NT 600
Modular Wiring Tester

■ Easy operation via PC with control software ■ The NT 600 is the ideal entry-level tester –
NT Control easy expandable for future test requirements
■ Comfortable test program editors ■ Low start-up costs
■ Extensive display possibilities and tools for fault location ■ Easy expandable*:
in the unit under test ▪ Additional measurement electronics
■ Extensive result reporting to file, to printer or via ▪ LCR measurement bridge
database connection* ▪ Test point expansion via test point units
■ Up to 1024 test points in the base unit, expandable via ▪ Four-wire measurement from 1 mOhm
additional units up to max. 5120 test points ▪ Insulation tests up to 10 GOhm
■ Continuity test, short circuit test and component test ■ Test table support
■ High current test up to 2 ADC* ■ The demands of the following test standards
■ High voltage test up to 1500 VDC* are complied with:
■ Dielectric strength test up to 1060 VAC / 1500 VDC* IPC/WHMA-A-620, MIL-STD-202G,
■ Remote maintenance NASA-STD 8739.4A, MIL-HDBK-83575,
MIL-STD-1344A, MIL-C-45224D

* optional

TESTING
NT 600
Options
Measurement electronics expansion
to the base equipment MT20 up to 25 VDC / max. 25 mA
■ Measurement electronics:
▪ MT40-40 up to 40 VDC / max. 100 mA
▪ MT40-250 up to 250 VDC / max. 10 mA
▪ MT1500DC up to 1500 VDC / max. 2 A
High voltage insulation test / high current continuity test
(optional up to 40 VDC / 10 A pulsed)
▪ MT2000 up to 1060 VAC / 1500 VDC
Dielectric strength test, max 3 mA or 6 mA
■ Internal AC measurement bridge MT_LCR for the test of
inductances, capacitances and resistances
■ Voltage measurement device MT_EXT for the voltage measurement
up to 700 VDC and 500 VAC (max. 400 Hz)
■ Four-wire (Kelvin) measurement for measuring low resistances from
1 mOhm

Function test
■ Stimulus cards
■ Stimulus sources
■ Test and programming of one-wire devices
■ Total integration of camera systems for visual tests
■ ProfiNet, LIN-, CAN-, Mod-Bus TCP, other bus systems on request

Elaborate number of interfaces


■ Digital inputs and outputs 24 V
■ Interface for test point units (standard)
■ Extern Interface (standard)
■ Safety loop (standard)
etc.

NT Control test and programming software


■ Graphic user interface with clear test display
▪ Operating buttons, test status, statistics
▪ In the error case display as error list or single error
■ Editors for net lists, link lists, insulation point lists (prim lists)
and component lists, function test editor
■ Easy realization of special test procedures
■ Comfortable multimeter function
■ NT Control is part of the delivery!

For further information about the wide-range of features please


note the NT Control product information.

www.adaptronic.de Competence in Testing.


NT 600
Options
Open Wire Probe
■ Intelligent pin number probe
■ Test point display
■ Status display
■ Operation modes automatic and manual

Operating and display options


■ Foot switch for test start
■ Warning lamp for high voltage tests
■ Test result lamp

Temperature and humidity logging


■ Combined temperature and humidity sensor
■ Interface at the NT 600
■ Temperature and humidity available in NT Control

Comprehensive possibilities of interface boards and adapter cables


■ Interface boards for the adaption of the adaptronic interface
to existing adapter cable connector systems
■ Adapter cables with adaptronic standard interfaces, open cable
ends for the adaption by the client or application specific special
adapter cables

Test point units


■ Up to 1024 test points each unit
■ Max. 4 test point units with max. 4096 test points can be operated
from a NT 600 (with max. 1024 test points)
■ Positioning of the base unit and the test point units directly side by
side or one upon the other

Additional services
■ Training for programming and testing with NT Control and NT 600
■ Calibration service
■ Application specific assistance

www.adaptronic.de Competence in Testing.


NT 600
Test program generation and testing with NT Control
With the user friendly software NT Control it is comfortable to generate, edit and to manage test programs as
well, as to carry out tests. The data transfer between a PC with NT Control and a NT 600 takes place via
network. NT Control is necessary for the operation of the NT 600 and part of the delivery. NT Control can be
run on a PC* with the operating system Microsoft Windows® 7 Pro up to Windows® 10 Pro (country variants
German or English).

Technical features NT 600


Test points max. 1024 in the base unit (expandable with test point units up to 5120 test points)

Low voltage test DC


Test voltage max. 25 V (optional up to 250 V)
Test current max. 25 mA (optional up to 100 mA)
Threshold continuity test 1 Ohm – 1 kOhm
Threshold short-circuit test 20 kOhm – 1 MOhm (optional up to 100 MOhm)
Component test Resistors: 1 Ohm – 1 MOhm (optional up to 100 MOhm)
Capacitors: 10 nF – 20 mF (optional from 10 pF)
Diodes, Zener diodes, LEDs, optional: inductances, impedances, varistors
(max. 1300 VDC)

High current test DC (optional)


Test voltage max. 22 V
Test current max. 2 A (optional 10 A pulsed)
Threshold continuity test 0,5 Ohm – 1 kOhm
Options Four-wire measurement from 1 mOhm / Recognition of short time interruptions ≥ 1 µs

High voltage test DC (optional)


Test voltage 40 – 1500 V
Insulation test 500 kOhm – 2 GOhm (optional up to 10 GOhm)
Breakdown test Fast recognition of voltage breakdowns (arc detection)

Dielectric strength test AC/DC (optional)


Test voltage / test current AC 100 – 1060 V / max. 3 mA, safety current limited according to EN 50191 (optional max. 6 mA)
Test voltage / test current DC 40 – 1500 V / max. 3 mA, safety current limited according to EN 50191 (optional max. 6 mA)

Function test (optional)


The NT 600 can be expanded, so that the test of relays, time relays, contactors, indication
lamps, function procedures etc. can be carried out automatically. Therefore stimulus cards and
stimulus sources are available beside powerful software tools and editors in NT Control.

General
Interfaces Interface for expansion units
Extern interface with 3 opto-coupled inputs and 3 potential free outputs (expandable)
Serial interfaces RS232 / USB 2.0
Network
Pin number probe
Dimensions (W x H x D, approx.) Base unit: 450 mm x 275 mm x 395 mm
Test point unit 0ZE31: 450 mm x 150 mm x 395 mm
Scope of delivery base unit NT 600, main cable, pin number probe, USB flash drive with NT Control and documentation in
PDF format, mating connector and service connector for safety loop
* PC not in the scope of delivery

Technical changes reserved – copyright 2019 adaptronic Prüftechnik GmbH, DE-97877 Wertheim – PI-04-066-J