3 Bse 062937 en A System 800xa 5.1 Product Catalog
3 Bse 062937 en A System 800xa 5.1 Product Catalog
3 Bse 062937 en A System 800xa 5.1 Product Catalog
1 Product Catalog
Contents
System 800xA Extended Automation The Power of Integration System 800xA Software System 800xA Hardware S900 I/O
4 7
57
Redundant Termination Unit .................................................. 58 Power supply ....................................................................... 58 Communication interface ...................................................... 59 Digital I/O modules ............................................................... 59 Solenoid driver ..................................................................... 60 Relay output ......................................................................... 60 Frequency input .................................................................... 61 Analog input ......................................................................... 61 Temperature input ................................................................. 63 Analog output ....................................................................... 63 Field housing ........................................................................ 65 Compact box ....................................................................... 67 Power supply for CB220x ..................................................... 67 Accessories for S900 Remote I/O .......................................... 68 Base System .......................................................................... 8 Base System Options ............................................................. 9 Connectivity ......................................................................... 11 800xA Engineering ................................................................ 12 IEC 61850 Engineering ......................................................... 13 Media................................................................................... 14 Device Management & Fieldbuses ......................................... 15 Process Automation Control .................................................. 16 Safety .................................................................................. 16 Asset Optimization ................................................................ 17 Batch Management .............................................................. 18 Information Management ...................................................... 19 Localization .......................................................................... 21
71
27
77
AC 800M Controllers and users guide .................................... 28 AC 800M Controllers ............................................................ 30 AC 800M High Integrity Controllers ........................................ 31 Communication .................................................................... 32 Network components............................................................ 37 Power Supply ....................................................................... 38 Mounting Rails ...................................................................... 39
System 800xA - Media .......................................................... 78 Solutions - Media ................................................................. 78 Dongles ............................................................................... 79 800xA Base System User Documentation .............................. 79 Connectivity ......................................................................... 80 Operations User Documentation ............................................ 82 Batch Management User Documentation ............................... 82 Information Management User Documentation ....................... 82 Asset Optimization User Documentation ................................ 83
41
Engineering User Documentation ........................................... 83 Control and I/O User Documentation ..................................... 84 Safety User Documentation ................................................... 85 S900 I/O .............................................................................. 85 Device Management and Fieldbus User Documentation .......... 86 Network User Documentation ................................................ 86 Reference documentation ..................................................... 87
S800 I/O modules Users guide ........................................... 44 Communication .................................................................... 45 Modulebus Communication Parts .......................................... 46 S800 I/O Modules ................................................................. 48 High Integrity I/O Modules ..................................................... 52 Module Termination Units ...................................................... 53 S800L I/O Modules ............................................................... 55
Operations Engineering Device Management Asset Optimization Batch Management Information Management
Plant Network, ERP, CMMS...
System Networks
System Workplaces
Panel 800
WirelessHART Gateway
MODBUS
IEC 61850
Modulebus
Motor Controller
S800 I/O
LV Switchgear
Power Automation
Process Electrification
Process Instrumentation
WirelessHART
Safety
System 800xA
ABBs award winning System 800xA provides you with a better way to achieve measurable productivity and profitability improvements. System 800xA extends the scope of traditional DCS systems to include all automation functions in a single operations and engineering environment; enabling your plants to perform smarter and better at substantial cost savings. System 800xA delivers extended productivity gains by: Reducing time to decision and action Engineering for maximum performance Reducing risk through high integrity automation Integrating information for improved visibility Improving batch production profitability, consistency, and traceability Optimizing plant asset availability and performance Delivering Control and I/O to meet automation and safety needs Extending installed system capabilities through seamless evolution Embracing the principles of open, real-time networking, System 800xA provides a scalable solution that spans and integrates loop, unit, area, plant, and inter plant controls. From providing a secure foundation with robust, but flexible, base level regulatory and sequence control to higher level management and advanced control functions that include safety controls,batch management, maintenance management, information management, and network management solutions, System 800xA meets the application needs of a wide variety of industries. System 800xA provides you with a secure, reliable control environment with minimum effort through built-in security features such as access control, user authentication, and audit trail capability. ABB enhances secure system operations by actively participating on security standards committees, conducting threat-modeling studies, and incorporating safe design practices into product development. Based upon the Aspect Object technology and a common set of hardware, System 800xA seamlessly integrates traditionally isolated DCS and Safety systems. SIS realization is achieved by either utilizing individual controllers or through dedicated applications within the same controller. With this embedded control and safety architecture, System 800xA reduces costs significantly; achieving the objectives of both systems maximum plant availability at minimum risk.
The 800xA System software is packaged in a set of DVDs. The system installation is supported by the Automated Installation program. The Automated Installation program is a shell framework to ease the installation and configuration of your 800xA System. Installation is never prevented due to lack of licensing, but licenses are required to unlock features for operating or engineering the system. Updates and security related software from non-ABB companies must be downloaded and installed separately, as guided from the Automated Installation program. The Automated Installation program is supplied on the system DVD. The common part is to specify the system details of your system in the Automated Installation program System Planner and generate a unique setup package for each node (workstation) describing what should be installed from the DVDs, or a file server, onto each node, and how it should be configured. The System 800xA Installer is installed on each node, and then the following steps are executed to install and configure your node: Windows configuration. System Verifier tool. System installation. System configuration.
The setup-files may also reside on the file server. Windows configuration configures the environment (IP address, hostname, Windows components, and Windows services) connect to the workgroup or domain. The System Verifier tool checks for the necessary 3rd party software and where installations are required.
License
The central licensing system (CLS) is local to each system. Each system is ordered separately, and a separate license file is fetched for each system from the Software Factory. This also means that each system is managed individually updates and upgrades, as well as initial system installation The software or hardware described in the document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
DVD Formats
The 800xA software is delivered on dual layer DVDs. In most instances, DVD readers from 2004 and later will be able to read this format. In those instances where the dual layer format can not be read, the recommendation is to purchase an USB DVD reader capable of reading dual layer DVDs.
Base System
800xA Base System 800xA 5.1 Includes one Operator Workplace, one Engineering Workplace, AC 800M Connectivity, Redundant Aspect Server, Plant Explorer, Topology Status Viewer, Softpoint Server, Scheduler, Primary History Logs (logging of signals for operator trends for up to 3 months), 10 Asset Monitors and Diagnostics Collection. Fast log-over of users.
Article no. 800xA Base System 3BSE061234R1
Tag Addition All process objects with faceplate for operator interactions counts as a tag. (Total max 120,000. Can not be mixed with redundant tags). NOTE: A TSA is NEEDED for a system with more than 60,000 tags.
Non-redundant Tags 100 tags, non-redundant, 800xA 5.1 1,000 tags, non-redundant, 800xA 5.1 10,000 tags, non-redundant, 800xA 5.1 Article no. 3BSE061235R1 3BSE061235R2 3BSE061235R3
Redundant Tags 100 tags, redundant, 800xA 5.1 1,000 tags, redundant, 800xA 5.1 10,000 tags, redundant, 800xA 5.1
Operator Workplaces
Article no. Operator Workplace - Additional Client, 800xA 5.1 Includes Excel based reporting aspects, MS Excel is NOT included. Possibility to use up to two screens per workplace. (One Operator Workplace is included with Core System so this limit to Total-1). The total quantity of Operator WorkplaceAdditional and Remote Clients, Large Operator Workplaces and Engineering Workplaces - must not exceed 55. Operator Workplace - Remote Client, 800xA 5.1 Terminal server must be bought separately. Does not support Excel based reporting aspects. The total quantity of Operator Workplace - Additional and Remote Clients, Large Operator Workplaces and Engineering Workplaces - must not exceed 55. Large Operator Workplace, 800xA 5.1 Includes one Operator Workplace with the possibility to use up to four screens per workplace and/or large desktop functionality. The total quantity of Operator Workplace Additional and Remote Clients, Large Operator Workplaces and Engineering Workplaces - must not exceed 55. 3BSE061257R1 3BSE061256R1 3BSE061255R1
Structured Data Logger Makes it possible to store data sets in a SQL DB, triggered by the Controller. Scaled on number of Data Logs, each defining a set of properties logged for a specific processing step. Total max 200 Data Logs.
Article no. 10 Structured Data Logs, 800xA 5.1 3BSE061253R1
Connectivity
Connectivity Note that there may be 800xA price list options that are not supported with a particular OCS controller. Please refer to the table Available functions per Controller Connectivity in the System Guide Technical Data and Configuration Information. To check what connectivity combinations that are valid, use the Project Wizard or refer to the System 800xA System Guide for information.
Article no. 800xA for Advant Master, 800xA 5.1 (One per system.) RTA hardware needs to be ordered separately. Please refer to pricebook 3BSE001706, Advant OCS with Master Software, for RTA hardware. 800xA for MOD 300, 800xA 5.1 (One per system.) RTA hardware needs to be ordered separately. Please refer to pricebook 3BSE001709, Advant OCS with MOD 300 SW, for RTA hardware. 800xA for Harmony, 800xA 5.1 (One per system.) 800xA for AC 870P / Melody, 800xA 5.1 (Faceplates not included). (One per system.) PLC Connect, 800xA 5.1 (One per system.) PLC Connect Dial-Up, 800xA 5.1 (One per serial communication channel used with dialed communication. PLC Connect is required. Scaled on number of dial up lines in a system). 800xA for Safeguard, 800xA 5.1 (One per system.) Requires also 800xA for Advant Master. 3BSE061244R1 3BSE061243R1 3BSE061242R1 3BSE061240R1 3BSE061239R1 3BSE061238R1 3BSE061237R1
IEC 61850 Connect For order of IEC 61850 related products, local organizations must comply with the Demands on the Purchaser to secure successful sales of IEC 61850 with System 800xA. Ref doc, 3BSE058798.
Article no. IEC 61850 Connect, 800xA 5.1 Allows clients to access data directly from Intelligent Electrical Devices (IEDs). Handles alarms from IEDs. Includes one IEC 61850 OPC server. At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. Redundant IEC 61850 Connect Option, 800xA 5.1 Allows clients to access data through redundant Connectivity Servers from Intelligent Electrical Devices (IEDs). Handles alarms from IEDs. Includes one additional IEC61850 OPC server. Requires IEC 61850 Connect. The number of Redundant IEC 61850 Connect licenses shall be the less than or equal to the number of IEC 61850 Connect Options, when redundancy is chosen . At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 3BSE061370R1 3BSE061369R1
800xA Engineering
Standard Engineering Options
Article no. Engineering Workplace - Additional Rich Client, 800xA 5.1 Includes Control Configuration for AC 800M, Bulk Data Handling, and Graphic Configuration, Document Manager, Parameter Manager, I/O allocation function and Script Manager Professional. One Engineering Workplace is included with the 800xA Base System. The total quantity of Operator Workplace-Additional and Remote Clients, Large Operator Workplaces and Engineering Workplaces - must not exceed 55. Load Evaluate Go, 800xA 5.1 Allows the user to modify, download and evaluate a version of a running application to an AC 800M Controller without interfering with the running application version. THIS ITEM NEEDS A TSA TO BE ORDERED SoftController, 800xA 5.1 To be used with the programming tool Control Builder M. This product is to be used as a test tool only. One license is required per SoftController. Separate Base System for Engineering Including Base System for 60,000 tags, one Engineering Workplace, one Operator Workplace, Connectivity -, System Data Publishing - , and System Options functions. 3BSE061375R1 3BSE061344R1 3BSE061343R1 3BSE061342R1
One-year Renewal The IEC 61850 Engineering Tool license needs to be renewed on a yearly basis.
Article no. IEC 61850 Engineering Tool for 800xA Renewal for internal use THIS ITEM NEEDS A TSA TO BE ORDERED. 3BSE054535R1
IEC 61850 Engineering License End Customer use This license is intended for cases when the End Customer wants to be in control of this application and requires ABB (or the Channel Partner) to deliver a full set of engineering tools with the delivery. This license is one-time fee (no renewal is necessary). Delivery of an End Customer license requires an approved TSA.
Article no. IEC 61850 Engineering Tool for 800xA - for End Customer 3BSE054253R1
Media
Media for IEC 61850 Engineering Tool for 800xA - Internal ABB use
Article no. IET - Integrated Engineering Toolbox For Internal Use. Includes CCT - Communication Configuration Tool. THIS ITEM NEEDS A TSA TO BE ORDERED. 3BSE054539R1
Media for IEC 61850 Engineering Tool for 800xA - End Customer use
Article no. CCT - Communication Configuration Tool For External Use. THIS ITEM NEEDS A TSA TO BE ORDERED. 3BSE054927R1
Device Management FOUNDATION Fieldbus For FOUNDATION Fieldbus (FF) devices to be accessed using Fieldbus Builder FF within System 800xA. Includes FF Device Library with FF Device Aspect Objects, FF Instruments Asset Monitor Library and OPC Server. Each FF device aspect object counts as one. (Max 1000 per Connectivity Server. For details refer to System Guide.)
Article no. 100 FF Device Aspect Objects, 800xA 5.1 1000 FF Device Aspect Objects, 800xA 5.1 10000 FF Device Aspect Objects, 800xA 5.1 3BSE061363R1 3BSE061364R1 3BSE061365R1
Device Management PROFIBUS For PROFIBUS DP/PA devices to be accessed using Device Type Manager (DTMs) within System 800xA. Includes PROFIBUS Device Library with specific PROFIBUS Device Aspect Objects incl. DTMs, I/O DTM for S800 and S900, and PROFIBUS Instruments Asset Monitor Library. Each PROFIBUS device aspect object accessed with DTM counts as one. (Max 2500 per Connectivity Server if OPC communication is used. For details refer to System Guide.)
