Multiband Combiner Frequency combinations

Dual-Band Combiner, Triple-Band Combiner, Quad-Band Combiner

242

Dual-Band Combiner
68 470 MHz
80 / 160 / 400 MHz

870 970 MHz


GSM 900

Designed for inhouse multiband distribution


network Enables feeder sharing DC by-pass between port 1 and port 3 Built-in DC stop between port 2 and port 3
18.7

Port 1 Port 2

Input N coupler

4.3

Port 3

111.6

Output N coupler

105

40

223

Input N coupler

229.4

Port 3

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 10 20

68 470
30 40

870 970

Port 1 68 470 MHz

Port 2 870 970 MHz

Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application DC transparency Port 1 Port 3 Port 2 Port 3 Port 3 Port 2 Weight Packing size Dimensions (w x h x d)

50

728954
68 470 MHz 870 970 MHz < 0.5 dB (68 470 MHz) < 0.5 dB (870 970 MHz) > 45 dB < 1.2 50 < 50 W < 50 W < 160 dBc (2 nd/3 rd order; with 2 x 20 W) 20 ... +70 C N female Indoor By-pass (max. 2500mA) short circuited stop 0.8 kg 285 x 55 x 125 mm 229.4 x 32 x 111.6 mm (without connectors)

60 70 80 90 100 0 100 200 300 400 500 600 700 800 900 1000

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 0.1 0.2 0.3 0.4 0.5 0.6

68 470
0.7 0.8 0.9 1.0 0 100 200 300 400 500 600 700 800

870 970

900

1000

Frequency/MHz

243

Multiband Combiners

32 15

12

Dual-Band Combiner
50 470 MHz
PMR / TETRA / TETRAPOL

806 2500 MHz


CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 / WLAN

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or in
a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting External DC stop available as an accessory Very low insertion loss High input power

Port 3

Port 1

Port 2

78210457

78210458

78210460

Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Mounting Weight Dimensions (w x h x d)

78210457
87.5 470 MHz 806 2500 MHz

78210458

78210460
50 470 MHz 806 2500 MHz < 0.15 dB (50 470 MHz) < 0.15 dB (806 2500 MHz)

< 0.15 dB (87.5 470 MHz) < 0.15 dB (806 2500 MHz) > 50 dB (250 470 / 806 2500 MHz) > 40 dB (87.5 250 MHz) < 1.25 (87.5 470 / 806 960 / 1710 2500 MHz) 50

> 50 dB (50 470 / 806 2500 MHz) < 1.25 (50 470 / 806 960 / 1710 2500 MHz)

< 500 W < 500 W < 160 dBc (3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female, long neck Indoor or outdoor (IP 66) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop Wall mounting: With 4 screws (max. 8 mm diameter) Mast mounting: With additional clamp set 4 kg 122 x 284.7 x 52 mm (without connectors, without mounting brackets)

244

Dual-Band Combiner
50 470 MHz
PMR / TETRA / TETRAPOL

806 2500 MHz


CDMA 850 / GSM 900 / GSM 1800 / UMTS 2100 / WLAN

Typical Attenuation Curves


78210457
Diagram I
Port 1 Port 3 Port 2 Port 3

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

Attenuation/dB

0 10 20 87.5 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

0 0.1 0.2 87.5 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

Frequency/MHz

Frequency/MHz

78210458
Diagram I
Port 1 Port 3 Port 2 Port 3

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

10 20 87.5 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

Attenuation/dB

0 0.1 0.2 87.5 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

Frequency/MHz

Frequency/MHz

78210460
Diagram I
Port 1 Port 3 Port 2 Port 3

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

Attenuation/dB

0 10 20 50 470 30 40 50 60 70 80 90 100 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

0 0.1 0.2 50 470 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 806 2500

Frequency/MHz

Frequency/MHz

245

Multiband Combiners

Dual-Band Combiner
50 1000 MHz
80 / 160 / 400 / GSM 900

1600 2000 MHz


GSM 1800

Designed for inhouse multiband distribution


network Enables feeder sharing DC by-pass between port 1 and port 3 Built-in DC stop between port 2 and port 3

