Northman Directional Control Valves 2019
Northman Directional Control Valves 2019
Northman Directional Control Valves 2019
com 2
Index
Direconal Control Valves Page(s)
+ Solenoid Valves
NFPA D03 (SWHG02) 4
NFPA D03M (SWHG02M) 13
NFPA D05 (SWHG03) 20
NFPA D05M (SWHG03M) 31
NFPA D07 (SWG04) 37
NFPA D08 (SWG06) 45
NFPA D10 (SWG10) 53
+ Manual Valves
NFPA D03 (HDG02) 61
NFPA D05 (HDG03) 64
NFPA D07 (HDG04) 67
NFPA D08 (HDG06) 70
+ Manual Valves Threaded Body
NPT Port Body (HDT03, T06) 73
+ Check Valves
InLine Check 77
Right Angle Check 80
P.O. Check 85
+ Subplates
M02 SUBPLATE 89
M03 SUBPLATE 91
M04 SUBPLATE 94
M06 SUBPLATE 96
M08 SUBPLATE 99
Northman www.northmanfp.com 3
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
FEATURES
• Armature operates in oil system. Impact is cushioned, noise is reduced and solenoid life is increased.
• Wet armature solenoid eliminates pushpin seal, therefore no seal wear or leakage for longer valve life.
• Molded coils for maximum insulang properes, which is impervious to moisture and dirt.
• Plugin solenoid, for ease of maintenance.
• All spools and bodies are interchangeable, simplifying maintenance.
• Indicang signal lights and bolt kits are standard.
• High pressure, high flow rang, and lowpressure drop.
• Specially designed, balanced spool allows proper shi&ing force, for maximum reliability and long life.
• Viton seal kits are available for fireresistance fluids.
Model Code
Northman www.northmanfp.com 4
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
SPECIFICATIONS:
Maximum opera ng pressure 310 BAR (4500 PSI)
Rated flow capacity 63 LPM (16.8 GPM) MAX Varies by spool type
Maximum tank line back pressure 138 BAR (2000 PSI)
Maximum frequencies of opera on 300 CPM
Recommended filtra on 25 MICRON
Hydraulic fluids Mineral Oil, Viscosity 10 400 cST
Temperature range 25° C to +90° C (13° F to +194° F)
SOLENOID RATINGS:
TECHNICAL DATA:
• Solenoid can be used within 10% to +10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insula on resistance over 100mQ
• Conforms to ra ng IP65
• A momentary signal of approx 0.1 second is required for shi@ing ac on.
ACCESSORIES:
• Moun ng bolt kits are supplied with valve socket head cap screws
(#1024UNCx13/4"L 4 pcs) for ghtening torque 5070 kgfcm (43.360.6 lbin).
• ORing AS568012 4 pcs.
Northman www.northmanfp.com 6
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
1. Tes ng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. ThroGle Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 63 LPM(16.8GPM)
Viscosity: 35 cSt (175SSU)
Northman www.northmanfp.com 7
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
LIST OF SPOOL FUNCTIONS:
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE
50 BAR 100 BAR 150 BAR 207 BAR 250 BAR 310 BAR 50 BAR 100 BAR
NORMAL POSITION
(735 PSI) (1470 PSI) (2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI) (735 PSI) (1470 PSI)
40 (10.7) 40 (10.7)
C2 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32 (8.5) 40 (10.7)
C3 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
40 (10.7) 40 (10.7)
C4 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32 (8.5) 25 (6.7)
40 (10.7) 40 (10.7)
C40 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32 (8.5) 25 (6.7)
C5 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3)
C6 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7)
40 (10.7) 40 (10.7)
C7 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32 (8.5) 25 (6.7)
40 (10.7) 40 (10.7)
C8 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32(8.5) 25 (6.7)
40 (10.7) 40 (10.7)
C9 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
32 (8.5) 25 (6.7)
B2 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 20(5.3)
B3 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
B20 35 (9.3) 32 (8.5)
D2 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 40 (10.7) 30 (8.0)
D3 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 40 (10.7) 30 (8.0)
1. The figures in the square show the flow under saturated temperature and 90%
rated voltage.
2. The upper number in table describes the maximum flow under DC and R. the
lower number in table describes the maximum flow under AC.
Northman www.northmanfp.com 8
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
150 BAR 207 BAR 250 BAR 310 BAR 50 BAR 100 BAR 150 BAR 2O7 BAR 250 BAR 310 BAR
(2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI) (735 PSI) (1470 PSI) (2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9.(2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9.(2.4) 7 (1.9) 7(1.9)
63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9 (2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9 (2.4) 7 (1.9) 7(1.9)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9 (2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9 (2.4) 7 (1.9) 7(1.9)
50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3) 50 (13.3)
40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7) 40 (10.7)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9 (2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9 (2.4) 7 (1.9) 7(1.9)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9 (2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9 (2.4) 7 (1.9) 7(1.9)
18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7) 40 (10.7) 40 (10.7) 18 (4.8) 14 (3.7) 10 (2.7) 10 (2.7)
12 (3.2) 9 (2.4) 7 (1.9) 7 (1.9) 32 (8.5) 25 (6.7) 12 (3.2) 9 (2.4) 7 (1.9) 7(1.9)
20 (5.3) 20 (5.3) 20 (5.3) 20 (5.3) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
63 (16.8) 63 (16.8) 63 (16.8) 37 (9.9) 30 (8.0) 28 (7.5)
63 (16.8) 63 (16.8) 63 (16.8) 63 (16.8)
45 (12.0) 45 (12.0) 45 (12.0) 45 (12.0) 45 (12.0) 45 (12.0)
63 (16.8) 50 (13.3) 45 (12.0) 40 (10.7) 32 (8.5) 25 (6.7)
25 (6.7) 20 (5.3) 18 (4.8) 15 (4)
45 (12.0) 30 (8.0) 28 (7.5) 25 (6.7) 22 (5.9) 18 (4.8)
25 (6.7) 21 (5.6) 16 (4.3) 13 (3.5) 40 (10.7) 30 (8.0) 25 (6.7) 21 (5.6) 16 (4.3) 13 (3.5)
25 (6.7) 21 (5.6) 16 (4.3) 13 (3.5) 40 (10.7) 30 (8.0) 25 (6.7) 21 (5.6) 16 (4.3) 13 (3.5)
Northman www.northmanfp.com 9
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES
TEST CONDITIONS
Pressure: 138 BAR (2000PSI)
Flow Rate: 30 LPM(8 GPM)
Viscosity: 35 cSt(175 SSU)
kg(lb)
1.5(3.3)
2.0(4.4)
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
FEATURES
• Armature operates in oil system. Impact is cushioned, noise is reduced, solenoid life is increased.
• Wet armature solenoid eliminates pushpin seal, therefore no seal wear, drop or leakage for longer valve life.
• Molded coils for maximum insula7ng proper7es, which is impervious to moisture and dirt.
• Plugin solenoid, for ease of maintenance.
• All spools and bodies are interchangeable, simplifying maintenance.
• Indica7ng signal lights and bolt kits are standard.
• High pressure, high flow ra7ng, provides lowpressure drop, with maximum performance.
• Specially designed, balanced spool allows proper shi:ing force, for maximum reliability and long life.
• A specially machined spool minimizes hydraulic shock caused by abrupt change in the flow condi7on at flow
cut off.