Article no. 100 PROFIBUS Device Aspect Objects, 800xA 5.1 1000 PROFIBUS Device Aspect Objects, 800xA 5.1 10000 PROFIBUS Device Aspect Objects, 800xA 5.1 3BSE061366R1 3BSE061367R1 3BSE061368R1
Article no. PM851 to PM856 Software Expansion License, 800xA 5.1 PM856 to PM860 Software Expansion License, 800xA 5.1 PM860 to PM861/PM861A Software Expansion License, 800xA 5.1 PM861/PM861A to PM864/PM864A Software Expansion License, 800xA 5.1 PM864/PM864A to PM866 Software Expansion License, 800xA 5.1 PM866 to PM891 Software Expansion License, 800xA 5.1 3BSE061909R1 3BSE061908R1 3BSE061907R1 3BSE061904R1 3BSE061904R1 3BSE061906R1
Safety
Article no. AC 800M High Integrity and Process Control, 800xA 5.1 One fixed license feature per AC 800M controller running both non-SIL and SIL applications in the same controller. 3BSE061341R1
Asset Optimization
Asset Optimization
Article no. 100 Asset Monitors, 800xA 5.1 Asset monitoring and Basic Asset Monitor Library. Each Aspect Object being monitored by one or more asset monitors counts as one. 1000 Asset Monitors, 800xA 5.1 Asset monitoring and Basic Asset Monitor Library. Each Aspect Object being monitored by one or more asset monitors counts as one. Generic Heat Exchanger Asset Monitor, 800xA 5.1 It monitors the performance against standard operating parameters independent of type of heat exchanger. Shell and Tube Heat Exchanger Asset Monitor, 800xA 5.1 It monitors the performance against standard operating parameters based on the size of shell and tube heat exchanger. Advanced Harmony Control System Monitoring, 800xA 5.1 Enables Harmony Control Network monitors for diagnostic monitoring, reporting, and analysis. Control Loop Asset Monitor, 800xA 5.1 Each Control Loop Asset Monitor monitors up to 14 different loop conditions. This option gives the user the ability to monitor up to 100 loops. PC, Network and Software Monitoring, 800xA 5.1 Enables monitoring & supervision of IT assets. 800xA Maximo Integration, 800xA 5.1 Enables integration into Maximo for work order management. Application Engineering available through ConsultIT. At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 800xA SAP / Plant Maintenance Integration, 800xA 5.1 Enables integration into SAP for work order management. Application Engingeering available through ConsultIT. At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 3BSE061358R1 3BSE061357R1 3BSE061356R1 3BSE061355R1 3BSE061354R1 3BSE061353R1 3BSE061352R1 3BSE061351R1 3BSE061350R1
Batch Management
Batch Management
Article no. Batch Base System, 800xA 5.1 Provides the basic server functionality for batch management. The batch server includes 10 Batch Equipment and 2000 Batch Procedures. 1 Batch client included. Redundant Batch Server Option, 800xA 5.1 Provides redundancy for the basic server functionality for batch management. (Requires Batch Base System, 3BSE061258R1) Batch Management Full Client, 800xA 5.1 This Client feature provides access to Batch Management functions. The Client feature is based upon concurrent users, not physical workstation installation. Including SL and SQL server licenses. Requires Operator Workplace Client - 3BSE061255R1, 3BSE061256R1 or 3BSE061257R1; or Engineering Workplace Client - 3BSE061342R1. Maximum 40. One Client is included with the Batch Base System. Batch Schedule Interface, 800xA 5.1 This feature is used to interface Batch Management to external applications such as schedulers and ERP systems. XML interface to batch schedule and equipment status. This is part of the Batch Web Interface. 10 Additional Batch Equipment, 800xA 5.1 The number of batch equipment instances includes each piece of equipment configured in Batch Management including both Units and Shared Equipment Modules. 100 Additional Batch Equipment, 800xA 5.1 The number of batch equipment instances includes each piece of equipment configured in Batch Management including both Units and Shared Equipment Modules. Batch Advanced Phase Templates, 800xA 5.1 This feature provides access to the batch advanced templates control modules for phases, units and shared equipment modules. For use with AC 800M controllers. Batch Phase Control library option, includes 2000 Advanced Phases. 3BSE061264R1 3BSE061263R1 3BSE061262R1 3BSE061261R1 3BSE061260R1 3BSE061259R1 3BSE061258R1
Information Management
Basic Historian Logging of signals for Operator trends is included in the core system for up to three months. Logging for a longer time period, archiving to external media like DVD, discs or web based Historian tools require Historian server. Max 120,000 logs allowed in one server. (Includes archiving license, PDL, up to 12,000,000 events, MDI client and one Excel Data Access).
Article no. Basic Historian Server, 800xA 5.1 With storage and archiving functions for: history data, events (Message Log), and production data (Production Data Log-PDL). Includes Licenses for: 500 History Logs one Multi-Display Interface (MDI) client one Display Builder for MDI one Desktop Trend client one Excel Data Access Batch reports with trending requires an additional licensed option, see Historian Data Access Options. 3BSE061265R1
History Logs Number of initial Information Management Hierarchical Logs in the system. Each signal to be logged counts as one log. Note: Information Management provides only Hierarchical Logs. (Total max 300,000 and max 50,000/Server.)
Article no. 100 History Logs, 800xA 5.1 1,000 History Logs, 800xA 5.1 15,000 History Logs, 800xA 5.1 3BSE061266R1 3BSE061267R1 3BSE061268R1
Dual History Logs For parallel logging in two history servers. (Two Basic Historian Servers are required). Number of initial Information Management Hierarchical Logs in the system. Each signal to be logged counts as one log. Note: Information Management provides only Hierarchical Logs. (Total max 150,000 and max 50,000/Server.)
Article no. 100 Dual History Logs, 800xA 5.1 1,000 Dual History Logs, 800xA 5.1 15,000 Dual History Logs, 800xA 5.1 3BSE061269R1 3BSE061270R1 3BSE061271R1
Information Management
Consolidated History Logs Consolidated logs collect data from multiple History Servers and store it in a single location. This provides a common history repository for viewing and reporting. (Total max 300,000 and max 50,000/Server.)
Article no. 100 Consolidated History Logs, 800xA 5.1 1,000 Consolidated History Logs, 800xA 5.1 15,000 Consolidated History Logs, 800xA 5.1 3BSE061328R1 3BSE061329R1 3BSE061330R1
Historian Data Access Options To access historical data through SQL from third party applications. Batch Reports with trending requires the ODBC Server (3BSE061335R1) and ODBC Client (3BSE061336R1) option. This option provides the links necessary to connect the Oracle database (PDL) and the numeric log and process data. Applications which utilize commercial third party reporting tools should also include the ODBC Server (3BSE061335R1) and ODBC Client (3BSE061336R1) option. The number of client connection is based on whether the applications utilizes the connection directly or indirectly. If the connection is made indirectly (using Oracle), then the client connection requires is only one. If the client connections are direct, then the number of clients should equal the number of concurrent users.
Article no. Excel Data Access, 800xA 5.1 To access historical data through SQL from third party applications. Used to access historical data in Excel from non 800xA PCs. For 800xA Client PCs Excel Data Access is included. (Max 64 per Server). ODBC Historical Data Server, 800xA 5.1 ODBC, includes third party code. (One per server.) ODBC Client Connection, 800xA 5.1 ODBC Clients are purchased separately from the ODBC server. (Max 10 per ODBC Server.) 3BSE061336R1 3BSE061335R1 3BSE061334R1
Localization
National Language Support (NLS) is intended for the localization of the operator interface to the desired language. NLS contains a set of functions that are harmonized with the Windows regional settings to enable a multilingual environment for the System 800xA. The System 800xA supports translations, mainly the operator interface and the operator manuals as shown in the Table 3 and Table 4. The translation, or System 800xA Language Package, is implemented as a system extension and is possible to install without stopping the system. The NLS Localization Guide describes what and how localization can be performed by a project with or without an installed Language Package. The English version of the Windows operating system is required. The System 800xA Language Packages can be downloaded free of charge from ABB Library.
Table 3. Supported Language Packages for Functional Areas Functional Areas SMS & eMailing FOUNDATION FIELDBUS ** Information Management Base System Batch Management *Asset Optimization
Safety
Language Packages
Yes
Yes Yes
Yes Yes
Yes Yes
Yes
Yes Yes
Yes
Table 4. Supported Language Packages for Connectivity Connectivity 800xA for Advant Master
PLC Connect
Language Packages
Yes Yes
Yes
Yes
Yes
* IEC 61850
Localization
System 800xA Language Package
Article no. System 800xA 5.1 Chinese Language Package System 800xA 5.1 French Language Package System 800xA 5.1 German Language Package System 800xA 5.1 Russian Language Package System 800xA 5.1 Spanish Language Package System 800xA 5.1 Swedish Language Package 9ARD183928-001 9ARD183928-002 9ARD183928-003 9ARD183928-004 9ARD183928-005 9ARD183928-006
Article no. Extended Operation in Chinese Extended Operation in French Extended Operation in German Extended Operation in Russian Extended Operation in Spanish Extended Operation in Swedish 3BSE036904-510 3BSE036904-510 3BSE036904-510 3BSE036904-510 3BSE036904-510 3BSE036904-510
Article no. NLS installation manual NLS localization guide 2PAA102031 2PAA101940
Software Management
Automation Sentinel Program Renewals
Article no. One Year Renewal from a valid Sentinel Agreement A completed Automation Sentinel Audit Sheet 3BSE048558 must be submitted with all renewal orders. 3BSE047682R1
Article no. Type I subscription (1-2 concurrent users) to Automation Sentinel Type II subscription (3-5 concurrent users) to Automation Sentinel Type III subscription (6-10 concurrent users) to Automation Sentinel Type IV subscription (11-20 concurrent users) to Automation Sentinel Type V subscription (> 20 concurrent users) to Automation Sentinel Concurrent Users - The number of Clients and Remote Clients plus one Client from the Core System 3BSE047685R1 3BSE046753R1 3BSE046752R1 3BSE046751R1 3BSE046750R1 3BSE046749R1
Article no. Batch add-on subscription to Automation Sentinel History add-on subscription to Automation Sentinel Safety add-on subscription to Automation sentinel RTPI add-on subscription to Automation Sentinel Includes an Automation Sentinel subscription for Real-TPI as add-on for a control system. Harmony Gateway add-on subscription to Automation sentinel 3BSE057510R1 3BSE046754R1 3BSE046755R2 3BSE051756R1 3BSE051802R1
Software Management
Library Extensions Renewal Depending on type of subscriptions (Type I to Type V), add up the sum of used libraries for each year. The 800xA Extension Application Libraries (PC Equipment, PC Device and ProBase) are included as part of the Automation Sentinel subscription and require ordering the articles below. The 800xA Evolution libraries (INFI 90 and MOD 300) are also included as part of the Automation Sentinel subscription but are included at no additional cost and do not require ordering the articles. Please refer to the Product Guide (3BSE047996) for the specific libraries supported.
Article no. Number of Libraries, Type I Subscription Number of Libraries, Type II Subscription Number of Libraries, Type III Subscription Number of Libraries, Type IV Subscription Number of Libraries, Type V Subscription 3BSE058750R1 3BSE058751R1 3BSE058752R1 3BSE058753R1 3BSE058754R1
Non-ABB Operator Workplace Renewal (See Automation Sentinel Product Guide 3BSE047996 for definitions)
Article no. Type I subscription (1-2 concurrent users) to Automation Sentinel Includes 5 technical phone support hours. Type II subscription (3-5 concurrent users) to Automation Sentinel Includes 10 technical phone support hours. Type III subscription (6-10 concurrent users) to Automation Sentinel Includes 15 technical phone support hours. Type IV subscription (11-20 concurrent users) to Automation Sentinel Includes 20 technical phone support hours. Type V subscription (> 20 concurrent users) to Automation Sentinel Includes 25 technical phone support hours. 3BSE051634R1 3BSE051633R1 3BSE051632R1 3BSE051631R1 3BSE051630R1
Article no. Stand-alone engineering tools, one per engineering tool product (See Automation Sentinel Product Guide 3BSE047996 for definitions, including pricing examples). Note: For 800xA Engineering tools in Classic requires purchase of the Extended Coverage Option. RTPI add-on subscription to Automation Sentinel Includes an Automation Sentinel subscription for Real-TPI as a Stand-alone Product. 3BSE051802R2 3BSE051629R1
Software Management
Extended Coverage for 800xA Extended Support for 800xA Software Versions.
Article no. Classic support for 800xA Extended Classic support for 800xA 3BSE046756R2 3BSE046757R2
Renewal Synchronisation Agreement See Automation Sentinel Product Guide 3BSE047996 for definitions. Please contact your local salesperson or visit www.abb.com/controlsystems.
Automation Sentinel Program New Subscriptions See Automation Sentinel Product Guide 3BSE047996 for definitions. Please contact your local salesperson or visit www.abb.com/controlsystems.
