System x3650 Type 7979 - Installation Guide
System x3650 Type 7979 - Installation Guide
System x3650 Type 7979 - Installation Guide
Type 7979
No
Installation Guide
Welcome.
Thank you for buying an IBM server. Your server is based on the X-Architecture technology, and it features superior performance, availability, and affordability. This server Installation Guide contains information for setting up and configuring your server. For detailed information about your server, view the documentation on the IBM Documentation CD. You can also find the most current information about your server at http://www.ibm.com/systems/support.
Yes
Turn off the server and install options.
Go to the Server Support flow chart on the reverse side of this page.
Install the server in the rack cabinet and cable the server and options; then, restart the server.
No
Yes
Use the IBM ServerGuide program to set up and configure hardware.
Go to the Server Support flow chart on the reverse side of this page.
No
Yes
Use ServerGuide to install the operating system?
No
Yes
Install applications, such as IBM systems management software and IBM ServeRAID programs
Server Support
Is the server working correctly?
Yes
Register the server. Go to http://www.ibm.com/support/mysupport/.
No
Check all cables for loose connections and verify that all optional devices you installed are on the ServerProven list at http://www.ibm.com/servers/eserver/ serverproven/compat/us/.
Yes
View information about IBM Support Line at http://www.ibm.com/services/sl/products/ or view support telephone numbers at http://www.ibm.com/planetwide/.
No
See the troubleshooting information that comes with the server to determine the cause of the problem and the action to take.
Yes
No Yes
Update the firmware to the latest level. You can download firmware from http://www.ibm.com/system/ support Is the problem solved?
Hardware No
Hardware or software problem?
Software
Installation Guide
Note: Before using this information and the product it supports, read the general information in Appendix B, Notices, on page 81 and the Warranty and Support Information document on the IBM System x Documentation CD.
Fourth Edition (March 2007) Copyright International Business Machines Corporation 2007. All rights reserved. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 3 4 4 6 Chapter 1. Introduction . . . . . . . The IBM System x Documentation CD . . Hardware and software requirements . Using the Documentation Browser . . Notices and statements in this document . Features and specifications . . . . . . Major components of the server . . . .
Chapter 2. Installing optional devices . . . . . Installation guidelines . . . . . . . . . . . . System reliability guidelines . . . . . . . . Working inside the server with the power on . . Handling static-sensitive devices . . . . . . Removing the cover . . . . . . . . . . . . Installing a memory module . . . . . . . . . Memory mirroring . . . . . . . . . . . . Online-spare memory . . . . . . . . . . Installing a hard disk drive . . . . . . . . . . Installing a tape drive . . . . . . . . . . . Installing an additional microprocessor . . . . . Installing an adapter . . . . . . . . . . . . Installing a Remote Supervisor Adapter II SlimLine . Replacing the ServeRAID SAS controller . . . . Completing the installation. . . . . . . . . . Installing the cover . . . . . . . . . . . Connecting the cables . . . . . . . . . . Updating the server configuration . . . . . . Chapter 3. Server controls, LEDs, Front view . . . . . . . . . Rear view . . . . . . . . . . Server power features . . . . . Turning on the server . . . . Turning off the server . . . . and . . . . . . . . . . power. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . 9 . . 9 . . 10 . . 10 . . 11 . . 11 . . 12 . . 15 . . 16 . . 18 . . 19 . . 20 . . 26 . . 29 . . 30 . . 32 . . 33 . . 33 . . 34 . . . . . . . . . . . . . . . . . . . 35 35 37 38 38 39 41 41 41 42 42 43 45
Chapter 4. Configuring the server . . . . . . . . . . . . . . . . Using the ServerGuide Setup and Installation CD . . . . . . . . . . . Using the Configuration/Setup Utility program . . . . . . . . . . . . Using the RAID configuration programs . . . . . . . . . . . . . . . Using the IBM ServeRAID Configuration Utility program . . . . . . . . Using ServeRAID Manager . . . . . . . . . . . . . . . . . . Using the baseboard management controller . . . . . . . . . . . . . Enabling and configuring SOL using the OSA SMBridge management utility program . . . . . . . . . . . . . . . . . . . . . . . . Installing the OSA SMBridge management utility program . . . . . . . Using the baseboard management controller utility programs . . . . . . Chapter 5. Solving problems Diagnostic tools overview . . POST beep codes . . . . POST error codes . . . . .
Copyright IBM Corp. 2007
. 45 . 54 . 56 . . . . 59 59 59 60
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
iii
ServerGuide problems . . . . . . . . . . . . Troubleshooting tables . . . . . . . . . . . . CD-RW/DVD drive problems . . . . . . . . . General problems . . . . . . . . . . . . . Hard disk drive problems . . . . . . . . . . Intermittent problems. . . . . . . . . . . . USB keyboard, mouse, or pointing-device problems Memory problems . . . . . . . . . . . . . Microprocessor problems . . . . . . . . . . Monitor problems . . . . . . . . . . . . . Optional-device problems . . . . . . . . . . Power problems . . . . . . . . . . . . . Serial port problems . . . . . . . . . . . . Software problems . . . . . . . . . . . . Universal Serial Bus (USB) port problems . . . . Video problems . . . . . . . . . . . . . . Light path diagnostics . . . . . . . . . . . . Diagnosing problems using light path diagnostics . Light path diagnostics LEDs . . . . . . . . . Appendix A. Getting help and technical assistance Before you call . . . . . . . . . . . . . . . Using the documentation . . . . . . . . . . . Getting help and information from the World Wide Web Software service and support . . . . . . . . . Hardware service and support . . . . . . . . . IBM Taiwan product service . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
61 62 62 63 63 64 65 66 67 68 70 70 72 73 74 74 74 75 75 79 79 79 80 80 80 80 81 81 82 83 84 85 85 86 86 86 86 86 87 87 87
Appendix B. Notices . . . . . . . . . . . . . . . Trademarks . . . . . . . . . . . . . . . . . . . Important notes . . . . . . . . . . . . . . . . . . Product recycling and disposal . . . . . . . . . . . . Battery return program . . . . . . . . . . . . . . . Electronic emission notices . . . . . . . . . . . . . Federal Communications Commission (FCC) statement . . Industry Canada Class A emission compliance statement . Avis de conformit la rglementation dIndustrie Canada . Australia and New Zealand Class A statement . . . . . United Kingdom telecommunications safety requirement . . European Union EMC Directive conformance statement . . Taiwanese Class A warning statement . . . . . . . . Chinese Class A warning statement . . . . . . . . . Japanese Voluntary Control Council for Interference (VCCI)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . statement
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
iv
Safety
Before installing this product, read the Safety Information.
Ls sikkerhedsforskrifterne, fr du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tmn tuotteen, lue turvaohjeet kohdasta Safety Information. Avant dinstaller ce produit, lisez les consignes de scurit. Vor der Installation dieses Produkts die Sicherheitshinweise lesen.
Antes de instalar este producto, lea la informacin de seguridad. Ls skerhetsinformationen innan du installerar den hr produkten.
Important: Each caution and danger statement in this document is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document. For example, if a caution statement is labeled Statement 1, translations for that caution statement are in the Safety Information document under Statement 1. Be sure to read all caution and danger statements in this document before you perform the procedures. Read any additional safety information that comes with the server or optional device before you install the device. Attention: The information in this document regarding installing and removing power supplies and connecting and disconnecting power refers to ac power supplies only. If the server contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply.
vi
Statement 1:
DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices.
To Connect: 1. Turn everything OFF. 2. First, attach all cables to devices. 3. Attach signal cables to connectors. 4. Attach power cords to outlet. 5. Turn device ON.
To Disconnect: 1. Turn everything OFF. 2. First, remove power cords from outlet. 3. Remove signal cables from connectors. 4. Remove all cables from devices.
Safety
vii
Statement 2:
CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not: v Throw or immerse into water v Heat to more than 100C (212F) v Repair or disassemble Dispose of the battery as required by local ordinances or regulations.
viii
Statement 3:
CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure.
DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following. Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite ` Laser de Classe 1 Appareil A
Safety
ix
Statement 4:
18 kg (39.7 lb)
32 kg (70.5 lb)
55 kg (121.2 lb)
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2 1
Statement 8:
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 26:
Safety
xi
xii
Chapter 1. Introduction
This Installation Guide contains instructions for setting up your IBM System x3650 Type 7979 server and basic instructions for installing some optional devices. More detailed instructions for installing optional devices are in the Users Guide on the IBM System x Documentation CD, which comes with the server. This document contains information about: v Setting up and cabling the server v Starting and configuring the server v Installing some optional devices v Solving problems Attention: The information in this document regarding installing and removing power supplies and connecting and disconnecting power refers to ac power supplies only. If the server contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply. The server has two model styles, which are based on the size and number of hard disk drive bays: v The 3.5-inch models have six 3.5-inch hot-swap hard disk drive bays. Install only 3.5-inch drives in these models. If you intend to install a tape drive, the tape drive will occupy two of the six 3.5-inch drive bays.
v The 2.5-inch models have eight 2.5-inch hot-swap hard disk drive bays and one 3.5-inch tape drive bay. Install only 2.5-inch hard disk drives and an optional 3.5-inch tape drive in these models.
Throughout this documentation, the terms 2.5-inch models and 3.5-inch models are used to distinguish between the server styles. If firmware and documentation updates are available, you can download them from the IBM Web site. The server might have features that are not described in the documentation that comes with the server, and the documentation might be updated occasionally to include information about those features, or technical updates might be available to provide additional information that is not included in the server documentation. To check for updates, complete the following steps: Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/.
Copyright IBM Corp. 2007
2. Under Product support, click System x. 3. Under Popular links, click Software and device drivers for firmware updates, or click Publications lookup for documentation updates. Note: Changes are made periodically to the IBM Web site. Procedures for locating firmware and documentation might vary slightly from what is described in this document. The server comes with an IBM ServerGuide Setup and Installation CD to help you configure the hardware, install device drivers, and install the operating system. The server comes with a limited warranty. You can obtain up-to-date information about the server and other IBM server products at http:/www.ibm.com/systems/x/. Record information about the server in the following table. You will need this information when you register the server with IBM.
Product name Machine type Model number Serial number IBM System x3650 server 7979 _____________________________________________ _____________________________________________
The model number and serial number are on the ID label on the bezel, as shown in the following illustration.