• Hydraulic shock caused by abrupt change in the flow condi7on at flow cut off, is minimized by a specially
machined
Model Code
SOLENOID OPERATED DIRECTIONAL VALVE
SWHG02 SERIES SHOCKLESS TYPE
Northman www.northmanfp.com 14
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
SPECIFICATIONS:
SOLENOID RATINGS:
TECHNICAL DATA:
• Solenoid can be used within 10% to +10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insula on resistance over 100mQ
• Conforms to ra ng IP65
• A momentary signal of approx 0.1 second is required for shiAing ac on.
ACCESSORIES:
• Moun ng bolt kits are supplied with valve socket head cap screws (#1024UNCx1
3/4"L 4 pcs)
for ghtening torque 5070 kgfcm (43.360.6 lbin).
• ORing AS568012 4 pcs.
Northman www.northmanfp.com 15
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
TEST SYSTEMS
1. Tesng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. Thro le Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 40 LPM(10.5GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
Northman www.northmanfp.com 16
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
TEST SYSTEMS
TEST CIRCUIT
1. Tesng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. Thro le Valve
TEST CONDITIONS
Pressure: 138 BAR (2000PSI)
Flow Rate: 30 LPM(8 GPM)
Viscosity: 35 cSt(175 SSU)
Northman www.northmanfp.com 17
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
Northman www.northmanfp.com 18
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G02 SERIES SHOCKLESS TYPE
Northman www.northmanfp.com 19
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
FEATURES
Model Code
Northman www.northmanfp.com 20
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
Northman www.northmanfp.com 21
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
SPECIFICATIONS
Maximum opera ng pressure 310 BAR (4500 PSI)
Maximum flow capacity 120 LPM (32 GPM)
Maximum tank line back pressure 160 BAR (2350 PSI)
Maximum frequencies of opera on 240 CPM
Recommended filtra on 25 MICRON
Hydraulic fluids Mineral Oil, Viscosity 10 400 Cst
Temperature range 25° C to +90° C (13° F to +194° F)
SOLENOID RATINGS
TECHNICAL DATA
• Solenoid can be used within 10% to + 10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insula on resistance over 100MQ.
ACCESSORIES
• Moun ng bolt kits are supplied with valve socket head cap screws M6x35L 4 pcs
(1/4"20UNCx13/8" 4 pcs) for ghtening torque 120150 kgfcm (104130 lbsin).
• ORing AS568014 5 pcs.
Northman www.northmanfp.com 22
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
PRESSURE DROP AND PERFORMANCE CURVES TEST CIRCUIT
TEST SYSTEMS
1. Tes ng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. ThroCle Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 140 LPM(37 GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
MODEL PRESSURE DROP CURVE NUMBER
NO. P—A B—T P—B A—T P—T
C2 6 6 6 6
C3 7 7 7 7 5
C4 6 7 6 7
C40 6 7 6 7
C5 5 2 2 5 8
C6 2 2 2 2 5
C60 1 1 1 1 4
C7 7 6 7 6
C8 6 6 6 7
C9 7 6 6 6
B2 2 2 6 6
B3 3 3 6 6
B20 5 5
B2S 6 6 2 2
B3S 6 6 3 3
B20S 5 5
cSt 15 20 30 40 50 60 70 80 90 100
VISCOSITY
SSU 77 98 141 186 232 278 324 371 417 464
FACTOR (G') 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
Northman www.northmanfp.com 23
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI) SWH G03 AC TYPE
SPOOL TYPE
NORMAL POSITION
50 BAR (735 100 BAR 150 BAR 207 BAR i 250 BAR 310 BAR 50 BAR (735 100 BAR
PSI) (1470 PSI) (2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI) PSI) (1470 PSI)
54(14.3)
C2 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
38(10.0)
C3 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
54(14.3)
C4 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
42(11.1)
100(26.4)
C40 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
75(19.8)
88(23.2) 88(23.2) 88(23.2) 88(23.2) 88(23.2)
C5 100(26.4) 100(26.4)
82(21.7) 82(21.7) 82(21.7) 82(21.7) 82(21.7)
84(22.2) 84(22.2) 84(22.2) 84(22.2) 84(22.2) 100(26.4) 100(26.4)
C6
75(19.8) 75(19.8) 75(19.8) 75(19.8) 75(19.8) 95(25.1) 95(25.1)
C7 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 63(16.6) 63(16.6)
100(26.4) 44(11.6) 30(7.9) 19(5.0) 100(26.4)
C8 100(26.4) 100(26.4) 100(26.4)
76(20.1) 28(7.4) 21(5.5) 14(3.7) 53(14)
C9 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 57(15.1) 57(15.1)
90(23.8) 90(23.8) 90(23.8) 90(23.8) 90(23.8) 90(23.8)
B2 63(16.6) 63(16.6)
72(19.0) 72(19.0) 72(19.0) 72(19.0) 72(19.0) 72(19.0)
89(23.5) 89(23.5) 89(23.5) 89(23.5) 89(23.5) 89(23.5)
B3 100(26.4) 100(26.4)
81(21.4) 81(21.4) 81(21.4) 81(21.4) 81(21.4) 81(21.4)
B20 81(21.4) 29(7.7)
D2 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 60(15.9) 40(10.6)
D3 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 70(18.5) 60(15.9)
NOTE: 1.The figures in the square shows the parameter among voltage & flow under saturated temperature
and 90% applied voltage.
2.The upper number in table describes the maximum flow under 100%.
3.The lower number in table describes the maximum flow under saturated temperature and 90% applied voltage.
