Nothing Special   »   [go: up one dir, main page]

Datasheet PVRM3-103 Ha5118 EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Proportional Pressure Control Valve, Reducing - Relieving, Direct-Acting

PVRM3-103 M24x1.5  Qmax 40 l/min (11 GPM)  pmax 90 bar (1300 PSI)

Technical Features

› Excellent stability throughout flow range with rapid response to proportional current input change
› Low hysteresis, accurate pressure control and low pressure drop through CFD optimized flow paths
› Precise pressure control vs current and excellent repeatability
› Integrated relief function for protection against pressure peaks
› Solenoid electrical terminal AMP Junior Timer, or Deutsch D04-2P
› 12 or 24 V DC coils
› In the standard version, the valve is zinc-coated for 240 h protection acc. to ISO 9227.
Enhanced surface protection for mobile sector available for the steel parts (ISO 9227, 520 h salt spray)

Functional Description

A direct-operated, spool-type hydraulic pressure reducing-relieving valve in the form of a screw-in cartridge.
Reduced pressure in output (A) is proportional to DC current input. When the appliance is overloaded, the
circuit is protected against damage by high pressure by connecting it to the tank (channel T).
Note: Consult factory for special OEM versions of this product.

Model no mesh screen

Symbol

Technical Data

Valve size / Cartridge cavity M24x1.5 / QJ3


Max. operating pressure (port P) bar (PSI) 50 (730) 90 (1305)
Max. reduced pressure (port A) bar (PSI) 18 (260) 20 (290) 30 (435) 80 (1160)
Max. flow rate P-A l/min (GPM) 40 (11)
Fluid temperature range (NBR) °C (°F) -30 ... +90 (-22 ... +194), +100 (212) short-time
Fluid temperature range (FPM) °C (°F) -20 ... +90 (-4 ... +194), +100 (212) short-time
Ambient temperature range °C (°F) -30 ... +90 (-22 ... +194), +100 (212) short-time
Response time at 100 % signal ms < 50
Solenoid data
Supply voltage V 12 DC 24 DC
Limit current A 1.5 1
Rated resistance at 20 °C (68 °F) Ω 5 13.4
Duty cycle % 100
Optimal PWM frequency Hz 150
Quenching diode BZW06-28B BZW06-33B
Enclosure type acc. to EN 60529* (acc.to terminal type) IP67 / IP69K
Weight with solenoid kg (Ibs) 0.4 (0.88)
*The indicated IP protection level is only reached with a properly mounted connector.
Technical data of electronic control unit EL-7
Operating supply voltage Ucc V DC 9 ... 32
Reference voltage Uref V DC 5
Max. current at Uref mA 20
Types of input command signal, when EL7 is used see datasheet EL7*
Max. output current / 1 coil A 3
PWM frequency Hz 80 ... 1 000
Resolution of A/D converters bit 12
Ramp function s 0 ... 45
Dither – amplitude** % from Imax 0 ... 30
Dither – frequency** Hz 60 ... 300
**When the dither is activated, the PWM frequency is automatically set to 15 kHz.
Datasheet Type
General information GI_0060 Products and operating conditions
Cavity details SMT_0019 SMT-QJ3*
Spare parts SP_8010

Page 1 www.argo-hytos.com
Subject to change · PVRM3-103_5118_5en_03/2024
Ordering Code

PVRM3 - 103 / S - - -
Proportional pressure control
valve, reducing - relieving,
direct-acting
Surface treatment
Valve cavity A zinc-coated (ZnCr-3), ISO 9227 (240 h)
M24x1.5 / QJ3 B zinc-coated (ZnNi), ISO 9227 (520 h)

Model
screw-in cartridge

Max. reduced pressure Seals


18 bar (260 PSI) 18 No designation NBR
20 bar (290 PSI) 20 V FPM (Viton)
30 bar (435 PSI) 30
80 bar (1160 PSI) 80

Supply voltage / limit current


12 V DC / 1.5 A 12
24 V DC / 1 A 24 Connector
E1 EN 175301-803-A
Integrated electronic control unit E2 E1 with quenching diode
(standardly on the solenoid “a“) E3A AMP Junior Timer - axial direction (2 pins; male)
E4A E3A with quenching diode
Electronic control unit EL7-IA with an analogue input command signal EL7-A E12A Deutsch DT04-2P - axial direction
Electronic control unit EL7-IC for connection to the CAN bus EL7-C E13A E12A with quenching diode

Characteristics measured at ν = 32 mm2/s (156 SUS)

Reduced pressure related to control signal Reduced pressure related to control signal

Port A, range 0 - 20 bar (290 PSI), Q=0 lpm (GPM) Port A, range 0 - 80 bar (1160 PSI), Q=0 lpm (GPM)
Port P, inlet pressure 50 bar (730 PSI) Port P, inlet pressure 90 bar (1305 PSI)
(320) 22 (1450) 100
Pressure p [bar (PSI)]
Pressure p [bar (PSI)]

(290) 20 (1305) 90
20 bar 80 bar
(260) 18 (1160) 80
(230) 16 (1015) 70
(200) 14 (870) 60
(170) 12 (725) 50
(150) 10 (580) 40
(120) 8
(435) 30
(90) 6
(290) 20
(60) 4
(30) 2 (145) 10

0 200 400 600 800 1000 1200 0 100 300 500 700 900 1100

Current [I (mA)] Current [I (mA)]

Reduced pressure related to control signal Pressure drop related to flow rate
Port A, range 0 - 18 bar (260 PSI), Q=0 lpm (GPM) A-T, Valve coil de-energized (relieving function)
Port P, inlet pressure 50 bar (730 PSI) P-A, Valve coil energized (reducing function)

Port A, range 0 - 30 bar (435 PSI), Q=0 lpm (GPM)


Port P, inlet pressure 50 bar (730 PSI)
(479) 33 16
Pressure p [bar (PSI)]

(230)
Pressure drop Δp [bar (PSI)]

(435) 30
(200) 14
(392) 27 30 bar
(348) 24 (170) 12
A T
(305) 21 (150) 10
(261) 18
(120) 8
(218) 15 P A
18 bar
(174) 12 (90) 6
(131) 9 (60) 4
(87) 6
(44) 3 (30) 2

0 200 400 600 800 1000 0 4 8 12 16 20 24 28 32 36 40


(1.1) (2.1) (3.2) (4.2) (5.3) (6.3) (7.4) (8.5) (9.5)(10.6)
Current [I (mA)]
Flow Q [l/min(GPM)]

www.argo-hytos.com Page 2
Subject to change · PVRM3-103_5118_5en_03/2024
Elektronic control unit EL7

An electronic control unit (ECU) EL7 is used for the valve control. The ECU converts the input command signal into an output current control PWM
signal for solenoid coils. The ECU EL7 is available as external for connection to the DIN rail (EL7-E, see datasheet HA 9152) or integrated on the valve
in the form of connector plug (EL7-I, see datasheet HA 9151).

Dimensions in millimeters (inches)

Connector type Vent screw


E3, E4 - IP67 E12A, E13A - IP67 / IP69K only for version with
AMP Junior Timer Deutsch DT04-2P reduced pressure 80 bar

20+5Nm
(14.7+3.7 lbf.ft)

4+1 Nm 1+0.5 Nm
(3+0.7 lbf.ft) (0.7+0.4 lbf.ft)

Page 3 www.argo-hytos.com
Subject to change · PVRM3-103_5118_5en_03/2024