Port 1

Port 2

Port 3

Port 3

deep

Port 1

Port 2

50 1000 MHz 1600 2000 MHz

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 10 20

50 1000
30 40

1600 2000

Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR (all ports) Impedance Input power Band 1 Band 2 Temperature range Connectors Application DC transparency Port 1 Port 3 Port 2 Port 3 Port 3 Port 2 Mounting Weight Packing size Dimensions (w x h x d)

50

791145
50 1000 MHz 1600 2000 MHz < 0.3 dB (50 1000 MHz) < 0.5 dB (1600 2000 MHz) > 40 dB (50 1000 / 1600 2000 MHz) < 1.2 (50 1000 / 1600 2000 MHz) 50 < 100 W < 50 W 30 +60 C N female Indoor By-pass (max. 2500mA) Short circuited Stop With 4 screws (max.4 mm diameter) 0.7 kg 220 x 40 x 140 mm 199.5 x 23 x 110.4 mm (incl. connectors)
Attenuation/dB

60 70 80 90 100 0 200 400 600 800 1000 1200 1400 1600 1800 2000

Frequency/MHz

Diagram II
Port 1 Port 3
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 200 400 600 800 1000 1200 1400 1600 1800 2000

Port 2 Port 3

50 1000

1600 2000

Frequency/MHz

246

Dual-Band Combiner
824 880 MHz
AMPS / CDMA 850

890 960 MHz


GSM 900

Designed for co-siting purposes Enables feeder sharing Suitable for indoor applications Built-in DC stop between all ports

Port 3 Port 2

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 10 20 824 880 30 40 50 890 960

Technical Data
Type No. Pass band Band 1 (AMPS / CDMA 800) Band 2 (GSM 900) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 Band 2 Intermodulation products Temperature range Connectors Application Special features Mounting Weight Dimensions (w x h x d)

60

78210341
824 880 MHz 890 960 MHz < 0.6 dB (824 880 MHz) < 0.6 dB (890 960 MHz) > 55 dB (824 880 / 890 960 MHz) < 1.2 (824 880 / 890 960 MHz) 50 < 400 W (with max. 8 carriers) < 400 W (with max. 8 carriers) < 160 dBc (3 rd order; with 2 x 20 W) 20 ... +55 C 7-16 female Indoor Built-in DC stop between all ports With 4 screws (max. 4 mm diameter) 3.2 kg 228 x 85 x 199.3 mm (including connectors and mounting feet)

70 80 90 100 800 820 840 860 880 900 920 940 960 980 1000

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 0.5 1.0 824 880 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 800 890 960

820

840

860

880

900

920

940

960

980

1000

Frequency/MHz

247

Multiband Combiners

Port 1

Dual-Band Combiner
790 862 MHz
LTE 800

880 960 MHz


GSM 900

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or

in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory

Port 3 Port 1

Port 2

78210970, 78210972 Single Unit

78210971, 78210973 Double Unit

Technical Data
Type No.

78210970
Single Unit

78210972
Single Unit

78210971
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Dimensions (w x h x d) 790 862 MHz 880 960 MHz

78210973
Double Unit

< 0.4 dB, typically 0.2 dB (790 862 MHz) < 0.4 dB, typically 0.2 dB (880 960 MHz) > 50 dB (790 862 MHz / 880 960 MHz) < 1.25 (790 862 / 880 960 MHz) 50 < 200 W / < 200 W < 160 dBc (3 rd order; with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)

3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.8 kg Single Unit: 177.4 x 209.4 x 52.4 mm / Double Unit: 177.4 x 209.4 x 108.4 mm (without connectors, without mounting brackets)

248

Dual-Band Combiner
790 862 MHz
LTE 800

880 960 MHz


GSM 900

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm

Typical Attenuation Curves Clamp Set


Diagram I
Port 1 Port 3 Port 2 Port 3

790 862

880 960

DC stop
Multiband Combiners

50-Ohm load
Type No. 793301 78410367 Description DC stop 50-Ohm load

Diagram II
Port 1 Port 3 Port 2 Port 3

790 862

880 960

Side view Single Unit

Side view Double Unit

Top view Single Unit, Double Unit

Please note:

Bottom view Single Unit, Double Unit

The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

249

Dual-Band Combiner
470 960 MHz
LTE 800 / CDMA 850 / GSM 900

1710 2700 MHz


GSM 1800 / UMTS 2100 / WiMAX / LTE 2600

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Extremely small dimensions and low weight Very low insertion loss High input power

Port 1

Port 3 Port 2

78210660, 78210662, 78210664 Single Unit

78210661, 78210663, 78210665 Double Unit

Technical Data
Type No.

