Dualband Combiner
Dualband Combiner
Dualband Combiner
242
Dual-Band Combiner
68 470 MHz
80 / 160 / 400 MHz
Port 1 Port 2
Input N coupler
4.3
Port 3
111.6
Output N coupler
105
40
223
Input N coupler
229.4
Port 3
Attenuation/dB
0 10 20
68 470
30 40
870 970
Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application DC transparency Port 1 Port 3 Port 2 Port 3 Port 3 Port 2 Weight Packing size Dimensions (w x h x d)
50
728954
68 470 MHz 870 970 MHz < 0.5 dB (68 470 MHz) < 0.5 dB (870 970 MHz) > 45 dB < 1.2 50 < 50 W < 50 W < 160 dBc (2 nd/3 rd order; with 2 x 20 W) 20 ... +70 C N female Indoor By-pass (max. 2500mA) short circuited stop 0.8 kg 285 x 55 x 125 mm 229.4 x 32 x 111.6 mm (without connectors)
60 70 80 90 100 0 100 200 300 400 500 600 700 800 900 1000
Frequency/MHz
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
68 470
0.7 0.8 0.9 1.0 0 100 200 300 400 500 600 700 800
870 970
900
1000
Frequency/MHz
243
Multiband Combiners
32 15
12
Dual-Band Combiner
50 470 MHz
PMR / TETRA / TETRAPOL
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or in
a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting External DC stop available as an accessory Very low insertion loss High input power
Port 3
Port 1
Port 2
78210457
78210458
78210460
Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Mounting Weight Dimensions (w x h x d)
78210457
87.5 470 MHz 806 2500 MHz
78210458
78210460
50 470 MHz 806 2500 MHz < 0.15 dB (50 470 MHz) < 0.15 dB (806 2500 MHz)
< 0.15 dB (87.5 470 MHz) < 0.15 dB (806 2500 MHz) > 50 dB (250 470 / 806 2500 MHz) > 40 dB (87.5 250 MHz) < 1.25 (87.5 470 / 806 960 / 1710 2500 MHz) 50
> 50 dB (50 470 / 806 2500 MHz) < 1.25 (50 470 / 806 960 / 1710 2500 MHz)
< 500 W < 500 W < 160 dBc (3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female, long neck Indoor or outdoor (IP 66) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop Wall mounting: With 4 screws (max. 8 mm diameter) Mast mounting: With additional clamp set 4 kg 122 x 284.7 x 52 mm (without connectors, without mounting brackets)
244
Dual-Band Combiner
50 470 MHz
PMR / TETRA / TETRAPOL
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
Attenuation/dB
0 10 20 87.5 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
0 0.1 0.2 87.5 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
Frequency/MHz
Frequency/MHz
78210458
Diagram I
Port 1 Port 3 Port 2 Port 3
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
10 20 87.5 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
Attenuation/dB
0 0.1 0.2 87.5 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
Frequency/MHz
Frequency/MHz
78210460
Diagram I
Port 1 Port 3 Port 2 Port 3
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
Attenuation/dB
0 10 20 50 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
0 0.1 0.2 50 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500
Frequency/MHz
Frequency/MHz
245
Multiband Combiners
Dual-Band Combiner
50 1000 MHz
80 / 160 / 400 / GSM 900
Port 1
Port 2
Port 3
Port 3
deep
Port 1
Port 2
Attenuation/dB
0 10 20
50 1000
30 40
1600 2000
Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR (all ports) Impedance Input power Band 1 Band 2 Temperature range Connectors Application DC transparency Port 1 Port 3 Port 2 Port 3 Port 3 Port 2 Mounting Weight Packing size Dimensions (w x h x d)
50
791145
50 1000 MHz 1600 2000 MHz < 0.3 dB (50 1000 MHz) < 0.5 dB (1600 2000 MHz) > 40 dB (50 1000 / 1600 2000 MHz) < 1.2 (50 1000 / 1600 2000 MHz) 50 < 100 W < 50 W 30 +60 C N female Indoor By-pass (max. 2500mA) Short circuited Stop With 4 screws (max.4 mm diameter) 0.7 kg 220 x 40 x 140 mm 199.5 x 23 x 110.4 mm (incl. connectors)
Attenuation/dB
60 70 80 90 100 0 200 400 600 800 1000 1200 1400 1600 1800 2000
Frequency/MHz
Diagram II
Port 1 Port 3
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 200 400 600 800 1000 1200 1400 1600 1800 2000
Port 2 Port 3
50 1000