ID label
Note: This illustration shows a model with 3.5-inch serial-attached SCSI (SAS) hot-swap hard disk drives. Models with 2.5-inch SAS hot-swap hard disk drives are also available. The location of the ID label is the same on both model styles. This illustration might differ slightly from your hardware. For a list of supported optional devices for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. See the Rack Installation Instructions document for complete rack installation and removal instructions.
where e is the drive letter of the CD drive, and click OK. If you are using Red Hat Linux, insert the CD into the CD drive; then, run the following command from the /mnt/cdrom directory:
sh runlinux.sh
Select your server from the Product menu. The Available Topics list displays all the documents for your server. Some documents might be in folders. A plus sign (+) indicates each folder or document that has additional documents under it. Click the plus sign to display the additional documents. When you select a document, a description of the document appears under Topic Description. To select more than one document, press and hold the Ctrl key while you select the documents. Click View Book to view the selected document or documents in Acrobat Reader or xpdf. If you selected more than one document, all the selected documents are opened in Acrobat Reader or xpdf. To search all the documents, type a word or word string in the Search field and click Search. The documents in which the word or word string appears are listed in order of the most occurrences. Click a document to view it, and press Crtl+F to use the Acrobat search function or Alt+F to use the xpdf search function within the document. Click Help for detailed information about using the Documentation Browser.
Chapter 1. Introduction
Table 1. Features and specifications Microprocessor: v Intel Xeon FC-LGA 771 dual-core with 4 MB Level-2 cache or quad-core with 8 MB (2x4 MB) Level-2 cache v Support for up to two microprocessors v Support for Intel Extended Memory 64 Technology (EM64T) Note: v Use the Configuration/Setup Utility program to determine the type and speed of the microprocessors. v For a list of supported microprocessors, see http://www.ibm.com/servers/eserver/ serverproven/compat/us/ Memory: v Twelve DIMM connectors v Minimum: 1 GB v Maximum: 48 GB v Type: Fully buffered DIMM (FBD) PC2-5300 DIMMs only v Sizes: 512 MB, 1 GB, 2 GB, or 4 GB (when available), in pairs v Chipkill supported Drives: CD/DVD: IDE 24x CD-RW/ 8x DVD combination Expansion bays: v Hot-swap hard disk drive bays: SAS only. Number and size depend on the server model. One of the following configurations: Six 3.5-inch drive bays (optional tape drive [SATA or SCSI] requires two of these bays) Eight 2.5-inch drive bays and one tape-drive (SATA or SCSI) bay v One 5.25-inch Ultrabay Enhanced bay (CD-RW/DVD drive installed) Expansion slots: v Two PCI Express x8 slots (x4 lanes) on system board (low profile) v Support for either of the following optional riser cards: Riser card with two PCI Express x8 slots (x8 lanes) (standard) Riser card with two 133 MHz/64-bit PCI-X slots Hot-swap fans: v Standard: Five v Maximum: Ten - provide redundant cooling Hot-swap power supplies: 835 watts (100 - 240 V ac) v Minimum: One v Maximum: Two - provide redundant power ServeRAID SAS controller: v ServeRAID-8k-l SAS Controller that supports RAID levels 0, 1, 10 (standard) v Upgradeable to ServeRAID-8k SAS Controller, 256 MB with battery backup, that supports RAID levels 0, 1, 1E, 5, 6, and 10
Environment: v Air temperature: Size (2 U): Server on: 10 to 35C (50.0 to v Height: 85.4 mm (3.36 in.) 95.0F); altitude: 0 to 914.4 m v Depth: 705 mm (27.8 in.) (3000 ft). Decrease system v Width: 443.6 mm (17.5 in.) temperature by 0.75C for every v Weight: approximately 21.09 kg 1000-foot increase in altitude. (46.5 lb) to 29.03 kg (64 lb) Server off: 10 to 43C (50.0 to depending upon configuration 109.4F); maximum altitude: 2133 m (7000 ft) Integrated functions: Shipment: -40 to +60C (-40 to v Baseboard management controller 140F); maximum altitude: 2133 v Two Broadcom 10/100/1000 m (7000 ft) Ethernet controllers with Wake on LAN support and TCP/IP Offload v Humidity: Server on/off: 8% to 80% Engine (TOE) support Shipment: 5% to 100% v One RAID controller, active only when a 8k or 8k-l SAS controller Acoustical noise emissions: is installed v Declared sound power, idle: 6.8 bel v One serial port v Declared sound power, operating: v One serial-attached SCSI (SAS) 6.8 bel controller v Seven Universal Serial Bus (USB) Heat output: ports (two on front and four on rear of server, plus one internal), Approximate heat output in British v2.0 supporting v1.1 thermal units (Btu) per hour: v Two video ports (one on front and v Minimum configuration: 1230 Btu per one on rear of server) hour (360 watts) v One internal serial ATA (SATA) v Maximum configuration: 3390 Btu connector for tape per hour (835 watts) v Support for Remote Supervisor Electrical input with hot-swap ac Adapter II SlimLine power supplies: Note: In messages and v Sine-wave input (50-60 Hz) required documentation, the term service v Input voltage range automatically processor refers to the baseboard selected management controller or the v Input voltage low range: optional Remote Supervisor Adapter Minimum: 100 V ac II SlimLine. Maximum: 127 V ac v Input voltage high range: Video controller: Minimum: 200 V ac v ATI RN50 video on system board Maximum: 240 V ac v Compatible with SVGA and VGA v Input kilovolt-amperes (kVA) v 16 MB DDR video memory approximately: Minimum: 0.29 kVA Maximum: 1.00 kVA
Chapter 1. Introduction
Fans (5 or 10) Fan bracket assembly 3.5-inch hard disk drive backplane
Cover
Power-supply filler Microprocessor air baffle CD/DVD media backplane Tape drive filler Tape drive space filler Optional tape drive Operator information panel CD/DVD drive 3.5-inch filler panel 3.5-inch hard disk drive Power backplane Power supply
3.5-inch cage divider 2.5-inch hard disk drive 2.5-inch filler panel
Riser-card assembly
Full-height adapter
DIMM
System board
Chapter 1. Introduction
Installation guidelines
Before you install optional devices, read the following information: v Read the safety information that begins on page v and the guidelines in Handling static-sensitive devices on page 11. This information will help you work safely. v When you install your new server, take the opportunity to download and apply the most recent firmware updates. This step will help to ensure that any known issues are addressed and that your server is ready to function at maximum levels of performance. To download firmware updates for your server, conplete the following steps: Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. 2. 3. 4. Go to http://www.ibm.com/systems/support/. Under Product support, click System x. Under Popular links, click Software and device drivers. Click System x3650 to display the matrix of downloadable files for the server.
v v
For additional information about tools for updating, managing, and deploying firmware, see the System x and xSeries Tools Center at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp. Before you install optional hardware, make sure that the server is working correctly. Start the server, and make sure that the operating system starts, if an operating system is installed, or that a 19990305 error code is displayed, indicating that an operating system was not found but the server is otherwise working correctly. If the server is not working correctly, see Chapter 5, Solving problems, on page 59 for diagnostic information. Observe good housekeeping in the area where you are working. Place removed covers and other parts in a safe place. If you must start the server while the cover is removed, make sure that no one is near the server and that no tools or other objects have been left inside the server. Do not attempt to lift an object that you think is too heavy for you. If you have to lift a heavy object, observe the following precautions: Make sure that you can stand safely without slipping. Distribute the weight of the object equally between your feet.
Use a slow lifting force. Never move suddenly or twist when you lift a heavy object. To avoid straining the muscles in your back, lift by standing or by pushing up with your leg muscles. v Make sure that you have an adequate number of properly grounded electrical outlets for the server, monitor, and other devices. v Back up all important data before you make changes to disk drives.
Copyright IBM Corp. 2007
v Have a small flat-blade screwdriver available. v You do not have to turn off the server to install or replace hot-swap fans, redundant hot-swap ac power supplies, or hot-plug Universal Serial Bus (USB) devices. However, you must turn off the server before performing any steps that involve removing or installing adapter cables or non-hot-swap optional devices or components. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply. See the documentation that comes with each dc power supply. v Blue on a component indicates touch points, where you can grip the component to remove it from or install it in the server, open or close a latch, and so on. v Orange on a component or an orange label on or near a component indicates that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component. v When you are finished working on the server, reinstall all safety shields, guards, labels, and ground wires. v For a list of supported optional devices for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/.
10
The server supports hot-plug, hot-add, and hot-swap devices and is designed to operate safely while it is turned on and the cover is removed. Follow these guidelines when you work inside a server that is turned on: v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts before working inside the server; do not wear cuff links while you are working inside the server. v Do not allow your necktie or scarf to hang inside the server. v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist watches. v Remove items from your shirt pocket, such as pens and pencils, that could fall into the server as you lean over it. v Avoid dropping any metallic objects, such as paper clips, hairpins, and screws, into the server.
11
2. If you are planning to install or remove a microprocessor, memory module, PCI adapter, battery, or other non-hot-swap optional device, turn off the server and all attached devices and disconnect all external cables and power cords (see Turning off the server on page 39). Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Press down on the left and right side latches and pull the server out of the rack enclosure until both slide rails lock. Note: You can reach the cables on the back of the server when the server is in the locked position.
Cover-release latch
4. Lift the cover-release latch. Lift the cover off the server and set the cover aside. Attention: For proper cooling and airflow, replace the cover before you turn on the server. Operating the server for extended periods of time (more than 30 minutes) with the cover removed might damage server components.
12
Table 2. DIMM installation sequence Pair 1 2 3 4 5 6 DIMM connectors 1 and 4 7 and 10 2 and 5 8 and 11 3 and 6 9 and 12
Note: When only one pair of DIMMs is installed in the server and the BIOS code level is version 1.04 (GGE127A) or later, you can improve performance by installing the DIMMs in connectors 1 and 7 instead of 1 and 4. However, because the connectors in the pair are not on the same memory branch (see the following illustration), Chipkill memory protection is disabled.
Branch 1
Channel 2
v Each DIMM in a pair must be the same size, speed, type, and technology to ensure that the server will operate correctly. v You can configure the server to use memory mirroring. Memory mirroring stores data in two pairs of DIMMs simultaneously. If a failure occurs, the memory controller switches from the active pair to the mirroring pair. See Memory mirroring on page 15 for more information about memory mirroring and the DIMM installation sequence that is required.
13
v The server supports online-spare memory. This feature disables the failed memory from the system configuration and activates an online-spare pair of DIMMs to replace the failed active DIMM pair. See Online-spare memory on page 16 for more information about online-spare memory and the DIMM configuration that is required. v You can enable either online-spare memory or memory mirroring, but not both at the same time. Online-spare memory provides more memory capacity than mirroring; mirroring provides better memory protection but less memory capacity than online-spare memory. v When you install or remove DIMMs, the server configuration information changes. When you restart the server, the system displays a message that indicates that the memory configuration has changed.