PM891
AC 800M
PM861A PM861AK01 incl: 1 PM861A CPU and required optional items PM861AK02 incl: 2 PM861A CPUs and required optional items No 48 MHz 16 MB 8.289 MB
PM864A PM864AK01 incl: 1 PM864A CPU and required optional items PM864AK02 incl: 2 PM864A CPUs and required optional items No 96 MHz 32 MB 25.049 MB
PM865 PM865AK01 incl: 1 PM865K01 CPU and required optional items PM865AK02 incl: 2 PM865K02 CPUs and required optional items Yes 96 MHz 32 MB 25.044 MB 23.850 MB w SM810 23.804 MB w SM811 Yes
PM866 PM866K01 incl: 1 PM866 CPU and required optional items PM866K02 incl: 2 PM866 CPUs and required optional items No 133 MHz 64 MB 52.996 MB
PM891 PM891K01 incl: 1 PM891 CPU and required optional items PM891K02 incl: 2 PM891 CPUs and required optional items No 450 MHz 256 MB 240 MB
High Integrity Controller Clock frequency Memory (RAM) RAM available for application
No 24 MHz 8 MB 2.787 MB
No 24 MHz 8 MB 2.787 MB
No 48 MHz 8 MB 2.787 MB
CPU redundancy support No Communication interfaces Performance, 1000 boolean operations (a:=b and c) Recommended Control Network backbone Dimensions Weight (including base) 1100 g (2.4 lb)
No
No
Yes
Yes
Yes
1 Ethernet port 2 Ethernet ports 2 Ethernet ports 2 Ethernet ports 2 Ethernet ports 2 Ethernet ports 2 RS-232C ports 2 RS-232C ports 2 RS-232C ports 2 RS-232C ports 2 RS-232C ports 2 RS-232C ports 0.46 ms 0.46 ms 0.23 ms 0.23 ms 0.15 ms 0.15 ms
0.043 ms
100 Mbit/s - 1 Gbit/s Ethernet (IEEE 802.3) W 119 x H 186 x D 135 mm (4.7 x 7.3 x 5.3 in.) 1100 g (2.4 lb) 1100 g (2.4 lb) 1200 g (2.6 lb) 1200 g (2.6 lb) 1200 g (2.6 lb) 1200 g (2.6 lb) W 174 x H 186 x D 94 mm 1600 g (3.5 lb)
Environmental Data for AC 800M and S800 I/O Climatic Operating Conditions Protection class Corrosive protection Electromagnetic Compatibility and CE-mark Electromagnetic Emission Electromagnetic Immunity Electrical Safety Hazardous Classified Locations Hazardous Classified Locations ATEX Safety Integrity (IEC 61508) 0 to +55 C (Storage -40 to +70C), RH = 5 to 95 % no condensation, IEC/EN 61131-2 IP20 according to EN 60529, IEC 529 G3 compliant according to ISA-71.04 Meets EMC directive 2004/108/EC according to EN 61000-6-2 and EN 61000-6-4 Tested according to EN 61000-6-4 EMC Generic Emission Standard, Part 2 Industrial Environment Tested according to EN 61000-6-2 EMC Generic Immunity Standard, Part 2 Industrial Environment UL508, IEC/EN 61131-2 UL/CSA 60079-15 (Class 1 Zone 2) S890 series of I/O modules: Category 3 (1) G, EEx nA [ia] IIC T4 PM865, AI880A, DI880, DO880: IEC 61508 up to SIL3
Measurements
CPU
115 (25.4) 135 (5.3)
PM891
174 94
186 (7.3)
186
AC 800M Controllers
AC 800M Processor Units
Article no. PM851K01 Processor Unit Package including: - PM851, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - Battery for memory backup (4943013-6) PM856K01 Processor Unit Package including: - PM856, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - Battery for memory backup (4943013-6) PM860K01 Processor Unit Package including: - PM860, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - Battery for memory backup (4943013-6) PM861AK01 Processor Unit Package including: - PM861A, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - TB852, RCU-Link terminator - Battery for memory backup (4943013-6) PM861AK02 Redundant Processor Unit Package including: 2 pcs PM861AK01, Processor unit. 1 pcs TK850, CEX-bus expansion cable. 1 pcs TK851, RCU-Link cable. 3BSE018160R1 3BSE018157R1 3BSE018100R1 3BSE018104R1 3BSE018168R1
PM864AK01 Processor Unit Package including: - PM864A, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - TB852, RCU-Link terminator - Battery for memory backup (4943013-6) PM864AK02 Redundant Processor Unit Package including: 2 pcs PM864AK01, Processor unit. 1 pcs TK850, CEX-bus expansion cable. 1 pcs TK851, RCU-Link cable.
3BSE018161R1
3BSE018164R1
AC 800M Controllers
Article no. PM866K01 Processor Unit Package including: - PM866, CPU - TP830, Baseplate, width = 115 mm - TB850, CEX-bus terminator - TB807, ModuleBus terminator - TB852, RCU-Link terminator - Battery for memory backup (4943013-6) PM866K02 Redundant Processor Units Package including: 2 pcs PM866K01, Processor unit. 1 pcs TK850, CEX-bus expansion cable. 1 pcs TK851, RCU-Link cable. 3BSE050199R1 3BSE050198R1
PM891K01 Processor Unit Package including: - PM891 CPU Module - TB850, CEX-bus terminator - TB853, RCU Control Link Terminator
3BSE053241R1
PM891K02 Redundant Processor Units Package including: 2 pcs PM891K01 Processor Unit 1 pcs TK850V007 CEX-bus Extension Cable 1 pcs TK855 RCU Data Link Cable 1 pcs TK856 RCU Control Link Cable Please note: The BC810K02 is not included in the PM891K02 Redundant Processor Unit kit. In order to make hot replacement of PM891 Processor Unit possible, the BC810K02 is required and has to be ordered separately. SB822 Rechargeable battery unit External DIN-rail mounted rechargeable battery unit including lithium-ion battery, 24 V DC connector and connection cable TK821V020. Width = 85 mm. Equivalent amount of Lithium metal = 0,8 g (0,03 oz).
3BSE053242R1
3BSE018172R1
Extra Batteries
Article no. Lithium Battery 3,6 V, 900 mAh Size 14.5 x 25 mm. Extra battery for PM851, PM856, PM860, PM861A, PM864A, PM865 and PM866. Not for PM891. 4943013-6
Extra Batteries
Article no. Lithium Battery 3,6 V, 900 mAh Size 14.5 x 25 mm. Extra battery for PM851, PM856, PM860, PM861A, PM864A, PM865 and PM866. Not for PM891. 4943013-6
Communication
Foundation RS-232 C Fieldbus CI860 HSE (H1 via Linking Device) CI853
MB300 CI855
MODBUS MB300 master, Comli master/slave, Siemens master, User defined protocols 75 - 19 200 b/s 10 Mbits/s, 200 Datasets/s
Transmission speed
10/100 Mbits/s
10 Mbits/s
4 Mbits/s
10/100 Mbits/s
Yes
Yes
Yes Fiber-optic
Yes BNC
Transmission speed
1,5 Mbit/s
10/100 Mbit/s
10/100 Mbit/s
Yes
Yes
Measurements
Communication Interface
58 (2.3) 127.5 (5.0)
186 (7.3)
Communication
Serial Communication Interface RS232-C interfaces for protocols COMLI, MODBUS, Siemens 3964R, the free-programmable serial protocol etc.
Article no. CI853K01 Dual RS232-C interface Package including: - CI853, Communication Interface - TP853, Baseplate, width = 60 mm 3BSE018103R1
MODBUS TCP
Article no. CI867K01 MODBUS TCP Interface Package including: - CI867 , Communication Interface - TP867 , Baseplate, width = 60 mm 3BSE043660R1
PROFIBUS DP The required PROFIBUS network components (Linking Devices, etc) must be ordered from price list 3BDD 013 232, PROFIBUS Network Components.
Article no. CI854AK01 PROFIBUS DP-V1 Communication interface Package including: - CI854A, Communication Interface - TP854, Baseplate, width = 60 mm 3BSE030220R1
PROFINET IO
Article no. CI871K01 PROFINET IO Communication Interface Package including: - CI871, Communication Interface - TP867, Baseplate width = 60 mm 3BSE056767R1
Ethernet/IP
Article no. CI873K01 Ethernet/IP Communication Interface Packaging including: - CI873, Communication Interface - TP867, Baseplate width = 60 mm Can only be used with LD 800DN. LD 800DN EtherNet/IP to DeviceNet Linking Device Package including: 1 pcs LD 800 DN 1 pcs Installation Guide 2 pcs Termination resistors for DeviceNet, 1/4 W, 121 Ohm Can only be used with CI873 Communication Interface. 3BSC690164R1 3BSE056899R1
Communication
Advant Fieldbus 100
Article no. CI869K01 AF 100 Communication Interface Package including: - CI869 , Communication Interface - TP869 , Baseplate, width = 60 mm 3BSE049110R1
FOUNDATION Fieldbus The required FOUNDATION Fieldbus network components (Linking Devices, etc) must be ordered from price list 3BDD 013 231, FOUNDATION Fieldbus Network Components.
Article no. CI860K01 FOUNDATION Fieldbus HSE Interface Package including: - CI860, Communication Interface - TP860, Baseplate, width = 60 mm 3BSE032444R1
IEC 61850
For order of IEC 61850 related products, local organizations must comply with the Demands on the Purchaser to secure successful sales of IEC 61850 with System 800xA. Ref doc, 3BSE058798. Article no. CI868K01 IEC61850 Communication interface Package including: - CI868 , Communication Interface - TP867 , Baseplate, width = 60 mm At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 3BSE048845R1
MasterBus 300
Article no. CI855K01 MB 300 Dual Ethernet port interface Package including: - CI855, MB300 Interface Module - TP853, Base plate 3BSE018106R1
Article no. CI856K01 S100 I/O interface Installed on DIN rail. Communication bridge between AC 800M and S100 system. Package including: - CI856, Communication Interface - TP856, Baseplate, width = 60 mm 3BSE026055R1
Communication
TRIO
Article no. CI862K01 TRIO Interface Kit Package including: - CI862, Communication Interface - TP862, Baseplate, width = 60 mm CI862K02 Redundant TRIO Interface Kit with Connection Cable Package including: - 2 x CI862, Communication Interface - 2 x TP862, Baseplate, width = 60 mm - TK862 Cable, 1 m 3BUA000111R1 3BUA000037R1
Satt I/O For SATT 19" rack I/O and S200 I/O via ControlNet. For additional Satt 19" rack i/O components, see price list 3BSE014353 (Interface) in price book 3BSE014360 (SattLine/SattCon).
