POWER SUPPLY : 100~220VAC , 24VDC I/O : 10, 14, 20, 30 and 40 CPU type : E type (basic model) and N/NA (application model) Output : transistor and relay type Program capacity : 2K steps for E type and 8K steps for N/NA type Programming method : Ladder diagram
CP1L
POWER SUPPLY : 100~220VAC , 24VDC I/O : 10, 14, 20, 30, 40 and 60 CPU type : CP1L Output : transistor and relay type Program capacity : 10K steps and 20K steps Programming method : mnemonic code, ladder diagram, function block
CP1H
POWER SUPPLY : 100~220VAC , 24VDC I/O : 10, 14, 20, 30, 40 and 60 CPU type : CP1H Output : transistor and relay type Program capacity : 20K steps Programming method : mnemonic code, ladder diagram, function block
CX-Programmer V9.3 made in Japan Improvements on 87 points Designed to operate with MS Windows XP, Windows Vista and Windows 7 Recommended: Windows 7 New PLC ranges supported: - CJ1M - CS1H - CS1D - CP1E / L / H
Small selection: RS01 RS03 RS05 RS06 RS10 Key-function allocation Open CX-P with default environment On-line default state: Monitoring Auto on-line function Improvement to address formatting: A-AR, H-HR, L-LR, T-TIM, C-CNT, D-DM, E-EM RS11 Enable pasting of Symbol data created using MS-Excel and CX-P V1.2. RS16 Automatically generate an END instruction in a new section RS19 Fast connection across empty cells: [Ctrl] + arrow keys RS24 Connection and division of rungs RS35 Jump to corresponding contact / coil RS56 Rung Wrap RS86 Block / Network Manager
000.00
000.01
000.01
100.00
000.02
000.02
000.00
000.01
100.00
000.02
000.03
000.02
000.00
000.01
100.00
000.02
000.03
000.04
000.05
100.01
000.06
000.07
000.04
000.05
100.01
000.06
000.07
000.05
LD OR LD OR AND LD OUT
100.01
000.07
000.00
000.01
000.02
000.03
100.02
000.04
000.05
100.03
000.00
000.01
000.02
000.03
100.02
000.04
000.05
100.03
TEMPORARY RELAY
LD AND OUT TR AND AND OUT LD TR AND AND OUT 000.00 000.01 0 000.02 000.03 100.02 0 000.04 000.05 100.03
TRY...
1.
Define the purpose Problem Splitting Working out Design Writing Testing Finishing
2.
3.
4.
5.
6.
7.
1.
Products on the inputbelt are transported to PES 0.00. This belt stops if there is another product under work. Otherwise the product is transported to the next belt and stops if PES 0.01 detects the product. The drill is in the upper position and will be started by output 100.02. The drill goes down to limitswitch 0.02. The output 100.02 is set to off and the drill is returning to the upper position. If upperlimitswitch 0.03 detects the drill, the inputbelt, the transportbelt and the outputbelt is started. PES 0.04 detects the product and stops the outputbelt on the backside of the product . After five products the pusher is activated and pushes the products from the belt by output 100.04. If the pusher is in the out position (limitswitch 0.05) the output goes off and the pusher returns. During this period no belt is running except the inputbelt.
2.
In-take transport
Drilling station
2.
In-take transport Transport
Drilling station
Transport
Drilling
Transport
3.
000.00 000.01 000.02 000.03 000.04 000.05 000.06 100.00 100.01 100.02 100.03 100.04 FInput FTransp CilOut CilIn FOutput PusIn PusOut Minput MTransport ACyl MOutput APus
Product under work Product under work ready Move products Move products ready
TRY...
Operand Data-area S: Source word IR, SR, AR, HR, LR, T/C, DM, # P1: Parameter word IR, AR, HR, LR
Condition 3 P1
R
R: Result word
IR, AR, HR, LR, T/C, DM
Operand Data-area
N: TC number
# (000-511) SV: Set value (BCD) IR, AR, DM, HR, LR, #
P1 Time Contact
INPUT
SV
TIMER OUTPUT
SV
000.00
SV
100.00
SV
000.01
SV1
100.01
SV1
000.02
SV3
100.02
SV3 SV2
SV2
000.03
SV3
100.03
SV3
SV
SV Time Contact = 1 - 9999 = 0.01 - 99.99 sec = TIM0
INPUT
SV
TIMER OUTPUT
SV
Ladder symbol
Operand Data-area
Pulse
Reset
CNT
N SV
N: Counter number
# (000 511) SV: Set value (BCD) IR, AR, DM, HR, LR, #
SV Contact
= 1 - 9999 = CNT511
PULSE
5
RESET
COUNTER OUTPUT
Ladder symbol
Operand Data-area
II+
DIReset
CNTR(12)
N SV
SV Contact = 1 - 9999 = CNT511
N: Counter number
# (000 511) SV: Set value (BCD) IR, AR, DM, HR, LR, #
II+
DI-
0
RESET COUNTER OUTPUT
Try
Ladder symbol S R
Operand Data-area
KEEP(11)
B
000.00
B: Bit
IR, AR, HR, LR
000.01 100.00
100.00
Operand Data-area B: Bit IR, AR, HR, LR B: Bit IR, AR, HR, LR
Ladder symbol
Operand Data-area B: Bit IR, AR, HR, LR B: Bit IR, AR, HR, LR
Signal
DIFU(13) B
Signal
DIFD(14) B
CYCLUS
Signal
ILC(03)
ILC(03)
000.00
000.01
010.00
Try
First scan
1 min pulse 0.02 sec pulse 0.1 sec pulse 0.2 sec pulse 1.0 sec pulse