To install a DIMM, complete the following steps: 1. Read the safety information that begins on page v and Installation guidelines on page 9. 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the cover. Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open, and close the clips gently.
14
4. 5. 6. 7.
Remove the riser-card assembly. Remove the DIMM air baffle. Open the retaining clip on each end of the DIMM connector. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the outside of the server. Then, remove the DIMM from the package. 8. Turn the DIMM so that the keys align correctly with the connector. 9. Insert the DIMM into the connector. Firmly press the DIMM straight down into the connector. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector. Note: If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it. 10. Replace the DIMM air baffle. 11. Replace the riser-card assembly. If you have other optional devices to install, do so now. Otherwise, go to Completing the installation on page 32.
Memory mirroring
You can configure the server to use memory mirroring. Memory mirroring stores data in two pairs of DIMMs simultaneously. If a failure occurs, the memory controller switches from the active pair to the mirroring pair. Memory mirroring reduces the amount of available memory. Enable memory mirroring through the Configuration/Setup Utility program. See the section about using the
Chapter 2. Installing optional devices
15
Configuration/Setup Utility program in the Users Guide on the IBM System x Documentation CD for details about enabling memory mirroring. When you use memory mirroring, you must install two pairs of DIMMs at a time. The four DIMMs in each group must be identical. See Table 3 for the DIMM connectors that are in each group.
Table 3. Memory mirroring DIMM installation sequence Group 1 2 3 DIMM connectors 1, 4, 7, and 10 2, 5, 8, and 11 3, 6, 9, and 12
Table 4. Memory mirroring DIMM functions Group 1 2 3 Active DIMMs 1, 4 2, 5 3, 6 Mirroring DIMMs 7, 10 8, 11 9, 12
Online-spare memory
The server supports online-spare memory. This feature disables the failed memory from the system configuration and activates an online-spare pair of DIMMs to replace the failed active DIMM pair. Online-spare memory reduces the amount of available memory. Before you can enable this feature, you must install up to two additional pairs of DIMMs. The online-spare DIMM pairs must be the same speed, type, and the same size as, or larger than, the largest active DIMM pairs. Enable online-spare memory through the Configuration/Setup Utility program. The BIOS code assigns the online-spare DIMM pairs according to your DIMM configuration. Online-sparing is enabled on a memory branch basis; the BIOS code does not enable online-sparing on a branch that cannot support online-sparing. See the illustration on page 13 for the memory branch structure. DIMM ranks are online-spared if the DIMMs are installed according to the rules in Table 5 on page 17 or Table 6 on page 17. Note: POST gives a warning message when online-sparing cannot be enabled on both branches. However, no warning message is given when online-sparing is enabled on one branch and disabled on the other. Online-spare configurations are supported for each branch. See Table 5 on page 17 and Table 6 on page 17 for the online-spare DIMM connector assignments. Important: Table 5 on page 17 shows the default DIMM online-spare scheme. If the BIOS code level is version 1.04 or later, you can install the DIMMs according to the scheme shown in Table 6 on page 17 instead.
16
In the configuration that you use, install the largest DIMMs first.
Table 5. Online-spare DIMM configurations, basic scheme Number of DIMMs DIMM connectors 4 6 1 and 4 (largest DIMMs) 2 and 5 1 and 4 (largest DIMMs) 2 and 5 3 and 6 1 and 4 (largest DIMMs) 2 and 5 3 and 6 7 and 10 (dual-rank DIMMs only) 10 1 and 4 (largest DIMMs) 2 and 5 3 and 6 7 and 10 8 and 11 12 1 and 4 (largest DIMMs) 2 and 5 3 and 6 7 and 10 8 and 11 9 and 12 Table 6. Online-spare DIMM configurations, alternative scheme (requires BIOS code version 1.04 or later) Number of DIMMs DIMM connectors 4 6 7 and 10 (largest DIMMs) 8 and 11 7 and 10 (largest DIMMs) 8 and 11 9 and 12 7 and 10 (largest DIMMs) 8 and 11 9 and 12 1 and 4 (dual-rank DIMMs only) 10 1 and 4 (largest DIMMs) 2 and 5 7 and 10 8 and 11 9 and 12 12 N/A N/A Online-sparing on branch 0 Online-sparing on branch 1 Results Online-sparing on branch 1 Online-sparing on branch 1 Online-sparing on branch 0 Online-sparing on branch 1 Online-sparing on branch 0 Online-sparing on branch 1 Results Online-sparing on branch 0 Online-sparing on branch 0
17
Filler panel
18
2.5-inch drives
To install a drive in a hot-swap bay, complete the following steps: Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each bay. 1. Read the safety information that begins on page v, and Installation guidelines on page 9. 2. Remove the filler panel from one of the empty hot-swap bays. 3. Install the hard disk drive in the hot-swap bay: a. Make sure that the tray handle is open (that is, perpendicular to the drive). b. Align the drive assembly with the guide rails in the bay. c. Gently push the drive assembly into the bay until the drive stops. d. Push the tray handle to the closed (locked) position. e. Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. Note: You might have to reconfigure the disk arrays after you install hard disk drives. See the RAID documentation on the IBM ServeRAID Support CD for information about RAID controllers. If you have other optional devices to install or remove, do so now. Otherwise, go to Completing the installation on page 32.
19
20
The following illustration shows how to install the second microprocessor on the system board.
21
Note: For simplicity, certain components are not shown in this illustration.
Microprocessor
Attention: v A startup (boot) processor must always be installed in microprocessor connector 1 on the system board. v To ensure correct server operation when you install an additional microprocessor, use microprocessors that have the same cache size and type, and the same clock speed. Microprocessor internal and external clock frequencies must be identical. To install an additional microprocessor, complete the following steps: 1. Read the safety information that begins on page v and Installation guidelines on page 9. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the server cover. Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling these devices, see Handling static-sensitive devices on page 11.
22
4. Remove the microprocessor air baffle. 5. Touch the static-protective package containing the VRM to any unpainted metal surface on the outside of the server. Then, remove the VRM from the package.
Alignment key
6. Turn the VRM so that the keys align correctly with the VRM connector; then, firmly press the VRM straight down into the connector. Make sure that the connector retaining clips are in the locked position. 7. Install the microprocessor: a. Touch the static-protective package that contains the microprocessor to any unpainted metal surface on the server. Then, remove the microprocessor from the package.
23
b. Remove the protective dust cover, tape, or label from the surface of the microprocessor socket, if one is present. c. Rotate the microprocessor release lever on the socket from its closed and locked position until it stops in the fully open position. Attention: v Handle the microprocessor carefully. Dropping the microprocessor during installation or removal can damage the contacts. Also, contaminants on the microprocessor contacts, such as oil from your skin, can cause connection failures between the contacts and the socket. v Do not use excessive force when you press the microprocessor into the socket. v Make sure that the microprocessor is correctly aligned and positioned in the socket before you try to close the lever.
Microprocessor
Alignment marks
Notches
d. Align the microprocessor with the socket (note the alignment mark and the position of the notches); then, carefully place the microprocessor on the socket. Close the microprocessor bracket frame. Note: The microprocessor fits only one way on the socket. e. Carefully close the microprocessor release lever to secure the microprocessor in the socket.
24
8. Install a heat sink on the microprocessor. Attention: Do not touch the thermal grease on the bottom of the heat sink or set down the heat sink after you remove the plastic cover. Touching the thermal grease will contaminate it. For details, see the information about thermal grease in the Users Guide on the IBM System x Documentation CD.
Thermal grease
Heat sink
a. Make sure that the heat-sink release lever is in the open position. b. Remove the plastic protective cover from the bottom of the heat sink. c. Align the heat sink above the microprocessor with the thermal grease side down.
Retainer bracket
d. Slide the rear flange of the heat sink into the opening in the retainer bracket. e. Press down firmly on the front of the heat sink until it is seated securely. f. Rotate the heat-sink release lever to the closed position and hook it underneath the lock tab. 9. Install the microprocessor air baffle. If you have other optional devices to install or remove, do so now. Otherwise, go to Completing the installation on page 32.
25
Installing an adapter
Adapter Riser-card assembly Expansion slot 1 Expansion slot 2 Expansion slot covers
Adapter
The following illustration shows the locations of the adapter expansion slots.
PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4
The following notes describe the types of adapters that the server supports and other information that you must consider when installing an adapter: v You can install only low-profile PCI Express adapters in PCI slots 3 and 4 on the system board. v You can install a full-height, half-length adapter in slot 2 on the PCI riser card and a full-height, full-length adapter in slot 1 on the PCI riser card. v An optional Remote Supervisor Adapter II SlimLine can be installed only in a dedicated slot on the system board. To install a Remote Supervisor Adapter II SlimLine, see Installing a Remote Supervisor Adapter II SlimLine on page 29. v The server supports only 3.3 V and universal PCI adapters. v The PCI bus configuration is as follows: Non-hot-plug, low-profile PCI Express x8 (x4 lanes), slot 4 Non-hot-plug, low-profile PCI Express x8 (x4 lanes), slot 3 Non-hot-plug, half-length PCI Express x8 (x8 lanes), slot 2 Non-hot-plug, full-length PCI Express x8 (x8 lanes), slot 1
26
Note: If you have replaced the PCI Express riser-card assembly with the optional PCI-X riser-card assembly, slots 1 and 2 are non-hot-plug, 64-bit, 133-MHz PCI-X slots, which support Integrated xSeries Adapter (IXA) single-width adapters. v The system scans devices in the following order, if you have not changed the default boot precedence: integrated Ethernet controllers, integrated SAS controller, and then PCI slots 1, 2, 3, and 4. PCI riser card The following illustration shows the location of the adapter expansion slots on the PCI riser card. Note: For clarity, the PCI riser-card assembly is inverted in the illustration.
PCI adapter connectors
To install an adapter, complete the following steps: 1. Read the safety information that begins on page v and Installation guidelines on page 9. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Determine which expansion slot you will use for the adapter. If you are installing an adapter in PCI slot 1 or 2, remove the PCI riser-card assembly.
27
Access holes
Release tabs
4. Slide the expansion-slot cover out of the PCI low-profile expansion slot or PCI riser-card assembly expansion slot. 5. Install the adapter. The following illustration shows how to install an adapter in a PCI slot on the riser-card assembly. Note: For clarity, the PCI riser-card assembly is shown inverted in the following illustration.