Northman www.northmanfp.com 24
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI) SWH G03 AC TYPE
SPOOL TYPE
NORMAL
POSITION 150 BAR 207 BAR 250 BAR 310 BAR 50 BAR 100 BAR 150 BAR 207 BAR 250 BAR 310 BAR
(2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI) (735 PSI) (1470 PSI) (2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI)
40(10.6) 28(7.4) 25(6.6) 20(5.3) 100(26.4) 54(14.3) 40(10.6) 28(7.4) 25(6.6) 20(5.3)
C2
27(7.1) 17(4.5) 13(3.4) 10(2.6) 38(10.0) 27(7.1) 17(4.5) 13(3.4) 10(2.6)
C3 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
30(7.9) 23(6.1) 18(4.8) 14(3.7) 100(26.4) 54(14.3) 30(7.9) 23(6.1) 18(4.8) 14(3.7)
C4
27(7.1) 16(4.2) 11(2.9) 8(2.1) 42(11.1) 27(7.1) 16(4.2) 11(2.9) 8(2.1)
33(8.7) 28(7.4) 22(5.8) 18(4.8) 100(26.4) 100(26.4) 33(8.7) 28(7.4) 22(5.8) 18(4.8)
C40
23(6.1) 21(5.5) 15(4) 12(3.2) 75(19.8) 23(6.1) 21(5.5) 15(4) 12(3.2)
C5 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
C6
95(25.1) 95(25.1) 95(25.1)
95(25.1) 95(25.1) 95(25.1) 95(25.1) 95(25.1)
C7 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6) 63(16.6)
37(9.8) 34(9.0) 28(7.4) 20(5.3) 61(16.1) 33(8.7) 27(7.1) 20(5.3) 16(4.2)
C8 100(26.4)
32(8.5) 28(7.4) 21(5.5) 15(4) 48(12.7) 27(7.1) 21(5.5) 15(4) 9(2.4)
53(14) 47(12.4) 45(11.9) 40(10.6) 34(9.0)
C9 57(15.1) 57(15.1) 57(15.1) 57(15.1) 100(26.4)
40(10.6) 37(9.8) 34(9.0) 29(7.7) 25(6.6)
78(20.6) 45(11.9) 43(11.4) 38(10.0) 32(8.5)
B2 63(16.6) 63(16.6) 63(16.6) 63(16.6) 100(26.4)
74(19.6) 38(10.0) 36(9.5) 31(8.2) 27(7.1)
100(26.4) 95(25.1) 82(21.7) 75(19.8) 65(17.2)
B3 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
89(23.5) 84(22.2) 77(20.3) 70(18.5) 62(16.4)
80(21.1) 32(8.5) 25(6.6) 20(5.3) 14(3.7)
B20 19(5.0) 12(3.2) 9(2.4) 7(1.8) 100(26.4)
42(11.1) 28(7.4) 22(5.8) 17(4.5) 12(3.2)
D2 40(10.6) 40(10.6) 30(7.9) 28(7.4) 60(15.9) 40(10.6) 40(10.6) 40(10.6) 30(7.9) 28(7.4)
D3 60(15.9) 60(15.9) 42(11.1) 36(9.5) 70(18.5) 60(15.9) 60(15.9) 60(15.9) 42(11.1) 36(9.5)
Northman www.northmanfp.com 25
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI) SWH G03 DC TYPE
SPOOL
TYPE
NORMAL 50 BAR (735 100 BAR (1470 150 BAR (2200 207 BAR (3000 250 BAR (3675 310 BAR (4500 50 BAR 100 BAR
POSITION PSI) PSI) PSI) PSI) PSI) PSI) (735 PSI) (1470 PSI)
120(31.7)
C2 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7)
100(26.4)
C3 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7)
120(31.7)
C4 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7)
100(26.4)
120(31.7) 97(25.6) 78(20.6) 60(15.9) 120(31.7)
C40 120(31.7) 120(31.7) 120(31.7)
100(26.4) 75(19.8) 54(14.3) 41(10.8) 115(30.4)
C5 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
C6 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
C7 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 65(17.2) 65(17.2)
120(31.7) 97(25.6) 78(20.6) 66(17.4)
C8 120(31.7) 120(31.7) 120(31.7) 120(31.7)
100(26.4) 85(22.5) 54(14.3) 41(10.8)
Northman www.northmanfp.com 26
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI) SWH G03 DC TYPE
SPOOL
TYPE
NORMAL 150 bar 207 bar 250 bar 310 bar 50 bar 100 bar 150 bar 207 bar 250 bar 310 bar
POSITION (2200 psi) (3000 psi) (3675 psi) (4500 psi) (735 psi) (1470 psi) (2200 psi) (3000 psi) (3675 psi) (4500 psi)
73(19.3) 63(16.6) 54(14.3) 37(9.8) 120(31.7) 73(19.3) 63(16.6) 54(14.3) 37(9.8)
C2 120(31.7)
55(14.5) 48(12.7) 38(10.0) 29(7.7) 100(26.4) 55(14.5) 48(12.7) 38(10.0) 29(7.7)
C3 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7) 120(31.7)
90(23.8) 73(19.3) 60(15.9) 47(12.4) 120(31.7) 90(23.8) 73(19.3) 60(15.9) 47(12.4)
C4 120(31.7)
78(20.6) 64(16.9) 51(13.5) 39(10.3) 100(26.4) 78(20.6) 64(16.9) 51(13.5) 39(10.3)
75(19.8) 54(14.3) 42(11.1) 37(9.8) 120(31.7) 75(19.8) 54(14.3) 42(11.1) 37(9.8)
C40 120(31.7)
50(13.2) 39(10.3) 30(7.9) 21(5.5) 115(30.4) 50(13.2) 39(10.3) 30(7.9) 21(5.5)
C5 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
C6 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4) 100(26.4)
C7 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2) 65(17.2)
68(18.0) 51(13.5) 37(9.8) 27(7.1) 85(22.5) 50(13.2) 36(9.5) 25(6.6) 19(5.0)
C8 120(31.7)
52(13.7) 39(10.3) 28(7.4) 18(4.8) 65(17.2) 40(10.6) 28(7.4) 15(4) 12(3.2)
100(26.4) 94(24.8) 85(22.5) 76(20.1) 70(18.5)
C9 65(17.2) 65(17.2) 65(17.2) 65(17.2) 120(31.7)
85(22.5) 80(21.1) 74(19.6) 54(14.3) 49(12.9)
77(20.3) 63(16.6) 57(15.1) 45(11.9)
B2 69(18.2) 69(18.2) 69(18.2) 69(18.2) 120(31.7) 120(31.7)
66(17.4) 55(14.5) 44(11.6) 38(10.0)
100(26.4) 95(25.1) 82(21.7) 75(19.8) 65(17.2)
B3 120(31.7) 120(31.7) 120(31.7) 120(31.7) 100(26.4)
89(23.5) 84(22.2) 77(20.3) 70(18.5) 62(16.4)
120(31.7) 95(25.1) 74(19.6) 61(16.1) 43(11.4)
B20 28(7.4) 19(5.0) 15(4) 10(2.6) 120(31.7)
95(25.1) 84(22.2) 63(16.6) 50(13.2) 34(9.0)
D2 40(10.6) 40(10.6) 30(7.9) 28(7.4) 60(15.9) 40(10.6) 40(10.6) 40(10.6) 30(7.9) 28(7.4)
D3 60(15.9) 60(15.9) 42(11.1) 36(9.5) 70(18.5) 60(15.9) 60(15.9) 60(15.9) 42(11.1) 36(9.5)
Northman www.northmanfp.com 27
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
TEST SYSTEMS TEST CIRCUIT
1. Tesng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. Thro le Valve
TEST CONDITIONS
Pressure: 138 BAR (2000PSI)
Flow Rate: 30 LPM(8 GPM)
Viscosity: 35 cSt(175 SSU)
OPTION LS
FEATURES
• Suppresses the surge voltage.
• Eliminates sparks between relay contacts.
• Extends the life of the relay contact.
Northman www.northmanfp.com 28
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
Dimensions MOUNTING SURFACE: ISO 4401AB034A
UNIT: mm( inch)
SWH G03 A ** **** 10 **
with AC/DC/RF solenoids
MODEL WEIGHT
KGS (LBS)
SWHG03C**A*** 4.1(9.02)
SWHG03B**A*** 3.4(7.48)
WEIGHT KGS
MODEL
(LBS)
SWHG03C**D **
5.5(12.1)
SWHG03C**R ***
SWHG03B**D **
4(9.68)
SWHG03B**R ***
Northman www.northmanfp.com 29
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES
Northman www.northmanfp.com 30
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
FEATURES
Model Code
Northman www.northmanfp.com 31
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
Northman www.northmanfp.com 32
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
SPECIFICATIONS
Maximum opera ng pressure 207BAR (3000 PSI)
Maximum flow capacity 80 LPM (21 GPM) MAX. Varies by spool type
Maximum tank line back pressure 160 BAR (2350 PSI)
Maximum frequencies of opera on 240 CPM
Recommended filtra on 25 MICRON
Hydraulic fluids Mineral Oil, Viscosity 10 400 cST
Temperature range 0° C to +55° C (32° F to +131° F)
SOLENOID RATINGS
ELECTRIC COIL VOLTAGE(V) CURRENT & POWER AT RATED VOLTAGE
SOURCE TYPE
SOURCE RATED Hz RANGE (±10%) INRUSH CURRENT HOLDING WATTAGE
(A) CURRENT (A)
RF R110 AC110V 50 99126 0.47 0.47 46
AC110V 60
R220 AC220V 60 198253 0.24 0.24
AC220V 50
DC D12 DC 12V 10.813.2 2.58 2.58 32
D24 DC 24V 21.626.4 1.33 1.33
TECHNICAL DATA
• Solenoid can be used within 10% to + 10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insula on resistance over 100MQ.