Article no. CI865K01Communication Interface Module for Satt I/O Package including: - CI865, Communication Interface - TP865, Baseplate, width = 60 mm 3BSE040795R1
INSUM
Article no. CI857K01 INSUM Ethernet interface Package including: - CI857, Communication Interface - TP853, Baseplate, width = 60 mm 3BSE018144R1
DriveBus
Article no. CI858K01 DriveBus Interface Package including: - CI858, Communication Interface - TP858, Baseplate, width = 60 mm 3BSE018135R1
Communication
Bus Accessories
Article no. TK850V007 CEX-Bus Extension Cable Length = 0.7 m. Use of TK850V007 needs TK851 as CEX-bus terminator. TB850 CEX-Bus Terminator With 25-pin DB25P male connector. With screw fixing. A TB850 CEX-Bus terminator must always be installed on the last unit on the CEX-bus. TB851 CEX-Bus Terminator With 25-pin DB25S female connector. With screw fixing. When Communication Interface units are mounted on adjacent DIN rails, they are connected by means of a CEX-Bus extension cable (TK850) and terminated using a TB851 CEX-Bus terminator. BC810K02 CEX-Bus Interconnection Unit Including: - BC810, Interconnection Unit, 2 units - TP857, Baseplate, width = 60 mm, 2 units - TK851, Interconnection Cable - TB850, CEX-Bus Terminator, 2 units TK851V010 Connection Cable Length = 1.0 m Used as: - RCU Link Cable - BC810 Interconnection Cable TB852 RCU Link Terminator TB853 RCU Control Link Terminator for PM891 TK855 RCU Data Link Cable for PM891 Length = 1.0 m Used as: RCU Data Link Cable TK856 RCU Control Link Cable for PM891 Length = 1.0 m Used as: RCU Control Link Cable 3BSE057021R1 3BSC950263R1 3BSE057022R1 3BSC950356R1 3BSC950262R1 3BSE031155R1 3BSC950194R1 3BSC950193R1 3BSC950192R1
Tool Accessories
Article no. TK212A Tool cable RJ45 (male) to Dsub-9 (female), length 3 m. RJ45 8P8C plug (with shell). Cable : UL2464 26 AWG x 8C. TC562 Short Distance Modem length < 10 km. Point-to-point up to 1 km at 19200 bps. Power 24 V d.c. Width = 55 mm. TK853V020 Modem Cable Length 2 m. Cable for connection between modem TC562 and TP830. 3BSC950201R1 3BSC630049R1 3BSC630197R1
Network components
PROFIBUS Network Components
Article no. RLM01 PROFIBUS Redundancy Link Module for PROFIBUS line redundancy Converts a non-redundant PROFIBUS line to two redundant RS485 lines or vice versa. Germanischer Lloyd (GL) certified (cat. A,B,C,D) in connection with power supply filter (3BDZ000397R1). Power Supply Filter (surge) 24 V DC Mandatory to fulfill the requirements of Germanischer Lloyd (GL). PROFIBUS DP/PA Linking Devices (classic) ABB recommends for new plants to use the Pepperl + Fuchs PROFIBUS Power Hub. All required components of the PROFIBUS Power Hub System are covered by a Global Supply Agreement between ABB and Pepperl+Fuchs; for details refer to document 2PAA103809. How to use the Power Hub, especially the configuration settings when used within ABB control systems, is described in the Application Guide 2PAA102122R0201, Integration of PROFIBUS PA with Pepperl+Fuchs PROFIBUS Power Hub. PCO 010 PROFIBUS DP connector, standard Max. 12 Mbit/s, 35 cable outlet, IP40, without bus termination. PCO 011 PROFIBUS DP connector with bus termination Max. 12 Mbit/s, 35 cable outlet, IP40, switchable bus termination. PCO 012 PROFIBUS DP connector with bus termination and adapter Max. 12 Mbit/s, 35 cable outlet, IP40, switchable bus termination, programming connection SUB-D. 3BDZ000372R1 3BDZ000371R1 3BDZ000370R1 3BDZ000397R1 3BDZ000398R1
Article no. LD 800HSE Linking Device LD 800 HSE module for DIN rail mounting with 4 H1 links and one HSE connector. The module itself needs external 24 V DC power supply. H1 links must be powered separately. Redundancy Link Cable, 0.5 m Redundancy Link Cable links two LD 800HSE to a redundant set of devices. 3BDH000281R1 3BDH000320R02
Power Supply
Power Supply
Article no. SD822Z Power Supply Device, G3 Compliant Input 115/230 V a.c. switch selectable, output 24 V d.c., 5 A. If redundant power application is required connect to SS822Z Voting Unit. Width = 65 mm. DIN rail mounted. SD831 Power Supply Device Input a.c. 100-240 V or d.c. 110-300 V. Output d.c. 24 V, 3 A. If redundant power application is required connect to SS8XX. Voting unit. Width = 35 mm. DIN rail mounted. SD832 Power Supply Device Input a.c. 100-120/200-240 V. Output d.c. 24 V 5 A, auto-select input. If redundant power application is required connect to SD8XX. Voting unit. Width = 35 mm. DIN rail mounted. SD833 Power Supply Device Input a.c. 100-120/200-240 V, auto-select input. Output d.c. 24V 10 A. If redundant power application is required connect to SD8XX. Voting unit. Width = 60 mm. DIN rail mounted. SD834 Power Supply Device Input a.c. 100-240 V or d.c. 110-300 V. Output d.c. 24 V 20 A. If redundant power application is required connect to SS8XX. Voting unit. Width = 85 mm. DIN rail mounted. SS822Z Power Voting Unit , G3 Compliant With dual 24 V d.c 20 A inputs, single 24 V d.c. 20 A output. Each power input supervised. Used if redundant power supply is required. For use with power supply SD822Z. Width = 50 mm. DIN rail mounted. SS832 Voting Device Input d.c. 24 V. Dual 24 V to single 24 V, 2 x 10 A. Width = 35 mm. DIN rail mounted. Mains Breaker Kit for DIN Rail 115/230 V a.c. with input terminals, breaker and 3 fused (6.3 A), double output terminals, width = 102,5 mm. 3BSE022262R1 3BSC610068R1 3BSC610055R1 3BSC610067R1 3BSC610066R1 3BSC610065R1 3BSC610064R1 3BSC610054R1
Mounting Rails
Mounting Rails
Article no. Al-profile with DIN rail and Cable Duct for RE820, mounting 719 mm (28,3). DIN rail length 683 mm (26,9). Al-profile with DIN Rail and Cable Duct for RM550, mounting 592 mm (24). DIN rail length 556 mm (21,9). Al-profile with DIN Rail and Cable Duct, mounting 465 mm (19). DIN rail length 429 mm (16,9). 3BSE022255R1 3BSE022256R1 3BSE022257R1
S800
S800L
Digital input modules DI810 DI811 DI814 DI820 DI821 DI825 DI830 DI831 DI885 DP820 DP840 DO810 DO814 DO815 DO820 DO821 AI810 AI815 AI820 AI825 AI830A AI835A AO810V2 AO815 AO820 16 channels, 2 groups of 8 channels,, 24 V d.c., current sink. 16 channels, 2 groups of 8 channels,, 48 V d.c., current sink. 16 channels, 2 groups of 8 channels,, 24 V d.c., current source. 8 channels, separate returns, 110 V d.c., 120 V a.c. 8 channels, separate returns, 220 V d.c., 230 V a.c. With time tagging, 8 channels, separate returns, 125 V d.c. With time tagging. 16 channels, 2 groups of 8 channels, 24 V d.c., current sink. Resolution: < 0.5 ms. With time tagging. 16 channels, 2 groups of 8 channels, 48 V d.c., current sink. Resolution: < 0.5 ms. With time tagging & wire-fault detection. 8 channels, common return, 24-48 V d.c., current sink. Resolution: 1 ms. 2 channels, separate returns, 0.25 Hz - 1.5 MHz, signal voltage: 5 / 12 V d.c. 8 channels, extended diagnostics, wire-fault detection, current limited sensor supply, 0.5-20 kHz, 12/24 V d.c or NAMUR, common return. 16 channels, 2 groups of 8 channels,, 24 V, max 0.5 A d.c., transistor, current source, short-circuit-proof. 16 channels, 2 groups of 8 channels,, 24 V d.c., max 0.5 A, transistor, current sink, short-circuit-proof. 8 channels, 2 groups of 4 channels,, 24 V d.c., max 2 A, transistor, current source, short-circuit-proof, wire-fault detection. 8 channels, separate returns, 5-250 V, max 3 A a.c./d.c., relay (N.O.). 8 channels, separate returns, 5-250 V, max 3 A a.c./d.c., relay (N.C.). 8 channels, single-ended, 0(4)-20 mA, 0(2)-10 V, 12 bits. 8 channels with HART. 0(4)..20 mA, 0(1)..5 V, 12 bit, single ended, current limited transmitter supply. Differential inputs, 4 channels, 0(1)-5 V, 0(2)-10 V, 0(4)-20 mA, 14 bits + sign. Individually galvanically isolated channels, 4 channels, 0(2)-10 V, 0(4)- 20 mA, 14 bits + sign. RTD inputs, 8 channels, Pt100, Ni100, Ni120, Cu10, resistor 0-400 ohms, 14 bits, 3-wire. TC inputs, 8 channels, (7+ ref. junction), separate returns. TC types B, C, D, E, J, K, L, N, R, S, T, U, - 3075 mV, 15 bits. 8 channels, common return, 0(4)-20 mA, 14 bits, load: 850 ohms (short-circuit-proof). 8 channels with HART. 4..20 mA, 12 bit, load: 750 ohms, common return, short-circuit-proof. 4 channels, individually galvanically isolated, separate returns, measuring range: 0(2)-10 V, 0(4)-20 mA, resolution: 12 bits + sign, load: 500 ohms (current) / 5 kohms (voltage), short-circuit-proof. Intrinsic-safety modules DI890 DO890 AI890 AI893 AI895 AO890 AO895 DI840 DP840 DO840 AI843 AI845 AO845 AI880A DI880 DO880 SS823 8 channels, separate returns, proximity sensors (NAMUR) or voltage-free contact., current sink, wire-fault detection. 4 channels, separate returns, load 150-5000 ohms, 11 V @ 40 mA, current source, wire-fault detection, short circuit-proof. 8 channels, single-ended, 0(4)-20 mA, 12 bits, transmitter power supply. 8 channels, TC: 7 + ref. junction, sep. returns. TC types B, C, E, J, K, L, N, R, S, T, U, -1080 mV. RTD: Pt50-1000, Ni100-500, Cu 10-100, resistor 0-4000 W, 3-wire. 15 bits + sign. 8 channels, single-ended, 4-20 mA, 12 bits, transmitter power supply, HART pass-through. 8 channels, common return, 0(4)-20 mA, 12 bits, load: 725 ohms short-circuit-proof. 8 channels, common return, 4-20 mA, 12 bits, load: 725 ohms short-circuit-proof, HART pass-through. 16 channels, common return, 24 V d.c., current sink, extended diagnostics, time-tagging, current limited sensor supply. 8 channels, common return, 0.5-20 kHz, 12/24 V d.c or NAMUR, extended diagnostics, wire-fault detection. 16 channels, common return, 24 V d.c., max. 0,5 A, transistor, current source, short-circuit-proof, extended diagnostics. TC input, 8 channels + ref. junction. TC types: B, C, E, J, K, L, N, R, S, T, U, -3075 mV, 16 bits, extended diagnostics. 8 channels, 12 bits, 0(4)-20 mA 0(1)-5 V, extended diagnostics, HART pass-through, current limited transmitter supply, single ended. 8 channels, 12 bits, common return, 4-20 mA, extended diagnostics, HART pass-through, 750 ohms. 4..20 mA, 8 channels, 12 bits, SIL3, current limited transmitter supply, also 0-20 mA, single ended, extended diagnostics, HART communication. 24 V d.c., 16 channels, 24 V d.c. inputs, SIL3, time-tagging, current limited sensor supply, common return, current sink, extended diagnostics. 24 V d.c., 16 channels, 0,5 A outputs, SIL3, wire-fault detection, 24 V, transistor, current source short-circuit-proof, common return, extended diagnostics. Required in a High Integrity 800xA system. One per power supply unit, also at redundant configurations.
Redundant modules
S800L modules DI801 DI802 DI803 DO801 DO802 AI801 AO801 16 channels, 1 group, 24 V d.c., current sink. 8 channels, 110 V d.c., 150 V a.c. 8 channels, 220 V d.c., 230 V a.c. 16 channels, common return, 24 V, max 0.5 A d.c., transistor, current source, short-circuit-proof. 8 channels, 5-250 V, max 2 A a.c./d.c., relay (N.O.). 8 channels, single-ended, 0(4)-20 mA, 12 bits. 8 channels, common return, 0(4)-20 mA, 12 bits, load: less than 750 ohms.
Environmental Data for AC 800M and S800 I/O Climatic Operating Conditions Protection class Corrosive protection Electromagnetic Compatibility and CE-mark Electromagnetic Emission Electromagnetic Immunity Electrical Safety Hazardous Classified Locations Hazardous Classified Locations ATEX Safety Integrity (IEC 61508) 0 to +55 C (Storage -40 to +70C), RH=5 to 95 % no condensation, IEC/EN 61131-2 IP20 according to EN 60529, IEC 529 G2 compliant according to ISA-71.04 (G3 compliant according to ISA-71.04 available on request) Meets EMC directive 2004/108/EC according to EN 61000-6-2 and EN 61000-6-4 Tested according to EN 61000-6-4 EMC Generic Emission Standard, Part 2 Industrial Environment Tested according to EN 61000-6-2 EMC Generic Immunity Standard, Part 2 Industrial Environment UL508, IEC/EN 61131-2 UL/CSA 60079-15 (Class 1 Zone 2) S890 series of I/O modules: Category 3 (1) G, EEx nA [ia] IIC T4 PM865, AI880A, DI880, DO880: IEC 61508 up to SIL3
Measurements
CI810
84 (3.3) 162 (6.4) 127.5 (5.0)
CI820, TB815
58 (2.3) 162 (6.4) 127.5 (5.0)
Compact I/O
58 (2.3) 162 (6.4) 132 (5.2)
Redundant I/O
123 (4.8) 162 (6.4) 132 (5.2)
Extended I/O
120 (4.7) 110 (4.3) 132 (5.2)
Dimensions in mm (in.)