6. If you removed the PCI riser-card assembly to install the adapter, align the riser-card assembly with the release-tab posts, rear guides, and connector; then, press the PCI riser-card assembly firmly into the connector.
28
Access holes
7. Connect any required cables to the adapter. Attention: v When you route cables, do not block any connectors or the ventilated space around any of the fans. v Make sure that cables are not routed on top of components under the PCI riser-card assembly. v Make sure that cables are not pinched by the server components. 8. Perform any configuration tasks that are required for the adapter. If you have other optional devices to install, do so now. Otherwise, go to Completing the installation on page 32.
29
To install a Remote Supervisor Adapter II SlimLine, complete the following steps: 1. Read the safety information that begins on page v and Installation guidelines on page 9. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the cover. 4. Remove the PCI riser-card assembly. 5. Align the keys on the Remote Supervisor Adapter II SlimLine connector with the connector on the system board. 6. Slip the free end of the Remote Supervisor Adapter II SlimLine under the tab on the retainer bracket, aligning the holes in the adapter with the posts on the retainer bracket and latch bracket; then, press the adapter into the connector on the system board and make sure that all tabs on the latch bracket secure the adapter in place. 7. Replace the PCI riser-card assembly. See the documentation that comes with the Remote Supervisor Adapter II SlimLine for information about installing the firmware and configuring the adapter. Create a backup copy of the configuration so that if you have to replace the adapter in the future, you can restore the configuration. If you have other optional devices to install or remove, do so now. Otherwise, go to Completing the installation on page 32.
30
To replace the ServeRAID-8k-l SAS Controller with a ServeRAID-8k SAS Controller, complete the following steps: 1. Read the safety information that begins on page v and the Installation guidelines on page 9. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables (see Turning off the server on page 39). Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the cover (see Removing the cover on page 11). 4. Remove the riser-card assembly and the air baffle over the DIMMs. See the Users Guide for more information. 5. Locate the ServeRAID-8k-l SAS controller on the system board. Attention: To avoid breaking the retaining clips or damaging the connectors, handle the clips gently. 6. Open the retaining clip on each end of the connector. 7. Lift the ServeRAID-8k-l SAS controller out of the connector. 8. Touch the static-protective package that contains the new ServeRAID-8k SAS controller to any unpainted metal surface on the server. Then, remove the ServeRAID-8k SAS controller from the package.
Battery Battery cable
RAID controller
9. Turn the new ServeRAID-8k SAS controller so that the keys on the bottom edge align correctly with the connector. 10. Firmly press the ServeRAID-8k SAS controller straight down into the connector by applying pressure on both ends of the controller simultaneously. The retaining clips snap into the locked position when the controller is firmly seated in the connector.
31
Note: If there is a gap between the controller and the retaining clips, the controller has not been correctly installed. In this case, open the retaining clips and remove the controller; then, reinsert the controller. 11. Remove the battery from the ServeRAID-8k SAS Controller package. 12. Slide the battery mounting tabs into the battery mounting clips on the server wall that is next to the ServeRAID SAS controller connector. 13. Connect the battery to the ServeRAID-8k SAS Controller. 14. Replace the air baffle over the DIMMs. See the Users Guide for more information. 15. Replace the riser-card assembly. If you have other optional devices to install or remove, do so now. Otherwise, go to Completing the installation. Notes: 1. When you restart the server for the first time after you install a ServeRAID-8k SAS controller, the monitor screen remains blank while the controller initializes the battery. This might take a few minutes, after which the startup process continues. This is a one-time occurrence. Important: You must allow the initialization process to be completed. If you do not, the battery pack will not work, and the server might not start. The battery comes partially charged, at 30% or less of capacity. Run the server for 4 to 6 hours to fully charge the controller battery. The LED just above the battery on the controller remains lit until the battery is fully charged. Until the battery is fully charged, the controller firmware sets the controller cache to write-through mode; after the battery is fully charged, the controller firmware re-enables write-back mode. 2. When you restart the server, you will be given the opportunity to import the existing RAID configuration to the new ServeRAID SAS controller.
32
Cover-release latch
Rear view
Systems-management Ethernet connector Power-cord connector
SAS connector
Serial connector
USB 1 USB 3 connector connector Video Ethernet 2 connector connector USB 2 connector
Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply for instructions and an illustration of the dc power supply.
Chapter 2. Installing optional devices
33
You must turn off the server before you connect or disconnect cables from the server. See the documentation that comes with any external devices for additional cabling instructions. It might be easier for you to route cables before you connect the devices to the server. Cable identifiers are printed on the cables that come with the server and optional devices. Use these identifiers to connect the cables to the correct connectors.
34
Front view
The following illustration shows the controls, light-emitting diodes (LEDs), and connectors on the front of the 3.5-inch model server.
Operator information panel USB 5 connector USB 6 connector Video connector Hard disk drive activity LED (green) Hard disk drive status LED (amber)
CD/DVD eject button CD/DVD drive activity LED Rack release latch Rack release latch
The following illustration shows the controls, light-emitting diodes (LEDs), and connectors on the front of the 2.5-inch model server.
Operator information panel USB 5 connector USB 6 connector Video connector Tape drive bay Hard disk drive activity LED (green) Hard disk drive status LED (amber)
CD/DVD eject button CD/DVD drive activity LED Rack release latch Rack release latch
Operator information panel: This panel contains controls, LEDs, and connectors. The following illustration shows the controls, LEDs, and connectors on the operator information panel.
35
Power-on LED
Information LED
Release latch
Power-control button
System-error LED
The following controls, LEDs, and connectors are on the operator information panel: v Power-control button: Press this button to turn the server on and off manually. A power-control-button shield comes installed on the server to prevent the server from being turned off accidentally. v Power-on LED: When this LED is lit and not flashing, it indicates that the server is turned on. When this LED is flashing, it indicates that the server is turned off and still connected to a power source. When this LED is off, it indicates that power is not present, or the power supply or the LED itself has failed. Note: If this LED is off, it does not mean that there is no electrical power in the server. The LED might be burned out. To remove all electrical power from the server, you must disconnect the power cord from the electrical outlet. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. v Hard disk drive activity LED: When this LED is flashing, it indicates that a hard disk drive is in use. v System-locator LED: Use this LED to visually locate the server among other servers. You can use IBM Director to light this LED remotely. v Information LED: When this LED is lit, it indicates that a noncritical event has occurred. An LED on the light path diagnostics panel is also lit to help isolate the error. v System-error LED: When this LED is lit, it indicates that a system error has occurred. An LED on the light path diagnostics panel is also lit to help isolate the error. v Release latch: Slide this latch to the left to access the light path diagnostics panel, which is behind the operator information panel. USB connectors: Connect a USB device, such as USB mouse, keyboard, or other USB device, to either of these connectors. Video connector: Connect a monitor to this connector. The video connectors on the front and rear of the server can be used simultaneously. Hard disk drive activity LED: Each hot-swap hard disk drive has an activity LED. When this LED is flashing, it indicates that the drive is in use. Hard disk drive status LED: On some server models, each hot-swap hard disk drive has a status LED. When this LED is lit, it indicates that the drive has failed. When this LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt as part of a RAID configuration. When the LED is flashing rapidly (three flashes per second), it indicates that the controller is identifying the drive.
36
CD/DVD-eject button: Press this button to release a CD or DVD from the CD-RW/DVD drive. CD/DVD drive activity LED: When this LED is lit, it indicates that the CD-RW/DVD drive is in use. Rack release latches: Press these latches to release the server from the rack.
Rear view
The following illustration shows the connectors and LEDs on the rear of the server. Attention: In a dc power environment, see the documentation that comes with the dc power supply for information about the power-supply LEDs.
AC power LED DC power LED Power-cord Power-supply connector filler panel Systems-management Ethernet connector Ethernet activity LEDs Ethernet link LEDs
Power supply 1
SAS connector
Serial USB 1 USB 3 connector connector connector Video Ethernet 2 Power-on LED connector System-locator LED connector USB 2 System-error LED connector
Power-cord connector (ac power supply only): Connect the power cord to this connector. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. AC power LED: Each hot-swap power supply has an ac power LED and a dc power LED. When the ac power LED is lit, it indicates that sufficient power is coming into the power supply through the power cord. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Problem Determination and Service Guide on the IBM System x Documentation CD. DC power LED: Each hot-swap power supply has a dc power LED and an ac power LED. When the dc power LED is lit, it indicates that the power supply is supplying adequate DC power to the system. During typical operation, both the ac and dc power LEDs are lit. For any other combination of LEDs, see the Problem Determination and Service Guide on the IBM System x Documentation CD. Systems-management Ethernet connector: Use this connector to connect the server to a network for systems-management information control. This connector is active only if you have installed a Remote Supervisor Adapter II SlimLine, and it is used only by the Remote Supervisor Adapter II SlimLine.
37
Ethernet activity LEDs: When these LEDs are lit, they indicate that the server is transmitting to or receiving signals from the Ethernet LAN that is connected to the Ethernet port. Ethernet link LEDs: When these LEDs are lit, they indicate that there is an active link connection on the 10BASE-T, 100BASE-TX, or 1000BASE-TX interface for the Ethernet port. Ethernet connectors: Use either of these connectors to connect the server to a network. USB connectors: Connect a USB device, such as USB mouse, keyboard, or other USB device, to any of these connectors. Video connector: Connect a monitor to this connector. The video connectors on the front and rear of the server can be used simultaneously. System-error LED: When this LED is lit, it indicates that a system error has occurred. An LED on the light path diagnostics panel is also lit to help isolate the error. System-locator LED: Use this LED to visually locate the server among other servers. You can use IBM Director to light this LED remotely. Power-on LED: When this LED is lit and not flashing, it indicates that the server is turned on. When this LED is flashing, it indicates that the server is turned off and still connected to a power source. When this LED is off, it indicates that power is not present, or the power supply or the LED itself has failed. Serial connector: Connect a 9-pin serial device to this connector. The serial port is shared with the baseboard management controller (BMC). The BMC can take control of the shared serial port to perform text console redirection and to redirect serial traffic, using Serial over LAN (SOL). SAS connector: Connect a serial-attached SCSI (SAS) device to this connector.
38
The server can also be turned on in any of the following ways: v If a power failure occurs while the server is turned on, the server will restart automatically when power is restored. v If your operating system supports the Wake on LAN feature, the Wake on LAN feature can turn on the server. Note: When 4 GB or more of memory (physical or logical) is installed, some memory is reserved for various system resources and is unavailable to the operating system. The amount of memory that is reserved for system resources depends on the operating system, the configuration of the server, and the configured PCI options.
CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
2 1
Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply.