ACCESSORIES
• Moun ng bolt kits are supplied with valve socket head cap screws M6x35L 4 pcs (1/4"20UNCx13/8"
4 pcs) for ghtening torque 120150 kgfcm (104130 lbsin).
• ORing AS568014 5 pcs.
Northman www.northmanfp.com 33
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
PRESSURE DROP AND PERFORMANCE CURVES TEST CIRCUIT
TEST SYSTEMS
1. Tes ng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. ThroEle Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 80 LPM(21 GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
SPOOL Pressure Drop Curve Number
TYPE
P—A B—T P—B A—T P—T
C2 1 1 1 1
C3 5 5 5 5 2
C4 1 1 1 1
C6 4 4 4 4 3
B2 2 2 2 2
B3 2 2 2 2
Northman www.northmanfp.com 34
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
RESULTS OF MEASUREMENTS TEST CIRCUIT
TEST SYSTEMS
1. Tes ng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. ThroEle Valve
TEST CONDITIONS
Pressure: 138 BAR (2000PSI)
Flow Rate: 30 LPM(8 GPM)
Viscosity: 35 cSt(175 SSU)
THE MAXIMUM FLOW RATE LPM(GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE
NORMAL 150 BAR 207 BAR 50 BAR 100 BAR 150 BAR 207 BAR 50 BAR 100 BAR 150 BAR 207 BAR
50 BAR 100 BAR
POSITION (2200 (3000 (735 (1470 (2200 (3000 (735 (1470 (2200 (3000
(735 PSI) (1470 PSI)
PSI) PSI) PSI) PSI) PSI) PSI) PSI) PSI) PSI) PSI)
80 80 80 80 80 67 80 80 80 67
C2 80 (21.5) 80 (21.5)
(21.5) (21.5) (21.5) (21.5) (21.5) (18.0) (21.5) (21.5) (21.5) (18.0)
80 67 80 50 80 50
C3 80 (21.5) 80 (21.5) 32 (8.5) 28 (7.5) 32 (8.5) 28 (7.5)
(21.5) (18.0) (21.5) (13.5) (21.5) (13.5)
80 80 80 80 80 80 80 80 80 80
C4 80 (21.5) 80 (21.5)
(21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5)
80 80
C6 80 (21.5) 30 (8) 28 (7.5) 20 (5.4) 35 (9.4) 30 (8) 20 (5.4) 35 (9.4) 30 (8) 20 (5.4)
(21.5) (21.5)
80 70 70 70 70 70 70 70 70
B2 80 (21.5) 80 (21.5) 28 (7.5)
(21.5) (18.5) (18.5) (18.5) (18.5) (18.5) (18.5) (18.5) (18.5)
80 80 80 80 80 80 80 80 80
B3 80 (21.5) 80 (21.5) 28 (7.5)
(21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5) (21.5)
Northman www.northmanfp.com 35
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G03 SERIES SHOCKLESS TYPE
Dimensions MOUNTING SURFACE: ISO 4401AB034A
UNIT: mm( inch)
SWH G03 *** **** 10 **
with DC/RF solenoids
MODEL WEIGHT
KGS (LBS)
SWHG03C**D ** 5.5(12.1)
SWHG03C**R ***
SWHG03B**D ** 4(9.68)
SWHG03B**R ***
Northman www.northmanfp.com 36
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
FEATURES
Model Code
Northman www.northmanfp.com 37
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
Northman www.northmanfp.com 38
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
SPECIFICATIONS
Maximum opera ng pressure 310 BAR (4500 PSI)
Maximum tank line back pressure 207 BAR (3000 PSI) externally drained
138 BAR (2000 PSI) internally drained
Pilot pressure Min. 8 BAR (113 PSI)
Max. 245 BAR (3550 PSI)
Maximum flow 300 LPM (80 GPM)
Weight SWG04C,D SERIES 8.2 kgs (18 lbs)
SWG04B SERIES 7.9 kgs (17.5 lbs)
OPTION ET
Northman www.northmanfp.com 39
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
SOLENOID RATINGS
ELECTRIC SOURCE COIL VOLTAGE CURRENT & POWER
TYPE Hz SOURCE RANGE INRUSH HOLDING WATTAGE
RATED (±10%) CURRENT (A) CURRENT (A)
AC A24 60 AC24V 21.626.4 6.8 1.7
(10 and 20 Op ons) 50 AC100V 90110 1.60 0.46
A110 AC100V 90110 1.40 0.32
60
AC110V 99121 1.50 0.39
50 AC110V 99121 1.30 0.38
A120
60 AC120V 108132 1.20 0.27
50 AC200V 180220 0.80 0.23
A220 AC200V 180220 0.70 0.16
60
AC220V 198242 0.75 0.19
50 AC220V 198242 0.67 0.1 9
A240
60 AC240V 216264 0.59 0.13
R 50 AC100V 90110 0.30 0.30
(10 and 20 Op ons) R110
60 AC110V 99121 0.30 0.30
50 AC200V 180220 0.15 0.15
R220
60 AC220V 198242 0.15 0.15
26
50 AC220V 180220 0.14 0.14
R240
60 AC240V 216264 0.14 0.14
DC D12 DC 12V 10.813.2 2.20 2.20
(10 and 20 Op ons) D24 DC 24V 21.626.4 1.10 1.10
DC D12 DC 12V 10.813.2 2.60 2.60
(31 and 41 Op ons) 28.8
D24 DC 24V 21.626.4 1.30 1.30
TECHNICAL DATA
• Solenoid can be used within 10% to + 10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insula on resistance over 100MQ.
• A momentary signal of approx 0.1 second is required for shi;ing ac on.
• Pilot pressure of internally drained valves must always exceed tank port pressure by a minimum of 8.0
BAR(113 PSI) Valve must be externally drained if there is a possibility of tank line pressure surges overcoming
this differen al.
• If the hydraulic circuit does not provide sufficient pilot pressure to shi; valves with open center spool con
figura ons C3, C5, C6, C60, do either: (1) Use the external pilot op on (“E“). Provide 113 PSI (8 Bar) minimum
pilot pressure to the “X” port on the manifold or subplate from another source in your system to shi; the
valve. (2) If the valve must be internally piloted in your system, then install back pressure of 113 PSI (8 Bar)
minimum at the tank line of the main valve. The valve must be externally drained (“T“) with this method.
• Conforms to IP65
ACCESSORIES
• Moun ng bolt kits are supplied with valve socket head cap screws
2 pieces 1/4" 20 UNC 2B x 1 3/4"L for ghtening torque 120150 kgfcm (104130 lbsin).