136 (5.4)
194 (7,6)
Temperature RTD
Temperature T/C
Analog Unipolar
Analog Bipolar
Intrinsic safety
Digital input modules DI810 DI811 DI814 DI820 DI821 DI825 DI830 DI831 DI840 DI880 DI885 DI890 Digital output modules DO810 DO814 DO815 DO820 DO821 DO840 DO880 DO890 Pulse input modules DP820 DP840 Analog input modules AI810 AI815 AI820 AI825 AI830A AI835A AI843 AI845 AI880A AI890 AI893 AI895 Analog output modules AO810V2 AO815 AO820 AO845 AO890 AO895 S800L modules DI801 DI802 DI803 DO801 DO802 AI801 AO801 v
High integrity
Binary Relay
Binary 110 V
Binary 230 V
Binary 24 V
Binary 48 V
Redundant
HART
SOE
Communication
Field Communication Interface
Article no. CI801 PROFIBUS DP-V1 Communication Interface Including: 1 pcs Power Supply Connector. 1 pcs TB807 Modulebus Terminator. The basic system software loaded in CI801 does not support the following I/O modules: DI830, DI831, DI885, AI880A, DI880 and DO880. CI801 Engineering kit SW1.3 Including: 1 pcs CD with GSD file, Memory Maps and Release Note. 1 pcs Reference Manual Memory Maps for CI801. CI810B AF100 Field Comm. Interface 2*AF100 Twisted Pair Connections. Including: 1 pce Power Supply Connector. 1 pce TB807 Modulebus Terminator The basic system software loaded. CI820V1 S800 Redundant FCI 1*AF100 Modem, 0.5 FPROM, 0.5MB SRAM, 16MHz Two CI820 must be ordered for redundancy. One item A070 must also be ordered with this item. The basic system software is loaded. CI840A PROFIBUS DP-V1 Communication Interface. For 1+1 redundant operation. Two CI840A and one TU847 or one TU846 must be ordered. The basic system software loaded in CI840A does not support the following I/O modules: DI830, DI831, DI885, AI880A, DI880, DO880 and ABB Drives. CI840A Engineering kit SW 4.0 Including: 1 pcs CD with GSD file, Memory Maps and Release Notes. 1 pcs Reference Manual Memory Maps for CI840A. TB815 Interconnection Unit Including: 1 pce TB807 Modulebus Terminator. Used for interconnection of two CI820. TU846 Module Termination Unit, MTU, for 1+1 CI840. Support for redundant I/O. Vertical mounting of modules. Including: 1 pce Power Supply Connector. 2 pcs TB807 Modulebus Terminator TU847 Module Termination Unit for 1+1 CI840. Support for non-redundant I/O. Vertical mounting of modules. Including: 1 pce Power Supply Connector. 1 pce TB807 Modulebus Terminator. Extra, Front label set FCI/AC 70/TB. Sheet with 12 labels. For CI810, CI820, CI830, and TB820. Extra, Label set, item design. FCI/AC70/TB. Sheet with 40 labels. For CI810, CI820, CI830, and TB820. Mounting kit For vertical mounting of CI801, CI840, and TB840 on a vertical DIN rail. Mounting profile 1800, 2 DIN rails and 1 cable duct. DIN rail length : 1650 mm + 210 mm (65) + (8.3). Al-profile with DIN Rail and Cable Duct, mounting 465 mm (19). DIN rail length 429 mm (16,9). Al-profile with DIN Rail and Cable Duct for RM550, mounting 592 mm (24). DIN rail length 556 mm (21,9). 3BSE022256R1 3BSE022255R1 3BSE049768R1 3BSE040749R1 3BSC970091R1 3BSC970089R1 3BSE022462R1 3BSE022460R1 3BSE013204R1 3BSE031694R4000 3BSE041882R1 3BSE025255R1 3BSE020520R1 3BSE038540R1300 3BSE022366R1
Communication
Upgrade Kit and Tool Cables Upgrading of CI801, CI810, CI820, CI830, CI840 or CI840A to latest software version are available for download from ABB Library/Solutions Bank. Item A190 is cable connecting a PC to CI810, CI820 and CI830 for download of software. Item A195 is cable connecting a PC to CI840 or CI840A for download of software. CI801 requires items A195 and A197 for download of software
Article no. TK527V030 Interface cable L = 3 m. DE9 pin to DE9 socket. For connection of CI810, CI820 and CI830 to PC. TK212A Tool cable RJ45 (male) to Dsub-9 (female), length 3 m. RJ45 8P8C plug (with shell). Cable : UL2464 26 AWG x 8C. FS801K01 Service adapter kit Including: 1 pcs Service adapter FS801 1 pcs cable TK802 For connection of CI801 to PC. A cable TK212A is also needed. 3BSE038407R1 3BSC630197R1 3BSC950004R1
Article no. TB805 Bus Outlet Modulebus extension cable adaptor D-sub 25, female. One requried per extension cable TK801. TB845, Dual Modulebus outlet Modulebus extension cable adaptor two D-sub, female. Two TK801 cables for redundancy. TB806 Bus Inlet Modulebus extension cable adaptor D-sub 25, male. One requried per extension cable TK801. TB846, Dual Modulebus inlet Modulebus extension cable adaptor two D-sub, male. Two TK801 cables for redundancy. TK801V003 Cable Modulebus Extension Shielded Cable 0.3 m D-sub 25, male-female. TK801V006 Cable Modulebus Extension Shielded Cable 0.6 m D-sub 25, male-female. TK801V012 Cable Modulebus Extension Shielded Cable 1.2 m D-sub 25, male-female. 3BSC950089R3 3BSC950089R2 3BSC950089R1 3BSE021439R1 3BSE008536R1 3BSE021437R1 3BSE008534R1
Article no. TB807 Modulebus terminator TB820V2 Modulebus Cluster Modem Optical cluster modem for non redundant operation. Including: 1 pce Power Supply Connector 1 pce TB807 Modulebus Terminator. TB825 Optical Media Conv. Short to long distance optical fiber conversion. For modulebus communication up to 1000 m. TB840A Modulebus Cluster Modem Optical cluster modem for 1 + 1 redundant operation. TB810 Modulebus Optical Port Used together with CI810, CI820, CI830 Use with S800 I/O and ABB Drives (10 Mbits driver) TB811 Modulebus Optical Port Used together with CI810, CI820, CI830 Used with ABB Drives equipment. (5 Mbits driver) TB842 Modulebus Optical Port Used together with CI801 and CI840, connected via TB806 or TB846. (10 Mbits driver) TU807 Termination Unit for TB840/TB840A Support for single modulebus I/O. Including: 1 pcs TB807. TU840 Termination Unit for redundant TB840A. Support for redundant I/O Including: 1 pcs Power Supply Connector 2 pcs TB807 Modulebus Terminator TU841 Termination Unit for redundant TB840A. Support for non-redundant I/O Including: 1 pcs Power Supply Connector 1 pcs TB807 Modulebus Terminator TU848, MTU with individual power supply for red. TB840/ TB840A. Support for dual modulebus. Including: 2 pcs TB807 TU849, MTU with individual power supply for red. TB840/ TB840A. Support for single modulebus. Including: 1 pcs TB807 TK811V015 POF Cable, 1.5 m, Duplex. L = 1.5 m latching duplex connector Duplex plastic fibre. TK811V050 POF Cable, 5 m, Duplex. L = 5 m latching duplex connector Duplex plastic fibre. TK811V150 POF Cable, 15 m, Duplex. L = 15 m latching duplex connector Duplex plastic fibre. TK812V015 POF Cable, 1.5 m, Simplex. L = 1.5 m latching connector Simplex plastic fibre. TK812V050 POF Cable, 5 m, Simplex. L = 5.0 m latching connector Simplex plastic fibre. TK812V150 POF Cable, 15 m, Simplex. L = 15 m latching connector Simplex plastic fibre. 3BSC950118R3 3BSC950118R2 3BSC950118R1 3BSC950107R3 3BSC950107R2 3BSC950107R1 3BSE042560R1 3BSE042558R1 3BSE020848R1 3BSE020846R1 3BSE039025R1 3BSE022464R1 3BSE008568R1 3BSE008560R1 3BSE037760R1 3BSE036634R1 3BSE008538R1 3BSE013208R1
Article no. AI810 Analog input 1 x 8 ch. 0(4)..20 mA, 0..10 V, 12 Bit, single ended, 0.1%, Rated isol. 50V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU835, TU838, TU850. AI815 Analog Input 1 x 8 ch. with HART 0(4)..20 mA, 0(1)..5 V, 12 bit, single ended, 0.1%, Rated isol. 50V. Current limited transmitter power distribution. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU835, TU838, TU850. AI820 Analog input 4 x 1 ch. +/-20 mA, 0(4)...20 mA, +/-10 V, +/-5 V, 0(1)...5 V, diff., 50 V CMV, 14 bit +sign. Rin(curr)250 Ohms, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. AI825 Analog Input 4 x 1 ch. Galv. isol. -20..20 mA, 0(4)..20 mA, -10..10 V, 0(2)..10 V, Galvanically isolated channels. 14 Bit+sign, 0.1%, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831. AI830A Analog input 1 x 8 ch. RTD Pt100, Ni100/120, Cu 10, R, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. AI835A Analog input 8 ch. Thermocouple/mV Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. AI843 Analog Input, Redundant or Single 1 x 8 ch. Termocouple/mV. Rated isol. 50 V. Use Modules Termination Unit TU830, TU833, TU842, TU843. AI845 Analog Input, Redundant or single 1 x 8 ch. HART. 0(4)..20 mA, 0(1)..5 V, 12 bit, single ended, 0.1%, Rated isol. 50V. Current limited transmitter power distribution. Advanced on-board diagnostics. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU835, TU838, TU844, TU845. AI890 Analog Input 1 x 8 ch. with Intrinsic Safety Interface 0(4)...20 mA single ended 0,1%. Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. AI893 Analog Input 8 ch. Temp. measuring. Intrinsic Safety Interf. For TC and RTD sensors. Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. AI895 Analog Input 1 x 8 ch. with Intrinsic Safety and HART. 4...20 mA single ended 0,1%. Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. 3BSC690086R1 3BSC690141R1 3BSC690071R1 3BSE023675R1 3BSE028925R1 3BSE051306R1 3BSE040662R1 3BSE036456R1 3BSE008544R1 3BSE052604R1 3BSE008516R1
Article no. AO810V2 Analog Output 1 x 8 channels, 0(4)...20 mA 0(4)..20 mA, 14 bit RLmax 500/850 Ohms, Rated isolation 50V. Use module Termination Unit TU810, TU812, TU814, TU830 or TU833. AO815 Analog Output 1 x 8 ch. with HART 4..20 mA, 12 bit, 0.1%, RLmax 750 ohm, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830 or TU833. AO820 Analog Output 4 x 1 ch. +/-20 mA, 0(4)...20 mA, +/-10 V, 12 bit + sign. Indiv. isol. ch. RL max 500 Ohms, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. AO845A Analog Output Redundant or single 1 x 8 ch. HART 4..20 mA, 12 bit, 0.1%, RLmax 750 ohm, Rated isol. 50 V. Advanced on-board diagnostics. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU842, TU843. AO890 Analog Output 1 x 8 ch. with Intrinsic Safety Interface 0(4)...20 mA 0,1%. RL max 750 ohm Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. AO895 Analog Output 1 x 8 ch. with Intrinsic Safety and HART. 4...20 mA 0,1%. RL max 750 ohm Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. 3BSC690087R1 3BSC690072R1 3BSE045584R1 3BSE008546R1 3BSE052605R1 3BSE038415R1
Article no. DI810 Digital Input 24 V d.c. 2 x 8 ch. Rated isolation 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DI811 2 x 8 ch. 48 V Digital input 48 Vd.c. 2 x 8 ch, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DI814 Digital Input 24 V d.c. Current Source 2 x 8 ch. Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DI820 Digital Input, 120 V a.c. 8 x 1 ch, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831. DI821 Digital Input 230 V a.c. 8 x 1 ch, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831. DI825 Digital Input 1 x 8 ch, 125 V d.c. SOE. Individually Isolated channels, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831. DI830 Digital Input 24 V d.c. SOE 2 x 8 ch, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DI831 Digital Input 48 V d.c., SOE. 2 x 8 ch, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DI840 Digital Input. Redundant or single, 24 V d.c., 1 x 16 ch. Advanced On-Board diagnostics. Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838, TU842, TU843. DI885 Digital Input 24/48 V d.c., SOE. 1 x 8 ch, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. DI890 Digital Input 8 x 1 ch. with Intrinsic Safety Interface Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. 3BSC690073R1 3BSE013088R1 3BSE020836R1 3BSE013212R1 3BSE013210R1 3BSE036373R1 3BSE008550R1 3BSE008512R1 3BUR001454R1 3BSE008552R1 3BSE008508R1
Article no. DO810 Digital Output 24 V d.c. 2 x 8 ch. 0.5 A, Short circuit proof, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. DO814 Digital Output current sinking 2 x 8 ch. 0,5 A, shortcut circuit proof, Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU838. DO815 Digital Output 24 V d.c 2 x 4 ch. 2.0 A, short circuit proof. Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. DO820 Digital Output, Relay. Normal open. 8 x 1 ch, 24-230 V a.c. 3 A, cos phi > 0.4, d.c. 42 W, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831, TU836, TU837. DO821 Digital Output, Relay. Normal closed. 8 x 1 ch, 24-230 V a.c. 3 A, cos phi > 0.4, d.c. 42 W, Rated isol. 250 V. Use Module Termination Unit TU811, TU813, TU831, TU836, TU837. DO840 Digital Output. Redundant or single. 24 V d.c., 0.5 A. 2 x 8 ch. Advanced On-board diagnostics. Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU842, TU843. DO890 Digital Output 4 x 1 ch. with Intrinsic Safety Interface Rated isol. 50 V. Use Module Termination Unit TU890 or TU891. 3BSC690074R1 3BSE020838R1 3BSE013250R1 3BSE008514R1 3BSE013258R1 3BUR001455R1 3BSE008510R1
Article no. DP820 Pulse Counter RS-422, Current, 5 V, (12 V), 24 V. 2 ch. bidirectional pulse counters and frequency measurement. 1,5 MHz Rated isol 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833. DP840 Pulse Counter or Frequency Measurement Module. Redundant or single. 1 x 8 ch, 20 kHz. Rated isol. 50 V. Use Module Termination Unit TU810, TU812, TU814, TU830, TU833, TU842, TU843, TU844, TU845. 3BSE028926R1 3BSE013228R1
Article no. Extra, Front label set I/O-box 16 ch. Sheet with 12 labels for 16 channels I/O modules. Extra, Front label set I/O-box 8 ch. Sheet with 12 labels for 8 channels I/O modules. Label set, I/O-box 4 ch. Sheet with 12 labels for 4 channel I/O modules. 3BSC970306R1 3BSC970088R1 3BSC970087R1
High Integrity I/O Modules The modules can only be connected to AC 800M controller PM865. Direct connection to the modulebus and via the optical modulebus via TB840 (not TB820).