78210660
Single Unit

78210662
Single Unit

78210664
Single Unit

78210661
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) By-pass (max. 2500 mA) By-pass (max. 2500 mA)

78210663
Double Unit 470 960 MHz 1710 2700 MHz

78210665
Double Unit

< 0.15 dB (470 960 MHz), typically 0.1 dB (470 960 MHz) < 0.2 dB (1710 2700 MHz), typically 0.1 dB (1710 2700 MHz) > 55 dB (470 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (470 960 / 1710 2700 MHz) 50 Ohm < 650 W / < 350 W < 160 dBc (3 rd order with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 1.2 kg / Double Unit: 2.4 kg Single Unit: 285 x 157 x 93 mm / Double Unit: 285 x 157 x 148 mm Single Unit: 126 x 145 x 38 mm / Double Unit: 126 x 145 x 93 mm (without connectors, without mounting brackets)

250

Dual-Band Combiner
470 960 MHz
LTE 800 / CDMA 850 / GSM 900

1710 2700 MHz


GSM 1800 / UMTS 2100 / WiMAX / LTE 2600

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm
-60

Typical Attenuation Curves Clamp Set


Attenuation/dB
0 -10 -20 470 960 -30 -40 1710 2700

Diagram I
Port 1 Port 3 Port 2 Port 3

DC stop

50-Ohm load
Type No. 78210850 78410367 Description DC stop

-70 -80 -90

50-Ohm load
-100 0 300 600 900 1200 1500 1800 2100 2400 2700 3000

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 -0.1 -0.2 470 960 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 1710 2700

Frequency/MHz
Side view Single Unit

Side view Double Unit

Top view Single Unit, Double Unit

251

Multiband Combiners

-50

Dual-Band Combiner
470 960 MHz
DVB-H / CDMA 850 / GSM 900

1710 2700 MHz


GSM 1800 / UMTS 2100 / WiMAX / LTE 2600

Designed to support separate DC/AISG supply for


a low-band and high-band DTMA via 2 feeder cables (see application) Enables feeder sharing Can be used as a combiner near the BTS or in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Double unit for XPol antennas Built-in lightning protection Extremely small dimensions and low weight Very low insertion loss High input power

Unit 2

Port 1

Port 3

Port 2

Unit 1

Application Example

Technical Data
Type No. Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)

78210669
Double Unit 470 960 MHz 1710 2700 MHz < 0.1 dB (470 960 MHz) < 0.1 dB (1710 2700 MHz) > 55 dB (470 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (470 960 / 1710 2700 MHz) 50 Ohm < 650 W / < 350 W < 160 dBc (3 rd order with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Unit 1 Unit 2 By-pass (max. 2500 mA) Stop Stop By-pass (max. 2500 mA) 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set 2.4 kg 285 x 157 x 148 mm 126 x 145 x 93 mm (without connectors, without mounting brackets)

252

Dual-Band Combiner
470 960 MHz
DVB-H / CDMA 850 / GSM 900

1710 2700 MHz


GSM 1800 / UMTS 2100 / WiMAX / LTE 2600

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm
-60

Typical Attenuation Curves Clamp Set


Attenuation/dB
0 -10 -20 470 960 -30 -40 1710 2700

Diagram I
Port 1 Port 3 Port 2 Port 3

DC stop

50-Ohm load
Type No. 78210850 78410367 Description DC stop

-70 -80 -90

50-Ohm load
-100 0 300 600 900 1200 1500 1800 2100 2400 2700 3000

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 -0.1 -0.2 470 960 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 1710 2700

Frequency/MHz

Side view

Top view

253

Multiband Combiners

-50

Dual-Band Combiner
380 960 MHz
TETRA / LTE800 / CDMA850 / GSM900

1710 2700 MHz


GSM1800 / UMTS2100 / WiMAX / LTE2600

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or
in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Extremely low insertion loss High input power
Port 1 Port 3

Port 2

78210680, 78210682 Single Unit

78210681, 78210683 Double Unit

380 960

1710 2700

380 960

1710 2700

Technical Data
Type No.