4 pieces 3/8" 16 UNC2B x 2"L for ghtening torque 580720 kgfcm (502624 lbsin).
• Oring P22A 4 pieces, P9 2 pieces.
Northman www.northmanfp.com 40
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
LIST OF SPOOL FUNCTIONS
NOTE: The upper number in table describes the maximum flow for standard type.The lower number in
table describes the maximum flow for shockless type.
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE NO SPRING
NORMAL 50 BAR (735 100 BAR (1470 150 BAR (2200 207 BAR (3000 250 BAR (3675 310 BAR (4500
POSITION PSI) PSI) PSI) PSI) PSI) PSI)
N2 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N3 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N4 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
N40 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE SPRING OFFSET
NORMAL 50 BAR (735 100 BAR (1470 150 BAR (2200 207 BAR (3000 250 BAR (3675 310 BAR (4500
POSITION PSI) PSI) PSI) PSI) PSI) PSI)
B2 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B3 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B4 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
B40 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0) 300(80.0)
Northman www.northmanfp.com 41
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
PRESSURE DROP AND PERFORMANCE CURVES TEST CIRCUIT
TEST SYSTEMS
1. Tes ng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. Thro-le Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 140 LPM(37 GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
Northman www.northmanfp.com 42
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
Dimensions MOUNTING SURFACE: ISO 4401AB034A
UNIT: mm( inch)
SW G04 ** **** 10
Northman www.northmanfp.com 43
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G04 SERIES
Northman www.northmanfp.com 44
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
FEATURES
Model Code
Northman www.northmanfp.com 45
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
Northman www.northmanfp.com 46
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
SPECIFICATIONS
Maximum opera ng pressure 310 BAR (4500 PSI)
Maximum tank line back pressure 207 BAR (3000 PSI) EXTERNALLY DRAINED
138 BAR (2000 PSI) INTERNALLY DRAINED
Pliot pressure MIN. 3.5 BAR (50 PSI)
MAX. 250 BAR (3550 PSI)
Maximum flow 500 LPM (133 GPM)
Weight SWG06 C/D SERIES 12.8 KGS (28 LBS)
OPTION ET
Northman www.northmanfp.com 47
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
SOLENOID RATINGS
ELECTRIC SOURCE COIL VOLTAGE CURRENT & POWER
TYPE Hz SOURCE RANGE INRUSH HOLDING WATTAGE
RATED (±10%) CURRENT (A) CURRENT (A)
AC A24 60 AC24V 21.626.4 6.8 1.7
(10 and 20 Opons) A110 50 AC100V 90110 1.60 0.46
60 AC100V 90110 1.40 0.32
AC110V 99121 1.50 0.39
A120 50 AC110V 99121 1.30 0.38
60 AC120V 108132 1.20 0.27
A220 50 AC200V 180220 0.80 0.23
60 AC200V 180220 0.70 0.16
AC220V 198242 0.75 0.19
A240 50 AC220V 198242 0.67 0.1 9
60 AC240V 216264 0.59 0.13
R110 50 AC100V 90110 0.30 0.30 26
60 AC110V 99121 0.30 0.30
R220 50 AC200V 180220 0.15 0.15
60 AC220V 198242 0.15 0.15
R240 50 AC220V 180220 0.14 0.14
60 AC240V 216264 0.14 0.14
DC D12 DC 12V 10.813.2 2.20 2.20
(10 and 20 Opons) D24 DC 24V 21.626.4 1.10 1.10
DC D12 DC 12V 10.813.2 2.60 2.60 28.8
(31 and 41 Opons) D24 DC 24V 21.626.4 1.30 1.30
TECHNICAL DATA
• Solenoid can be used within 10% to +10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insulaon resistance over 100MQ.
• A momentary signal of approx. 0.1 second is required for shi6ing acon.
• Pilot pressure of internally drained valves must always exceed tank port pressure by a minimum of 3.5 BAR
(50 PSI) Valve must be externally drained if there is a possibility of tank line pressure surges overcoming this
differenal.
• If the hydraulic circuit does not provide sufficient pilot pressure to shi6 valves with open center spool con
figuraons C3, C5, C6, C60, do either: (1) Use the external pilot opon (“E“). Provide 50 PSI (3.5 Bar) mini
mum pilot pressure to the “X” port on the manifold or subplate from another source in your system to shi6 the
valve. (2) If the valve must be internally piloted in your system, then install back pressure of 50 PSI (3.5 Bar)
minimum at the tank line of the main valve. The valve must be externally drained (“T“) with this method.
ACCESSORIES
• Mounng bolt kits are supplied with valve socket head cap screws M12x60L 6 pcs (1/2"13UNC2Bx2 3/8"L
6 pcs) for ghtening torque 10001230 kgfcm (886 1066 lbsin).
• ORing P28 90° 4 pcs and P21 90° 2 pcs.
Northman www.northmanfp.com 48
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
LIST OF SPOOL FUNCTIONS
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE SPRING CENTERED
NORMAL
50 BAR 100 BAR 150 BAR 207 BAR 250 BAR 310 BAR
POSITION
(735 PSI) (1470 PSI) (2200 PSI) (3000 PSI) (3675 PSI) (4500 PSI)
500(133.0) 500(133.0) 500(133.0) 450(120.0) 410(109.3) 310(82.6)
C2
500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
C3 500(133.0) 500(133.0) 500(133.0) 480(128.0) 460(122.6) 360(96.0)
500(133.0) 500(133.0) 500(133.0) 450(120.0) 410(109.3) 310(82.6)
C4
500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
500(133.0) 500(133.0) 500(133.0) 450(120.0) 410(109.3) 310(82.6)
C40
500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
C5 500(133.0) 500(133.0) 500(133.0) 450(120.0) 420(112.0) 350(93.3)
C6 500(133.0) 470(125.3) 400(106.6) 350(93.3) 300(80.0) 230(61.3)
500(133.0) 470(125.3) 425(113.3) 385(102.6) 340(90.6) 280(74.6)
C60
500(133.0) 470(125.3) 425(113.3) 385(102.6) 340(90.6) 280(74.6)
C7 500(133.0) 500(133.0) 500(133.0) 480(128.0) 450(120.0) 360(96.0)
500(133.0) 500(133.0) 500(133.0) 450(120.0) 410(109.3) 310(82.6)
C8
500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
500(133.0) 500(133.0) 500(133.0) 450(120.0) 410(109.3) 310(82.6)
C9
500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
NOTE: The upperside number in table describes the maximum flow for standard type.
The lowerside number in table describes the maximum flow for shockless type.
