Guarding a wood processing center with SLSR 46B Single Light Beam Safety Devices and TNT 35 Test Monitoring Unit
TNT 35 is a Test Monitoring Unit for the periodic testing of "testable" optoelectronic protective devices. Both components, sensor and TNT 35, form an AOPD in accordance with IEC/EN 61496-1, -2. Up to 6 type 2 sensors can be connected to the TNT 35 via a series connection. In addition to testable Leuze electronic type 2 Single Light Beam Safety Devices, type 2 Single Light Beam Safety Devices of the MLD 300 series can also be connected. The machines functional sequence remains unimpaired by the periodic internal function tests.
TNT 35 p. 478
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
TNT 35
Important technical data, overview
Type in accordance with IEC/EN 61496 Performance Level (PL) in accordance with EN ISO 13849-1 Category in accordance with EN ISO 13849 Stop category in accordance with IEC/EN 60204-1 Supply voltage Response time Interval for periodic testing Max. number of type 2 sensors in series connection Safety-related switching outputs (OSSDs) Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D)
Type 2 PL d 2 0 24 V DC, 15% <20 ms 2s 6 (total response time of the sensor series connection, 60 ms) 2 relay outputs (NO) -20...+60C -30... +70C 45 mm x 99 mm x 113.6 mm
Functions
Test Monitoring Unit for periodic testing of type 2 sensors Multiple monitoring of type 2 sensors with series connection Start/restart interlock (RES), optionally with/without Static contactor monitoring (EDM), with/without optional "Safety on" signal output "Error" signal output
Features
Accessories
Special features
Constant cyclical testing every 2 s without process interruption of the machine function during the test 2 Safety Relay outputs with internal monitoring Selectable start and restart interlock status Selectable integrated contactor monitoring (EDM) LED indicators for all important functions and operating states Low space-requirement in the cabinet with compact construction
Ordering information Electrical connection Technical data Dimensional drawings Type 2 Single Light Beam Safety Devices
www.leuze.com/interfaces/
479
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Product Finder
Further information
Page
Glossary
Safety Relays
Safety Switches
Article TNT 35
TNT 35 p. 478
480
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
TNT 35
Electrical connection
TNT 35 connection example
+ 24V
+ 24V
-K1
w/ o RES
RES
L+ 1
L+ 1
-K2 -A1
1
-A2
-A3
14 15 16 22 23 24
21
13
29
31
MLD 300-T
MLD 312-R
TNT 35
State
6 Var. B Var. A
30
32
A1
A1
-K2
L0V PE
L0V PE
Test-berwachungseinheit TNT 35 Test Monitoring Unit with type 2 MLD 312 Multiple Light Beam Safety Device
Please observe the operating instructions of the components!
www.leuze.com/interfaces/
We reserve the right to make changes 15-05_TNT_35.fm
481
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Product Finder
Glossary
Accessories
-K1
A2
A2
Error
0V
0V
Safety Relays
+ 24V
OSSD
+ 24V
Start active
Test
Error reset
Safety Switches
On request On request 10,000,000 (2 A, 24 V) 100,000 (2 A, 230 V) 600,000 (1 A, 230 V) 1,300,000 (0.5 A, 230 V) On request
Category in accordance with EN ISO 13849 Mean time to dangerous failure (MTTFd) in accordance with EN ISO 13849-1 DCavg Type in accordance with IEC/EN 61496 Stop category in accordance with IEC/EN 60204-1 Interval for periodic testing Max. number of type 2 sensors in series connection Supply voltage Response time Sensor response time for test request Protection rating Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D) Mounting Connection system Current consumption Safety-related switching outputs (OSSDs) Switching voltage, switching current (for OSSDs) Connectable safety sensors (AOPDs)
72.6 years (TNT 35), 69 years (TNT 35 AC) 94.4 Type 2 0 2s 6 (total response time of the sensor series connection, 60 ms) 24 V DC, 15% <20 ms Time window 0.5 60 ms IP 40 (only suitable for use in electrical operating rooms/cabinets with IP 54 minimum protection rating) -20...+60C -30... +70C 45 mm x 99 mm x 113.6 mm on 35 mm DIN rail Cable gland, up to 2.5 mm2 Approx. 200 mA without external load 2 relay outputs (NO) Max. 250 V AC, max. 4 A Type 2 Single Light Beam Safety Devices, see 270
482
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
TNT 35
Technical data
Control inputs Receiver input Start/restart interlock (RES) Contactor monitoring (EDM) Control output Transmitter activation Signal outputs Safety on Safety with TNT 35/7-24V Error
pnp transistor output (high-active) pnp transistor output, 100 mA Potential-free relay contact pnp transistor output, 100 mA
Please note the additional information in the connecting and operating instructions and at www.leuze.com/interfaces.
Dimensional drawings
111
TNT35
99.0
TNT 35 Test Monitoring Unit Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.
www.leuze.com/interfaces/
We reserve the right to make changes 15-05_TNT_35.fm
483
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Product Finder
45
113.6
Glossary
Accessories
Safety Relays
Potential-free opto-coupling input (high-active), input current approx. 10 mA Potential-free opto-coupling input (high-active), input current approx. 10 mA Potential-free opto-coupling input (high-active), input current approx. 10 mA