78210680
Single Unit

78210682
Single Unit

78210681
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) 380 960 MHz 1710 2700 MHz < 0.1 dB (380 960 MHz) < 0.1 dB (1710 2700 MHz)

78210683
Double Unit

> 55 dB (380 550 MHz) / > 65 dB (550 960 MHz) / > 65 dB (1710 2700 MHz) < 1.2 (380 960 / 1710 2700 MHz) 50 < 700 W / < 700 W < 160 dBc (3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)

3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.2 kg / Double Unit: 4.3 kg Single Unit: 365 x 207 x 150 mm / Double Unit: 365 x 207 x 214 mm Single Unit: 117 x 209.5 x 48.8 mm / Double Unit: 117 x 209.5 x 99.5 mm (without connectors, without mounting brackets)

254

Dual-Band Combiner
380 960 MHz
TETRA / LTE800 / CDMA850 / GSM900

1710 2700 MHz


GSM1800 / UMTS2100 / WiMAX / LTE2600

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm

Typical Attenuation Curves Clamp Set


Diagram I
Port 1 Port 3 Port 2 Port 3

DC stop

380 960

1710 2700

50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 0.1 0.2 380 960 0.3 0.4 0.5 0.6 1710 2700

Side view Single Unit

0.7 0.8 0.9 1.0 0 300 600 900 1200 1500 1800 2100 2400 2700 3000

Side view Double Unit

Frequency/MHz

Top view Single Unit, Double Unit

Bottom view Single Unit, Double Unit

Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

255

Multiband Combiners

Dual-Band Combiner
790 1880 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800

1920 2170 MHz


UMTS 2100

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS

Port 3 Port 1

or in a reciprocal function near the antenna


Port 2

Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol an-

tennas as a double unit Built-in lightning protection External DC Stop available as an accessory

78210278, 78210305 Single Unit

78210279, 78210306 Double Unit

Technical Data
Type No.

78210278
Single Unit

78210305
Single Unit

78210279
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) 790 1880 MHz 1920 2170 MHz

78210306
Double Unit

< 0.1 dB, typically 0.05 dB (790 960 MHz) / < 0.4 dB, typically 0.2 dB (1710 1880 MHz) < 0.4 dB, typically 0.2 dB (1920 2170 MHz) > 55 dB (790 960 MHz) / > 50 dB (1710 1880 MHz) / > 50 dB (1920 2170 MHz) < 1.2 (790 960 MHz) / < 1.25 (1710 1880 MHz) / < 1.2 (1920 2170 MHz) 50 < 500 W / < 500 W < 160 dBc (2 nd/3 rd order; with 2 x 20 W) 55 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop By-pass (max. 2500 mA)

3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 3.4 kg / Double Unit: 6.6 kg Single Unit: 207 x 437 x 154 mm / Double Unit: 207 x 437 x 214 mm Single Unit: 122 x 269.9 x 43 mm / Double Unit:122 x 269.9 x 98.5 mm (without connectors, without mounting brackets)

256

Dual-Band Combiner
790 1880 MHz
LTE 800 / CDMA 850 / GSM 900 / GSM 1800

1920 2170 MHz


UMTS

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm

Typical Attenuation Curves Clamp Set


Diagram I
Port 1 Port 3 Port 2 Port 3

790 1880

1920 2170

DC stop
Multiband Combiners

50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load

Diagram II
Port 1 Port 3 Port 2 Port 3

790 1880

1920 2170

Side view, Single Unit

Side view, Double Unit

Top view, Single Unit, Double Unit

Please note: The mounting plates can be removed by loosening the screws to (M5 x 10) and replaced with other means of mounting, always provided that the max. drilled depth of 8.5 mm is respected with the choice of replacement screws.