39
The server can be turned off in any of the following ways: v You can turn off the server from the operating system, if your operating system supports this feature. After an orderly shutdown of the operating system, the server will be turned off automatically. v You can press the power-control button to start an orderly shutdown of the operating system and turn off the server, if your operating system supports this feature. v If the operating system stops functioning, you can press and hold the power-control button for more than 4 seconds to turn off the server. v The service processor can turn off the server as an automatic response to a critical system failure. v You can turn off the server through a request from the service processor.
40
41
v Set and change the startup characteristics of the server and the order of startup devices (startup-drive sequence) v Set and change settings for advanced hardware features v View and clear the error log v Change interrupt request (IRQ) settings v Resolve configuration conflicts To start the Configuration/Setup Utility program, complete the following steps: 1. Turn on the server. 2. When the message Press F1 for Configuration/Setup appears, press F1. If an administrator password has been set, you must type the administrator password to access the full Configuration/Setup Utility menu. 3. Follow the instructions on the screen.
42
43
To run ServeRAID Manager in Startable CD mode, turn on the server; then, insert the CD into the CD-RW/DVD drive. If ServeRAID Manager detects an unconfigured controller and ready drives, the Configuration wizard starts. In the Configuration wizard, you can select express configuration or custom configuration. Express configuration automatically configures the controller by grouping the first two physical drives in the ServeRAID Manager tree into an array and creating a RAID level-1 logical drive. If you select custom configuration, you can select the two physical drives that you want to group into an array and create a hot-spare drive. Using express configuration: To use express configuration, complete the following steps: 1. In the ServeRAID Manager tree, click the controller. 2. Click Express configuration. 3. Click Next. 4. In the Configuration summary window, review the information. To change the configuration, click Modify arrays. 5. Click Apply; when you are asked whether you want to apply the new configuration, click Yes. The configuration is saved in the controller and in the physical drives. 6. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD drive. 7. Restart the server. Using custom configuration: To use custom configuration, complete the following steps: 1. In the ServeRAID Manager tree, click the controller. 2. Click Custom configuration. 3. Click Next. 4. In the Create arrays window, from the list of ready drives, select the drives that you want to group into the array. 5. Click the (Add selected drives) icon to add the drives to the array. 6. If you want to configure a hot-spare drive, complete the following steps: a. Click the Spares tab. b. Select the physical drive that you want to designate as the hot-spare drive, and click the (Add selected drives) icon. 7. Click Next. 8. Review the information in the Configuration summary window. To change the configuration, click Back. 9. Click Apply; when you are asked whether you want to apply the new configuration, click Yes. The configuration is saved in the controller and in the physical drives. 10. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD drive. 11. Restart the server.
44
drives). When you click an object in the ServeRAID Manager tree, information about that object appears in the right pane. To display a list of available actions for an object, click the object and click Actions.
Enabling and configuring SOL using the OSA SMBridge management utility program
To enable and configure the server for SOL by using the OSA SMBridge management utility program, you must update and configure the BIOS code; update and configure the baseboard management controller (BMC) firmware; update and configure the Ethernet controller firmware; and enable the operating system for an SOL connection.
45
a. Download the latest version of the BMC firmware from http://www.ibm.com/ systems/support/. b. Update the BMC firmware, following the instructions that come with the update file that you downloaded. 3. Configure the BIOS settings: a. When you are prompted to start the Configuration/Setup Utility program, restart the server and press F1. b. Select Devices and I/O Ports; then, make sure that the values are set as follows: v Serial Port A: Auto-configure v Serial Port B: Auto-configure c. Select Remote Console Redirection; then, make sure that the values are set as follows: v Remote Console Active: Enabled v Remote Console COM Port: COM 1 v Remote Console Baud Rate: 19200 or higher v v v v v v v Remote Remote Remote Remote Remote Remote Remote Console Data Bits: 8 Console Parity: None Console Stop Bits: 1 Console Text Emulation: ANSI Console Keyboard Emulation: ANSI Console Active After Boot: Enabled Console Flow Control: Hardware
d. Press Esc twice to exit the Remote Console Redirection and Devices and I/O Ports sections of the Configuration/Setup Utility program. e. Select Advanced Setup; then, select Baseboard Management Controller (BMC) Settings. f. Set BMC Serial Port Access Mode to Dedicated. g. Press Esc twice to exit the Baseboard Management Controller (BMC) Settings and Advanced Setup sections of the Configuration/Setup Utility program. h. Select Save Settings; then, press Enter. i. Press Enter to confirm. j. Select Exit Setup; then, press Enter. k. Make sure that Yes, exit the Setup Utility is selected; then, press Enter.
Linux configuration
For SOL operation on the server, you must configure the Linux operating system to expose the Linux initialization (booting) process. This enables users to log in to the Linux console through an SOL session and directs Linux output to the serial console. See the documentation for your specific Linux operating-system type for information and instructions. Use one of the following procedures to enable SOL sessions for your Linux operating system. You must be logged in as a root user to perform these procedures. Red Hat Enterprise Linux ES 4 configuration:
46
Note: This procedure is based on a default installation of Red Hat Enterprise Linux ES 4. The file names, structures, and commands might be different for other versions of Red Hat Linux. To configure the general Linux parameters for SOL operation when you are using the Red Hat Enterprise Linux ES 4 operating system, complete the following steps. Note: Hardware flow control prevents character loss during communication over a serial connection. You must enable it when you are using a Linux operating system. 1. Add the following line to the end of the # Run gettys in standard runlevels section of the /etc/inittab file. This enables hardware flow control and enables users to log in through the SOL console.
7:2345:respawn:/sbin/agetty -h ttyS0 19200 vt102
2. Add the following line at the bottom of the /etc/securetty file to enable a user to log in as the root user through the SOL console:
ttyS0
LILO configuration: If you are using LILO, complete the following steps: 1. Modify the /etc/lilo.conf file: a. Add the following text to the end of the first default=linux line
-Monitor
b. Comment out the map=/boot/map line by adding a # at the beginning of this line. c. Comment out the message=/boot/message line by adding a # at the beginning of this line. d. Add the following line before the first image= line:
# This will allow you to only Monitor the OS boot via SOL
e. Add the following text to the end of the first label=linux line:
-Monitor
f. Add the following line to the first image= section. This enables SOL.
append="console=ttyS0,19200n8 console=tty1"
The following examples show the original content of the /etc/lilo.conf file and the content of this file after modification.
47
Original /etc/lilo.conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.b message=/boot/message linear image=/boot/vmlinuz-2.4.9-e.12smp label=linux initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 image=/boot/vmlinuz-2.4.9-e.12 label=linux-up initrd=/boot/initrd-2.4.9-e.12.img read-only root=/dev/hda6
48
Modified /etc/lilo.conf contents prompt timeout=50 default=linux-Monitor boot=/dev/hda #map=/boot/map install=/boot/boot.b #message=/boot/message linear # This will allow you to only Monitor the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Monitor initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 append="console=ttyS0,19200n8 console=tty1" # This will allow you to Interact with the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Interact initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 append="console=tty1 console=ttyS0,19200n8 " image=/boot/vmlinuz-2.4.9-e.12 label=linux-up initrd=/boot/initrd-2.4.9-e.12.img read-only root=/dev/hda6
2. Run the lilo command to store and activate the LILO configuration. When the Linux operating system starts, a LILO boot: prompt is displayed instead of the graphical user interface. Press Tab at this prompt to install all of the boot options that are listed. To load the operating system in interactive mode, type linux-Interact and then press Enter. GRUB configuration: If you are using GRUB, complete the following steps to modify the /boot/grub/grub.conf file: 1. Comment out the splashimage= line by adding a # at the beginning of this line. 2. Add the following line before the first title= line:
# This will allow you to only Monitor the OS boot via SOL
4. Append the following text to the kernel/ line of the first title= section:
console=ttyS0,19200 console=tty1
5. Add the following five lines between the two title= sections:
# This will allow you to Interact with the OS boot via SOL title Red Hat Linux (2.4.9-e.12smp) SOL Interactive root (hd0,0)
Chapter 4. Configuring the server
49
Note: The entry that begins with kernel /vmlinuz is shown with a line break after console=tty1. In your file, the entire entry must all be on one line. The following examples show the original content of the /boot/grub/grub.conf file and the content of this file after modification.
Original /boot/grub/grub.conf contents #grub.conf generated by anaconda # # Note that you do not have to rerun grub after making changes to this file # NOTICE: # # # # default=0 timeout=10 splashimage=(hd0,0)/grub/splash.xpm.gz title Red Hat Enterprise Linux ES (2.4.9-e.12smp) root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 initrd /initrd-2.4.9-e.12smp.img title Red Hat Enterprise Linux ES-up (2.4.9-e.12) root (hd0,0) kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6 initrd /initrd-2.4.9-e.12.img You have a /boot partition. root (hd0,0) kernel /vmlinuz-version ro root=/dev/hda6 initrd /initrd-version.img This means that all kernel and initrd paths are relative to /boot/, eg.
#boot=/dev/hda
50
Modified /boot/grub/grub.conf contents #grub.conf generated by anaconda # # Note that you do not have to rerun grub after making changes to this file # NOTICE: # # # # default=0 timeout=10 # splashimage=(hd0,0)/grub/splash.xpm.gz # This will allow you to only Monitor the OS boot via SOL title Red Hat Enterprise Linux ES (2.4.9-e.12smp) SOL Monitor root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=ttyS0,19200 console=tty1 initrd /initrd-2.4.9-e.12smp.img # This will allow you to Interact with the OS boot via SOL title Red Hat Linux (2.4.9-e.12smp) SOL Interactive root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 console=ttyS0,19200 initrd /initrd-2.4.9-e.12smp.img title Red Hat Enterprise Linux ES-up (2.4.9-e.12) root (hd0,0) kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6 initrd /initrd-2.4.9-e.12.img You have a /boot partition. root (hd0,0) kernel /vmlinuz-version ro root=/dev/hda6 initrd /initrd-version.img This means that all kernel and initrd paths are relative to /boot/, eg.
#boot=/dev/hda
You must restart the Linux operating system after you complete these procedures for the changes to take effect and to enable SOL. SUSE SLES 9.0 configuration: Note: This procedure is based on a default installation of SUSE Linux Enterprise Server (SLES) 9.0. The file names, structures, and commands might be different for other versions of SUSE Linux. To configure the general Linux parameters for SOL operation when using the SLES 9.0 operating system, complete the following steps. Note: Hardware flow control prevents character loss during communication over a serial connection. You must enable it when using a Linux operating system. 1. Add the following line to the end of the # getty-programs for the normal runlevels section of the /etc/inittab file. This enables hardware flow control and enables users to log in through the SOL console.