1600 2000
Frequency/MHz
246
Dual-Band Combiner
824 880 MHz
AMPS / CDMA 850
Designed for co-siting purposes Enables feeder sharing Suitable for indoor applications Built-in DC stop between all ports
Port 3 Port 2
Attenuation/dB
Technical Data
Type No. Pass band Band 1 (AMPS / CDMA 800) Band 2 (GSM 900) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application Special features Mounting Weight Dimensions (w x h x d)
60
78210341
824 880 MHz 890 960 MHz < 0.6 dB (824 880 MHz) < 0.6 dB (890 960 MHz) > 55 dB (824 880 / 890 960 MHz) < 1.2 (824 880 / 890 960 MHz) 50 < 400 W (with max. 8 carriers) < 400 W (with max. 8 carriers) < 160 dBc (3 rd order; with 2 x 20 W) 20 ... +55 C 7-16 female Indoor Built-in DC stop between all ports With 4 screws (max. 4 mm diameter) 3.2 kg 228 x 85 x 199.3 mm (including connectors and mounting feet)
70 80 90 100 800 820 840 860 880 900 920 940 960 980 1000
Frequency/MHz
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
0 0.5 1.0 824 880 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 800 890 960
820
840
860
880
900
920
940
960
980
1000
Frequency/MHz
247
Multiband Combiners
Port 1
Dual-Band Combiner
790 862 MHz
LTE 800
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory
Port 3 Port 1
Port 2
Technical Data
Type No.
78210970
Single Unit
78210972
Single Unit
78210971
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Dimensions (w x h x d) 790 862 MHz 880 960 MHz
78210973
Double Unit
< 0.4 dB, typically 0.2 dB (790 862 MHz) < 0.4 dB, typically 0.2 dB (880 960 MHz) > 50 dB (790 862 MHz / 880 960 MHz) < 1.25 (790 862 / 880 960 MHz) 50 < 200 W / < 200 W < 160 dBc (3 rd order; with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)
3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.8 kg Single Unit: 177.4 x 209.4 x 52.4 mm / Double Unit: 177.4 x 209.4 x 108.4 mm (without connectors, without mounting brackets)
248
Dual-Band Combiner
790 862 MHz
LTE 800
790 862
880 960
DC stop
Multiband Combiners
50-Ohm load
Type No. 793301 78410367 Description DC stop 50-Ohm load
Diagram II
Port 1 Port 3 Port 2 Port 3
790 862
880 960
Please note:
The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.
249
Dual-Band Combiner
470 960 MHz
LTE 800 / CDMA 850 / GSM 900
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Extremely small dimensions and low weight Very low insertion loss High input power
Port 1
Port 3 Port 2
Technical Data
Type No.
78210660
Single Unit
78210662
Single Unit
78210664
Single Unit
78210661
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) By-pass (max. 2500 mA) By-pass (max. 2500 mA)
78210663
Double Unit 470 960 MHz 1710 2700 MHz
78210665
Double Unit
< 0.15 dB (470 960 MHz), typically 0.1 dB (470 960 MHz) < 0.2 dB (1710 2700 MHz), typically 0.1 dB (1710 2700 MHz) > 55 dB (470 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (470 960 / 1710 2700 MHz) 50 Ohm < 650 W / < 350 W < 160 dBc (3 rd order with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 1.2 kg / Double Unit: 2.4 kg Single Unit: 285 x 157 x 93 mm / Double Unit: 285 x 157 x 148 mm Single Unit: 126 x 145 x 38 mm / Double Unit: 126 x 145 x 93 mm (without connectors, without mounting brackets)
250
Dual-Band Combiner
470 960 MHz
LTE 800 / CDMA 850 / GSM 900
Diagram I
Port 1 Port 3 Port 2 Port 3
DC stop
50-Ohm load
Type No. 78210850 78410367 Description DC stop
50-Ohm load
-100 0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Frequency/MHz
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
0 -0.1 -0.2 470 960 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 1710 2700
Frequency/MHz
Side view Single Unit
251
Multiband Combiners
-50
Dual-Band Combiner
470 960 MHz
DVB-H / CDMA 850 / GSM 900
Unit 2
Port 1
Port 3
Port 2
Unit 1
Application Example
Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)
78210669