4 screws M5 x 10 4 spring washers 5.5 DIN 6095

Bottom view, Single Unit, Double Unit 257

Dual-Band Combiner
1710 1880 MHz
GSM 1800

1920 2170 MHz


UMTS 2100

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS

Port 3 Port 1

or in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC Stop available as an accessory

Port 2

78210620, 78210622, 78210624 Single Unit

78210621, 78210623, 78210625 Double Unit

Technical Data
Type No.

78210620
Single Unit

78210622
Single Unit

78210624
Single Unit

78210621
Double Unit Pass band Band 1 (GSM 1800) Band 2 (UMTS) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)

78210623
Double Unit 1710 1880 MHz 1920 2170 MHz < 0.3 dB (1710 1880 MHz) < 0.3 dB (1920 2170 MHz) > 50 dB (1710 1880 / 1920 2170 MHz) < 1.25 (1710 1880 / 1920 2170 MHz) 50 < 300 W / < 300 W < 160 dBc (3 rd order; with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66)

78210625
Double Unit

By-pass (max. 2500 mA) By-pass (max. 2500 mA)

Stop By-pass (max. 2500 mA) 3 kA, 10/350 s pulse

By-pass (max. 2500 mA) Stop

Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.7 kg Single Unit: 392 x 272 x 139 mm / Double Unit: 392 x 272 x 189 mm Single Unit: 199 x 199 x 48 mm / Double Unit: 199 x 199 x 104 mm (without connectors, without mounting brackets)

258

Dual-Band Combiner
1710 1880 MHz
GSM 1800

1920 2170 MHz


UMTS 2100

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Type No. 793301 78410367 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm Description DC stop 50-Ohm load

Clamp Set

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 -10 -20 1710 1880 -30 -40 -50 1920 2170

DC stop

50-Ohm load

-60 -70 -80 -90 -100 1400

1500

1600

1700

1800

1900

2000

2100

2200

2300 2400

Frequency/MHz

Diagram II
Port 1 Port 3 Side view Single Unit Port 2 Port 3

1710 1880

1920 2170

Side view Double Unit

Top view Single Unit, Double Unit

Bottom view Single Unit, Double Unit

Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

259

Multiband Combiners

Dual-Band Combiner
1710 1880 MHz
GSM 1800

1920 2170 MHz


UMTS 2100

Designed to support separate DC/AISG supply


for a low-band and high-band DTMA via 2 feeder cables (see application) Enables feeder sharing Can be used as a combiner near the BTS or in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Double unit for XPol antennas Built-in lightning protection
Port 1

Unit 2

Port 3

Port 2

Unit 1

Application Example

1710 - 1880 1920 - 2170

1710 - 1880

1920 - 2170

Unit 1

Unit 2

Technical Data
Type No. Pass band Band 1 (GSM 1800) Band 2 (UMTS) Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d)

78210626
Double Unit 1710 1880 MHz 1920 2170 MHz < 0.3 dB (1710 1880 MHz) < 0.3 dB (1920 2170 MHz) > 50 dB (1710 1880 / 1920 2170 MHz) < 1.25 (1710 1880 / 1920 2170 MHz) 50 Ohm < 300 W / < 300 W < 160 dBc (3rd order with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66) Unit 1 Unit 2 By-pass (max. 2500 mA) Stop Stop By-pass (max. 2500 mA) 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set 5.7 kg 392 x 272 x 189 mm 199 x 199 x 104 mm (without connectors, without mounting brackets)

260

Dual-Band Combiner
1710 1880 MHz
GSM 1800

1920 2170 MHz


UMTS 2100

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Type No. 793301 78410367 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm Description DC stop 50-Ohm load

Clamp Set

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 -10 -20 1710 1880 -30 -40 -50 -60 -70 -80 -90 1920 2170

