicate a breakdown Symptom
The operation noise suddenly increases during use.
Reason
The operation noise increases when the compressor is activated. Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there a device in the room such as a kerosene stove, which emits steam?
This happens if the temperature and/or humidity of the room is low. Because the temperature of the head exchanger rises abruptly, an unusual or musty odor may be produced for a moment. - 16 -
When the unit is first used, the discharged air smells musty.
Maintenance
The unit echoes. If the unit is used in a room with wood flooring or in a small room, it may echo.
When operation is started or the operation mode is changed, an unusual noise is heard in main unit. There are some stains left in the drainage tank.
This is water left from the dehumidifying test conducted at the factory, it does not indicate a problem.
The unit only can run in laundry mode and it is ineffective to press mode switch.
When the temperature of the room is above 35 the protection device is actuated , so that the unit only can run in LAUNDRY mode( the fan speed is high).
If the unit is started within 3 minutes after the unit stops, the protection device is actuated, so that the compressor is started automatically after a delay of 3 minutes; or the automatic defrosting operation is activated and the compressor stops. - 17 -
APPENDIX
Electric Schematic Diagram
- 18 -