7:2345:respawn:/sbin/agetty -h ttyS0 19200 vt102
2. Add the following line after the tty6 line at the bottom of the /etc/securetty file to enable a user to log in as the root user through the SOL console:
ttyS0
51
a. Comment out the gfxmenu line by adding a # in front of the word gfxmenu. b. Add the following line before the first title line:
# This will allow you to only Monitor the OS boot via SOL
d. Append the following text to the kernel line of the first title section:
console=ttyS1,19200 console=tty0
e. Add the following four lines between the first two title sections:
# This will allow you to Interact with the OS boot via SOL title linux SOL Interactive kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=tty1 console=ttyS0,19200 initrd (hd0,1)/boot/initrd
The following examples show the original content of the /boot/grub/menu.lst file and the content of this file after modification.
Original /boot/grub/menu.lst contents gfxmanu (hd0,1)/boot/message color white/blue black/light-gray default 0 timeout 8 title linux kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 initrd (hd0,1)/boot/initrd title floppy root chainloader +1 title failsafe kernal (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.shipped Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line. Notes
Modified /boot/grub/menu.lst contents #gfxmanu (hd0,1)/boot/message color white/blue black/light-gray default 0 timeout 8 # This will allow you to only Monitor the OS boot via SOL title linux SOL Monitor kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=ttyS1,19200 console=tty1 initrd (hd0,1)/boot/initrd # This will allow you to Interact with the OS boot via SOL title linux SOL Interactive kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=tty1 console=ttyS0,19200 initrd (hd0,1)/boot/initrd title floppy
Notes
52
Modified /boot/grub/menu.lst contents root chainloader +1 title failsafe kernel (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.shipped Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line.
Notes
You must restart the Linux operating system after you complete these procedures for the changes to take effect and to enable SOL.
where boot_id is the boot entry ID from step 1b; then, press Enter. 3. Complete the following steps to verify that the EMS console is redirected to the COM1 serial port: a. Type bootcfg at a Windows command prompt; then, press Enter to display the current boot options for your server. b. Verify the following changes to the bootcfg settings: v In the Boot Loader Settings section, make sure that redirect is set to COM1 and that redirectbaudrate is set to 19200. v In the Boot Entries section, make sure that the OS Load Options: line has /redirect appended to the end of it. The following examples show the original bootcfg program output and the output after modification.
53
Original bootcfg program output Boot Loader Settings ---------------------------timeout: 30 default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS Boot Entries ---------------Boot entry ID: 1 OS Friendly Name: Windows Server 2003, Standard Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS OS Load Options: /fastdetect
Modified bootcfg program output Boot Loader Settings ---------------------------timeout: 30 default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS redirect: COM1 redirectbaudrate: 19200 Boot Entries ---------------Boot entry ID: 1 OS Friendly Name: Windows Server 2003, Standard Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS OS Load Options: /fastdetect /redirect
You must restart the Windows 2003 operating system after you complete this procedure for the changes to take effect and to enable SOL.
54
3. Follow the prompts to complete the installation. The installation program prompts you for a TCP/IP port number and an IP address. Specify an IP address, if you want to limit the connection requests that will be accepted by the utility program. To accept connections from any server, type INADDR_ANY as the IP address. Also specify the port number that the utility program will use. These values will be recorded in the smbridge.cfg file for the automatic startup of the utility program. To install the OSA SMBridge management utility program on a server running a Linux operating system, complete the following steps. You must be logged in as a root user to perform these procedures. 1. Go to http://www.ibm.com/systems/support/. Download the utility program and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the drive. 3. Type mount/mnt/cdrom. 4. Locate the directory where the installation RPM package is located and type cd/mnt/cdrom. 5. Type the following command to run the RPM package and start the installation:
rpm -ivh smbridge-2.0-xx.rpm
where xx is the release level being installed. 6. Follow the prompts to complete the installation. When the installation is complete, the utility copies files to the following directories: /etc/init.d/SMBridge /etc/smbridge.cfg /usr/sbin/smbridged /var/log/smbridge/Liscense.txt /var/log/smbridge/Readme.txt
55
The utility starts automatically when the server is started. You can also locate the /ect/init.d directory to start the utility and use the following commands to manage the utility: smbridge status smbridge start smbridge stop smbridge restart
56
v CLI (command-line interface) mode Use CLI mode to remotely perform power-management and system identification control functions over a LAN or serial port interface from a command-line interface. Use CLI mode also to remotely view the BMC system event log. Use the following commands in CLI mode: identify Control the system-locator LED on the front of the server. power Turn the server on and off remotely. sel Perform operations with the BMC system event log. sysinfo Display general system information that is related to the server and the baseboard management controller. v Serial over LAN Use the Serial over LAN capability to remotely perform control and management functions over a Serial over LAN (SOL) network. You can also use SOL to remotely view and change the server BIOS settings. At a command prompt, type telnet localhost 623 to access the SOL network. Type help at the smbridge> prompt for more information. Use the following commands in an SOL session: connect Connect to the LAN. Type connect -ip ip_address -u username -p password. identify Control the system-locator LED on the front of the server. power Turn the server on and off remotely. reboot Force the server to restart. sel get Display the BMC system event log. sol Configure the SOL function. sysinfo Display system information that is related to the server and the globally unique identifier (GUID).
57
58
59
162
A device configuration v Run the Configuration/Setup Utility program, has changed. select Load Default Settings, and save the settings. v Make sure that optional devices are turned on and installed correctly. The time of day has not been set. A failing DIMM was disabled. Keyboard and keyboard controller PCI device error Run the Configuration/Setup Utility program and set the date and time. Make sure that the DIMMs are supported by the server and that they are installed correctly. Make sure that the keyboard cable is connected and that nothing is resting on the keyboard keys. Make sure that all PCI adapters are installed correctly. In the Configuration/Setup Utility program, make sure that all PCI devices are enabled. Disable option ROMs and integrated devices that are not needed and set the PCI device boot priority to ensure that the boot device option ROM is able to load. Install an operating system. Make sure that microprocessor x is installed correctly. (Trained service technician only) If the problem remains, replace microprocessor x. Download and install the latest level of BIOS code.
1962 00019xxx
POST could not find an operating system. Microprocessor x is not functioning or failed the built-in self-test. Data for microprocessor x
012980xx 012981xx
60
ServerGuide problems
The following table lists problem symptoms and suggested solutions.
Table 8. ServerGuide Setup and Installation CD Symptom The ServerGuide Setup and Installation CD will not start. Suggested action 1. Make sure that the server supports the ServerGuide program and has a startable (bootable) CD-RW/DVD drive. 2. If the startup (boot) sequence settings have been changed, make sure that the CD-RW/DVD drive is first in the startup sequence. 3. If more than one CD or DVD drive is installed, make sure that only one drive is set as the primary drive. Start the CD from the primary drive.
The ServeRAID program cannot 1. Make sure that there are no duplicate IRQ assignments. view all installed drives, or the 2. Make sure that the hard disk drive is connected correctly. operating system cannot be 3. Make sure that the hard disk drive cables are securely connected. installed. The operating-system installation program continuously loops. The ServerGuide program will not start the operating-system CD. Make more space available on the hard disk.
Make sure that the operating-system CD is supported by the ServerGuide program. See the ServerGuide Setup and Installation CD label for a list of supported operating-system versions
The operating system cannot be Make sure that the operating system is supported on the server. If the operating installed; the option is not system is supported, there is no logical drive defined (SAS RAID systems. Run the available. ServerGuide program and make sure that setup is complete.
61
Troubleshooting tables
Use the troubleshooting tables to find solutions to problems that have identifiable symptoms. See the Problem Determination and Service Guide on the IBM System x Documentation CD for more detailed troubleshooting information. If you cannot find the problem in these tables, run the diagnostic programs (see Running the diagnostic programs in the Problem Determination and Service Guide). If you have just added new software or a new optional device and the server is not working, complete the following steps before using the troubleshooting tables: 1. Check the light path diagnostics LEDs on the operator information panel (see Light path diagnostics on page 74). 2. Remove the software or device that you just added. 3. Run the diagnostic tests to determine whether the server is running correctly. 4. Reinstall the new software or new device.
62
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom The CD-RW/DVD drive tray is not working. Action 1. Make sure that the server is turned on. 2. Insert the end of a straightened paper clip into the manual tray-release opening. 3. Reseat the CD-RW/DVD drive. 4. Replace the CD-RW/DVD drive.
General problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom A cover lock is broken, an LED is not working, or a similar problem has occurred. Action If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a trained service technician.
Not all drives are recognized by Remove the drive that is indicated by the diagnostic tests; then, run the hard disk the hard disk drive diagnostic drive diagnostic test again. If the remaining drives are recognized, replace the drive test (the Fixed Disk test). that you removed with a new one. The server stops responding during the hard disk drive diagnostic test. A hard disk drive was not detected while the operating system was being started. A hard disk drive passes the diagnostic Fixed Disk Test, but the problem remains. Remove the hard disk drive that was being tested when the server stopped responding, and run the diagnostic test again. If the hard disk drive diagnostic test runs successfully, replace the drive that you removed with a new one. Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic tests again. Run the diagnostic SCSI Attached Disk Test.
63
Intermittent problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom A problem occurs only occasionally and is difficult to diagnose. Action 1. Make sure that: v All cables and cords are connected securely to the rear of the server and attached devices. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. v When the server is turned on, air is flowing from the fan grille. If there is no airflow, the fans are not working. This can cause the server to overheat and shut down. 2. Check the system event/error log or BMC system event log (see Error Logs in the Problem Determination and Service Guide). The server resets (restarts) occasionally 1. If the reset occurs during POST and the POST watchdog timer is enabled (click Advanced Setup --> Baseboard Management Controller (BMC) Setting --> BMC Post Watchdog in the Configuration/Setup Utility program to see the POST watchdog setting), make sure that sufficient time is allowed in the watchdog timeout value (BMC POST Watchdog Timeout). See the Users Guide for information about the settings in the Configuration/Setup Utility program. If the server continues to reset during POST, see the POST and Diagnostic programs sections in the Problem Determination and Service Guide. 2. If the reset occurs after the operating system starts, disable any automatic server restart (ASR) utilities, such as the IBM Automatic Server Restart IPMI Application for Windows, or ASR devices that may be installed. Note: ASR utilities operate as operating-system utilities and are related to the IPMI device driver. If the reset continues to occur after the operating system starts, the operating system might have a problem; see Software problems on page 73. 3. If neither condition applies, check the system event/error log or BMC system event log (see Error Logs in the Problem Determination and Service Guide).