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
NO SPRING
SPOOL TYPE NORMAL
50 BAR (735 100 BAR (1470 150 BAR (2200 207 BAR (3000 250 BAR (3675 310 BAR (4500
POSITION
PSI) PSI) PSI) PSI) PSI) PSI)
N2 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
N3 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
N4 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
N40 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPRING OFFSET
SPOOL TYPE NORMAL
50 BAR (735 100 BAR (1470 150 BAR (2200 207 BAR (3000 250 BAR (3675 310 BAR (4500
POSITION
PSI) PSI) PSI) PSI) PSI) PSI)
B2 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
B3 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
B4 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
B40 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0) 500(133.0)
Northman www.northmanfp.com 49
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
PRESSURE DROP AND PERFORMANCE CURVES TEST CIRCUIT
TEST SYSTEMS
1. Tesng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. Thro le Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 140 LPM(37 GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
SPOOL PRESSURE DROP CURVE NUMBER
TYPE PA BT P B A T P T
C2 8 5 8 7
C3 6 4 6 7 6
C4 8 5 8 7
C40 8 5 8 7
C5 8 4 5 7 2
C6 5 1 5 4 3
C60 6 5 6 7 3
C7 6 5 6 7
C8 8 5 8 7
C9 8 4 5 7
D2 8 5 8 7
D3 6 4 6 7
B2 8 5 8 7
B3 6 4 6 7
B20 5 8
B2S 8 5 8 7
B3S 6 4 6 7
B20S 8 5
VISCOSITY cS t 15 20 30 40 50 60 70 80 90 100
SSU 77 98 141 186 232 278 324 371 417 464
FACTOR (G') 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
Northman www.northmanfp.com 50
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
Dimensions MOUNTING SURFACE: ISO 4401AB034A
SW G06 ** **** 10 UNIT: mm( inch)
Northman www.northmanfp.com 51
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G06 SERIES
Dimensions MOUNTING SURFACE: ISO 4401AB034A
SW G06 ** **** 10 UNIT: mm( inch)
Northman www.northmanfp.com 52
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G10 SERIES
FEATURES
• Armature operates in system oil. Impact is decreased and cushioning added, making less noise & solenoid life
is prolonged.
• Wet armature solenoid eliminates pushpin seal, reducing seal wear and leakage for longer valve life.
• Molded coil gives maximum insula3ng proper3es. They are protected by a special resin and impervious to
moisture and dirt for ease of maintenance.
• Plugin solenoid, easy to change coil.
• Change of pilot and drain can be easily accomplished by plugging or unplugging.
• Spool is designed to avoid crea3ng jet flow or turbulence under high pressure and flow.
• Indica3ng light and bolt kits are standard.
Northman www.northmanfp.com 53
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G10 SERIES
Northman www.northmanfp.com 54
SOLENOID OPERATED DIRECTIONAL VALVE
SWH-G10 SERIES
SPECIFICATIONS
Maximum opera ng pressure 207 BAR (3000 PSI)
207 BAR (3000 PSI) EXTERNALLY DRAINED
Maximum tank line back pressure
138 BAR (2000 PSI) INTERNALLY DRAINED
Opon ET
Northman www.northmanfp.com 55
SOLENOID OPERATED DIRECTIONAL VALVE
SWG10 SERIES
SOLENOID RATINGS
VOLTAGE CURRENT & POWER
COIL
ELECTRIC SOURCE SOURCE RANGE INRUSH HOLDING
TYPE Hz WATTAGE
RATED (±10%) CURRENT (A) CURRENT (A)
A24 60 AC24V 21.626.4 6.8 1.7
50 AC100V 90110 1.60 0.46
A110 60 AC100V 90110 1.40 0.32
AC110V 99121 1.50 0.39
A120 50 AC110V 99121 1.30 0.38
60 AC120V 108132 1.20 0.27
50 AC200V 180220 0.80 0.23
AC A220 60 AC200V 180220 0.70 0.16
AC220V 198242 0.75 0.19
(10 and 20 Opons) 50 AC220V 198242 0.67 0.1 9
A240 60 AC240V 216264 0.59 0.13
R110 50 AC100V 90110 0.30 0.30
60 AC110V 99121 0.30 0.30
R220 50 AC200V 180220 0.15 0.15
60 AC220V 198242 0.15 0.15
50 AC220V 180220 0.14 0.14 26
R240 60 AC240V 216264 0.14 0.14
DC D12 DC 12V 10.813.2 2.20 2.20
(10 and 20 Opons) D24 DC 24V 21.626.4 1.10 1.10
DC D12 DC 12V 10.813.2 2.60 2.60
28.8
(31 and 41 Opons) D24 DC 24V 21.626.4 1.30 1.30
TECHNICAL DATA:
• Solenoid can be used within 10% to +10% of the rated voltage of the coil.
• Withstand voltage 1500 v/sec.
• Insulaon resistance over 100MQ.
• A momentary signal of approx. 0.1 second is required for shi;ing acon.
• Pilot pressure of internally drained valves must always exceed tank port pressure by a minimum of 3.5 BAR
(50 PSI) Valve must be externally drained if there is a possibility of tank line pressure surges overcoming this
differenal.
• If the hydraulic circuit does not provide sufficient pilot pressure to shi; valves with open center spool config
uraons C3, C5, C6, do either: (1) Use the external pilot opon (“E“). Provide 140 PSI (10 Bar) minimum pilot
pressure to the “X” port on the manifold or subplate from another source in your system to shi; the valve. (2)
If the valve must be internally piloted in your system, then install back pressure of 140 PSI (10 Bar) minimum at
the tank line of the main valve. The valve must be externally drained (“T“) with this method.
PORT INTERCONNECTION
• With solenoid "b" energized PA BT.
• With solenoid "a" energized PB AT.
(But port interconnecons are reversed for C3 C5, C6 and C60 type)
ACCESSORIES:
• Mounng bolt kits are supplied with valve socket head cap screws 3/4"10UNC2Bx3" L 6 pcs for ghtening
torque 47305850 kgfcm (41005060 lbsin).
• ORing P41 90° 4 pcs and P20 90° 2 pcs.
Northman www.northmanfp.com 56
SOLENOID OPERATED DIRECTIONAL VALVE
SWG10 SERIES
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE NORMAL NO SPRING
POSITION 50 BAR (735 PSI) 100 BAR (1470 PSI) 150 BAR (2200 PSI) 207 BAR (3000 PSI)
N2 1100(292) 1100(292) 1100(292) 1100(292)
N3 1100(292) 1100(292) 1100(292) 1100(292)
N4 1100(292) 1100(292) 1100(292) 1100(292)
THE MAXIMUM FLOW RATE LPM (GPM) UNDER DIFFERENT PRESSURE BAR (PSI)
SPOOL TYPE NORMAL SPRING OFFSET
POSITION 50 BAR (735 PSI) 100 BAR (1470 PSI) 150 BAR (2200 PSI) 207 BAR (3000 PSI)
B2 1100(292) 1100(292) 1100(292) 1100(292)
B3 1100(292) 1100(292) 1100(292) 1100(292)
B4 1100(292) 1100(292) 1100(292) 1100(292)
Northman www.northmanfp.com 57
SOLENOID OPERATED DIRECTIONAL VALVE
SWG10 SERIES
TEST SYSTEMS
1. Tesng Valve
2. Pump
3. Pressure Sensor
4. Flow Sensor
5. Relief Valve
6. ThroNle Valve
TEST CONDITIONS
Pressure: 69 BAR (1000PSI)
Flow Rate: 140 LPM(37 GPM)
Viscosity: 35 cSt (175SSU)
PERFORMANCE CURVES
cS t 15 20 30 40 50 60 70 80 90 100
VISCOSITY
SSU 77 98 141 186 232 278 324 371 417 464
FACTOR (G') 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
Northman www.northmanfp.com 58
SOLENOID OPERATED DIRECTIONAL VALVE
SWG10 SERIES
Northman www.northmanfp.com 59
SOLENOID OPERATED DIRECTIONAL VALVE
SWG10 SERIES
Northman www.northmanfp.com 60
MANUALLY OPERATED DIRECTIONAL VALVE
HDG02 SERIES
FEATURES
on or a 3posion valve. Other opons include a springoffset design, or springcentered or detented.
