E Series Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PRODUCT CONFIGURATION

STANDARD CONFIGURATION 1
E018 = Flow Rate Monitor / Totalizer - Alarms - HART

FLOWMETER INPUT SIGNAL 2


P = Pulse input: Coil, NPN, PNP, Namur, Reed-switch

ANALOG OUTPUT SIGNAL 3


AH = Galvanically isolated, Loop powered 4-20mA output

COMMUNICATION 4
CR = HART communication
E SERIES EXPLOSION PROOF
ENCLOSURE TYPES 5
TOTALIZER & FLOW RATE INDICATOR
HAD = Diecast Aluminum Enclosure, Entry threads: 2” x
BENEFITS 1/2” NPT / 1” x 3/4” NPT
HSD = Stainless Steel Enclosure, Entry threads: 2” x 1/2”
• Save time with the easy-to-operate through glass keypad: no NPT / 1” X 3/4” NPT
need to remove the front cover nor to arrange a work permit
• Easy installation with the spacious chamber and plug and ADDITIONAL INPUTS 6
play connectors
IB = Remote input to reset total or to lock the “Clear
• Long life duration in extremely salty atmospheres (offshore) Total” button
with heavy duty stainless steel Exd enclosure
• Key information at a glance as the display shows flow rate, OUPUTS 7
total, measuring units and a flow rate indicating speedometer OT = Passive transistor output - standard configuration
FEATURES POWER REQUIREMENTS 8
• Selectable on-screen engineering units; volumetric or mass
PD-PB = 9 - 27 V (dc) + sensor supply, Lithium battery
• 7 digit flow rate / total and 11 digit accumulated total power
• 16 point linearization of the flow curve - with interpolation
HAZARDOUS AREA 9
• Power options: Loop powered, battery and 8 - 30V (dc)
XD = Explosion proof enclosure according ATEX & IECEx
• Isolated, loop powered 4 - 20mA output according to linear- (CSA and FM Pending)
ized flow rate
• Scaled pulse output according to linearized accumulated OTHER OPTIONS 10
total ZB = Backlight is included as standard
• Ability to process all types of volumetric or mass flowmeter
signals: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave 1 2 3 4 5 6 7 8 9 10
(coil), Active pulse signals. (0)4 - 20mA and 0 - 10V (dc) >>>> E112 P AH CX HAA IB OT PX-PB XD ZB
analog inputs are pending.
• HART communication

APPLICATIONS
The E018 by FLOMEC® offers you an enclosure designed to be
used in rough and tough applications, beyond being just explosion
proof. Its sturdy design and ease of use are unequaled by any other
explosion proof indicator in the market. The E018 is always your
first and safest choice in explosion proof applications.
SPECIFICATIONS
Display: External Reset Total:
Type High intensity transreflective numeric and alpha- Function: • Terminal input to reset total remotely
numeric LCD, UV resistant, with bright backlight. • If this terminal input is closed, the “clear total”
Intensity can be adjusted via keypad. function is disabled
Digits Seven 0.47” (12 mm) and eleven 0.28” (7 mm) digits. Type: Internally pulled-up switch contact - NPN
Various symbols and measuring units.
Duration: Minimum pulse duration 100ms
Refresh rate User definable: 8 times/s to 30 s.
Signal Output (Digital):
Speedometer To indicate the actual flow rate the bargraph runs
from 0 to 100% in 20 blocks, each block is 5%. Function: Pulse output. Transmitting accumulated total
Operating Temperature (Operational): Frequency: Maximum 500Hz. Pulse length user definable
between 1 ms up to 10 seconds
-40°F to +158°F (-40°C to +70°C)
Type OT: One passive transistor output (NPN) - not isolated.
Power Requirements: 300mA - 50V @ 77oF (25oC)
9 - 27V (dc). Power consumption maximum 4.2 Watt. Signal Output (Analog): 4.41”
Long life Lithium battery - lifetime depends upon settings and configura- (112 mm)
tion - up to approximately 2 years Function: Transmitting linearized flow rate
Hazardous Area - Explosion Proof: Accuracy: 12 bit. Error < 0.1%. Analog output signal can be
scaled to any desired range.
ATEX II 2 G Ex IIC T6 Gb
Certification: Type AH: Galavanically isolated, loop powered 4-20mA output
II 2 D Ex IIIC T85oC Db
Accumulated Total - 11 digits:
IECEx Ex d IIC T6 Gb
Certification Ex tb IIIC T85oC Db Units / Decimals: According5.24”
to selection for total
(133 mm)
Explosion-proof for use in Class I, Division 1, Note: Can not be reset to zero PROG
ENTER
SELECT CLEAR

FM / CSA c-us Groups A, B, C, D Flow rate - 7 digits, 0 - 1 - 2 or 3 decimals: E-Series

Certification DIP (Dust-Ignition-proof): Class II, Division 1,


Groups E, F and G. Class III, hazardous (classified) locations Units: mL, L, m3, Gallons, kg, Ton, lb, bl, cf, RND, ft3, scf,
Nm3, Nl, igal - no units
Ambient to: -40°F to +158°F (-40°C to +70°C)
Time units: /s - /min - /hr - /day
Hazardous Area - Directives:
EMC: Compliant ref. EN61326-1 and FCC 47 CFR part 15
Low voltage: Compliant ref. EN61010-1
DIMENSIONS 5.83” (148 mm)
2 x Entry thread 3/4” NPT

Signal Input (Flowmeter):


Coil / sine wave (COIL-HI: 20mVpp or COIL-LO:
80mVpp - sensitivity selectable), NPN / PNP, open
collector, reed switch, Namur, active pulse signals
8 - 12 and 24V (dc)
Frequency: Minimum oHz - maximum 7 kHz for total and flow
rate. Maximum frequency depends on signal type
and internal low-pass filter. E.g. reed switch with low-
pass filter. Maximum frequency 120Hz.
K-Factor 0.000010 - 9,999,999 with variable decimal position
Low-pass filter Available for all pulse signals

4.41”
ACCESSORIES (112 mm)
Entry thread 1” NPT
Part No. Description
FW-ABB04 1 X 3/4 inch NPT plug
FW-ABB05 1 X 1 inch NPT plug
1522068 E-Series Wall Mount Kit
5.24”
1522051 E-Series Pipe Mount Kit (133 mm)
PROG SELECT CLEAR
ENTER

E-Series

APPROVALS
5.83” (148 mm)
2 x Entry thread 3/4” NPT
Service & Warranty: For technical assistance, warranty replacement or repair contact your
FLOMEC® or GPI® distributor: In North or South America: 888-996-3837 / FLOMEC.net
Outside North or South America: +61 2 9540 4433 / FLOMEC.net

11/17 IND-1043 E Series

© 2017 Great Plains Industries, Inc. All Rights Reserved.