64
65
Memory problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom Action
The amount of system memory 1. Make sure that: that is displayed is less than the v No error LEDs are lit on the operator information panel. amount of installed physical v Memory mirroring or memory sparing does not account for the discrepancy. memory. v The memory modules are seated correctly. v You have installed the correct type of memory (see Installing a memory module on page 12). v If you changed the memory, you updated the memory configuration in the Configuration/Setup Utility program. v All banks of memory are enabled. The server might have automatically disabled a memory bank when it detected a problem, or a memory bank might have been manually disabled. 2. Check the POST error log for error message 289: v If a DIMM was disabled by a system-management interrupt (SMI), replace the DIMM. v If a DIMM was disabled by the user or by POST, run the Configuration/Setup Utility program and enable the DIMM. 3. Run memory diagnostics (see Running the diagnostic programs in the Problem Determination and Service Guide). 4. Make sure that there is no memory mismatch when the server is at the minimum memory configuration (two 512 MB DIMMs). 5. Add one pair of DIMMs at a time, making sure that the DIMMs in each pair are matching. Install the DIMMs in the sequence that is described in Installing a memory module on page 12. 6. Reseat the DIMMs. 7. Replace the following components one at a time, in the order shown, restarting the server each time: a. DIMMs b. (Trained service technician only) System board Multiple rows of DIMMs in a branch are identified as failing. 1. Reseat the DIMMs; then, restart the server. 2. Replace the lowest-numbered DIMM pair of those that are identified; then, restart the server. Repeat as necessary. 3. (Trained service technician only) Replace the system board.
66
Microprocessor problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom The server emits a continuous beep during POST, indicating that the microprocessor is not working correctly. Action 1. Correct any errors that are indicated by the LEDs (see Light path diagnostics LEDs in the Problem Determination and Service Guide). 2. Make sure that the server supports all the microprocessors and that the microprocessors match in speed and cache size. 3. (Trained service technician only) Make sure that microprocessor 1 is seated correctly. 4. Reseat the following components: a. (Trained service technician only) Microprocessors b. VRM, if microprocessor 2 is installed 5. (Trained service technician only) Replace the microprocessors.
67
Monitor problems
Some IBM monitors have their own self-tests. If you suspect a problem with your monitor, see the documentation that comes with the monitor for instructions for testing and adjusting the monitor. If you cannot diagnose the problem, call for service.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom Testing the monitor Action 1. Make sure that the monitor cables are firmly connected. 2. Try using the other video port. 3. Try using a different monitor on the server, or try testing the monitor on a different server. 4. Run the diagnostic programs (see the Problem Determination and Service Guide). If the monitor passes the diagnostic programs, the problem might be a video device driver. 5. Reseat the Remote Supervisor Adapter II SlimLine (if one is present). 6. Replace the following components one at a time, in the order shown, restarting the server each time: a. Remote Supervisor Adapter II SlimLine (if one is present) b. (Trained service technician only) System board The screen is blank. 1. If the server is attached to a KVM switch, bypass the KVM switch to eliminate it as a possible cause of the problem: connect the monitor cable directly to the correct connector on the rear of the server. 2. Make sure that: v The server is turned on. If there is no power to the server, see Power problems on page 70. v The monitor cables are connected correctly. v The monitor is turned on and the brightness and contrast controls are adjusted correctly. v No beep codes sound when the server is turned on. Important: In some memory configurations, the 3-3-3 beep code might sound during POST, followed by a blank monitor screen. If this occurs and the Boot Fail Count option in the Start Options of the Configuration/Setup Utility program is enabled, you must restart the server three times to reset the configuration settings to the default configuration (the memory connector or bank of connectors enabled). 3. Make sure that the correct server is controlling the monitor, if applicable. 4. Make sure that damaged BIOS code is not affecting the video; see the Problem Determination and Service Guide for information about recovering from a BIOS failure. 5. See the Problem Determination and Service Guide for information about solving undetermined problems.
68
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom The monitor works when you turn on the server, but the screen goes blank when you start some application programs. Action 1. Make sure that: v The application program is not setting a display mode that is higher than the capability of the monitor. v You installed the necessary device drivers for the application. 2. Run video diagnostics (see the Problem Determination and Service Guide for information about running the diagnostic programs). v If the server passes the video diagnostics, the video is good; see the Problem Determination and Service Guide for information about solving undetermined problems. The monitor has screen jitter, or 1. If the monitor self-tests show that the monitor is working correctly, consider the the screen image is wavy, location of the monitor. Magnetic fields around other devices (such as unreadable, rolling, or distorted. transformers, appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy, unreadable, rolling, or distorted screen images. If this happens, turn off the monitor. Attention: Moving a color monitor while it is turned on might cause screen discoloration. Move the device and the monitor at least 305 mm (12 in.) apart, and turn on the monitor. Notes: a. To prevent diskette drive read/write errors, make sure that the distance between the monitor and any external diskette drive is at least 76 mm (3 in.). b. Non-IBM monitor cables might cause unpredictable problems. 2. Reseat the following components: a. Monitor cable b. Remote Supervisor Adapter II SlimLine (if one is present) 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Monitor cable b. Monitor c. Remote Supervisor Adapter II SlimLine (if one is present) d. (Trained service technician only) System board Wrong characters appear on the 1. If the wrong language is displayed, update the BIOS code with the correct screen. language. 2. Reseat the monitor cable. 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Monitor b. (Trained service technician only) System board
69
Optional-device problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom Action
An IBM optional device that was 1. Make sure that: just installed does not work. v The device is designed for the server (see http://www.ibm.com/servers/ eserver/serverproven/compat/us/). v You followed the installation instructions that came with the device and the device is installed correctly. v You have not loosened any other installed devices or cables. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. v You updated the configuration information in the Configuration/Setup Utility program. Whenever memory or any other device is changed, you must update the configuration. 2. Reseat the device that you just installed. 3. Replace the device that you just installed. An IBM optional device that used to work does not work now. 1. Make sure that all of the hardware and cable connections for the device are secure. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 2. If the device comes with test instructions, use those instructions to test the device. 3. Reseat the failing device. 4. Follow the instructions for device maintenance, such as keeping the heads clean, and troubleshooting in the documentation that comes with the device. 5. Replace the failing device.
Power problems
Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply.
70
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom Action
The power-control button does 1. Make sure that: not work, and the reset button v The power cords are correctly connected to the server and to a working does work (the server does not power source. start). Attention: In a dc power environment, only trained service personnel Note: The power-control button other than IBM service technicians are authorized to connect or disconnect will not function until 20 power to the dc power supply. See the documentation that comes with each seconds after the server has dc power supply. been connected to power. v The type of memory that is installed is correct. v The LEDs on the power supply do not indicate a problem. v The microprocessors are installed in the correct sequence. 2. Make sure that the power-control button and the reset button are working correctly: Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. a. Disconnect the server power cords. b. Reseat the operator information panel assembly cable. c. Reconnect the power cords. d. Press the power-control button to restart the server. If the button does not work, replace the operator information panel assembly. e. Press the reset button (on the light path diagnostics panel) to restart the server. If the button does not work, replace the operator information panel assembly. 3. If you just installed an optional device, remove it, and restart the server. If the server now starts, you might have installed more devices than the power supply supports. 4. Reseat the power backplane and restart the server. 5. Replace the power backplane and restart the server. 6. Replace the following components one at a time, in the order shown, restarting the server each time: a. Power supplies Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to remove and install the dc power supply. See the documentation that comes with each dc power supply. b. (Trained service technician only) System board 7. See Solving power problems and Solving undetermined problems in the Problem Determination and Service Guide.
71
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom The server does not turn off. Action 1. Turn off the server by pressing the power-control button for 5 seconds. 2. Restart the server. 3. If the server fails POST and the power-control button does not work, disconnect the power cord for 20 seconds; then, reconnect the power cord and restart the server. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 4. If the problem remains, suspect the system board. The OVER SPEC LED on the light path diagnostics panel is lit, and the one of the power channel LEDs on the system board is lit. The server unexpectedly shuts down, and the LEDs on the operator information panel are not lit. See the power troubleshooting table in the Problem Determination and Service Guide or call for service.
See Solving undetermined problems in the Problem Determination and Service Guide.
72
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom A serial device does not work. Action 1. Make sure that: v The device is compatible with the server. v The serial port is enabled and is assigned a unique address. v The device is connected to the correct connector (see Rear view on page 37). 2. Reseat the following components: a. Failing serial device b. Serial cable c. Remote Supervisor Adapter II SlimLine (if one is present) 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Failing serial device b. Serial cable c. Remote Supervisor Adapter II SlimLine (if one is present) d. (Trained service technician only) System board
Software problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. Symptom You suspect a software problem. Action 1. To determine whether the problem is caused by the software, make sure that: v The server has the minimum memory that is needed to use the software. For memory requirements, see the information that comes with the software. If you have just installed an adapter or memory, the server might have a memory-address conflict. v The software is designed to operate on the server. v Other software works on the server. v The software works on another server. 2. If you received any error messages when using the software, see the information that comes with the software for a description of the messages and suggested solutions to the problem. 3. Contact your place of purchase of the software.
73
Video problems
See Monitor problems on page 68.
REMIND
To acknowledge a system error but not take immediate action, press the remind button to place the server in Remind mode. When the server is in Remind mode, the system-error LED on the front of the server flashes. If a new failure occurs, the system-error LED is lit again.
74
Press the reset button to reset the server and run the power-on self-test (POST). You might have to use a pen or the end of a straightened paper clip to press the button. The server is designed so that LEDs remain lit when the server is connected to a power source but is not turned on, provided that the power supply is operating correctly. This feature helps you to isolate the problem when the operating system is shut down.
1. Remove optional devices from the server. 2. Replace the failing power supply. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to remove and install a dc power supply. See the documentation that comes with each dc power supply.
PS 1
Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to remove and install a dc power supply. See the documentation that comes with each dc power supply. 1. Make sure that the power supply is correctly seated. 2. Replace the failed power supply.