Note: Modular pressure and flow control valves in the M**02 series that mount under this direconal control
are available separately to make a convenient control valve package.
Northman www.northmanfp.com 61
MANUALLY OPERATED DIRECTIONAL VALVE
HDG02 SERIES
Northman www.northmanfp.com 62
MANUALLY OPERATED DIRECTIONAL VALVE
HDG02 SERIES
SPECIFICATIONS
Maximum operang pressure 207 BAR (3000 PSI)
Maximum flow 63 LPM (16.6 GPM)
Northman www.northmanfp.com 63
MANUALLY OPERATED DIRECTIONAL VALVE
HDG03 SERIES
FEATURES
This industrial hydraulic fourway valve is actuated manually with the handlever. It may be ordered as a 2posi
on or a 3posion valve. Other opons include a springoffset design, or springcentered or detented.
Note: Modular pressure and flow control valves in the M**03 series that mount under this direconal control
are available separately to make a convenient control valve package.
Northman www.northmanfp.com 64
MANUALLY OPERATED DIRECTIONAL VALVE
HDG03 SERIES
Northman www.northmanfp.com 65
MANUALLY OPERATED DIRECTIONAL VALVE
HDG03 SERIES
Northman www.northmanfp.com 66
MANUALLY OPERATED DIRECTIONAL VALVE
HDG04 SERIES
FEATURES
This industrial hydraulic fourway valve is actuated manually with the handlever. It may be ordered as a 2posi
3on or a 3posi3on valve. Other op3ons include a springoffset or springcentered design.
Note: Modular pressure and flow control valves in the M**04 series that mount under this direc3onal control
are available separately to make a convenient control valve package.
Northman www.northmanfp.com 67
MANUALLY OPERATED DIRECTIONAL VALVE
HDG04 SERIES
Northman www.northmanfp.com 68
MANUALLY OPERATED DIRECTIONAL VALVE
HDG04 SERIES
Northman www.northmanfp.com 69
MANUALLY OPERATED DIRECTIONAL VALVE
HDG06 SERIES
FEATURES
This industrial hydraulic fourway valve is actuated manually with the handlever. It may be ordered as a 2posi
3on or a 3posi3on valve. Other op3ons include a springoffset or springcentered design.
Note: Modular pressure and flow control valves in the M**06 series that mount under this direc3onal control
are available separately to make a convenient control valve package.
Northman www.northmanfp.com 70
MANUALLY OPERATED DIRECTIONAL VALVE
HDG06 SERIES
Northman www.northmanfp.com 71
MANUALLY OPERATED DIRECTIONAL VALVE
HDG04 SERIES
Northman www.northmanfp.com 72
MANUALLY OPERATED DIRECTIONAL VALVE
HDT03/T06 SERIES
FEATURES
This industrial hydraulic fourway valve is actuated manually with the handlever. It may be ordered as a 2posi
6on or a 3posi6on valve. Other op6ons include a springoffset design, or springcentered or detented.
The valve is available in two body sizes with ports either 3/8” NPT or 3/4” NPT.
Northman www.northmanfp.com 73
MANUALLY OPERATED DIRECTIONAL VALVE
HDT03/T06 SERIES
Northman www.northmanfp.com 74
MANUALLY OPERATED DIRECTIONAL VALVE
HDT03/T06 SERIES
SPECIFICATIONS
Northman www.northmanfp.com 75
MANUALLY OPERATED DIRECTIONAL VALVE
HDT03/T06 SERIES
WEIGHT
MODEL A B C D E F G H J K L
KGS LBS
174 82 39 74 68 50 33 M10 68 58 92
HDT03 SERIES 4.0 8.9
(6.85) (3.23) (1.53) (2.91) (2.68) (1.96) (1.30) (3/8") (0.27) (2.29) (3.62)
258 99 41 130 120 98 66 M19 11 100 125
HDT06 SERIES 11.5 25.8
(10.16) (3.90) (1.61) (5.12) (4.72) (3.86) (2.60) (3/4") (0.43) (3.94) (4.92)
Northman www.northmanfp.com 76
INLINE CHECK VALVE
FEATURES
This inline check valve is designed to allow free flow of oil in a hydraulic system in one direc9on and block flow
in the reverse direc9on. Port sizes range from 3/8” NPT to 2” NPT.
SYMBOL
Northman www.northmanfp.com 77
INLINE CHECK VALVE
SPECIFICATIONS
MAX. OPERATED
RATE FLOW CRACKING PRESSURE
MODEL PRESSURE
LPM(GPM) BAR (PSI)
BAR (PSI)
CIT03 30(7.9)
CIT04 65(17.1)
05: 0.35(5)
CIT06 115(30.4) 207(3000)
50: 3.5(50)
CIT08 165(43.6)
CIT10 210(55.5)
PERFORMANCE CURVES
TEST FLUID VISCOSITY : 35 cSt (175 SSU)
TEST TEMPERATURE: 50C(122F)
Northman www.northmanfp.com 78
INLINE CHECK VALVE
CI-T03/04/06/08/16
C1-T10
WEIGHT
MODEL A B C D
KGS(LBS)
CIT03 70 (2.76) 26 (1.02) 3/8" 0.20 (0.44)
CIT04 82 (3.23) 29 (1.14) 1/2" 0.40 (0.88)
CIT06 91.5 (3.60) 35 (1.38) 3/4" 0.70 (1.54)
CIT08 112 (4.41) 51 (2.01) 1" 1.00 (2.20)
CIT10 132 (5.20) 65 (2.56) 11/4" 58 (2.28) 2.10 (4.62)
CIT16 159 (6.25) 80 (3.13) 2" 3.63 (8.00)
Northman www.northmanfp.com 79
RIGHT ANGLE CHECK VALVE
FEATURES
This subplate mounted check valve is designed to allow free flow of oil in a hydraulic system in one direc9on
and block flow in the reverse direc9on. It mounts on the CVM** series subplate, also shown on this page.