DC stop

50-Ohm load

-100 1400

1500

1600

1700

1800

1900

2000

2100

2200

2300 2400

Frequency/MHz
DC
AISG

Unit 2

Diagram II
Port 1 Port 3 Port 2 Port 3

Front view

Attenuation/dB

0 -0.1 -0.2 1710 1880 -0.3 -0.4 -0.5 -0.6 -0.7 1920 2170

DC
AISG

Unit 1

Unit 2 Side view

Unit 1

-0.8 -0.9 -1.0 1400

Top view

1500

1600

1700

1800

1900

2000

2100

2200

2300 2400

Frequency/MHz

Bottom view

261

Multiband Combiners

Dual-Band Combiner
1850 1910 / 1930 1990 MHz
PCS

1710 1755 / 2110 2155 MHz


AWS

Designed for co-siting purposes Enables feeder sharing Suitable for indoor or outdoor applications With fault detection and integrated switch
for multiple DC power supply
AWS

COM ANT

PCS

78210469

Typical Attenuation Curves


Diagram I
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT

Attenuation/dB

0 -10 1850 1910 -20 -30 -40 -50 -60 -70 -80 -90 1710 1755 1930 1990 2110 2155

Technical Data
Type No. Pass band Band 1 (PCS) Band 2 (AWS) Insertion loss Port PCS Port ANT Port AWS Port ANT Isolation Port PCS Port AWS VSWR Impedance Input power Port PCS Port AWS Intermodulation products Power supply voltage operational survival Polarity protection Max. Current Power supply current at PCS port operating with dummy load Lightning protection Temperature range Connectors Application Weight Dimensions (w x h x d)

78210469
Single unit

78210808
Double unit

1850 1910 (Rx) / 1930 1990 (Tx) MHz 1710 1755 (Rx) / 2110 2155 (Tx) MHz < 0.3 dB (1850 1910 / 1930 1990 MHz) < 0.2 dB (1710 1755 / 2110 2155 MHz) > 50 dB (1850 1910 / 1930 1990 MHz) > 50 dB (1710 1755 / 2110 2155 MHz) < 1.25 (1850 1910 / 1930 1990 MHz) < 1.25 (1710 1755 / 2110 2155 MHz) 50 < 250 W (1850 1910 / 1930 1990 MHz) < 250 W (1710 1755 / 2110 2155 MHz) < 160 dBc (3 rd order; with 2 x 20 W) +10 +15 V DC (Port PCS) +10 +30 V DC (Port AWS) +10 +35 V DC 48 V DC (Port PCS, Port AWS) 1.5 A (Port ANT) 100 mA 20 mA (+10 ... +15 V DC) 8/20 s, 20 kA; 10/350 s, 3 kA (Port ANT) 40 ... +65 C 7-16 female (long neck) Indoor or outdoor (IP 66) 2.5 kg 5 kg 122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm (without connectors, without mounting brackets)

-100 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

Frequency/MHz

Diagram II
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT
0 -0.1 -0.2 1710 1755 -0.3 1850 1910 -0.4 1930 1990 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200 2110 2155

Attenuation/dB

Frequency/MHz

262

Dual-Band Combiner
1850 1910 / 1930 1990 MHz
PCS

1710 1755 / 2110 2155 MHz


AWS

Designed for co-siting purposes Enables feeder sharing Suitable for indoor or outdoor applications DC by-pass between all ports External DC stop available as an accessory

COM ANT

AWS

PCS

78210809

Typical Attenuation Curves


Diagram I
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT

Attenuation/dB

0 -10 1850 1910 -20 -30 -40 -50 -60 -70 1710 1755 1930 1990 2110 2155

Technical Data
Type No. Pass band Band 1 (PCS) Band 2 (AWS) Insertion loss Port PCS Port ANT Port AWS Port ANT Isolation Port PCS Port AWS VSWR Impedance Input power Port PCS Port AWS Intermodulation products Lightning protection Temperature range Connectors Application DC/AISG transparency Weight Dimensions (w x h x d)

78210809
Single unit

78210810
Double unit

-80 -90 -100 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

1850 1910 (Rx) / 1930 1990 (Tx) MHz 1710 1755 (Rx) / 2110 2155 (Tx) MHz < 0.3 dB (1850 1910 / 1930 1990 MHz) < 0.2 dB (1710 1755 / 2110 2155 MHz) > 50 dB (1850 1910 / 1930 1990 MHz) > 50 dB (1710 1755 / 2110 2155 MHz) < 1.25 (1850 1910 / 1930 1990 MHz) < 1.25 (1710 1755 / 2110 2155 MHz) 50 < 250 W (1850 1910 / 1930 1990 MHz) < 250 W (1710 1755 / 2110 2155 MHz) < 160 dBc (3 rd order; with 2 x 20 W) 3 kA, 10/350 s pulse 40 ... +65 C 7-16 female (long neck) Indoor or outdoor (IP 66) By-pass between all ports (max. 2500 mA) 2.5 kg 5 kg 122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm (without connectors, without mounting brackets)