Double Unit 470 960 MHz 1710 2700 MHz < 0.1 dB (470 960 MHz) < 0.1 dB (1710 2700 MHz) > 55 dB (470 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (470 960 / 1710 2700 MHz) 50 Ohm < 650 W / < 350 W < 160 dBc (3 rd order with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Unit 1 Unit 2 By-pass (max. 2500 mA) Stop Stop By-pass (max. 2500 mA) 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set 2.4 kg 285 x 157 x 148 mm 126 x 145 x 93 mm (without connectors, without mounting brackets)
252
Dual-Band Combiner
470 960 MHz
DVB-H / CDMA 850 / GSM 900
Diagram I
Port 1 Port 3 Port 2 Port 3
DC stop
50-Ohm load
Type No. 78210850 78410367 Description DC stop
50-Ohm load
-100 0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Frequency/MHz
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
0 -0.1 -0.2 470 960 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 1710 2700
Frequency/MHz
Side view
Top view
253
Multiband Combiners
-50
Dual-Band Combiner
380 960 MHz
TETRA / LTE800 / CDMA850 / GSM900
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Extremely low insertion loss High input power
Port 1 Port 3
Port 2
380 960
1710 2700
380 960
1710 2700
Technical Data
Type No.
78210680
Single Unit
78210682
Single Unit
78210681
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) 380 960 MHz 1710 2700 MHz < 0.1 dB (380 960 MHz) < 0.1 dB (1710 2700 MHz)
78210683
Double Unit
> 55 dB (380 550 MHz) / > 65 dB (550 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (380 960 / 1710 2700 MHz) 50 < 700 W / < 700 W < 160 dBc (3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)
3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.2 kg / Double Unit: 4.3 kg Single Unit: 365 x 207 x 150 mm / Double Unit: 365 x 207 x 214 mm Single Unit: 117 x 209.5 x 48.8 mm / Double Unit: 117 x 209.5 x 99.5 mm (without connectors, without mounting brackets)
254
Dual-Band Combiner
380 960 MHz
TETRA / LTE800 / CDMA850 / GSM900
DC stop
380 960
1710 2700
50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
0 0.1 0.2 380 960 0.3 0.4 0.5 0.6 1710 2700
0.7 0.8 0.9 1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000
Frequency/MHz
Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.
255
Multiband Combiners
Dual-Band Combiner
790 1880 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS
Port 3 Port 1
Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol an-
tennas as a double unit Built-in lightning protection External DC Stop available as an accessory
Technical Data
Type No.
78210278
Single Unit
78210305
Single Unit
78210279
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) 790 1880 MHz 1920 2170 MHz
78210306
Double Unit
< 0.1 dB, typically 0.05 dB (790 960 MHz) / < 0.4 dB, typically 0.2 dB (1710 1880 MHz) < 0.4 dB, typically 0.2 dB (1920 2170 MHz) > 55 dB (790 960 MHz) / > 50 dB (1710 1880 MHz) / > 50 dB (1920 2170 MHz) < 1.2 (790 960 MHz) / < 1.25 (1710 1880 MHz) / < 1.2 (1920 2170 MHz) 50 < 500 W / < 500 W < 160 dBc (2 nd/3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)
3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 3.4 kg / Double Unit: 6.6 kg Single Unit: 207 x 437 x 154 mm / Double Unit: 207 x 437 x 214 mm Single Unit: 122 x 269.9 x 43 mm / Double Unit:122 x 269.9 x 98.5 mm (without connectors, without mounting brackets)
256
Dual-Band Combiner
790 1880 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800
790 1880
1920 2170
DC stop
Multiband Combiners
50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load
Diagram II
Port 1 Port 3 Port 2 Port 3
790 1880
1920 2170
Please note: The mounting plates can be removed by loosening the screws to (M5 x 10) and replaced with other means of mounting, always provided that the max. drilled depth of 8.5 mm is respected with the choice of replacement screws.
Dual-Band Combiner
1710 1880 MHz
GSM 1800
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS
Port 3 Port 1
or in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC Stop available as an accessory
Port 2
Technical Data
Type No.