Article no. AI880A High Integrity Analog Input. Single or Redundant. HART. 4..20 mA, 8 ch. Current input. HART communication. Certified for SIL3. Requires configuration according to Safety Manual. DI880 High Integrity Digital Input. Single or Redundant. 24 V d.c., 16 ch. 24 V d.c. inputs. Certified for SIL3. Requires configuration according to Safety Manual. DO880 High Integrity Digital Output. Single or Redundant. 24 V d.c., 16 ch. 0,5 A Outputs. Certified for SIL3. Requires configuration according to Safety Manual. SS823 Voting Device Required in a High Integrity 800xA system. One per power supply unit, also at redundant configurations. 3BSE038226R1 3BSE028602R1 3BSE028586R1 3BSE039293R1
Article no. TU805K01 Termination Units for two or three wire connection of DI801 and DO801 Include 10 pcs of Termination Unit TU805. TU810V1 Compact Module Termination Unit, MTU, 50 V. 2 x 8 signal terminals, rated isol. 50 V. TU811V1 Compact Module Termination Unit, MTU, 250 V. 1 x 8 signal terminals, rated isol. 250 V. TU812V1 Compact Module Termination Unit, MTU, 50 V. With 25 pin D-sub connector, rated isol. 50 V. D-sub (female) connector is not enclosed. TU813 Compact Module Termination Unit, MTU, 250 V. 2 x 8 Signal terminals, Rated isol. 250 V. Detachable (pluggable) connectors are enclosed. TU814V1 Compact Module Termination Unit, MTU, 50 V. 2 x 8 Signal terminals, rated isol. 50 V. Detachable (pluggable) connectors are enclosed. TU830V1 Extended Module Termination Unit, MTU, 50 V. 2 x 16 signal terminals, rated isol. 50 V. TU831V1 Extended Module Termination Unit, MTU, 250 V. 2 x 8 signal terminals, rated isol. 250 V. TU833 Extended Module Termination Unit, MTU, 50 V. 2 x 16 signal terminals, Rated isol. 50 V. Spring-cage terminals. TU834 Extended Module Termination Unit, MTU 50 V. Used with AI880/AI880A. Rated isol. 50 V. Shunt Stick not included. TU835V1 Extended Module Termination Unit, MTU, 50 V. 8 fused power outlets, 8 signal terminals, rated isol. 50 V. TU836V1 Extended Module Termination Unit, MTU, 250 V. 2 x 4 fused signals, 2 x 4 return terminals, 2 x 2 L 2 x 2 N terminals, rated isol. 250 V. TU837V1 Extended Module Termination Unit, MTU, 250 V. 8 x 1 fused isol. signals, 8 x 1 L terminals, 2 x 6 N terminals, rated isol. 250 V. TU838 Extended Module Termination Unit, MTU, 50 V. 2 x 4 fused transducer power outlets, 16 signal terminals, 2x4 return terminals, 2 x 2 L+, 2 x 2 L- terminals, rated isol. 50 V. Module is mounted horizontally. TU839 Extended Module Termination Unit, 250 V. 2 x 8 signal terminals. 2 x 4 fused sensor power. Rated isol. 250V. TU842 Module Termination Unit, MTU, for redundant applications, 50 V. Used for AO845, DI840, DO840. Horizontal mounted DIN rail. Rated isol. 50 V. TU843 Module Termination Unit, MTU, for redundant applications, 50 V. Used for AO845, DI840, DO840. Vertical mounted DIN rail. Rated isol. 50 V. 3BSE021443R1 3BSE020850R1 3BSE046966R1 3BSE008572R1 3BSE013238R1 3BSE013237R1 3BSE013236R1 3BSE040364R1 3BSE038726R1 3BSE013235R1 3BSE013234R1 3BSE013233R1 3BSE036714R1 3BSE013232R1 3BSE013231R1 3BSE013230R1 3BSE035990R1
Article no. TU844 Module Termination Unit, MTU, for redundant applications, 50 V. Used with AI845, AI880 and DP840. Horizontal mounted DIN rail. Rated isol. 50 V. Shunt Stick not included. TU845 Module Termination Unit, MTU, for redundant applications, 50 V. Used with AI845, AI880A and DP840. Vertical mounted DIN rail. Rated isol. 50 V. Shunt Stick not included. TU850 Extended Module Termination Unit, MTU, 50 V. 2 x 8 signal terminals and 2 x 8 disconnectable current limited sensor/transmitter outlet power terminals. Rated isol. 50 V. TU890 Module Termination Unit for Intrinsic Safety applications 3 x 9 signal terminals. Rated isol. 50 V. Including wiring separator. TU891Z Module Term. Unit f. non Intrinsic Safety applications 3 x 9 signal terminals Rated isol. 50 V. TY801K01 8 pcs Shunt Stick TY801 125 + 125 ohms shunt. Used for AI845 and AI880 on TU844, TU845. TY804K01 8 pcs Shunt Stick TY804 1000 ohms shunt. Used for DP840 on TU844, TU845. TY820K01 10 pcs Temperature Sensor TY 820 3BSE056980R1 3BSE033670R1 3BSE023607R1 3BSC840220R1 3BSC690075R1 3BSE050930R1 3BSE021447R1 3BSE021445R1
Article no. AI801 Analog input 1 x 8 ch. 0(4)..20 mA, 12 bit, single ended, 0.1%, Rated isol. 50 V. 3BSE020512R1
Article no. AO801 Analog output 1 x 8 ch. 0(4)...20 mA, 12 bit, RLmax 850 Ohm, Rated isol. 50 V. 3BSE020514R1
Article no. DI801 Digital Input 24 V d.c. 1 x 16 ch, Rated isol. 50 V. DI802 Digital Input 120 V a.c./d.c., 8 x 1 ch. Rated isol. 250 V. DI803 Digital Input 230 V a.c./d.c., 8 x 1 ch. Rated isol. 250 V. 3BSE022362R1 3BSE022360R1 3BSE020508R1
Article no. DO801 Digital Output 16 ch. 24 V d.c. 0.5 A. Short circuit proof, Rated isol. 50 V. DO802 Digital Output, Relay. Normal open. 8 x 1 ch, 24-230 V, a.c. Rated isol. 250 V. 3BSE022364R1 3BSE020510R1
Article no. Label Set S800L, 16 ch. Sheet with 12 labels for 16 channels I/O modules. Label Set S800L, 8 ch. Sheet with 12 labels for 8 channels I/O modules. 3BSE019419R2 3BSE019419R1
Series S series
Assembly In Zone 1
B series
In Zone 2
ATEX Zone 2
N series
In safe areas
In safe areas
No
S900
Termination Unit for up to 16 I/O modules Prepared for redundant system power and communication Up to 4 terminals per channel Preselection of fieldbus address Prepared for certified field housing Mounting in Zone 1 or Zone 2 possible
Name TU921S
Short Description Redundant Termination Unit (TU16R-Ex) For 16 I/O-modules. Redundant communication and power. (Delivery includes CD910).
TU921B
Redundant Termination Unit (TU16R-B) For 16 I/O-modules. Redundant communication and power. (Delivery includes CD910).
3KDE175112L9210
TU921N
Redundant Termination Unit (TU16R) For 16 I/O-modules. Redundant communication and power. (Delivery includes CD910).
3KDE175113L9210
Power supply
Power supply
Powering of communication interfaces and I/O modules Hot swap capability (SA920S in Zone 1, SA920B in Zone 2) Redundant powering Alarm in case of power failure (with redundancy) Switching On by tighten the 4 switch-on interlock screws (only SA920B and SA920S)
Short Description Power Supply For 24 V DC. The power supply filter type BP901S is not required. SA920S is the functional replacement for SA910S. Do not mix SA910S with SA920S for redundancy (observe Release Notes). Article No. 3BDH000602R1
Name SA920S
SA920B
Power Supply For 24 V DC. The power supply filter type BP901S is not required. SA920B is the functional replacement for SA910B Do not mix SA910B with SA920B for redundancy (observe Release Notes).
3BDH000601R1
SA920N
Power Supply For 24 V DC. The power supply filter type BP901S is not required. SA920N is the functional replacement for SA910N Do not mix SA910N with SA920N for redundancy (observe Release Notes).
3BDH000600R1
Communication interface
Communication interface
Fieldbus protocol PROFIBUS-DP V1 (EN 50170) Coupling of the internal CAN bus to external PROFIBUS HART protocol on PROFIBUS-DP V1 Line or media redundancy via two coupling modules Electrical isolation between field bus, power Diagnosis, configuration and parameterization via PROFIBUS
Short Description Communication Interface V.1.5.x (CIPB-Ex) Use only CI920S with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes) Article No. 3BDS014111
Name CI920S
CI920B
Communication Interface V.1.5.x (CIPB-B) Use only CI920B with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes).
3BDS014112
CI920N
Communication Interface V.1.5.x (CIPB) Use only CI920N with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes).
3BDS014113
Input for dry contacts or proximity switches (NAMUR) Output for low power intrinsically safe valves Short and break detection Electrical isolation between input / bus and input / power Common return for all inputs / outputs Configurable as a mixture of inputs and outputs 8 I/O channel, EEx ia II C
Name DX910S
Short Description Digital Input or Output (DIO8-Ex) Input for dry contact or NAMUR initiator. Output for low power Intrinsic Safe valves.
DX910B
Digital Input or Output (DIO8-B) Input for dry contact or NAMUR initiator. Output for low power I.S. valves.
3KDE175312L9100
DX910N
Digital Input or Output (DIO8) Input for dry contact or NAMUR initiator. Output for low power valves.
3KDE175313L9100
Solenoid driver
Solenoid driver
Output for intrinsically safe valves or alarms Integrated driving power Short and break detection Electrical isolation between output / bus and output / power Electrical isolation channel to channel 4 channels, EEx ia II C
Short Description Digital Output (DO4-Ex) Output for intrinsic safe valves. Article No. 3KDE175321L9100
Name DO910S
DO910B
3KDE175322L9100
DO910N
3KDE175323L9100
Relay output
Relay output
Relay output for higher switching power Output configurable as NO or NC contact Electrical isolation between output / bus and output / power Electrical isolation channel to channel Configurable as 4 x changeover contact Configurable as 6 x NO contact
Name DO930N
Short Description Relay Output (RO6) With 4 normally-open contacts and 2 changeover contacts (only to use with CI920N Article No 3BDS014113).
Frequency input
Frequency input
Frequency input for dry contacts or proximity switches Short and break detection Electrical isolation between input / bus and input / power Frequency measurement or counting applications 2 Function blocks Reset via fieldbus or control input Status outputs / Direction recognition
Name DP910S
Short Description Frequency Input (FI2-Ex) Input for dry contact or NAMUR initiator.
DP910B
3KDE175362L9100
DP910N
3KDE175363L9100
Analog input
Analog input
Power supply for 4...20 mA loop powered 2-wire transmitters Short and break detection Electrical isolation between input / bus and input / power Common return for all inputs 4 channels, EEx ia II C
Name AI910S
Short Description Analog Input (AI4-Ex) Transmitter power supply, 4..20 mA.
AI910B
3KDE175512L9100
AI910N
3KDE175513L9100
Analog input
Analog input, HART
Power supply for 4...20 mA loop powered 2-wire transmitters Short and break detection Electrical isolation between input / bus and input / power Common return for all inputs 4 channels, EEx ia II C Transmission of HART frames via the fieldbus
Name AI930S
Short Description Analog Input, HART (AI4H-Ex) Transmitter power supply, 4..20 mA.
AI930B
3KDE175512L9300
AI930N
3KDE175513L9300
Passive inputs for 0/4...20 mA Short and break detection Electrical isolation between input / bus and input / power Common return for all inputs 4 channels, EEx ia II C Transmission of HART frames via the fieldbus
Short Description Analog Input, HART (AI4H-Ex) Passive input, 0/4..20 mA. Article No. 3KDE175511L9310
Name AI931S
AI931B
3KDE175512L9310
AI931N
3KDE175513L9310
Temperature input
Temperature input
Pt 100, Pt 1000, Ni 100, 0...3 kOhm in 2-/3-/4-wire technique Thermocouple Type B, E, J, K, L, N, R, S, T , U , mV Internal or external cold junction compensation Short and break detection Electrical isolation between input / bus and input / power Electrical isolation channel to channel 4 channels, EEx ia II C
Short Description Temperature (TI4-Ex) Pt100, Pt1000, Ni100 in 2-/3-/4-technology thermocouples type B, E, J, K, L, N, R, S, T isolated inputs channel by channel. Article No. 3KDE175521L9500
Name AI950S
AI950B
Temperature (TI4-B) Pt100, Pt1000, Ni100 in 2-/3-/4-technology thermocouples type B, E, J, K, L, N, R, S, T isolated inputs channel by channel.
3KDE175522L9500
AI950N
Temperature (TI4) Pt100, Pt1000, Ni100 in 2-/3-/4-technology thermocouples type B, E, J, K, L, N, R, S, T isolated inputs channel by channel.
3KDE175523L9500
Analog output
Analog output
Output signal 0/4...20 mA for actuators Short and break detection Electrical isolation between output / bus and output / power Output with common ground 4 channels, EEx ia II C
Short Description Analog Output (AO4-Ex) Output 0/4...20 mA. Article No. 3KDE175531L9100
Name AO910S
AO910B
3KDE175532L9100
AO910N
3KDE175533L9100
Analog output
Analog output, isolated
Output signal 0/4...20 mA for actuators Short and break detection Electrical isolation between output / bus and output / power Electrical isolation channel to channel 4 channels, EEx ia II C
Short Description Analog Output, isolated (AO4I-Ex) Output 0/4...20 mA. Isolated outputs channel by channel. Article No. 3KDE175531L9200
Name AO920S
AO920B
Analog Output, isolated (AO4I-B) Output 0/4...20 mA. Isolated outputs channel by channel.
3KDE175532L9200
AO920N
Analog Output, isolated (AO4I) Output 0/4...20 mA. Isolated outputs channel by channel.
3KDE175533L9200
Output signal 0/4...20 mA for actuators Short and break detection Electrical isolation between output / bus and output / power Output with common ground 4 channels, EEx ia II C Transmission of HART frames via the fieldbus
Name AO930S
AO930B
3KDE175532L9300
AO930N
3KDE175533L9300
Field housing
Field housing Stainless steel field housing for extended Termination Unit Prepared for wall mounting Optional isolated shielding bar or terminals Mounting in Zone 1 or Zone 2
Short Description Empty field housing, without system certificate Article No. 3KDE175804L
FH660S - 0100
Field housing Including the following components: Termination Unit (backplane) TU921S 1 Power supply filter BP901S.
3KDE175804V0100
FH660S - 1100
Field housing Including the following components: Termination Unit (backplane) TU921S 2 Terminals (UK10N) 1 Power supply filter BP901S.
3KDE175804V1100
FH660S - 1110
Field housing Including the following components: Termination Unit (backplane) TU921S 2 Terminals (UK10N) 1 Power supply filter BP901S 1 Switch.
3KDE175804V1110
FH660S - 0200
Field housing Including the following components: Termination Unit (backplane) TU921S 2 Power supply filters BP901S.
3KDE175804V0200
FH660S - 2200
Field housing Including the following components: Termination Unit (backplane) TU921S 4 Terminals (UK10N) 2 Power supply filters BP901S.
3KDE175804V2200
FH660S - 2220
Field housing Including the following components: Termination Unit (backplane) TU921S 4 Terminals (UK10N) 2 Power supply filters BP901S 2 Switches.
3KDE175804V2220
600
275
300
635
600
600
Field housing
FH680S - 0100
Field housing Including the following components: Termination Unit (backplane) TU921S 1 Power supply filter BP901S.
3KDE175811V0100
FH680S - 0110
Field housing Including the following components: Termination Unit (backplane) TU921S 1 Power supply filter BP901S 1 Switch.