SYMBOL
Northman www.northmanfp.com 80
RIGHT ANGLE CHECK VALVE
SPECIFICATIONS
MAX. OPERATED
RATE FLOW CRACKING PRESSURE
MODEL PRESSURE
LPM(GPM) BAR (PSI)
BAR (PSI)
CVG03 40(10.5)
05: 0.35(5)
CVG06 125(33.0) 245 (3550)
50: 3.5(50)
CVG10 250(66.0)
PERFORMANCE CURVES
Northman www.northmanfp.com 81
RIGHT ANGLE CHECK VALVE
CVG03/06/10**10
MODEL A B C D E F G H J
CVG03 68 (2.68) 47.6 (1.87) 23.8 (0.94) 47.6 (1.87) 30.1 (1.19) 12.7 (0.50) 80 (3.15) 60.3 (2.27) 10 (0.39)
CVG06 101 (3.98) 65.2 (2.56) 32.6 (1 28) 68.2 (2.69) 40.5 (1.59) 22.2 (0.87) 114 (4.49) 80.9 (3.19) 16.5 (0.65)
CVG10 130 (5.12) 92.1 (3.63) 46.1 (1.81) 71.4 (2.81) 46.0 (1.81) 20.6 (0.81) 130 (5.12) 92.1 (3.63) 19 (0.75)
WEIGHT
MODEL K L N P Q BOLT
KGS LBS
M10x50x4PCS
CVG03 70 (2.76) 36 (1.42) 46 (1.81) 11 (0.43) 17.5 (0.69) 1.7 3.7
(3/8"x2") x4PCS
M16x55x4PCS
CVG06 81 (3.19) 38 (1.49) 54 (2.12) 17.5 (0.69) 26 (1.02) 4.1 9.0
(5/8"x21/2") x4PCS
M20x75x4PCS
CVG10 100 (3.94) 50 (1.97) 67 (2.64) 21.5 (0.85) 30 (1.18) 6.6 14.5
(3/4"x3") x4PCS
MODEL R SUBPLATE
CVG03 10.2 (0.405) GM03
CVG06 16.45 (0.65) GM06
CVG10 18.95 (0.745) GM10
Northman www.northmanfp.com 82
RIGHT ANGLE CHECK VALVE
MODEL A B C D E F G H
CVG03 90(3.54) 66.7(2.63) 11.7(0.46) 72(2.83) 42.9(1.69) 17.5(0.69) 72.5(2.85) 31(1.22)
CVG06 102(4.02) 79.4(3.13) 11.3(0.44) 93(3.66) 60.3(2.37) 21.4(0.84) 84(3.31) 36(1.42)
Northman www.northmanfp.com 83
RIGHT ANGLE CHECK VALVE
Northman www.northmanfp.com 84
PILOT CONTROLLED CHECK VALVE
FEATURES
As a pilotoperated check valve, this inline valve is designed to block the flow of oil in a line of a hydraulic sys
tem. Flow is restored by a pilot pressure signal releasing the check valve.
SYMBOL
Northman www.northmanfp.com 85
PILOT CONTROLLED CHECK VALVE
SPECIFICATIONS
RATE FLOW MAX. PRESSURE CRACKING PRESSURE
MODEL
LPM(GPM) BAR (PSI) BAR (PSI)
PCV/PCDV*03 40(10.6)
05: 0.35(5)
PCV/PCDV*06 125(33) 245(3550)
50: 3.5(50)
PCV/PCDV*10 250(66)
PERFORMANCE CURVES
Northman www.northmanfp.com 86
PILOT CONTROLLED
SOLENOID OPERATEDCHECK VALVE VALVE
DIRECTIONAL
M02 SUBPLATE
WEIGHT
MODEL A B C D E F G H J K
KGS(LBS)
80 40 150.5 75 21 64 35.5 58 41 M10
PCVT03 3.4(7.5)
(3.15) (1.57) (5.93) (2.95) (0.83) (2.52) (1.40) (2.28) (1.61) (3/8")
99.6 49.8 174 84 26 73 38 68 65 M19
PCVT06 6.0(13.2)
(3.92) (1.96) (6.85) (3.31) (1.02) (2.87) (1.50) (2.68) (2.56) (3/4")
140 70 208 104 35 92 45 84 79 M32
PCVT10 11.6 (25.5)
(5.51) (2.76) (8.19) (4.09) (1.38) (3.62) (1.77) (3.31) (3.11) (11/4")
Northman www.northmanfp.com 87
PILOT CONTROLLED CHECK VALVE
WEIGHT
MODEL A B C D E F G H J K
KGS(LBS)
80 40 150.5 75 21 64 35.5 58 41 M10
PCVT03 3.4(7.5)
(3.15) (1.57) (5.93) (2.95) (0.83) (2.52) (1.40) (2.28) (1.61) (3/8")
99.6 49.8 174 84 26 73 38 68 65 M19
PCVT06 6.0(13.2)
(3.92) (1.96) (6.85) (3.31) (1.02) (2.87) (1.50) (2.68) (2.56) (3/4")
140 70 208 104 35 92 45 84 79 M32
PCVT10 11.6 (25.5)
(5.51) (2.76) (8.19) (4.09) (1.38) (3.62) (1.77) (3.31) (3.11) (11/4")
Northman www.northmanfp.com 88
SOLENOID OPERATED DIRECTIONAL VALVE
M02 SUBPLATE
FEATURES
This singlesta1on subplate for moun1ng an industrial hydraulic direc1onal control valve conforms to the Na
1onal Fluid Power Associa1on (NFPA) D03 moun1ng pa<ern. It accepts Northman valves in the SWHG02 and
HDG02 Series. NPT and SAE Ports are available on the side or the bo<om for Pressure, Tank, A and B connec
1ons.
Northman www.northmanfp.com 89
SOLENOID OPERATED DIRECTIONAL VALVE
M02 SUBPLATE
Northman www.northmanfp.com 90
SOLENOID OPERATED DIRECTIONAL VALVE
M03 SUBPLATE
FEATURES
This singlestaon subplate for mounng an industrial hydraulic direconal control valve conforms to the Na
onal Fluid Power Associaon (NFPA) D05 mounng pa+ern. It accepts Northman valves in the SWHG03 and
HDG03 Series. NPT and SAE Ports are available on the side or the bo+om for Pressure, Tank, A and B connec
ons.
Northman www.northmanfp.com 91
SOLENOID OPERATED DIRECTIONAL VALVE
M03 SUBPLATE
M03 ** S/SB *
Northman www.northmanfp.com 92
SOLENOID OPERATED DIRECTIONAL VALVE
M03 SUBPLATE
Northman www.northmanfp.com 93
SOLENOID OPERATED DIRECTIONAL VALVE
M04 SUBPLATE
FEATURES
This singlestaon subplate for mounng an industrial hydraulic direconal control valve conforms to the
Naonal Fluid Power Associaon (NFPA) D07 mounng pa+ern. It accepts Northman valves in the SWG04 and
HDG04 Series. NPT and SAE Ports are available on the side or the bo+om for Pressure, Tank, A and B connec
ons.
Northman www.northmanfp.com 94
SOLENOID OPERATED DIRECTIONAL VALVE
M04 SUBPLATE
Northman www.northmanfp.com 95
SOLENOID OPERATED DIRECTIONAL VALVE
M06 SUBPLATE
FEATURES
This singlestaon subplate for mounng an industrial hydraulic direconal control valve conforms to the
Naonal Fluid Power Associaon (NFPA) D08 mounng pa+ern. It accepts Northman valves in the SWG06 and
HDG06 Series. NPT and SAE Ports are available on the side or the bo+om for Pressure, Tank, A and B connec
ons.
Northman www.northmanfp.com 96
SOLENOID OPERATED DIRECTIONAL VALVE
M06 SUBPLATE
Northman www.northmanfp.com 97
SOLENOID OPERATED DIRECTIONAL VALVE
M06 SUBPLATE
Northman www.northmanfp.com 98
SOLENOID OPERATED DIRECTIONAL VALVE
M10 SUBPLATE
FEATURES
This singlestaon subplate for mounng an industrial hydraulic direconal control valve conforms to the Na
onal Fluid Power Associaon (NFPA) D10 mounng pa+ern. It accepts Northman valves in the SWG10 Series.
NPT and SAE Ports are available on the side or the bo+om for Pressure, Tank, A and B connecons.
Northman www.northmanfp.com 99
SOLENOID OPERATED DIRECTIONAL VALVE
M10 SUBPLATE
MODEL C D E
M1010B 2 11/4" NPT 3/8" NPT 3/4"10 UNC