Frequency/MHz

Diagram II
Port Port AWS ANT Port Port PCS ANT Port Port AWS ANT
0 -0.1 -0.2 1710 1755 -0.3 1850 1910 -0.4 1930 1990 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200 2110 2155

Attenuation/dB

Frequency/MHz

263

Multiband Combiners

Dual-Band Combiner
1710 2180 MHz
GSM1800 / PCS1900 / AWS / UMTS2100

2400 2700 MHz


WLAN / WiMAX / BRS/ LTE2600

Designed for co-siting purposes Enables feeder sharing Can be used as a combiner near the BTS or

Port 1

Port 3

in a reciprocal function near the antenna Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection External DC stop available as an accessory Very low insertion loss

Port 2

78210800, 78211092, 78211094 Single Unit

78211091, 78211093, 78211095 Double Unit

1710 2180

2400 2700

1710 2180

2400 2700

1710 2180 2400 2700

Technical Data
Type No.

78210800
Single Unit

78211092
Single Unit

78211094
Single Unit

78211091
Double Unit Pass band Band 1 Band 2 Insertion loss Port 1 Port 3 Port 2 Port 3 Isolation Port 1 Port 2 VSWR Impedance Input power Band 1 / Band 2 Intermodulation products Temperature range Connectors Application DC/AISG transparency Port 1 Port 3 Port 2 Port 3 Lightning protection Mounting Weight Packing size Dimensions (w x h x d) By-pass (max. 2500 mA) By-pass (max. 2500 mA)

78211093
Double Unit 1710 2180 MHz 2400 2700 MHz < 0.15 dB < 0.15 dB > 60 dB < 1.25 (1710 2180 / 2400 2700 MHz) 50 < 300 W / < 300 W < 160 dBc (3 rd order with 2 x 20 W) 40 ... +60 C 7-16 female (long neck) Indoor or outdoor (IP 66)

78211095
Double Unit

Stop By-pass (max. 2500 mA) By-pass (max. 2500 mA) Stop 3 kA, 10/350 s pulse Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set Single Unit: 2.9 kg / Double Unit: 5.7 kg Single Unit: 392 x 272 x 139 mm / Double Unit: 392 x 272 x 189 mm Single Unit: 199 x 199 x 44 mm / Double Unit: 199 x 199 x 95 mm (without connectors, without mounting brackets)

264

Dual-Band Combiner
1710 2180 MHz
GSM1800 / PCS1900 / AWS / UMTS2100

2400 2700 MHz


WLAN / WiMAX / BRS/ LTE2600

Accessories (order separately)


Type No. 734360 734361 734362 734363 734364 734365 Clamp set suitable for mast diameter of 34 60 mm 60 80 mm 80 100 mm 100 120 mm 120 140 mm 45 125 mm

Clamp Set

Typical Attenuation Curves


Diagram I
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 10 20 1710 2180 30 40 50 2400 2700

DC stop

50-Ohm load
Type No. 78210850 78410367 Description DC stop 50-Ohm load

60 70 80 90 100 1500 1650 1800 1950 2100

2250 2400 2550 2700 2850 3000

Frequency/MHz

Diagram II
Port 1 Port 3 Port 2 Port 3

Attenuation/dB

0 0.1 0.2 1710 2180 0.3 0.4 0.5 2400 2700

Single Unit Side view

Double Unit Side view

0.6 0.7 0.8 0.9 1.0 1500 1650 1800 1950 2100

2250 2400 2550 2700 2850 3000

Frequency/MHz

Top view Single Unit Double Unit

Please note: The mounting plates can be removed by loosening the screws to (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

Bottom view Single Unit Double Unit

265

You might also like