3KDE175811V0110
FH680S - 0200
Field housing Including the following components: Termination Unit (backplane) TU921S 2 Power supply filters BP901S.
3KDE175811V0200
FH680S - 0220
Field housing Including the following components: Termination Unit (backplane) TU921S 2 Power supply filters BP901S 2 Switches.
3KDE175811V0220
Accessories
Name S900 - BI100 Short Description Field Housing roof Weather protection. Fits to all field housing. Article No. 3KDE175831L1000
Compact box
Compact box
Name CB220S
Short Description Compact-Box For power supply SA911S, communication interface CI920S and four I/O modules S900 type S (Delivery includes CD910).
CB220B
Compact-Box For power supply SA911B, communication interface CI920B and four I/O modules S900 type B (Delivery includes CD910).
3KDE175612L2210
CB220N
Compact-Box For power supply SA911N, communication interface CI920N and four I/O modules S900 type N (Delivery includes CD910).
3KDE175613L2210
Powering of communication interfaces and I/O modules Hot swap capability (SA911S in Zone 1, SA911B in Zone 2)
Name SA911S Short Description Power supply for CB220S For 24 VDC. The power supply filter type BP901S is not required. SA911B Power supply for CB220B For 24 VDC. The power supply filter type BP 901S is not required. SA911N Power supply for CB220N For 24 VDC. The power supply filter type BP901S is not required. 3KDE175613L9110 3KDE175612L9110 Article No. 3KDE175611L9110
illustration similar
Ring-coupler
Name BI923S Short Description Ring-coupler RS485 / FO - intrinsically safe - Slave Separates an intrinsically safe fibre optic ring from a non intrinsically safe RS485 fieldbus. BARTEC - 07-7311-97WP5000 Mounted in DIN rail mounted housing with IP20 protection (Slave). BI924S Ring-coupler RS485 / FO intrinsically safe - Master Separates an intrinsically safe fibre optic ring from a non intrinsically safe RS485 fieldbus. BARTEC - 07-7311-97WP5200 Mounted in DIN rail mounted housing with IP20 protection (Master). BI933S Ring-coupler RS485 / FO Separates an intrinsically safe fibre optic ring from an intrinsically safe RS485 fieldbus. Mounted in separate field housing BARTEC - 07-3103-2512/177M (Slave). No longer deliverable. Use BI934S as replacement. For limited spare parts contact Orderbox Control Products DEAPR orderbox.control-products@de.abb.com. BI934S Ring-coupler RS485 / FO intrinsically safe Slave Separates an intrinsically safe fibre optic ring from one intrinsically safe RS485 fieldbus segment Mounted in separate field housing BARTEC - 07-3103-2512/371M Optical Plug FSMA Replacement for BI933S (Ready for order as from January 2010) 3BDH000674R0001 3KDE175831L9330 3KDE175831L9240 Article No. 3KDE175831L9230
Software
Name BI992 Short Description ABB DTM S900 DP - License in combination with ABB DCS systems only For parameterization and configuration of the S900 station according to FDT 1.2, for all PROFIBUS-addresses inclusive HART. (Observe Release Notes). CD910 Additional Software CD incl. S900 Documentation, Certificates, GSD (file) ABB DTM S900 DP. CD-ROM will be delivered with all TU921 and CB220 deliveries. 3KDE175839L9100 Article No. 3KDE175839L9920
Key panel
Touch panel
Panel 800
Specifications Panel 800 Display backlight CPU Memory, flash Memory, RAM Flash memory for application Real time clock Power supply Ambient temperature Relative humidity Housing material Front side material Peripherals Serial Ports Ethernet USB PROFIBUS Environmental Data for Panel 800 Climatic Operating Conditions
CCFL backlight with dimming and burn-out detection 316 or 416 MHz RISC CPU (Intel Xscale) 32 MB (Intel StrataFlash) 64 MB 12 MB YES +24 C14 20-30 V 0 to +50 C 5 - 85 % non-condensing Powder-coated aluminium Autotex F250 / F157 (keyboard), (PP865S in Stainless Steel 316 / 1.4401) RS422/RS485, female, 25-pin D-Sub, RS232C, male, 9-pin D-Sub Shielded RJ45 10/100 Mbit/sec Host type A (power consumption max. 500 mA), Device type B Expansion slot for PROFIBUS DP Vertical installation: 0 to +50 C Horizontal installation: 0 to +40 C Storage temperature -20 C to +70 C Relative humidity 5 - 85 % non-condensed Front panel seal IP 66 Rear panel seal IP 20 Meets EMC directive 2004/108/EC Tested according to EN61000-6-4 (2007) Tested according to EN61000-6-2 (2005) UL508 UL 1604 Class I, Div 2 Groups A, B, C, D, T4 ABS, DNV, GL, RINA
Protection class Electromagnetic Compatibility and CE-mark Electromagnetic Emission Electromagnetic Immunity Electrical Safety Hazardous Classified Locations* Marine Certificates*
* PP865S is not marine or UL certified
Specifications Display size Active area of display, W x H Resolution Interaction type LED Power consumption (normal/max) Dimensions Front panel, W x H x D Cut-out dimensions Mounting depth Weight
PP820 127,0 x 33,8 mm 240 x 64 pixels Function key 16 (2 color) 0,15 A 202 x 187 x 57 mm 166 x 149 mm 57 mm 0,875 kg
PP826 5,7" 320 x 240 pixels Function key 16 (2 color) 0,3 A 275 x 168 x 57 mm 240 x 130 mm 58 mm 1,11 kg
PP836 6,5" 640 x 480 pixels Function key 16 (2 color) 0,4 A / 0,9 A 285 x 177 x 60 mm 246 x 139 mm 55 mm 1,3 kg
PP846 10,4" 800 x 600 pixels Function key 20 (2 color) 0,5 A / 1 A 382 x 252 x 60 mm 343 x 208 mm 58 mm 2,3 kg
Specifications Display size Resolution Interaction type LED Power consumption (normal/max) Dimensions Front panel, W x H x D Cut-out dimensions Mounting depth Weight
PP815 3,8" 320 x 240 pixels Resistive Touch 0,15 A 156 x 119 x 59 mm 139 x 105 mm 57 mm 0,56 kg
PP825 5,7" 320 x 240 pixels Resistive Touch 0,25 A 201 x 152 x 57 mm 180 x 130 mm 57 mm 0,87 kg
PP 835 6,5" 640 x 480 pixels Resistive Touch 0,4 A / 0,9 A 219 x 154 x 60 mm 189 x 138 mm 55 mm 1,1 kg
PP845 10,4" 800 x 600 pixels Resistive Touch 0,5 A / 1 A 302 x 228 x 60 mm 265 x 206 mm 58 mm 2 kg
PP865 15" 1024 x 768 pixels Resistive Touch 1,2 A / 1,7 A 398 x 304 x 60 mm 356 x 279 mm 60 mm 3,7 kg
PP865S 15" 1024 x 768 pixels Resistive Touch 1,2 A / 1,7 A 398 x 304 x 60 mm 356 x 279 mm 60 mm 4,9 kg
Panel 800
Functional Key Panels Configuration of Panel 800 requires a Panel Builder 800.
Article no. Panel 800 - PP820 Key panel. 240 x 64 pixels, graphics & text, key, black/white. 3BSE042243R1
Panel 800 - PP826 5,7 Key panel. STN 320 x 240 pixels, graphics & text, color.
3BSE042244R1
Panel 800 - PP836 6.5 Function key panel. TFT 640 x 480 pixels, graphics & text, color.
3BSE042237R1
Panel 800 - PP846 10.4 Function key panel. TFT 800 x 600 pixels, graphics & text, color.
3BSE042238R1
Panel 800
Touch Panels
Article no. Panel 800 - PP815 3.8 Touch panel. TFT 320 x 240 pixels, graphics & text, touch, color. 3BSE042239R1
Panel 800 - PP825 5,7 Touch panel. STN 320 x 240 pixels, graphics & text, touch, color. To protect the touch screen, its recommended to use the RX825 Touch Cover.
3BSE042240R1
Panel 800 - PP835 6.5 Touch panel. TFT 640 x 480 pixels, graphics & text, touch, color. To protect the touch screen, its recommended to use the RX835 Touch Cover.
3BSE042234R1
Panel 800 - PP845 10.4 Touch panel. TFT 800 x 600 pixels, graphics & text, touch, color. To protect the touch screen, its recommended to use the RX845 Touch Cover.
3BSE042235R1
Panel 800 - PP865 15 Touch panel. TFT 1024 x 768 pixels, graphics & text, touch, color. To protect the touch screen, its recommended to use the RX865 Touch Cover.
3BSE042236R1
Panel 800 - PP865S 15 Touch panel. TFT 1024 x 768 pixels, graphics & text, touch, color, stainless steel front.
3BSE042242R1
Article no. Panel Builder 800 version 5.0 Media folder with Panel Builder 800 containing the latest version of: - Panel Builder 800 and Panel Tools - Firmware for panels - Manuals as pdf-files - Release Notes - License for one Panel Builder 800 1 year Automation Sentinel Subscription included. 3BSE042250R1
Accessories
Connection Cables for Panel 800
Article no. TK854V030 Programming Cable RS232 programming cable Panel 800 <--> PC. Length 3 m. TK212A Tool cable RJ45 (male) to Dsub-9 (female), length 3 m. RJ45 8P8C plug (with shell). Cable : UL2464 26 AWG x 8C. For serial communication between Panel 800 and AC 800M. 3BSC630197R1 3BSE042251R1
Article no. CB801 PROFIBUS DP Communication Interface PROFIBUS DP slave expansion module for Panel 800. CB810 USB to Ethernet adapter for programming USB to Ethernet adapter with software. Cross over Ethernet patch cable included. 3BSE042255R1 3BSE042245R1
Miscellaneous
Article no. RX825 Touch cover for PP825, 1 pcs RX835 Touch cover for PP835, 1 pcs RX845 Touch cover for PP845, 1 pcs RX865 Touch cover for PP865, 1 pcs Not suitable for PP865S. MB801V512 Compact Flash card Expansion Compact Flash memory for Panel 800, 512 MB.
System 800xA Product Catalog | Panel 800 75
Solutions - Media
Solutions - Media
Article no. INFI90 Function Code Library for AC 800M CD/DVD Media - INFI90FCLib Latest Revision. MOD 300 CCF Library for AC 800M CD/DVD Media - MOD 300 CCFLib latest revision. 3BUA000941R200 3BUA000936R200
Dongles
Dongles
Article no. RAINBOW SuperPro Dongle for USB Port RAINBOW SuperPro Dongle for Parallel Port 3BSE034584R1 3BSE034585R1
System
Article no. System 800xA 5.1 Installation System 800xA 5.1 Automated Installation System 800xA 5.1 Upgrade System 800xA 5.1 Network Configuration System 800xA Engineering 5.1 Engineering Studio Topology Designer System 800xA 5.1 Administration and Security System 800xA 5.1 Post Installation System 800xA 5.1 Configuration System 800xA 5.1 Basic Operation System 800xA Operations 5.1 System 800xA 5.1 System Planning System 800xA 5.0 Site Preparation System 800xA 5.1 Tools System 800xA 5.1 Multisystem Integration System 800xA 5.1 Maintenance 3BSE037410-510 3BUA000156-510 3BDS011222-510 3BSE036903-510 3BSE036904-510 3BSE041389-510 3BUA000258R5001 2PAA101888-510 3BSE037076-510 3BSE046784-510 3BSE034678-510 3BSE034679-510 3BSE036342-510 3BSE034463-510 3BDS011225-510
Connectivity
800xA for Advant Master
Article no. 800xA for Advant Master 5.1 Configuration 800xA for Advant Master 5.1 Operation 800xA for Advant Master 5.1 Graphic Library 800xA for Advant Master 5.1 Extended Graphic Library 3BSE030340-510 3BSE030352-510 3BSE030430-510 3BSE026427-510
Article no. System 800xA for DCI 5.0, Operation. System 800xA for DCI 5.0 SP 2, Configuration. 3BUA000129R5001 3BUA000135R5021
Article no. 800xA for Harmony 5.1 Configuration 800xA for Harmony 5.1 Operation 3BUA000157-510 3BUA000158-510
800xA for Melody Documentation for 800xA for Melody - Operation (Faceplate documentation) is not included in the product price and can be ordered market specific via ABB Utility Automation or ABB Process Industries.