78210620
Single Unit
78210622
Single Unit
78210624
Single Unit
78210621
Double Unit Pass band Band 1 (GSM 1800) Band 2 (UMTS) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)
78210623
Double Unit 1710 1880 MHz 1920 2170 MHz < 0.3 dB (1710 1880 MHz) < 0.3 dB (1920 2170 MHz) > 50 dB (1710 1880 / 1920 2170 MHz) < 1.25 (1710 1880 / 1920 2170 MHz) 50 < 300 W / < 300 W < 160 dBc (3 rd order; with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66)
78210625
Double Unit
Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.7 kg Single Unit: 392 x 272 x 139 mm / Double Unit: 392 x 272 x 189 mm Single Unit: 199 x 199 x 48 mm / Double Unit: 199 x 199 x 104 mm (without connectors, without mounting brackets)
258
Dual-Band Combiner
1710 1880 MHz
GSM 1800
Clamp Set
Attenuation/dB
DC stop
50-Ohm load
1500
1600
1700
1800
1900
2000
2100
2200
2300 2400
Frequency/MHz
Diagram II
Port 1 Port 3 Side view Single Unit Port 2 Port 3
1710 1880
1920 2170
Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.
259
Multiband Combiners
Dual-Band Combiner
1710 1880 MHz
GSM 1800
Unit 2
Port 3
Port 2
Unit 1
Application Example
1710 - 1880
1920 - 2170
Unit 1
Unit 2
Technical Data
Type No. Pass band Band 1 (GSM 1800) Band 2 (UMTS) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)
78210626
Double Unit 1710 1880 MHz 1920 2170 MHz < 0.3 dB (1710 1880 MHz) < 0.3 dB (1920 2170 MHz) > 50 dB (1710 1880 / 1920 2170 MHz) < 1.25 (1710 1880 / 1920 2170 MHz) 50 Ohm < 300 W / < 300 W < 160 dBc (3rd order with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Unit 1 Unit 2 By-pass (max. 2500 mA) Stop Stop By-pass (max. 2500 mA) 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set 5.7 kg 392 x 272 x 189 mm 199 x 199 x 104 mm (without connectors, without mounting brackets)
260
Dual-Band Combiner
1710 1880 MHz
GSM 1800
Clamp Set
Attenuation/dB
0 -10 -20 1710 1880 -30 -40 -50 -60 -70 -80 -90 1920 2170
DC stop
50-Ohm load
-100 1400
1500
1600
1700
1800
1900
2000
2100
2200
2300 2400
Frequency/MHz
DC
AISG
Unit 2
Diagram II
Port 1 Port 3 Port 2 Port 3
Front view
Attenuation/dB
0 -0.1 -0.2 1710 1880 -0.3 -0.4 -0.5 -0.6 -0.7 1920 2170
DC
AISG
Unit 1
Unit 1
Top view
1500
1600
1700
1800
1900
2000
2100
2200
2300 2400
Frequency/MHz
Bottom view
261
Multiband Combiners
Dual-Band Combiner
1850 1910 / 1930 1990 MHz
PCS
Designed for co-siting purposes Enables feeder sharing Suitable for indoor or outdoor applications With fault detection and integrated switch
for multiple DC power supply
AWS
COM ANT
PCS
78210469
Attenuation/dB
0 -10 1850 1910 -20 -30 -40 -50 -60 -70 -80 -90 1710 1755 1930 1990 2110 2155
Technical Data
Type No. Pass band Band 1 (PCS) Band 2 (AWS) Insertion loss Port PCS Port ANT Port AWS Port ANT Isolation Port PCS Port AWS VSWR Impedance Input power Port PCS Port AWS Intermodulation products Power supply voltage operational survival Polarity protection Max. Current Power supply current at PCS port operating with dummy load Lightning protection Temperature range Connectors Application Weight Dimensions (w x h x d)
78210469
Single unit
78210808
Double unit
1850 1910 (Rx) / 1930 1990 (Tx) MHz 1710 1755 (Rx) / 2110 2155 (Tx) MHz < 0.3 dB (1850 1910 / 1930 1990 MHz) < 0.2 dB (1710 1755 / 2110 2155 MHz) > 50 dB (1850 1910 / 1930 1990 MHz) > 50 dB (1710 1755 / 2110 2155 MHz) < 1.25 (1850 1910 / 1930 1990 MHz) < 1.25 (1710 1755 / 2110 2155 MHz) 50 < 250 W (1850 1910 / 1930 1990 MHz) < 250 W (1710 1755 / 2110 2155 MHz) < 160 dBc (3 rd order; with 2 x 20 W) +10 +15 V DC (Port PCS) +10 +30 V DC (Port AWS) +10 +35 V DC 48 V DC (Port PCS, Port AWS) 1.5 A (Port ANT) 100 mA 20 mA (+10 ... +15 V DC) 8/20 s, 20 kA; 10/350 s, 3 kA (Port ANT) 40 ... +65 C 7-16 female (long neck) Indoor or outdoor (IP 66) 2.5 kg 5 kg 122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm (without connectors, without mounting brackets)