75
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. LED PS 2 Description The power supply in bay 2 has failed. Action Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply and to remove and install a dc power supply. See the documentation that comes with each dc power supply. 1. Make sure that the power supply is correctly seated. 2. Replace the failed power supply. CPU A microprocessor has failed. 1. Make sure that the failing microprocessor, which is indicated by a lit LED on the system board, is installed correctly. See the Users Guide on the IBM System x Documentation CD for information about installing a microprocessor. 2. Call for service. VRM An error occurred on the microprocessor voltage regulator module (VRM). A hardware configuration error has occurred. 1. Replace the VRM. 2. Call for service. 1. Check the microprocessors that were just installed to make sure that they are compatible with each other and with the VRM (see Installing an additional microprocessor on page 20 for compatiblity requirements). 2. (Trained service technician only) Replace an incompatible microprocessor. 3. Check the system error logs for information about the error. Replace any components that are indicated. (Use the Configuration/Setup Utility program to view the error logs.) MEM NMI S ERR SP A memory error has occurred. A machine check error has occurred. Reserved. The service processor has failed. Attention: In a dc power environment, only trained service personnel other than IBM service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 1. Remove power from the server; then, reconnect the server to power and restart the server. 2. Update the firmware on the BMC. 3. If a Remote Supervisor Adapter II SlimLine is installed, update the firmware; if the problem remains, replace the adapter. 4. DASD A hard disk drive error has occurred. Call for service Replace the failing DIMM, which is indicated by the lit LED on the system board. Check the system-error log for information about the error. (Use the Configuration/Setup Utility program to view the error logs.)
CNFG
1. Check the LEDs on the hard disk drives and replace the indicated drive. 2. Call for service.
76
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by (Trained service technician only), that step must be performed only by a trained service technician. LED RAID Description A RAID controller error has occurred. Action 1. Make sure that a RAID controller is installed. Note: The server will not start without a RAID controller installed. 2. Check the system-error log for information about the error. (Use the Configuration/Setup Utility program to view the error logs.) FAN A fan has failed, is operating too slowly, Replace the failing fan, which is indicated by a lit LED on the or has been removed. The TEMP LED fan itself. might also be lit. The system temperature has exceeded a threshold level. A failing fan can cause the TEMP LED to be lit. 1. Determine whether a fan has failed. If it has, replace it. 2. Make sure that the room temperature is not too high. See Features and specifications on page 4 for temperature information. 3. Make sure that the air vents are not blocked. 4. Call for service. 1. Check the LEDs on the system board to identify the component that is causing the error. 2. Check the system-error log for information about the error. (Use the Configuration/Setup Utility program to view the error logs.)
TEMP
BRD
PCI
An error has occurred on a PCI bus or 1. Check the LEDs on the PCI slots to identify the component on the system board. An additional LED that is causing the error. will be lit next to a failing PCI slot. 2. Check the system-error log for information about the error. (Use the Configuration/Setup Utility program to view the error logs.) 3. If you cannot isolate the failing adapter through the LEDs and the information in the system-error log, remove one adapter at a time from the failing PCI bus, and restart the server after each adapter is removed. 4. Call for service.
77
78
79
IBM Taiwan product service contact information: IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888
80
Appendix B. Notices
This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the users responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A. INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Trademarks
The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both: Active Memory Active PCI Active PCI-X AIX Alert on LAN
Copyright IBM Corp. 2007
81
Intel, Intel Xeon, Itanium, and Pentium are trademarks of Intel Corporation in the United States, other countries, or both. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Adaptec and HostRAID are trademarks of Adaptec, Inc., in the United States, other countries, or both. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Red Hat, the Red Hat Shadow Man logo, and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc., in the United States and other countries. Other company, product, or service names may be trademarks or service marks of others.
Important notes
Processor speed indicates the internal clock speed of the microprocessor; other factors also affect application performance. CD or DVD drive speed is the variable read rate. Actual speeds vary and are often less than the possible maximum. When referring to processor storage, real and virtual storage, or channel volume, KB stands for 1024 bytes, MB stands for 1 048 576 bytes, and GB stands for 1 073 741 824 bytes. When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity can vary depending on operating environments. Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives that are available from IBM. Maximum memory might require replacement of the standard memory with an optional memory module.
82
IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties. IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
Notice: This mark applies only to countries within the European Union (EU) and Norway. This appliance is labeled in accordance with European Directive 2002/96/EC concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
Appendix B. Notices
83
Remarque : Cette marque sapplique uniquement aux pays de lUnion Europenne et la Norvge. Letiquette du systme respecte la Directive europenne 2002/96/EC en matire de Dchets des Equipements Electriques et Electroniques (DEEE), qui dtermine les dispositions de retour et de recyclage applicables aux systmes utiliss travers lUnion europenne. Conformment la directive, ladite tiquette prcise que le produit sur lequel elle est appose ne doit pas tre jet mais tre rcupr en fin de vie. In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. For proper collection and treatment, contact your local IBM representative.
84
Notice: This mark applies only to countries within the European Union (EU). Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC concerning batteries and accumulators and waste batteries and accumulators. The Directive determines the framework for the return and recycling of used batteries and accumulators as applicable throughout the European Union. This label is applied to various batteries to indicate that the battery is not to be thrown away, but rather reclaimed upon end of life per this Directive. Les batteries ou emballages pour batteries sont tiquets conformment aux directives europennes 2006/66/EC, norme relative aux batteries et accumulateurs en usage et aux batteries et accumulateurs uss. Les directives dterminent la marche suivre en vigueur dans l'Union Europenne pour le retour et le recyclage des batteries et accumulateurs uss. Cette tiquette est applique sur diverses batteries pour indiquer que la batterie ne doit pas tre mise au rebut mais plutt rcupre en fin de cycle de vie selon cette norme.
In accordance with the European Directive 2006/66/EC, batteries and accumulators are labeled to indicate that they are to be collected separately and recycled at end of life. The label on the battery may also include a chemical symbol for the metal concerned in the battery (Pb for lead, Hg for mercury, and Cd for cadmium). Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and treatment of batteries and accumulators. Customer participation is important to minimize any potential effects of batteries and accumulators on the environment and human health due to the potential presence of hazardous substances. For proper collection and treatment, contact your local IBM representative. For California: Perchlorate material special handling may apply. See http://www.dtsc.ca.gov/ hazardouswaste/perchlorate/. The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. This product/part may include a lithium manganese dioxide battery which contains a perchlorate substance.
85
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
86
Telephone: 0049 (0)711 785 1176 Fax: 0049 (0)711 785 1283 E-mail: tjahn@de.ibm.com
Appendix B. Notices
87
88
Index A
ac power LED 37 acoustical noise emissions 5 adapter installing 26 Remote Supervisor Adapter II SlimLine slot locations 26 system requirements 26 ASM processor 75 assistance, getting 79 attention notices 4
E
electrical input 5 electronic emission Class A notice 85 environment 5 error messages, POST 60 error symptoms CD or DVD drive 62 general 63 hard disk drive 63 intermittent 64 keyboard, USB 65 memory 66 microprocessor 67 monitor 68 mouse, USB 65 optional devices 70 pointing device, USB 65 power 71 serial port 72 software 73 USB port 74 Ethernet activity LED 38 connector 38 link status LED 38 systems-management connector 37
29
B
baseboard management controller utility programs battery return program 84 beep codes 59 56
C
caution statements 4 CD/DVD drive activity LED 37 problems 62 CD/DVD-eject button 37 Class A electronic emission notice 85 command-line interface commands identify 57 power 57 sel 57 sysinfo 57 for remote management 56 Configuration/Setup Utility program 41 configuring RAID controller 43 SAS devices 43 configuring hardware 41 connectors front 33 rear 33 cooling 5 cover installing 33 removing 11
F
FCC Class A notice 85 filler panel 10, 19, 32 firmware code, updating 56 firmware updates 2
G
getting help 79
H
hard disk drive installing 18 problems 63 hard disk drive activity LED 36 hardware service and support 80 heat output 5 help, getting 79 hot-swap drive, installing 18 humidity 5
D
danger statements 4 device scan sequence 27 DIMMs connector locations 14 order of installation 12 display problems 68 documentation CD 2 drive, hot-swap, installing 18, 19
I
IBM Support Line 80 important notices 4 information LED 36
89
installing adapters 26 cover 33 DIMMs 12 hard disk drives 18 hot-swap drive 18, 19 microprocessor 20 RAID controller 30 Remote Supervisor Adapter II SlimLine VRM 23 intermittent problems 64
P
PCI expansion slots 5 pointing device problems 65 POST error messages 60 power problems 71 power supply specifications 5 power-control button 36 power-control-button shield 36 power-cord connector 37 power-on LED front 38 rear 36 problems CD/DVD drive 62 hard disk drive 63 intermittent 64 keyboard 65 memory 66 microprocessor 67 monitor 68 optional devices 70 power 71 serial port 72 software 73 solving 59 USB port 74 video 74 product recycling and disposal 83
29
L
LEDs Ethernet activity 38 Ethernet-link status 38 front 35 rear 37 light path diagnostics LEDs 75 panel 74 locator LED 36, 38
M
major components 6 memory installing 12 problems 66 memory module specifications 5 microprocessor heat sink 25 installing 20 problems 67 specifications 5 VRM 23 monitor problems 68 mouse problems 65
R
RAID controller installing 30 removing 30 replacing 30 recycling and disposal, product 83 Remote Supervisor Adapter II SlimLine, installing removing RAID controller 30 replacing RAID controller 30 reset button 75
29
N
notes 4 notes, important 82 notices 81 electronic emission 85 FCC, Class A 85 notices and statements 4
S
SAS hard disk drive, installing 18 integrated controller 27 SAS connector 38 scan sequence, default 27 SCSI See SAS serial connector 38 serial over LAN commands connect 57 identify 57 power 57 reboot 57
O
online documentation 2 operator information panel 35 optional device problems 70 OSA SMBridge management utility program enabling and configuring 45 installing 54
90
serial over LAN (continued) sel get 57 sol 57 sysinfo 57 serial port problems 72 ServeRAID Manager 43 ServerGuide error symptoms 61 using 41 service processor, defined 38 size 5 software problems 73 software service and support 80 solving problems 59 specifications 4 statements and notices 4 status LEDs 37 support, web site 79 system-error LED front 38 rear 36 system-locator LED 36, 38 front 38 rear 36
W
web site publication ordering 79 support 79 support line, telephone numbers weight 5 80
T
telephone numbers 80 temperature 5 thermal material heat sink 25 trademarks 81 troubleshooting chart 62 turning off the server 39 turning on the server 39
U
United States electronic emission Class A notice United States FCC Class A notice 85 Universal Serial Bus (USB) problems 74 updating the firmware code 56 USB connector front 36 rear 38 using baseboard management controller utility programs 56 ServerGuide CD 41 utility program Configuration/Setup 41 IBM ServeRAID Configuration 43 85
V
video connector front 36 rear 38 voltage regulator module installing 23
Index
91
92
Printed in USA