Article no. 800xA for AC 870P/Melody 5.1 Configuration 3BDD011741-510
Connectivity
800xA for MOD 300
Article no. 800xA for MOD 300 5.1 Configuration 800xA for MOD 300 5.1 Operation 3BUR002417-510 3BUR002418-510
PLC Connect
Article no. System 800xA 5.1 PLC Connect Operation System 800xA 5.1 PLC Connect Configuration 3BSE035040-510 3BSE035041-510
Article no. System 800xA 5.0 SP2 800xA for Safeguard Configuration 800xA for Safeguard 5.1 Operation 800xA for Safeguard 5.1 Graphic Library 3BNP004848R5021 3BNP004849-510 3BSE044423-510
Article no. System 800xA Operations 5.1 Operator Workplace Configuration 3BSE030322-510
Article no. System 800xA Batch Management 5.1 Configuration System 800xA Batch Management 5.1 Operation 3BUA000146-510 3BUA000145-510
Article no. System 800xA Information Management 5.1 Getting Started System 800xA Information Management 5.1 Configuration System 800xA Information Management 5.1 Display Services System 800xA Information Management 5.1 Operation 3BUF001094-510 3BUF001091-510 3BUF001092-510 3BUF001093-510
Article no. System 800xA Asset Optimization 5.1 Configuration System 800xA Asset Optimization 5.1 Operation System 800xA 5.1 PC, Network and Software Monitoring Operation System 800xA 5.1 PC, Network and Software Monitoring Configuration 3BUA000447-510 3BUA000118-510 3BUA000150-510 3BUA000446-510
Article no. System 800xA Engineering 5.1 Concepts System 800xA Engineering 5.1 Engineering Studio System 800xA Engineering 5.1 Engineering Studio Function Designer System 800xA Process Graphics Extension 5.0 SP2, Installation System 800xA Engineering 5.1 Process Graphics System 800xA Engineering 5.1 Process Graphics Migration Tool System 800xA Engineering 5.1 Process Graphics based on Visual Basic System 800xA Engineering 5.1 Aspect Studio System 800xA Engineering 5.0, Aspect Express System 800xA Engineering 5.1 Process Engineering Tool Integration System 800xA Engineering 5.1 Engineering Studio Function Designer Getting Started System 800xA Engineering 5.0 SP2, Engineering in Environments 3BSE045030R5021 3BDS100968-510 3BSE032792-510 3BSE032793R5001 3BUA000184-510 3BSE030335-510 3BSE049230-510 3BSE049231-510 3BUA001135R5022 3BDS100972-510 3BDS011223-510 3BDS011224-510
Article no. System 800xA Control 5.1 AC 800M Getting Started System 800xA Control 5.1 AC 800M Configuration System 800xA Control 5.1 AC 800M Binary and Analog Handling AC 800M 5.1 Communication Protocols AC 800M FOUNDATION Fieldbus HSE AC 800M 5.1 OPC Server System 800xA Control 5.1 AC 800M Planning AC 800M 5.1 Library Object Style Guide AC 800M PROFIBUS DP Configuration AC 800M PROFIBUS DP Installation AC 800M 5.1 PROFINET I/O Configuration AC 800M 5.0 AC 800M DriveBus AC 800M 5.1 Ethernet/IP DeviceNet Installation AC 800M 5.1 Ethernet/IP DeviceNet Linking Device LD 800DN AC 800M 5.1 Ethernet/IP DeviceNet Configuration AC 800M 5.1 Controller Hardware AC 800M Advant Fieldbus 100 800xA for TRIO/Genius 5.1 800xA for TRIO/Genius 5.1 Getting Started AC 800M 5.1 IEC 61850 Configuration S800 I/O Getting Started S800 I/O Modules and Termination Units S800 I/O Fieldbus Communication Interface for PROFIBUS DP/DPV1 S800 I/O Modules and Termination Units with Intrinsic Safety S200 I/O 4.1 Hardware S200L I/O 4.1 Hardware S800 I/O DTM 5.3 AC 800M 5.0 Interfacing SATT I/O 3BSE021356R4101 3BSE021357R4101 3BSE027630-510 3BSE042821R5001 3BSE020927-510 9ARD000015-510 3BSE036351-510 3BSE000506-510 3BUR002460-510 3BUR002459-510 9ARD171385-510 3BSE020923-510 3BSE020924-510 3BSE020926-510 3BSE035982-510 3BDD012903-510 3BSE035983-510 3BSE043732-510 3BSE042835-510 3BDS009030-510 3BDS009029-510 3BDS021515-510 3AFE68237432E 9ARD000013-510 9ARD000014-510 3BSE041880-510 3BSE035980-510 3BSE035981-510
Article no. System 800xA Safety 5.1 AC 800M High Integrity Safety Manual 3BNP004865-510
S900 I/O
For S900 I/O documentation, please, refer to the S900 I/O and Fieldbus Network Components price book, 2PAA102823.
Article no. System 800xA Device Management 5.1 Device Library Wizard 2PAA102573-510
Article no. System 800xA Device Management 5.1 FOUNDATION Fieldbus Configuration 3BDD012902-510
Article no. System 800xA Device Management 5.1 PROFIBUS and HART Configuration System 800xA Fieldbus - Basic PROFIBUS DTM 5.1/5.2, Configuration IndustrialIT, Fieldbus Basic HART DTM 5.1, Configuration. 3BDD011939R5101 3BDD011938R5101 3BDD011934-510
Article no. Media CD-ROM LD 800HSE Version 3.2, English Documentation in pdf-format, tools, capabilities file, and bitmaps for LD 800HSE. Media CD-ROM LD 800HSE Version 3.3.0, English Documentation in pdf-format, tools, capabilities file, and bitmaps for LD 800HSE. Printed User Instructions LD 800HSE Version 3.2, English Describes in detail the FOUNDATION Fieldbus Linking Device LD 800HSE features, hardware installation, configuration, and diagnostics. Printed User Instructions LD 800HSE Version 3.3.0, English Describes in detail the FOUNDATION Fieldbus Linking Device LD 800HSE features, hardware installation, configuration, and diagnostics. 3BDD011677R0501 3BDD011677R0401 3BDD011678R0501 3BDD011678R0401
Reference documentation
This document includes listings of the Release Notes and User Instructions applicable for 800xA System Version 5.1. The listings include the title of the document and the corresponding document number. The documents are grouped by functional areas within the system and by Release Notes and User Instructions. Release Notes This table lists the Release Notes and applicable document numbers that are released for use with 800xA System Version 5.1.
Functional Area 800xA System System 800xA 5.1 Release Notes Fixed problems System 800xA 5.1 Release Notes New functions and known problems 2PAA106188-510 Document number. 2PAA106187-510
User Instructions This table lists the User Instructions and associated document numbers that are released for use with 800xA System Version 5.1.
Functional Area System 800xA Document title System 800xA 5.1 Tools System 800xA 5.1 Configuration System 800xA 5.1 Network Configuration System 800xA 5.1 Installation System 800xA 5.1 Automated Installation System 800xA 5.1 Upgrade System 800xA 5.1 Multisystem Integration System 800xA 5.1 Administration and Security System 800xA 5.1 System Planning System 800xA 5.1 Maintenance System 800xA 5.1 Post Installation System 800xA 5.1 Site Planning System 800xA 5.1 Server Node Virtualization System Guide System 800xA 5.1 System Guide Functional Description System 800xA 5.1 System Guide Technical Data and Configuration 3BSE041434-510 3BSE038018-510 3BSE056141-510 3BUA000258-510 3BUA000156-510 3BSE046784-510 3BSE041389-510 3BSE037410-510 3BSE036342-510 3BSE037076-510 3BSE034678-510 3BSE034679-510 3BSE034463-510 Document number. 2PAA101888-510 3BDS011222-510
Reference documentation
Document title System 800xA Asset Optimization 5.1 Configuration System 800xA Asset Optimization 5.1 Operation
System 800xA 5.1 PC, Network, and Software Monitoring Operation System 800xA 5.1 PC, Network, and Software Monitoring Configuration
3BUA000447-510
AC800M
AC 800M 5.0 SP2, 5.1 AC800M DriveBus AC 800M Foundation Fieldbus HSE AC 800M 5.0, 5.1 PROFIBUS DP Installation AC 800M 5.0 SP1, 5.1 PROFIBUS DP Configuration AC 800M 5.1 Communication Protocols AC 800M 5.1 OPC Server AC 800M 5.1 Controller Hardware AC 800M 5.0, 5.1 Interfacing SATT I/O AC 800M 5.1 Library Object Style Guide AC 800M 5.1 IEC 61850 Configuration AC 800M 5.1 PROFINET IO Configuration AC 800M 5.1 Ethernet/IP DeviceNet Configuration AC 800M 5.1 Ethernet/IP DeviceNet Installation
3AFE68237432D E 3BDD012903-510 3BDS009029R5001 A 3BDS009030R5011 A 3BSE035982-510 3BSE035983-510 3BSE036351-510 3BSE042821R5001 3BSE042835-510 9ARD171385-510 3BDS021515-510 9ARD000014-510 9ARD000015-510 3BSE035980-510 3BSE035981-510
Control
System 800xA Control 5.1 AC 800M Configuration System 800xA Control 5.1 AC 800M Binary and Analog Handling System 800xA Control 5.1 AC 800M Getting Started System 800xA Control 5.1 AC 800M Planning Advant Fieldbus 100 User Manual
Reference documentation
Document title System 800xA Device Management 5.1 Device Library Wizard System 800xA Device Management 5.1 FOUNDATION Fieldbus Configuration System 800xA Device Management 5.1 PROFIBUS and HART Configuration Device Management Basic PROFIBUS DTM 5.3 Device Management Basic HART DTM 5.2 Field IT - Linking Device Integration Pepperl+Fuchs Power Hub Device Management PROFIBUS DP/FMS Redundancy Link Module, RLM01 Device Management FOUNDATION Fieldbus Linking Device, LD 800HSE 3.4.0/0 Device Management PROFIBUS DTM Builder 5.3 Device Management HART DTM Builder 5.2
3BDD012902-510
3BDD011934-510
3BDD011600R0601 A
3BDD011677R0601
System 800xA Engineering 5.1 Engineering Studio System 800xA Engineering 5.1 Engineering Studio Function Designer System 800xA Engineering 5.1 Engineering Studio Function Designer Getting Started System 800xA Engineering 5.1 Process Graphics based on Visual Basic System 800xA Engineering 5.1 Aspect Studio System 800xA Engineering 5.1 Aspect Express System 800xA Engineering 5.1 Engineering and Production Environments System 800xA Engineering 5.1 Engineering Studio Topology Designer System 800xA Engineering 5.0 SP2, 5.1 Process Engineering Tool Integration System 800xA Engineering 5.1 Process Graphics System 800xA Engineering 5.1 Process Graphics Migration Tool
3BDS100968-510
3BSE030335-510
3BDS011225-510
3BUA000184R5021 B
3BSE049230-510 3BSE049231-510
Reference documentation
Document title System 800xA IEC 61850 5.1 Engineering Workflow System 800xA IEC 61850 5.1 Configuration
Information Management
System 800xA Information Management 5.1 Getting Started System 800xA Information Management 5.1 Configuration System 800xA Information Management 5.1 Display Services System 800xA Information Management 5.1 Data Access and Reports
3BUF001092-510 3BUF001093-510
3BUF001094-510
I/O
S900 I/O DTM 3.0.x S900 I/O S- and N-System with SA920 Installation S900 I/O PROFIBUS DP Communication Interface, CI920 1.4 S900 I/O Digital I/O Modules DO910 and DX910 S900 I/O Frequency Input/ Pulse Counter DP910N/ DP910S S900 I/O Analog I/O Modules (HART) AI930, AI931, AO930 S900 I/O Temperature Input AI950 S900 I/O B-System with SA920 Installation S900 I/O PROFIBUS DP Communication Interface, CI920 1.5 S900 I/O Digital I/O Relay Module DO930N S800 I/O Getting Started S800 I/O Modules and Termination Units S800 I/O Fieldbus Communication Interface for PROFIBUS DP/DPV1 S800 I/O Modules and Termination Units with Intrinsic Safety Interface S800 I/O DTM 5.3 S200 I/O Hardware S200L I/O Hardware
3BDD010423R0201 A 3BDD010424R0201 A
3BSE020927-510
System 800xA Operations 5.1 Operator Workplace Configuration System 800xA Operations 5.1
3BSE036904-510
Reference documentation
Document title System 800xA 5.1 PLC Connect Operation System 800xA 5.1 PLC Connect Configuration
Document number. 3BSE035040-510 3BSE035041-510 3BUA000145-510 3BUA000146-510 3BSE026427-510 3BSE030340-510 3BSE030352-510 3BSE030430-510 3BUA000157-510 3BUA000158-510 3BDD011741-510 3BUR002417-510 3BUR002418-510 3BNP004848-510 3BNP004849-510 3BSE044423-510 3BUR002459-510 3BUR002460-510
Batch Management
System 800xA Batch Management 5.1 Operation System 800xA Batch Management 5.1 Configuration
800xA for . . .
Advant Master 800xA for Advant Master 5.1 Extended Graphic Library 800xA for Advant Master 5.1 Configuration 800xA for Advant Master 5.1 Operation 800xA for Advant Master 5.1 Graphic Library Harmony 800xA for Harmony 5.1 Configuration 800xA for Harmony 5.1 Operation Melody MOD 300 800xA for AC870P / Melody 5.1 Configuration 800xA for MOD 300 5.1 Configuration 800xA for MOD 300 5.1 Operation Safeguard 800xA for Safeguard 5.1 Configuration 800xA for Safeguard 5.1 Operation 800xA for Safeguard 5.1 Graphic Library TRIO/Genius 800xA for TRIO/Genius 5.1 Getting Started 800xA for TRIO/Genius 5.1
Contact us
ABB AB Open Control Systems Vsters, Sweden Phone: +46 (0) 21 32 50 00 Fax: +46 (0) 21 13 78 45 E-Mail: processautomation@se.abb.com www.abb.com/controlsystems
Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB. The IndustrialIT wordmark, Aspect Objects, and all above mentioned names in the form xxxxxxIT are registered or pending trademarks of ABB. All rights to other trademarks reside with their respective owners. Copyright 2010 ABB. All rights reserved.
ABB Inc. Open Control Systems Wickliffe, Ohio, USA Phone: +1 440 585 8500 Fax: + 1 440 585 8756 E-Mail: industrialitsolutions@us.abb.com www.abb.com/controlsystems
ABB Pte Ltd Open Control Systems Singapore Phone: +65 6776 5711 Fax: +65 6778 0222 E-Mail: processautomation@sg.abb.com www.abb.com/controlsystems
ABB Automation GmbH Open Control Systems Mannheim, Germany Phone: +49 1805 26 67 76 Fax: +49 1805 77 63 29 E-Mail: marketing.control-products@de.abb.com www.abb.de/controlsystems
ABB Automation LLC Open Control Systems Abu Dhabi, United Arab Emirates Phone: +971 (0) 2 417 1333 Fax: +971 (0) 2 626 3230 E-Mail: processautomation@ae.abb.com www.abb.com/controlsystems
Aug 2010