-100 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200
Frequency/MHz
Diagram II
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT
0 -0.1 -0.2 1710 1755 -0.3 1850 1910 -0.4 1930 1990 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200 2110 2155
Attenuation/dB
Frequency/MHz
262
Dual-Band Combiner
1850 1910 / 1930 1990 MHz
PCS
Designed for co-siting purposes Enables feeder sharing Suitable for indoor or outdoor applications DC by-pass between all ports External DC stop available as an accessory
COM ANT
AWS
PCS
78210809
Attenuation/dB
0 -10 1850 1910 -20 -30 -40 -50 -60 -70 1710 1755 1930 1990 2110 2155
Technical Data
Type No. Pass band Band 1 (PCS) Band 2 (AWS) Insertion loss Port PCS Port ANT Port AWS Port ANT Isolation Port PCS Port AWS VSWR Impedance Input power Port PCS Port AWS Intermodulation products Lightning protection Temperature range Connectors Application DC/AISG transparency Weight Dimensions (w x h x d)
78210809
Single unit
78210810
Double unit
-80 -90 -100 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200
1850 1910 (Rx) / 1930 1990 (Tx) MHz 1710 1755 (Rx) / 2110 2155 (Tx) MHz < 0.3 dB (1850 1910 / 1930 1990 MHz) < 0.2 dB (1710 1755 / 2110 2155 MHz) > 50 dB (1850 1910 / 1930 1990 MHz) > 50 dB (1710 1755 / 2110 2155 MHz) < 1.25 (1850 1910 / 1930 1990 MHz) < 1.25 (1710 1755 / 2110 2155 MHz) 50 < 250 W (1850 1910 / 1930 1990 MHz) < 250 W (1710 1755 / 2110 2155 MHz) < 160 dBc (3 rd order; with 2 x 20 W) 3 kA, 10/350 s pulse 40 ... +65 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass between all ports (max. 2500 mA) 2.5 kg 5 kg 122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm (without connectors, without mounting brackets)
Frequency/MHz
Diagram II
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT
0 -0.1 -0.2 1710 1755 -0.3 1850 1910 -0.4 1930 1990 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200 2110 2155
Attenuation/dB
Frequency/MHz
263
Multiband Combiners
Dual-Band Combiner
1710 2180 MHz
GSM1800 / PCS1900 / AWS / UMTS2100
Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
Port 1
Port 3
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Very low insertion loss
Port 2
1710 2180
2400 2700
1710 2180
2400 2700
Technical Data
Type No.
78210800
Single Unit
78211092
Single Unit
78211094
Single Unit
78211091
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) By-pass (max. 2500 mA) By-pass (max. 2500 mA)
78211093
Double Unit 1710 2180 MHz 2400 2700 MHz < 0.15 dB < 0.15 dB > 60 dB < 1.25 (1710 2180 / 2400 2700 MHz) 50 < 300 W / < 300 W < 160 dBc (3 rd order with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66)
78211095
Double Unit
Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.7 kg Single Unit: 392 x 272 x 139 mm / Double Unit: 392 x 272 x 189 mm Single Unit: 199 x 199 x 44 mm / Double Unit: 199 x 199 x 95 mm (without connectors, without mounting brackets)
264
Dual-Band Combiner
1710 2180 MHz
GSM1800 / PCS1900 / AWS / UMTS2100
Clamp Set
Attenuation/dB
DC stop
50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load
Frequency/MHz
Diagram II
Port 1 Port 3 Port 2 Port 3
Attenuation/dB
0.6 0.7 0.8 0.9 1.0 1500 1650 1800 1950 2100
Frequency/MHz
Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.
265